Preview only show first 10 pages with watermark. For full document please download

Installation Instructions - Pendant Stem Mount Pdf

   EMBED


Share

Transcript

cylinder INSTALLATION INSTRUCTIONS PENDANT STEM MOUNT DEEP AND FLAT CANOPY LACYM - MEDIUM LACYL - LARGE drawing number 133065 This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. ! WARNING ! ! Do not exceed fixture specified voltage. WARNING ! WARNING ! Do not install if fixture, parts or connectors are damaged. Disconnect power before installing or servicing to avoid electrical shock. ! WARNING Do not attempt to clean reflector with cleaning agent or paper towels or cloth. This will permanently damage the reflector. CAUTION Unauthorized field repairs or modifications will void warranty. Tampering with power supply, factory wiring or hardware will void warranty. ! ! WARNING Separation of field installed power limited circuit (dimming/control) wiring from the branch circuit wiring in the outlet box are to be made in accordance with local and/or national electrical installation codes. ! WARNING WARNING Products are rated for an ambient of 30 °C [86 °F]. CAUTION This luminaire is not suitable for fire-rated installations. CAUTION CAUTION Interior use only. The product must only be installed in the applicable zone according to national regulations. Any damaged or cracked protective shield must be replaced to ensure IP rating is maintained. CAUTION Product must be installed with provided Lumenalpha power supplies and housings only. Use of other manufacturers' components will void warranty. Do not install upside down or horizontally. AS DELIVERED Always wear clean latex or cotton gloves when handling the reflector and mounting mechanism. Marks left on the reflector will reduce light output and cause damage not covered by the manufacturer’s warranty. LUMINAIRE MOUNTING KIT: REQUIRED TOOL: PHILLIPS SCREWDRIVERS Top 2x 6-32 thread, 0.5'' countersunk head Phillips screw Top Mounting bracket Mounting bracket 3x M4 x 12mm length pan head Phillips screw for deep canopy WITH REQUIRED HARDWARE 1x 4" octagonal/round junction box (by others) 2x Cable restraint 1x Cylinder tool LACYM OR LACYL PENDANT STEM MOUNT OR FLAT CANOPY NOTICE TO SIMPLIFY INSTALLATION, KEEP THE MOUNTING MECHANISM AND FIXTURE'S PARTS IN A SECURE PLACE. DEEP CANOPY Bottom Bottom Pre-wired stem Pre-wired stem WIRING DIAGRAM AT JUNCTION BOX Wiring Color Code LUMENTALK (LT) ON/OFF CONTROL (NO) PHASE DIMMING (PH, PPH) To fixture To fixture Power input or from previous fixture To next fixture Live Ground Power input (control over power line via Lumentalk system) or from previous fixture 0-10V DIMMING (DA1, DA2, DA3, PDA1, PDA2) DALI DIMMING (DALI1, DALI2) LUTRON® ECOSYSTEM® ENABLED DIMMING (ES) Lumenterminator (use at the end of each run only) Data To next fixture Live Ground Neutral Wire-nuts (by others) From : Third party dimmer, Third party DALI controller or Lutron® EcoSystem® controller Neutral Wire-nuts (by others) DMX/RDM STAR LAYOUT OR DAISY CHAIN LAYOUT END OF RUN Data + Power input or from previous fixture From CBX or previous fixture Octagonal/round junction box (by others) DMX/RDM DAISY CHAIN LAYOUT (FIRST OR MIDDLE OF RUN) To fixture To fixture Data Data + Neutral Ground Live Wire-nuts (by others) 2017.08.07 SA - R1 To next/from