INSTALLATION INSTRUCTIONS
PENDANT STEM MOUNT DEEP AND FLAT CANOPY LACYM - MEDIUM LACYL - LARGE
drawing number 133065
This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury.
! WARNING
!
!
Do not exceed fixture specified voltage.
WARNING
!
WARNING
!
Do not install if fixture, parts or connectors are damaged.
Disconnect power before installing or servicing to avoid electrical shock.
!
WARNING
Do not attempt to clean reflector with cleaning agent or paper towels or cloth. This will permanently damage the reflector.
CAUTION
Unauthorized field repairs or modifications will void warranty. Tampering with power supply, factory wiring or hardware will void warranty.
!
!
WARNING
Separation of field installed power limited circuit (dimming/control) wiring from the branch circuit wiring in the outlet box are to be made in accordance with local and/or national electrical installation codes. !
WARNING
WARNING
Products are rated for an ambient of 30 °C [86 °F].
CAUTION
This luminaire is not suitable for fire-rated installations.
CAUTION
CAUTION
Interior use only. The product must only be installed in the applicable zone according to national regulations. Any damaged or cracked protective shield must be replaced to ensure IP rating is maintained.
CAUTION
Product must be installed with provided Lumenalpha power supplies and housings only. Use of other manufacturers' components will void warranty.
Do not install upside down or horizontally.
AS DELIVERED
Always wear clean latex or cotton gloves when handling the reflector and mounting mechanism. Marks left on the reflector will reduce light output and cause damage not covered by the manufacturer’s warranty.
LUMINAIRE MOUNTING KIT: REQUIRED TOOL: PHILLIPS SCREWDRIVERS
Top
2x 6-32 thread, 0.5'' countersunk head Phillips screw
Top
Mounting bracket
Mounting bracket
3x M4 x 12mm length pan head Phillips screw for deep canopy
WITH
REQUIRED HARDWARE 1x 4" octagonal/round junction box (by others)
2x Cable restraint
1x Cylinder tool
LACYM OR LACYL PENDANT STEM MOUNT
OR
FLAT CANOPY
NOTICE TO SIMPLIFY INSTALLATION, KEEP THE MOUNTING MECHANISM AND FIXTURE'S PARTS IN A SECURE PLACE.
DEEP CANOPY
Bottom
Bottom
Pre-wired stem
Pre-wired stem
WIRING DIAGRAM AT JUNCTION BOX Wiring Color Code
LUMENTALK (LT)
ON/OFF CONTROL (NO) PHASE DIMMING (PH, PPH) To fixture
To fixture
Power input or from previous fixture
To next fixture Live Ground
Power input (control over power line via Lumentalk system) or from previous fixture
0-10V DIMMING (DA1, DA2, DA3, PDA1, PDA2) DALI DIMMING (DALI1, DALI2) LUTRON® ECOSYSTEM® ENABLED DIMMING (ES)
Lumenterminator (use at the end of each run only)
Data To next fixture Live Ground Neutral Wire-nuts (by others) From : Third party dimmer, Third party DALI controller or Lutron® EcoSystem® controller
Neutral Wire-nuts (by others)
DMX/RDM STAR LAYOUT OR DAISY CHAIN LAYOUT END OF RUN
Data +
Power input or from previous fixture
From CBX or previous fixture
Octagonal/round junction box (by others)
DMX/RDM DAISY CHAIN LAYOUT (FIRST OR MIDDLE OF RUN)
To fixture
To fixture Data Data + Neutral Ground Live
Wire-nuts (by others)
2017.08.07 SA - R1
To next/from previous fixture Live Ground Neutral Wire-nuts (by others)
Octagonal/round junction box (by others)
DMX terminator is required at the end of each run to maintain data integrity. (2x) lumenterminators included per CBX-DS (6x) lumenterminators included per CBX-ST
Combined Power & Data Cable Specification Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant.
p.1/4
Data + Data -
From CBX or previous fixture
DMX/Data Cable Specification DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance.
™
*347V available for NO and DA3 control options for LACYM and NO, DA3 and DMX/RDM control options for LACYL only.
