Preview only show first 10 pages with watermark. For full document please download

Inverter Single Wall

   EMBED


Share

Transcript

Inverter Single Wall-mounted THE EXPERTS IN ROOM AIR CONDITIONING FAC P/no : 960-942-07 Inverter Single Inverter Single-60Hz(R410A) 1. Models Line Up 2. Nomenclature 3. Specifications 4. Function List 5. Dimensional Drawings 6. Wiring Diagrams 7. Refrigerant Cycle Diagrams 8. Capacity Tables 9. Capacity Coefficient Factor 10. Electric Characteristics 11. Operation Range 12. Air Flow and Temperature Distributions (Reference Data) 13. Sound Levels (Reference Data) 14. Remote Controller 15. Installation Inverter Single Test Condition of International Standard Cooling Capacity Heating Capacity Maximum Cooling Operating Maximum Heating Operating Enclosure Sweat / Condensate Disposal Freeze-up / Low Temperature Indoor Outdoor Indoor Outdoor Indoor Outdoor Indoor Outdoor Indoor Outdoor Indoor Outdoor DB°C(°F) WB°C(°F) DB°C(°F) WB°C(°F) DB°C(°F) WB°C(°F) DB°C(°F) WB°C(°F) DB°C(°F) WB°C(°F) DB°C(°F) WB°C(°F) DB°C(°F) WB°C(°F) DB°C(°F) WB°C(°F) DB°C(°F) WB°C(°F) DB°C(°F) WB°C(°F) DB°C(°F) WB°C(°F) DB°C(°F) WB°C(°F) 27.0 19.0 35.0 24.0 20.0 15.0 7.0 6.0 32.0 23.0 43.0 26.0 27.0 15.0 21.0 15.0 27.0 24.0 27.0 24.0 21.0 15.0 21.0 15.0 ISO 5151 T1 27.0 19.0 35.0 24.0 20.0 15.0 7.0 6.0 32.0 23.0 43.0 26.0 27.0 24.0 18.0 27.0 24.0 27.0 24.0 21.0 15.0 21.0 - T3 29.0 19.0 46.0 24.0 20.0 15.0 7.0 6.0 32.0 13.0 52.0 31.0 27.0 24.0 18.0 27.0 24.0 27.0 24.0 21.0 15.0 21.0 - KS : Korea Standard ISO : International Standard Organization AHRI : Air-Conditioning, Heating, and Refrigeration Institute AHAM : Association of Home Appliance Manufacturers AS/NZS : Australia and New Zealand Standard SASO : Saudi Arabian Standards Organization AHAM AHRI AS/NZS (Window 210/240 3823.1 AC) 26.7 (80) 19.4 (67) 35.0 (95) 23.9 (75) 21.1 (70) 15.6 (60) 8.3 (47) 6.1 (43) 26.7 (80) 19.4 (67) 46.11 (115) 23.9 (75) 26.7 (80) 23.9 (75) 18.3 (65) 26.7 (80) 23.9 (75) 26.7 (80) 23.9 (75) 19.4 (67) 13.9 (57) 19.4 (67) 13.9 (57) 26.7 (80) 19.4 (67) 35.0 (95) 23.9 (75) 21.1 (70) 15.6 (60) 8.3 (47) 6.1 (43) 32.2 (90) 22.8 (73) 43.3 (110) 25.6 (78) 26.7 (80) 22.8 (73) 23.9 (75) 18.3 (65) 26.7 (80) 23.9 (75) 26.7 (80) 23.9 (75) 21.1 (70) 15.6 (60) 21.1 (70) 15.6 (60) 27.0 19.0 35.0 24.0 20.0 15.0 7.0 6.0 32.0 23.0 43.0 26.0 27.0 24.0 18.0 27.0 24.0 27.0 24.0 21.0 15.0 21.0 - SASO 2681 T1 27.0 19.0 35.0 24.0 20.0 15.0 7.0 6.0 32.0 23.0 43.0 26.0 27.0 24.0 18.0 27.0 24.0 27.0 24.0 21.0 15.0 21.0 - T3 29.0 19.0 46.0 24.0 20.0 15.0 7.0 6.0 32.0 13.0 52.0 31.0 27.0 24.0 18.0 27.0 24.0 27.0 24.0 21.0 15.0 21.0 - Inverter Single CLASSIFICATION KSC 9306 Inverter Single 1. Models Line Up 1.1 Indoor Unit Inverter Single Model Name Nominal Capacity [kW (kBtu/h)] Category Picture Chassis 2.64 (9) 3.11 (12) 3.28 (12) 3.51 (12) 4.98 (18) 6.45 (24) MW24C3J Cooling Inverter SB / SC MW09C1J MW12C1J MW18C3J Heat Pump Inverter SB / SC MW09Y3J MW12Y3J MW18Y3J High SEER SM Long Pipe SV 1 _ Wall Mounted-60Hz(R410A) 8.79 (30) 9.67 (36) MW30Y3J MW36Y3J MWH12Y3J MW24Y3J Inverter Single 1. Models Line Up 1.2 Outdoor Unit Model Name 1Ø, 115 V, 60 Hz 1Ø, 208/230 V, 60 Hz Picture Chassis 2.64 (9) 3.11 (12) 3.28 (12) 3.51 (12) UL2 MR09C1J MR12C1J UL2 MR09Y3J MR12Y3J UE UE1+ MRH12Y3J 4.98 (18) 6.45 (24) 8.79 (30) 9.67 (36) MR24C3J MR24Y3J MR30Y3J MR36Y3J MR18C3J MR18Y3J Wall Mounted-60Hz(R410A) _ 2 Inverter Single Power Supply Nominal Capacity [kW (kBtu/h)] Inverter Single 2. Nomenclature W 09 C 1 Inverter Single M J Marketing Model (Internal Use) Voltage 1 = 115V/60hz/1 3 = 230V/60hz/1 Refrigeration Cycle C = Cool Only Y = Heat Pump Capacity 9 = 9,000 BTU/h 12 = 12,000 BTU/h 18 = 18,000 BTU/h 24 = 24000 BTU/h 30 = 30,000 BTU/h 36 = 36,000 BTU/h Model Type W= Wall mounted R= Outdoor component WH= Wall mounted High SEER RH= Outdoor high SEER Series Mini-split 3 _ Wall Mounted-60Hz(R410A) Inverter Single 3. Specifications System FAC Model Name Outdoor Unit Indoor Unit M12CJ M18CJ M24CJ MR12C1 J MR18C3J MR24C3J MW24C3J MW09C1J MW12C1J MW18C3J kW 2.638 3.106 4.982 6.448 Btu/h. 9000 10600 17000 22000 Power Input Cooling W 677 815 1417 2040 Running Current Cooling A 6 7.3 6.3 9.0 Starting Current Cooling A 6 7.3 6.3 9.0 Cooling COP - 3.90 3.81 3.52 3.16 EER - 13.3 13.0 12.0 10.8 SEER - 21.5 21.5 18.0 20.0 Power Supply Ø, V, Hz 1, 115, 60 1, 115, 60 1, 208/203, 60 1, 208/203, 60 Power Factor % 98 97 97 98 Indoor (QUIET, LOW, MED, HIGH) m3/min(CFM) 3.5(124)/6.0(212)/ 7.7(272)/9.5(335) 3.5(124)/6.0(212)/ 7.7(272)/9.5(335) 8.5(300)/11(389)/ 14.5(512)/17.0(600) 8.5(300)/11(389)/ 14.5(512)/17.0(600) Outdoor,Max m3/min(CFM) 33(1,165) 33(1,165) 50(1,766) 60(2,119) l/h. 1.1 1.3 2 2.6 Indoor,H/M/L/Sleep dB(A)+3 39 / 33 / 24 / 19 39 / 33 / 24 / 19 45 / 40 / 35 / 29 46 / 40 / 35 / 29 Outdoor,Max dB(A)+3 45 45 53 54 g(oz) R410A, 1,000(35.3) R410A, 1,000(35.3) R410A, 1,350(47.6) R410A, 1,800(63.5) Air Flow Rate Moisture Removal Sound Level Refrigerant & Charge (at 7.5 m/24.6ft) Additional Refrigerant charge Compressor 20(0.22) 20(0.22) 20(0.22) 35(0.38) Type g/m(oz/ft) Single Rotary Single Rotary Twin Rotary Twin Rotary Model GA102MFB GA102MFB GKT141MB GJT240MBA BLDC BLDC BLDC BLDC PVE(FVC68D) PVE(FVC68D) PVE(FVC68D) PVE(FVC68D) 310 310 470 900 - - - - Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan Motor Type Oil Type Oil Charge cc O.L.P. name Type Fan(Indoor) Motor Output W Type 20 30 30 Propeller Propeller Propeller BLDC BLDC BLDC BLDC W 43 43 85 124 A 20 20 20 30 Power Supply Cable No.*mm2 (AWG) 3*2.0(14) 3*2.0(14) 3*2.0(14) 3*2.5(12) Power and Transmission Cable No.