Preview only show first 10 pages with watermark. For full document please download

Intrinsically Safe Digital Multimeter Model Mx 57ex

   EMBED


Share

Transcript

Intrinsically Safe Digital Multimeter Model MX 57EX The AEMC® Model MX 57EX is an intrinsically safe digital multimeter designed for use in dangerous or explosive atmospheres. This meter is considered as a passive device without inductive or capacitive issues that are problematic in dangerous or explosive environments. This meter provides high functionality in a unique case designed for enhanced safety, reliability, ease-of-maintenance and protection from contaminants. The meter is built into a rugged housing which provides a separate battery and fuse compartment to isolate the DMM’s electronics from contamination. This meter offers a complete set of measurement ranges and is in compliance with international safety and quality standards to ensure a professional and reliable measuring tool. The Model MX 57EX measures AC Amps, AC Volts, DC Amps, DC Volts, Resistance, Continuity (with beeper) and has a Diode Test function. 34-segment analog bargraph for easy trend readings. Accuracy is 0.025%. The meter is equipped with a Data Hold function that freezes the measurement for later viewing. Includes a pair of test leads (red/ black), 9V Alkaline battery, hard carrying case and a user manual. The large and easy-to-read LCD features a 50,000-count digital display. The display features comprehensive user interface symbols, such as low battery, Min/Max/Avg and a Digital Multimeter Model MX 57EX (pdf) Technical Assistance (800) 343-1391 Rev. 05 www.aemc.com 02/07 1 of 5 Features Applications • ATEX 6005X, II 2 G/D EEx ib IICT6 or I M2 EEx ib I assigned specifications • Oil refineries • Mining • Pharmaceutical plants • Logic signal measurement and ADP input • MIN/MAX/AVG functions • Bargraph with zoom (x5) and center zero • Rugged design — IP67 185°F (85°C) rating • Protection by 500mA intrinsic safety fuse for the current range Construction Model MX 57EX used outdoors in a mine. 21 1 20 19 3 5 18 17 16 15 14 4 6 7 8 9 13 11. Time functions selection 12. Monitoring values selection/display 13. Display backlighting 14. Display hold 15. Peak measurement 16. Power off 17. AC voltage measurement 18. 500mV voltage measurement 19. DC voltage measurement 2 12 11 10. Input terminal range 10A 11. Input terminal range µA, mA 12. Multimeter reference input 13. Input terminal, ranges 11, 12, 13, 14 and 15 14. Resistance measurement 15. Capacitance measurement 16. Temperature measurement 17. Current measurement up to 500mA 18. Range change 19. Data sending to a printer 20. Power on (selects secondary functions) 21. Bargraph scale magnification Digital Multimeter Model MX 57EX (pdf) Technical Assistance (800) 343-1391 Rev. 05 www.aemc.com 02/07 2 of 5 Specifications Meets the EN 50014 and EN 50020 standards, II 2 G/D EEx ib IICT6 or I M2 EEx ib I assigned specifications, IP 67 185°F (85°C) (electrical equipment for use in explosive atmospheres). CE certificate: LCIE 02 ATEX 6005X. Quality certificate: LCIE 02 ATEX Q8021. MODEL MX 57EX AC CURRENT Measurement Range Resolution Bandwidth Accuracy 500µ A 10nA DC to 5kHz ±0.75% of Reading ± 30cts 600Vrms Overload Protection AC VOLTAGE Measurement Range Resolution Bandwidth Accuracy 500mV 10µV 40Hz to 1kHz ±0.3% of Reading ± 30cts 11MΩ 1100Vpk Input Impedance Overload Protection DC CURRENT Measurement Range Resolution Accuracy 5mA 100nA DC to 5kHz ±0.6% of Reading ± 30cts 600Vrms 5V 100µV 1kHz to 4kHz 1% of Reading ± 30cts 11MΩ 1100Vpk 500µ A 10nA ±0.2% of