Live
Octagonal/round junction box (by others)
Wire-nuts (by others)
To fixture
To next fixture
Use Ground Live 120-347V* Neutral 0-10V / Data + 0-10V / Data -
Ground
Neutral
Octagonal/round junction box (by others)
Octagonal/round junction box (by others
Color Green Black White Red or purple Orange or grey
NOTICE MULTIPLE FIXTURES SHOULD NOT BE LANDED UNDER ONE TERMINATION POINT
NOTICE RECORD THE LOCATION OF EACH FIXTURE BY SERIAL NUMBER TO PREPARE FOR THE COMMISSIONING PROCESS (DMX/RDM)
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. 1220 Marie-Victorin Boulevard, Longueuil (Quebec) Canada J4G 2H9 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenalpha.com Copyright © Lumenpulse Group Inc. 2017 Confidential and proprietary Lumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See http://www.lumenalpha.com/support/downloads for current data and instructions.
cylinder
INSTALLATION INSTRUCTIONS
PENDANT STEM MOUNT DEEP AND FLAT CANOPY LACYM - MEDIUM LACYL - LARGE
drawing number 133065
This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury.
!
REMOVE MOUNTING PLATE AND INSTALL STEM
1
2
« click »
3
Bottom
UNLOCK MOUNTING PLATE USING PROVIDED TOOL AND TWIST FIXTURE BODY COUNTERCLOCKWISE TO DETACH FROM TOP RING
LOCK TOP RING INTO STEM USING PROVIDED NUT
SCREW CABLE RESTRAINT ONTO CABLE KEEP ENOUGH CABLE LENGTH TO MAKE CONNECTIONS
FLAT CANOPY INSTALLATION INSTALL STEM ON THE CEILING
1
2
3
4
Top
Top
Bottom Bottom
SLIDE CANOPY TOP ONTO STEM
SCREW CABLE RESTRAINT INTO CABLE LOCK CROSS BAR INTO STEM USING PROVIDED NUT. KEEP ENOUGH CABLE LENGTH TO MAKE CONNECTIONS
2X 6-32 ATTACH CROSS BAR TO JUNCTION BOX USING PROVIDED SCREWS
MAKE ELECTRICAL CONNECTIONS IN JUNCTION BOX, SEE WIRING DETAILS ON PAGE 1. AND SLIDE CANOPY TO CEILING
DEEP CANOPY INSTALLATION INSTALL STEM ON THE CEILING
2
1
3
5
4
Top
Top
« click »
Bottom
Bottom
3X M4 x 12mm
2X 6-32 REMOVE AND SCREW MOUNTING PLATE ON JUNCTION BOX
™
p.2/4
2017.08.07 SA - R1
SLIDE CANOPY CAP INTO STEM AND LEAVE IT HANGING
SLIDE MOUNTING BRACKET INTO STEM. LOCK MOUNTING BRACKET TO STEM AND SCREW CABLE RESTRAINT INTO CABLE
SECURE MOUNTING BRACKET IN PLACE USING PROVIDED SCREWS. SCREWS TO REMAIN CAPTIVE TO ALLOW BRACKET TO SLIDE IN TIGHTEN SCREWS ONCE BRACKET IS IN PLACE
MAKE ELECTRICAL CONNECTIONS IN JUNCTION BOX, SEE WIRING DETAILS ON PAGE 1. AND SLIDE CANOPY TO CEILING
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. 1220 Marie-Victorin Boulevard, Longueuil (Quebec) Canada J4G 2H9 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenalpha.com Copyright © Lumenpulse Group Inc. 2017 Confidential and proprietary Lumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See http://www.lumenalpha.com/support/downloads for current data and instructions.
cylinder
INSTALLATION INSTRUCTIONS drawing number 133065
This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury.
!
