Preview only show first 10 pages with watermark. For full document please download

Intelligent Optical Smoke Detector I-9102

   EMBED


Share

Transcript

E-MAIL: [email protected] HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU E-MAIL: [email protected] HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Digital Optical Smoke DI-9102 Detector Secure and speedy communication through the on board processor enables the detector to make its own decision and sending data to the panel within a second, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. Features and Benefits 1. 2. 3. Advance digital sensing technique Built in 8 bit microprocessor Algorithm maps for faster response and false alarm rejection 4. Secure and speedy communication 5. Intelligent Drift compensation 6. Self diagnosis and history log 7. Electronic addressing 8. Duplicated address report 9. Sensing chamber for exceptional dust proof ability and LED for 360º vision 10. Built in remote indicator output 11. Unique Low profile design 12. EN54 compliance Drift compensation, to monitor for the long term changes caused by aging, humidity, temperature, dust, etc. constant monitoring and self adjusting, the DI-9102 updates sensitivity base line for its sensing element. Even when the detector raises a warning advising that it requires cleaning, the sensitivity remains the same as the day it was installed. Electronic addressing and sensitivity adjustment can be done through Handhold Programming device (P-9910B), purchased separately and can be modified in the panel Technical Specifications Description • The DI-9102 Digital Optical Smoke Detector is the ideal device for most application due to its excellent digital response to a wide variety of different type of smoke patterns. The unit meets the sensitivity requirement of EN 54 part 7, European Standard Unique and pleasing with a low profile design, unobtrusive to complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, Digital signaling, Drift compensation, Self Diagnosis and history log. The integral microprocessor analyses the signal according to integrated algorithm of analyzing fire, then confirms these pattern with the preprogrammed fire scenarios and smoke patterns for a faster and safer response. By intelligent analysis, the smoke detection sensitivity will be automatically adjusted according to temperature change, providing a rapid response. E-MAIL: [email protected] • • • HTTP://GSTRU.RU • • • • • • • • • • Standard: EN54-part7 Protection rating: IP 32 Operating voltage: 24Vdc Loop voltage Operating Current: Standby current 0.6mA Alarm Current 1.8mA Operating temperature: -10°C to +50°C Relative humidity: 95% Application: Indoor use Detecting range: 100 sqm elevated than 6m, 80 sqm less than 6m Field Programmable sensitivity: 0.10dB/m to 0.56dB/m – 3 levels Address setting: Electronic addressing within 1 to 241, engage one address Visual Indicator: LED, Red ( lit steady when alarm, flash in polling) Material and colour: ABS, traffic-white Wiring: 1 pair non polarized Dimensions: diameter 10cm; height 4.45cm HTTP://WWW.HOMBI.RU Digital Optical Smoke DI-9102 Detector Mounting Standard Base The digital detector should be installed in compliance with all local codes or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Codes, BS 5389 and EN54. The detector is mounted using our standard base DB-01 allows easy adjustment. Suitable for surface mount only, mount on standard 1gang electrical back box with a mounting hole of 45mm to 75mm spacing. Detector Installation Before installation verify the proper wiring and base are firmly mounted to prevent detector damage before the installation. Point the detector in the base by the mark-line and secure the detector in that position by rotating it clockwise until it reaches the next mark line. MARK 1 DETECTOR BASE Electrical Box 60 Conduit MARK 1 MARK 2 DETECTOR Base 78mm Detector 100m m 75 Programming The address and sensitivity of the detector can be programmed using GST handheld programmer (P-9910), purchased separately. Connect the two wires of the handheld programmer to any two opposite terminals of the detector. 60 45 DETECTOR TERMINAL Wiring and Connection Connect the wires to the required terminal according to the wiring diagram. Detector loop are connected on terminals 1 and 3 while for the remote indicator output, connect the wire on terminals 2 and4.The cable must be fire rated type and the size depends on the wiring distance. Minimum size gauge 1.0mm²(18 AWG). Selection of compatible Control Panels Compatible with all GST Intelligent Fire Alarm Panels GST 100, GST 200, GST 5000, GST 9000. Ordering Information: Part No DI-9102 1 2 DB-01 60 Description Weight /Kg Digital Optical Smoke Detector with Remote Indicator Detector Base 0.110 Pack Qty per Box 120 0.049 360 MANUFACTURED IN ACCORDANCE WITH 3 4 E-MAIL: [email protected] FIELD DEVICE PROGRAMMER REMOTE INDICATOR Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Digital Intelligent Dual Heat Detector DI-9103 Meets the sensitivity requirement of EN 54 part 5 and part 6 European Standard Unique pleasing with a low profile design, unobtrusive to complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, Digital signaling, Drift compensation, Self Diagnosis and history log. Secure and speedy communication through the on board processor enables the detector to make its own decision and sending data to the panel within a second, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. Features and Benefits Dual fixed temperature heat detector. Combining both fixed temperature and rate of rise heat detection in a single sensor. As standard the fixed temperature is set to 66ºC while the rate of rise is set to 6ºC in one minute. The rate of rise function can be switched off and the fixed temperature can be adjusted between 54 and 74 degrees C 1. Built in 8 bit microprocessor 2. Algorithm maps for false alarm rejection 3. Digital sensing 4. Secure and speedy communication 5. Drift compensation 6. Self diagnosis and history log 7. Electronic addressing 8. Duplicated address report 9. LED for 360º vision 10. Built in remote indicator output 11. Unique low profile design 12. Fixed temperature response is adjustable via hand held programming tools. 13. EN54 compliance Electronic addressing and sensitivity adjustments can be done through Handhold Programming device (P-9910), purchased separately, and can be modified in the panel. Technical Specifications • • • • • • • • • • • Description • This detector is extremely reliable for application in places where may have high dust levels or smokey environments, making a normal smoke detector unsuitable , for example boiler/plant room, cars parks, kitchen, loading bays, furnace/kiln rooms. • • E-MAIL: [email protected] HTTP://GSTRU.RU Standard: EN54-part5 Protection rating: IP 22 Operating voltage: 24Vdc Loop voltage Operating Current: Standby Current 0.8mA Alarm Current 1.4mA Operating temperature: -10°C to +50°C Sensitivity: 3 levels; I=58°C, II=66°C, III=72°C Address setting: Electronic addressing within 1-241, engage one address Relative humidity: 95%. Application: Indoor use Detecting range: 30 sqm for normal area; and 20 sqm for high risk Visual Indicator: twin LED, Red ( lit steady when alarm, flashing at normal state) Material and colour: ABS, trafficwhite Wiring: 1 pair non polarized Dimensions: diameter 100mm; height 41mm without base HTTP://WWW.HOMBI.RU Digital Intelligent Dual Heat Detector DI-9103 Mounting Standard Base The digital detector should be installed in compliance with all local codes or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Codes, BS 5389 and EN54. The detector is mounted using our standard base DB-01 allows easy adjustment. Suitable for surface mount only, mount on standard 1gang electrical back box with a mounting hole of 45mm to 75mm spacing. Detector Installation Before installation verify the proper wiring and base are firmly mounted to prevent detector damage before the installation. Point the detector in the base by the markline and secure the detector in that position by rotating it clockwise until it reaches the next mark line. MARK 1 DETECTOR BASE Electrical Box 60 Conduit MARK 1 MARK 2 DETECTOR Base 78mm Detector 100m m 75 Programming The address and sensitivity of the detector can be programmed using GST handheld programmer (P-9910), purchased separately. Connect the two wires of the handheld programmer to any two opposite terminals of the detector. 60 45 DETECTOR TERMINAL Wiring and Connection Connect the wires to the required terminal according to the wiring diagram. Detector loop are connected on terminals 1 and 3 while for the remote indicator output, connect the wire on terminals 2 and4.The cable must be fire rated type and the size depends on the wiring distance. Minimum size gauge 1.0mm²(18 AWG). Selection of compatible Control Panels Compatible with all GST Intelligent Fire Alarm Panels GST 100, GST 200, GST 5000, GST 9000. Ordering Information: Part No DI-9103 1 2 60 DB-01 Description Digital Dual Heat Detector with Remote Indicator Detector Base Weight /Kg 0.090 Pack Qty per Box 120 0.049 360 MANUFACTURED IN ACCORDANCE WITH 3 4 E-MAIL: [email protected] FIELD DEVICE PROGRAMMER REMOTE INDICATOR Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intelligent Multi Sensor I-9101 The integral microprocessor analyses the signal according to the factors such as signal strength and rate of increase, then confirms these pattern with the preprogrammed fire scenarios and smoke patterns for a faster and safer response. By intelligent analysis, the smoke detection sensitivity will be automatically adjusted according to temperature change, providing a rapid response. Secure and speedy communication through the on board processor enables the detector to make its own decision, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. Features and Benefits 1. 