Preview only show first 10 pages with watermark. For full document please download

Installation Instructions Important Safeguards Save These

   EMBED


Share

Transcript

INSTALLATION INSTRUCTIONS 1 LOW PROFILE SCONCE™ LPS SERIES – SEMI-RECESSED MOUNT – REMODEL CONSTRUCTION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL CIRCUITS BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE. SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING ORIENTATION, OR MOUNTING RESTRICTIONS. SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS 1. Back out screw(s) at bottom or side of housing until baseplate can be easily removed. 2. Remove back-box. Back-box Back-box Screw 3. Cut a rectangular hole on the wall (recommended hole size 3-3/8" × 9"). 4. Drill four (4) 5/16" holes. Use the back-box as a template to mark pilot holes. Wall Wall 9.000 3.375 2.000 9.750 5/16" Dia. Cutout www. kenall.com P: 800-4-Kenall F: 847-360-1781 1020 Lakeside Drive Gurnee, Illinois 60031 LPS_F-5295_022714 INSTALLATION INSTRUCTIONS 2 5. Mount Back-box. Insert the back-box into the cutout making sure that the hooks are pointing up. Attach back-box using 1/4-20 screws and nuts (supplied by others). Remove knockouts as needed. Note: Remember to use non-ferrous hardware when installing MRI fixtures. Back-box 1/4 20 Screws (supplied by others) 6. Install back mounting brackets. a-b. Insert back mounting bracket as shown below. c. Slide bracket towards the wall and tight thumb screw. d. Break metal tab by twisting it back-and-forth. Repeat these steps to install the second bracket. Back Mounting Bracket t ke Thumb Screw www. kenall.com P: 800-4-Kenall de Sli ac Br F: 847-360-1781 1020 Lakeside Drive Gurnee, Illinois 60031 LPS_F-5295_022714 INSTALLATION INSTRUCTIONS 3 7. Make electrical connections. Disconnect facility power to the electric power supply leads. Connect fixture leads to power supply leads using connectors suitable for the gage and number of wires being used (not included). MRI Fixtures: a. Run the 24VDC supply from the EMI filter to the luminaire(s) using at least 18 AWG wires. Class 1 wiring is required. Make sure wiring is completely enclosed in grounded conduit. Any gaps, regardless of size, must be closed or wrapped in copper foil tape. Special attention should be paid to the wiring entry point into the shielded space. b. If a 0-10V dimmer is to be connected, install at this time. Dimmer must be installed outside the shielded MRI environment with an intermediate MRI room EMI filter to the luminaires. Kenall recommends using a Leviton® lllumaTech™ IP710 series dimmer or Grafik Eye GRX-TVI control interface. Contact Kenall for suitability of using an alternate sink-type 0-10V dimmer. NOTES: To prevent MRI machine interference, all DC power and dimming signal wiring must be completely shielded within grounded conduit and a suitable MRI room EMI filter must be installed on each line. 8. Install fixture. Top of housing over top of back-mounting-box's hooks. 9. Tighten screw at bottom of housing. Screw CUSTOMER SERVICE For technical assistance, call 1-800-4KENALL (1-800-453-6255). WARRANTY This product is warranted by Kenall to be free of defects in workmanship and materials for a period of one year from the date of invoice. LED lamps and internal power regulation components are warranted for a period of five years from the date of the invoice against defects in materials and workmanship. Kenall reserves the right to issue credit, repair, or replace the defective merchandise, at its discretion, upon notification and confirmation by its local representative of the defect. Kenall also reserves the right to examine the defective product if the defect is questionable and to deny the warranty herein for any product altered, improperly installed, or installed in applications for which it is not intended. Kenall assumes no responsibility for labor or freight costs incurred in connection with the installation, removal, or replacement of products determined to be defective or any other consequential or incidental damages arising from the use of the product. Kenall’s entire liability on any claim of loss or damage resulting from a defective product is limited to the replacement price of the product. The foregoing warranty is exclusive of all other warranties and no other warranties of any kind are expressed or implied. www. kenall.com P: 800-4-Kenall F: 847-360-1781 1020 Lakeside Drive Gurnee, Illinois 60031 LPS_F-5295_022714