Installation Guide C3-series Zkaccess 5.2 Software Access Control Panels

   EMBED


Share

Transcript

Installation Guide C3-Series Access Control Panels & ZKAccess 5.2 software ZKAccess.com READER 2 BUTTON READER 1 BUTTON +12V GND WD0 WD1 GLED BEEP READER IN GND +12V BUTTON GND WD0 WD1 GLED READER BEEP IN GND +12V GND WD0 WD1 485485+ BUTTON READER 2 CARD BUTTON GLED +12V GND TX RX READER 1 READER BEEP IN GND BUTTON BUTTON IN GND IN GND READER +12V IN GND BUTTON GND EXT WD0 EXT WD1 AUX 4 GLED AUX 3 BEEP AUX 2 IN GND AUX 1 IN GND What’s in the Box 2 RUN + POWER + TX RX ACT LINK + 2 Screws & Anchors 2 Screwdriver C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE LOCK1 LOCK2 4 Diode LOCK3 LOCK4 LOCK GND 12V V- V+ NC COM NO GND SEN NC COM NO GND SEN NC COM NO GND SEN AUXOUT4 NC NO COM NC AUXOUT3 COM NO COM NC AUXOUT2 NO NO COM NC AUXOUT1 GND NO COM NC PC SEN 485-GND 1 2 3 4 5 6 7 8 485+ ON POWER CONTENT 3 What’s in the Box...................................................................... 2 Optional accessories. . ............................................................ 4 Safety Precautions................................................................... 5 Product PIN Diagram. . ........................................................... 6 LED Indicators............................................................................. 7 Product Dimension.. ............................................................... 8 Installation of Panel & Cabinet.. ..................................... 9 Wiring Legend. . ....................................................................... 10 Power Wiring Diagram . . ................................................... 11 Without Backup Battery.. ......................................................... 11 With Backup Battery................................................................. 11 Wiegand Connection.. ....................................................... 12 REX Connections................................................................... 13 Lock Connection................................................................... 14 Normally Open Lock Powered From Lock Terminal........ 14 Normally Closed Lock Powered From Lock Terminal. . .... 14 Switching Wet Contact to Dry Contact.. ............................. 15 Connecting a lock with external power supply............... 16 ZKAccess 5.2 software Installation and Setup starts at page 28 Aux. I/O connection . . ......................................................... 17 Aux. Input Connection.. ........................................................... 17 Aux. Output Connection. . ....................................................... 17 Ethernet Connection ........................................................ 18 LAN Connection........................................................................ 18 Direct connection..................................................................... 18 RS485 Connection .............................................................. 19 Restore factory setting............................................................. 20 DIP Switch Setting................................................................ 21 RS485 Address............................................................................ 21 Terminal Resistance.................................................................. 21 Typical Installation................................................................ 22 Troubleshooting.................................................................... 23 PC 485 Setting Table........................................................... 24 Electrical Specifications ................................................... 26 Specifications .......................................................................... 27 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 4 Optional accessories Wiegand Card Reader Prox Card RS485 Convertor K1-1 Exit Button Door Sensor Card Enroller Alarm C3 Cabinet C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Safety Precautions 5 The following precautions are to keep user’s safe and prevent any damage. Please read carefully before installation Do not install the device in a place subject to direct sun light, humidity, dust or soot Do not place a magnet near the product. Magnetic objects such as magnet, CRT, TV, monitor or speaker may damage the device. Do not place the device next to heating equipment Be careful not to let liquid like water, drinks or chemicals leak inside the device. Do not let children touch the device without supervision Do not drop or damage the device Do not disassemble, repair or alter the device. Do not use the device for any other purpose than specified. Clean the device often to remove dust on it. