Preview only show first 10 pages with watermark. For full document please download

Interface Technology Im Modular Housings

   EMBED


Share

Transcript

9 10 – 1 + 11 12 – 2 + 13 + 3 – 14 15 16 NO 2 3 Isolating Switching Amplifier MS13-33Ex0-T 3-channel MS13-33Ex0-T Power Switching status 1 Power 1 2 • 3-channel isolating switching amplifier • Intrinsically safe input circuits EEx ia • Area of application according to ATEX: II (1) GD, I (M1) • Galvanic isolation between input circuits, output circuits and supply voltage • 3 isolated transistor outputs, short-circuit and reverse polarity protected 3 4 5 6 1 7 8 The MS13-33Ex0-T switching amplifier is a 3-channel device with intrinsically safe input circuits. They can be connected to sensors according to EN 60947-5-6 (NAMUR), variable resistors or potentialfree contacts. Each output circuit is provided with one isolated, short-circuit and reverse polarity protected transistor output. The green LED on the front cover indicates that the devices are powered. The yellow LEDs indicate the switching status of the outputs. The selected output mode applies to all three channels. Program for normally closed mode (NC/R) by leaving terminals 15/16 open and for normally open mode (NO/A) by linking terminals 15/16. When mechanical contacts are used as input devices, resistors (II) must be added to the contacts. This will prevent the monitoring control circuit from recognising the mechanical contacts as a wirebreak or short-circuit. The input circuits are individually monitored for wire-break and short-circuit. The affected output turns off during an input fault (green LED off). • Input circuit monitoring for wire-break and short-circuit • Selectable NO/NC output function • Universal supply voltage (20..250 VAC/20...125 VDC) II I 16 A/R 3 2 15 16 A/R 14 14 – 13 13 + NAMUR 12 12 + 11 11 – NAMUR 10 1 9 10 + NAMUR 9 8 3 15 YE – + 2 YE – + 1 +8 V YE – – 3 7 6 £ 30 VDC 2 £ 50 mA 5 4 1 3 2 GN 1 Power Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 1 – 101 /0304 Isolating Switching Amplifier MS13-33Ex0-T Type Ident-no. MS13-33Ex0-T 5433201 Supply voltage U B Line frequency (AC) Power consumption Galvanic isolation 20...250 VAC/20...125 VDC 40...70 Hz ≤3W between input circuit, output circuit and supply voltage for 250 Vrms test voltage 2.5 kVrms Input circuits Operating characteristics – Voltage – Current Switching threshold Hysteresis Wire-break threshold Short-circuit threshold acc. to EN 60947-5-6 (NAMUR), intrinsically safe according to EN 50020 8V 4.5 mA 1.55 mA 0.2 mA ≤ 0.1 mA Ra approx. 200 Ω Contact configuration Of mechanical switches with active input circuit monitoring function 1...2,2 kW resistor module WM1, ident-no. 0912101 10...22 kW Output circuits Switching voltage Switching current Voltage drop Switching frequency 3 transistor outputs, potential-free, short-circuit and reverse polarity protected ≤ 30 VDC ≤ 50 mA ≤ 2.5 V ≤ 2 kHz Ex-approval acc. to certificate of conformity Maximum nominal values – No load voltage U0 – Short-circuit current I0 – Power P0 – Safety voltage U m Max. external inductances/capacitances L0/C 0 – [EEx ia] IIC – [EEx ia] IIB – [EEx ia] I Marking of device 1 mH/500 nF 3 mH/2500 nF 10 mH/10 µF II (1) GD [EEx ia] IIC LED indications – Power – Switching status green 3 x yellow Housing Mounting Connection Connection profile Degree of protection (IEC 60529/EN 60529) Operating temperature DMT 01 ATEX E 119 11.0 V 55 mA 150 mW 250 VAC/125VDC I (M1) [EEx ia] I 50 mm wide, Polycarbonate/ABS panel mounting or snap-on clamps for top-hat rail (DIN 50022) 2 x 8 self-lifting pressure plates ≤ 2 x 2.5 mm2 or 2 x 1.5 mm2 with wire sleeves IP20 -25…+60 °C 75 110 50 1 – 102 /0304 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com