Preview only show first 10 pages with watermark. For full document please download

Instruction Manual For Frsky S.port Dashboard

   EMBED


Share

Transcript

www.frsky-rc.com www.frsky-rc.com Instruction Manual for FrSky S.Port Dashboard 1. Introduction 1.1 Overview: Earphone Part Rotate Switch System Set Units metric or imperial (selectable), fahrenheit or celcius (selectable) Contrast adjust the contrast of the screen Volume adjust the volume of the voice Log Interval data log period (0.1s, 0.5s, 1s, 2s, 5s selectable) Time Zone -11 to 12 time zone selectable (”-” is west and “+ ”is east) Page Power Switch use “rotate switch” to choose, short press “rotate switch” to change the setting Alarm (see detailed chart below) USB Port + S.Port TF Card Slot 1.2 Specifications: Model Names: FSD (FrSky S.Port Dashboard) Compatibility: FrSky X Series Telemetry Modules Voltage Range: 4.8~6V Dimension: 75*50*13.8mm Pixel: 128*64 1.3 Features: 1) Show all connected sensors data; 2) Capable of programming alarm thresholds and system settings; 3) Set Physical ID and Group Number for S.Port sensors; 4) Firmware upgradeable for all S.Port products. 2. Installation Connect FrSky FSD to the S.Port on FrSky X series telemetry module (S.Port, VCC, GND) by the provided cable. 3. Screen Structures Use “rotate switch” to choose, short press “rotate switch” to confirm, short press “page” to the next page, hold “page” for 1 second to go back to previous screen. Alarm Sensor Direction Unit Height Variometer > 10m HeightC Variometer > 10m A1 Receiver < 0.1V A1C Receiver < 0.1V A2 Receiver < 0.1V A2C Receiver < 0.1V A3 S.Port2UART < 0.1V A3C S.Port2UART < 0.1V A4 S.Port2UART < 0.1V A4C S.Port2UART < 0.1V RxBat Receiver < 0.1V RxBatC Receiver < 0.1V SWR Module > SWRC Module > RSSI Receiver < RSSIC Receiver < Note: “C” after the alarm name means “critical”. 3.1 Main screen: SYSTEM System settings VOICES Settings SYSTEM DATA UPDATE Upgrade S.Port devices VOICES IDSET UPDATE INFO DATA Telemetry data display IDSET Set phyID and GNum for S.Port sensors INFO Firmware and Eeprom version Sensor Set RPM Sensor blade Anolog Sensor Volt ratio GPS Sensor Flvss Sensor 3.2 SYSTEM screen: *System Set Units: metric celcius Contrast: Volume: Log Interval: 1s Time Zone: 000 Alarm: Height Dis < 000 *S e n so r S e t RP M S e n so r b l a d e : 0 2 A n o l o g S e n so r Vo l t r a ti o : 04 04 04 04 04 G P S S e n so r E n a b l e d Fl vss S e n so r E n a b l e d + + Set the blade numbers for RPM Sensor Voltage Division Ratio for A1, A2, A3, A4, RBat Enable or Disable the GPS data screen (Page 4 of DATA screen) Enable or Disable the Lipo Voltage data screen (Page 5 of DATA screen) Follow the steps below to change “System Set” and “Sensor Set”: Step 1: Short press “rotate switch” to open “system set”; Step 2: Use “rotate switch” to choose the position you want to change; Step 3: Short press “rotate switch” to change the settings. 3.3 VOICES screen: Website:www.frsky-rc.com FrSky Electronic Co., Ltd E-mail:[email protected] Technical Support: [email protected] Website:www.frsky-rc.com FrSky Electronic Co., Ltd E-mail: [email protected] Technical Support: [email protected] www.frsky-rc.com www.frsky-rc.com Voice Set Select SWR VA RIO 2 .fr k P l s co n n e ct d e vi ce ! S e a r ch i n g .... 5S RSSI RBat A1 A2 A3 A4 Valt Vspd CUR1 Vcu1 TEM1 UPDATE Voice Set Select Voice can be set to “All off”, “All on”, “Select” 5S Time interval for the voice announcement (5s, 10s, 20s, 30s, 1m, 1.5m, 2m selectable Step 7: After the screen shows “Device found! Please click UPDATE”, choose and short “UPDATE” to confirm update or “BACK” to quit the update; VA RIO 2 .fr k De vi ce fo u n d ! P l e a se cl i ck UP DATE ! under “Select”) UPDATE Follow the steps below to change “Voice Set”: Step 1: Short press “rotate switch” to open “system set”; Step 2: Use “rotate switch” to choose the position you want to change; Step 3: Short press “rotate switch” to change the settings. 