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. Contact your supplier in case of a problem. C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Product PIN Diagram SD Card Slot Ethernet Port ACT LED LINK ACT TX RX IN GND IN GND IN GND IN GND EXT 485485+ +12V GND IN GND BUTTON EXT BEEP BUTTON GLED WD1 WD0 GND READER 1 READER +12V IN GND BUTTON BEEP BUTTON GLED WD1 WD0 GND READER +12V LOCK1 READER 2 IN GND BUTTON BEEP BUTTON GLED WD1 LOCK2 WD0 GND READER +12V READER 1 IN GND LOCK3 BUTTON BEEP BUTTON GLED WD1 WD0 LOCK4 ON + + + READER 2 GND TX RX AUX 4 485+ 485-GND AUX 3 NO COM NC AUX 2 AUXOUT4 AUXOUT3 AUXOUT2 AUXOUT1 PC NC NO COM NO COM AUX 1 DIP Switches RS485 Communication NC NO COM NC SEN GND NO COM NC SEN GND NO COM NC SEN GND NO COM NC SEN GND NO COM NC LOCK CARD +12V RUN V+ POWER V12V GND 4 Aux Inputs Reserved #1 Door Exit Button #1 Door Card Reader #2 Door Exit Button #2 Door Card Reader #3 Door Exit Button #3 Door Card Reader #4 Door Exit Button #4 Door Card Reader Status LED Figure 1 485 LED 4 Aux Output 4 Lock & Door Sensor Lock Power C3 Power C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 1 2 3 4 5 6 7 8 POWER READER 6 ON TX RX TX RX RUN CARD GND IN BEEP +12V GND GLED WD1 IN BEEP GND WD0 GLED GND WD1 BEEP +12V WD0 GLED GND IN WD1 +12V GND WD0 GND IN BEEP +12V GND GLED WD1 BEEP WD0 GLED GND WD1 +12V WD0 + BEEP RUN CARD GLED WD1 GND Figure 6 CARD IN GND Flashing (POWER) Red IN LED indicates GND the panel is powered onBEEP GLED BEEP WD1 GLED IN WD0 GND WD1 GND WD0 +12V BEEP GND GLED +12V IN WD1 GND Flashing (RUN) Green LED indicated WD0 IN that panel is in normal working state GND BEEP GND GLED +12V BEEP WD1 GLED IN WD0 GND WD1 GND WD0 +12V BEEP GND GLED +12V IN WD1 GND Flashing (CARD) Yellow LED indicates that the card is read by the panel WD0 IN GND BEEP GND GLED +12V BEEP WD1 GLED IN WD0 GND WD1 GND C3-Series Access Control Panels & ZKAccess 5.2WD0 software INSTALLATION GUIDE +12V BEEP GND GLED +12V IN READER BUTTON READER LOCK2 LOCK3LOCK3 Figure 7 TX RX BUTTON READER BUTTON RUN TX RX PC RS485 (TX/RX) Flashing Yellow & Green LED indicates communication is in progress BUTTON READER BUTTON 2 READER BUTTON READER 1 1 BUTTO REAB + + + LOCK1 LOCK2LOCK2 POWER +12V TX RX READER BUTTON READER WD0 READER READER 2 POWER 485485+ IN GND IN IN LED indicates Flashing (ACT )Yellow GND GND IN progress data communication is in GND BUTTON READER BUTTON GND IN +12V GND IN IN GND GND IN GND +12V IN GND GND +12V GND 485IN 485+ GND 485485+ +12V GND IN GND IN GND READER BUTTON READER Figure 5 GND WD1 IN +12V GND WD0 IN GND BUTTON BUTTON POWER WD1 IN BEEP GND WD0 GLED GND WD1 BEEP +12V WD0 GLED LINK Solid Green LED indicates TCP/IP communication is normal BUTTON BUTTON READER BUTTON READER 1 1 BUTTON READER BUTTON 1 READER BUTTON READER 2 2 Figure 4 TX RX + + BUTT RE COM NO NO NC COM COM NO NC NC COM NO NC NO COM COM SEN NC NC GND SEN NO GND COM COM NO NC NC COM SEN NC SEN GND GND NO SEN NO COM GND COM NC NO NC COM SEN SEN NC GND GND NO SEN NO COM GND COM NC NO NC COM SEN Figure 3 + COM NO NC COM NC NO ACT + COM NC NO ACT ON + AUXOUT1 PC AUXOUT1 AUXOUT2 AUXOUT1 AUXOUT2 AUXOUT3 AUXOUT3 AUXOUT2 AUXOUT4 AUXOUT4 AUXOUT3 LOCK1 AUXOUT4 LOCK1 NO 485+ COM 485-NO NC GND ON PC 1 2 31 42 53 64 75 186 27 38 4 5 6 7 8 PC 485+ 485-485+ GND 485-GND ACT GND IN BEEP +12V GND GLED 7 EXT Figure 2 LINK GND WD1 IN +12V GND WD0 AUX 1 AUXAUX 1 2 AUXAUX AUX 2 3 1AUXAUX AUX 3 4 2AUXEXT AUX 4 3 EXTEXT AUX 4 EXT EXT LINK WD1 BEEP WD0 GLED N READER READER BUTTON BUTTON BUTTON READER READER READER BUTTON BUTTON READER BUTTON READER BUTTON READER BUTTON READER READER BUTTON LINK EADERREADER BUTTON 1 2BUTTONREADER BUTTON READER 1 2BUTTON READER BUTTON 1 READER BUTTON 2 READERREADER BUTTON 1 2BUTTONREADERREADER 1 2BUTTON LED Indicators Product Dimension 4.17in (106mm) C3-400 8.00in (203.2mm) C3-200 6.325 in (160.6mm) C3-100 6.325 in (160.6mm) 8 4.17in (106mm) 4.17in (106mm) Figure 8 C3- Metal Cabinet 11.75in (279.4 mm) 13.625in (330.2mm) Figure 9 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 3.56in (90.5mm) Installation of Panel & Cabinet 9 Cable Conduit (Punch Hole for cables) LINK AUX 1 IN GND AUX 2 IN GND AUX 3 IN GND AUX 4 +12V GND EXT ON IN GND 1 2 3 4 5 6 7 8 TX RX 485485+ IN GND BUTTON GND EXT PC 485+ 485 -TX RX AUXOUT3 NO COM AUXOUT4 NO COM BUTTON NC READER 1 GLED WD1 WD0 GND BUTTON NC SEN +12V IN GND BEEP NO COM GLED WD1 WD0 READER READER 2 LOCK1 GND NC GND SEN COM IN GND BEEP GND NO COM GLED WD1 WD0 READER READER 1 SEN GND +12V SEN IN GND BEEP NO COM NC GLED WD1 WD0 READER READER 2 LOCK4 GND BUTTON BUTTON NC LOCK POWER 12V BUTTON BUTTON NO V+ C3- Panel +12V GND NC LOCK3 + LOCK2 -- Heat Dissipation Grill BEEP NC BUTTON AUXOUT2 NO COM NC READER AUXOUT1 NO COM Power Supply ACT GND V- +12V + POWER RUN + + GND CARD Backup Battery Figure 10 Mounting Holes Figure 11 We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam cannot be found, then use the supplied drywall plastic mollies (anchors). C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Ethernet Cable RS 485 TX RX LINK ACT TX RX IN GND IN GND O TEST WE HT PUS PUS LY EK IN GND IN GND +12V GND EXT 485485+ AUX 4 485+ 485-GND IN GND EXT BUTTON BEEP BUTTON GLED WD1 WD0 GND READER 1 +12V READER IN GND BUTTON BEEP BUTTON GLED WD1 WD0 READER GND +12V LOCK1 READER 2 IN GND BUTTON BEEP BUTTON GLED WD1 LOCK2 WD0 READER GND +12V READER 1 IN GND BEEP LOCK3 BUTTON BUTTON GLED WD1 WD0 ON LOCK4 + + READER 2 + GND AUX 3 NO COM NC AUX 2 NC NO COM NO COM AUX 1 AUXOUT4 AUXOUT3 AUXOUT2 AUXOUT1 PC NC NO COM NC 1 2 3 4 5 6 7 8 ALARM SEN GND NO COM NC SEN GND NO COM NC SEN GND NO COM NC SEN GND NO COM LOCK CARD +12V NC RUN V+ POWER V12V GND EXIT No Touch FIRE ALARM PUSH Detector IR Sensor Exit Button Card Reader Exit Button Card Reader Figure 12 485 Convertor Floodlight Normally Open Lock Normally Close Lock 12V DC Power Supply 12V DC Power C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE LY EK O TEST WE HT Wiring Legend POWER READER 10 CARD Power Wiring Diagram 11 RUN + + +12V GND WD0 WD1 GLED IN GND BEEP READER