Transcript
PO Box 940 BLACKWOOD SA 5051 www.automationdistributors.com.au
Installation Instructions for Omni Z-Wave Interface Plugin for Vera Controllers – UI7 Serial Connection for Leviton Automation Controllers Thank you for downloading the Omni Z-Wave Interface Plugin. These instructions outline how to connect a Vera 3 Controller running User Interface Version 7 to a Leviton Automation Controller. These instructions are also suitable for the Vera Lite and Vera Edge running User Interface Version 7. This manual does not provide instructions on how to pair your Z Wave devices to the Vera. The Plugin provides two way instant feedback and control (activation license required) of Z Wave dimmers, relays, appliance plugs, roller shutters and door locks from a Leviton Omni automation board.
1.
What’s Required
The following items are required: 1 x Vera Controller 1 x USB to DB9M cable 1 x DB9M to RJ12 cable 1 x Ethernet Cable 1 x Plugin Activation Key 1 x Omni Automation Board
2.
Connecting the Hardware Before powering on the Vera 3 Controller (“Vera”) connect the USB cable to the bottom USB port on the Vera, connect the Ethernet cable between the WAN port of the Vera and your home network and connect the DB9M to RJ12 cable to the USB cable and a spare serial port on the automation controller (use serial port 2-5). You can now power on the Vera. Your Vera is ready when the Power, WAN & Wi-Fi lights are solid green. USB port 1 light will also be solid green. It may take up to 15 minutes whilst the Vera upgrades the firmware to the latest version which is part of the initial power up process of the Vera. Do not power off the Vera during this period.
Training | Sales | Support 1300 303 386
3.
Setting up the Vera for the first time Open a web browser and go to https://home.getvera.com/users/login Select “I have a new gateway to setup!”.
Scroll to the bottom of the Terms and Conditions, tick the acceptance button and press Next. Select your appropriate Vera controller (in this case Vera 3).
Select the controller from the list.
The controller will then check for any firmware updates. Press Next.
Installation Instructions for Omni Z-Wave Interface UI7 – Serial Connection. V1.1
Page 2
Once complete you will be asked to create your new login account to the Vera Portal and press “Next”
Once the firmware has been applied press “Go to Controller”.
You will be directed to the main Portal dashboard. Select “Complete Setup” which will take you to the User Interface of the Vera.
Installation Instructions for Omni Z-Wave Interface UI7 – Serial Connection. V1.1
Page 3
4.
Installing the Plugin Select “Apps” and then “Install Apps” in the left hand menu. On the right hand side type “Omni” in the Search bar and press “Search app”.
You will see the Omni Z Wave Plugin logo and the Description “Omni Z-Wave Interface”. Press the “Details” Button. On the next screen press the Install Button and Press “OK” to confirm the installation.
Once installed click on the “Devices” Tab. You may need to refresh your browser and press the Devices Tab on the left side. You will see the Omni Z-Wave Interface Device. The Main screen shows the version number and the status of the Plugin. If it is “Deactivated” the Plugin will not provide any control or feedback. In order for the Plugin to work you must enter an Activation Key (see section 6 below).
Installation Instructions for Omni Z-Wave Interface UI7 – Serial Connection. V1.1
Page 4
5.
Setting up the Plugin Click on the arrow on the right hand side of the Omni Z-Wave Interface Dashboard (shown in the picture above) and it will open the Omni Z-Wave Interface Setup page. It will say “Deactivated” and the Activation Key will be blank.
This screen allows you to configure the Interface for your Activation Key. Do not add any details in the IP Address or Port Number boxes (this function is for future releases), these must remain blank. Only the Activation Key should be entered on this screen.
6.
Obtaining & Entering your Activation Key In order for the Plugin to operate and provide communications to and from the Leviton automation controller it must be activated. To activate the Interface you will need to obtain a unique Activation Key. Open a new web page and navigate to http://license.automationdistributors.com.au and you will be taken to the Automation Distributors Australia’s License Portal Website. Click on the “Omni Z-Wave Interface logo.