*mm2 (AWG) 4*1.0(18) 4*1.0(18) 4*1.0(18) 4*1.0(18) Liquid Side mm(in) 6.35(1/4) 6.35(1/4) 6.35(1/4) 9.52(3/8) Gas Side mm(in) 9.52(3/8) 9.52(3/8) 12.7(1/2) 15.88(5/8) mm(in) 21.5 / 16.0(0.85 / 0.63) 21.5 / 16.0(0.85 / 0.63) 21.5 / 16.0(0.85 / 0.63) 21.5 / 16.0(0.85 / 0.63) mm 885*285*210 885*285*210 1,030*325*245 1,030*325*245 inch 35.2*11.2*8.3 35.2*11.2*8.3 40.6*12.8*9.64 40.6*12.8*9.64 mm 770*545*288 770*545*288 870*655*320 870*800*320 inch 30.3*21.5*11.3 30.3*21.5*11.3 34.3*25.8*12.6 34.3*31.5*12.6 Indoor kg(lbs) 10.2(22.5) 10.2(22.5) 14.5(31.96) 14.5(31.96) Outdoor kg(lbs) 34(75) 34(75) 44(97) 55(121.25) Indoor kg(lbs) 12.4(27.3) 12.4(27.3) 18.2(40.1) 18.2(40.1) Outdoor kg(lbs) 35.8(78.9) 35.8(78.9) 46(101.4) 58.5(128.97) Cooling(Outdoor) °C(℉)DB -10(-18)*~48 [14.0(0)*~118.4] -10(-18)*~48 [14.0(0)*~118.4] -10(-18)*~48 [14.0(0)*~118.4] -10(-18)*~48 [14.0(0)*~118.4] Heating(Outdoor) °C(℉)WB - - - - Piping Length (Min/Max) m(ft) 2(6.6) / 20(65.6) 2(6.6) / 20(65.6) 3(9.84) / 20(65.6) 3(9.84) / 30(98.4) Chargeless m(ft) 12.5(41.0) 12.5(41.0) 7.5(24.6) 7.5(24.6) Max. Elevation Difference m(ft) 10(32.8) 10(32.8) 10(32.8) 15(49.2) SB / UL2 SB / UL2 SC / UE SC / UE1+ Fan(Outdoor) Motor Type 20 Propeller Motor Output Circuit Breaker Piping Connections Drain Hose(O.D / I.D.) Indoor (W*H*D) Dimensions Outdoor (W*H*D) Net Weight Gross Weight Operation Range Tool Code(Chassis) Indoor / Outdoor Note O : Applied, X : Not applied, – : No relation • Filters are optional in some specific areas. • For Circuit Breaker Rating, please conform to local standards whenever necessary. • * : With wind baffle installed, the minimum temperature will be 0℉ D.B. in cooling. Wall Mounted-60Hz(R410A) _ 4 Inverter Single Cooling Capacity M09CJ MR09C1J Inverter Single 3. Specifications System FAC Model Name Outdoor Unit Inverter Single Indoor Unit Cooling Capacity Heating Capacity M09YJ M12YJ M18YJ MR09Y3J MR12Y3J MR18Y3J MW18Y3J MW09Y3J MW12Y3J kW 2.638 3.282 4.982 Btu/h. 9,000 11,200 17,000 kW 3.165 3.898 5.92 Btu/h. 10,800 13,300 20,200 Power Input Cooling/Heating W 677/700 896/1,000 1417/ 1680 Running Current Cooling/Heating A 3/3.7 4.2/4.9 6.3/7.3 Starting Current Cooling/Heating A 3/3.7 4.2/4.9 6.3/7.3 Cooling COP - 3.90 3.66 3.52 EER - 13.3 12.5 12 SEER - 21.5 21.5 18 HSPF - 11 11 9.7 Power Supply Ø, V, Hz 1, 208/230, 60 1, 208/230, 60 1, 208/230, 60 Power Factor % 94 97 97 Indoor (QUIET, LOW, MED, HIGH) m /min(CFM) 3.5(124)/6.0(212)/ 7.7(272)/9.5(335) 3.5(124)/6.0(212)/ 7.7(272)/9.5(335) 8.5(300)/11(389)/ 14.5(512)/17.0(600) Outdoor,Max m3/min(CFM) 33(1,165) 33(1,165) 50(1,766) l/h. 1.1 1.3 2 Indoor,H/M/L/Sleep dB(A)+3 39 / 33 / 24 / 19 39 / 33 / 24 / 19 45 / 40 / 35 / 29 Outdoor,Max dB(A)+3 45 45 53 g(oz) R410A, 1,000(35.3) R410A, 1,000(35.3) R410A, 1,350(47.6) Air Flow Rate Moisture Removal Sound Level Refrigerant & Charge (at 7.5 m/24.6ft) Additional Refrigerant charge Compressor 3 20(0.22) 20(0.22) 20(0.22) Type g/m(oz/ft) Single Rotary Single Rotary Twin Rotary Model GA102MFB GA102MFB GKT141MB BLDC BLDC BLDC PVE(FVC68D) PVE(FVC68D) PVE(FVC68D) 310 310 470 - - - Cross Flow Fan Cross Flow Fan Cross Flow Fan Motor Type Oil Type Oil Charge cc O.L.P. name Type Fan(Indoor) Motor Output W Type Fan(Outdoor) Motor Output Power Supply Cable BLDC BLDC 43 43 85 A 15 15 20 No.*mm2 (AWG) 3*1.0(18) 3*1.0(18) 3*2.0(14) 4*1.0(18) 4*1.0(18) 4*1.0(18) mm(in) 6.35(1/4) 6.35(1/4) 6.35(1/4) Gas Side mm(in) 9.52(3/8) 9.52(3/8) 12.7(1/2) mm(in) 21.5 / 16.0(0.85 / 0.63) 21.5 / 16.0(0.85 / 0.63) 21.5 / 16.0(0.85 / 0.63) mm 885*285*210 885*285*210 1,030*325*245 inch 35.2*11.2*8.3 35.2*11.2*8.3 40.6*12.8*9.64 mm 770*545*288 770*545*288 870*655*320 inch 30.3*21.5*11.3 30.3*21.5*11.3 34.3*25.8*12.6 Indoor kg(lbs) 10.2(22.5) 10.2(22.5) 14.5(31.96) Outdoor kg(lbs) 34(75) 34(75) 44(97) Indoor kg(lbs) 12.4(27.3) 12.4(27.3) 18.2(40.1) Indoor (W*H*D) Dimensions Outdoor (W*H*D) Operation Range BLDC W No.*mm2 (AWG) Drain Hose(O.D / I.D.) Gross Weight 30 Propeller Liquid Side Power and Transmission Cable Net Weight 20 Propeller Motor Type Circuit Breaker Piping Connections 20 Propeller Outdoor kg(lbs) 35.8(78.9) 35.8(78.9) 46(101.4) Cooling(Outdoor) °C(℉)DB -10(-18)*~48 [14.0(0)*~118.4] -10(-18)*~48 [14.0(0)*~118.4] -10(-18)*~48 [14.0(0)*~118.4] Heating(Outdoor) °C(℉)WB -20(-4)~18(65) -20(-4)~18(65) -20(-4)~18(65) Piping Length (Min/Max) m(ft) 2(6.6) / 20(65.6) 2(6.6) / 20(65.6) 3(9.84) / 20(65.6) Chargeless m(ft) 12.5(41.0) 12.5(41.0) 7.5(24.6) Max. Elevation Difference m(ft) 10(32.8) 10(32.8) 10(32.8) SB / UL2 SB / UL2 SC / UE Tool Code(Chassis) Indoor / Outdoor Note O : Applied, X : Not applied, – : No relation • Filters are optional in some specific areas. • For Circuit Breaker Rating, please conform to local standards whenever necessary. • * : With wind baffle installed, the minimum temperature will be 0℉ D.B. in cooling. 5 _ Wall Mounted-60Hz(R410A) Inverter Single 3. Specifications System FAC Model Name Outdoor Unit Indoor Unit Heating Capacity M30YJ M36YJ MR30Y3J MR36Y3J MW36Y3J MW24Y3J MW30Y3J kW 6.447 8.792 9.671 Btu/h. 22,000 30,000 33,000 10.316 kW 8.088 9.378 Btu/h. 27,000 32,000 35,200 Power Input Cooling/Heating W 1760/2,380 3,000/3,100 4,035/3,840 Running Current Cooling/Heating A 7.9/10.7 13.4/13.9 17.0/16.2 Starting Current Cooling/Heating A 7.9/10.7 13.4/13.9 17.0/16.2 Cooling COP - 3.66 2.93 2.4 EER - 12.5 10 8.2 SEER - 21.5 19 17.5 HSPF Power Supply Power Factor Air Flow Rate 10 10 1, 208/230, 60 1, 208/230, 60 97 97.5 97.5 % m3/min(CFM) Outdoor,Max m3/min(CFM) 60(2,119) 60(2,119) l/h. 2.6 2.8 3.1 Indoor,H/M/L/Sleep dB(A)+3 49 / 44 / 40 / 37 49 / 44 / 40 / 37 49 / 44 / 40 / 37 Outdoor,Max dB(A)+3 55 55 55 g(oz) R410A, 2,200(77.6) R410A, 2,200(77.6) R410A, 2,200(77.6) Refrigerant & Charge (at 7.5 m/24.6ft) Additional Refrigerant charge Compressor 11 1, 208/230, 60 Indoor (QUIET, LOW, MED, HIGH) Moisture Removal Sound Level Ø, V, Hz 13(459)/15(530)/20(706)/24(848) 13(459)/15(530)/20(706)/24(848) 13(459)/15(530)/20(706)/24(848) g/m(oz/ft) 35(0.38) 35(0.38) 35(0.38) Type Twin Rotary Twin Rotary Twin Rotary Model GJT240MAB GJT240MAB GJT240MAB BLDC BLDC BLDC PVE(FVC68D) PVE(FVC68D) PVE(FVC68D) 900 900 900 - - - Cross Flow Fan Cross Flow Fan Cross Flow Fan Motor Type Oil Type Oil Charge cc O.L.P. name Type Fan(Indoor) Motor Output W Type Fan(Outdoor) 113.1 113.1 113.1 Propeller, Fan Propeller, Fan Propeller, Fan Motor Type Motor Output Circuit Breaker Power Supply Cable BLDC BLDC BLDC W 124 124 124 A 35 35 35 No.