2. Built in 8 bit microprocessor Algorithm maps for faster response and false alarm rejection 3. Analogue sensing 4. Secure and speedy communication 5. Patented Linear Drift compensation 6. Self diagnosis and history log 7. Electronic addressing 8. Sensing chamber for exceptional dust proof ability 9. Twin LED for 360º vision 10. Low profile design 11. Ideal alternative to Ionization detector Drift compensation, to monitor for the long term changes caused by aging, humidity, temperature, dust, etc. constant monitoring and self adjusting, the I-9101 updates sensitivity base line for its sensing element. Even when the detector raises a warning advising that it requires cleaning, the sensitivity remains the same as the day it was installed. Electronic addressing can be done through Handheld Programming device (P-9910), purchased separately. Technical Specifications Description Combining all the features of the I-9102 Optical and the I-9103 Dual Heat Detectors the unit provides an ideal solution for life and safety systems. Ideally suitable for application in data processing area including telephone exchange, conference rooms, indoor markets or shops, dining area, factory, recording studio and libraries etc. Aesthetically pleasing with a low profile design, unobtrusive to complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, Built-in A/D converter, Drift compensation, Self Diagnosis and history log. E-MAIL: [email protected] HTTP://GSTRU.RU • • • • • • • • • • • • • • Standard: EN54-part 5, part 6 and Part 7 Protection rating: IP 32 Operating voltage: 24Vdc Loop voltage Operating Current: Standby current 0.6mA Alarm Current 2mA Operating temperature:-10°C to +50°C Relative humidity: 95% Application: Indoor use Detecting range: 30 sqm for normal area; and 20 sqm for high risk Programmable sensitivity: 3 levels Visual Indicator: twin LED, Red ( lit steady when alarm, 3 sec interval blinking at normal state) Material and colour: ABS, off-white Wiring: 1 pair non polarized Dimensions: diameter 10cm; height 5cm HTTP://WWW.HOMBI.RU Intelligent Multi Sensor I-9101 ELECTRICAL BOX 1 GANG CEILING Mounting Standard Base The detector is mounted using our standard base DZ-03. Multiple-direction design allows easy direction adjustment. Suitable for surface mount only, mount on embedded box; 1gang UK standard. MARK−LINE 2ND MARK−LINE LED INDICATOR ROTATE CLOCKWISE EMBEDDED BOX CONCRETE PAD OR HOLDING PAD SCREW Programming The address of the detector and sensitivity can be programmed using GST handheld programmer (P-9910), purchased separately. Connect the two wires of the handheld programmer to any two opposite terminals of the detector. HOLE STANDARD DETECTOR BASE BASE MOUNTING Wiring and Connection Connect the wires to the required terminal according to the wiring diagram. The cable must be fire rated type and the size depends on the wiring distance and application. Minimum size gauge 1.0mm²(18 AWG) I−91XX DETECTOR TERMINALS 1 2 FROM CONTROL PANEL 1 PAIR FIRE CABLE DETECTOR TERMINAL MOUNTING FIELD DEVICE PROGRAMMER TO NEXT DEVICE 1 PAIR FIRE CABLE 4 3 Selection of compatible Control Panels Compatible with all GST Intelligent Fire Alarm Panels GST 100, GST 200, GST 500, GST 5000, GST 9000. Ordering Information: Detector Installation The Intelligent Multi sensor should be installed in compliance with all local codes having a jurisdiction in your area or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Code, BS 5389 and EN54. Before installation verify the proper wiring and base are firmly mounted to prevent detector damage before the installation. Point the detector in the base by the mark-line and secure the detector in that position by rotating it clockwise until it reaches the next mark line. E-MAIL: [email protected] Part No I-9101 DZ-03 Description Weight /Kg Intelligent Multi Sensor Standard Detector Base 0.123 Pack Qty per Box 120 0.050 360 MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intelligent Optical Smoke Detector I-9102 The integral microprocessor analysis the signal according to the factors such as signal strength and rate of increase, then confirms these pattern with the preprogrammed fire scenarios and smoke patterns for a faster and safer response. By intelligent analysis, the smoke detection sensitivity will be automatically adjusted according to temperature change, providing a rapid response. Secure and speedy communication through the on board processor enables the detector to make its own decision, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. Features and Benefits 1. 2. Built in 8 bit microprocessor Algorithm maps for faster response and false alarm rejection 3. Analogue sensing 4. Secure and speedy communication 5. Intelligent Linear Drift compensation 6. Self diagnosis and history log 7. Electronic addressing 8. Sensing chamber for exceptional dust proof ability 9. Twin LED for 360º vision 10. Built-in remote indicator output 11. Low profile design Drift compensation, to monitor for the long term changes caused by aging, humidity, temperature, dust, etc. constant monitoring and self adjusting, the I-9101 updates sensitivity base line for its sensing element. Even when the detector raises a warning advising that it requires cleaning, the sensitivity remains the same as the day it was installed. Electronic addressing can be done through Handhold Programming device (P-9910), purchased separately. Technical Specifications Description The I-9102 Optical Smoke Detector is the ideal device for most application due to its excellent linear response to a wide variety of different type of smoke patterns. The unit meets the sensitivity requirement of EN 54 part 7, European Standard and approved by Loss Prevention Certificate Board (LCPB). Aesthetically pleasing with a low profile design, unobtrusive to complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, Built-in A/D converter, Drift compensation, Self Diagnosis and history log. E-MAIL: [email protected] HTTP://GSTRU.RU • • • • • • • • • • • • • • • • Standard: EN54-part7 Approval: LPCB,CE Protection rating: IP 32 Operating voltage: 24Vdc Loop voltage Operating Current: Standby current 0.6mA Alarm Current 2mA Operating temperature: -10°C to +50°C Relative humidity: 95% Application: Indoor use Detecting range: 100 sqm elevated than 6m, 80 sqm less than 6m Field Programmable sensitivity: 0.10dB/m to 0.56dB/m – 3 level Visual Indicator: twin LED, Red ( lit steady when alarm, 3 sec interval blinking at normal state) Material and colour: ABS, off-white Wiring: 1 pair non polarized Dimensions: diameter 10cm; height 5cm HTTP://WWW.HOMBI.RU Intelligent Optical Smoke Detector I-9102 EMBEDDED BOX CONCRETE PAD OR HOLDING PAD Mounting Standard Base The detector is mounted using our standard base DZ-03.Multiple-direction design allows easy direction adjustment. Suitable for surface mount only, mount on standard 1gang electrical back box with a mounting hole of 65mm spacing MARK−LINE 2ND MARK−LINE LED INDICATOR ROTATE CLOCKWISE EMBEDDED BOX CONCRETE PAD OR HOLDING PAD SCREW HOLE STANDARD DETECTOR BASE BASE MOUNTING Wiring and Connection Connect the wires to the required terminal according to the wiring diagram below; terminal 1 and 3 for the loop; connection of remote indicator output is on terminals 2 and 4. The cable must be fire rated type and the size depends on the distance and application. Minimum size gauge 1.0mm²(18 AWG) Programming The address of the detector and sensitivity can be programmed using GST handhold programmer (P-9910), purchased separately. Connect the two wires of the handheld programmer to terminals 1 and 3 of the detector. I−91XX DETECTOR DETECTOR TERMINAL FIELD DEVICE PROGRAMMER TERMINALS TO NEXT DEVICE 1 PAIR FIRE CABLE 1 2 4 3 FROM CONTROL PANEL 1 PAIR FIRE CABLE Selection of compatible Control Panels Compatible with all GST Intelligent Fire Alarm Panels GST 100, GST 200, GST 5000 and GST 9000. REMOTE INDICATOR Ordering Information: Part No Detector Installation The Intelligent optical smoke detector should be installed in compliance with all local codes having a jurisdiction in your area or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Code, BS 5389 and EN54. Before installation verify the proper wiring and base are firmly mounted to prevent detector damage before the installation. Point the detector in the base by the mark-line and secure the detector in that position by rotating it clockwise until it reaches the next mark line. E-MAIL: [email protected] I-9102 DZ-03 Description Weight /Kg Intelligent Optical Smoke Detector with Remote Indicator Standard Detector Base 0.123 Pack Qty per Box 120 0.050 360 MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intelligent Dual Heat I-9103 Detector Meets the sensitivity requirement of EN 54 part 5 and part 6 European Standard and approved by Loss Prevention Certificate Board (LCPB). Aesthetically pleasing with a low profile