Preview only show first 10 pages with watermark. For full document please download

Instruction Manual

   EMBED


Share

Transcript

TABLE OF CONTENTS INSTRUCTION MANUAL Non-Contact Infrared Thermometer Model : KI-8280 Safety Instructions....................................1 Device Description and Intended Use.......3 About Body Temperature..........................4 Device and Display Overview....................4 Quick Start.............................................5 Explanation of Symbols............................6 Battery Installation....................................7 Setting......................................................8 Changing Modes/Setting.......................8 Setting °C or °F Scale..........................11 Memory Functions.............................11 Use.......................................................12 Measurement Consideration..............12 Taking a Measurement......................13 Cleaning................................................14 Care and Storage...................................14 Product Specification.............................15 Troubleshooting.....................................16 Warranty................................................17 SAFETY INSTRUCTIONS WARNING 1. Read the entire instruction manual before trying to operate the device. 2. The device is delivered non-sterile; please clean the device before measuring. 1 SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS 3. Stop using the device if malfunctions appear or if it operates abnormally. 4. Children should not use the device without the supervision of an adult. 5. Do not use the device when flammable materials are around. 6. Do not place the device on scarred tissue, open wounds or abrasions. 7. S o m e m e d i c a t i o n s m a y c a u s e a rise in skin temperature which can consequently lead to incorrect measurements.. 8. Taking a measurement after skin has been exposed to an extreme condition such as direct exposure to sunlight, fireplace/ heater or air conditioner flow, may lead to incorrect readings. 9. If the device has been kept or stored in extreme temperatures, wait at least one hour for the device to return to room temperature before measuring. lower than the room temperature, a false reading may occur. 5. To ensure the best performance of the device, please follow the Product Specification (on pg. 15) “Storage Environment” regarding temperature and humidity ranges for storing the device. 6. Dispose of the device and batteries according to your local regulatory or environmental protection agency. 7. For maximal performance of the device, we recommend a regular check up and device calibration every two years. CAUTION 1. Do not scrape or scratch the Sensor Lens as it will hamper the effectiveness of the device. 2. Do not dismantle the device except when replacing the batteries. 3. Wait at least thirty minutes after exercising, bathing or eating before taking a measurement. 4. If the subject’s body temperature is 2 DEVICE DESCRIPTION AND INTENDED USE The non-contact infrared thermometer is an electronic device designed to absorb the infrared from human body to detect your temperature. It is intended to measure the human body temperature for infants and adults without contact to human body. It can be used by consumers in household environment and doctor in clinic as reference. 3 ABOUT BODY TEMPERATURE A person’s normal body temperature can range from 35.5°C to 37.8°F (95.9°Cto 100.0°F) throughout the day. We recommend taking your temperature at different times during the day when you are NOT sick. This will give you a preliminary reference to know what your normal temperature is and how it fluctuated during a normal day. Then, when you feel sick or discomfort, knowing this will provide an index for a reliable diagnosis of a fever. DEVICE AND DISPLAY OVERVIEW EXPLANATION OF SYMBOLS Display Overview Waiting for Setting Measuring Beeper On/Off Offset Adjustment Low Battery Power Off Type BF Applied Part Quick Start DEVICE AND DISPLAY OVERVIEW Device Overview 4 1. Install battery into the device. Make sure the polarity (+ and -) of the battery matches as shown in the battery compartment. 2. P r e s s a n d r e l e a s e t h e P O W E R button, you will hear a short beep. The measuring process will begin after the hourglass disappears, you hear two short beeps and either °C or °F appears. 