READER 2 LOCK4 12V V- V+ NO + NC RUN + + + POWER TX RX LOCK GND COM BUTTON CARD +12V GND WD0 WD1 BUTTON READER 1 POWER BUTTON GLED READER BEEP IN GND +12V GND BUTTON READER 2 SEN NC WD0 WD1 GLED 485485+ BEEP +12V GND IN GND IN GND READER BUTTON ACT LINK BUTTON +12V IN GND TX RX COM NO GND SEN LOCK3 READER READER 1 GND IN GND BUTTON BUTTON GND EXT WD0 EXT WD1 AUX 4 GLED AUX 3 BEEP AUX 2 IN GND AUX 1 IN GND POWER Without Backup Battery LOCK1 LOCK2 LOCK3 LOCK4 LOCK GND 12V V- V+ NC COM NO GND SEN NC COM NO GND SEN NC COM NO GND SEN AUXOUT4 NC AUXOUT3 COM NO COM NC AUXOUT2 NO NO COM NC AUXOUT1 GND NO COM NC PC SEN NO COM NC 1 2 3 4 5 6 7 8 485+ 485-GND ON POWER 24V AC AC N L + - BT+ BT- Switching Power Supply Ground Figure 13 +12V GND WD0 GLED READER 2 CARD IN GND + + LOCK GND 12V V- READER BUTTON V+ NC COM READER 1 RUN BUTTON BEEP BUTTON +12V GND WD0 WD1 GLED READER BEEP IN GND +12V GND WD0 BUTTON LOCK4 READER 2 WD1 NO GND WD1 GLED READER BEEP IN GND +12V BUTTON BUTTON POWER POWER TX RX READER 1 GND 485485+ READER WD0 +12V GND BUTTON BUTTON WD1 IN GND SEN EXT GLED EXT BEEP AUX 4 IN GND AUX 3 IN GND NC AUX 2 IN GND COM AUX 1 IN GND LOCK3 TX RX LOCK1 LOCK2 LOCK3 LOCK4 LOCK GND 12V V- V+ NC COM NO GND SEN NC COM NO GND SEN NC COM NO GND SEN AUXOUT4 NC AUXOUT3 COM AUXOUT2 NO NO COM NC AUXOUT1 GND NO COM NC PC SEN NO COM NC 1 2 3 4 5 6 7 8 NO COM NC ON 485+ 485-GND LINK + ACT NO GND SEN With Backup Battery POWER -- + 24V AC AC N L + - BT+ BT- Switching Power Supply Ground Figure 14 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Wiegand Connection LINK ACT TX RX IN GND IN GND AUX 2 AUX 3 IN GND EXT AUX 4 IN GND BEEP BUTTON GLED PC WD1 BUTTON 485485+ +12V GND IN GND AUX 1 485+ 485 -GND TX RX AUXOUT2 AUXOUT1 BUTTON EXT BUTTON READER 1 READER C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE WD0 Figure 15 GND Wiegand Card Reader IN GND +12V Beeper BEEP Green LED GLED Wiegand D1 WD1 Wiegand D0 WD0 GND READER 1 READER +12V IN GND AUXOUT4 AUXOUT3 BUTTON BUTTON READER BUTTON BEEP LOCK1 READER 2 BUTTON GLED BUTTON WD1 LOCK2 BUTTON WD0 READER 1 READER READER GND LOCK3 BUTTON +12V GND NO COM NC NO COM NC IN GND BEEP GLED WD1 WD0 GND +12V IN GND BEEP GLED WD1 WD0 GND +12V IN GND BEEP BUTTON GLED WD1 READER 2 WD0 ON LOCK4 + + READER 2 + GND IN GND LOCK BUTTON BEEP BUTTON GLED WD1 WD0 READER GND DC+(6-14V) NO COM NC NO COM NC SEN GND NO COM NC SEN GND NO COM NC SEN GND NO COM NC SEN GND NO COM NC CARD V+ RUN V- POWER +12V 12V GND 16 or 18 AWG shielded cable recommended 1 2 3 4 5 6 7 8 12 POWER READER READER 1 TX RX LINK IN GND RX TX RX 485485+ 485485+ +12V GND BUTTON EXT EXT BUTTON BUTTON BUTTON BUTTON BUTTON READER 1 READER READER READER 1 1 LOCK1 BUTTON BUTTON READER READER LOCK2 READER 2 BUTTON READER READER 1 BUTTON READER BUTTON BUTTON BUTTON BUTTON WD1 WD0 WD0 GND BEEP GLED GLED WD1 BEEP GND +12V +12V IN GND IN GND WD1 WD0 WD0 GND BEEP GLED GLED WD1 BEEP IN GND IN GND EXTEXT IN GND IN GND +12V GND IN GND 485485+ IN GND BEEP GLED WD1 WD0 GND +12V XT ACT TX RX AUX 4 485+ 485 -GND AUX 3 NO COM NC AUX 2 NO COM NC AUX 1 AUXOUT4 AUXOUT3 AUXOUT2 AUXOUT1 PC NO COM NC IN GND BEEP GLED WD1 WD0 GND +12V IN GND BEEP GLED WD1 WD0 GND +12V IN GND LOCK3 BEEP BUTTON BUTTON GLED WD1 READER READER WD0 ON LOCK4 + + READER 2 + READER READER 2 2 GND EXIT Unused 1 2 3 4 5 6 7 8 NO COM NC SEN GND NO COM NC SEN GND NO COM NC SEN GND NO COM NC SEN GND NO COM LOCK CARD +12V NC RUN V+ POWER V12V GND GND +12V +12V IN GND IN GND BEEP BUTTON BUTTON BUTTON BUTTON BEEP GLED GLED WD1 COM GND No Touch 12V DC ( + ) 12V DC ( - ) Separate Power Supply ZK ABK Exit Button 13 REX Connections NO BUTTON PUSH K1-1 Exit Switch Figure 16 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE POWER READER REARE REA Lock Connection (Dry Contact) BUTTON IN GND BEEP GLED WD0 LOCK4 LOCK +12V BUTTON IN GND BEEP NO COM NC GLED WD1 WD0 READER READER 2 LOCK1 GND GND SEN +12V NO COM NC IN GND BEEP LOCK3 GND NO COM GLED WD1 WD0 GND +12V SEN IN GND BEEP NO COM NC GLED WD1 WD0 READER READER 2 LOCK4 GND BUTTON BUTTON NC LOCK POWER 12V READER READER 1 SEN V+ BUTTON GND BUTTON LOCK2 ETHERNET GND V- +12V + POWER RUN + + GND CARD GND Sensor Sensor - GND + 12V DC 12V DC Figure 17 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE GND POWER GND SEN 12V V- V+ NC COM NO GND SEN NC COM LOCK3 READER WD1 NO 485485+ GND SEN NC COM NO GND SEN +12V GND EXT NC IN GND EXT COM IN GND AUX 4 NO IN GND AUX 3 GND IN GND AUX 2 AUXOUT4 NO COM NC BUTTON AUXOUT3 NO COM NC READER 1 NO COM NC BUTTON NO COM NC TX RX AUX 1 TX RX AUXOUT2 LOCK2 ACT 485+ 485-GND AUXOUT1 LOCK1 PC SEN LINK 1 2 3 4 5 6 7 8 XOUT4 Connecting a Lock with External Power Supply ON COM NC 14 FR107 Diode IN G +1 G W W GL BE IN G +1 G W W GL BE IN G 48 48 +1 G IN G 15 TX RX BUTTON READER 1 BUTTON READER 2 BUTTON Switching Dry Contact to Wet Contact +12V GND WD0 WD1 GLED BEEP READER IN GND +12V BUTTON GND WD0 WD1 GLED READER BEEP IN GND +12V BUTTON GND WD0 GLED READER BEEP IN GND +12V BUTTON GND WD0 WD1 GLED READER BEEP IN GND 485485+ BUTTON WD1 Important Notes: EXT Select the appropriate lock relay and find its jumpers CARD The factory default jumper setting is set as dry mode. If you want to power the lock from BUTTON you READER 1 BUTTON 2 BUTTON the panel, must take theREADER following stepsREADER 1 BUTTON READER 2 + RUN TX RX GND XT 1 2 3 4 5 + POWER 1 2 3 4 5 1. Take off the jumpers and change to 2. Connect the lock as shown in the