Transcript
Installation taps UTG 1, 2, 3 and 4-way taps • • •
High quality, 1, 2, 3, and 4-way installation taps High return loss Exceeds EN Class A screening requirements (DIN EN 50083-2)
Overview Underground taps are designed for use in CATV area networks, primarily in underground installations. Depending on the type, up to 4 branch cables are connected to a CATV signal line. Technetix UTG taps are available as 1, 2, 3 or 4-way taps with the well known standard attenuations of 10 dB, 15 dB or 20 dB. The taps feature the new optimized frequency response of 5-1500 MHz for up- and downstream. PCB and component connections are in a plastic housing permanently installed. The thermally bonded housing ensures the necessary seal against moisture from the soil and a high degree of stability between cable and connector housing. The cable connectors are made of flexible coaxial cable with fixed RF connectors, therefore contact sleeves 4/20 are used. In addition the modified design of these new Technetix taps achieves a very high screening factor. The new improved design of the Technetix tap is based on the currently applicable specification TLNr. 59753047 and KDG 1 TS 53. With the new transmission range of up to 1500 MHz as well the optimized frequency response, they also meet the demands of Germany’s most important cable operators, providing modern and future-proof technology.
Jan/2015 - Version final 1.1
Technetix Group Limited e:
[email protected] w: www.technetix.com
Installation taps UTG 1, 2, 3 and 4-way taps Specifications MHz Insertion loss (dB)
Tap loss
1-way
2-way
4-way
10 dB 15 dB 20 dB 10 dB 15 dB 20 dB 10 dB 15 dB 20 dB 10 dB 15 dB 20 dB 5-10
1.5
0.6
0.6
2.8
1.5
1.2
4.1
2.4
1.8
5.4
3.2
2.4
10-11
1.1
0.6
0.4
2.2
1.4
0.8
3.4
1.8
1.2
4.8
2.4
1.8
11-300
1.1
0.5
0.4
2.1
1.3
0.8
3.4
1.8
1.2
4.8
2.2
1.5
300-614
1.2
0.6
0.5
2.2
1.4
0.9
3.7
2.1
1.5
5.0
2.4
1.7
614-862
1.3
0.7
0.6
2.3
1.5
1.0
4.0
2.4
1.8
5.3
2.7
2.0
862-1000
1.5
0.9
0.8
2.5
1.7
1.2
4.5
2.9
2.3
5.8
3.2
2.5
1000-1200 1.7
1.1
1.0
2.7
1.9
1.4
5.0
3.4
2.8
6.3
3.7
3.0
1200-1500 1.9
1.3
1.2
3.5
2.6
2.0
6.4
4.3
4.0
7.8
5.0
4.5
5-862
10.0
15.5
20.0
11.0
16.0
20.5
11.5
16.0
20.5
12.5
16.5
21.0
862-1500
11.0
16.5
21.0
12.0
17.0
21.5
12.5
17.0
21.5
13.5
17.5
22.0
Tolerance
± 1.0 dB
MHz
Types
Isolationout/out&TAP/TAP1
Isolation in dB OUT/TAP
TAP/TAP
5-65
all
≥ 20
≥ 30
65-450
all
≥ 30
≥ 40
450-862
all
≥ 25
≥ 35
862-1500
all
≥ 20
≥ 30
Shielding effectiveness
5-1500
Return loss
5-10
≥ 10 dB
10-47
≥ 15 dB + 2.5 dB / Octave
47-1500 Impedance in/out
3-way
≥ 85 dB
≥ 20 dB - 1 dB / Octave 75 Ω
Ordering information
Remarks 1
For 10 dB type - 5-47 MHz ≥ 30 dB; 47-50 MHz ≥ 37 dB Measurements taken at room temperature
Item Name
Articlenumber
UTG-1-10
19007992
UTG-1-15
19007993
UTG-1-20
19007994
UTG-2-10
19007995
UTG-2-15
19007996
UTG-2-20
19007997
UTG-3-10
19007998
UTG-3-15
19007999
UTG-3-20
19008000
UTG-4-10
19008001
UTG-4-15
19008002
UTG-4-20
19008003
© Copyright 2015 Technetix Group Limited. All rights reserved. Thisdocumentisforinformationonly.Featuresandspecificationsaresubjecttochangewithoutnotice.Technetix,theTechnetixlogo,IngressSafe,ModemSafeandcertainother marksandlogosaretrademarksorregisteredtrademarksofTechnetixGroupLimitedintheUKandcertainothercountries.Otherbrandandcompanynamesaretrademarksoftheir respective owners. Technetix protects its technology and designs by registering patents, trade marks and designs in Europe and certain other countries.
Jan/2015 - Version final 1.1
Technetix Group Limited e:
[email protected] w: www.technetix.com