Table of contents 1
Description of Device ............................................................................................. 4 1.1 Safety Instructions............................................................................................ 5
2
Preparation and Installation .................................................................................. 6 2.1 Safety information ............................................................................................ 6 2.2 Mounting .......................................................................................................... 7 Operating on the Floor (Upright) ............................................................ 8 2.2.2 Mounting in hanging position ................................................................ 8 2.2.3 Mounting in sideways Position.............................................................. 8 2.3 Securing the Fixture ......................................................................................... 9 2.4 Connections ..................................................................................................... 9 2.4.1 Power Supply........................................................................................ 9 2.4.2 DMX...................................................................................................... 9 2.2.1
3
The Menu Field ..................................................................................................... 10
4
DMX Channel Selection (DMX Protocol)............................................................. 12
5
Maintaining and Cleaning the IMPRESSION X4S ............................................... 16 5.1 Safety regulations .......................................................................................... 16 5.2 Maintenance and Interval (rule-of-thumb) ...................................................... 16 5.3 Changing the Fuse......................................................................................... 17
6
Technical Specifications...................................................................................... 18
7
Dimensions ........................................................................................................... 19
8
Index ...................................................................................................................... 20
GLP
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
3
1 Description of Device
1. Moving head (actively and passively cooled)
1
2. Arm of device 3. LCD-Display/Menu (data entry)
2
4. Base with various connectors, air in/outlets and mounting system
3
5. Fuse holder
5 4
ba se sid e 1
6. Power On/Off 7. DMX- Output (5-pin)
6
7
8. DMX- Input (5-pin) 9. Mains supply (fixed cable)
b a s e s id e 2
8
GLP
9
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
4
1.1
Safety Instructions The IMPRESSION X4Ss is a High-Tech Product. To guarantee a smooth operation, it is necessary to respect the following rules. The manufacturer of this device will not take responsibility for damages through any disregard of the information provided in this manual. Warranty claims also will be voided in the case that the fixture housing is opened. 1. Before powering on the fixture, make sure that the fixtures fans and air inlets are clean and not blocked. 2. Ensure that the fixture head can rotate unhindered throughout its complete range of pan and tilt movement. A safety distance of at least 0.5 m must be maintained between the fixture and any easily inflammable material (e.g. decoration material). 3. Attention! Don’t touch the fixture during the operation. This can cause injuries and/or damages. 4. The fixture doesn’t contain any user serviceable parts. Opening the fixture will void all warranties. 5. It is necessary to wait at least 15 minutes after disconnecting the mains power before handling the fixture.. Pay attention to possible hot parts of the fixture. -- Danger of BURNING -6. Never look directly into the beam of light or into one of the LEDs. Never use optical apertures to observe the beam of light. LED Class 2M. You'll risk serious injury of your eyes and in particular of your retina. Attention: LED Class 2M can cause injuries of your eyes even without optical instruments in front of them or within a distance of less than 0.5m and short exposure time. Hence: Avoid direct radiation into your eyes! 7. To ensure safe operation, follow also the Installation guide described in chapter 2. Operating the IMPRESSION X4S without suitable safety aids like Safety cables or clamps/hooks can increase the risk of an accident and must be avoided. 8. Repair, maintenance, and installation work shall be done by qualified or GLP certified staff only. You need to pay attention to the common rules of technology that are not explicitly mentioned in this manual. 9. Use only original GLP spare parts. Any structural modification of the system will terminate all warranty claims. 10. Please keep this instruction manual for future reference.
GLP
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
5
2 Preparation and Installation 2.1
Safety information The IMPRESSION X4S fixtures from GLP is fitted with a number of planoconvex lenses in a highly efficient collimator cluster. This type of lens can act as a strong magnifying glass. If the rays from a strong light source (such as the sun or another lighting fixture) are directed towards the front of any of these fixtures, then internal damage may occur. In a worst case scenario with a high power light source this can happen very quickly, damaging the fixture internally, potentially melting components or causing an internal fire within seconds. In order to avoid these possible problems please adhere to the following requirements: •
Do not expose the front of a fixture to direct sunlight or any other strong light sources.
•
For outdoor applications during daylight make sure that the front face of any fixture is either shielded or points away from the sun, even when fixtures are not in use.
•
Do not modify the front glass or lenses of any fixture.
