Preview only show first 10 pages with watermark. For full document please download

Installation Guide

   EMBED


Share

Transcript

StorCase® Technology ™ InfoStation External SCSI Expansion Chassis Installation Guide i StorCase® Technology InfoStation™ External SCSI Expansion Chassis Installation Guide Part No. D89-0000-0112 C01 August 2001 StorCase Technology, Inc. 17600 Newhope Street Fountain Valley, CA 92708-9885 Phone (714) 438-1850 Fax (714) 438-1847 InfoStation Installation Guide - Rev. C01 StorCase Technology, Inc. ii Important Safety Instructions 1. Read all these instructions. 2. Save these instructions for later use. 3. Follow all warnings and instructions marked on the product. 4. Do not use this product near water. 5. This product should be operated from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company. 6. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous voltage points or other risk. Refer all servicing to service personnel. Wichtige Sicherheitshinweise 1. Diese Hinweise sollten vollständig durchgelesen werden. 2. Diese Hinweise für einen späteren Gebrauch aufbewahren. 3. Allen auf dem Gerät angebrachten Warnungen und Hinweisen folgen. 4. Das Gerät nicht in der Nähe von Wasser verwenden. 5. Das Gerät nur mit dem Aufkleber bezeichneten Netzspannung betreiben. Bei Fragen über die Art der Netzspannung sollte der Händler oder das Energieversorgungsunternehmen zu rate gezogen werden. 6. Nicht versuchen das Produkt selbst zu reparieren. In allen Produkten existieren gefährliche elektrische Spannugen. Nicht das Gehäuse öffnen. 7. Wartungsarbeiten nur von qualifiziertern Kundendienstpersonal ausführen laßen. StorCase Technology, Inc. InfoStation Installation Guide - Rev. C01 iii Table of Contents INFOSTATION INSTALLATION ............................................................................................. 1 Installing the Drive(s) into the InfoStation ................................................................... 1 Drive Preparation .................................................................................................. 1 Removing a Drive Carrier (without a Drive Installed) ......................................... 2 Installing a Drive into the Drive Carrier ................................................................ 2 Inserting a Drive into the Chassis ....................................................................... 3 Removing a Drive from the Chassis .................................................................... 4 Removing the Blower Module ...................................................................................... 5 Removing the Power Supply Module ........................................................................... 6 Removing and Installing the I/O Repeater Module ....................................................... 7 Removing the InfoStation Access Panel ..................................................................... 8 Configuring the InfoStation for Dual-Channel ........................................................... 10 Configuring the InfoStation for 4-Channel ................................................................. 12 DXIFS-160/RAID MODULE INSTALLATION ........................................................................ 14 Installing the RAID Module into the InfoStation .......................................................... 14 Removing the InfoStation Module Option Cover Plate ............................................... 14 Installing the RAID Module into the InfoStation Chassis ........................................... 16 Replacing the RAID Controller Battery ...................................................................... 17 List of Figures FIgure 1: Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9: Figure 10: Figure 11: Figure 12: Figure 13: Figure 14: Figure 15: Figure 16: Figure 17: Figure 18: Drive Carrier ................................................................................................... 2 Drive Installation ............................................................................................. 3 Removing the Drive Carrier ............................................................................ 4 Removing the Blower Module ........................................................................ 5 Removing the Power Supply Module ............................................................. 6 Removing and Installing the I/O Repeater Module ........................................ 7 Removing the Access Panel ......................................................................... 8 Single-Channel Configuration ........................................................................ 9 Removing the I/O Blank Plate for Dual-Channel Configuration ................... 10 Dual-Channel Configuration ......................................................................... 11 Removing the I/O Blank Plates for 4-Channel Configuration ...................... 12 4-Channel Configuration .............................................................................. 13 Removing the Module Option Cover Plate ................................................... 15 Disassembling the Module Option Cover Plate ........................................... 