*mm2 (AWG) 3*2.5(12) 3*2.5(12) 3*2.5(12) 4*1.0(18) No.*mm2 (AWG) 4*1.0(18) 4*1.0(18) Liquid Side mm(in) 9.52(3/8) 9.52(3/8) 9.52(3/8) Gas Side mm(in) 15.88(5/8) 15.88(5/8) 15.88(5/8) mm(in) 21.5 / 16.0(0.85 / 0.63) 21.5 / 16.0(0.85 / 0.63) 21.5 / 16.0(0.85 / 0.63) mm 1190*346*265 1190*346*265 1190*346*265 inch 46.9*13.6*10.4 46.9*13.6*10.4 46.9*13.6*10.4 Power and Transmission Cable Piping Connections 60(2,119) Drain Hose(O.D / I.D.) Indoor (W*H*D) Dimensions Outdoor (W*H*D) mm 870*800*320 870*800*320 870*800*320 inch 34.3*31.5*12.6 34.3*31.5*12.6 34.3*31.5*12.6 Indoor kg(lbs) 18(39.7) 18(39.7) 18(39.7) Outdoor kg(lbs) 56.5(124.56) 56.5(124.56) 56.5(124.56) Indoor kg(lbs) 20.5(45.2) 20.5(45.2) 20.5(45.2) Outdoor kg(lbs) 60(132.28) 60(132.28) 60(132.28) Cooling(Outdoor) °C(℉)DB -10(-18)*~48 [14.0(0)*~118.4] -10(-18)*~48 [14.0(0)*~118.4] -10(-18)*~48 [14.0(0)*~118.4] Heating(Outdoor) °C(℉)WB -20(-4)~18(65) -20(-4)~18(65) -20(-4)~18(65) Piping Length (Min/Max) m(ft) 3(9.84) / 50(164) 3(9.84) / 50(164) 3(9.84) / 50(164) Chargeless m(ft) 7.5(24.6) 7.5(24.6) 7.5(24.6) Max. Elevation Difference m(ft) 30(98.4) 30(98.4) 30(98.4) SV / UE1+ SV / UE1+ SV / UE1+ Net Weight Gross Weight Operation Range Tool Code(Chassis) Indoor / Outdoor Note O : Applied, X : Not applied, – : No relation • Filters are optional in some specific areas. • For Circuit Breaker Rating, please conform to local standards whenever necessary. • * : With wind baffle installed, the minimum temperature will be 0℉ D.B. in cooling. Wall Mounted-60Hz(R410A) _ 6 Inverter Single Cooling Capacity M24YJ MR24Y3J Inverter Single 3. Specifications kW Btu/h. kW Btu/h. W A A Ø, V, Hz % HM12YJ MRH12Y3J MWH12Y3J 3.516 12,000 3.986 13,600 857/960 3.8/4.3 3.8/4.3 4.1 14 25 11 1, 208/230, 60 97.7 Indoor (QUIET, LOW, MED, HIGH) m3/min(CFM) 5.0(177)/8.0(283)/11.8(417)/14(494) Outdoor,Max m3/min(CFM) 50(1,766) l/h. dB(A)+3 dB(A)+3 g(oz) g/m(oz/ft) W A 1.7 42 / 36 / 25 / 17 51 R410A, 1,250(44.1) 20(0.22) Twin Rotary GKT128MAA BLDC FVC68D 450 Cross Flow Fan 20 Propeller, Fan BLDC 85 15 Power Supply Cable No.*mm2 (AWG) 3*1.0(18) Power and Transmission Cable No.*mm2 (AWG) 4*1.0(18) mm(in) mm(in) mm(in) mm inch mm inch kg(lbs) kg(lbs) kg(lbs) kg(lbs) °C(℉)DB °C(℉)WB m(ft) m(ft) m(ft) 6.35(1/4) 9.52(3/8) 21.5 / 16.0(0.85 / 0.63) 875*295*235 34.4*11.6*9.25 870*655*320 34.3*25.8*12.6 11.0(24.25) 43(94.8) 13.0(28.6) 45(99.2) -10~48 [14.0~118.4] -10(14)~18(65) 3(9.84) / 15(49.2) 7.5(24.6) 7(23) SM / UE Inverter Single FAC Model Name System Outdoor Unit Indoor Unit Cooling Capacity Heating Capacity Power Input Running Current Starting Current Cooling COP EER SEER HSPF Power Supply Power Factor Air Flow Rate Cooling/Heating Cooling/Heating Cooling/Heating Moisture Removal Indoor,H/M/L/Sleep Sound Level Outdoor,Max Refrigerant & Charge (at 7.5 m/24.6ft) Additional Refrigerant charge Type Model Motor Type Compressor Oil Type Oil Charge O.L.P. name Type Fan(Indoor) Motor Output Type Motor Type Fan(Outdoor) Motor Output Circuit Breaker Piping Connections Liquid Side Gas Side Drain Hose(O.D / I.D.) Indoor (W*H*D) Dimensions Outdoor (W*H*D) Net Weight Gross Weight Operation Range Indoor Outdoor Indoor Outdoor Cooling(Outdoor) Heating(Outdoor) Piping Length (Min/Max) Chargeless Max. Elevation Difference Tool Code(Chassis) Indoor / Outdoor cc W Note O : Applied, X : Not applied, – : No relation • Filters are optional in some specific areas. • For Circuit Breaker Rating, please conform to local standards whenever necessary. 7 _ Wall Mounted-60Hz(R410A) Inverter Single 4. Function List Category Air Purifying Installation Reliability Air Supply Outlet Airflow Direction Control (Left & Right) Airflow Direction Control (Up & Down) Auto Swing (Left & Right) Auto Swing (Up & Down) Fan Speed Steps (Fan / Cool / Heat) Natural Wind (Auto Wind) Jet Cool / Jet Heat (Power Wind) Comfort Air Prefilter (Washable / Anti-Bacteria) Deodorizing Filter (Triple) 3M Micro Dust Filter 3M Multi Protection Filter Plasma Air Purifier Drain Pump Hot Start Self Diagnosis De-ice Control (Defrost) Dry (Dehumidification) Operation Auto Changeover Auto Operation (Artificial Intelligence) Auto Cleaning (Coil Dry) Auto Restart Operation Child Lock ¹ Forced Operation Group Control ¹ Sleep Mode Timer 24hr (On/Off) Timer (Weekly) ¹ Two Thermistor Control ¹ Convenience Low Ambient Operation Overheating Protection Energy Saving Individual Control CAC Network Function Special Function Kit Others Low Heating Voice Control Smart Scan (PIR) LG AC Tag On (NFC) Outdoor Silent Mode Mosquito Away Smart Diagnosis Indoor Unit Display Type Indoor Unit Display Light Energy Display Energy Saving Active Energy Control (Watt Option) Wired Remote Controller ² Handheld Wireless Controller General Central Controller Network Solution Dry Contact ² PDI (Power Distribution Indicator) ² Outdoor Unit PI 485 ² Wi-Fi ² Water Level Sensor Connection ² Wind Baffle Kit ² Sump Heater Sheath Heater Crank