These requirements have to be followed regardless of whether a fixture is powered on or off as the magnifying effect is an optical effect and therefore independent from the (electrical) state of the fixture. Especially when working with high powered beam-lights; extreme caution and observance of these safety instructions is mandatory.
Should you have any questions about the operation of your fixture then please contact your local GLP office, or their authorized distributor, a list of which can be found at http://www.glp.de. GLP
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
6
2.2
Mounting The IMPRESSION X4S is fully operational whether it hangs or is mounted to the wall. It can also be operated while standing on the floor. Keep a safety distance of min. 0.5 m towards any easily inflammable materials (decoration etc.).
Pay attention to the regulations of: BGV C1 (former VBG 70), DIN VDE 0711-217 and BGI 810-3. The installation shall be done by qualified staff only.
For the various mounting positions of the IMPRESSION X4S (standing on the floor, sideways or hanging) different connectors are available. Through this a safe and firm installation is assured. You'll find dedicated M10 threads on the bottom side of the fixture 2x safety eyelets 3x M10 which should be used. In (length max.11mm) addition the top of the base is marked with a FRONT arrow allowing consistent orientation during installation.
4x rubber feet Fixture from below GLP
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
7
2.2.1 Operating on the Floor (Upright) The IMPRESSION X4S is fitted with 4x solid rubber feet which allows a stable standing of the fixture. An additional securing is usually not required. Please pay attention to an even and gripping surface.
2.2.2 Mounting in hanging position To operate the IMPRESSION X4S in a hanging position please use a half-coupler (clamp). This can be mounted directly to the bottom side of the fixture. It should be attached centrically with a M10 mm thread bolt (max. length 11mm). Attention: Never use a longer bolt as this may damage the interior of the fixture.
2.2.3 Mounting in sideways Position To operate the IMPRESSION X4S in a sideways position please use two half-couplers (clamps) attached to the bottom side of the base. They should be attached with M10 mm thread bolts (max. length 11mm). This technique is necessary to cope with the torque which accrues in this mounting position. Never use the "Mounting in hanging position" technique described above to fasten the fixture in the sideways position. GLP
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
8
A safe and sound installation can not be assured in this way. In addition this can damage the fixture base.
2x half-couplers 2.3
1x half-coupler
Securing the Fixture Regardless of the mounting method of the IMPRESSION X4S you'll have to use a stipulated safety wire. Attach the safety wire through one of the two holes provided on the base of the fixture and connect it to the primary support structure. Pay attention to a safe and proper fastening. The safety cable must comply with BGI 810-3 (EN 60598-2-17 Section 17.6.6) and be capable of bearing a static suspended load that is ten times the weight of the fixture and all installed accessories.
2.4
Connections 2.4.1 Power Supply ~100-240 Volt AC, 50-60 Hz, earth contact type plug Connected load 130 VA (W) <=> T5A (micro-fuse 5x20mm) Please see printing on the case for the right electronic supply! Disconnect from the mains supply for changing the fuse and use only the above described micro-fuse type. 2.4.2 DMX USITT DMX-512 Standard input/output in 5-pin connectors. Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+] / Pin 4&5 N.C. The DMX- Addressing starts at the DMX- Address [001].
GLP
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
9
3 The Menu Field You’ll find the control board on the side part of the arm. It allows you to make all necessary adjustments of the IMPRESSION X4S. With the Mode-key you get into the main menu. Afterwards you can navigate through the menu with the Up/Down-keys. Push the Enter-key to get in the next menu level or to confirm your settings. Make them and set functions ON/OFF with the Up/Down-keys. Confirm and save it with the Enter-key (the display shows OK). Push the Mode-key to cancel the entry and go back to the main menu.
