Transcript
INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200
2
1. Roll down window to avoid locking keys in vehicle during installation 2. Avoid mounting components or routing wires near hot surfaces 3. Avoid mounting components or routing wires near moving parts 4. Tape or loom wires under hood for protection and appearance 5. Use grommets when routing wires through metal surfaces 6. Use a voltmeter for testing and verifying circuits
Installation Precautions:
PROFESSIONAL INSTALLATION STONGLY RECOMMENDED
For more information about FUSION Electronics visit our website at www.fusionelectronics.com or email
[email protected]
car audio. Make some noise.
Leave the old behind and push the limits of what can be achieved in
peripherals that redefine what can be done in car audio.
distinctively different products; subwoofers, amplifiers, speakers and
outstanding performance and quality. Our development team create
innovation. Where new levels of entertainment are delivered with
technology is creatively combined with the latest in product
arrived in a world where the old limits are left behind. Where
Now you are ready. Step out of the shadows and announce you’ve
making some noise.
our product, to our demo cars, to our events, FUSION is about
believed the way to make things happen is by getting noticed. From
There’s no point doing something if no one notices. We’ve always
FUSION CULTURE
AFFIX RECEIPT HERE
MODEL NUMBER _______________________________ DATE OF PURCHASE________________
RECORD YOUR PRODUCT DETAILS HERE:
• SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 15
• CENTRAL LOCKING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 11
• WIRING DIAGRAMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 9
• ADJUSTING THE SENSITIVITY LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . pg 8
• ALARM FEATURES PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . pg 5
• PROGRAMMING REMOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 4
TABLE OF CONTENTS
3
4
Note: This mode will only retain the last 4 remote transmitters programmed. If the remote memory is exceeded, the security system will start deleting remote’s from memory in chronological order.
Exit Programming: Turn ignition to ‘OFF’ position, or wait for 15 seconds. Three long chirps and three indicator light flashes will confirm exit.
4. If you have additional remotes (up to 4 in total) that need to be programmed, repeat step 3 for each remote.
3. Press and hold any button of the remote until the siren responds with a confirming chirp, this indicates the remote has been stored into memory.
2. Push the valet switch 3 times, and hold on the 3rd push until a long chirp is heard from the siren, and then release the valet switch. You are now in the remote programming mode.
1. Turn the ignition switch ‘OFF/ON’ 3 times (within 15 seconds) and leave in the ON position.
PROGRAMMING REMOTES
Automatic Rearm Off 45 second Delay Door Ajar warning
Automatic Rearm On Instant Door Ajar Warning
Exit Programming: Turn ignition to ‘ON’ position, or wait 15 seconds. Three long chirps will confirm exit.
3
+
Chirps off
Chirps on 1 2
Two Chirps / LED two flashes
One Chirp / LED one flash Factory Default Setting
Press remote button
Note: The factory default setting is always [1] LED flash, [1] chirp.
C; Press and release the remote buttons + corresponding to the feature ‘3’ to be changed. The siren will chirp and the LED will indicate the new setting
B; Press and release the remote button corresponding to the feature ‘2’ to be changed. The siren will chirp and the LED will indicate the new setting
3. A; Press and release the remote button corresponding to the feature ‘1’ to be changed. The siren will chirp and the LED will indicate the new setting
2. Push the valet switch twice, and hold on the 2nd push until one short chirp, followed by one long chirp is heard then release the valet switch. You are now in the alarm feature ‘I’ programming mode.
1. Turn the ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds) and leave in the OFF position on the 3rd time.
ALARM FEATURE “I” PROGRAMMING:
ALARM FEATURES PROGRAMMING:
5
6
corresponding to the
+
corresponding to
Passive arming without passive door locking
Without ignition controlled door locks & unlocks
Active arming
Ignition controlled door locks & unlocks
Passive arming with passive door locking
double pulse unlock
Three Chirps / LED three flashes
Exit Programming: Turn ignition to ‘ON’ position, or wait for 15 seconds. Three long chirps will confirm exit.
3
+
3.0 - second door lock pulse
0.9 - second door lock pulses
1
2
Two Chirps / LED two flashes
One Chirp / LED one pulse Factory Default Setting
Press remote button
Note: The factory default setting is always [1] LED flash, [1] chirp.
The siren will chirp and the LED will indicate the new setting.
C; Press and release the remote buttons the feature ‘3’ to be changed.
The siren will chirp and the LED will indicate the new setting.
B; Press and release the remote button feature ‘2’ to be changed.
The siren will chirp and the LED will indicate the new setting.