previous fixture Live Ground Neutral Wire-nuts (by others) Octagonal/round junction box (by others) DMX terminator is required at the end of each run to maintain data integrity. (2x) lumenterminators included per CBX-DS (6x) lumenterminators included per CBX-ST Combined Power & Data Cable Specification Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant. p.1/4 Data + Data - From CBX or previous fixture DMX/Data Cable Specification DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance. ™ *347V available for NO and DA3 control options for LACYM and NO, DA3 and DMX/RDM control options for LACYL only. Live Octagonal/round junction box (by others) Wire-nuts (by others) To fixture To next fixture Use Ground Live 120-347V* Neutral 0-10V / Data + 0-10V / Data - Ground Neutral Octagonal/round junction box (by others) Octagonal/round junction box (by others Color Green Black White Red or purple Orange or grey NOTICE MULTIPLE FIXTURES SHOULD NOT BE LANDED UNDER ONE TERMINATION POINT NOTICE RECORD THE LOCATION OF EACH FIXTURE BY SERIAL NUMBER TO PREPARE FOR THE COMMISSIONING PROCESS (DMX/RDM) Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. 1220 Marie-Victorin Boulevard, Longueuil (Quebec) Canada J4G 2H9 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenalpha.com Copyright © Lumenpulse Group Inc. 2017 Confidential and proprietary Lumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See http://www.lumenalpha.com/support/downloads for current data and instructions. cylinder INSTALLATION INSTRUCTIONS PENDANT STEM MOUNT DEEP AND FLAT CANOPY LACYM - MEDIUM LACYL - LARGE drawing number 133065 This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. ! REMOVE MOUNTING PLATE AND INSTALL STEM 1 2 « click » 3 Bottom UNLOCK MOUNTING PLATE USING PROVIDED TOOL AND TWIST FIXTURE BODY COUNTERCLOCKWISE TO DETACH FROM TOP RING LOCK TOP RING INTO STEM USING PROVIDED NUT SCREW CABLE RESTRAINT ONTO CABLE KEEP ENOUGH CABLE LENGTH TO MAKE CONNECTIONS FLAT CANOPY INSTALLATION INSTALL STEM ON THE CEILING 1 2 3 4 Top Top Bottom Bottom SLIDE CANOPY TOP ONTO STEM SCREW CABLE RESTRAINT INTO CABLE LOCK CROSS BAR INTO STEM USING PROVIDED NUT. KEEP ENOUGH CABLE LENGTH TO MAKE CONNECTIONS 2X 6-32 ATTACH CROSS BAR TO JUNCTION BOX USING PROVIDED SCREWS MAKE ELECTRICAL CONNECTIONS IN JUNCTION BOX, SEE WIRING DETAILS ON PAGE 1. AND SLIDE CANOPY TO CEILING DEEP CANOPY INSTALLATION INSTALL STEM ON THE CEILING 2 1 3 5 4 Top Top « click » Bottom Bottom 3X M4 x 12mm 2X 6-32 REMOVE AND SCREW MOUNTING PLATE ON JUNCTION BOX ™ p.2/4 2017.08.07 SA - R1 SLIDE CANOPY CAP INTO STEM AND LEAVE IT HANGING SLIDE MOUNTING BRACKET INTO STEM. LOCK MOUNTING BRACKET TO STEM AND SCREW CABLE RESTRAINT INTO CABLE SECURE MOUNTING BRACKET IN PLACE USING PROVIDED SCREWS. SCREWS TO REMAIN CAPTIVE TO ALLOW BRACKET TO SLIDE IN TIGHTEN SCREWS ONCE BRACKET IS IN PLACE MAKE ELECTRICAL CONNECTIONS IN JUNCTION BOX, SEE WIRING DETAILS ON PAGE 1. AND SLIDE CANOPY TO CEILING Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. 