Transcript
Integrating Sphere Test Report Relevant Standards IES LM-79-2008 ANSI C78.377-2011, ANSI C82.77-2002 CIE 13.3-1995, CIE 15-2004
Prepared For
Elemental LED Inc, DBA Diode LED Wes Buck Suite 211,1195 Park Ave. Emeryville, CA 94608 United States
Catalog Number
BLAZE™ 12v LED Tape Light DI-12V-BL27-80XX Order Number
10460077 Test Number
758917 Test Date 2015-01-21 Prepared By
Approved By
Javier Caban, Technician
Eric Gaudreau, Engineering Project Handler
The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories.
Test Number 758917 - Page 1 of 4
Luminaire Description: Catalog Number: Lamp: Mounting: Ballast/Driver:
LED strip BLAZE™ 12v LED Tape Light DI-12V-BL27-80XX 36 white LEDs Surface One Meanwell LPV-60-12
Luminaire
Summary of Results Radiant Flux: Luminous Flux: Luminaire Efficacy: CCT: CRI (Ra): Chromaticity (x): Chromaticity (y): Chromaticity (u): Chromaticity (v): Duv:
896.4 mW 267.8 Lumens 83.7 Lumens/Watt 2598 K 82.8 0.4635 0.4041 0.2678 0.3503 -0.0028
Test Conditions Test Temperature: Voltage: Current: Power:
25.1 12.00 0.2660 3.200
°C VDC A W
Testing was performed in a 2-meter integrating sphere using the 4π geometry method. Absorption correction was employed for this measurement. Test Number 758917 - Page 2 of 4
Chromaticity Coordinates x 0.4635
y 0.4041
u 0.2678
v 0.3503
u' 0.2678
v' 0.5254
Duv -0.0028
Color Rendering Index Detail Ra (CRI) 82.8
R1 81.2
R2 90.6
R3 96.5
R4 79.4
R5 80.5
R6 87.6
R7 83.6
R8 63.0
R9 21.7
R10 78.1
R11 77.1
R12 72.9
R13 83.0
R14 98.3
Flux vs Wavelength
7.00
Spectral Flux (mW/nm)
6.00 5.00 4.00 3.00 2.00 1.00 0.00 350
400
450
500
550
600
650
Wavelength (nm)
Test Number 758917 - Page 3 of 4
700
750
800
850
Spectral Power Distribution λ(nm) 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421
mW/nm 0.0251 0.0386 0.0399 0.0316 0.0174 0.0317 0.0261 0.0295 0.0277 0.0317 0.0239 0.0224 0.0254 0.0261 0.0226 0.0252 0.0222 0.0230 0.0224 0.0227 0.0250 0.0251 0.0261 0.0298 0.0263 0.0271 0.0262 0.0320 0.0243 0.0198 0.0236 0.0216 0.0211 0.0236 0.0254 0.0252 0.0238 0.0194 0.0251 0.0208 0.0226 0.0278 0.0226 0.0281 0.0285 0.0266 0.0225 0.0231 0.0262 0.0225 0.0251 0.0274 0.0306 0.0307 0.0303 0.0334 0.0333 0.0354 0.0370 0.0412 0.0469 0.0480 0.0563 0.0621 0.0661 0.0740 0.0812 0.0973 0.103 0.121 0.135 0.154
λ(nm) 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493
mW/nm 0.172 0.192 0.217 0.240 0.271 0.306 0.342 0.384 0.429 0.481 0.527 0.587 0.661 0.740 0.823 0.929 1.04 1.18 1.34 1.53 1.70 1.89 2.08 2.26 2.42 2.51 2.57 2.56 2.52 2.40 2.26 2.11 1.95 1.80 1.66 1.55 1.46 1.40 1.35 1.30 1.25 1.21 1.17 1.12 1.06 1.01 0.952 0.902 0.851 0.812 0.774 0.752 0.732 0.716 0.714 0.713 0.716 0.718 0.726 0.731 0.744 0.751 0.769 0.787 0.808 0.824 0.854 0.882 0.911 0.950 0.989 1.02
λ(nm) 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565