diagram, (see figure 20 and 21) + LINK IN GND AUX 2 IN GND AUX 3 IN GND AUX 4 +12V GND EXT 485485+ EXT IN GND BUTTON 1 2 3 4 5 6 7 8 ACT TX RX PC AUX 1 ON IN GND 485+ 485-GND TX RX BEEP GLED WD1 WD0 GND SEN +12V IN GND BEEP NO COM NC GLED WD1 WD0 READER READER 2 LOCK1 GND BUTTON BUTTON AUXOUT4 NO COM NC READER AUXOUT3 NO COM NC READER 1 AUXOUT2 NO COM NC BUTTON AUXOUT1 NO COM NC GND +12V NO COM NC IN GND BUTTON BEEP IN GND BEEP WD1 WD0 POWER LOCK GND 12V V- V+ NC COM NO GND SEN COM NO GND SEN NC COM NO NC LOCK4 POWER CARD C3-Panel 4 Lock Relays Select one Relay AUXOUT4 5 4 3 2 1 Default setting 1, 2 - 3, 4 5 4 3 2 1 LOCK1 5 4 3 2 1 Take off jumpers Jumpers Plug Jumpers 2, 3 - 4, 5 Figure 19 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE NO AUXOUT3 GND NO COM NC AUXOUT2 SEN NO COM NC AUXOUT1 NC NO COM NC PC COM NO COM NC TX RX Figure 18 485+ 485-GND 5 6 7 8 LOCK3 NO RUN LOCK2 GND + POWER LOCK1 + +12V 12V + LOCK GND V- GND AUXOUT4 GLED V+ READER NC GND +12V COM SEN GND NC WD0 SEN NO READER 2 LOCK4 GND BUTTON SEN BUTTON NC COM NO COM NC AUXOUT3 COM NO NO COM NC AUXOUT2 NO GND NO COM NC AUXOUT1 LOCK3 485+ 485 -GND WD1 PC GND SEN GLED READER READER 1 SEN NO COM NC LOCK2 GND BUTTON TX RX SEN LOCK2 BUTTON +12V GND WD0 WD1 GLED BEEP IN GND +12V GND WD0 WD1 GLED BEEP IN GND +12V PC IN GND IN GND +12V GND 485485+ LOCK1 LOCK2 BUTTON COM NO GND SEN READER 1 NC COM NO GND SEN BUTTON NC COM NO READER 2 GND NO COM NC IN GND SEN NO COM NC TX RX EXT NO COM NC AUXOUT4 ACT EXT NO COM NC AUXOUT3 485+ 485-GND AUX 4 AUXOUT2 IN GND AUX 3 AUXOUT1 1 2 3 4 5 6 7 8 PC BUTTON LINK ON 485-GND TX RX READER 1 AUX 2 485+ GND WD0 WD1 GLED BEEP IN GND TX RX (Wet Contact) BUTTON AUX 1 1 2 3 4 5 6 7 8 READ WD1 READER GLED BUTTON LOCK3 READER NC 485485+ READER BEEP +12V GND BUTTON Normally Open Lock Powered From Lock Terminal COM IN GND READER NO IN GND + BUTTON GND EXT IN GND EXT SEN AUX 4 NC AUX 3 POWER Lock Connection 16 LOCK4 TX RX +12V GND WD0 WD1 GLED BEEP IN GND +12V GND WD0 WD1 GLED BEEP NO COM 12V 12V DC GLED WD1 WD0 GND V- - +12V GND POWER RUN CARD GND 12V V- GND FR107 Diode POWER CARD V+ NC COM NO GND SEN NC COM NO IN GND READER GND GND BUTTON V+ + SEN WD0 BEEP COM + LOCK WD1 +12V NO + LOCK4 GLED GND READER 2 READER 2 IN GND READER GND BUTTON NC WD0 BEEP SEN POWER COM WD1 BUTTON COM READER 1 IN GND GLED READER BUTTON NO LOCK NO BUTTON IN GND +12V GND NC LOCK4 GND +12V GND SEN LOCK3 LOCK3 WD0 READER READER 2 COM NC LOCK2 LOCK2 WD1 BEEP NO NC BUTTON BUTTON BUTTON LOCK1 GND SEN READER 1 + GLED GND SEN NC BUTTON IN GND BEEP READER 1 NO COM NC BUTTON READER NO COM NC AUXOUT4 BUTTON NO COM NC AUXOUT3 READER AUXOUT2 BUTTON AUXOUT1 ETHERNET NO COM NC 16 or 18 AWG shielded cable recommended RUN + GND 12V DC POWER + Figure 20 + Normally Closed Lock Powered From Lock Terminal 1 2 3 4 5 6 7 8 PC AUXOUT1 AUXOUT2 NO AUXOUT3 NO AUXOUT4 NO COM IN GND IN GND IN GND +12V GND 485485+ IN GND LOCK1 LOCK2 LOCK3 BUTTON + BEEP COM NC GLED WD1 WD0 READER READER 1 GND NC SEN +12V IN GND BEEP NO COM NC GLED WD1 WD0 READER READER 2 LOCK1 GND BUTTON BUTTON ETHERNET GND SEN +12V NO COM NC BEEP LOCK3 GND NO COM COM GND +12V POWER RUN CARD GND 12V V- V+ NC COM NO GND SEN NC COM NO + GND GND + SEN WD0 12V + NC WD1 V- POWER COM 12V DC GLED LOCK NO IN GND V+ READER READER 2 LOCK4 GND GND BEEP NO NC LOCK WD0 GND BUTTON BUTTON SEN LOCK4 WD1 +12V NC LOCK3 GLED READER READER 1 SEN LOCK2 IN GND BUTTON BUTTON LOCK2 GND GND - FR107 Diode POWER GND 12V DC Figure 21 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE NC COM NO LOCK4 TX RX COM NC GND SEN NC COM NO GND SEN NC COM NO GND SEN NC COM NO GND SEN NO COM NC NO COM NC ON NO COM NC IN GND BUTTON AUXOUT4 ACT TX RX 485+ 485-GND EXT NO COM NC LINK EXT AUXOUT3 AUX 4 AUXOUT2 AUX 3 AUXOUT1 AUX 2 PC AUX 1 NO COM NC 1 2 3 4 5 6 7 8 485 -GND 485+ TX RX (Wet Contact) WD0 WD1 GLED READER BEEP IN GND +12V BUTTON GND READER WD0 485485+ BUTTON WD1 EXT GLED EXT BEEP AUX 4 IN GND AUX 3 +12V GND IN GND Aux. Input Connection IN GND AUX 2 17 IN GND AUX 1 IN GND Aux. I/O connection LINK TX RX BUTTON TX RX BUTTON IN GND BEEP GLED WD1 WD0 READER READER 1 WD0 PUS GND SEN +12V NO COM NC IN GND BUTTON BUTTON LOCK2 GND BEEP LOCK3 GND NO COM LY EK FIRE ALARM GLED WD1 WD0 GND +12V SEN IN GND GND BUTTON BUTTON NC BEEP NO COM NC GLED WD1 WD0 READER READER 2 LOCK4 LOCK POWER IN GND O TEST WE HT READER 2 READER READER 1 SEN IN GND O TEST WE HT WD1 PUS GLED AUX 4 NC READER COM AUX 3 NO 12V BUTTON LY EK IN GND BEEP READER 2 LOCK1 GND +12V BUTTON SEN V+ IN GND READER 1 GND BUTTON ETHERNET BUTTON ON GND V- +12V + POWER RUN + + GND CARD PC 485+ 485-GND +12V GND 485485+ EXT TX RX EXT 1 2 3 4 5 6 7 8 ACT IN GND AUX 2 485485+ EXT AUXOUT4 +12V GND EXT AUXOUT3 NO COM NC IN GND AUX 4 AUXOUT2 NO COM NC IN GND AUX 3 AUXOUT1 NO COM NC IN GND AUX 2 PC NO COM NC AUX 1 ON 1 2 3 4 5 6 7 8 TX RX 485+ 485-GND IN GND ACT AUX 1 LINK GND 12V DC 12V DC TX RX Figure 22 TX RX IN GND AUX 4 +12V GND EXT 485485+ GND BUTTON COM NC IN GND BEEP READER 1 NC GLED WD1 WD0 GND SEN +12V IN GND BEEP NO COM NC GLED WD1 WD0 READER READER 2 LOCK1 GND BUTTON COM NC GND SEN COM IN GND COM WD0 READER READER 1 NO GND +12V SEN IN GND GND BEEP BUTTON BUTTON NC BEEP NO GLED WD1 WD0 LOCK POWER GND V- +12V + POWER RUN + + GND CARD COM NC WD1 WD0 GND SEN 12V DC NC NO COM GLED WD1 WD0 GND & ZKAccess 5.2 software INSTALLATION GUIDE C3-Series Access Control Panels +12V BU BUT NC Figure 23 READER LOCK3 GND BEEP READER 1 SEN IN GND BUTTON COM BUTTON LOCK2 NO GND +12V GND ALARM GLED READER READER 2 NC READER READER 2 COM 12V IN GND GLED WD1 LOCK1 NC COM NO GND AUXOUT4 +12V BEEP GND V+ BUTTON BUTTON NO SEN LOCK4 NO +12V GND NC LOCK3 LOCK1 GND LOCK2 SEN AUXOUT3 BUTTON NO BUTTON AUXOUT4 BUTTON AUXOUT3 NO COM NC READER AUXOUT2 NO BUTTON AUXOUT1 AUXOUT4 ETHERNET NO COM AUXOUT2 SEN 485+ 485-GND TX RX NO COM NC WD1 AUXOUT1 WD0 GND EXT PC 485+ 485-- GLED NO COM NC AUX 3 TX RX PC NO COM NC AUX 2 IN GND NO COM NC IN GND READER IN GND ACT NO COM NC LINK ACT BEEP 1 2 3 4 5 6 7 8 READER 1 LINK IN GND BUTTON BUTTON ON AUX 1 AUXOUT3 NO COM NC Aux. Output Connection 1 2 3 4 5 6 7 8 AUXOUT2 NO COM NC ON AUXOUT1 NO COM NC 18 Ethernet Connection LAN Connection Important Notes: 1. Both 10Base-T and 100Base-T are supported. 