design, unobtrusive to complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, Built-in A/D converter, Drift compensation, Self Diagnosis and history log. Secure and speedy communication through the on board processor enables the detector to make its own decision, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. Features and Benefits Dual fixed temperature heat detector. Combining both fixed temperature and rate of rise heat detection in a single sensor. As standard the fixed temperature is set to 66ºC while the rate of rise is set to 6ºC in one minute. The rate of rise function can be switched off and the fixed temperature can be adjusted between 54 and 74 degrees C 1. Built in 8 bit microprocessor 2. Algorithm maps for false alarm rejection 3. Analogue sensing 4. Secure and speedy communication 5. Drift compensation 6. Self diagnosis and history log 7. Electronically addressed 8. Twin LED for 360º vision 9. Low profile design 10. Built-in remote indicator 11. Fixed temperature response is adjustable via hand held programming tools. The integral microprocessor analysis the digital signal converted from analogue Electronic addressing can be done through Handhold Programming device (P-9910), purchased separately. Technical Specifications • • • • • • • • Description This detector is extremely reliable for application in places where may have high dust levels or smokey environments, making a normal smoke detector unsuitable , for example boiler/plant room, cars parks, kitchen, loading bays, furnace/kiln rooms. E-MAIL: [email protected] • • • • HTTP://GSTRU.RU • • • Standard: EN54-part5/ part6 Approval: LPCB,CE Protection rating: IP 22 Operating voltage: 24Vdc Loop voltage Operating Current: Standby Current 0.8mA Alarm Current 1.4mA Operating temperature: -10°C to +80°C Fixed Temperature adjustments: between 54ºC to 80°C Relative humidity: 95% Application: Indoor use Detecting range: 30 sqm for normal area; and 20 sqm for high risk Field Programmable sensitivity: 3 level Visual Indicator: twin LED, Red ( lit steady when alarm, 3 sec interval blinking at normal state) Material and colour: ABS, off-white Wiring: 1 pair non polarized Dimensions: diameter 10cm; height 5cm HTTP://WWW.HOMBI.RU Intelligent Dual Heat I-9103 Detector EMBEDDED BOX CONCRETE PAD OR HOLDING PAD Mounting Standard Base The detector is mounted using our standard base DZ-03.Multiple-direction design allows easy direction adjustment. Suitable for surface mount only, mount on embedded box; 1gang UK standard. MARK−LINE LED INDICATOR ROTATE CLOCKWISE EMBEDDED BOX CONCRETE PAD OR HOLDING PAD SCREW 2ND MARK−LINE Programming The address of the detector and sensitivity can be programmed using GST handhold programmer (P-9910), purchased separately. Connect the two wires of the handheld programmer to terminals 1 and 3 of the detector. HOLE STANDARD DETECTOR BASE BASE MOUNTING Wiring and Connection Connect the wires to the required terminal according to the wiring diagram below; terminal 1 and 3 for the loop; connection of remote indicator output is on terminals 2 and 4. The cable must be fire rated type and the size depends on the distance and application. Minimum size gauge 1.0mm²(18 AWG) I−91XX DETECTOR TERMINALS TO NEXT DEVICE 1 PAIR FIRE CABLE 1 DETECTOR TERMINAL 2 FIELD DEVICE PROGRAMMER FROM CONTROL PANEL 1 PAIR FIRE CABLE 4 3 REMOTE INDICATOR Compatible with all GST Intelligent Fire Alarm Panels GST 100, GST 200, GST 5000, and GST 9000. Detector Installation The Intelligent Dual Heat Detector should be installed in compliance with all local codes having a jurisdiction in your area or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Code, BS 5389 and EN54. Before installation verify the proper wiring and base are firmly mounted to prevent detector damage before the installation. Point the detector in the base by the mark-line and secure the detector in that position by rotating it clockwise until it reaches the next mark line. E-MAIL: [email protected] Selection of compatible Control Panels Ordering Information: Part No I-9103 DZ-03 Description Weight /Kg Intelligent Dual Heat Detector with Remote Indicator Output Standard Detector Base 0.123 Pack Qty per Box 120 0.050 360 MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intelligent Ultraviolet Flame Detector I-9104 The integral microprocessor analyses the signal according to the factors such as signal strength and rate of increase, then confirms these pattern with the preprogrammed fire scenarios and flame patterns for a faster and safer response. Secure and speedy communication through the on board processor enables the detector to make its own decision, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. Features: 1. 2. 3. 4. 5. 6. Built in 8 bit microprocessor Not sensitive to sunlight Dust /corrosion/humidity resistante Secure and speedy communication Self diagnosis and history log Standard calibration set to detect a 3cm flame at 6metres 7. Effective range up to 12 metres 8. 110º effective detection dispersion angle 9. Electronic addressing 10. Twin LED for 360º vision Electronic addressing can be done through Handhold Programming device (P-9910), purchased separately. Technical Specifications Description: • The I-9104 Intelligent Ultraviolet Flame Detector is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance, used in high hazard applications such as petrochemical plants, munitions factories and other areas where flammable or explosive liquids or solids are handled or stored. The I-9104 sensor provides an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosionproof and moisture-resistant. The sensor is not sensitive to sunlight, dust, oil, fume, and humidity. Set as a standard calibration to detect a 3cm flame at a distance of 6 meters with a total effective range of 12 meters. Has unique electronic addressing to provide specific location, information and monitor condition. E-MAIL: [email protected] • • • HTTP://GSTRU.RU • • • • • • • • Protection rating: IP 32 Operating voltage: 24Vdc Loop Operating Current: Standby current 1.5mA Alarm Current 10mA Operating temperature:-10°C to +50°C Relative humidity: 95% Application: Indoor use Detection angle: 80 degree Programmable sensitivity: 3 levels Visual Indicator: LED, Red ( lit steady when alarm, 3 sec interval blinking at normal state) Material and colour: ABS, off-white Wiring: 1 pair non polarized Dimensions: diameter 10cm; height 5cm HTTP://WWW.HOMBI.RU Intelligent Ultraviolet Flame Detector I-9104 EMBEDDED BOX CONCRETE PAD OR HOLDING PAD Mounting Standard Base The detector is mounted using our standard base DZ-03.Multiple-direction design allows easy direction adjustment. Suitable for surface mount only, mount onto standard one gang electrical box with a mounting hole that have 65mm spacing. MARK−LINE 2ND MARK−LINE LED INDICATOR ROTATE CLOCKWISE EMBEDDED BOX CONCRETE PAD OR HOLDING PAD Programming SCREW The address of the detector and sensitivity can be programmed using GST handheld programmer (P-9910), purchased separately. Connect the two wires of the handheld programmer to any two opposite terminals of the detector. HOLE STANDARD DETECTOR BASE BASE MOUNTING Wiring and Connection Connect the wires to the required terminal according to the wiring diagram. Terminal 1 and 3 is for loop bus. The cable must be fire rated type and the size depends on the distance and application. Minimum size gauge 1.0mm². I−91XX DETECTOR TERMINALS 1 2 FROM CONTROL PANEL 1 PAIR FIRE CABLE DETECTOR TERMINAL MOUNTING FIELD DEVICE PROGRAMMER TO NEXT DEVICE 1 PAIR FIRE CABLE 4 3 Selection of compatible Control Panels Compatible with all GST Intelligent Fire Alarm Panels GST 100, GST 200, GST 5000, GST 9000. Detector Installation Ordering Information: The Intelligent sensor should be installed in compliance with all local codes having a jurisdiction in your area or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Code, BS 5389 and EN54. Before installation verify the proper wiring and base are firmly mounted to prevent detector damage before the installation. Point the detector in the base by the mark-line and secure the detector in that position by rotating it clockwise until it reaches the next mark line. Part No E-MAIL: [email protected] I-9104 DZ-03 Description Weight /Kg Intelligent Ultraviolet Flame Detector Standard Detector Base 0.123 Pack Qty per Box 120 0.050 360 MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intelligent Reflective Beam Detector I-9105R Built-in intelligent microprocessor, the detector has strong ability of analysis and judgment. The detector automatically carries out system adjustment, compensation and variation of ambient data. Secure and speedy communication through the on board processor enables the detector to make its own decision, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios The detector is ideally suited to historical buildings, warehouses, large storages, shopping malls, leisure centres, exhibition halls, hotel lobbies, printing houses, clothing factories, museums and prisons, as well as places where slight smoke particles or corrosive gas exist. Features and Benefits 1. Wide monitoring area, range 8-100 metres 2. Combination of the emitting and receiving parts makes mounting easy and accurate optical pathway 3. Simple and cost effective to install transmitter and reflective via ‘honey comb’ mirror. 4. Quick and easy to set up, visual strength indication. 