Transcript
1
2
3
4
DO NOT SCALE A
B
SEE PAGE 2 FOR INSTRUCTION SHEET. PRINTING INSTRUCTIONS:PRINT INSTRUCTION SHEET ON A4 SIZE STANDARD WEIGHT PAPER.
C
CUT IN HALF TO PRODUCE TWO A5 INSTRUCTION SHEETS.
D
FILE LOCATION- S:/USER INSTRUCTIONS/6450/6450104600EB-H.DOC Finish
Dims not in tol.
.
.
Scale
NTS .
.
.
. .
. .
. .
.
.
. .
. .
. .
.
.
. .
. .
. .
H
3 31
RN 12-9-11
RJT 13-9-11
WD 13-9-11
G
20
0 99
9
KAP 28-2-07
KN 28-2-07
BLN 28-2-07
49
LJP 12-1-06
RJT 14-4-06
BLN 28-4-06
Checked
Approved
20
20
6
40
6
48
Iss
MCO
Drawn Date
FORM E54 ISSUE:9 10.03.11
Date
ADC Communications (Australia) Pty Ltd. reserve all rights for this technical document, including patent rights and copyright. C This document must not be reproduced or passed on to third parties without our agreement, and must not be misused by the recipient or by third parties in any other way. ADC Communications (Australia) Pty Ltd. shall demand damages for any infringment of these rights and there may be other legal consequences. Material:
Description:
A4 STANDARD
Projection
WEIGHT PAPER
INSTRUCTION SHEET FOR HIGHWAY PATCH PANEL
Dimensions in millimetres Sheet Project:
1of
.
Drawing No:
Date
PROENG FILE:
6450104600EB Article No.
Replacement for:
6450104600EB
01 H Code
Sht
6450104600EB.....01 G
Iss
2 HEREFORD ST BERKELEY VALE 2261 NSW AUSTRALIA PH: (02) 4389 5000 FAX: (02) 4388 4499
2
E
INSTALLATION INSTRUCTIONS FOR ADC KRONE ® HIGHWAY PATCH PANELS
INSTALLATION INSTRUCTIONS FOR ADC KRONE ® HIGHWAY PATCH PANELS
PRODUCT NUMBER: 6450 1 046-00, 6450 1 048-00 & 6450 1 049-00
PRODUCT NUMBER: 6450 1 046-00, 6450 1 048-00 & 6450 1 049-00
CONGRATULATIONS on your purchase of the new ADC KRONE highway patch panel. The
CONGRATULATIONS on your purchase of the new ADC KRONE highway patch panel. The
sleek modern design and higher performance characteristics will compliment any 19” equipment rack making it a feature of your cabling system.
sleek modern design and higher performance characteristics will compliment any 19” equipment rack making it a feature of your cabling system.
TO REMOVE END CAP
TO REMOVE END CAP
TO REMOVE END LENS
TO REMOVE END LENS
Lens may be removed from front using a knife blade (or similar) however, this may cause marking on the face of the end piece. The preferred method is to remove the end piece and pop out the lens by pushing through the hole provided on the rear of the end piece. The logo label may be reversed to provide an area for rack position.
TO REMOVE OUTLET LENS
TO REMOVE OUTLET
Lift end with screwdriver or similar and lift until clips disengage. To replace lens place RH end in first and press the clips into place.
WIRING INSTRUCTIONS
First, push at top of outlet with screwdriver blade to release top latches. Next, place screwdriver blade at bottom of outlet and tap firmly to release lower latches. DO NOT pull on rear of outlet as this may damage the outlet
Beginning with the outlet closest to cable entry point, e.g. L\H Insertion Tool or R/H entry. Prepare the cable by stripping approx 40mm of the sheath. Fan the wires into the termination slot identified by the colour coding on the jack. Its essential that the twist rate of 5mm min. and each pair be maintained as close as possible to the point of Bend wire upwards termination (max. 13mm untwist is allowed by current To ensure cut-off international standards). Commence with the blue pair followed by orange, brown and green pairs. Terminate the wires using an ADC KRONE termination tool.
PATCH CORD MINDER PANEL
Cutter Blade
When using jumper rings on the rear of the Patch Cord Minder Panel, terminate the wires on the outlets prior to fitting the jumper rings
Part No: 6450104600EB
Issue: H
Sheet 1 of 1
Lens may be removed from front using a knife blade (or similar) however, this may cause marking on the face of the end piece. The preferred method is to remove the end piece and pop out the lens by pushing through the hole provided on the rear of the end piece. The logo label may be reversed to provide an area for rack position.
TO REMOVE OUTLET LENS
TO REMOVE OUTLET
Lift end with screwdriver or similar and lift until clips disengage. To replace lens place RH end in first and press the clips into place.
WIRING INSTRUCTIONS
First, push at top of outlet with screwdriver blade to release top latches. Next, place screwdriver blade at bottom of outlet and tap firmly to release lower latches. DO NOT pull on rear of outlet as this may damage the outlet
Beginning with the outlet closest to cable entry point, e.g. L\H Insertion Tool or R/H entry. Prepare the cable by stripping approx 40mm of the sheath. Fan the wires into the termination slot identified by the colour coding on the jack. Its essential that the twist rate of 5mm min. and each pair be maintained as close as possible to the point of Bend wire upwards termination (max. 13mm untwist is allowed by current To ensure cut-off international standards). Commence with the blue pair followed by orange, brown and green pairs. Terminate the wires using an ADC KRONE termination tool.
PATCH CORD MINDER PANEL
Cutter Blade
When using jumper rings on the rear of the Patch Cord Minder Panel, terminate the wires on the outlets prior to fitting the jumper rings
Part No: 6450104600EB
Issue: H
Sheet 1 of 1