3.4 UPDATE Screen: BACK BACK Step 8: Wait for flashing; FrSky FSD could upgrade FrSky S.Port products (including modules, receivers, sensors and other S.Port enabled devices). Follow the steps below to finish the upgrade. Step 1: Create a new folder named “S.PORT” in the TF card by PC; Step 2: Download the firmware from FrSky website and put the frk. firmware into the “S.PORT” folder; Step 3: Insert the TF card back into the FSD card slot; Step 4: Connect the battery to the FSD by the Y harness, and use rotate switch to choose UPDATE on the main screen and short press to enter UPDATE screen; VA RIO 2 .fr k De vi ce fo u n d ! Wa i t fo r fl a sh i n g ... UPDATE BACK “Y” Cable VA R I O 2 . f r k D e vi ce f o u n d ! Firmware is updated s.port UP DAT E Step 9: After the firmware is updated, choose and short press BACK to go back to the update screen. B A CK VA RIO 2 .fr k De vi ce fo u n d ! Fi r mwa r e i s u p d a te d LED Variometer Sensor UPDATE PORT BACK Battery Step 5: Use rotate switch to choose the frk. firmware you want to upgrade and short press to open; 3.5 DATA Screen: 00 : 03 : 39 To U p d a te d F i l e s SWR FLVSS.frk VARIO2.frk FrSky Electronic Co., Ltd E-mail:[email protected] P1 0 RBat 0.0 A1 0.0 A2 0.0 A3 0.0 Time: H/M/S (If GPS sensor is connected, the time will be GTM in 10 seconds; if not, the time will be your operation time) TF: If the FSD has the TF card inserted already, here will have the TF logo; if not, here will show ER (error). Short press “rotate switch” will activate the TF to be “ON”, meanwhile start to log your telemetry data. P: Number of pages Step 6: Connect the right device to FrSky FSD by the Y harness; Website:www.frsky-rc.com TF 0 RSSI Technical Support: [email protected] Website:www.frsky-rc.com FrSky Electronic Co., Ltd E-mail: [email protected] Technical Support: [email protected] www.frsky-rc.com www.frsky-rc.com Follow the steps below to change the data names from page 1 to page 3: Step 1: Short press the rotate switch Step 2: Use the rotate switch to choose the position you want to change Step 3: Short press the rotate switch Step 4: Use the rotate switch and find the data name you want and short press rotate switch to confirm. PhyID 01 NewPyID 01 SEND GNum 01 NewGNum 01 RESET Tip: Finished Note: Data screen has 5 pages in total. Just enable the GPS sensor and Lipo Voltage Sensor on the SYSTEM screen to enable the page 4 and 5. Page 4: GPS data Latitu: Latitude (unit: degree) Longi: Longitude (unit: degree) Distance: Distance from your first position to your flight position now Date: Y/M/D 00 : 03 : 43 Page 5: Lipo Voltage Sensor data Total: Total voltage, cell number and cell voltage of all the batteries connected. P4 L a ti tu : 0 .0 000 Longi: D i sta n ce : 0 .0 000 0 D a te : 2 0 0 0 -0 0 -00 To ta l : 0 .0 0 0 .0 0 0 .0 0 0 .0 0 0 .0 0 0 .0 0 0 .0 0 0 .0 0 0 .0 0 0 .0 0 0 .0 0 0 .0 0 0 .0 0 0s P5 PhyID physical ID of the sensor NewPyID new physical ID you want to set for the sensor SEND RESET Tip GNum group number of the sensor NewGNum new group number you want to set for the sensor send your settings to the sensor reset your settings to default the result of your settings Follow the steps below to set “PhyID” and “GNum” for S.Port Sensors: Step 1: Use “rotate switch” to choose “IDSET”; Step 2: Use rotate switch to choose New PyID and/or New GNum and short press; Step 3: Set the number for the sensor and short press “rotate switch”; Step 4: Short press “SEND” and confirm “Tip” indicates “Finished”. 3.7 INFO Screen: Data SWR RSSI RBat A1 A2 A3 A4 A3_1 A4_1 Valt Vspd Vcu1 Vcu2 Vcu3 Vcu4 CUR1 CUR2 CUR3 CUR4 TEM1 TEM2 RPM1 RPM2 RPM3 RPM4 Fuel Altg Spdg CC1 CC2 CC3 CC4 PWR1 PWR2 PWR3 PWR4 Cors Scur Vol- Meaning Antenna Detection Received Signal Strength Indicator Receiver Battery Voltage Analog Voltage (Receiver) Analog Voltage (S.port to UART Host) Analog voltage (S.port to UART Remote) Altitude of Variometer Sensor Vertical Speed Voltage of Current Sensor Current of Current Sensor Temperature RPM Fuel Level Altitude of GPS Speed of GPS Current Consumption Power of Current Sensor Direction of GPS Sum Current of Current Sensor the Lowest Voltage among all Cells FrSky Sport Dashboard Firmware Vers: v1.52 Eeprom Vers: v0.3 Fr S ky S p o r t Da sh b o a r d Fi r mwa r e Ve r s: v1 .5 2 E e p r o m Ve r s: v0 .3 4. Upgrade FSD Follow the steps below to upgrade the FSD firmware: Step 1: Create a new folder named “Firmware” in the TF card by PC. Step 2: Download the firmware from FrSky website and put the .bin file into the “Firmware” folder. Step 3: Insert the TF card back into the FSD card slot. Step 4: Hold “Page” button while power on the FSD. Step 5: Use “rotate switch” to choose “YES” to reflash (or “NO” to quit) and short press “rotate switch” to confirm the upgrade. FrSky Sport Dashboard Boot Mode Ver-0.4 Yes to Reflash or NO to quit? YES NO Ready to upgrade TIPS: Vcu, CUR, TEM1, RPM, CC, PWR have several data because of the different groups. 3.6 IDSET Screen: Website:www.frsky-rc.com FrSky Electronic Co., Ltd E-mail:[email protected] Technical Support: [email protected] Website:www.frsky-rc.com FrSky Electronic Co., Ltd E-mail: [email protected] Technical Support: [email protected]