5. Built-in microprocessor 6. Self-diagnosis function can monitor for internal faults 7. Automatic compensation for factors weakening received signals, such as dust contamination, positional movement and ageing of the transmitter. 8. Electronically addressed 9. Three selectable lavels of sensitivity adjustment. 10. SMT processing technology 11. Attractive and pleasing appearance Technical Specifications • • • • • • • • • • • • • • • Standards: BS EN54 Part-12 Approvals: LPCB, CE Protection Rating: IP20* Operating Voltage Power Voltage: 24Vdc (±10%) Loop Voltage: 24Vdc Operating Current Standby current: 12mA Alarm current: 22mA Length of Optical Pathway: 8-100meter Monitoring width: 14m Monitoring Area: 1400m² Operating Temperature: -10°C to +50°C Field Programmable Sensitivity: 3 levels Relative humidity: 95% Application: Indoor use Material and Colour: ABS, Gray Wiring: 1 pair -24Vdc, 1pair- loop Dimensions:206mmX95mmX95mm Description Indication of Detector Status I-9105R Intelligent Reflective Beam Detector works on the principle of reflective infrared beam smoke detector that can be directly connected to a fire alarm loop. Transmitting status information via the loop between the detector and controller. The detector must be used together with a reflector. The number of reflector(s) to be used (one or four) depends on the distance from the detector. Commission: Green LED and Yellow LED are lit or flash in a sequence. Normal monitoring state: Red LED flashes periodically (with loop connected) Fire: Red LED constantly illuminates, and Yellow LED turns off. The fire signal has to be reset by the controller Fault: Yellow LED constantly illuminates. E-MAIL: [email protected] HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intelligent Reflective Beam Detector I-9105R Wiring and Connection Connect the wires to the required terminal according to the wiring diagram. The D1, D2 is for 24VDC power supply. The Z1, Z2 for loop. The cable must be fire rated and the size depends on the distance and application. The minimum size gauge 1.0mm² LOOP IN LOOP OUT TO POWER SUPPLY 24VDC D1 D2 Z1 Z2 Mounting the Detector Selection of compatible Control Panels The Intelligent beam detector should be installed in compliance with all local codes having a jurisdiction in your area or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Code, BS 5389 and EN54. The detector can be mounted in 2 ways: the installed onto standard two gang electrical box, or directly by drilling the holes and fixing with plugs. Compatible with all GST Intelligent Fire Alarm Panels GST 200, GST 500, GST 5000, GST 9000. E-MAIL: [email protected] Ordering Information: Part No I-9105R Description Weight /Kg Intelligent Reflector Beam Detector 1.3 Pack Qty per Box 10 MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Addressable Gas Detector I-9602LW Technical Specifications • • • • • Features and Benefits 1. 2. 3. 4. 5. 6. 7. 8. Build-in microprocessor Self-diagnosis function can monitor the inner fault. Built-in relay contacts for control Gas Valve/Extract etc. Built-in Sounder Manual reset and control of relays contact. Electronically addressed Wall mounting. Easy installation and connection. Available in LPG, Coal Gas and natural Gas • • • • • • • Description I-9602LW Addressable Gas Detector is suitable to detect liquefied petroleum gas in such areas as houses, hotels and apartments. This detector is available for different application such as LPG, Natural Gas and Coal gas. (Please specify at the time of order). The detector adopts semiconductor gas sensitive components enabling stable operation and simple installation. It's powered by centralized DC24V that can be connected with GST fire alarm controller by non-polarized two-wire, to form a loop type fire alarm system together with other detectors. It has two alarm levels: level 1 and level 2. E-MAIL: [email protected] HTTP://GSTRU.RU • • • • • • • • • • Protection rating: IP30 Operating Voltage: Loop Voltage: 24V Range Allowed: 16V 27V Power Bus Voltage: DC24V Range Allowed: DC16V DC30V Operating Current: Standby Current: 80mA (power bus); 2.7mA (signal bus) Alarming Current: 100mA (power bus) ; 5.2mA (signal bus) Output Capacity and Control Mode: A group of one-way DC pulse active contact (1000μcapacitance discharge). A group of passive normally open contact. Alarm Density: Level 1 3080ppm (14% LEL) Level 2 4400ppm (20% LEL) Indicators: Power Supply LED: Green constantly lit in operation. Alarm LED: Red, flashes per 4s-5s in polling. Flashing frequency is about 1Hz in level 1 and about 3Hz in level 2. Fault LED: Yellow, constantly lit when in fault. Programming Mode: Electronic programming within 1-242. Life of Sensor: 5 years Operating Environment: Temperature: 0ºC~ +50 ºC Relative Humidity≤95%, no condensation Dimension: 176mm×80mm×45mm Material and Color of Enclosure: ABS, ivory white Signal two-wire, non-polarized. Weight: 230g Mounting Hole Distance: 156mm HTTP://WWW.HOMBI.RU Addressable Gas Detector I-9602LW Mounting Gas Detector The installation of gas detector should comply with all local codes and / or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Code. Designed to install onto standard conduit electrical box (70mmx70mm). Recommended location of the detector is show below. Knock- of f Hol e Output Socket Programming The address gas detector can be programmed using GST handhold programmer (P-9910), purchased separately. Connect the two wires of the handheld programmer to terminals Z1 and Z2 of the detector. Ceiling Smoke Exhauster Natural Gas and Coal Gas Detector ¡Ý Gas Stove cm 1. 5m70dBA Operating temperature: -10°C to +40°C Relative humidity: 95% Application: Indoor use Material and colour: ABS,white, red Wiring: 1 pair polarized Dimensions: 234 x 146mm x 60mm Selection of compatible panel 9 GST-FT24 24Zone Conventional Fire Panel Centre 9 GST-FT8W 8Zone Conventional Fire Panel Centre Features and Benefits 1. 2. 3. Fixed extension of fire telephone System Box for total protection. Wall Mounted and easy installation Description Ordering Information: Part No Description P-9911(F) Fire Telephone Handset Weight /Kg Pack Qty per Box Note: Specifications are subject to change without notice. P-9911(F) is a telephone jack socket, normally located at various places. Common installation positioning is in the landing levels of all core stairwells and escape routes, although the exact positioning is the responsibility of the project designer. The person on site with a mobile handset may just plug & talk to the control center. The unit should be mounted in a suitable and dry location at about 1.5m from finished floor level. Wiring and Connection The fixed can be installed with standard electronic back box, which the mounting hole distance is 60mm. Connect the cable to the terminals. No need addressing. Connections refer to FT panel manual. E-MAIL: [email protected] HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Conventional Fire Telephone PanelGST-FT24 Operation The GST FT24 provides two methods of calling, i.e. from the hand set to the relevant remote zone or from the remote telephone point to the control centre. Call Handset.From the control centre, press Features and Benefits 1. 2. 3. 4. 5. 24 Zone conventional fire telephone center. 2-way voice communication Operator can select single or group call Operator can ring outstations and fixed handsets Up to 10 communication points can be connected to each zone Description The GST Fireman’s Telephone (GST-FT24) system is a dedicated audio communication system linking directly to the fire control center, providing 2-way speech between the fire team and the Central Command Controller. Usually the GST FT system is installed in high-risk buildings where radio communication would be limited due to the extensive concrete structure. The GST FT-24 is a 24-zone system radially wired (2 core) with up to 10 communication points on each zone. The system includes single and multi channel (group) communication, Audio recording of conversations, Monitored cable protection. Technical Specifications • • • • • • • • • • • System Capacity: 24 communication zone Frequency Range:300-3400Khz Cross Talk: <-60dB Audio Feedback:<5dB Zone Accepted Resistance: <1KΩ Power Supply: 24Vdc Operating Current: 500mA Operating temperature: 0°C -40°C Relative humidity: 45% to 95% Application: Indoor use Dimensions: 132.5x482.6x225mm E-MAIL: [email protected] the relevant zone connect button, this will make the relevant handset ringing. (Or sets ring depending on the quantity of handsets connected to that specific zone). When that zone is activated the field handsets will ring, to establish audio communication simply pick up the handset, or for the hands-free version, just press the talk button), communication is achieved. Press button again in the control centre to cancel the call. Call Control Center. Make the zone active (Fixed handset - pick the phone. Speaker handset - press the button. Socket - insert the mobile handset), will make the control panel alarm with LED zone indication. From the control centre, press the corresponding button to achieve communication. Group Call. The fire telephone panel can talk to more than one handset. Simply by Pressing all the desired zone buttons on the control panel, This will allow group communication. To add or cancel more users simple select or deselect the relevant zone. Audio Record. Whenever you start audio communication, the electronic recorder will automatically record the conversation. There is a total memory capacity of 99 records (indicated by the digital-LED). The records can be played back, with the last communication first. The operator can skip to the desired message for play back by simply using and to step through to the desired recording. Audio Output. A line level audio out put is provided should the system require to be linked to a public address or Voice alarm system. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Conventional Fire Telephone PanelGST-FT24 System Configuration The GST FT24 is mounted in a standard 19” rack enclosure. The system is wired in radial conventional zones. In each zone it is possible to mix fixed handsets, speaker handset and Jack sockets. The panel is standard 3U console mount type, can be installed together with the fire alarm control panel GST5000 or GST9000 (both rack and console type). Connect 24VDC to the terminals on the rear of the panel. Connect the zones to the panel with minimum 2 core 1.0mm2 cable. Regularly Test. As with all Life safety equipment regular testing should be carried out, we would recommend that all zones are tested at least every 3 months or as indicated by your local fire authority requirements. E-MAIL: [email protected] Selection of GST-FT24 compatible fire telephone P-9911(S) Speaker Fire Telephone Station P-9911(F) Fixed Fire Telephone Handset P-9911(J) Fire Telephone Jack Socket P-9911(M) Fire Telephone Mobile Handset Ordering Information: Part No Description Weight /Kg GST-FT24 Conventional Fire Telephone Panel 6 Pack Qty per Box 1 Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU E-MAIL: [email protected] HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU CyberNet Touch Screen Controller GST8101 Features and Benefits 1. 10.4” TFT touch screen 2. Powerful and user friendly operation GST8101S 3. Supports Windows 98/2000/XP 4. Full system monitoring, indicating operation of each unit 5. Capable of controlling 99 zones 6. Up to 3 Touch screen controllers per system. Description The GST8101 provides a fully loaded user friendly Touch screen controlled PC front end, providing a flexible management window to the entire system. Enabling both Engineers to configure all aspects of the system, while system managers can configure and control the day to day operation of the system. This includes back ground music source selection, volume control routing to any individual area, zone or group of zones, Up to three Cybernet touch screen controllers can be utilized on any one system. Technical Specification • • • • • • • • • E-MAIL: [email protected] Power Supply: Power consumption: Baud rate: Communication protocol: Communication terminal: Rack space: Case Materials: Dimension: Net weight: 220Vac±10%/50Hz ; 24Vdc±10% 300 Watts 9600bps RS 232 DB9 10U Black aluminum steel 484 X 265 X 430mm 8.5 kg MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Master Controller GST8102 Features and Benefits 1. Master controller of complete system up to 99 zones. 2. Automated intelligent programmable processor control. 3. Can stores 500 system events 4. Program downloaded from GST8101 or computer with GST8101Software 5. Large LCD screen display 6. User friendly menu operation 7. Allows manual control of amplifiers 8. Communicating monitoring control with entire system 9. Self-diagnostics 10. Built in battery box 11. 220 AC / 24V DC operation Description The GST8102 is the heart of the system providing direct communication and programming of all VA modules. The Master Controller provides complete reporting and fault diagnostics. Technical Specification Power Supply AC220V±10%/50/60 HZ Power Consumption 30Watts Keypad 1 Direction Key;9 Function Keys;2 Shortcut Keys Display 192X64 LCD, English Menu;2 LED Fault Indicators Communication Protocol RS-232, DB9, IN;RS422, RJ45, OUT Baud Rate Case Material Back up Supply Net Weight E-MAIL: [email protected] 4800bps Black Stainless Steel Battery 17AH/24VDC with battery box 12.5kg (without battery) MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Audio Processor GST8103 Features and Benefits 1. Simultaneous broadcast of 6 audio channels. Providing Selection and controlled from any number of sources. 2. Support 8 emergency microphones within 500 metres. 3. Individual volume display for each channel 4. Forced switch terminal operations by program in case of emergency 5. Self-diagnostics 6. 220 AC / 24V DC operation Description The audio process controls and manages six audio channels, three channels dedicated to voice alert and evacuate message, with three more channels dedicated to background music sources and manual paging. Technical Specification Power Supply AC220V±10%/50/60 HZ Power Consumption 60Watts Keypad 1 Direction Key;9 Function Keys;2 Shortcut Keys Display LCD, level Indicator Communication Protocol RS422, RJ45, In;DB15 to microphone; Screw types to amplifiers Channel Insulation ›40dB Volume Adjustment -∞ to 0 dB S/N Ratio 95dB Baud Rate 4800bps Audio Input 6 channels, RCA connector ; 10kΩ/0.775V Audio Output 6 channels, screw fixing Rack Space & Dimension 3U: 555 X 555 X 235mm Case Material Back up Supply Net Weight E-MAIL: [email protected] Black Stainless Steel Battery 17AH/24VDC with battery box 12.5kg (without battery) MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Emergency Interface GST8104 Features and Benefits 1. Emergency zonal signal interface provides a programmable interface with GST intelligent Fire detection systems 2. Micro-processor controlled 3. 30 zones input, expandable to 99 zones 4. Ideal for fire alarm control of phased evacuation. 5. Self-diagnostic 6. 220 AC / 24V DC operation Description The Emergency Interface provides a simple and reliable interface to any fire alarm system. The GST8101S can perform the most complicated cause and effect with care. Technical Specification Power Supply: Power consumption: Communication protocol: Communication terminal: No of inputs: Input Mode: Rack Space Colour and Materials Dimension: Net weight: E-MAIL: [email protected] 220Vac±10%/50Hz ; 24Vdc±10% 15 Watts RS 422 RJ45 30 inputs N/O dry contact 2U Black, Alloy aluminum 484 X 350 X 88mm 4.3 kg MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Emergency Message Generator GST8105 Features and Benefits 1. Micro-processor controlled message store for Alert, Evacuate, Clear and Test 2. Can broadcast 2 types of message simultaneously 3. Can broadcast Evacuate and Alert even master controller is malfunction. 4. Massages can be re-recorded locally. 5. Up to 200 seconds of digital recording 6. Self-diagnostics 7. 220 AC / 24V DC operation Description The Emergency Message Generator stores up to four non volatile messages of up to 50b seconds in length. The message can be accessed independently and broadcast to any combination of zones. Technical Specification Power Supply AC220V±10%/50/60 HZ Power Consumption 30Watts Display 6 LED, level Indicator Communication Protocol RS422, RJ45, IN/OUT Channel Insulation ›40dB Volume Adjustment -∞ to 0 dB S/N Ratio 95dB Baud Rate 4800bps Frequency Range 30-20Khz Record Input Terminals 6.5mm jack;Mic: 600Ω/10mV; Line: 10kΩ/0.775V Audio Output Terminals 2 channels, 6.5mm jack, 1kΩ/0-1.5V Rack Space & Dimension Case Material Back up Supply Net Weight E-MAIL: [email protected] 3U: 555 X 555 X 235mm Black Stainless Steel Battery 17AH/24VDC with battery box 12.5kg (without battery) MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Emergency Microphone GST8106 Features and Benefits 1. Desk top configuration. 2. Fist Microphone 3. Highest priority access to system 4. Directly connecting to audio processor GST8103 ,maximum 500 meters 5. Simple operation capable of broadcasting to 9 SINGLE AREA CALL (node) 9 ZONAL CALL 9 All CALL 9 CLEAR and TEST 6. Simple action of broadcasting All Evacuate, All Clear, Reset and Zonal Test 7. With Chime, microphone, auxiliary volume control 8. Self-diagnostics 9. LED status and zonal indication 10. 24Vdc operation Description The Emergency Microphones provides complete and precise emergency management of the entire system. The security or fire officer can quickly and accurately relay live voice announcement to any single or multi zones or all call. Manual evacuation, test, all clear can be initiated from this station. Technical Specification Power Supply 24Vdc Power Consumption 30Watts Keypad 99 Zonal keys, 6 function keys Display LED indicator in each key Communication Protocol RS422, DB9 In/Out Chime type Microphone type 1 Fist microphone/600Ω/10mV Sensitivity -62dB Volume Adjustment -∞ to 0 dB S/N Ratio 95dB Baud Rate 4800bps Frequency Range 20-20Khz Numbers in series 8 microphones within 500 meters Dimension Case Material 245 X 65 X 315mm Silver Alloy-Aluminum Net Weight E-MAIL: [email protected] 3.5Kg MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU CD Player GST8180 Features and Benefits 1. Single CD player 2. Micro-processor controlled 3. Local control 4. Programmed flexibly controlled by TW-010 5. Self-diagnostics 6. 