+
Grey wire = two step door unlock output Anti car jacking on
Anti car jacking off
Shock sensor program mode
Two Chirps / LED two flashes
Grey wire = trunk/ boot (Channel 3) output
One Chirp / LED one pulse Factory Default Setting
Exit Programming: Turn Ignition to ‘ON’ position, or waitw for 15 seconds. Three long chirps will confirm exit.
3
2
1
Press remote button
Note: The factory default setting is always [1] LED flash, [1] chirp.
C; Press and release the remote buttons + corresponding to the feature ‘3’ to be changed. The siren will chirp and the LED will indicate the new setting.
B; Press and release the remote button corresponding to the feature ‘2’ to be changed. The siren will chirp and the LED will indicate the new setting.
3. A; Press and release the remote button corresponding to the feature ‘1’ to be changed. The siren will chirp and the LED will indicate the new setting.
2. Push the valet switch 6 times and hold on the 6th push until three short chirps and one long chirp is heard, and then release the valet switch. You are now in the Alarm feature ‘III’ programming mode.
2. Push the valet switch 4 times and hold on the 4th push until two short chirps and one long chirp is heard, and then release the valet switch. You are now in the alarm feature ‘II’ programming mode. corresponding to the
1. Turn the ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds), and leave in the OFF position.
1. Turn the Ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds), and leave in the OFF position.
3. A; Press and release the remote button feature ‘1’ to be changed.
ALARM FEATURE “III” PROGRAMMING:
ALARM FEATURE “II” PROGRAMMING:
7
8
Note: If 20 seconds of inactivity expire, or the ignition is turned on during the above steps, the unit will exit the programing mode and return to the disarmed mode. Three long chirps will confirm exit.
9. When you are satisfied with the setting, press and buttons simultaneously. One long siren chirp indicates the unit has confirmed the setting.
5. Pressing button on the remote once will increase sensitivity level by one, each time an increase is made the siren will respond with one chirp, while 2 chirp’s indicates the maximum sensitivity setting. 6. Hit the bumper or strong metal part of the vehicle to test the threshold level of the sensor. a). Activate the warn-away (first stage of the shock sensor), the siren will emit a short chirp. b). Activate the full alarm (second stage of the shock sensor), the siren will emit a long chirp. 7. When you are satisfied with the second stage of the shock sensor settings, press and hold and buttons simultaneously for 2 seconds. Two long siren chirps will indicate the unit is ready to accept adjustments of the first stage of the shock sensor (warn-away). 8. Follow the steps 4, 5 and 6 to adjust the warn-away sensitivity.
3. Press and hold button for 2 seconds. One long siren chirp will indicate the unit is ready to accept adjustments of the second stage of the shock sensor (full alarm). 4. Pressing the button on the remote once will decrease the sensitivity level by one, each time a decrease is made the siren will respond with one chirp, while 2 chirp’s indicates the minimum sensitivity setting.
1. Turn the ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds) and leave in the OFF position. 2. Push the valet switch 6 times and hold on the 6th push until three short chirps and one long chirp is heard, and then release the valet switch. You are now in the alarm feature ‘Shock Sensor’ programming mode.
ADJUSTING THE SENSITIVITY LEVEL OF THE SHOCK SENSOR
2 Pin Blue
6 Pin White
6 Pin White
2 Pin White
6 Pin White
6. Red Wire: +12V To Constant Battery Source
5. Brown Wire: Positive output To Siren
4. Black Wire: Ground to Vehicle FRAME
3. White Wire: Turn Indicator Relay Output
2. Red / White Wire: Turn Indicator Relay Power input
1. White Wire: Turn Indicator Relay Output
A: MAIN 6 PIN WIRE HARNESS:
Valet Switch
Black Antenna Wire
WIRING DIAGRAM
LED Indicator
Turn Indicator
15A Fuse
Main 6 Pin Wire harness
Wire harness
6 Pin Door Lock/Unlock
6 Pin Mini Connector
9
Yellow wire
10
D o o r U n lo c k C o n tro l W ire
H 7 /2W h ite /G re e n w ire fo r d o o r lo c k c o n tro l (-) in p u t
H 7 /3W h ite /B la c k w ire fo r d o o r u n lo c k c o n tro l (-) in p u t
+12V
Blue / yellow
Green / yellow
Door Lock Door unlock
Blue / white
M aster Locking Switch
NEGATIVE TRIGGER DOOR LOCK SYSTEM
(Factory Door Locking System)
B: CENTRAL LOCKING DIAGRAMS
H7
B lu e / y e llo w G re e n / y e llo w
B lu e / w h ite
G re e n / w h ite
G re e n / re d
B lu e / re d
Green/White W ire: (30) - Door Lock Relay
Green/Yellow W ire: (87) - Door Lock Relay
+12V
D oor Lock C o n tro l W ire
INSTALLING 4 DOOR LOCK MOTORS (WITH 5-WIRE LOCK MOTOR)
Green/ yellow
Blue/ yellow
Green / white
Orange wire
White wire
To start solenoid
12V
Green/ red
Blue/ red
Blue/ white
Green/ white
INSTALLING DOOR LOCK MOTORS (2 WIRE)
(After market Door Motors)
A: CENTRAL LOCKING DIAGRAMS
Green/Red W ire: (87a) - Door Lock Relay
Blue/Yellow W ire: (87) - Door Unlock Relay
Blue/White W ire: (30) - Door Unlock Relay
Blue/Red W ire: (87a) - Door Unlock Relay
(See central locking diagrams)
30
Cut
85 87a 86
Red wire
From ignition switch
C: 6PIN DOOR LOCK/UNLOCK WIRE HARNESS:
