lumenfacade™ INSTALLATION INSTRUCTIONS drawing number 111924 This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. ! ! WARNING ! SEPARATION OF FIELD INSTALLED POWER LIMITED CIRCUIT (DIMMING/CONTROL) WIRING FROM THE BRANCH CIRCUIT WIRING IN THE OUTLET BOX ARE TO BE MADE IN ACCORDANCE WITH LOCAL AND/OR NATIONAL ELECTRICAL INSTALLATION CODES. WARNING WARNING ! DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED. DISCONNECT POWER BEFORE INSTALLING OR SERVICING TO AVOID ELECTRICAL SHOCK. ! HORIZONTAL WHITE & STATIC COLORS, COLOR CHANGING & DYNAMIC WHITE WARNING CAUTION DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE. UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY. ASYMMETRIC WALLWASH OPTIC OPTION WALL RECOMMENDED SETBACK FROM WALL IS 1/10 OF THE WALL HEIGHT. NOTICE ALWAYS POSITION FROSTED SIDE TOWARD THE WALL. TOP VIEW EXAMPLE: 2FT SETBACK FOR A 20FT WALL FRONT VIEW RIGHT SIDE VIEW (Fixture pointing upwards) STEP 1. SLIDE IN UMAS MOUNTING BRACKETS STEP 2. TIGHTEN SET SCREWS 4X STEP 3. SCREW ONTO MOUNTING SURFACE 3 " 4 [19mm] 3 " 8 [10mm] ! CAUTION DO NOT LOOK INTO BEAM. LOOSEN SCREWS SLIGHTLY TO ADJUST LIGHT BEAM ORIENTATION AND RE-TIGHTEN TO SECURE Ø 9" 32 [7mm] ! 21" 13" 2 4 [45mm] [64mm] WARNING USE 1/4” FASTENERS (4X BY OTHERS) THAT ARE APPROPRIATE FOR USE WITH YOUR MOUNTING SURFACE 2X OR STEP 1. SLIDE IN WAMH MOUNTING BRACKETS STEP 2. TIGHTEN SET SCREWS 4X STEP 3. SCREW ONTO MOUNTING SURFACE 1 " 16 [27mm] 1 9 " 32 [7mm] ! CAUTION DO NOT LOOK INTO BEAM. 3 1 4 " 2 2 " [45mm] [64mm] 1 ! WARNING USE 1/4” FASTENERS (4X BY OTHERS) THAT ARE APPROPRIATE FOR USE WITH YOUR MOUNTING SURFACE LOOSEN NUTS & BOLTS SLIGHTLY TO ADJUST LIGHT BEAM ORIENTATION AND RE-TIGHTEN TO SECURE bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse. ™ Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. p.1/2 2017.03.30 MS - R4 Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenpulsegroup.com Copyright © Lumenpulse 2017 Confidential and proprietary Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See http://www.lumenpulsegroup.com/support/downloads for current data and instructions. lumenfacade™ INSTALLATION INSTRUCTIONS drawing number 111924 HORIZONTAL WHITE & STATIC COLORS, COLOR CHANGING & DYNAMIC WHITE This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. ! OR STEP 1. SLIDE IN UMP MOUNTING BRACKETS STEP 2. TIGHTEN SET SCREWS STEP 3. SCREW ONTO MOUNTING SURFACE 3 4" [19mm] 3 8" [10mm] ! USE 1/4” FASTENERS (4X BY OTHERS) THAT ARE APPROPRIATE FOR USE WITH YOUR MOUNTING SURFACE 4X *UMP BRACKETS CAN BE ADJUSTED HORIZONTALLY. WARNING STEP 4. CONNECT LEADER AND JUMPER CABLE 27" 8 [73mm] 9 32 " [7mm] 31" 2 [89mm] STEP 5. PUT SEALING CAP ON UNUSED CONNECTOR JUMPER WARNING ! INPUT CONNECTOR PLACE SEALING CAP OVER PANEL MOUNT CONNECTOR. NO PART REMOVAL REQUIRED. LEADER CAUTION 1 SEALING END CAP PROVIDED WITH EACH LEADER CABLE « clic k» » « click ONCE CABLE IS CONNECTED, TURN COLLAR 1/4 TURN CLOCKWISE TO SECURE INSTALLATION. (CLICK SOUND WILL OCCUR). CAUTION ENGAGE AND TURN COLLAR 1/4 TURN CLOCKWISE TO SECURE END CAP INSTALLATION. (CLICK SOUND WILL OCCUR). WIRING DETAIL AT JUNCTION BOX (BY OTHERS) LUMENTALK (for 2, 3 or 4’ fixture lengths [0.6, 0.9 or 1.2m]) NON-DIMMING 0-10V DIMMING DALI DIMMING LUTRON® ECOSYSTEM® ENABLED DIMMING *Lumentalk Data Bridge required for 1' [0.3m] fixture lengths see Lumentalk Data Bridge installation instructions for more details From third party controller (dimmer, DALI controller, or Lutron® EcoSystem® controller) To fixture Power input To fixture Line Ground Neutral Wire-nuts (by others) Junction box (by others) Power input (control over power line via Lumentalk system) To Lumentalk Data Bridge (for run lengths with 1' [0.3m] fixtures) Junction box (by others) Line Ground Neutral Wire-nuts (by others) American Color Code CE Color Code USE Green Black White Red/ Purple Orange Yellow/Green Brown Blue Black Grey Ground Live 100-277V Neutral 0-10V / Data + 0-10V / Data - Data + Data Power input Junction box (by others) To fixture Line Ground Neutral Wire-nuts (by others) DMX/RDM *see CBX installation instructions for more details STEP 6. CONNECT LEADER CABLE TO J-BOX 1/2” NPT LIQUID TIGHT STRAIN RELIEF (BY OTHERS) RT V sil DMX/Data Cable Specification DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance. Combined Power & Data Cable Specification Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant. NOTICE ico ne RECORD THE LOCATION OF EACH FIXTURE BY SERIAL NUMBER TO PREPARE FOR THE COMMISSIONING PROCESS (DMX/RDM). TYPICAL UMAS INSTALLATION TYPICAL ETE INSTALLATION ETE INPUT CABLE 6 " MINIMUM COIL [152mm] DIMENSION ETE LEADER CABLE (ORDER SEPARATELY) TYPICAL WAMH INSTALLATION TOP VIEW 1" MINIMUM 4 [7mm] SPACING TYPICAL UMP INSTALLATION bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse. ™ Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. p.2/2 2017.03.30 MS - R4 Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenpulsegroup.com Copyright © Lumenpulse 2017 Confidential and proprietary Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See http://www.lumenpulsegroup.com/support/downloads for current data and instructions.