PENDANT STEM MOUNT DEEP AND FLAT CANOPY LACYM - MEDIUM LACYL - LARGE
INSTALL FIXTURE ON STEM
1
FLAT OR DEEP CANOPY
2
Bottom
CLIP SAFETY CABLE TO HOLD FIXTURE IN PLACE AND USE WAGOS INSIDE THE FIXTURE TO MAKE ELECTRICAL CONNECTIONS
FLAT CANOPY
OR
™
p.3/4
2017.08.07 SA - R1
TWIST FIXTURE BODY CLOCKWISE TO LOCK ON MOUNTING PLATE
DEEP CANOPY
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. 1220 Marie-Victorin Boulevard, Longueuil (Quebec) Canada J4G 2H9 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenalpha.com Copyright © Lumenpulse Group Inc. 2017 Confidential and proprietary Lumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See http://www.lumenalpha.com/support/downloads for current data and instructions.
cylinder
INSTALLATION INSTRUCTIONS
PENDANT STEM MOUNT DEEP AND FLAT CANOPY LACYM - MEDIUM LACYL - LARGE
drawing number 133065
This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury.
!
ACCESSORY INSTALLATION LINEAR SPREAD LENS ACCESSORY LSN - LINEAR SPREAD LENS NARROW (1° X 40°)
LSW - LINEAR SPREAD LENS WIDE (1° X 60°) 60° 40°
1°
Notch
Notches
1°
Notch
Notches
40°
1°
BOTTOM VIEW
BOTTOM VIEW
HORIZONTAL BEAM DISTRIBUTION
BOTTOM VIEW
VERTICAL BEAM DISTRIBUTION
NOTICE
1°
60°
ALIGN SPREAD LENS NOTCHES ACCORDING TO DESIRED BEAM DISTRIBUTION
BOTTOM VIEW
HORIZONTAL BEAM DISTRIBUTION
VERTICAL BEAM DISTRIBUTION
CLEAR (CL), SOFTENING (SL) AND SPREAD LENSES (LSN, LSW), HONEYCOMB LOUVER (HL) 1
2
3
4
Safety cable Clear glass lens (CL) Softening glass lens (SL) Linear Spread Lens Narrow (LSN) Linear Spread Lens Wide (LSW) Honeycomb louver (HL)
PUSH IN AND TWIST THE DECORATIVE BEZEL A QUARTER TURN COUNTERCLOCKWISE
REMOVE THE DECORATIVE BEZEL FROM THE FIXTURE HOUSING. THE BEZEL CAN HANG FROM THE PROVIDED SAFETY CABLE
CHANGE ACCESSORY NOTICE TEXTURED/FROSTED SIDE SHOULD FACE THE LED ASSEMBLY
ALIGN THE DECORATIVE BEZEL INTO THE FRONT RING. PUSH IN AND TWIST DECORATIVE BEZEL A QUARTER TURN CLOCKWISE TO PUT IT BACK IN PLACE
SNOOT (SN) AND HALF SNOOT (HS) REQUIRED TOOLS: NEEDLE NOSE PLIERS
HALF SNOOT (HSN)
#1 PHILLIPS SCREWDRIVER
SNOOT (SN)
1
2
3
4
Safety cable
PUSH IN AND TWIST THE DECORATIVE BEZEL A QUARTER TURN COUNTERCLOCKWISE
REMOVE THE DECORATIVE BEZEL FROM THE FIXTURE HOUSING. THE BEZEL CAN HANG FROM THE PROVIDED SAFETY CABLE. REMOVE ANY INSTALLED ACCESSORY
6
5
FOLD DOWN 4X TABS (PLIERS REQUIRED). ENSURE TABS ARE FLAT TO ALLOW ACCESSORIES TO SIT FLUSH ON RING
™
p.4/4
2017.08.07 SA - R1
REPLACE REMAINING ACCESSORY
UNSCREW AND REMOVE THE SAFETY CABLE FROM THE DECORATIVE BEZEL
7
PLACE FRONT RING ON TOP OF SNOOT OR HALF SNOOT TO SECURE IN PLACE
8
REPLACE THE SAFETY CABLE AND SCREW INTO DECORATIVE BEZEL
ALIGN THE DECORATIVE BEZEL INTO THE FRONT RING. PUSH IN AND TWIST DECORATIVE BEZEL A QUARTER TURN CLOCKWISE TO PUT IT BACK IN PLACE
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system. 1220 Marie-Victorin Boulevard, Longueuil (Quebec) Canada J4G 2H9 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenalpha.com Copyright © Lumenpulse Group Inc. 2017 Confidential and proprietary Lumenpulse Group Inc. reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See http://www.lumenalpha.com/support/downloads for current data and instructions.