6. Gray Wire: (-) 200mA Programmable Output Channel 3 / 2 Step Door Unlock.
5. Orange Wire: 200mA Grounded when armed
4. Yellow Wire: To Ignition Switched + 12V
3. Green Wire: Negative Door Pin Switch Input
2. Blue Wire: Instant Trigger Ground Input
1. Violet Wire: Positive Door Pin Switch Input
12V
B: 6 PIN MINI CONNECTOR WIRE HARNESS:
11
Door unlock
Splic
To Slave Door Lock switches
+ 12V
Cut the Existing Unlock Wire Splic
X
X
To Door Lock
Cut the Existing Lock Wire
+12V
M aster Locking Switch
12
Blue/ yellow
Green/ yellow
Blue/ white
Green/ red
Blue/ red
Green/ white
+12V
Cut X
Compressor
Door Switch
VACUUM OPERATED DOOR LOCKING SYSTEM
Blue/ yellow
Green/ yellow
Blue/ white
Blue/ red
Green/ white
Green/ red
Master Door Lock Switch
ALTERNATING DOOR LOCKS
Blue / yellow
Green / yellow
Door Lock
Blue / white
Green / white
POSITIVE TRIGGER DOOR LOCK SYSTEM
30
Blue / Yellow
Blue / White
Unlock
X
+ 12V
Unlock
Cut the Unlock Wire
85
+12V
x
+12V
To All Other Door Lock Motors
Lock
OEM Slave Door Lock Switch
Cut the Existing Lock Wire
Lock
H4 6-Pin Door Lock Wire Harness
OEM Door Lock Motor
Blue / Yellow
Green / Yellow
Green / White
Blue / White
Blue / Red
H7/9 Brown Wire
X
OEM Door Lock Relay
Cut Existing Unlock Wire
+12V
Existing Unlock Wire
Unlock
To All Other Door Lock Motor
Existing Lock Wire
Lock
OEM Door Master Lock Switch
2 STEP DOOR UNLOCK WIRE CONNECTIONS FOR GROUND SWITCHED DOOR LOCKS
x
OEM Door Master Lock
Cut Existing Unlock Wire
Green / Yellow
Green / White
Blue / Red
87
87A
86
Green / Red
OEM Driver's Door Lock Motor
H4 6-Pin Door Lock Wire Harness
H7/9 Brown Wire
+ 12V
2 STEP DOOR UNLOCK WIRE CONNECTIONS FOR 5 WIRE ALTERNATING DOOR LOCKS
13
14
H4 6-Pin Door Lock Wire Harness
86
Green / Yellow
OEM Driver's Door Lock Motor
Blue / Yellow
87
X
Existing Pos. Unlock Wire
OEM Door Lock Relay
+ 12V
Lock
To All Other Door Lock Motors
Existing Pos. Lock Wire
OEM Door Master Lock
Unlock
+ 12V
85
Cut Existing Unlock
87A 30
Green / White
Blue / White
Blue / Red
H7/9 Brown Wire
+12V
2 STEP DOOR UNLOCK WIRE CONNECTIONS FOR POSITIVE SWITCHED DOOR LOCKS
15 Amp 10 Amp 10 Amp 15 mA
10VDC – 16VDC -40 °C – +80 °C (-40 °F – +176 °F ) 433.92 M Hz
Z105
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
FCC: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions.
THE FUSION CE-SS200 SECURITY SYSTEM COMPLIES WITH:
Note: Remote control range is dependant on weather conditions and alarm installation.
Indicator light flash output: Door Lock: Door Unlock: Security system (disarmed):
POWER CONSUMPTION:
Power supply: Operating temperature: TX Frequency:
SPECIFICATIONS:
15