mW/nm 1.07 1.11 1.15 1.20 1.24 1.28 1.32 1.36 1.40 1.45 1.49 1.53 1.57 1.61 1.65 1.69 1.72 1.78 1.80 1.84 1.88 1.92 1.95 1.99 2.02 2.06 2.09 2.12 2.16 2.19 2.22 2.25 2.29 2.33 2.36 2.39 2.43 2.46 2.49 2.53 2.57 2.60 2.65 2.68 2.72 2.76 2.81 2.84 2.89 2.92 2.98 3.01 3.06 3.12 3.15 3.20 3.24 3.29 3.34 3.40 3.44 3.49 3.55 3.59 3.65 3.71 3.74 3.81 3.86 3.92 3.98 4.02
λ(nm) 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637
mW/nm 4.09 4.14 4.20 4.26 4.30 4.36 4.42 4.47 4.52 4.57 4.62 4.68 4.73 4.79 4.85 4.89 4.94 4.97 5.01 5.08 5.12 5.15 5.21 5.23 5.30 5.31 5.36 5.40 5.42 5.47 5.50 5.53 5.55 5.59 5.62 5.64 5.66 5.68 5.69 5.71 5.73 5.74 5.74 5.76 5.76 5.77 5.77 5.77 5.77 5.76 5.76 5.75 5.72 5.73 5.71 5.68 5.67 5.64 5.63 5.60 5.57 5.55 5.52 5.49 5.46 5.41 5.37 5.35 5.29 5.26 5.21 5.15
Test Number 758917 - Page 4 of 4
λ(nm) 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709
mW/nm 5.10 5.07 5.01 4.95 4.90 4.86 4.80 4.74 4.69 4.62 4.57 4.51 4.44 4.36 4.31 4.25 4.19 4.12 4.06 3.99 3.93 3.86 3.81 3.73 3.67 3.60 3.54 3.47 3.40 3.34 3.27 3.21 3.14 3.08 3.01 2.95 2.89 2.84 2.77 2.71 2.65 2.59 2.54 2.48 2.42 2.37 2.31 2.26 2.20 2.15 2.09 2.05 1.99 1.94 1.90 1.85 1.80 1.76 1.71 1.66 1.62 1.58 1.54 1.50 1.46 1.42 1.38 1.34 1.31 1.27 1.24 1.21
λ(nm) 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781
mW/nm 1.17 1.14 1.11 1.07 1.04 1.02 0.989 0.956 0.930 0.902 0.880 0.854 0.830 0.800 0.778 0.759 0.737 0.713 0.692 0.674 0.654 0.635 0.613 0.595 0.579 0.562 0.546 0.522 0.512 0.495 0.480 0.461 0.447 0.434 0.422 0.411 0.396 0.386 0.374 0.360 0.350 0.341 0.332 0.319 0.310 0.300 0.290 0.282 0.273 0.266 0.258 0.250 0.244 0.233 0.226 0.220 0.214 0.206 0.198 0.195 0.188 0.180 0.175 0.169 0.165 0.160 0.155 0.151 0.147 0.141 0.137 0.132
λ(nm) 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850
mW/nm 0.128 0.125 0.121 0.119 0.116 0.108 0.104 0.102 0.0994 0.0988 0.0946 0.0923 0.0894 0.0864 0.0845 0.0797 0.0768 0.0761 0.0730 0.0708 0.0689 0.0674 0.0637 0.0625 0.0617 0.0594 0.0590 0.0558 0.0532 0.0526 0.0517 0.0488 0.0480 0.0472 0.0453 0.0447 0.0428 0.0409 0.0406 0.0397 0.0382 0.0382 0.0382 0.0344 0.0350 0.0321 0.0307 0.0321 0.0315 0.0294 0.0293 0.0276 0.0270 0.0256 0.0242 0.0236 0.0234 0.0246 0.0255 0.0235 0.0223 0.0207 0.0201 0.0202 0.0188 0.0195 0.0201 0.0198 0.0180
Photometric Indoor Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002
Prepared For
Elemental LED Inc, DBA Diode LED Wes Buck Suite 211,1195 Park Ave. Emeryville, CA 94608 United States
Catalog Number
BLAZE™ 12v LED Tape Light DI-12V-BL27-80XX Project Number
10460077 Test Number
758916
Test Date 2015-01-21 Prepared By
Approved By
Javier Caban, Technician
Eric Gaudreau, Engineering Project Handler
The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories.