Case Heater Smart Inverter Monitoring System (SIMs) ² Mode Lock Temperature Control DRED (Demand Response Enabling Device) Description The number of air outlet from the indoor unit Controlling a left-right direction of the indoor air flow Controlling a up-down direction of the indoor air flow Auto swing air flow right and left for quick-cooling& Heating Auto swing air flow up and down for quick-cooling& Heating Step adjustable wind strength at each mode Wind strength changes at regular intervals automatically Wind strength is set to the maximum for 30 minutes Set the vane to a preset position in order to make an indirect wind Capture dust particles over 10μm in size and finer bacteria Deodorizing filter of the three techniques Capture dust particles over 0.3μm in size Capture micro-dust, viruses and allergens Reduce harmful microscopic particles and odor Water drain pump for indoor unit In the heating mode, the hot wind from the beginning Self-diagnostic for product protection In the heating mode, de-icing of the outdoor heat exchanger automatically Prevent the growth of mold by removing excess moisture from an area with high humidity Change the operation mode(cooling & heating) automatically to maintain the set temperature The fan and setting temperature adjust automatically, base on room temperature Prevent the formation of bacteria and mold on the heat exchanger If power is resupplied after blackout, product restart automatically Only for wired-remote controller. Lock the buttons to prevent children control Use the forced switch of the indoor unit to operate the air conditioner when the remote control is unavailable Only for wired-remote controller. Control multiple indoor units at the same time Set the off timer and fan speed is decreasing to make quiet environment for comfort sleep Set the on/off timer Only for wired-remote controller. Set the on/off timer If there is a temperature difference between room temperature and desired temperature, you can use this function in other to prevent insufficient cooling and insufficient heating The cooling operation is possible even in conditions of extreme cold If there is a temperature difference between room temperature and desired temperature, you can use this function in other to prevent over-heating Using less energy helps keep the room warm when going out Customer can control the aircon by voice without wireless remote controller Adjust more energy saving and greater comfort air for detecting the human movement by sensor Check the your AC’s operational information for quick-service and self-diagnosis by using NFC The overall sound level of the outdoor unit drops by up to 3dB An ultrasonic sound that mosquitoes detest is emitted to drives away mosquitoes Check the your AC’s operational information for quick-service and self-diagnosis by sound from indoor unit Show the power consumption Control the optimal desired temperature to save energy The customer can control the power consumption directly to save energy Prevent the accumulation of freezing on the outdoor-heat-exchanger during winter (Flexible Type) Prevent the accumulation of freezing on the outdoor-heat-exchanger during winter (Hard Type) Pre-heating the compressor during winter Help you to easily monitor, diagnose the air conditioner and get a quick resolution Set up the unit available to use only cooling or heating mode in the heat pump model Basic cycle control method - Note • These functions must be applied according to the model. Please refer to the following function list for each model. • ¹ : This function can be operated only when the wired remote controller is connected. The applicability of each function depends on the above table. • ² : Optional accessories must be purchased separately. Wall Mounted-60Hz(R410A) _ 8 Inverter Single Air Flow Function Inverter Single 4. Function List Inverter Single Category Function Air Supply Outlet Airflow Direction Control (Left & Right) Airflow Direction Control (Up & Down) Auto Swing (Left & Right) Air Flow Auto Swing (Up & Down) Fan Speed Steps (Fan / Cool / Heat) Natural Wind (Auto Wind) Jet Cool / Jet Heat (Power Wind) Comfort Air Prefilter (Washable / Anti-Bacteria) Deodorizing Filter (Triple) Air 3M Micro Dust Filter Purifying 3M Multi Protection Filter Plasma Air Purifier Installation Drain Pump Hot Start Self Diagnosis Reliability De-ice Control (Defrost) Dry (Dehumidification) Operation Auto Changeover Auto Operation (Artificial Intelligence) Auto Cleaning (Coil Dry) Auto Restart Operation Child Lock ¹ Forced Operation Group Control ¹ Sleep Mode Timer 24hr (On/Off) Timer (Weekly) ¹ Two Thermistor Control ¹ ConvenLow Ambient Operation ience Overheating Protection Low Heating Voice Control Smart Scan (PIR) LG AC Tag On (NFC) Outdoor Silent Mode Mosquito Away Smart Diagnosis Indoor Unit Display Type Indoor Unit Display Light Energy Display Energy Energy Saving Saving Active Energy Control (Watt Option) Wired Remote Controller (Premium) ² Wired Remote Controller (Standard) ² Wired Remote Controller (Simple with Mode Selection) ² Individual Wired Remote Controller (Simple without Mode Selection) ² Control (See Remote Controller Section) Handheld Wireless Setting Temperature Range (Cooling) Controller Setting Temperature Range (Heating) General Central Controller Network Solution CAC Network Dry Contact ² Function PDI (Power Distribution Indicator) ² Outdoor Unit PI 485 ² Wi-Fi ² Water Level Sensor Connection ² Special Wind Baffle Kit ² Function Sump Heater Kit Sheath Heater Crank Case Heater Smart Invert Monitoring System (SIMs) ² Mode Lock Others Temperature Control DRED (Demand Response Enabling Device) M09CJ 1 5 Steps 