You are required to add your Controller Serial Number. If you noted it from above add it in, otherwise it can be located on the outside of the box your Vera came in otherwise it can be found under Users & Account Info -> Unit Settings. It is shown as “Application ID”. You cannot proceed further without adding Installation Instructions for Omni Z-Wave Interface UI7 – Serial Connection. V1.1
Page 5
in a serial number. Please ensure you have entered your Serial Number correctly or your Activation Key will fail to activate the Vera.
Press the Purchase Button and you will see a notification at the top the screen saying “Success you have added the license to your shopping cart.”
7.
Create a Login Account In order to obtain a license you must first register an account. This enables you to use your Coupon and allows us to e-mail you your Activation Code to you. If you have not previously registered click the “Register” button on the left hand side or the “Create an Account” option on the top right of the website. Otherwise you can select Login and enter your credentials. Remember to choose your appropriate Customer Location. Fields with an “*” are mandatory fields. All other fields are optional. Please read the Terms and Conditions, tick the box to confirm you have read them and press “Continue”.
Installation Instructions for Omni Z-Wave Interface UI7 – Serial Connection. V1.1
Page 6
8.
Redeeming a Coupon If you have a Coupon to redeem as part of your purchase, press the “Shopping Cart” Menu at the top of the web page option first to enter your unique Coupon code. Once applied you can then proceed to Checkout.
9.
Completing the Purchase To complete the purchase press the Checkout menu button at the top and follow the steps to complete checkout and payment. Once you have checked out and we receive confirmation of payment, we will email to the address you supplied in your login details your Activation Key. When you have received your Activation Key go back to your Vera page . Return to the Omni Z-Wave Interface Setup Page and enter the Activation Key number including the dash into the New Activation Key field. When you press the “Set” button, if the Activation Key is valid for your Vera, the Status will change to Activated.
Press the Back button and you will be taken back to the Devices page. You will notice that the Interface front page will also say Activated.
Installation Instructions for Omni Z-Wave Interface UI7 – Serial Connection. V1.1
Page 7
10. Linking the Plugin to the Serial Port You now need to link the Serial Port to the Omni Z-Wave Interface. Press the “Apps” tab, then click on “Develop Apps” and select “Serial Port Configuration”.
In the “Used by Device” drop down box select Omni Z Wave Interface. Then press the “Reload Luup” Button. Congratulations!! You have set up the Controller to send and receive Z Wave commands and provide feedback to your Leviton automation controller. The next step is to get the Automation Controller to send the commands to the Vera. Before configuring PC Access you will need to pair your Z Wave modules to the Vera. Please refer to the Pairing Z Wave Modules to the Vera 3 which can be found on the ADA Website.
11. Configuring PC Access Open the PC Access client file and in the left hand navigation bar select Expansion -> Serial. Select a spare serial port and change it to “ZWave”. Leave the baud rate at 9600.
11.1 Dimming, Relay, Roller Shutter Modules and Power Point Plugs Select Units and change the House Code Format to Vizia RF Z-Wave. To link the modules add the Device number of the module into the Address/Node column. To locate the device number go into the module within Vera, Press the right hand arrow and scroll down and press “Advanced”.
Installation Instructions for Omni Z-Wave Interface UI7 – Serial Connection. V1.1
Page 8
Save your PC Access file and upload it to the automation board. Congratulations!! You are all set up and you should now be able to control your Z Wave modules. Do not use the first unit number of each group of 8 (eg Unit 1, 9, 17, etc). This is used for scene controllers and your devices will not function.
11.2 Access Control In PC Access select Access Control from the left hand menu. Change the On the Reader row click on the Device Type and change the device type to Z Wave and add in the Device number of your lock.
Installation Instructions for Omni Z-Wave Interface UI7 – Serial Connection. V1.1
Page 9