1220 Marie-Victorin Boulevard, Longueuil (Quebec) Canada J4G 2H9 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenalpha.com Copyright © Lumenpulse Group Inc. 2017 Confidential and proprietary Lumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See http://www.lumenalpha.com/support/downloads for current data and instructions. cylinder INSTALLATION INSTRUCTIONS drawing number 133065 This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. ! PENDANT STEM MOUNT DEEP AND FLAT CANOPY LACYM - MEDIUM LACYL - LARGE INSTALL FIXTURE ON STEM 1 FLAT OR DEEP CANOPY 2 Bottom CLIP SAFETY CABLE TO HOLD FIXTURE IN PLACE AND USE WAGOS INSIDE THE FIXTURE TO MAKE ELECTRICAL CONNECTIONS FLAT CANOPY OR ™ p.3/4 2017.08.07 SA - R1 TWIST FIXTURE BODY CLOCKWISE TO LOCK ON MOUNTING PLATE DEEP CANOPY Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. 1220 Marie-Victorin Boulevard, Longueuil (Quebec) Canada J4G 2H9 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenalpha.com Copyright © Lumenpulse Group Inc. 2017 Confidential and proprietary Lumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See http://www.lumenalpha.com/support/downloads for current data and instructions. cylinder INSTALLATION INSTRUCTIONS PENDANT STEM MOUNT DEEP AND FLAT CANOPY LACYM - MEDIUM LACYL - LARGE drawing number 133065 This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. ! ACCESSORY INSTALLATION LINEAR SPREAD LENS ACCESSORY LSN - LINEAR SPREAD LENS NARROW (1° X 40°) LSW - LINEAR SPREAD LENS WIDE (1° X 60°) 60° 40° 1° Notch Notches 1° Notch Notches 40° 1° BOTTOM VIEW BOTTOM VIEW HORIZONTAL BEAM DISTRIBUTION BOTTOM VIEW VERTICAL BEAM DISTRIBUTION NOTICE 1° 60° ALIGN SPREAD LENS NOTCHES ACCORDING TO DESIRED BEAM DISTRIBUTION BOTTOM VIEW HORIZONTAL BEAM DISTRIBUTION VERTICAL BEAM DISTRIBUTION CLEAR (CL), SOFTENING (SL) AND SPREAD LENSES (LSN, LSW), HONEYCOMB LOUVER (HL) 1 2 3 4 Safety cable Clear glass lens (CL) Softening glass lens (SL) Linear Spread Lens Narrow (LSN) Linear Spread Lens Wide (LSW) Honeycomb louver (HL) PUSH IN AND TWIST THE DECORATIVE BEZEL A QUARTER TURN COUNTERCLOCKWISE REMOVE THE DECORATIVE BEZEL FROM THE FIXTURE HOUSING. THE BEZEL CAN HANG FROM THE PROVIDED SAFETY CABLE CHANGE ACCESSORY NOTICE TEXTURED/FROSTED SIDE SHOULD FACE THE LED ASSEMBLY ALIGN THE DECORATIVE BEZEL INTO THE FRONT RING. PUSH IN AND TWIST DECORATIVE BEZEL A QUARTER TURN CLOCKWISE TO PUT IT BACK IN PLACE SNOOT (SN) AND HALF SNOOT (HS) REQUIRED TOOLS: NEEDLE NOSE PLIERS HALF SNOOT (HSN) #1 PHILLIPS SCREWDRIVER SNOOT (SN) 1 2 3 4 Safety cable PUSH IN AND TWIST THE DECORATIVE BEZEL A QUARTER TURN COUNTERCLOCKWISE REMOVE THE DECORATIVE BEZEL FROM THE FIXTURE HOUSING. THE BEZEL CAN HANG FROM THE PROVIDED SAFETY CABLE. REMOVE ANY INSTALLED ACCESSORY 6 5 FOLD DOWN 4X TABS (PLIERS REQUIRED). ENSURE TABS ARE FLAT TO ALLOW ACCESSORIES TO SIT FLUSH ON RING ™ p.4/4 2017.08.07 SA - R1 REPLACE REMAINING ACCESSORY UNSCREW AND REMOVE THE SAFETY CABLE FROM THE DECORATIVE BEZEL 7 PLACE FRONT RING ON TOP OF SNOOT OR HALF SNOOT TO SECURE IN PLACE 8 REPLACE THE SAFETY CABLE AND SCREW INTO DECORATIVE BEZEL ALIGN THE DECORATIVE BEZEL INTO THE FRONT RING. PUSH IN AND TWIST DECORATIVE BEZEL A QUARTER TURN CLOCKWISE TO PUT IT BACK IN PLACE Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. 1220 Marie-Victorin Boulevard, Longueuil (Quebec) Canada J4G 2H9 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenalpha.com Copyright © Lumenpulse Group Inc. 2017 Confidential and proprietary Lumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See http://www.lumenalpha.com/support/downloads for current data and instructions.