6 Steps O O 6/6/X O O/X X O X X X X X O O X O X O O O O O X 7hr O O O O X X X X X X X X 3 LED On/Off X O X X DWC1 X X AKB73456119 64~86 ℉ (18~30 ℃) X X X M12CJ 1 5 Steps 6 Steps O O 6/6/X O O/X X O X X X X X O O X O X O O O O O X 7hr O O O O X X X X X X X X 3 LED On/Off X O X X DWC1 X X AKB73456119 64~86 ℉ (18~30 ℃) X X X M18CJ 1 5 Steps 6 Steps O O 6/6/X O O/X X O X X X X X O O X O X O O O O O X 7hr O O O O X X X X X X X X 3 LED On/Off X O X X DWC1 X X AKB73975604 64~86 ℉ (18~30 ℃) X X X M24CJ 1 5 Steps 6 Steps O O 6/6/X O O/X X O X X X X X O O X O X O O O O O X 7hr O O O O X X X X X X X X 3 LED On/Off X O X X DWC1 X X AKB73975604 64~86 ℉ (18~30 ℃) X X X X X X X X X X O O X X X DWTST X Thermistor X X X X O O X X X DWTST X Thermistor X X X X O O X X X DWTST X Thermistor X X X X O O X X X DWTST X Thermistor X Note O : Applied, X : Not Applied • Filters are optional in some specific areas. • ¹ : This function can be operated only when the wired remote controller is connected. The applicability of each function depends on the above table. • ² : Optional accessories must be purchased separately. • Due to our policy of innovation some specifications may be changed without notifications. 9 _ Wall Mounted-60Hz(R410A) Inverter Single 4. Function List Category M09YJ 1 5 Steps 6 Steps O O 6/6/6 O O/O X O X X X X X O O O O O X O O O O X 7hr O O O O O X X X X X X X 3 LED On/Off X O X X DWC1 X X AKB73456118 64~86 ℉ (18~30 ℃) 60~86 ℉ (16~30 ℃) X X M12YJ 1 5 Steps 6 Steps O O 6/6/6 O O/O X O X X X X X O O O O O X O O O O X 7hr O O O O O X X X X X X X 3 LED On/Off X O X X DWC1 X X AKB73456118 64~86 ℉ (18~30 ℃) 60~86 ℉ (16~30 ℃) X X M18YJ 1 5 Steps 6 Steps O O 6/6/6 O O/O X O X X X X X O O O O O X O O O O X 7hr O O O O O X X X X X X X 3 LED On/Off X O X X DWC1 X X AKB73975603 64~86 ℉ (18~30 ℃) 60~86 ℉ (16~30 ℃) X X X X X X X X O O O X X DWTST X Thermistor X X X X O O O X X DWTST X Thermistor X X X X O O X X X DWTST X Thermistor X Note O : Applied, X : Not Applied • Filters are optional in some specific areas. • ¹ : This function can be operated only when the wired remote controller is connected. The applicability of each function depends on the above table. • ² : Optional accessories must be purchased separately. • Due to our policy of innovation some specifications may be changed without notifications. Wall Mounted-60Hz(R410A) _ 10 Inverter Single Function Air Supply Outlet Airflow Direction Control (Left & Right) Airflow Direction Control (Up & Down) Auto Swing (Left & Right) Air Flow Auto Swing (Up & Down) Fan Speed Steps (Fan / Cool / Heat) Natural Wind (Auto Wind) Jet Cool / Jet Heat (Power Wind) Comfort Air Prefilter (Washable / Anti-Bacteria) Deodorizing Filter (Triple) Air 3M Micro Dust Filter Purifying 3M Multi Protection Filter Plasma Air Purifier Installation Drain Pump Hot Start Self Diagnosis Reliability De-ice Control (Defrost) Dry (Dehumidification) Operation Auto Changeover Auto Operation (Artificial Intelligence) Auto Cleaning (Coil Dry) Auto Restart Operation Child Lock ¹ Forced Operation Group Control ¹ Sleep Mode Timer 24hr (On/Off) Timer (Weekly) ¹ Two Thermistor Control ¹ Convenience Low Ambient Operation Overheating Protection Low Heating Voice Control Smart Scan (PIR) LG AC Tag On (NFC) Outdoor Silent Mode Mosquito Away Smart Diagnosis Indoor Unit Display Type Indoor Unit Display Light Energy Display Energy Sav- Energy Saving ing Active Energy Control (Watt Option) Wired Remote Controller (Premium) ² Wired Remote Controller (Standard) ² Wired Remote Controller (Simple with Mode Selection) ² Individual Wired Remote Controller (Simple without Mode Selection) ² Control (See Remote Controller Section) Handheld Wireless Setting Temperature Range (Cooling) Controller Setting Temperature Range (Heating) General Central Controller Network Solution CAC Dry Contact ² Network Function PDI (Power Distribution Indicator) ² Outdoor Unit PI 485 ² Wi-Fi ² Water Level Sensor Connection ² Wind Baffle Kit ² Special Sump Heater Function Kit Sheath Heater Crank Case Heater Smart Invert Monitoring System (SIMs) ² Mode Lock Others Temperature Control DRED (Demand Response Enabling Device) Inverter Single 4. Function List Inverter Single Category Function Air Supply Outlet Airflow Direction Control (Left & Right) Airflow Direction Control (Up & Down) Auto Swing (Left & Right) Air Flow Auto Swing (Up & Down) Fan Speed Steps (Fan / Cool / Heat) Natural Wind (Auto Wind) Jet Cool / Jet Heat (Power Wind) Comfort Air Prefilter (Washable / Anti-Bacteria) Deodorizing Filter (Triple) Air 3M Micro Dust Filter Purifying 3M Multi Protection Filter Plasma Air Purifier Installation Drain Pump Hot Start Self Diagnosis Reliability De-ice Control (Defrost) Dry (Dehumidification) Operation Auto Changeover Auto Operation (Artificial Intelligence) Auto Cleaning (Coil Dry) Auto Restart Operation Child Lock ¹ Forced Operation Group Control ¹ Sleep Mode Timer 24hr (On/Off) Timer (Weekly) ¹ Two Thermistor Control ¹ ConvenLow Ambient Operation ience Overheating Protection Low Heating Voice Control Smart Scan (PIR) LG AC Tag On (NFC) Outdoor Silent Mode Mosquito Away Smart Diagnosis Indoor Unit Display Type Indoor Unit Display Light Energy Display Energy Energy Saving Saving Active Energy Control (Watt Option) Wired Remote Controller (Premium) ² Wired Remote Controller (Standard) ² Wired Remote Controller (Simple with Mode Selection) ² Individual Wired Remote Controller (Simple without Mode Selection) ² Control (See Remote Controller Section) Handheld Wireless Setting Temperature Range (Cooling) Controller Setting Temperature Range (Heating) General Central Controller Network Solution CAC Network Dry Contact ² Function