220 AC / 24V DC operation Description The CD Players provides high quality sampling of CD’s in both standard format and MP3 format. The CD is fully programmable and ultimately reliable Technical Specification Part Number: Power Supply: Power consumption: Output voltage: Communication protocol: Communication terminal: Frequency range: Rack Space Colour and Materials Dimension: Net weight: E-MAIL: [email protected] GST8180 220Vac±10% 30 Watts 0.75V RS 422 RJ45 50-15000Hz 2U Black, Alloy aluminum 484 X 350 X 88mm 6 kg MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Digital Tuner GST8181 Features and Benefits 1. 2. 3. 4. 5. 6. Micro-processor controlled Backlight LCD display Local /remote channel selection FM/AM 99 individuals presetting Accurate frequency control Self -diagnostics Description The Digital Tuner is ideal for background music , the tuner provides up to 99 pre-programmed radio stations for excellent music selection Technical Specification Part Number: Power Supply: Power consumption: Output voltage: Communication protocol: Communication terminal: Frequency range: Rack Space Colour and Materials Dimension: Net weight: E-MAIL: [email protected] GST8181 220Vac±10% 30 Watts 0.75V RS 422 RJ45 50-15000Hz 2U Black, Alloy aluminum 484 X 350 X 88mm 6 kg MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Node Terminal Addressable Amplifier GST8330/60 Features and Benefits 1. Addressable amplifier 2. 6-channels input 3. 100V/ output 4. Local 3 BGM channel input 5. Maximum volume override in case of emergency 6. Speaker loop monitoring 7. With 2 cooling fan 8. Built in battery box 9. Self diagnostics 10. With security lock and 2 LED’s indicator 11. 220 AC / 24V DC operation Description The Node Terminals Addressable Amplifier range provides truly distributed voice evacuate plus background music system. The amplifier is mounted in self contained enclosures combined with power supply and battery space. Distribution of amplifiers provides excellent wiring saving capabilities and enhanced local control is achieved via three direct audio inputs and volume control with master override. Technical Specification Model GST8330 GST8360 Power Supply AC220V±10%/50/60 HZ Back-up Battery 17 AH / 24 Vdc Power Consumption 60Watts 120Watts Power Output 30Watts 60Watts Keypad 99 Zonal keys, 6 function keys Display 2 LED indicator for power and fault Communication Protocol RS422, Screw fixing, In/out Channel Control Input 1, Screw fixing Channel Insulation ›40dB S/N Ratio 95dB Baud Rate 4800bps Frequency Range 30-20Khz Dimension Case Material 415 X 343 X 135mm Dark-grey coated steel sheet Net Weight E-MAIL: [email protected] 18.5kg excluding battery MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Node Terminal Addressable Amplifier (Rack Mount Type) GST83R Series Features and Benefits 1. 2. 3. 4. 5. 6. 7. 8. Addressable amplifier 6-channels input 100V/70V output Local 3 BGM channel selection and 32 level volume control Maximum volume override in case of emergency DC speaker line monitoring Self diagnostics 220 AC / 24V DC operation Description The Node Terminals Addressable Amplifier range provides intelligent addressable distributed voice evacuate plus background music system. The amplifiers are rack mounted with integral power supply and battery space. Option intelligent soft start power supply to avoid inrush current use TW 090 is achieved via three local audio inputs and volume control with master override Technical Specification Part Number GST8330R Power Output GST3240R 100W 200W 400W 600W 60W 120W 240W 350W Output Mode 100V/70V Frequency Range 20-15000Hz ±3dB Channel Isolation >40dB SNR Distortion >70dB <0.1% Comm Protocol Comm terminal Rack Space RS-422 RJ45 3U Case Material Black Alloy-Aluminum Dimension Net Weight E-MAIL: [email protected] GST8350R AC220V±10%/50HZDC24V±10% Power Supply Power Consumption GST83120R 484×450×132mm 11kg 13kg 18kg 21.5kg MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Ceiling Speaker GST8401 Features and Benefits • • • • • Full range ceiling speaker Ideal for emergency and music broadcasting. Simple installation from underside of ceiling tile No visible fixing screw High temperature ceramic termination block Technical Specification E-MAIL: [email protected] Model Operation Voltage Rated Power Max. Power Sound Level (@6W/1W, 1kHz,1M) Frequency Range Transformer Tapping Opening Angle GST8401 70/100V 6W 9W 94dB/88dB(SPL) 80Hz to 18kHz 1.5W, 3W, 6W 150° UL 1411 / IEC 268-5 / UL94 V0 / EN60065 Fire Resistance ABS Steel White (RAL 9010) 650g 152.4mm 198X91.44 mm -25°C to +55°C Compatible Standard Case Material Grid Material Color Weight Speaker Size Total Dimension Operation Temperature M A NUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Wall Mount Speaker GST8411 Features and Benefits • • • • Full range wall mount speaker Ideal for emergency and music broadcasting. Simple installation from underside of ceiling tile Ideal for corridors, stairs, lift lobby, plants rooms and hotel back house areas. Technical Specification E-MAIL: [email protected] Model Operation Voltage Rated Power Max. Power Sound Level (@6W/1W, 1kHz,1M) Frequency Range Case Material Grid Material Colour Weight Total Dimension Operation Temperature GST8411 100V 10W 15W 89dB±3dB(SPL) 120Hz to 15kHz High quality plastic PVC Steel White (RAL 9010) 2.2 Kg 215x170x150 mm -25°C to +50°C MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Pendant Speaker GST8421 Features and Benefits • • • • • High quality sound pendant speaker Luxurious silver-gray plastic cabinet With strong metal fixing bracket Ideal for use in a modern building interior Ideal for indoor hall, supermarket, stores and high ceiling environments Technical Specification E-MAIL: [email protected] Model Speaker Unit Operation Voltage Rated Power Max. Power Sound Level (1W,,1M) Frequency Range Transformer Tapping Terminals Case Material Grid Material Color Weight Total Dimension GST8421 5” woofer paper 70/100V 9W 9W 95dB±3 (SPL) 110Hz to 13kHz 3W, 6W, 9W 4-core Plastic Plastic Silver-gray 1.45Kg Ǿ172x285mm HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Sound Projector GST8431 Speaker Features and Benefits • • • • High quality double sound projector for voice evacuate and PA system Waterproof light-aluminum alloy cabinet and bracket With strong metal fixing bracket for wall or ceiling mount Ideal for corridors, car parks, stair lobbies, plaza, swimming pool, exhibition room, factories and plant rooms Technical Specification E-MAIL: [email protected] Model Operation Voltage Rated Power Max. Power Sound Level (@6W/1W, 1kHz,1M) Frequency Range Case Material Grid Material Color Weight Total Dimension GST8431 100V 10W 15W 102dB±3 (SPL) 250Hz to 8 KHz Aluminum alloy Steel White 2.1Kg 102 NUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Horn Speaker GST8441 Features and Benefits • • • • • High efficiency horn speaker Wide frequency response and high SPL Waterproof white plastic suitable for all types of weather Durable construction ensures long term reliable operation Ideal for car parks, warehouses, plant rooms and noisy production area. Technical Specification Model Operation Voltage Rated Power Max. Power Sound Level (@1M) Frequency Range Impedance Case Material Colour Weight Dimension E-MAIL: [email protected] GST8441 70/100V 15W,25W 25W 113dB±3 (SPL) 250Hz to 8kHz 280Ω, 410Ω plastic White 3.2Kg 285x285x210 mm HTTP://GSTRU.RU GST8442 70/100V 10W 10W 103dB±3 (SPL) 250Hz to 8kHz 680Ω, 1.1KΩ plastic White 7Kg 285x285x210 mm HTTP://WWW.HOMBI.RU 9” Equipment Rack GST86033/86039 Features and Benefits • • • • • Ideal for Public address and Voice alarm System U’s Available in 39,33 and 27 Built-in 2 fan tray Removable side panels Easy to construct Technical Specification Model Dimension:mm Weight: Kg Material Equipment patter U’s available Side panels Front panel Back panel Air Cooling Cable running E-MAIL: [email protected] GST86039 1820x600x650 60 GST86033 1555x600x650 50 Aluminum 19” EAI hole patter 39U 33U Removable Lockable glass door Lockable 2 Fan Tray Cable manageable MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU E-MAIL: [email protected] Explosion Proof and Intrinsically Safe Product HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Digital Flame Proof Ultraviolet Flame Detector DI-9104EXD Technical Specifications Operating Voltage Operating Current Power-up Time Indicator Wiring Features: • • • • • • • • • • • • Programming Mode Intelligent signal-processing and communication with integrated microprocessor. Intelligent algorithm ensures quick response with reduced false alarm. Three sensitivity levels. High sensitivity, reliable performance. Dust /corrosion/humidity resistante Secure and speedy communication Self diagnosis and history log Effective range 12 to 25 metres Electronic addressing Loop Powered Twin LED for 360º vision Mounting bracket support wall or ceiling mount. Address Range Spectrum Response Range Detection Angle Detection Distance Ingress Protection Ambient Temperature Relative Humidity Dimensions Material and Color Description: DI-9104Exd is a light-sensitive detector that detects fire by picking up the ultraviolet light from flaming material. It’s designed for areas where an open fire is liable to occur with large amount of radiation, with no smoldering stage, or where quick response to a fire is required. This detector can be applicable to zone 1 and 2 of explosive areas Secure and speedy communication through the on board processor enables the detector to make its own decision, resulting in greater automation. The sensor and the panels utilized fuzzy logic providing an almost limitless cause and effect scenarios. Weight Installation Hole Spacing Explosion-proof Mark Explosion-proof certificate Standards to comply with in design Loop voltage: 24V Standby current ≤ 2mA Action current ≤ 2.5mA ≤5s Red. It flashes when polling, and illuminates steadily in alarm. Two wire connection with FACP, polarityinsensitive. Electronic programming. Occupying one loop address. 