Preview only show first 10 pages with watermark. For full document please download

Installation Manual

   EMBED


Share

Transcript

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200 2 1. Roll down window to avoid locking keys in vehicle during installation 2. Avoid mounting components or routing wires near hot surfaces 3. Avoid mounting components or routing wires near moving parts 4. Tape or loom wires under hood for protection and appearance 5. Use grommets when routing wires through metal surfaces 6. Use a voltmeter for testing and verifying circuits Installation Precautions: PROFESSIONAL INSTALLATION STONGLY RECOMMENDED For more information about FUSION Electronics visit our website at www.fusionelectronics.com or email [email protected] car audio. Make some noise. Leave the old behind and push the limits of what can be achieved in peripherals that redefine what can be done in car audio. distinctively different products; subwoofers, amplifiers, speakers and outstanding performance and quality. Our development team create innovation. Where new levels of entertainment are delivered with technology is creatively combined with the latest in product arrived in a world where the old limits are left behind. Where Now you are ready. Step out of the shadows and announce you’ve making some noise. our product, to our demo cars, to our events, FUSION is about believed the way to make things happen is by getting noticed. From There’s no point doing something if no one notices. We’ve always FUSION CULTURE AFFIX RECEIPT HERE MODEL NUMBER _______________________________ DATE OF PURCHASE________________ RECORD YOUR PRODUCT DETAILS HERE: • SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 15 • CENTRAL LOCKING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 11 • WIRING DIAGRAMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 9 • ADJUSTING THE SENSITIVITY LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . pg 8 • ALARM FEATURES PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . pg 5 • PROGRAMMING REMOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 4 TABLE OF CONTENTS 3 4 Note: This mode will only retain the last 4 remote transmitters programmed. If the remote memory is exceeded, the security system will start deleting remote’s from memory in chronological order. Exit Programming: Turn ignition to ‘OFF’ position, or wait for 15 seconds. Three long chirps and three indicator light flashes will confirm exit. 4. If you have additional remotes (up to 4 in total) that need to be programmed, repeat step 3 for each remote. 3. Press and hold any button of the remote until the siren responds with a confirming chirp, this indicates the remote has been stored into memory. 2. Push the valet switch 3 times, and hold on the 3rd push until a long chirp is heard from the siren, and then release the valet switch. You are now in the remote programming mode. 1. Turn the ignition switch ‘OFF/ON’ 3 times (within 15 seconds) and leave in the ON position. PROGRAMMING REMOTES Automatic Rearm Off 45 second Delay Door Ajar warning Automatic Rearm On Instant Door Ajar Warning Exit Programming: Turn ignition to ‘ON’ position, or wait 15 seconds. Three long chirps will confirm exit. 3 + Chirps off Chirps on 1 2 Two Chirps / LED two flashes One Chirp / LED one flash Factory Default Setting Press remote button Note: The factory default setting is always [1] LED flash, [1] chirp. C; Press and release the remote buttons + corresponding to the feature ‘3’ to be changed. The siren will chirp and the LED will indicate the new setting B; Press and release the remote button corresponding to the feature ‘2’ to be changed. The siren will chirp and the LED will indicate the new setting 3. A; Press and release the remote button corresponding to the feature ‘1’ to be changed. The siren will chirp and the LED will indicate the new setting 2. Push the valet switch twice, and hold on the 2nd push until one short chirp, followed by one long chirp is heard then release the valet switch. You are now in the alarm feature ‘I’ programming mode. 1. Turn the ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds) and leave in the OFF position on the 3rd time. ALARM FEATURE “I” PROGRAMMING: ALARM FEATURES PROGRAMMING: 5 6 corresponding to the + corresponding to Passive arming without passive door locking