PDI (Power Distribution Indicator) ² Outdoor Unit PI 485 ² Wi-Fi ² Water Level Sensor Connection ² Special Wind Baffle Kit ² Function Sump Heater Kit Sheath Heater Crank Case Heater Smart Invert Monitoring System (SIMs) ² Mode Lock Others Temperature Control DRED (Demand Response Enabling Device) M24YJ 1 5 Steps 6 Steps O O 6/6/6 O O/O X O X X O X X O O O O O X O O O O X 7hr O O O O O X X X X X X X Number Display On/Off X O X X DWC1 X X AKB73975603 64~86 ℉ (18~30 ℃) 60~86 ℉ (16~30 ℃) X X M30YJ 1 5 Steps 6 Steps O O 6/6/6 O O/O X O X X O X X O O O O O X O O O O X 7hr O O O O O X X X X X X X Number Display On/Off X O X X DWC1 X X AKB73975603 64~86 ℉ (18~30 ℃) 60~86 ℉ (16~30 ℃) X X M36YJ 1 5 Steps 6 Steps O O 6/6/6 O O/O X O X X O X X O O O O O X O O O O X 7hr O O O O O X X X X X X X Number Display On/Off X O X X DWC1 X X AKB73975603 64~86 ℉ (18~30 ℃) 60~86 ℉ (16~30 ℃) X X HM12YJ 1 5 Steps 6 Steps O O 6/6/6 O O/O X O X X X X X O O O O O X O O O O X 7hr O O O O O X X X X X X X Number Display On/Off X O X X DWC1 X X AKB73975603 64~86 ℉ (18~30 ℃) 60~86 ℉ (16~30 ℃) X X X X X X X X X O O X X X DWTST X Thermistor X X X X O O X X X DWTST X Thermistor X X X X O O X X X DWTST X Thermistor X X X X O X X X X DWTST X Thermistor X Note O : Applied, X : Not Applied • Filters are optional in some specific areas. • ¹ : This function can be operated only when the wired remote controller is connected. The applicability of each function depends on the above table. • ² : Optional accessories must be purchased separately. • Due to our policy of innovation some specifications may be changed without notifications. 11 _ Wall Mounted-60Hz(R410A) Wall Mounted-60Hz(R410A) _ 12 1-31/32(50) 2-3/8(60) 1-3/32 (50.2) 5-31/32 (152) 1/8(3) x 1/4(6) 1/4(6) x 1/8(3) 2-7/16 (61.5) 1-1/4 (31) 1-1/16 (26.2) 2-3/16 (55) 1-3/4(45) 1-9/32(32.7) 5/8(15.3) 1-7/16(33.5) 1 9-5/8 (245) Ø2-9/16 (65) 2-5/16(59.5) 7 (178) 5 18-7/8 (480) 6-5/16(159.5) Right Rear 4-13/16 (123) Piping Installation Plate Place a level on raised tab 4 2 1-31/32 (53) 11-1/4(285) Left Rear 5-1/4 (136) Piping Ø2-9/16 (65) Unit Outline 16-1/4 (412) 34-13/16(885) 3 No 1 2 3 4 5 1-3/4(45) 1-31/32(50) Part Name Front Panel Display & Signal Receiver Air Suction Grille Knockout Hole Installation Plate 8-1/4(210) MW09C1J MW09Y3J For pipe and cable Remark MW12C1J MW12Y3J SB Chassis Inverter Single Unit : inch (mm) Inverter Single 5. Dimensional Drawings 5.1 Indoor Unit 2-13/32(61) 2-1/32(52) 1-3/32 (50.2) 5-31/32 (152) 13 _ Wall Mounted-60Hz(R410A) 1/8(3) x 1/4(6) 1/4(6) x 1/8(3) 2-7/16 (61.5) 1-1/4 (31) 1-1/16 (26.2) 2-17/32(64) 1-13/16(46) 1-9/32(32.7) 5/8(15.3) Unit : inch (mm) 1-7/16(33.5) 7.24in(184mm) 7-1/4(184) 8-11/16(220) Left Rear Piping Ø2-9/16(65) Unit Outline 18-1/8(460) Place a level on raised tab 40-9/16 (1030) 12-13/16 (325) 5 12-3/32(307) 6-5/32(156) 6.14in(156mm) Right Rear Piping Ø2-9/16(65) 22-11/32(567) No 1 2 3 4 5 4 For pipe and cable Remark MW24C3J SC Chassis MW18C3J MW18Y3J Part Name Front Panel Display & Signal Receiver Air Suction Grille Knockout Hole Installation Plate 1-13/16(46) 9-11/16(245) 2-1/32(52) 2-13/32(61) Inverter Single Inverter Single 5. Dimensional Drawings Wall Mounted-60Hz(R410A) _ 14 1/8(3) x 1/4(6) 1/4(6) x 1/8(3) 2-13/32(61) 1-7/16(33.5) 6-9/16 (167) 2-7/16 (61.5) 1-1/4 (31) 2-17/32 (Ø65) 5-31/32 (152) 1-1/16 (26.2) 1-11/16 (43) 1-3/32 (50.2) 1-9/32(32.7) 5/8(15.3) 1 4-23/32 (120) 33-25/32 (858) 5 6-9/16 (167) 4-23/32 (120) 17-7/32 (335) 1-11/16 (43) 46-7/8 (1190) 2-17/32 (Ø65) 2 10-7/16 (265) 3 2-17/32 (65) 13-5/8 (346) 2-11/32 (60) No 1 2 3 4 5 4 Part Name Front Panel Display & Signal Receiver Air Suction Grille Knockout Hole Installation Plate MW24Y3J MW36Y3J For pipe and cable Remark MW30Y3J SV Chassis Inverter Single Unit : inch (mm) Inverter Single 5. Dimensional Drawings 5-31/32 (152) 2-5/32 (55) 1-3/32 (50.2) 1-7/16(33.5) 11-5/8 (295) 2-13/32(61) Left rear piping 1/8(3) x 1/4(6) 1/4(6) x 1/8(3) 2-7/16 (61.5) 1-1/4 (31) 1-1/16 (26.2) 1-31/32 (50) 1-9/32(32.7) 5/8(15.3) 4-13/16 (123) 6-29/32 (175) Ø2-9/16 (65) 34-7/16 (875) 5 1 Ø2-9/16 (65) 6-11/16 (170) 8-17/32 (217) 17-5/16 (439) Place a level on raised tab Unit Outline 17 (434) 3 2 11-5/8 (295) Right rear piping 31/32 (24.6) 1-7/8 (47.5) 15 _ Wall Mounted-60Hz(R410A) 1-31/32 (50) Unit : inch (mm) 4 1-31/32 (50) 9-1/4 (235) 2-5/32 (55) No 1 2 3 4 5 Part Name Front Panel Display & Signal Receiver Air Suction Grille Knockout Hole Installation Plate For pipe and cable Remark MWH12Y3J SM Chassis Inverter Single Inverter Single 5. Dimensional Drawings 1 10-29/32 (277) 30-5/16 (770) Ø17-11/32 (440) 4 2-23/32 (69) 13-29/32 (353) 21-1/2 (545) 31/32 (24) 12-31/32 (330) 19/32 (15) 22 (558) No 1 2 3 4 2 3 15/32 (11.5) 25° 13/16 (20) Remark MR12C1J UL2 Chassis MR09C1J 1-7/32 (30.5) 2-3/32 (54) Part Name Air Discharge Grille Gas Pipe Connection Port Liquid Pipe Connection Port Control Box 4-15/16 (125) 11-5/16 (288) 9-5/16 (236) 12-1/16 (306) Drain Hole 8-Ø13/16 (20) 6-7/16 (163) 5-3/32 (129) 4-3/16 (106) 10-1/2(267) 25° Wall Mounted-60Hz(R410A) _ 16 Inverter Single Unit : inch (mm) Inverter Single 5. Dimensional Drawings 5.2 Outdoor Unit 31/32 (24) 4-3/16 (106) 1 10-29/32 (277) 30-5/16 (770) 22 (558) Drain Hole 8-Ø13/16 (20) Ø17-11/32 (440) 4 2-23/32 (69) 13-29/32 (353) 21-1/2 (545) 5 No 1 2 3 4 5 2 3 15/32 (11.5) 25° 13/16 (20) Remark MR12Y3J UL2 Chassis MR09Y3J 1-7/32 (30.5) 2-3/32 (54) Part Name Air Discharge Grille Gas Pipe Connection Port Liquid Pipe Connection Port Control Box Sump Heater 4-15/16 (125) 11-5/16 (288) 25° 10-1/2(267) 12-31/32 (330) 19/32 (15) Unit : inch (mm) 9-5/16 (236) 12-1/16 (306) 17 _ Wall Mounted-60Hz(R410A) 6-7/16 (163) 5-3/32 (129) Inverter