2. This cable distance must be less than 330 ft. (100m). 3. For cable length of more than 330 ft. (100m). use HUB to amplify the signal. LINK LINK IN GND GLED WD0 GLED WD1 WD0 GND +12V IN GND BEEP NO COM NC GLED WD1 WD0 GND GND SEN +12V IN GND WD0 GND +12V WD0 12V GND IN GND BEEP GLED WD1 WD0 GND +12V GND POWER + CARD WD0 + RUN WD1 V+ + POWER V+ POWER POWER GND GLED +12V NC LOCK +12V 12V COM + V+ LOCK GND RUN CARD CAT5e or CAT6 ethernet cable recommended Figure 24 Direct connection To connect C3-Panel with a PC directly, connect both devices with a straight network cable. As the C3-Panel supports auto MDI/MDIX, it is not necessary to use a crossover type cable. ETHERNET LINK IN GND AUX 2 IN GND AUX 3 IN GND AUX 4 +12V GND EXT 485485+ EXT IN GND BUTTON 1 2 3 4 5 6 7 8 TX RX PC AUX 1 ON IN GND ACT 485+ 485-GND TX RX AUXOUT3 NO COM NC AUXOUT4 NO BUTTON COM NC BEEP READER 1 GLED WD1 WD0 GND BUTTON COM NC SEN +12V IN GND BEEP NO COM NC GLED WD1 WD0 READER READER 2 LOCK1 GND BUTTON AUXOUT2 NO NC READER AUXOUT1 USB NO COM GND SEN +12V NO COM NC BEEP LOCK3 GND NO COM WD0 GND IN GND BEEP NO COM NC LOCK V+ POWER 12V GLED WD1 WD0 GND V- +12V + POWER RUN + + GND CARD READER READER 2 LOCK4 GND BUTTON BUTTON SEN C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE WD1 +12V NC Figure 25 GLED READER READER 1 SEN CR10 Card Issuer IN GND BUTTON BUTTON LOCK2 GND READER WD1 NO READER 2 GLED V+ GND BUTTON LOCK4 NC COM SEN READER COM IN GND BEEP NO NC BEEP NO READER 2 LOCK4 GND GND BUTTON SEN IN GND BUTTON BUTTON NC +12V SEN READER COM GLED WD1 COM READER 1 NO LOCK3 LOCK3 GND READER READER 1 SEN NO NC BEEP BUTTON NC GND BUTTON COM LOCK2 NO BUTTON BUTTON LOCK2 GND READER WD1 GND READER 2 LOCK1 COM READER READER 2 LOCK1 NO BEEP SEN BUTTON NO COM NC BUTTON BUTTON IN GND BEEP SEN CR10 Card Issuer 485485+ READER AUXOUT4 +12V READER 1 NO COM NC GND GND BUTTON NO COM NC AUXOUT3 WD0 READER WD1 NO COM NC AUXOUT2 GLED AUXOUT1 BUTTON IN GND BEEP SEN NC USB +12V GND BUTTON PC EXT AUXOUT4 NO COM NC BUTTON AUXOUT3 NO COM NC READER 1 AUXOUT2 NO COM NC IN GND TX RX BUTTON AUXOUT1 ETHERNET NO COM NC IN GND EXT TX RX 485+ 485-GND TX RX IN GND EXT EXT PC 485485+ IN GND ACT 1 2 3 4 5 6 7 8 AUX 4 +12V GND AUX 4 ON AUX 3 1 2 3 4 5 6 7 8 IN GND AUX 3 AUX 2 ON TX RX 485+ 485-GND IN GND AUX 2 AUX 1 IN GND AUX 1 IN GND ACT RS TX RX ACT NC 1 2 3 4 5 6 7 8 AUXOUT3 AUXOUT1 AUXOUT4 AUXOUT2 LOCK1 AUXOUT3 AUXOUT4 LOCK2 PC COM NC SEN NO GND 485+ COM 485-NO NC GND COM SEN NC GND SEN NO NO GND COM NO NC NC COM NO COM NC NO SEN COM GND NC NO NO NO COM COM NC AUXOUT2 PC PC NC AUXOUT1 1 2 3 4 5 6 7 8 GND NO COM ON NO COM 485+ NC 485-- 6 7 8 NO COM NC ON RS485 -1 2 3 4 5 RS485 + GND 485+ 485-GND ON TX RX TX RX ACT LINK 19 LINK ACT LINK RS485 Connection LOCK1 AUXOUT1 LOCK3 A 485 #1 C3-Panel #2 C3-Panel #63 C3-Panel +12V IN GND GND IN 485GND BEEP 485+ GLED IN GND WD1 TX RX AUX 4 IN GND IN GND IN GND IN GND IN +12V GND 485IN 485+ GND IN GND IN GND EXT BUTTON AUXEXT 1 panels, but preferably 32 is recommended maximum. AUX READER 2 AUX 3 READER 1 TX RX TX RX BUTTON 3. To eliminate signal attenuation in communication cables and READER READER 2 1 BUTTON BUTTON BUTTON READER READER12 ON 1 2 3 4 5 6 7 8 MULTI C3-Panel TX RX ACT Figure 27 TX RX NO SEN COM GND NC NO 485+ COM NO 485 -COM NC GND NC SEN NO GND COM NO NO NC COM COM NC SEN NC GND NO SEN NO COM GND COM NC NO NO NO COM COM NC NC 1 2 3 4 5 6 7 8 NC GND NO COM AUXOUT2 PC NC 485 -- NO COM 485+ AUXOUT1 AUXOUT3 AUXOUT1 AUXOUT4 AUXOUT2 LOCK1 AUXOUT3 PC 485 AUXOUT4 LOCK2 AUXOUT1 LOCK1 AUXOUT2 LOCK #1 C3-Panel TX RX NO SEN COM GND NC NO 485+ COM NO 485-COM NC GND NC SEN NO GND COM NO NO NC COM COM NC SEN NC GND NO SEN NO COM GND COM NC NO NO NO COM COM NC NC 1 2 3 4 5 6 7 8 NC AUXOUT2 PC GND NO COM AUXOUT1 1 2 3 4 5 6 7 8 PC NC 485-- NO COM 485+ ON NO COM NC 485+ 485-GND ON 6 7 8 #63 C3-Panel ACT #2 C3-Panel TX RX TX RX ACT LINK #1 C3-Panel LINK RS485 -1 2 3 4 5 RS485 + GND RS BUTTON BUTTON BUTTON BUTTON BUTTON READER READER ON 1 2 3 4 5 6 7 8 PC ON x Distance: More READER EXT READER than 200 meters AUX BUTTON BUTTON 4 EXT 485 ACT LINK RS 6 7 8 NO COM NC ON RS485 -1 2 3 4 5 RS485 + GND 485+ 485 -GND x LINK ACT TX RX ACT LINK LINK suppress interference, if the bus is longer than 200 meters, set the number 8 DIP switch to the ON position. This is equivalent to a parallel connection of one 120ohm resistance between the 485+ and 485- lines. ON SINGLE C3-Panel WD0 IN GND GND +12V AUX 3 GLED IN GND WD1 AUX EXT 2 +12V IN GND GND IN 485GND BEEP 485+ AUX EXT 1 GND GLED WD1 WD1 WD0 BEEP WD0 IN GND AUX 4 BUTTON BUTTON BUTTON READER READER12 1 2 3 4 5 6 7 8 GND GLED WD1 WD1 WD0 BEEP WD0 IN GND AUX 3 READER READER 2 1 BEEP BEEP GLED IN 485IN 485+ GND AUX 2 Incorrect RS 485 connections BUTTON BUTTON BUTTON BUTTON BUTTON READER READER BEEP BEEP GLED IN IN +12V GND TX RX AUX 1 READER EXT READER +12V IN GND IN GND IN GND pair cable. RS485 communication wires should beBUTTON connected READER 1 in a bus cascade topology instead of a star topology, to achieve a better shielding effect by reducing signal reflection during communications. 