Without ignition controlled door locks & unlocks Active arming Ignition controlled door locks & unlocks Passive arming with passive door locking double pulse unlock Three Chirps / LED three flashes Exit Programming: Turn ignition to ‘ON’ position, or wait for 15 seconds. Three long chirps will confirm exit. 3 + 3.0 - second door lock pulse 0.9 - second door lock pulses 1 2 Two Chirps / LED two flashes One Chirp / LED one pulse Factory Default Setting Press remote button Note: The factory default setting is always [1] LED flash, [1] chirp. The siren will chirp and the LED will indicate the new setting. C; Press and release the remote buttons the feature ‘3’ to be changed. The siren will chirp and the LED will indicate the new setting. B; Press and release the remote button feature ‘2’ to be changed. The siren will chirp and the LED will indicate the new setting. + Grey wire = two step door unlock output Anti car jacking on Anti car jacking off Shock sensor program mode Two Chirps / LED two flashes Grey wire = trunk/ boot (Channel 3) output One Chirp / LED one pulse Factory Default Setting Exit Programming: Turn Ignition to ‘ON’ position, or waitw for 15 seconds. Three long chirps will confirm exit. 3 2 1 Press remote button Note: The factory default setting is always [1] LED flash, [1] chirp. C; Press and release the remote buttons + corresponding to the feature ‘3’ to be changed. The siren will chirp and the LED will indicate the new setting. B; Press and release the remote button corresponding to the feature ‘2’ to be changed. The siren will chirp and the LED will indicate the new setting. 3. A; Press and release the remote button corresponding to the feature ‘1’ to be changed. The siren will chirp and the LED will indicate the new setting. 2. Push the valet switch 6 times and hold on the 6th push until three short chirps and one long chirp is heard, and then release the valet switch. You are now in the Alarm feature ‘III’ programming mode. 2. Push the valet switch 4 times and hold on the 4th push until two short chirps and one long chirp is heard, and then release the valet switch. You are now in the alarm feature ‘II’ programming mode. corresponding to the 1. Turn the ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds), and leave in the OFF position. 1. Turn the Ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds), and leave in the OFF position. 3. A; Press and release the remote button feature ‘1’ to be changed. ALARM FEATURE “III” PROGRAMMING: ALARM FEATURE “II” PROGRAMMING: 7 8 Note: If 20 seconds of inactivity expire, or the ignition is turned on during the above steps, the unit will exit the programing mode and return to the disarmed mode. Three long chirps will confirm exit. 9. When you are satisfied with the setting, press and buttons simultaneously. One long siren chirp indicates the unit has confirmed the setting. 5. Pressing button on the remote once will increase sensitivity level by one, each time an increase is made the siren will respond with one chirp, while 2 chirp’s indicates the maximum sensitivity setting. 6. Hit the bumper or strong metal part of the vehicle to test the threshold level of the sensor. a). Activate the warn-away (first stage of the shock sensor), the siren will emit a short chirp. b). Activate the full alarm (second stage of the shock sensor), the siren will emit a long chirp. 7. When you are satisfied with the second stage of the shock sensor settings, press and hold and buttons simultaneously for 2 seconds. Two long siren chirps will indicate the unit is ready to accept adjustments of the first stage of the shock sensor (warn-away). 8. Follow the steps 4, 5 and 6 to adjust the warn-away sensitivity. 3. Press and hold button for 2 seconds. One long siren chirp will indicate the unit is ready to accept adjustments of the second stage of the shock sensor (full alarm). 4. Pressing the button on the remote once will decrease the sensitivity level by one, each time a decrease is made the siren will respond with one chirp, while 2 chirp’s indicates the minimum sensitivity setting. 1. Turn the ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds) and leave in the OFF position. 