Installation Instructions
110-120V Salara/Hardwire by Draper Caution 1 Read instructions through completely before proceeding. 2 Follow instructions carefully. Installation contrary to instructions invalidates warranty.
3 Screen should be accessible for complete removal should fabric become damaged or should other service be required.
4 Screen should be installed level (using a carpenter’s level). 5 Nothing should be fastened to screen dowel or viewing surface. 6 Operating switch(es) packed separately in screen carton. Do not discard with packing material.
7 Screen operates on 110-120V, 60 hz., 1.1 amp current draw.
NOTE: Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment. These instructions are meant as a guide only. They do not imply any responsibility on the part of Draper, Inc. for improper installation or faulty workmanship at the jobsite.
Wall/Ceiling Flush Mounting
1 Attach Mounting Brackets to wall or ceiling (see Fig. 1). The installer should furnish screws, toggle bolts, molly bolts, nylon or lead anchors as required by the mounting surface. Installer also needs to ensure the mounting surface is reinforced sufficiently to support the screen. Brackets must be level with each other. Mounting Bracket
Ceiling Mounting Bracket
11/2"
Wall
11/2"
Figure 1 2 Attach the screen by snapping the extrusions on the back of the case onto the brackets. With the lower edge of the screen case tilted away from the wall, engage the rib on top of the case with the slot on each bracket. Slide the screen case along the brackets to adjust the screen location from left to right if necessary (see Fig. 2). Once the case is in position, pivot the case back toward the brackets until the lower edge of the case "snaps" into place with the spring-loaded latch (see Fig. 3).
US Patent Pending.
26 seconds/Off 3 minutes. Screen shipped with internal wiring complete. Junction box is located inside left endcap and cover plate is secured to endcap with one screw. Junction box contains red, black and white pigtail leads and green internal ground wire, per wiring diagram on reverse. Screen is shipped with internal wiring complete and control switch(es) fully boxed. Wire connecting screen to switch(es) and switch(es) to power supply should be furnished by installer. Connections should be made in accordance with attached wiring diagram, and wiring should comply with National and local electrical codes. When connections are complete, test screen operation. The switch cover plate is not labeled "Up" and "Down." If screen operates in the opposite direction of the switch button (i.e. pressing switch up makes the screen go down), no re-wiring is necessary; simply flip the switch 180 degrees. All operating switches should be “OFF” before power is connected.
Operation
Screen is equipped with a handheld remote or 3-position operating switch (see below). Three positions (up-off-down) permit operation to be stopped at any point. Factory adjusted limit switches automatically stop screen when fully down or fully up.
Wiring/Control Options:
Salara/Hardwire—Provided with 3-position wall switch for 110-120V AC. Controls for 110-120V AC hardwired Salara: 110-120V Single Station Control — 3-position up-off-down switch permits operation to be stopped at any point. Factory adjusted limit switches automatically stop screen when fully down or fully up. 110-120V Multiple Station Control—Switches are similar in appearance to 110V Single Station Control. Screen stops when switch is released and may be restarted in either direction. Factory adjusted limit switches stop screen automatically when fully down or fully up. 24V Control — Three-button up-stop-down switches stop at any point desired, operate in any sequence. Factory adjusted limit switches automatically stop screen when fully down or fully up. Key Operated Switching — Two kinds of key-operated switches are optionally available with this unit. 1 The key-operated power supply switch controls power to the screen and switches. When it is “off ”, the switches will not operate screen. Key may be removed from the switch in either “on” or “off” position. 2 A three-position key switch permits the screen to be operated directly by key. In this case, the screen’s operator must always have a key. RS232/Ethernet—Serial communication and network communication optionally available with wall switches, RF or IR remote. Salara/Hardwire with Built-in IR—Provided with handheld infrared remote transmitter.
Adjustments
Please Note: Screen limits are factory set for optimum performance of the screen. A procedure is outlined below for minor tweaks, but any adjustment of these limits may negatively affect the flatness of the screen surface and could also void the warranty. Please check with Draper prior to resetting screen limits. CAUTION: Always be prepared to shut screen off manually when new adjustment is being tested. Screen may be severely damaged if viewing surface is allowed to run too far up or too far down. CAUTION: Be sure all switches are in “off” position before adjusting limit switches.