2. A single RS485 bus can connect up to 63 access control AUX BUTTON BUTTON 4 EXT ON +12V IN GND IN GND IN GND AUX READER 2 AUX 3 WD0 GND GND +12V EXT BUTTON AUXEXT 1 WD0 GND GND +12V AUX 4 485+ WD1 WD0 AUX 3 485+ WD1 WD0 AUX EXT 2 TX RX AUX EXT 1 TX RX AUX 4 IN IN GND GND IN GND +12V BEEP GND BEEP GLED GLED WD1 485- AUX 3 IN IN GND GND IN GND +12V BEEP GND BEEP GLED GLED WD1 485- AUX 2 1. RS485 communication wires should be a shielded twisted WD0 IN GND GND +12V AUX 1 IN GND Important Notes: IN GND Figure 26 AUXOUT3 AUXOUT1 AUXOUT4 AUXOUT2 LOCK1 AUXOUT3 PC #2 C3-Panel AUXOUT4 LOCK2 AUXOUT1 #63 C3-Panel Figure 28 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE LOCK1 AUXOUT2 LOCK 20 RS485 Connection ON AUX 1 AUX 2 IN GND AUX 3 IN GND AUX 4 +12V GND EXT 485485+ EXT IN GND BUTTON NO NO NO NO COM BUTTON NC COM NC BEEP NC GLED WD1 WD0 READER READER 1 COM GND NC GND +12V IN GND BUTTON BUTTON COM SEN BEEP NO COM NC GLED WD1 WD0 READER READER 2 LOCK1 GND SEN +12V NO COM NC IN GND BEEP LOCK3 GND NO COM GLED WD1 WD0 GND +12V SEN IN GND BEEP NO COM NC GLED WD1 WD0 READER READER 2 LOCK4 GND BUTTON BUTTON NC LOCK POWER 12V READER READER 1 SEN V+ BUTTON GND BUTTON LOCK2 GND V- +12V GND + POWER RUN + + RS485 Terminal Resistance IN GND TX RX AUXOUT4 Restore Factory Setting GND AUXOUT3 32 485-- AUXOUT2 16 485+ AUXOUT1 8 TX RX PC 4 IN GND ACT 1 2 3 4 5 6 7 8 2 ON 1 2 3 4 5 6 7 8 1 LINK CARD Figure 29 Restore factory setting 1. If you forget the IP address of the C3 panel or the device does not work normally, you can use the number 7 DIP switch to restore C3-Panel to factory default settings. The parameters which gets reset are device IP address, communication password, gateway, and subnet mask. 2. The switch is OFF by default. When it is moved up and down for three times within 10 seconds and finally returned to OFF position, the factory settings will be restored after the access control panel is restarted. ON ON ON To reset factory settings Turn #7 switch ON and OFF ON OFF OFF 1 2 3 4 5 6 7 1 8 2 3 4 5 6 71 82 3 4 5 6 7 8 Figure 30 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Repeat process 3 times DIP Switch Setting 21 RS485 Address 1. Number 1-6 are reserved to set the device number for RS485 communication. The code is binary, and the numbering starts from left to right. When the switch is set to ON position, it indicates 1 (on); when the switch is set downwards, it indicates 0 (off ). For example, to set a device number 39=1+2+4+32, which corresponds to the binary code 111001, put number 1, 2, 3, and 6 to ON position, as illustrated below. AUX 3 AUX 4 EXT EXT IN GND IN GND +12V GND 485485+ BUTTO IN AUX 2 1 2 3 4 5 6 7 8 BUTTON TX RX 1 2 3 4 5 6 7 8 AUX 1 IN GND ON IN GND ON Figure 31 For more details, please check the table at the end of this document. Terminal Resistance 1. Number 8 is for setting the RS485 termination resistance. Putting the switch to ON TX RX ACT LINK position is equivalent to parallel connection of a 120 ohm termination resistance between 485+ and 485- lines. PC ON 1 2 3 4 5 6 7 8 = 120 ohm #63 C3-Panel Figure 32 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE AUXOUT1 NO NC NO COM GND 1 2 3 4 5 6 7 8 485+ 485-- ON AUX 22 Installation Diagram Ethernet Communication wire RS485 Network Communication wire 220/110 V Input C3 Access Control Bundle CEILING Sensor Electric Lock OUTDOOR INDOOR Exit Button Outdoor Wiegand card reader Indoor Wiegand card reader Figure 33 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Troubleshooting 23 1. How to switch four door one way to two door two way? ›› Connect four readers from reader 1 to reader 4. ›› Connect two door locks, one connected to LOCK1, another connected to LOCK3. ›› In the software configure reader 1-Indoor, and reader 2-Outdoor. Access Control Panel Type: One-Door Access Control Panel Two-Door Access Control Panel Four- Door Access Cotrol Panel Access Control Devices Add Switch to Two-Door Two way: Figure 34 2. Can we integrate IP Camera and NVR? ›› Currently ZKACCESS software supports ZKAccess’ IP Cameras and NVR ›› You can associate a camera to the door and setup a linkage for the same. 3. What does it mean when I get a “Wiegand Format Error”? ›› Your WD0 and WD1 wiring is reversed. 4. How do I connect a third party reader or a stand-alone reader to a C3 panel? ›› Connect the wiegand output to the WD0 and WD1 of the stand-alone readers on the panel’s reader port. Note: The board can only supply 12 V DC, 300mA power so an external power supply may be required. 5. What is the SD card slot used for? ›› SD card, stores transactions from the panel and creates a back up in additional to internal memory. 6. What kind of wire is recommended for the panel? ›› 16 or 18 AWG twisted shielded wire is recommended. 