2. Push the valet switch 6 times and hold on the 6th push until three short chirps and one long chirp is heard, and then release the valet switch. You are now in the alarm feature ‘Shock Sensor’ programming mode. ADJUSTING THE SENSITIVITY LEVEL OF THE SHOCK SENSOR 2 Pin Blue 6 Pin White 6 Pin White 2 Pin White 6 Pin White 6. Red Wire: +12V To Constant Battery Source 5. Brown Wire: Positive output To Siren 4. Black Wire: Ground to Vehicle FRAME 3. White Wire: Turn Indicator Relay Output 2. Red / White Wire: Turn Indicator Relay Power input 1. White Wire: Turn Indicator Relay Output A: MAIN 6 PIN WIRE HARNESS: Valet Switch Black Antenna Wire WIRING DIAGRAM LED Indicator Turn Indicator 15A Fuse Main 6 Pin Wire harness Wire harness 6 Pin Door Lock/Unlock 6 Pin Mini Connector 9 Yellow wire 10 D o o r U n lo c k C o n tro l W ire H 7 /2W h ite /G re e n w ire fo r d o o r lo c k c o n tro l (-) in p u t H 7 /3W h ite /B la c k w ire fo r d o o r u n lo c k c o n tro l (-) in p u t +12V Blue / yellow Green / yellow Door Lock Door unlock Blue / white M aster Locking Switch NEGATIVE TRIGGER DOOR LOCK SYSTEM (Factory Door Locking System) B: CENTRAL LOCKING DIAGRAMS H7 B lu e / y e llo w G re e n / y e llo w B lu e / w h ite G re e n / w h ite G re e n / re d B lu e / re d Green/White W ire: (30) - Door Lock Relay Green/Yellow W ire: (87) - Door Lock Relay +12V D oor Lock C o n tro l W ire INSTALLING 4 DOOR LOCK MOTORS (WITH 5-WIRE LOCK MOTOR) Green/ yellow Blue/ yellow Green / white Orange wire White wire To start solenoid 12V Green/ red Blue/ red Blue/ white Green/ white INSTALLING DOOR LOCK MOTORS (2 WIRE) (After market Door Motors) A: CENTRAL LOCKING DIAGRAMS Green/Red W ire: (87a) - Door Lock Relay Blue/Yellow W ire: (87) - Door Unlock Relay Blue/White W ire: (30) - Door Unlock Relay Blue/Red W ire: (87a) - Door Unlock Relay (See central locking diagrams) 30 Cut 85 87a 86 Red wire From ignition switch C: 6PIN DOOR LOCK/UNLOCK WIRE HARNESS: 6. Gray Wire: (-) 200mA Programmable Output Channel 3 / 2 Step Door Unlock. 5. Orange Wire: 200mA Grounded when armed 4. Yellow Wire: To Ignition Switched + 12V 3. Green Wire: Negative Door Pin Switch Input 2. Blue Wire: Instant Trigger Ground Input 1. Violet Wire: Positive Door Pin Switch Input 12V B: 6 PIN MINI CONNECTOR WIRE HARNESS: 11 Door unlock Splic To Slave Door Lock switches + 12V Cut the Existing Unlock Wire Splic X X To Door Lock Cut the Existing Lock Wire +12V M aster Locking Switch 12 Blue/ yellow Green/ yellow Blue/ white Green/ red Blue/ red Green/ white +12V Cut X Compressor Door Switch VACUUM OPERATED DOOR LOCKING SYSTEM Blue/ yellow Green/ yellow Blue/ white Blue/ red Green/ white Green/ red Master Door Lock Switch ALTERNATING DOOR LOCKS Blue / yellow Green / yellow Door Lock Blue / white Green / white POSITIVE TRIGGER DOOR LOCK SYSTEM 30 Blue / Yellow Blue / White Unlock X + 12V Unlock Cut the Unlock Wire 85 +12V x +12V To All Other Door Lock Motors Lock OEM Slave Door Lock Switch Cut the Existing Lock Wire Lock H4 6-Pin Door Lock Wire Harness OEM Door Lock Motor Blue / Yellow Green / Yellow Green / White Blue / White Blue / Red H7/9 Brown Wire X OEM Door Lock Relay Cut Existing Unlock Wire +12V Existing Unlock Wire Unlock To All Other Door Lock Motor Existing Lock Wire Lock OEM Door Master Lock Switch 2 STEP DOOR UNLOCK WIRE CONNECTIONS FOR GROUND SWITCHED DOOR LOCKS x OEM Door Master Lock Cut Existing Unlock Wire Green / Yellow Green / White Blue / Red 87 87A 86 Green / Red OEM Driver's Door Lock Motor H4 6-Pin Door Lock Wire Harness H7/9 Brown Wire + 12V 2 STEP DOOR UNLOCK WIRE CONNECTIONS FOR 5 WIRE ALTERNATING DOOR LOCKS 13 14 H4 6-Pin Door Lock Wire Harness 86 Green / Yellow OEM Driver's Door Lock Motor Blue / Yellow 87 X Existing Pos. Unlock Wire OEM Door Lock Relay + 12V Lock To All Other Door Lock Motors Existing Pos. Lock Wire OEM Door Master Lock Unlock + 12V 85 Cut Existing Unlock 87A 30 Green / White Blue / White Blue / Red H7/9 Brown Wire +12V 2 STEP DOOR UNLOCK WIRE CONNECTIONS FOR POSITIVE SWITCHED DOOR LOCKS 15 Amp 10 Amp 10 Amp 15 mA 10VDC – 16VDC -40 °C – +80 °C (-40 °F – +176 °F ) 433.92 M Hz Z105 (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions. THE FUSION CE-SS200 SECURITY SYSTEM COMPLIES WITH: Note: Remote control range is dependant on weather conditions and alarm installation. Indicator light flash output: Door Lock: Door Unlock: Security system (disarmed): POWER CONSUMPTION: Power supply: Operating temperature: TX Frequency: SPECIFICATIONS: 15