Reading ± 5cts 600Vrms Overload Protection DC VOLTAGE Measurement Range Resolution Accuracy 500mV 10µV ±0.025% of Reading ± 2cts 11MΩ 1100Vpk Input Impedance Overload Protection RESISTANCE Measurement Range Resolution Accuracy Max Open-Circuit Voltage Overload Protection CONTINUITY Measurement Range Response Time DIODE Test Voltage Test Current CAPACITANCE Range Accuracy FREQUENCY Measurement Range Accuracy TEMPERATURE Range (User selectable in °F or °C) Sensor GENERAL Digital Display Analog Bargraph Power Source Dimensions Weight ENVIRONMENTAL Operating Temperature Storage Temperature SAFETY Safety Rating Agency Approval EMC 500Ω 10mΩ ±0.07% of Reading ± 5cts 7V 600Vrms 50mA 1µA DC to 5kHz ±0.6% of Reading ± 30cts 600Vrms 50V 1mV 4kHz to 10kHz 2% of Reading ± 30cts 10MΩ 1100Vpk 5mA 100nA ±0.2% of Reading ± 2cts 600Vrms 5V 100µV ±0.025% of Reading ± 2cts 11MΩ 1100Vpk 5kΩ 100mΩ ±0.07% of Reading ± 2cts 7V 600Vrms 500mA 10µA DC to 5kHz ±0.7% of Reading ± 30cts 600Vrms 500V* 10mV 10kHz to 30kHz 2% of Reading ± 30cts 10MΩ 1100Vpk 50mA 1µA ±0.05% of Reading ± 2cts 600Vrms 50V 1mV ±0.025% of Reading ± 2cts 10MΩ 1100Vpk 50kΩ 1Ω ±0.07% of Reading ± 2cts 7V 600Vrms 750V* 100mV 30kHz to 50kHz ±3% of Reading ± 30cts 10MΩ 1100Vpk 500mA 10µA ±0.2% of Reading ± 2cts 600Vrms 500V* 10mV ±0.025% of Reading ± 2cts 10MΩ 1100Vpk 500kΩ 10Ω ±0.07% of Reading ± 2cts 7V 600Vrms 5MΩ 100Ω ±0.3% of Reading ± 2cts 7V 600Vrms 1000V* 100mV ±0.2% of Reading ± 2cts 10MΩ 1100Vpk 50MΩ 1kΩ ±1% of Reading ± 2cts 7V 600Vrms 10Ω to 20Ω 1ms 0 to 2V 1mA ± 20% 50nF to 50mF 1% of Reading ± 2cts 0.62Hz to 500kHz 0.03% of Reading ± 2cts -328° to 1472°F (-200° to 800°C) PT100/PT1000 50,000-count 34-segment 9V Alkaline battery 7.4 x 3.2 x 1.5" (189 x 82 x 40mm) 0.8 lb (400g) 14° to 104°F (-10° to 40°C) -40° to 158°F (-40° to 70°C) EN 50014, EN50020 II 2 G/D EEx ib IICT6 or I M2 EEx ib I assigned specifications Emission and immunity as per NF EN 61326-1, 1998 CE Mark Yes *Operating voltages are limited to 60V peak value or currents to 500mA for intrinsically safe operation. Digital Multimeter Model MX 57EX (pdf) Technical Assistance (800) 343-1391 Rev. 05 www.aemc.com 02/07 3 of 5 Case included with MX 57EX ORDERING INFORMATION CATALOG NO. DMM MX 57EX (Intrinsically Safe, TRMS, 50,000-count, 0.1% Accuracy). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . Cat. #2130.65 Digital Multimeter Model MX 57EX (pdf) Technical Assistance (800) 343-1391 Rev. 05 www.aemc.com 02/07 4 of 5 Contact Us United States & Canada: Chauvin Arnoux®, Inc. d.b.a. AEMC ® Instruments 200 Foxborough Blvd. Foxborough, MA 02035 USA (508) 698-2115 • Fax (508) 698-2118 www.aemc.com Customer Support – for placing an order, obtaining price & delivery: [email protected] Sales Department – for general sales information: [email protected] Repair and Calibration Service – for information on repair & calibration, obtaining a user manual: [email protected] Technical and Product Application Support – for technical and application support: [email protected] Webmaster – for information regarding www.aemc.com: [email protected] South America, Central America, Mexico, Caribbean, Australia & New Zealand: Chauvin Arnoux®, Inc. d.b.a. AEMC ® Instruments 15 Faraday Drive Dover, NH 03820 USA (978) 526-7667 • Fax (978) 526-7605 [email protected] www.aemc.com All other countries: Chauvin Arnoux SCA 190, rue Championnet 75876 Paris Cedex 18, France 33 1 44 85 45 28 • Fax 33 1 46 27 73 89 [email protected] www.chauvin-arnoux.com Digital Multimeter Model MX 57EX (pdf) Technical Assistance (800) 343-1391 Rev. 05 www.aemc.com 02/07 5 of 5