7. What is the default IP of the panel? ›› 192.168.1.201 8. How long is the device under warranty? ›› 1 Year from original purchase date, replacement/repair of hardware under ZK standard warranty requires an evaluation of the failed system by a ZK Technical Support specialist, and the issuance of a Technical Support RMA number. C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 24 PC 485 Setting Table Switch Setting Address No. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 2 3 4 5 6 1 2 4 8 16 32 ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF ON OFF ON OFF OFF OFF OFF ON ON OFF OFF OFF ON ON ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF OFF ON OFF OFF OFF ON OFF ON OFF OFF ON ON OFF ON OFF OFF OFF OFF ON ON OFF OFF ON OFF ON ON OFF OFF OFF ON ON ON OFF OFF ON ON ON ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF OFF ON OFF OFF ON OFF OFF ON OFF ON ON OFF OFF ON OFF OFF OFF ON OFF ON OFF ON OFF ON OFF ON OFF OFF ON ON OFF ON OFF ON ON ON OFF ON OFF OFF OFF OFF ON ON OFF ON OFF OFF ON ON OFF OFF ON OFF ON ON OFF ON ON OFF ON ON OFF OFF OFF ON ON ON OFF ON OFF ON ON ON OFF OFF ON ON ON ON OFF ON ON ON ON ON OFF OFF OFF OFF OFF OFF ON C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 25 Switch Setting Address No. 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 1 2 3 4 5 6 1 2 4 8 16 32 ON OFF OFF OFF OFF ON OFF ON OFF OFF OFF ON ON ON OFF OFF OFF ON OFF OFF ON OFF OFF ON ON OFF ON OFF OFF ON OFF ON ON OFF OFF ON ON ON ON OFF OFF ON OFF OFF OFF ON OFF ON ON OFF OFF ON OFF ON OFF ON OFF ON OFF ON ON ON OFF ON OFF ON OFF OFF ON ON OFF ON ON OFF ON ON OFF ON OFF ON ON ON OFF ON ON ON ON ON OFF ON OFF OFF OFF OFF ON ON ON OFF OFF OFF ON ON OFF ON OFF OFF ON ON ON ON OFF OFF ON ON OFF OFF ON OFF ON ON ON OFF ON OFF ON ON OFF ON ON OFF ON ON ON ON ON OFF ON ON OFF OFF OFF ON ON ON ON OFF OFF ON ON ON OFF ON OFF ON ON ON ON ON OFF ON ON ON OFF OFF ON ON ON ON ON OFF ON ON ON ON OFF ON ON ON ON ON ON ON ON ON ON ON C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 26 Electrical Specifications Maximum Typical Minimum Notes WORKING POWER SUPPLY Voltage (V) 9.6 12 Current (A) 14.4 Use regulated DC power adaptor only 2 ELECTRONIC LOCK RELAY OUTPUT Switching voltage (V) 12V Switching Current (A) 2 Use regulated DC power adaptor only Auxiliary relay output SWITCH AUX. INPUT VIH (V) TBD VIL (V) TBD Pull-­up resistance (Ω) 4.7k The input ports are pulled up with 4.7k resistors WIEGAND INPUT Voltage (V) 10.8 12 Current (mA) 13.5 500 ZK ELECTRONIC LOCK Voltage (V) Current (mA) 10.8 12 13.2 500 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Specifications 27 Communication RS485, TCP/IP Baud Rate for RS485 9600-15200 Power Supply 12V DC, 2A Card Holders Capacity 30,000 Log Events Capacity 100,000 LED Indicator Indicator for communication, power, status and prox card Environment 32-113 °F (0-45°C) Operating Humidity 20% to 80% Number of doors controlled Four Door (four door one way and two door two way) Number of readers supported 4 Types of readers supported 26-­bits WIEGAND, others upon request Number of Inputs 12 (4 Exit Device, 4 Door Status, 4 AUX) Number of Outputs 8 (4- Form C relay for lock and 4- Form C relay for Aux output) Weight 7.8lbs (3.55kg) Enclosure Stainless Steel Mounting Wall Mount Dimensions (Bundle Only) 15.7in. x 3.56in. x 13.0in 400mm(L) x 90.5mm(W) x 330mm(H) Dimensions (Board Only) 8.0in. x 4.17in. 203.2mm(L) x 106mm(W) CPU 32 bit 400MHz RAM 32MB Flash 128MB Certified C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 28 ZKAccess 5.2 software Installation & Setup Content Downloading..................................................................................................................29 Installation.........................................................................................................................30 Adding a Device...........................................................................................................31 Creating a Time Zone. . ..............................................................................................32 Create an Access Level.............................................................................................33 Enrolling Personnel. . ................................................................................................. 34 Add & Delete Personnel to Access Level....................................................36 Real Time Monitoring. . ..............................................................................................37 Exporting Reports. . ......................................................................................................38 Passage Mode / First Card Normal Open ..................................................39 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Downloading 29 2 1. Go to zkaccess.com. 2. Click Downloads and then Software Downloads in the dropdown menu. 3 3. Scroll to the bottom of the page and click ZKACCESS 5.2.22 to download. If you do not have software to extract compressed files, Scroll up on the same page to find Winrar 32 or Winrar 64 to download. 4. Extract the downloaded files to a new folder named “ZKAccessSetup” 5. Click setup.exe to begin installation. 5 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 30 Installation 1 2 1. Add an open port (Default 80) or ask a network administrator for an open port 2. Click the box to “Add firewall exception for this port” 4 3 3. Click Browse and choose or create a folder to store your backup files in. 4. Click OK C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Adding a Device 31 1 3 2 1. Click Device 2. Click Search Panels , to show the Search interface; 3. Click Search , and it will prompt [searching……]; 7 5 4. After searching, the list of all access control panels on the network will be displayed. 