Mode
Enter
Down
Up
To lock or unlock the keys of the menu field press Mode+Enter+Up simultaneously. MODE - ENTER Level1 DMX Start Address 001
Level 2
Special
Manual DMX
Level 3
Level 4
Remark Set the DMX start address
DOWN - UP
Manual control of all fixture functions Pan Pattern Byte 1 Pattern Zoom Speed Movements Pan/Tilt Movements Special White Temperature Dimmer Shutter White Blue Green Red Color Wheel Tilt
Manual control for Pan (X-movement)
Key code xxxx Display Contrast PWM Frequ. Adj. Pan Offset Tilt Offset LED adjust
Use the code for entering the calibration menu (for authorized persons only)
Manual control for Pattern Byte 1 LED 1 - 7 Manual control for Pattern channel / bank Manual control for Zoom Manual control for Pan/Tilt movements Manual control for Pan/Tilt movements
Manual control for Color temperature Manual control for Dimmer Manual control for Shutter Manual control for White Manual control for blue Manual control for green Manual control for red Manual control for the color wheel Manual control for Tilt (Y-movement)
Adjust
Adjustment for the Display contrast Changes PMW frequency Calibration for Pan-Offset Calibration for Tilt-Offset White adjust Adjust intensity for red channel red White adjust Adjust intensity for blue channel blue White adjust Adjust intensity for green channel green
Clear EEPROM
GLP
German Light Products GmbH
Erase EEPROM memory (Instruction version: 1.1) / from software version: V1.09
10
Diagnose
Diagnose fixture functions
DMX Image Set image if DMX off Save image in memory DMX input Monitor Pan Tilt Pattern Byte 1 Pattern Zoom Speed Movements Pan/Tilt Movements Special White Temperature Dimmer Shutter White Blue Green Red Color Wheel
DOWN - UP
Set DMX Mode
Stores the scene currently sent to the unit Indicates the presently received DMX signal per DMX channel Instantaneous value for Pan Instantaneous value for Tilt Instantaneous value for Pattern Byte 1 Instantaneous value for Pattern channel / bank Instantaneous value for Zoom Speed adjustment for Pan/Tilt movements see item below Instantaneous value for Pan/Tilt movements Instantaneous value for Special Adjustment of the color temperature for WHITE Instantaneous value for Dimmer Instantaneous value for Shutter Instantaneous value for White Instantaneous value for Blue Instantaneous value for Green Instantaneous value for Red Instantaneous value for Color Mixing unit Select the desired DMX Mode
Compressed Mode Normal Mode High-Res. Mode Position feedback Reverse Pan Reverse Tilt Reset
GLP
Activates a stored scene if DMX is off
German Light Products GmbH
Fixture works in "Compressed" mode see also section 4 below Fixture works in "Normal" mode see also section 4 below see Fixture works in "High Resolution" mode also section 4 below Switch automatic position feedback ON/OFF Invert Pan movements: ON/OFF Invert Tilt movements: ON/OFF RESET and new calibration for all functions
(Instruction version: 1.1) / from software version: V1.09
11
4 DMX Channel Selection (DMX Protocol) Normal-Mode 18 DMX channels Channel 1) PANcoarse 2) PAN-fine 3) Tiltcoarse 4) Tilt-fine 5) Color (fixed)
6) Red 7) Green 8) Blue 9) White 10) Shutter
11) Dimmer 12) CTO
13) Special
14) Movement macros GLP
Function
Colors adjustable via RGB Color 01 - Red 1) 1) Color 02 - Amber 1) Color 03 - Warm Yellow 1) Color 04 - Yellow 1) Color 05 - Green 1) Color 06 - Turquoise 1) Color 07 - Cyan Color 08 - Blue 1) Color 09 - Lavender 1) Color 10 - Malve 1) Color 11 - Magenta 1) Color 12 - Pink 1) White - CTO White White - CTB Rainbow Effect Stop 2) Rainbow Effect 3) Random colors Color mixing system - Red Color mixing system - Green Color mixing system - Blue Color mixing system - White Shutter closed Shutter pulse random Up-dimming then Shutter closing (random patterns) Shutter open then down-dimming (random patterns) Up-dimming then down-dimming (random patterns) Strobe effect pause Strobe effect slow - fast Shutter open Dimmer No CTO Continuous color temperature correction Pattern Block 1 channel 17 Change PWM frequency RESET No macros Movement Size Phase PAN 1 0°
