Preview only show first 10 pages with watermark. For full document please download

Interface Relays

   EMBED


Share

Transcript

Industrial Relays Interface Relays Interface Relays Recommended application 100A peak 10 A 8A 6A 5A 2A Triac 300 mA 50 mA 10 mA 5 mA 1mA 1 2 C14-A10 C10-A14 CINT51 CINT61 1+1 CINT11 CINT21 CINT52 CINT62 CINT53 CINT63 C10-T13 C10-T12 CINT12 CINT22 CINT18 CINT28 Solid-State 100A peak & CINT15 CINT25 C12-A21 C12-A22 CHA1 twin contacts Interface modules Interface-Solide-State Modules AC 230VA DIN CINT1 CINT 2 Interface LABEL Relay module CINT-R1/ CINT-R2 MADE IN EC A1 V V A1 A1 A2 A2 With cage clamp terminals (1x 0,2 - 2,5 mm 2) CINT-21, -22, -25, -28 CINT-11, CINT-21 3600V Tamb. operation/storage: -20..+55/ - 40..+85°C MAX MIN 11 12 SOCKET 6,2 Interface Module Complete with integrated LED and switching module. 14 A2 6-24 6-24 With srcew terminals (0,2 - 2,5 mm 2) CINT-11, -12, -15, -18 Test voltage: Solid-State module CINT-R5 / CINT-R8 (+) MODULE MODULE SOCKET A2 RELAY RELAY NC LABEL CINT1/ UC6-24VU 14 Max. 6A 250V (see module) COMAT SOCKET 11 14 12 11 11 RELAY A2(–) COIL A1(+) A1 RELAY CINT12/UC24V 01 CINT-R2/ UC24VU AVING SPACE S 12 11 (+) 14 NO OUT 01 14 COM 12 12 CINT-12, CINT-22 CINT-15, CINT-25 CINT-18, CINT-28 Interface Module Interface Module Interface Module Interface Module for PLC’s and process control. High power contact AgSnO2. With screw terminals (CINT-11) or cage clamp terminals (CINT-21). for PLC’s and process control. Signal contact AgNi +5µ Au. With screw terminals (CINT-12) or cage clamp terminals (CINT-22). for PLC`s and process control. DC solid-state switch NO, pnp. Integrated transient clamp circuit. For fast and high frequency switching. With screw terminals (CINT-15) or cage clamp terminals (CINT-25). for PLC`s and process control. AC solid-state switch type NO synchronous switching triac. For fast and high frequency switching. With screw terminals (CINT-18) or cage clamp terminals (CINT-28). 6 A 250 V A 6 A 250 V A 2 A 24 V D 2 A 250 V A 10mA 12V 1mA 1V 1mA 6V 10mA 12V Data at Tamb. =20°C (standard coil) Contact material Switching power AC1 Switching power DC1 Switching power AC15 Peak inrush current Switching cycles: mechanical/electrical Contact resistance/voltage drop AgSnO 2 1500VA ...250W 300VA/230V 100A/2,5ms 10x106 /105 <100m Operation voltage AC50/60Hz / DC Power consumption Pmax. 24V Power consumption Pmax. AC230V On delay/release time Parallel circuit 0,8...1,2UN 0,7...1,25Un 0,8...1,2UN 240mW 240mW 240mW – 1,1W 1,1W <1ms 5ms/10ms 5ms/10ms All modules have an internal parallel diode circuit; green LED status indication. CINT-R1/UC110-240V CINT-R1/UC24V CINT-R2/UC110-240V CINT-R2/UC24V Connector bridge CINT-BR20 12 CINT-R8/DC24V 11 47.0 With srcew terminals (packing unit: 2x 10pin) A1 A1 A2 A2 6,2 With cage clamp terminals 44,3 41,5 TS 35 Marking label (supplied with standard delivery) CINT-BEZ 12 14 Connector bridge CINT-BR20 (packing unit: 64 pieces) CINT-R5/DC24V 11 Accessories/Sparte parts Marking label CINT-BEZ CINT-18/DC24V CINT-28/DC24V 14 88,5 Module d’interface CINT-21/UC24V CINT-15/DC24V CINT-25/DC24V TS 35 10% Ordering example 0,7...1,25Un 240mW – <1ms 24, 230 CINT-12/UC.....V CINT-22/UC.....V DC Replacement Switching modules Solid-state (Triac) 500VA – – 20A/10ms – <1,5V 49,2 50/60 Hz / 24, 230 CINT-11/UC.....V CINT-21/UC.....V Solid-state – ...60W – 20A/10ms – <100m /200mV 93,5 UC AgNi + 5µ Au 1500VA ...250W – 10A/20ms 10x106 /105 <100m 3,4 73 6,2 3,4 73 Interface Modules DIN CINT5 CINT 6 Interface RELAY Relay module CINT-51/61 RELAY CINT-52/62 CINT-53/63 A1 12 11 14 22 21 24 A2 SOCKET With srcew terminals (0,5 -2,5 mm 2) CINT-51, -52, -53 With cage clamp terminals (1x 0,5 -2,5 mm 2) CINT-61, -62, -63 CINT-51, CINT-61 Interface Module Complete with integrated LED and relay.ul. Test voltage: 3600V Isolation / // / : 4000Vrms // 2000Vrms Tamb. operation/storage: -20..