Transcript
Installing the American Dynamics VideoEdge® IP Dome Camera with an Indoor Pendant housing using an EndCap (ROENDC) style mounting The ROENDC End Cap is designed to be used with the RHOSW short wall, RHOLW long wall, and the RHOTR over the roof mounting kits. For information on installing these mounting kits see the relevant instructions provided in the packaging. ●● RHOSW/RHOLW installation guide. 8000-2692-08 ●● RHOTR installation guide. 8000-2629-06
Warnings Please review the following warnings before you install or service the camera dome.
ALWAYS USE: ●● Proper safety equipment for the location and type of installation. ●● Proper lift equipment to reach the installation. ●● Safety features of the lift equipment.
BE SURE: ●● ●● ●●
1 ●● ●● ●● ●●
Electrical power is not connected to the camera when connecting wires. the camera will move when power is applied. Electrical power is not connected to nearby fixtures that you might touch during installation. DO NOT install this dome in hazardous areas where highly combustible or explosive products are stored or used.
What’s in the box Pendant Housing Audio Video cable 2 way power connector, 8 way alarm connector,
Preparing the End Cap Housing 13. Twisting the cables to avoid tension, screw the housing onto the adapter pipe. 14. Keep turning the housing until tight 15. Re-check the level of the dome in the to directions: Re-level if necessary. 16. Route the pigtail cables from the dome through the End Cap. 17. Place any excess cable into the end cap and ensure the O-ring is in place. 18. Using a wrench for tamperproof screws, attach the cover to the End Cap
If a junction box or patch panel is being used then 1. Prepare cabling of sufficient length to ensure connection of the camera to the junction box and to enable easy servicing. If a junction box or patch panel is not being used then, ensure that the appropriate cables are in place for the installation. 2. Remove pipe elbows (if any) and then make a mark 4 cm (1.6 in) from the end of the existing pipe. 3. Slip the cable into the hole of the dust plug and work the plug into the pipe opening.
3
Note: the plug must be fully inserted and must fully seal the opening 4. Thread the two setscrews provided into the adapter pipe. Also, to prevent water intrusion, ensure the adapter pipe has gasket and rubber seal pre-installed. Gasket (seat in groove
Rubber Seal (seat over opening) Setscrew (2) 5. Run cables from the existing pipe through the end cap and out its front
6003-0269-01 2109-0510-02 2109-0779-08
Optional Accessory ●● 12 Vdc Power Brick
2
6. Run the cables from the existing pipe through the end cap and out its front end. 7. Install the end cap as follows: Note: If the marks on the pipe of the mounting structure are missing, scribe a circumference mark 4 cm (1.6in) from the end of the pipe. See step 2.
Screwdriver Pliers Power drill Allen wrench Socket wrench kit with extension (metric) Screwdriver
Before You Begin To ensure a smooth and successful installation, observe the following requirements.
General Requirements ●● ●● ●● ●● ●●
Have electrical work comply with latest national electrical code, national fire code, and all applicable local codes and ordinances. Coordinate work with other trades to avoid interference. Verify existing site conditions and coordinate with the owner’s representative and appropriate utilities as required. Obtain copies of all related plans, specifications, shop drawings and addenda to schedule and coordinate related work. Thoroughly review the project to ensure that all work meets or exceeds the above requirements. Bring alleged discrepancies to the attention of the CCTV Project Coordinator.
Preparing the Videoedge® IP SpeedDome Camera
1. Remove the Videoedge® IP SpeedDome camera from the housing. 2. Gently swivel eyeball to totally expose one of the two slot covers. Caution: Swivelling the eyeball fast may damage gears. 3. Insert small, thin-bladed screwdriver into the space between cover and eyeball. 4. Gently pry off slot cover. 5. Gently swivel the eyeball to totally expose remaining slot cover. With the other cover removed this cover can be easily removed. The SD MicroCard is an optional accessory. It is required for audio clips and to enable emailing or FTP of video files. The maximum size of SD MicroCard that can be used is 2GB. Caution: Disconnect the power before installing or replacing the SD MicroCard.
5606-0070-01
6. Insert the SD MicroCard into the slot as shown if required.
Tools Required ●● ●● ●● ●● ●●
a) Align the arrow on the adaptor pipe with the mark at the top of the pipe assembly. b) Maintaining arrow/line alignment, insert the end cap assembly over the pipe until the rubber sleeve on the adapter meets the circumference mark. Note: to ensure a good seal on the mounting it is recommended that you tighten the two set screws sequentially and evenly and do not over tighten them. c) Tighten the two setscrews using the allen wrench. 8. Check the level of the pipe assembly. If re-leveling is necessary, loosen the two set screws and repeat step 7 a - c. 9. Remove the housing from the packaging. 10. Cut a 30cm (12 in) length of teflon tape. 11. Apply teflon tape to the threads at the top of the housing. 12. Route the cable from the housing through the bottom opening of the end cap and out its front. Caution: take care when threading the housing onto the End Cap to avoid any damage to the cables.