German Light Products GmbH
Time and Value
DMX
HEX
%
0..255
00..FF
0..100
0..255 0..255
00..FF 00..FF
0..100 0..100
slow – fast
0..255 0..7 8..15 16..23 24..31 32..39 40..47 48..55 56..63 64..71 72..79 80..87 88..95 96..103 104..111 112..119 120..127 128 129..223 224..255 0..255 0..255 0..255 0..255 0..15 16..47
00..FF 00..07 08..0F 10..17 18..1F 20..27 28..2F 30..37 38..3F 40..47 48..4F 50..57 58..5F 60..67 68..6F 70..77 78..7F 80 81..DF E0..FF 00..FF 00..FF 00..FF 00..FF 00..0F 10..2F
0..100 0..2..5 3..5.5 6..8.5 9..12.5 13..15.5 16..18.5 19..21.5 22..24.5 25..27.5 28..30.5 31..34.5 35..37.5 38..40.5 41..43.5 44..46.5 47..49.5 50 51..88 89..100 0..100 0..100 0..100 0..100 0..5.5 6..18.5
slow – fast
48..79
30..4F
19..31
slow – fast
80..111
50..6F
32..43
slow – fast
112..143
70..8F
44..56
5s - 0.1s 1 Hz - 10 Hz
160..199 A0..C7 200..239 C8..EF 240..255 F0..FF 0..255 0..FF 0..7 0..07
63..77 78..94 95..100 0..100 0..2.5
3200K 5600K 7200K slow - fast slow - fast 0 - 100% 0 - 100% 0 - 100% 0 - 100%
0 - 100% Applicable for ALL colors
8..255
08..FF
3..100
0..3 100..200 250..255 0
00..03 64..C8 FA..FF 00
0..1 40..78 98..100 0
01..01
01..01
0.5
Use "Speed" to adjust
(Instruction version: 1.1) / from software version: V1.09
12
Channel
Function
Time and Value 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4
15) Speed Pan/Tilt
16) Zoom 17) Pattern
18) Pattern Byte 1
90° 180° 270° PAN 0° 90° 180° 270° PAN 0° 90° 180° 270° PAN 0° 90° 180° 270° TILT size / phase see PAN PAN / TILT size / phase see PAN PAN / TILT (inverse) size / phase see PAN Circle size / phase see PAN Circle (inverse) size / phase see PAN Lying eight size / phase see PAN Random movement size / phase see PAN Pan/Tilt movement speed from controller Pan/Tilt, slow – fast Use this channel also for the speed of the movements (channel 14). Wide - narrow (spot) No pattern Pre-defined patterns Activates direct access to LED Pattern Direct access to Pattern of LED 1..7
DMX
HEX
%
02..03 02..03 04..05 04..05 06..07 06..07 08..09 08..09 10..11 0A..0B 12..13 0C..0D 14..15 0E..0F 16..17 11..11 18..19 12..13 20..21 14..15 22..23 16..17 24..25 18..19 26..27 1A..1B 28..29 1C..1D 30..31 1E..1F 32..63 20..3F 64..95 40..5F 96..127 60..7F 128..159 80..9F 160..191 A0..BF 192..223 C0..DF 224..255 E0..FF
1.0 1.7 2.5 3.3 4.1 4.9 5.7 6.5 7.3 8.0 8.8 9.6 10.4 11.2 12 13..25 26..37 38..50 51..62 63..75 76..87 88..100
0..1
00..01
0..0..5
02..255
02..FF
1..100
0…255 00…FF 0..2 00..02 03..253 03..FD 254..255 FE..FF 0…255 00…FF
0…100 0..1 2..99 100 0…100
Compress-Mode 14 DMX channels Channel 1) PANcoarse 2) PAN-fine 3) Tiltcoarse 4) Tilt-fine 5) Color (fixed)
GLP
Function
Colors adjustable via RGB Color 01 - Red 1) 1) Color 02 - Amber 1) Color 03 - Warm Yellow 1) Color 04 - Yellow 1) Color 05 - Green 1) Color 06 - Turquoise 1) Color 07 - Cyan 1) Color 08 - Blue
German Light Products GmbH
Time and Value
DMX
HEX
%
0..255
00..FF
0..100
0..255 0..255
00..FF 00..FF
0..100 0..100
0..255 0..7 8..15 16..23 24..31 32..39 40..47 48..55 56..63 64..71
00..FF 00..07 08..0F 10..17 18..1F 20..27 28..2F 30..37 38..3F 40..47
0..100 0..2.5 3..5.5 6..8.5 9..12.5 13..15.5 16..18.5 19..21.5 22..24.5 25..27.5
(Instruction version: 1.1) / from software version: V1.09
13
Channel
Function
Time and Value
DMX
HEX
%
72..79 80..87 88..95 96..103 104..111
48..4F 50..57 58..5F 60..67 68..6F
28..30.5 31..34.5 35..37.5 38..40.5 41..43.5
112..119
70..77
44..46.5
120..127
78..7F
47..49.5
slow - fast slow - fast
128 129..223 224.255 0..255 0..255 0..255 0..255 0..15 16..47 48..79