15 Installing the RAID Module into the Chassis ................................................ 16 Removing the Battery Cover ....................................................................... 17 Unplugging the Battery from the RAID Module ........................................... 18 Removing the Battery Bracket ..................................................................... 19 InfoStation Installation Guide - Rev. C01 StorCase Technology, Inc. iv NOTICE: This User's Guide is subject to periodic updates without notice. While reasonable efforts have been made to ensure accuracy of this document, StorCase Technology, Inc. assumes no liability resulting from errors or omissions in this publication, or from the use of the information contained herein. Please check the StorCase web site at http://www.storcase.com or contact your StorCase representative for the latest revision of this document. StorCase Technology, Inc. InfoStation Installation Guide - Rev. C01 Installation 1 INFOSTATION INSTALLATION CAUTION: The InfoStation contains NO USER SERVICEABLE PARTS inside the unit. Warranty is VOID if any of the modules inside the InfoStation are opened. Refer ALL servicing to qualified service personnel! Danger of explosion if the battery is incorrectly replaced! Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer'sinstructions. WARNING: Before adding or removing DRAM modules, disconnect the battery pack from the battery back-up module. Installing the Drive(s) into the InfoStation While performing the steps in this section, work on a soft surface to prevent excessive shock to the drive(s) being installed. Also refer to the manufacturer's documentation provided with the drive(s). A #2 Phillips screwdriver will be required. Drive Preparation 1. Remove the drive from its protective packaging. 2. SCSI Drive Termination - Disable SCSI termination from the drive. Refer to the documentation provided by the drive manufacturer for the location of these terminators or jumpers. Refer to section "Termination of the SCSI Bus at the VHDCI Connectors" in the InfoStation User's Guide for further information. InfoStation Installation Guide - Rev. C01 StorCase Technology, Inc. 2 Installation Removing a Drive Carrier (without a Drive Installed) Remove the drive carrier by grasping carrier handle and pushing in the carrier release button simultaneously. Pushing in the carrier release button will unlock carrier and allow removal from the InfoStation drive bay (Figure 1 and 3). Figure 1: Drive Carrier Installing a Drive into the Drive Carrier NOTE: Before installing the drive into the carrier, the ID jumpers and spin-up option jumper on the disk drive must be removed. This is required so that the InfoStation itself can set the drive SCSI ID and spin-up option. 1. Install the drive(s) into the drive carrier(s). Drive(s) must be side-mounted into the drive carrier(s) using #6-32 screws (Figure 2). 2. After the drive(s) have been installed in to the drive carrier(s), carefully insert the carrier(s) back into the chassis. StorCase Technology, Inc. InfoStation Installation Guide - Rev. C01 Installation 3 Drive (Not Included) #6-32 Phillips Head Mounting Screw (4 total) InfoStation Drive Carrier IFS_18 Figure 2: Drive Installation Inserting a Drive into the Chassis NOTE: A new drive carrier can be inserted into an empty bay at anytime. However, the drive will not be ready for access until the following procedure is followed. 1. Press and hold the Insert/Remove button in until the Drive Ready LED starts to flash (approximately 3 seconds). 2. Drive is ready to be accessed when the Drive Ready LED glows instead of flashes. InfoStation Installation Guide - Rev. C01 StorCase Technology, Inc. 4 Installation Removing a Drive from the Chassis (Refer to section "Drive Bay Interface Panel" in the InfoStation User's Guide for further information) NOTE: Proper procedure must be followed when removing a drive from the drive bay. It is the responsibility of the User to ensure that the host does not access the drive while attempting to remove the drive, and to follow the procedure outlined below. Failure to do so may result in loss of data and/or damage to the drive itself! 1. Press and hold the Insert/Remove button in until the Drive Ready LED starts to flash (approximately 3 seconds). 2. Drive is ready to be removed when the Drive Ready LED is OFF. 3. Remove the drive carrier by grasping carrier handle and pushing in the carrier release button simultaneously. Pushing in the release button will unlock carrier and allow removal from the InfoStation drive bay (Figures 1 and 3). InfoStation Chassis IFS_19 Drive Carrier Figure 3: Removing the Drive Carrier StorCase Technology, Inc. InfoStation Installation Guide - Rev. C01 Installation 5 Removing the Blower Module CAUTION: The blower module contains NO USER SERVICEABLE PARTS inside the unit. Warranty is VOID if module is opened. Refer ALL servicing to qualified service personnel! NOTE: The blower module is hot-swappable. The chassis may remain on when removing and installing the blower module. 1. Loosen and remove the #6-32 Phillips Pan Head screw securing the blower module to the InfoStation chassis (Figure 4). 2. Remove the blower module by grasping handle and pulling out from chassis. 