Preview only show first 10 pages with watermark. For full document please download

Instructions

   EMBED


Share

Transcript

DIF-110 POWER SUPPLY 60 WATTS PS-60W POWER SUPPLY 21 WATTS PS-21W 12" UNDERCABINET 8’ CABLE, EXT • CX-8 45" UNDERCABINET (INCLUDED W/ UC) EXTENSION CABLE [DL or UC] POWER CABLE, SW 22" UNDERCABINET 6" CABLE, SPLITTER • CY-6 RARE EARTH SUPER-MAGNETS PATCH CABLE UNDERCABINET SPLITTER CABLE [DL or UC] ( FOR 21W / 60W PS ONLY) OCCUPANCY SENSOR 12’ CABLE, POWER N/SW, UC • CPN-12 SPLITTER CABLE MOUNTING PLATE MP-S POWER CABLE, SW POWER CABLES [UC only] POWER SUPPLY 8 WATTS PS-8W 5" BASE WBC-S 28" CABLE, PATCH, UC • CP-28 14" CABLE, PATCH, UC • CP-14 CLAMP CL-S PATCH CABLES [UC only] POWER SUPPLIES DESK LAMP WEIGHTED BASES MOUNTING OPTIONS Finelite, Inc. warranties all Personal Lighting System components to be free from defects in materials and workmanship for a period of three years. Contact Finelite Inside Sales for return information if you have a warranty claim. DL-C INSTRUCTIONS WARRANTY AND RETURN INFORMATION PLS SY ST E M 6" CABLE, PATCH, UC • CP-6 3" CABLE, PATCH, UC • CP-3 PLS USE & CARE P L S L I G H T I N G F A C T S CM L A B E L S DESK LAMP TROUBLESHOOTING GUIDELINES What if the fixtures (Desk Lamps and Undercabinet) don't illuminate? • Check all connections. Is the connection to the supply voltage secure and fully inserted? • Is the power indicator LED illuminated? (21W and 60W power supplies only) — If the LED is not illuminated, contact Finelite. • Is the power supply “OCC SENSOR” switch in the “NO” position? • Are all low voltage connections secured and fully inserted? • Are all on/off fixture switches switched to “ON”? • Check to see that you have not exceeded a total of the maximum rated load of the power supply - disconnect fixtures until you are below maximum rated load. What if the fixtures “flash” when powered? • Check to see that you have not exceeded a total of the maximum rated load of the power supply - disconnect fixtures until you are below maximum rated load. • Cycle power on/off to power supply if necessary. What if the Occupancy Sensor does not turn off system? What if the Occupancy Sensor turns the system off while seated at a station? • Make sure the occupancy sensor is set to a delay setting between min and max (10-15 minutes works best for most installations). • Make sure that the sensor window is not obstructed and facing towards your most common seated location. • For best results mount the occupancy sensor underneath your desk. CARE AND CLEANING OF THE PLS SYSTEM Your PLS system should operate trouble free for the life of the system. You may periodically wipe the system clean with a slightly damp soft cloth. Do not use any solvent or alcohol based cleaning products on plastic or painted surfaces or on the labels. Finelite, Inc. • 30500 Whipple Rd • Union City, CA 94587-1530 510-441-1100 • Fax 510-441-1510 • www.finelite.com UNDERCABINET - 12", 22", & 45" © 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98384. 04/17 • Is the “OCC SENSOR” switch in the “YES” position? • Is the occupancy sensor connected to the power supply? • Does the indicator light on the occupancy sensor illuminate? (Note: It will only illuminate when sensing movement.) • Try turning the delay to a value between 30 minutes (max) and 30 seconds (min) on back of sensor (~10-15 minutes works best for most installations). • Consult occupancy sensor instruction sheet (supplied with sensor) for more information. PERSONAL LIGHTING SYSTEM Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful Interference in which case the user will be required to correct the interference at his own expense. P L S I N ST R U CT I O N S DESK LAMP UNDERCABINET Wood Steel MOUNTING Rare earth super-magnets provided pre-installed for mounting directly on steel. NOTE: Remove rare earth magnets when installing with wood screws. Contact factory. POWER SUPPLIES Front 1” - 2.5” OCC SENSOR OCC SENSOR No Yes Back Drill 1.125 in. dia. (29mm) 1” - 2.5” Occupancy Sensor max Time Delay min FOR MORE INFO, SEE PLS OCCUPANCY SENSOR INSTRUCTION SHEET