80 50 81..DF 51..88 E0..FF 89..100 00..FF 0..100 00..FF 0..100 00..FF 0..100 00..FF 0..100 00..0F 0..5.5 10..2F 6..18.5 30..4F 19..31.5
slow - fast
80..111
50..6F
32..43
slow - fast
112..143
70..8F
44..56
5s .. 1s 1 Hz .. 10 Hz
144..199 200.239 240...249 251..255 0..255 0…255 0..3 100..200 250..255 0..2 03..253
A0..C7 57..77 C8..EF 78..94 F0..F9 95..97.5 FB..FF 99..100 0..FF 0..100 00…FF 0…100 00..03 0..1 64..C8 40..78 FA..FF 98..100 00..02 0..1 03..FD 2..99
1)
Color 09 - Lavender 1) Color 10 - Mauve 1) Color 11 - Magenta 1) Color 12 - Pink White - CTO White White - CTB
6) Red 7) Green 8) Blue 9) White 10) Shutter
11) Dimmer 12) Zoom 13) Special
14) Pattern
Rainbow Effect Stop 2) Rainbow Effect 3) Rainbow Effect, random colors Color mixing system - Red Color mixing system - Green Color mixing system - Blue Color mixing system - White Shutter closed Random Pulse effect Up-dimming then Shutter closing (random patterns) Shutter open then down-dimming (random patterns) Up-dimming then down-dimming (random patterns) Strobe effect pause Strobe effect, slow - fast Shutter open Shutter open Dimmer Wide - narrow (spot) Pattern Block 1 channel 14 Change PWM frequency RESET No pattern Pre-defined patterns
Color temperature 3200K Color temperature 5600K Color temperature 7200K slow - fast slow - fast 0 - 100% 0 - 100% 0 - 100% 0 - 100%
0 - 100%
High Resolution (Extended) -Mode 19 DMX Channels Channel 1) PANcoarse 2) PAN-fine 3) Tiltcoarse 4) Tilt-fine 5) Redcoarse 6) Redfine
GLP
Function
Color mixing system – Red Color mixing system – Red-Low
German Light Products GmbH
Time and Value
0 - 100%
DMX
HEX
%
0..255
00..FF
0..100
0..255 0..255
00..FF 00..FF
0..100 0..100
0..255 0..255
00..FF 00..FF
0..100 0..100
0..255
00..FF
0..100
(Instruction version: 1.1) / from software version: V1.09
14
Channel
Function
Time and Value
DMX
HEX
%
7) Greencoarse 8) Greenfine 9) Bluecoarse 10) Bluefine 11) Whitecoarse 12) Whitefine 13) Shutter
Color mixing system – Green
0 - 100%
0..255
00..FF
0..100
0..255
00..FF
0..100
0..255
00..FF
0..100
0..255
00..FF
0..100
0..255
00..FF
0..100
0..255
00..FF
0..100
slow - fast slow - fast
0..15 16..47 48..79
00..0F 10..2F 30..4F
0..5.5 6..18.5 19..31.5
slow - fast
80..111
50..6F
32..43
slow - fast
112..143
70..8F
44..56
5s - 1s 1 Hz - 10 Hz
144..199 200..239 240...249 251..255 0..255
A0..C7 57..77 C8..EF 78..94 F0..F9 95..97.5 FB..FF 99..100 0..FF 0..100
Color mixing system – Green-Low Color mixing system – Blue
0 - 100%
Color mixing system – Blue-Low Color mixing system – White
0 - 100%
Color mixing system – White-Low
Shutter closed Random Pulse effect Up-dimming then Shutter closing (random patterns) Shutter open then down-dimming (random patterns) Up-dimming then down-dimming (random patterns) Strobe effect pause Strobe effect, slow - fast Shutter open Shutter open 14) Dimmer- Dimmer coarse 15) Dimmer- Dimmer - Low fine 16) Zoom Spot - Flood 17) Special Pattern Block 1 channel 18 Change PWM frequency RESET 18) Pattern No pattern Pre-defined patterns Activates direct access to LED Pattern 19) Pattern Direct access to Pattern of LED 1..7 Byte 1 1)
0 - 100%
0..255
0..FF
0..100
0…255 00…FF 0…100 0..3 00..03 0..1 100..200 64..C8 40..78 250..255 FA..FF 98..100 0..2 00..02 0..1 03..253 03..FD 2..99 254..255 FE..FF 100 0…255 00…FF 0…100
The predefined colors can be used as start-colors for the Rainbow effect. Please select first a
desired start-color before you activate the rainbow effect. All IMPRESSION X4S will then start from that color and will execute the rainbow effect synchronously. Different IMPRESSION X4S can have different start-colors but will still execute the rainbow effect synchronously. If you choose a color different from the ones marked with 1) in the tables above the rainbow start-color will be red. 2)
Rainbow-effect Stop will pause this function. After resuming the rainbow-effect will be continued from the current color.