3. To reinstall blower module, simply reverse above mentioned steps. InfoStation Chassis IFS_20 Blower Module #6-32 Phillips Pan Head Screw (1 total) Figure 4: Removing the Blower Module InfoStation Installation Guide - Rev. C01 StorCase Technology, Inc. 6 Installation Removing the Power Supply Module CAUTION: The power supply module contains NO USER SERVICEABLE PARTS inside the unit. Warranty is VOID if module is opened. Refer ALL servicing to qualified service personnel! NOTE: The power supply module is hot-swappable. The chassis may remain on when removing and installing the power supply module. 1. Turn OFF power to the power supply module via the Power Switch located on the module itself. 2. Loosen and remove the two (2) #6-32 Phillips Pan Head screws securing the power supply module to the InfoStation chassis (Figure 5). 3. Remove the power supply module by grasping handle and pulling out from chassis. 4. To reinstall power supply module, simply reverse above mentioned steps. IFS_21 Power Supply Module InfoStation Chassis #6-32 Phillips Pan Head Screw (2 total) Figure 5: Removing the Power Supply Module StorCase Technology, Inc. InfoStation Installation Guide - Rev. C01 Installation 7 Removing and Installing the I/O Repeater Module CAUTION: Remove ALL power from the InfoStation before removing the I/O repeater module. The I/O repeater module contains NO USER SERVICEABLE PARTS inside the unit. Refer ALL servicing to qualified service personnel! NOTE: The I/O repeater module is NOT hot-swappable! Remove ALL power to chassis before removing and installing the I/O repeater module. 1. Unplug the InfoStation and verify that all cables have been disconnected. 2. Place the InfoStation on a soft clean surface to protect finish of the chassis. 3. Loosen and remove the two (2) #6-32 Phillips Pan Head screws securing the I/O repeater module to the InfoStation chassis (Figure 6). 4. Remove the I/O repeater module by grasping handle and pulling out from chassis. 5. To reinstall I/O repeater module, simply reverse above mentioned steps. IFS_22 InfoStation Chassis I/O Repeater Module #6-32 Phillips Head Screw (2 places) Figure 6: Removing and Installing the I/O Repeater Module InfoStation Installation Guide - Rev. C01 StorCase Technology, Inc. 8 Installation Removing the InfoStation Access Panel CAUTION: Remove ALL power from the InfoStation before removing the access panel(s). The InfoStation contains NO USER SERVICEABLE PARTS inside the unit. Warranty is VOID if any of the modules inside the InfoStation are opened. Refer ALL servicing to qualified service personnel! 1. Unplug the InfoStation and verify that all cables have been disconnected. 2. Place the InfoStation on a soft clean surface to protect finish of the chassis. 3. Remove the ten (10) #6-32 Phillips Flat Head screws securing the access panel to the InfoStation chassis (Figure 7). NOTE: Remove the access panel located on the RIGHT SIDE of the chassis only. 4. Remove the access panel by carefully lifting the panel(s) off the chassis (Figure 7). 5. To reinstall panel, simply reverse the above mentioned steps. Figure 7: Removing the Access Panel StorCase Technology, Inc. InfoStation Installation Guide - Rev. C01 Installation 9 Figure 8 below shows the inside of the InfoStation chassis (single-channel configuration) with the access panel removed. Figure 8: Single-Channel Configuration InfoStation Installation Guide - Rev. C01 StorCase Technology, Inc. 10 Installation Configuring the InfoStation for Dual-Channel CAUTION: Remove ALL power from the InfoStation before removing the I/O repeater module. The I/O repeater module contains NO USER SERVICEABLE PARTS inside the unit. Refer ALL servicing to qualified service personnel! 1. Unplug the InfoStation and verify that all cables have been disconnected. 2. Place the InfoStation on a soft clean surface to protect finish of the chassis. 3. Loosen and remove the two (2) #6-32 Phillips Pan Head screws securing the I/O blank plate to the InfoStation chassis (Figure 9). 4. Remove the I/O blank plate as shown in Figure 9. 5. Remove access panel (as described on page 8). 6. Remove the center jumper block so that the second I/O repeater module and terminator can be installed. Correct dual-channel configuration is shown in Figure 10. IFS_25 I/O Repeater Module I/O Blank Plate #6-32 Phillips Head Screw (2 per Plate) InfoStation Chassis Figure 9: Removing the I/O Blank Plate for Dual-Channel Configuration StorCase Technology, Inc. InfoStation Installation Guide - Rev. C01 Installation 11 Figure 10: Dual-Channel Configuration InfoStation Installation Guide - Rev. C01 StorCase Technology, Inc. 12 Installation Configuring the InfoStation for 4-Channel CAUTION: Remove ALL power from the InfoStation before removing the I/O repeater module. The I/O repeater module contains NO USER SERVICEABLE PARTS inside the unit. Refer ALL servicing to qualified service personnel! 1. Unplug the InfoStation and verify that all cables have been disconnected. 2. Place the InfoStation on a soft clean surface to protect finish of the chassis. 3. Loosen and remove the two (2) #6-32 Phillips Pan Head screws securing each I/O blank plate to the InfoStation chassis (Figure 11). 4. Remove all three (3) I/O blank plates as shown in Figure 11. 5. Remove access panel (as described on page 8). 