1-242 185nm-260nm 25m for Level I, 17m for Level II and 12m for Level III. IP66 -20°C to +40°C ≤95%RH, noncondensing 147mm×103mm×92mm ZL102 Aluminum alloy, silvery grey. 1.5kg 110mm×72mm Ex d0CT6 CE061027 EN 54-10 GB 3836.1 GB 3836.2 IEC 60079-0 IEC 60079-1 Electronic addressing can be done through Handhold Programming device (P-9910), purchased separately. E-MAIL: [email protected] HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Digital Flame Proof Ultraviolet Flame Detector DI-9104EXD Connection and Wiring Ordering Information: Screened 2-core cable with cross section 1mm2 or above, and outer diameter φ8 mm is required for field wiring., ZI and Z2 for the loop. Safety Area Part No Description Weight/ Kg DI-9104EXD Digital Flame Proof Ultraviolet Flame Detector Expansion Bolt M6×60 Screws M3×16 1.5 Hazardous Area Pack Qty per Box 120 3 2 FACP Z2 Z1 MANUFACTURED IN ACCORDANCE WITH DI-9104Exd Detector Installation Note: The detector shall be installed in compliance with relative installation codes. Make sure the housing is in good condition. E-MAIL: [email protected] Note: Specifications are subject to change without notice. M6×60 M3 × HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Innovation Conventional Flame Proof Ultraviolet Flame Detector DC-9104EXD Technical Specifications Operating Voltage Operating Current Power-up Time Indicator Wiring Spectrum Response Range Detection Angle Features: • • • • • • • Communication with integrated microprocessor. High sensitivity, reliable performance. Dust /corrosion/humidity resistante Secure and speedy communication Effective range 12 to 25 metres Twin LED for 360º vision Mounting bracket support wall or ceiling mount. Description: DC-9104Exd is a light-sensitive detector that detects fire by picking up the ultraviolet light from flaming material. It’s designed for areas where an open fire is liable to occur with large amount of radiation, with no smoldering stage, or where quick response to a fire is required. This detector can be applicable to zone 1 and 2 of explosive areas E-MAIL: [email protected] Detection Distance Ingress Protection Ambient Temperature Relative Humidity Dimensions Material and Color Weight Installation Hole Spacing Explosion-proof Mark Explosion-proof certificate Standards to comply with in design HTTP://GSTRU.RU Loop voltage: 24V Standby current ≤ 2mA Action current ≤ 2.5mA ≤5s Red. It flashes when polling, and illuminates steadily in alarm. Two wire connection with FACP, polarise 185nm-260nm 17m IP66 -20°C to +40°C ≤95%RH, noncondensing 147mm×103mm×92mm ZL102 Aluminum alloy, silvery grey. 1.5kg 110mm×72mm Ex d0CT6 CE061027 EN 54-10 GB 3836.1 GB 3836.2 IEC 60079-0 IEC 60079-1 HTTP://WWW.HOMBI.RU Innovation Conventional Flame Proof Ultraviolet Flame Detector DC-9104EX Connection and Wiring Ordering Information: Screened 2-core cable with cross section 1mm2 or above, and outer diameter φ8 mm is required for field wiring., ZI and Z2 for the loop. Safety Area FACP Part No Description Weight/ Kg DC-9104EXD Innovation Conventional Flame Proof Ultraviolet Flame Detector Expansion Bolt M6×60 Screws M3×16 1.5 Hazardous Area Z2 Z1 Pack Qty per Box 120 3 2 MANUFACTURED IN ACCORDANCE WITH DI-9104Exd Detector Installation Note: The detector shall be installed in compliance with relative installation codes. Make sure the housing is in good condition. E-MAIL: [email protected] Note: Specifications are subject to change without notice. M6×60 M3 × HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Explosion Interface I-9332 Technical Specifications • Operating Voltage: Bus Voltage: 24V Range Allowed: 16V28V Power Voltage: 24VDC Range Allowed: 20VDC 28VDC • Operating Current: Standby Current≤0.5mA Alarm Current≤5mA • Programming mode: Electronic programming within 1-242, occupying one loop address. • Wiring: Non-polarized two-bus with the controller; non-polarized two-wire with DC24V power cable; polarized two-wire with explosion-proof devices. • Operating Environment: Features and Benefits 1. 2. 3. 4. Interface for Intrinsically safe detectors and manual call point Electronically addressed Microprocessor supervises running status and gives diagnosis message. With a built-in safety barrier, the interface can directly match with intrinsically safe devices. Temperature: -10°C+5°C Relative Humidity≤95%, no • • • • • Description I-9332 Interface can match with explosionproof devices (explosion-proof smoke detector, heat detector, combination smoke/heat detector or manual call point) to form an intrinsically safe system. When fire occurs, the interface sends alarm signal to fire alarm controller through loop and the controller will give alarm signal and display the alarm address of the interface. When the interface itself is in fault, the controller will give fault signal and display the fault address of the interface. • Selection of compatible Control Panels Compatible with all GST Intelligent Fire Alarm Panels. Ordering Information: Part No I-9332 Electronic addressing can be done through Handheld Programming tool (P-9910), purchased separately. E-MAIL: [email protected] condensation Dimension: 200mm×162mm×85mm Safety Barrier Parameters: U0=28V, I0=93mA, L0=4.3mH, C0=0.04μF Weight: 1.5kg Mounting Hole Spacing: 192mm 212mm Material and Color of Enclosure: Q235A, grayish white Ingress Protection level: IP 33 Description Weight/ Kg Addressable Interface for Detectors & MCP including Zener Safety Barrier-Ex .180 Pack Qty per Box 120 MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Explosion Interface I-9333 Technical Specifications • • • • • • Features and Benefits 1. 2. 3. 4. Interface for Intrinsically safe sounder and sounder strobe Electronically addressed Microprocessor supervises running status and gives diagnosis message. With a built-in safety barrier, the interface can directly match with intrinsically safe devices. • • • • • Operating Voltage: Bus Voltage: 24V Range Allowed: 16V 28V Power Voltage: 24VDC Range Allowed: 20VDC 28VDC Operating Current: Standby Current≤0.5mA Alarm Current≤500mA Programming mode: Electronic programming within 1-242, occupying one loop address. Wiring: Non-polarized two-bus with the controller; non-polarized twowire with DC24V power cable; polarized two-wire with explosionproof devices. Operating Temp: -10ºC to 50ºC Relative Humidity≤95%, no condensation Dimension: 200mm×162mm×85mm Weight: 1.5kg Mounting Hole Spacing: 192mm 212mm Material and Color of Enclosure: Q235A, grayish white Ingress Protection Level: IP33 Description Selection of compatible Control Panels I-8333 Interface can match with explosionproof sounder to form an intrinsically safe system. When fire occurs, the interface received alarm signal to fire alarm controller through loop and the controller will give alarm signal activate the alarm. When the interface itself is in fault, the controller will give fault signal and display the fault address of the interface. Compatible with all GST Intelligent Fire Alarm Panels. Ordering Information: Part No I-9333 Electronic addressing can be done through Handheld Programming tool (P-9910), purchased separately. E-MAIL: [email protected] Description Weight/ Kg Addressable Interface for Sounder including Zener Safety Barrier-Ex .180 Pack Qty per Box 120 MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intrinsically Safe Combined Detector C-9101Ex Technical Specifications • • • • • • • • Features and Benefits 2. 3. 4. 5. Multifunctional and highly reliable detector Sensing chamber for exceptional dust proof ability Twin LED for 360º vision Low profile design Initiated by fire alarm point using I-9332Ex Interface • • • Description C-9101 Explosion-proof Combination Heat/Photoelectric Smoke Detector is a kind of combination detector consisting of smoke sensing parts and semi-conductor heat sensing parts in technological structure and circuit structure. It’s applicable to zone 1 and zone 2 of areas with explosion-proof requirement in petroleum and chemical industries. It can match with fire alarm controller, explosion-proof addressable interface box, explosion-proof detector and terminal resistor produced by GST to conduct the processing of detector signals. E-MAIL: [email protected] Call Point Installation The detector should be installed complied with all local codes or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Code, BS5839, EN54.It is installed onto a standard one gang electrical box with a mounting hole that have 6.5cm spacing. Mounting Hole DZ- 03 Ex 1. Operating Voltage: DC24V, range allowed: DC12V~DC24V Operating Current: Standby Current≤60μA Alarming Current≤30mA Wiring: 1 pair Alarm Confirming LED: Red Heat Sensitivity: Class I Dimension: Diameter: 100mm, Height: 42mm (excluding the base) Safety Barrier Parameters: Uo=28VDC, Io=93mA Operating Environment: Temperature: -10ºC+40 ºC Relative Humidity:≤95%, no condensation Monitoring Area: When space height is 6m to 12m, the monitoring area of a detector is 80m2 for normal protection area; When space height is less than 6m, it is 60 m2. Enclosure Protection Level: IP22 Material and Color of Enclosure: ABS, ivory white A B HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intrinsically Safe Combined Detector C-9101Ex Wiring and Connection Safety Area Hazardous Area K1 K2 O2 I-9332 Interface Explosion-proof Detector Explosion-proof Detector O1 I1 Terminal Resistor I2 Explosion-proof Manual Call Point Explosion-proof Detector Sample wiring diagram above show detectors are connected with I-9333 Interface. There are four terminals with numbers on the explosion-proof orientation base, “1” is the anode input, “2” is the anode output, “3” is the power cathode, “4” is null. Selection of compatible Control Panels Compatible with all GST Intelligent Fire Alarm Panels via I-9332Ex Explosion Proof Interface (purchased separately) Ordering Information: Part No C-9101Ex DZB I-9332 E-MAIL: [email protected] Description Intrinsically Safe Combined Smoke and Heat Detector Intrinsically Safe Detector Base Interface Module Weight/Kg Pack Qty per Box 0.221 120 0.050 1.5Kg 360 1 MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intrinsically Safe Dual Heat Detector C-9103Ex Technical Specifications • • • • • • • • Features and Benefits 2. 