3) 1)
The Rainbow-effect will run synchronously only if started from one of the predefined colors (see also before).
GLP
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
15
Locking and unlocking the Control Panel Please lock and unlock the control panel by pressing the menu keys MODE & ENTER & UP at the same time.
Additional Display Indications As a default you'll find the following additional information in the first row of the LCD display:
Vxx/xx/xx/xx/x (e.g. V1.09/10/16/NN/NS) NS ( DMX Mode = Normal / Dimmer Mode = Soft) NN ( Pan Mode =Normal; Tilt Mode = Normal) 16 = Pan/ Tilt Driver Version 10 LED driver version 1.09 Main CPU version
5 Maintaining and Cleaning the IMPRESSION X4S The IMPRESSION X4S is a fixture of very low maintenance. It is only necessary to clean the air inlets and outlets as well as the optical LED lenses from time to time. For safe operation it is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build up on, or within the fixture. Otherwise the fixture's light-output will be significantly reduced or damages can occur. Regular cleaning will not only ensure the maximum light-output, but will also allow the fixture to operate reliably throughout its life. A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances should alcohol or solvents be used! 5.1
5.2
Safety regulations •
Pull out the mains power plug!
•
Wait min. 15 minutes after disconnecting power to allow the fixture to cool down.
Maintenance and Interval (rule-of-thumb) The contamination of the fixture depends on the environment details. Hence no general guidelines can be given. The intervals given below are only suggestions from our experience.
GLP
Position
Interval
In this way
LED reflector and optical system
weekly
soft brush /lint-free cloth
Fan and air channel
monthly
vacuum cleaner, airbrush, etc.
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
16
Attention: • Never let optical parts come into contact with oil or fat. • Before running the fixture wait until all parts are dry. • Never tough lenses with bare fingers.
5.3
Changing the Fuse Follow the safety regulations as described above! The micro-fuse holder (2) is located on the topside of the base. In order to attain access you first need to remove one of the two plastic side covers of the fixture arm. Open the two screws no. 1 shown in the picture below. Replace the fuse with one with the exact rating as printed in this manual or the body of the fixture. Never use a different one! Attach the side cover again before operating the fixture.
1 2 1
2
GLP
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
17
6 Technical Specifications Power supply Power consumption 130 VA (Watt) Power Input ~100-240 V AC, 50-60 Hz (wide range input) Fuse protection Micro-fuse 5x20 mm, T5A Operational Parameters Max. Ambient 5° - 45°C (integrated overheating switch) Temperature Mounting Position Any (see relevant chapter) Lighting System - Additive Color mixing LED Type 7 x Osram Ostar RGBW multi-chip Lifetime 50,000 h Wavelength optimized for maximum presentable color space Optical System Full RGBW / High efficient Collimator cluster Shutter / Dimmer (8/16 Bit) Strobe- Effect with variable speed between 1 - 10 flashes per second, Random-Strobe, PulseEffects Continuous Dimmer 0 - 100% Zoom 7 to 50 degree continuous zoom Optical Patterns Several hundred pre-defined beam patterns with direct access and manipulation DMX Control Standard USITT DMX-512, 5-pin XLR; [+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 1 / Pin 4&5 N.C. Die DMX- Addressing starts at the DMX channel [001]. Pan / Tilt (8/16 Bit) Pan- movement 660° in min. 3,2 seconds (Position Feedback) Tilt- movement 300° in min. 1,5 seconds (Position Feedback) Weights and Measures Base only ∅165,5 mm Total width of fixture 224 mm Hight (head vertical) 323mm (incl. base) Weight (net) 5.5 kg
GLP
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
18
7 Dimensions
3x M10 (length max.11mm)
GLP
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
19
8 Index B
Mounting in sidewise Position........................ 8 Mounting on the Floor ................................... 8
beam-lights.................................................. 6 BGV C1 ........................................................ 7
N
C