6. Remove all the jumper blocks so that I/O repeater modules ( #2, 3, and 4) and terminators (#2, 3, and 4) can be installed. Correct 4-channel configuration is shown in Figure 12. IFS_27 I/O Repeater Module I/O Blank Plates #6-32 Phillips Head Screw (2 per Plate) InfoStation Chassis Figure 11: Removing the I/O Blank Plates for 4-Channel Configuration StorCase Technology, Inc. InfoStation Installation Guide - Rev. C01 Installation 13 Figure 12: 4-Channel Configuration InfoStation Installation Guide - Rev. C01 StorCase Technology, Inc. 14 Installation RAID MODULE INSTALLATION CAUTION: Remove ALL power from the InfoStation before installing the RAID Module. The RAID Module contains NO USER SERVICEABLE PARTS inside the unit. Warranty is VOID if module is opened. Refer ALL servicing to qualified service personnel! NOTES: The installation, configuration, and use of the RAID module option for the StorCase™ InfoStation™ chassis requires a certain level of expertise and experience on the part of the user/integrator. Since there are many configuration options and variables (ie. host platforms, applications, etc), only general guidelines will be discussed in this Installation Guide. Installing the RAID Module into the InfoStation While performing the steps in this section, work on a soft surface to prevent excessive shock to the RAID module and InfoStation chassis. Also refer to the manufacturer's documentation provided with the drive(s). A #2 Phillips and a flat blade screwdriver will be required. Removing the InfoStation Module Option Cover Plate CAUTION: Remove ALL power from the InfoStation before removing any panels or cover plates. The InfoStation contains NO USER SERVICEABLE PARTS inside the unit. Refer ALL servicing to qualified service personnel! 1. Loosen and remove the three (3) #6-32 Phillips screws securing the module option cover plate to the InfoStation chassis (Figure 13). Remove the cover plate. 2. Remove the remaining screw on the cover plate and disassemble into two pieces (Figure 14). Save the smaller section, it will be used later in Step 2 of "Installing the RAID Module into the InfoStation Chassis". 3. To reinstall cover plate, simply reverse the above mentioned steps. StorCase Technology, Inc. InfoStation Installation Guide - Rev. C01 Installation 15 InfoStation Chassis (Rear) IFS_43 #6-32 Phillips Head Screw (3 per Plate) Module Option Cover Plate Figure 13: Removing the Module Option Cover Plate Save this Section! Module Option Cover Plate IFS_44 #6-32 Phillips Head Screw (1 Place) Figure 14: Disassembling the Module Option Cover Plate InfoStation Installation Guide - Rev. C01 StorCase Technology, Inc. 16 Installation Installing the RAID Module into the InfoStation Chassis 1. Carefully slide the RAID module into the chassis and tighten screws (Figure 15). 2. Attach the smaller section of the disassembled cover plate to the module and chassis and secure with two (2) #6-32 Phillips Head screws (Figure 15). DXIFS_45 InfoStation Chassis (Rear) DXIFS-160/RAID Controller Module #6-32 Phillips Head Screw (2 Places) Figure 15: Installing the RAID Module into the Chassis StorCase Technology, Inc. InfoStation Installation Guide - Rev. C01 Installation 17 Replacing the RAID Controller Battery CAUTION: Remove ALL power from the InfoStation before uninstalling the RAID Module. The RAID Module contains NO USER SERVICEABLE PARTS inside the unit (only the battery is user serviceable). Warranty is VOID if module is opened (only the battery cover may be opened by user). Refer ALL other servicing to qualified personnel! Danger of explosion if the RAID battery is incorrectly replaced! Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. NOTE: While performing the steps in this section, work on a soft surface to prevent excessive shock to the RAID module and InfoStation chassis. 1. Remove RAID module from the InfoStation chassis by simply reversing steps in section "Installing the RAID Module into the InfoStation Chassis" (Figure 15). 2. Once module is removed, loosen and remove the two (2) screws securing the battery cover to the module (Figure 16). Remove cover. Remove These Two Screws Battery Cover SE D/ LV SI SC 60 A1 TR UL IFS_72 RAID Module Figure 16: Removing the Battery Cover InfoStation Installation Guide - Rev. C01 StorCase Technology, Inc. 18 Installation 3. Once the battery cover is removed, unplug the battery cable from the RAID module (Figure 17). 4. Carefully turn the RAID Module over to access the two (2) screws securing the battery bracket to the module (Figure 18). Loosen and remove the screws. The bracket and battery should now drop out when the RAID Module is lifted. Battery Cable 3-Cell NiMH Battery Disconnect Cable Here IFS_74 Figure 17: Unplugging the Battery from the RAID Module 5. Replace battery and install by simply reversing the above mentioned steps. MAKE SURE THAT THE BATTERY IS INSTALLED CORRECTLY! CAUTION: Danger of explosion if the battery is incorrectly replaced! Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. StorCase Technology, Inc. InfoStation Installation Guide - Rev. C01 Installation 19 Battery Bracket E D/S LV SI SC 60 A1 TR UL IFS_73 3-Cell NiMH Battery Remove These Two Screws Figure 18: Removing the Battery Bracket InfoStation Installation Guide - Rev. C01 StorCase Technology, Inc.