5. Click Add Device on the right side of the listed device, and a dialog box will open. 6. Enter self-defined device name, and click OK to complete the process. The default IP address of the access control panel may conflict with the IP of another device on the network. 6 7. You can modify the IP address: Click Modify IP Address to the right of the device and a dialog box will open. Enter the new IP address and other parameters. Note: Must configure the gateway and IP address in the same network segment. C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 32 Creating a Time Zone 1 1. Click Access Control > Time zones > Add to access the time zone setting interface 2 2. After setting the time zone, click OK to save, and the time zone will appear in the list. C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Create an Access Level 1 1. Click Access Control > Access levels > Add to add an access level. 2 3 2. Set parameters: access level name (no repetition), access control time zone, door combination 3. Click OK to complete setting and quit, and added access levels will appear in the list. C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 33 34 Enrolling Personnel 1 1. Click Personnel > Personnel > Add to show personnel profile edit interface. 2 3 4 5 6 7 C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 35 2. Personnel No.: By default, the length can not exceed 9 digits A number with a length of less than 9 digits will be preceded with 0 automatically to complete 9 digits. Numbers can not be duplicated. 3. Card number: You can add a card number through manual entry or a card issuer. In Actual Card Number mode (by default), you must enter both the actual card number and the site code, then the software converts the numbers to the internal card number for access control system verification. In Internal Card Number mode, enter the numbers directly. 4. Password: Set personnel password to use on a keypad reader. Password must be 4 to 6 numbers long. 5. Department: Select from the pull-down menu and click OK . If the department was not set previously, you can only select the default Company Name department. 6. Register Fingerprint: Enroll the Personnel Fingerprint or Duress Fingerprint. If the person presses the Duress Fingerprint, it will trigger the alarm and send the signal to the system. 7. Access Level: Click the box next to the access level you would like to add the personnel to. (Optional) C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 36 Add & Delete Personnel to Access Level 1 1 3 3 1. Click Access Control > Personnel Access Levels to show current access levels and personnel. Click Add personnel to open the add personnel interface. 2 2 2. Select personnel to create the list on the right, and click OK to complete adding, and added personnel will appear in the list on the right. 3. To delete personnel, select personnel and click Delete from access level . C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Real Time Monitoring 37 1 2 3 1. Click Access Control > Real-Time Monitoring to watch a live log of device transactions. 2. Click the Filters to limit which device transactions show up or view all devices at once. 3 3. Hover over a Door Icon to open pop up menu and click Remote Close , Remote Open , or Cancel Alarm . C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE 38 Exporting Reports 1 2 3 1. Click Access Control > Reports to see a report of transactions from devices. 2. Filter by time, date, personnel, or device. 3. Click Export Report to open export menu. 4 4 4. Choose a file type and click Export . C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Passage Mode / First Card Normal Open 2 39 2 The Passage Mode feature will keep a door unlocked during a specified time zone. It will automatically unlock at the beginning of the time zone and will lock automatically at the end of the specified time zone. 1. Create a new time zone with the hours you want the door to be unlocked. 2. In Door Configuration, Click Edit to the right of the door you want to change settings on. 3. Click the dropdown menu titled “Door Passage Mode Time Zone” and select your new time zone. Click OK The First Card Normal Open feature will keep a door unlocked during a specified time zone when triggered by specified personnel. After a specified personnel swipe unlock at the beginning of the time zone and will lock automatically at the end of the specified time zone 1. Create a new time zone with the hours you want the door to be unlocked. 2. In Door Configuration, under First-Card Normal Open, click Set . 3. Under First-Card Normal Open Settings, click Add . 4. Click the drop down menu titled Time Zones and choose your new time zone. Click OK 5. To add the personnel that will trigger the door to stay normal open, click Add an opening person 6. Click the check box next to the personnel and they will be added to the Selected Personnel list. Click OK Design and Specifications subject to change without notice. © 2014 ZKTeco and its subsidiaries. C3-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE Version: March 2015 ZKAccess - a division of ZKTeco