3. Aim the Probe toward the forehead or object approximately 5cm from surface, then press and release the POWER Button to record the measurement. 4. Read the temperature on the display. 5 BATTERY INSTALLATION WARNING 1. U s e o n l y s a m e t y p e o f a l k a l i n e batteries to avoid incompatibility. 2. Replace with 2 new AAA batteries at the same time when the low battery indicator appears. 3. The memories will be erased after replacing the batteries. 4. Remove the batteries if the device is not likely to be used for a long period of time. 5. Do not dispose of battery in a fire. The battery may explode. Warning and Caution MMYY Lot Number composed by month(M) and year(Y) of manufacture Manufacturer Authorized Representative in the European Community 6 1. Remove the battery cover to insert batteries. 2. C o n f i r m t h e p o l a r i t y ( + a n d - ) o f batteries is correct as indicated inside the compartment and insert batteries accordingly. 3. Replace the battery cover. 7 SETTING SETTING SETTING Changing Modes/Settings Object temperature mode The device has four modes/settings: 1. Forehead mode 2. Object temperature mode 3. Beeper On/Off setting 4. Offset setting The default mode is Forehead mode. This mode is intended to measure the temperature of object surface. This mode is not intended for determining human body temperature. 1. Press and release the POWER Button to turn on device. 2. Press and hold the Memory/Mode Button firmly for about 3 seconds. 3. Continue to press and release the Memory/Mode Button to switch between the four modes/settings. Forehead mode This mode is intended to measure the temperature of forehead. 1. When switching between the four modes/settings, simply stop pressing the button when the screen show . 2. The device is now ready to measure forehead temperature. Refer to USE section on page 12 under Measurement Consideration. Carefully read and follow these instructions. 8 1. When switching between four modes/ settings, simply stop pressing the button when the screen shows . 2. The device is now ready to measure the surface of object temperature. Beeper On/Off The default for beeper is ON. You may switch it off to avoid disturbing the patient or others. 1. When switching between the four modes/settings, simply stop pressing the button when the screen shows . 2. After the disappears, the device will show on. Press and release the Memory/Mode Button to show OFF. Press the POWER Button to confirm sound is off. 3. To turn the sound back on, repeat step 1 above. 4. After the disappears, the device will show OFF. Press and release the 9 SETTING Memory/Mode Button to show on. Press the POWER Button to confirm sound is on. Offset Setting The device is capable to convert measured forehead temperature reading to oral temperature automatically. You can apply this mode as a reference temperature to other body sites such as rectal, axillary, and auricular. Please use other thermometer to measure your rectal, axillary or auricular temperature to confirm the temperature difference. Offset default is zero (off). Table 1 Body Sites Oral Rectal Axillary Auricular Normal Temperatures 35.5°C ~37.4°C (95.9°F ~99.3°F) 36.2°C ~37.9°C (97.1°F ~100.2°F) 35.0°C ~37.0°C (95°F ~98.6°F) 35.7°C ~37.9°C (96.2°F ~100.2°F) 1. When switching between the four modes/settings, simply stop pressing 4. It increases 0.1°C (0.2°F) by pressing the offset manually. 5. Press and release the Memory/Mode Button to turn the offset off. 6. The device will beep twice indication it is ready to begin a new measurement. Setting °C or °F Scale 1. You may only set/reset the °C or °F scale when the device in Forehead mode or Object mode. 2. After device is powered on, press and release the Memory/Mode button, then immediately press and release the Power Button to switch the temperature scale. 3. Device is now ready to measure a temperature. 4. Repeat step 2 above to switch back and forth. Memory Functions 2. Press the Memory/Mode Button to start offset alignment when symbol disappears. 3. Press the POWER Button to increase offset within range from +1°C to -1°C (+2°F to -2°F). Recalling Memories 1. Memory recall can only be used when the device is in Forehead mode or Object mode. 2. After device has been powered on, simply press and release the Memory/ Mode Button to show readings stored in memory. 