3. 4. Fixed Temperature and Rate of Rise Detection Twin LED for 360º vision Low profile design Initiated by fire alarm point using I-9332Ex Interface Description C-9103 (Ex) Explosion-proof Rate of Rise and Fixed Temperature Heat Detector is applicable to Zone 1 and Zone 2 of areas with explosion-proof requirement in petroleum and chemical industries. It can match with LD-8332 Interface connected with GST fire alarm controller, explosion-proof detector to conduct the processing of detector signals. E-MAIL: [email protected] • Call Point Installation The detector should be installed complied with all local codes or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Code, BS5839, EN54.It is installed onto a standard one gang electrical box with a mounting hole that have 6.5cm spacing. Mounting Hole DZ- 03 Ex 1. • • Operating Voltage:DC12V to DC24V Operating Current: Standby Current≤60μA Alarming Current≤30mA Wiring: 1 Pair Alarm Confirming LED: Red, not lit when polling, constantly lit when alarming. Monitoring Area: 30 m2 for space height not more than 8m. Operating Environment: Temperature: -10ºC+40 ºC Relative Humidity: ≤95%, no condensation Dimension: Diameter: 100mm, Height: 45mm(excluding the base) Safety Barrier Parameters: U0=28V, I0=93mA Enclosure Protection Grade: IP53 Material and Color of Enclosure: ABS, ivory white Mounting Hole Distance: 45mm to 75mm A B HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intrinsically Safe Dual Heat Detector C-9103Ex Wiring and Connection Safety Area Hazardous Area K1 K2 O2 I-9332 Interface Explosion-proof Detector Explosion-proof Detector O1 I1 Terminal Resistor I2 Explosion-proof Manual Call Point Explosion-proof Detector Sample wiring diagram above show detectors are connected with I-9333 Interface. There are four terminals with numbers on the explosion-proof orientation base, “1” is the anode input, “2” is the anode output, “3” is the power cathode, “4” is null. Selection of compatible Control Panels Compatible with all GST Intelligent Fire Alarm Panels via I-9332Ex Explosion Proof Interface (purchased separately) Ordering Information: Part No C-9103Ex DZB I-9332 E-MAIL: [email protected] Description Weight/Kg Intrinsically Safe Dual Heat Detector Intrinsically Safe Detector Base Interface Module 0.220 0.050 1.5Kg Pack Qty per Box 120 360 1 MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intrinsically Safe Manual Call Point C-9201Ex Technical Specifications • • • • • • • • Features and Benefits 1. 2. 3. 4. • • LED indicator Two plug-in constructions allow easy installation. Utilized independent output contact Initiated by fire alarm point using I-9332Ex Interface • • • • Description C-9201(Ex) Explosion Proof Manual Call Point is designed for the purpose of raising an alarm manually once verification of a fire or emergency condition exists, by pressing the non breakable glass and alarm signal can be sent to the controller. After receiving the alarm signal, the controller will show the number of LD-8332 Interface connecting with the MCP, and vocalize alarm sound. This MCP is intrinsically safe type, is suitable in inflammable and hazardous places in petroleum and chemical industries. E-MAIL: [email protected] Operating Voltage: 24Vdc Operating Current: Standby Current: 0mA Alarming Current≤30mA Output Capacity: Rating DC60V/100mA passive output contact signal, contact resistance≤100mΩ Type of Initiating Part: Reusable Reset Mode: Manually resuming by a sucker LED indicator: Red, not lit when normal, lit after alarming. Explosion-proof Marking: ExibIICT6 Safety Barrier Output Parameters: Uo+28V, Io=93mA Wiring: 1 Pair Operating Environment: Temperature: -10ºC+50 ºC Relative Humidity: ≤95%, no condensation Mounting Hole Distance: 65mm Dimension: 90mm×122mm×48.5mm Degree of Protection of Enclosure: IP40 Material and Colour: ABS, red Call Point Installation The MCP should be installed complied with all local codes or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Code, BS5839, EN54.It is installed onto a standard one gang electrical box with a mounting hole that have 6.5cm spacing. HTTP://GSTRU.RU 65 HTTP://WWW.HOMBI.RU Intrinsically Safe Manual Call Point C-9201Ex Wiring and Connection Safety Area Hazardous Area K1 K2 O2 I-9332 Interface Explosion-proof Detector Explosion-proof Detector O1 I1 Terminal Resistor I2 Explosion-proof Manual Call Point Explosion-proof Detector Sample wiring diagram above show manual call point connected with I-9333 Interface. The terminals I1, I2: to intrinsically safe side of the Safety Barrier.; K1, K2: Normally open output terminals; while O2, O1: To next MCP. Selection of compatible Control Panels Compatible with all GST Intelligent Fire Alarm Panels via I-9332Ex Explosion Proof Interface (purchased separately) Ordering Information: Part No C-9201Ex I-9332 E-MAIL: [email protected] Description Intrinsically Safe Conventional Manual Call Point Interface Module Weight/Kg Pack Qty per Box 0.221 120 1.5Kg 1 MANUFACTURED IN ACCORDANCE WITH Note: Specifications are subject to change without notice. HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intrinsically Safe Conventional Sounder Strobe C-9403Ex/ C-9404Ex Description Features and Benefits 1. 2. 3. 4. High intensity and long life LED cluster High sound level and Low power consumption Initiated by fire alarm control panel Easy installation and connection The C-9403 (Ex) is an Intrinsically Safe conventional combined sounder and strobe while the C-9404 (Ex) is identical in appearance and features to the C-9404 (Ex) but without strobe element and are suitable used for petroleum and chemical industrial. This Using six highlights LED’s for high intensity visual alarm to warn the people especially the persons with hearing difficulties. The audio efficiency and sound distribution generate over 94 dB at 1 meters distance giving an excellent audibility from the device location. This conventional electronic wall mounted device initiated by fire alarm point using I9333Ex Interface (see manual for more information) with safety barrier to make an explosion proof system. Specification Part Number Protection rating Sound level output Main Sound Frequency Strobe / Frequency Explosion Proof Marking Tone Modification Period Operating voltage Operating current Operating Temperature Application Materials and colour Dimension Wiring E-MAIL: [email protected] C-9403Ex C-9404Ex IP 33 85 dB to 115 dB 2.8Khz 6 highlight LED; 1.4 Hz± 20% No feature Exib□CT6 0.7s ± 20% Power Supply 24Vdc(16~28Vdc) Supply current: standby 5mA / alarm current: standby 3mA / alarm 35mA 50mA -10°C to 50°C @ 95% relative humidity Indoor and outdoor use ABS / red; plexiglass / red Ø 110mm x 97.5 mm 2 wire (polarized) HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU Intrinsically Safe Conventional Sounder Strobe C-9403Ex/ C-9404Ex Sounder Installation The sounder base should be installed complied with all local codes or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Code, BS5839, EN54.It is installed onto a standard one gang electrical box with a mounting hole that have 6.5cm spacing. Selection of compatible ControPanels Compatible with all GST Intelligent Fire Alarm Panels via I-9333Ex Explosion Proof Interface (purchased separately) Ordering Information: Part No Description WALL ELECTRICAL BACK BOX C-9403Ex A hK MOUNTING BASE k ff H l C-9404Ex Wiring and Connection Sample wiring diagram below show sounder connected with I-9333 Interface. The sounder D1 (+) 9; D2 (-), is for 24VDC power supply polarized, connected to 3 and 4 of Interface. Each interface can only connect with one sounder Ex or sounder strobe Ex. Note that Interface should be installed in the safety area and the cable must be fire rated type and the size depends on the distance and application. Minimum size gauge 1.0mm²(18 AWG) Safety Area I-9333 Intrinsically Safe Conventional Sounder Strobe Intrinsically Safe Conventional Sounder Strobe Interface Module Weight /Kg Pack Qty per Box 0.350 45 0.340 45 1.5Kg 1 Hazardous Area I-9333 Ex-Interface I-9333Ex Circuit Board D1 D2 Z1 L+ 1(+) L- 2(-) 3(+) N F928 Zener Safety Barrier 4(-) Z2 24VDC Fire Alarm Control Panel E-MAIL: [email protected] Intrinsincally Safe Loop HTTP://GSTRU.RU HTTP://WWW.HOMBI.RU