Single Inverter Single 5. Dimensional Drawings 11-29/32 (301) 1 34-1/4 (870) Ø9-9/32 (470) 4 3-5/32 (80) 14-3/16 (360) 25-13/16 (655) 31/32 (24.5) 12-19/32 (319) 13-13/32 (340) 7/8 (21.5) 21-1/2 (546) No 1 2 3 4 3 2 7/16 (10.5) 12-19/32 (320) 16-31/32 (431) Part Name Air Discharge Grille Gas Pipe Connection Port Liquid Pipe Connection Port Control Box 9-1/16 (230) 9-7/32 (234) 1-25/32 (45) 5-13/16 (147.5) 4-7/32 (107) 6-15/32 (164) 21° 7-11/16 (195) Drain Hole 2-Ø13/16 (20) 25° Wall Mounted-60Hz(R410A) _ 18 2-23/32 (69) MR18Y3J MRH12Y3J Remark MR18C3J UE Chassis Inverter Single Unit : inch (mm) Inverter Single 5. Dimensional Drawings 29/32 (22.5) 6-15/32 (164) 15-3/32 (383) 1 13-3/32 (333) 34-1/4 (870) 21-1/2 (546) 21-1/2 (571) Drain Hole 2-Ø13/16 (20) 4 3-5/32 (79.5) 13-13/32 (340) 14-3/16 (360) 31-1/2 (800) 19 _ Wall Mounted-60Hz(R410A) 7/8 (22) Unit : inch (mm) 2 No 1 2 3 4 14° 4-7/32 (107) 2-3/4 (69.5) Part Name Air Discharge Grille Gas Pipe Connection Port Liquid Pipe Connection Port Control Box 6-25/32 (172) 6-29/32 (175) 25° 3 1-25/32 (45) 12-19/32 (320) 17/32 (13) 5-7/8 (149) 7-11/16 (195) 20-27/32 (529) MR24C3J MR30Y3J Remark MR24Y3J MR36Y3J UE1+ Chassis Inverter Single Inverter Single 5. Dimensional Drawings Inverter Single 5. Dimensional Drawings 5.3 Corner Weight and Center of Gravity Dimension for Outdoor Unit Inverter Single d A D e c C B b a Weight (kg) Shipping Net Center of Gravity (mm) a b c Leg (mm) d e Corner Weight (kg) B C D Model Tool MR09C1J, MR12C1J, MR09Y3J, MR12Y3J UL2 35.8 34.0 507 237 143 558 330 4.4 5.2 12.3 12.1 MRH12Y3J MR18C3J, MR18Y3J MR24C3J UE UE UE1+ 45.0 46.0 58.5 43.0 44.0 55.0 535 535 535 265 265 350 175 175 170 546 546 546 340 340 340 7.8 8.0 9.3 6.0 6.1 8.3 13.5 14.0 17.6 15.7 15.9 19.8 MR24Y3J, MR30Y3J, UE1+ MR36Y3J 60.0 56.5 535 350 170 546 340 9.6 8.5 18.1 20.3 Model MR09C1J, MR12C1J, MR09Y3J, MR12Y3J MRH12Y3J MR18C3J, MR18Y3J MR24C3J MR24Y3J, MR30Y3J, MR36Y3J Tool Weight (lb.) Shipping Net A Center of Gravity (inch) Leg (inch) Corner Weight (lb.) a b c d e A B C D 19129-11/32 5-21/32 22 9.7 11.4 27.0 26.8 31/32 31/32 21-3/32 10-7/16 6-29/32 21-1/2 13-13/32 17.2 13.2 29.7 34.6 21-3/32 10-7/16 6-29/32 21-1/2 13-13/32 17.7 13.4 30.8 35.1 21-3/32 13-25/32 6-23/32 21-1/2 13-13/32 20.6 18.3 38.8 43.6 UL2 78.9 75.0 UE UE UE1+ 99.2 101.4 129.0 94.8 97.0 121.3 UE1+ 132.3 124.6 21-3/32 13-25/32 6-23/32 21-1/2 13-13/32 21.2 18.7 39.9 44.8 Wall Mounted-60Hz(R410A) _ 20 Inverter Single 6. Wiring Diagrams Inverter Single 6.1 Indoor Unit Model : MW09C1J, MW12C1J MEZ65064707 Model : MW09Y3J, MW12Y3J MEZ61860015 21 _ Wall Mounted-60Hz(R410A) Inverter Single 6. Wiring Diagrams Inverter Single Model : MW18C3J, MW24C3J Model : MW18Y3J Wall Mounted-60Hz(R410A) _ 22 Inverter Single Inverter Single 6. Wiring Diagrams Model : MW24Y3J, MW30Y3J, MW36Y3J Model : MWH12Y3J 23 _ Wall Mounted-60Hz(R410A) Inverter Single 6. Wiring Diagrams 6.2 Outdoor Unit Inverter Single Model : MR09C1J, MR12C1J MEZ65064709 Model : MR09Y3J, MR12Y3J MEZ65064708 Wall Mounted-60Hz(R410A) _ 24 Inverter Single Inverter Single 6. Wiring Diagrams Model : MR18C3J Model : MR18Y3J 25 _ Wall Mounted-60Hz(R410A) Inverter Single 6. Wiring Diagrams Inverter Single Model : MR24C3J Model : MR24Y3J, MR30Y3J, MR36Y3J Wall Mounted-60Hz(R410A) _ 26 Inverter Single Inverter Single 6. Wiring Diagrams Model : MRH12Y3J 27 _ Wall Mounted-60Hz(R410A) Inverter Single 7. Refrigerant Cycle Diagrams Model : M09CJ, M12CJ, M18CJ Outdoor Unit FIELD PIPIN G (Copper Tubing) Inverter Single Indoor Unit 2-Way Valve Liquid Side EEV M Th1 Th4 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) M Th3 Th2 3-Way Valve FIELD PIPIN G (Copper Tubing) Th5 Gas Side Th6 Accumulator : Cooling Compressor Loc. Description PCB Connector Th1 Thermistor for indoor air temperature CN-TH1 (Indoor) Th2 Water level sensor (Option) CN-TH2 (Indoor) Th3 Thermistor for evaporator temperature CN-TH3 (Indoor) Th4 Thermistor for outdoor air temperature Th5 Thermistor for condensing temperature Th6 Thermistor for discharge pipe temperature CN-TH1 (Outdoor) CN-TH2 (Outdoor) n Refrigerant Pipe Connection Port Diameters Gas Model Liquid inch mm inch mm M09CJ, M12CJ Ø 3/8 Ø 9.52 Ø 1/4 Ø 6.35 M18CJ Ø 1/2 Ø 12.7 Ø 1/4 Ø 6.35 M Heat Exchanger Appendix 4 Way Valve Pressure Sensor M Propeller Fan EEV (Electronic Expansion Valve) Pressure Switch Cross Flow Fan Capillary Tube Check Valve Compressor 2-Way Valve 3-Way Valve Accumulator Temperature Sensor Flare Joint Wall Mounted-60Hz(R410A) _ 28 Inverter Single 7. Refrigerant Cycle Diagrams Model : M24CJ Inverter Single Indoor Unit Outdoor Unit FIELD PIPIN G (Copper Tubing) 2-Way Valve Liquid Side EEV M Th1 Th4 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) M Th3 Th2 3-Way Valve FIELD PIPIN G (Copper Tubing) Th5 Gas Side Th6 Accumulator : Cooling Compressor Loc. Description PCB Connector Th1 Thermistor for indoor air temperature CN-TH1 (Indoor) Th2 Water level sensor (Option) CN-TH2 (Indoor) Th3 Thermistor for evaporator temperature CN-TH3 (Indoor) Th4 Thermistor for outdoor air temperature Th5 Thermistor for condensing temperature Th6 Thermistor for discharge pipe temperature CN-TH2 (Outdoor) CN-TH3 (Outdoor) n Refrigerant Pipe Connection Port Diameters Gas Model M24CJ Liquid inch mm inch mm Ø 5/8 Ø 15.88 Ø 3/8 Ø 9.52 M Heat Exchanger Appendix M 4 Way Valve Pressure Sensor 29 _ Wall Mounted-60Hz(R410A) Propeller Fan EEV (Electronic Expansion Valve) Pressure Switch Cross Flow Fan Capillary Tube Check Valve Compressor 2-Way Valve 3-Way Valve Flare Joint Accumulator Temperature Sensor Inverter Single 7. Refrigerant Cycle Diagrams Model : M09YJ, M12YJ, M18YJ Outdoor Unit FIELD PIPIN G (Copper