4
Removing the metal adaptor plate
1. Unscrew the 3 retaining screws on the metal adaptor plate 2. Turn the metal adaptor plate anti-clockwise to release it from the housing 3. Slide the adaptor plate down and out of the housing Note: The plate is attached by a safety lanyard to the housing. You are not required to remove this safety lanyard. You may now attach the prepared Videoedge® IP SpeedDome camera to the metal adaptor plate. © 2009 Tyco International Ltd. and its Respective Companies. All Rights Reserved
8200-2613-05 B0
Installing the American Dynamics VideoEdge® IP Dome Camera with an Indoor Pendant housing using an EndCap (ROENDC) style mounting 5
Attaching the Videoedge IP Dome Camera to the Metal adaptor plate
1. The metal adaptor plate has cutouts to allow access for the cables and to allow the cameras heatsink to pass through the adaptor. Using these cutouts as a guide attach the camera to the adaptor plate
2. Secure the metal adaptor plate to the camera by sequentially tightening the three locking screws.
6
Pin # 1
Transmit
2
Transmit
3
Receive
4
N/A or Power if using PoE
5
N/A or Power if using PoE
6
Receive
7
N/A or Power if using PoE
8
N/A or Power if using PoE
Pin #
For ease of installation it is recommended that the cables are attached in the following order. Warning: When connecting wires, ensure that electrical power is not connected to the camera dome. The dome will move when power is applied. Also, ensure electrical power is not connected to nearby fixtures you may come into contact with during the installation. Green 8 way Alarm White 8 way AV cable RJ-45 Ethernet cable Green 2 way DC power cable (Warning: DC only, do not apply AC power)
Ethernet 10BASE-T 100BASE-TX
7
1. Remove the bubble assembly from the package and ensure the bubble is clean and free of debris. 2. Attach the coiled lanyard from the bubble to the threaded stud on the indoor housing using the thumb nut supplied.
Designation
1
Alarm in 1
2
Alarm in 2
3
Alarm in 3
4
Alarm in 4
5
Ground
6
Relay NC
7
Relay C
8
Relay NO
3. Attach the bubble assembly. 4. Align the key on the inside of the bubble assembly with the detent on the edge of the housing. Caution: To maintain the integrity of the gasket seal between the housing flange and the trim ring, do not let the lanyard get caught between these two pieces as you secure the bubble assembly to the housing.
Pin-outs for Audio Video cable Video
Pin#
Color
Designation
1
White
Video Hi
Mic Red
2
Audio Green
Video Shield
3
Green
Audio Hi
4
Yellow
Audio RTN
5
Red
Mic Hi
6
Not Connected
7
Audio Shield
8
Mic Shield
Align the cutout on the metal adaptor plate with the corresponding guide in the housing. (It may help you to align the cutout and guide if you tilt the assembled camera unit as shown.)
Pin outs for connectors Pin #
2 wire DC supply Color
Designation
1
Black
Ground
2
Red
12 Vdc
Attaching the Bubble assembly
Alarm connector pin-out for 8 Way Connector
Attaching the assembled Camera Unit
●● ●● ●● ●●
7. Secure the assembled unit to the housing by sequentially tightening the three locking pins.
RJ-45 Ethernet Interface
5. Slide the assembled camera unit up into the housing until it touches the flange. 6. Maintaining the contact with the flange rotate the assembled unit in a clockwise direction until the locking pins engage
5. Use the drive (taped inside bubble) to tighten the four tamper-proof screws on the bubble assembly. 6. To compress the gasket evenly, tighten each screw in clockwise formation until slight resistance is felt, then retighten each screw again in clockwise formation until all screws are evenly tight. 7. Apply power to the Dome When power is applied, the dome checks its functionality by performing a homing routine during which the camera pans and then either goes to the start point of the “apple peel” pattern or if powered up once before, to the last position in memory. Once the camera stops, the camera is online and is ready to be controlled.
Optional step for Vandal Resistant Installations
7
Attaching the Vandal Resistant Bubble Assembly
1. Remove the vandal-resistant bubble assembly from the package and en sure the bubble is clean and free of debris. 2. Attach the coiled lanyard from the bubble to the outdoor housing. Attach the lanyard to threaded stud on the housing using the thumbnut. 3. Attach the bubble assembly. a. Remove the “CAUTION: Remove slot covers” tag. Ensure the slot covers are removed. b. Align the key on the inside of the bubble assembly with the detent on edge of the indoor housing. c. Secure the bubble assembly to the housing using the four tamperproof screws. Use the drive (taped inside bubble) to tighten the screws.
© 2009Tyco International Ltd. and its Respective Companies. All Rights Reserved
8200-2613-05 B0