10 11 the button when the screen shows . SETTING 3. When finished viewing memory, you may use the device as explained in #3 of Quick Start (pg.5). Deleting Memories Data stored in the memory will disappear after replacing the batteries. USE Measurement Consideration CAUTION 1. Forehead site must be dry and clean, free of sweat and cosmetics prior to taking measurement. 2. Hair should be held back from forehead site before taking measurement. Aim the probe center at the temple (around 2 cm above eyebrow tail) or object surface. Keep the probe away from skin or object surface around 5cm. 12 USE Taking a Measurement 1. Press and release the POWER Button to turn on the device. 2. A l l s y m b o l s s h o u l d appear on the display. 3. Aim the Probe toward the forehead or object, approximately 5cm from surface, then press and release the POWER Button to record the measurement. 4. The measurement is complete when you hear “Di Di”-“Di Di” sounds. 5. Yo u c a n t a k e n e x t m e a s u r e m e n t instantly. 6. The temperature and back light color shows on the display. 7. The color of the back light is determined by measurement reading. Please refer to Table 2. Table 2 USE 9. The device will automatically power off after 60 seconds of no use. CLEANING 1. Use a cloth dampened with water or neutral detergent to clean and dry the device and Lens. 2. Do not use thinner, benzene, and other harsh cleaners for cleaning the device. 3. Do not immerse the device in water or liquid of any kind. The device is not water proof. CARE AND STORAGE PRODUCT SPECIFICATION Measurement Sites Measurement Distance Measurement Time Display Resolution Measurement Scale Forehead and Object Warranty 1 year Classification Internally powered equipment Type BF Applied Part 3 ~ 8cm 1 second 0.1°C (0.1°F) °C / °F Forehead mode : 32.2 ~ 43.3°C (90 ~ 110°F) Measurement Range Object mode : 0 ~ 100°C (32 ~ 212°F) Forehead mode : 32.2 ~ 43.3°C (90 ~ 110°F) Accuracy ±0.2°C(0.4°F) Object mode : 0 ~ 100°C (32 ~ 212°F) ± 1°C (2°F) Memory 10 sets Auto Shut Off After 60 seconds Operation 10 ~ 40°C (50 ~ 104°F) Environment 15 ~ 95%RH (non condensing) -25 ~ +55°C (-13 ~ +131°F) Storage Environment 15 ~ 95%RH (non-condensing) Power Source 2 AAA 1.5Volt batteries Battery Life Approx. 1000 measurement cycles 138 x 90 x 45 mm Dimension ( 5.43 x 3.54 x 1.77 in ) Weight 132g (4.66oz) including batteries 8. In Forehead Mode Only: The device will continuously beep a fever alarm if the temperature reading is over 37.5°C (99.5°F). 1. DO NOT drop or crush the device. It is not shock proof. 2. DO NOT dismantle or attempt to modify the device. 3. DO NOT store the device in an extreme environment with direct sunlight, very high or low temperatures or in a place with high moisture/humidity or dust. 4. Please contact your local agent or distributor if the device does not function as described in this manual. This device complies with all requirements of ASTM E1965-98 Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature, EN 12470-5 Clinical thermometers - Part 5 : Performance of Infra-red ear thermometers (with maximum device) 13 14 15 Temperature Reading Back Light Color °C °F T ≦ 37.1 T ≦ 98.9 Green 37.2 ≦ T ≦ 37.4 99 ≦ T ≦ 99.4 Yellow T ≧ 37.5 T ≧ 99.5 Red TROUBLESHOOTING The reading is over 43.3°C (110°F). Please wait a few minutes and measure again. The reading is under 32.2°C (90°F). Please wait a few minutes and measure again. The ambient temperature i s o u t o f th e Ope r ation Environment range. Please use the device in an ambient temperature of 10°C to 40°C (50°F to 104°F). WARRANTY Warranty: The device comes with a one year warranty if it is operated under normal circumstances without evidence of tampering. See exclusions below. Warranty exclusions: 1. If user does not properly operate the device according to the instructions as described in this manual. 2. If the device shows signs of tampering or attempted modification. 3. Improper handing, such as dropping, liquid or cleaner damage. 4. Natural disasters (such as fire, flood, earthquake, thunder strike). 5. If you do not have a receipt or proof of purchase showing date of purchase. The device self-diagnostic is failed. Please contact the distributor. REV. 20111213 16 PN. 17