Normal-Mode ............................................. 12
Cleaning...................................................... 16 Compress-Mode ........................................ 13
O
D Danger of BURNING.................................... 5 Description of Device .................................... 4 Dimensions ................................................. 19 DIN VDE 0711-217 ....................................... 7 Display Indications ................................ 16 DMX ............................................................. 9
Optical parts .............................................. 17
P Pan- Movement........................................... 18 plano-convex lenses...................................... 6 Power Supply .............................................. 9
R RESET........................................................ 12
E
S
e-mail............................................................ 1 EN 60598-2-17.............................................. 9 Enter-key .................................................. 10
High Resolution (Extended) -Mode........... 14
Safety distance ............................................. 7 Safety information ......................................... 6 Safety Instructions......................................... 5 Secure the Device ....................................... 9 Software Version........................................... 1 sunlight ......................................................... 6
I
T
Instruction Version ........................................ 1 Internet ......................................................... 1
Technical Specifications........................... 18 Tilt- Movement ............................................ 18
L LED Class 2M .............................................. 5
U Up/Down-keys.......................................... 10
M
V
Maintenance ............................................... 16 Menu Field .................................................. 10 Micro-fuse ..................................................... 9 Mode-key .................................................. 10 Mounting...................................................... 7 Mounting in hanging Position......................... 8
VBG 70 ......................................................... 7
H
GLP
German Light Products GmbH
W Warranty claims ............................................ 5 Weights and Measures................................ 18
(Instruction version: 1.1) / from software version: V1.09
20
GLP
German Light Products GmbH
(Instruction version: 1.1) / from software version: V1.09
21
RGBW Beam opening (m) 4,807 lx
11,189 lx
2
1
0
7°
1
2 Distance (m) 0 0
3
5
0.37
0.61
1,587 lx
692 lx
Diameter (m)
R Beam opening (m) 2
1
0
7°
1
2 Distance (m) 0
3
0
0.37
5 0.61
Diameter (m)
G Beam opening (m) 1,829 lx
4,260 lx
2
1
0
7°
1
2 Distance (m) 0 0
3
5 0.61
0.37
Diameter (m)
B Beam opening (m) 230 lx
518 lx
2
1
0
7°
1
2 Distance (m) 0
3
0
0.37
5 0.61
Diameter (m)
W Beam opening (m) 2,341 lx
5,497 lx
2
1
0
7°
1
2 Distance (m) 0 0
3 0.37
5 0.61
Diameter (m)
RGBW Beam opening (m) 211 lx
482 lx
3 2 1 0
50°
1 2 3 Distance (m) 0 0
3
5
2.8
4.66
70 lx
30 lx
Diameter (m)
R Beam opening (m) 3 2 1 0
50°
1 2 3 Distance (m) 0
3
0
2.8
5 4.66
Diameter (m)
G Beam opening (m) 79 lx
179 lx
3 2 1 0
50°
1 2 3 Distance (m) 0 0
3
5
2.8
4.66
23 lx
10 lx
Diameter (m)
B Beam opening (m) 3 2 1 0
50°
1 2 3 Distance (m) 0
3
0
2.8
5 4.66
Diameter (m)
W Beam opening (m) 104 lx
235 lx
3 2 1 0
50°
1 2 3 Distance (m) 0 0
3 2.8
5 4.66
Diameter (m)
Appendix A
Pattern Sheet
e-mail:
[email protected] Internet: http://www.glp.de
DMX Channel 17 (Normal Mode) Value
Pattern
Value
Pattern
Value
DMX
000
DMX
014
DMX
028
DMX
001
DMX
015
DMX
029
DMX
002
DMX
016
DMX
030
DMX
003
DMX
017
DMX
031
DMX
004
DMX
018
DMX
032
DMX
005
DMX
019
DMX
033
DMX
006
DMX
020
DMX
034
DMX
007
DMX
021
DMX
035
DMX
008
DMX
022
DMX
036
DMX
009
DMX
023
DMX
037
DMX
010
DMX
024
DMX
038
DMX
011
DMX
025
DMX
039
DMX
012
DMX
026
DMX
040
DMX
013
DMX
027
DMX
040
Pattern
Orientation: Patterns are show when looking at the front of a standing fixture; Head faced in direction of fixtures front label: DMX Pan @ 128; Tilt @ 30; Zoom @ 255 GLP German Light Products GmbH
Version 1.01
2
GLP German Light Products GmbH
Version 1.01