Installation Guide For Vdr Interface H2049a Mounting Og Vdr

   EMBED


Share

Transcript

Installation Guide for VDR Interface H2049A Jumper settings +6 dB 0 dB VDR Interface RT2048 -6 dB Terminal strip to VDR OUT + GND GND OUT - to VDR Factory fitted cable Factory fitted cable (1.2 metres) VDR signal specifications: Audio signal 600 ohm, combined Rx & Tx Balanced signal Galvanically isolated Level 0 dBm Level adjustable by jumper: +6 dB, 0 dB, -6 dB 40743 Mounting og VDR Interface H2049A 45.5 Drilling plan 12 67.25 104.5 4 x ø4.7mm 196 9.7 176.6 38419 TT97-125613-A Thrane & Thrane A/S • [email protected] • www.thrane.com