Test Number 758916 - Page 1 of 5
Luminaire Description: Catalog Number: Lamp: Mounting: Ballast/Driver:
LED strip BLAZE™ 12v LED Tape Light DI-12V-BL27-80XX 36 white LEDs Surface One Meanwell LPV-60-12
Luminaire
Test Conditions Test Temperature: Voltage: Current: Power:
25.0 12.00 0.2705 3.248
°C VDC A W
Test Number 758916 - Page 2 of 5
INTENSITY(CANDLEPOWER) SUMMARY
180
ANGLE ALONG 0 96 5 93 120 10 92 15 90 20 87 25 84 30 79 35 74 90 40 69 45 63 50 56 55 48 60 41 65 33 70 24 75 16 60 80 9 85 3 90 0
150
ACROSS 45 ALONG
30
60
22.5 96 95 94 92 90 86 82 77 71 65 58 50 42 34 25 17 9 3 0
45 96 96 95 93 90 87 82 77 71 65 58 50 42 34 25 17 9 3 0
67.5 ACROSS 96 96 96 96 95 95 93 93 90 90 86 86 82 82 77 77 71 71 65 65 58 58 50 50 42 42 34 34 25 25 17 17 9 9 3 3 0 0
OUTPUT LUMENS 9 26 40 48 50 45 33 18 4
ZONAL LUMENS AND PERCENTAGES ZONE 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180
90
0
30
LUMENS 75 123 217 272 149 55 0 272
% LUMINAIRE 27.52 45.12 79.83 100.00 54.88 20.17 0.00 100.00
EFFICACY (LUMENS PER WATT):
84.9
*** THIS IS AN ABSOLUTE TEST *** LUMINOUS LENGTH: 12.000 INS WIDTH: 0.375 INS
LUMINANCE SUMMARY CD./SQ.M. ANGLE 45 55 65 75 85
ALONG 30469 29095 26651 21493 9880
45 31759 30351 27726 22384 11490
SC(ALONG):
S/MH: 1.2, SC(ACROSS):
ACROSS 31587 30231 27694 22443 11703
TESTED IN ACCORDANCE WITH IES PROCEDURES. Test Number 758916 - Page 3 of 5
1.3 1.3
INTENSITY(CANDLEPOWER) DATA IN 2.5 DEGREE STEPS ANGLE
0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 37.5 40.0 42.5 45.0 47.5 50.0 52.5 55.0 57.5 60.0 62.5 65.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0
ALONG 96 93 93 92 92 91 90 88 87 85 84 81 79 77 74 72 69 66 63 59 56 52 48 45 41 37 33 29 24 20 16 12 9 5 3 0 0
22.5 96 96 95 95 94 93 92 91 90 88 86 84 82 79 77 74 71 68 65 61 58 54 50 46 42 38 34 30 25 21 17 13 9 6 3 1 0
PLANE 67.5
45 96 97 96 96 95 94 93 92 90 89 87 85 82 80 77 74 71 68 65 62 58 54 50 46 42 38 34 30 25 21 17 13 9 6 3 1 0
96 96 96 95 95 94 93 91 90 88 86 84 82 79 77 74 71 68 65 61 58 54 50 46 42 38 34 30 25 21 17 13 9 6 3 1 0
ACROSS 96 96 96 95 95 94 93 91 90 88 86 84 82 79 77 74 71 68 65 61 58 54 50 46 42 38 34 30 25 21 17 13 9 6 3 1 0
Test Number 758916 - Page 4 of 5
AVERAGE 96 96 95 95 94 93 92 91 90 88 86 84 82 79 77 74 71 68 64 61 58 54 50 46 42 38 34 29 25 21 17 13 9 6 3 1 0
OUTPUT LUMENS
9
26
40
48
50
45
33
18
4
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE = .20 CC WALL
90 70
50
80 30
10
70
50
70 30
10
70
50
50 30
10
50
30
30 10
50
30
10 10
50
30
0 10
0
RCR 0 1.221.221.221.22 1.191.191.191.19 1.161.161.161.16 1.111.111.11 1.061.061.06 1.021.021.02 1.00 1 1.131.081.041.00 1.101.061.020.98 1.071.041.000.97 0.990.960.94 0.950.930.91 0.920.900.88 0.86 2 1.030.960.890.83 1.010.940.870.82 0.990.920.860.81 0.880.830.79 0.850.810.77 0.820.790.76 0.74 3 0.950.840.760.70 0.920.830.750.69 0.900.810.740.69 0.780.720.67 0.760.710.66 0.730.690.65 0.63 4 0.870.750.660.60 0.850.740.660.60 0.830.730.650.59 0.700.640.58 0.680.620.58 0.660.610.57 0.55 5 0.810.670.580.52 0.780.660.580.51 0.760.650.570.51 0.630.560.51 0.610.550.50 0.590.540.49 0.47 6 0.740.600.510.45 0.720.590.510.45 0.700.580.500.44 0.560.490.44 0.550.480.44 0.530.480.43 0.41 7 0.680.540.450.39 0.660.530.450.39 0.650.520.440.38 0.510.430.38 0.490.430.38 0.480.420.37 0.35 8 0.630.490.400.34 0.610.480.400.34 0.600.470.390.34 0.460.390.34 0.450.380.33 0.440.380.33 0.31 9 0.580.440.360.30 0.570.440.350.30 0.550.430.350.30 0.420.350.30 0.410.340.29 0.400.340.29 0.27 10 0.540.400.320.27 0.530.400.320.26 0.520.390.320.26 0.380.310.26 0.370.310.26 0.360.300.26 0.24
THE ABOVE COEFFICIENTS HAVE BEEN CALCULATED BASED ON LUMINAIRE LUMENS BECAUSE IN AN ABSOLUTE TEST THE BARE LAMP LUMENS ARE UNKNOWN. LIGHTING DESIGN CALCULATIONS MADE USING THESE COEFFICIENTS SHOULD THEREFORE USE THE LUMINAIRE LUMENS IN THE CALCULATION FORMULA
LABORATORY RESULTS MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST AND FIELD FACTORS HAVE NOT BEEN APPLIED. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
Test Number 758916 - Page 5 of 5