Extrusions along back of case
Figure 2
Standard or IR Hardwired Salara
1
2 Figure 3
3
Electrical Connections
Screen operates on 110-120V AC, 1.1 amp current draw. Duty cycle: On
Copyright ©2015 Draper Inc. Form Salara-HW_Inst15
Printed in U.S.A.
There are two holes in the left end cap (as seen from audience) for both limit switch adjustments and neither is labled. The hole closest to the audience is the up limit and the hole furthest from the audience is the down limit “Down” limit switch: Down stopping position can be adjusted by turning knob furthest from audience with a screw driver or hex wrench. Turning knob counterclockwise will allow viewing surface to run farther down. Turning it clockwise will reduce the amount of exposed viewing surface. “Up” limit switch: You should never have to adjust this limit! If you do, however, the Up stopping position can be adjusted by turning knob closest to audience with a screw driver or hex wrench through the small grommet. Turning knob counterclockwise will allow surface to run farther into the screen case. Turning it clockwise will allow viewing surface to stop farther out of the screen case. Dimensional drawings on page 2 If you encounter any difficulty installing or servicing your Salara, call your dealer or Draper, Inc., Spiceland, Indiana, (765) 987-7999 or fax (765) 987-7142.
Salara/Hardwire 110-120V Instructions by Draper
Page 2 of 2
Caution: Do not remove the roller assembly from the case unless necessary for repairs. If the roller assembly is removed, be sure motor is fully re-seated in the bracket, and re-secure it carefully with the motor retaining spring (see diagram at right). Dimensions Floating Mounting Brackets 5/16"
Case Length
31/8"
13/8" 37/16"
313/16" 51/16"
3/8"
311/16"
Viewing Surface
5/16"
57/16"
Blue
Location of key operated on-off switch if furnished
Black
Cap off with wire nut and tape
Red
(1) #10 Ring Terminal on each ground wire
Motor
Red Dashed wiring by electrician
Black Blue
Green
Green/Yellow Black White
White
Green/Yellow Green
Control Single gang box by others switch Min. 4" x 2 1/8" x 1 7/8" deep Red Blue Black
Red
Motor
Screw attaching endcap to case
Black
Green
Green/Yellow
Chassis ground label next to screw
White
Dashed Wiring By Others
Red
Black Blue
To 110-120V Line
RS232 Data from Control System RS232 Data to Control System Signal Ground & Manual Switch Common Manual Down Switch Manual Up Switch
Green
Red
Please Note: Do not wire motors in parallel.
Multiple Station Control
L N Neu Dir Dir
Screw attaching endcap to case
Black
Motor
White
110-120V Salara/Hardwire with Built-in IR
AC In Motor
Chassis ground label
Please Note: Do not wire motors in parallel. Single Station Control
Chassis ground label
Wiring Diagrams Standard 110-120V Salara/Hardwire
Red
Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep. 3 shown. More or less equally Location of key feasible. operated on-off switch if furnished Black
Dashed wiring by others
To 110-120V Line
Chassis ground label Screw attaching endcap to case Green/Yellow Internal Screen Wiring White (Common) Red (Up) Black (Down) Green/Yellow (Motor Ground)
N To 110-120 VAC L1 Line GND
Low Voltage & Wireless Control Receiver Button
White or Blue-Common to screen & 110 VAC Neutral Red-to screen (directional) Brown-to screen (directional) Yellow-to 110 VAC-Hot Black-to 110 VAC-Hot Green/Yellow (Ground)
Electrically Straight Data Cable to more LVC-IV modules* RS232/485 Inputs/Outputs Wall Switch Low Voltage Trigger 3-28 VAC *A maximum of six (6) IR Eye Input LVC-IV modules can be linked together.
Location of key operated 0n-off switch if furnished. Dashed wiring by electrician Low voltage wiring by others
www.draperinc.com
3 Button Wall Switch DOWN - Black COM - White UP - Red
(765) 987-7999