+55/ - 40..+85°C MAX MIN CINT-52, CINT-62 CINT- 53, CINT- 63 Interface Module Interface Module Interface Module for PLC’s and process control. 1 x CO high power contact AgSnO2. With screw terminals (CINT-51) or cage clamp terminals (CINT-61). With LED output status display. for PLC’s and process control. 1x CO signal contact AgNi+5µ Au. With screw terminals (CINT-52) or cage clamp terminals (CINT-62). With LED output status display. for PLC`s and process control. 1x CO signal contact AgNi for standard applications. With screw terminals (CINT-53) or cage clamp terminals (CINT-63). With LED output status display. 10 A (13 A) 250 V A 8 A 250 V A 8 A 250 V A 50mA 24V 1mA 12V 10mA 24V Data at Tamb. =20°C (standard coil) Contact material Switching power AC1 Switching power DC1 Switching power AC15 Peak inrush current Switching cycles: mechanical/electrical Contact resistance AgSnO 2 2500VA ...300W 300VA /230V 100A /5ms 10x106 /105 <100m Operation voltage AC50/60Hz / DC Power consumption Pmax. 24V Power consumption Pmax. AC230V On delay/release time Parallel circuit 0,8...1,2UN 0,8...1,2UN 0,8...1,2UN 480mW 480mW 480mW 1,1W 1,1W 1,1W 5ms /10ms 5ms/10ms 5ms/10ms All modules have an internal parallel diode circuit; green LED status indication. UC 50/60 Hz / Replacement relay modules AgNi + 5µ Au 2000VA ...250W – 15A /20ms 10x106 /105 <100m 24, 230 CINT-51/ UC.....V CINT-61/ UC.....V 24, 230 CINT-52 / UC.....V CINT-62 / UC.....V 24, 230 CINT-53 / UC.....V CINT-63 / UC.....V CINT-R21/UC110-240V CINT-R21/UC24V CINT-R22/UC110-240V CINT-R22/UC24V CINT-R23/UC110-240V CINT-R23/UC24V Connector bridge CINT-BR8 22 NC 12 Ordering example Ag Ni 2000VA ...250W – 15A/20ms 10x106 /105 <100m Marking label (supplied with standard delivery) CINT5-BEZ 22 NC 12 21 COM 11 21 COM 11 Marking label CINT5-BEZ /18 (packing unit: 1x 18pieces) TS 35 93 48,5 91 RELAYS With cage clamp terminals With srcew terminals 220-240 VU 220-240 VU A1 A1 A2 A2 14 3,4 72 14 45 (packing unit: 1x 5 pieces) TS 35 Connector bridge CINT-BR8/5 42,5 Accessories/Spare parts RELAYS Interface module CINT-51/UC24V 48 24 NO 14 24 NO 14 3,4 72 AUTO - ON - OFF Relay DIN CHA1 Interface UR PLC FOR YO A1 A2 24V AC/DC B1 B2 24 V 300 mA B1 CHA1 / UC 24 VU 24V AC/DC B1 A1(+) B2 A2(–) ON OFF AUTO A2(–) S ON 24V 300mA AUT OFF S A1(+) B2 01 A3 11 12 14 10A 250V MADE IN EC-01 10A 250 VA ON 01 A3 11 12 14 10A 250V 11 A3 12 14 CHA1 Interface Module Complet with hand switch and LED for AUTO position indication. Test voltage: 3000V Tamb. operation/storage: -10..+50/ - 40..+85°C MAX MIN Data at Tamb. =20°C (standard coil) Interface Module for control systems with 1x CO high power contact, 1x NO signal contact 300mA. Installation: 45mm front dimension. Front setting: AUTO-ON-OFF for maintenance and emergency operation 10 A 250 V A 10mA 12V Power contact Signal contact Contact material Switching current /voltage Switching power AC1 Switching power AC15 Switching power DC1 Peak inrush current Mechanical switching cycles Contact resistance AgCdO 10A 250V 2500VA 500VA/230V ...250W 100A 2,5ms 10x106 <100m Ag 300mA /30V 10VA 10W 0,5A 103 <100m Operation voltage AC50/60Hz Operation voltage DC Power consumption Pmax 0,8..1,2UN 1,1UN (10A) 400mW/24V –– –– –– UC 50/60 Hz / CHA1/UC24V Marking label (supplied with standard delivery) CHA-BEZ/10 A1 A2 45 Ordering example Interface module CHA1/UC24V Marking label CINT5-BEZ /18 (packing unit: 1x 18pieces) 11 A3 12 14 17 26,5 11,5 4 58 62 TS35 84 B1 B2 ON OFF AUTO ! Kühn Controls AG Notes: You want more information about this product, please call us: tel: +49 (0)7082-940000 or send us a fax: +49 (0)7082-940001, or email: [email protected] or visit our Website: www.kuehn-controls.de