Tubing) Inverter Single Indoor Unit 2-Way Valve Liquid Side EEV Th2 M Th1 Th6 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) M Th3 Th4 3-Way Valve Th5 FIELD PIPIN G (Copper Tubing) Reversing Valve Th7 Gas Side Accumulator Th8 : Cooling : Heating Compressor Loc. Description PCB Connector Th1 Thermistor for indoor air temperature Th2 Thermistor for evaporator inlet temperature Th3 Thermistor for evaporator middle temperature CN-TH3 (Indoor) Th4 Thermistor for evaporator outlet temperature CN-TH2 (Indoor) Th5 Water level sensor (Option) CN-LINK (Indoor) Th6 Thermistor for outdoor air temperature Th7 Thermistor for condensing temperature Th8 Thermistor for discharge pipe temperature CN-TH1 (Indoor) CN-TH1 (Outdoor) CN-TH2 (Outdoor) n Refrigerant Pipe Connection Port Diameters Gas Model Liquid inch mm inch mm M09YJ, M12YJ Ø 3/8 Ø 9.52 Ø 1/4 Ø 6.35 M18YJ Ø 1/2 Ø 12.7 Ø 1/4 Ø 6.35 M Heat Exchanger Appendix 4 Way Valve Pressure Sensor M Propeller Fan EEV (Electronic Expansion Valve) Pressure Switch Cross Flow Fan Capillary Tube Check Valve Compressor 2-Way Valve 3-Way Valve Accumulator Temperature Sensor Flare Joint Wall Mounted-60Hz(R410A) _ 30 Inverter Single 7. Refrigerant Cycle Diagrams Model : M24YJ, M30YJ, M36YJ, HM12YJ Inverter Single Indoor Unit Outdoor Unit FIELD PIPIN G (Copper Tubing) 2-Way Valve Liquid Side EEV M Th1 Th4 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) M Th3 Th2 3-Way Valve FIELD PIPIN G (Copper Tubing) Reversing Valve Th5 Gas Side Accumulator Th6 : Cooling : Heating Compressor Loc. Description PCB Connector Th1 Thermistor for indoor air temperature CN-TH1 (Indoor) Th2 Water level sensor (Option) CN-TH2 (Indoor) Th3 Thermistor for evaporator temperature CN-TH3 (Indoor) Th4 Thermistor for outdoor air temperature Th5 Thermistor for condensing temperature Th6 Thermistor for discharge pipe temperature CN-TH2 (Outdoor) CN-TH3 (Outdoor) n Refrigerant Pipe Connection Port Diameters Gas Model Liquid inch mm inch mm HM12YJ Ø 3/8 Ø 9.52 Ø 1/4 Ø 6.35 M24YJ, M30YJ, M36YJ Ø 5/8 Ø 15.88 Ø 3/8 Ø 9.52 M Heat Exchanger Appendix M 4 Way Valve Pressure Sensor 31 _ Wall Mounted-60Hz(R410A) Propeller Fan EEV (Electronic Expansion Valve) Pressure Switch Cross Flow Fan Capillary Tube Check Valve Compressor 2-Way Valve 3-Way Valve Flare Joint Accumulator Temperature Sensor Inverter Single 8. Capacity Tables 8.1 Rated Cooling Capacity Indoor Air Temperature : ℉DB / ℉WB Outdoor Air Temp. ℉DB 64 / 53 TC SHC 68 / 57 PI TC SHC 72 / 61 PI TC SHC 77 / 64 PI TC SHC 80 / 67 PI TC SHC 86 / 72 PI TC SHC 90 / 75 PI TC SHC PI 0 5.45 4.48 0.26 6.81 4.77 0.31 8.18 5.06 0.36 9.88 5.43 0.42 10.91 5.64 0.46 9.10 6.16 0.37 7.90 6.50 0.32 5 5.34 4.42 0.28 6.68 4.71 0.33 8.02 4.99 0.38 9.69 5.35 0.44 10.70 5.56 0.48 8.93 6.07 0.39 7.75 6.40 0.33 7 5.38 4.46 0.28 6.73 4.75 0.33 8.08 5.04 0.38 9.76 5.40 0.44 10.77 5.62 0.48 8.99 6.12 0.39 7.80 6.46 0.33 10 5.44 4.52 0.28 6.80 4.81 0.33 8.16 5.11 0.39 9.86 5.47 0.45 10.88 5.69 0.49 9.08 6.21 0.40 7.88 6.55 0.34 14 5.51 4.60 0.29 6.89 4.90 0.34 8.27 5.20 0.39 9.99 5.57 0.46 11.03 5.80 0.50 9.20 6.32 0.41 7.99 6.67 0.35 23 5.92 4.94 0.28 7.12 5.26 0.34 8.32 5.58 0.40 9.82 5.98 0.48 10.72 6.22 0.52 9.43 6.79 0.42 8.57 7.16 0.35 25 6.01 5.02 0.29 7.18 5.33 0.35 8.36 5.64 0.41 9.83 6.03 0.48 10.71 6.26 0.52 9.54 6.86 0.42 8.75 7.26 0.36 30 6.24 5.21 0.31 7.35 5.50 0.37 8.46 5.79 0.42 9.85 6.15 0.49 10.68 6.36 0.53 9.80 7.04 0.44 9.20 7.49 0.38 35 6.47 5.41 0.34 7.52 5.67 0.39 8.56 5.93 0.43 9.87 6.26 0.50 10.66 6.46 0.53 10.05 7.22 0.46 9.65 7.73 0.41 40 6.70 5.60 0.36 7.69 5.84 0.40 8.67 6.08 0.45 9.90 6.38 0.50 10.63 6.56 0.54 10.31 7.41 0.47 10.10 7.97 0.43 45 6.94 5.80 0.38 7.85 6.01 0.42 8.77 6.23 0.46 9.92 6.50 0.51 10.61 6.66 0.54 10.57 7.59 0.49 10.55 8.20 0.46 50 7.17 5.99 0.40 8.02 6.18 0.44 8.88 6.38 0.47 9.94 6.62 0.52 10.58 6.76 0.55 10.83 7.77 0.51 11.00 8.44 0.48 55 7.40 6.18 0.42 8.19 6.35 0.45 8.98 6.52 0.49 9.96 6.73 0.53 10.56 6.86 0.55 11.09 7.95 0.53 11.45 8.68 0.51 60 7.63 6.38 0.44 8.36 6.52 0.47 9.08 6.67 0.50 9.99 6.85 0.53 10.53 6.96 0.55 11.35 8.13 0.54 11.90 8.92 0.53 65 7.56 6.32 0.46 8.25 6.50 0.49 8.94 6.67 0.52 9.80 6.90 0.55 10.31 7.03 0.57 11.13 8.14 0.57 11.68 8.88 0.56 70 7.49 6.26 0.49 8.14 6.47 0.51 8.79 6.68 0.54 9.61 6.94 0.57 10.09 7.10 0.59 10.91 8.14 0.59 11.46 8.84 0.59 75 7.43 6.20 0.51 8.04 6.44 0.53 8.65 6.68 0.56 9.42 6.98 0.59 9.87 7.16 0.61 10.69 8.15 0.61 11.24 8.80 0.62 80 7.36 6.15 0.53 7.93 6.42 0.56 8.51 6.69 0.58 9.22 7.03 0.61 9.66 7.23 0.62 10.48 8.15 0.64 11.02 8.77 0.64 85 7.29 6.09 0.56 7.82 6.39 0.58 8.36 6.69 0.60 9.03 7.07 0.63 9.44 7.30 0.64 10.26 8.16 0.66 10.80 8.73 0.67 90 7.22 6.03 0.58 7.72 6.37 0.60 8.22 6.70 0.62 8.84 7.12 0.64 9.22 7.37 0.66 10.04 8.16 0.68 10.58 8.69 0.70 95 7.15 5.97 0.60 7.61 6.34 0.62 8.07 6.70 0.64 8.65 7.16 0.66 9.00 7.43 0.68 9.82 8.17 0.71 10.36 8.66 0.73 100 6.96 5.82 0.61 7.43 6.20 0.63 7.91 6.58 0.65 8.50 7.06 0.67 8.86 7.34 0.69 9.65 8.04 0.72 10.17 8.50 0.74 105 6.77 5.66 0.62 7.26 6.06 0.64 7.75 6.46 0.66 8.35 6.96 0.68 8.72 7.26 0.70 9.48 7.91 0.73 9.99 8.34 0.75 110 6.59 5.50 0.63 7.08 5.92 0.65 7.58 6.33 0.67 8.21 6.85 0.69 8.58 7.17 0.71 9.31 7.78 0.74 9.80 8.19 0.76 115 6.35 5.31 0.63 6.83 5.71 0.65 7.32 6.12 0.67 7.92 6.62 0.70 8.28 6.93 0.71 8.99 7.52 0.75 9.47 7.91 0.77 118 6.21 5.19 0.64 6.68 5.59 0.66 7.16 5.98 0.68 7.75 6.48 0.70 8.10 6.78 0.72 8.80 7.36 0.75 9.27 7.74 0.77 122 6.02 5.29 0.64 6.48 5.70 0.67 6.94 6.10 0.69 7.51 6.61 0.71 7.86 6.92 0.73 8.54 7.51 0.76 8.99 7.90 0.78 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] SHC : Sensible Heating Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. : Cooling range can be extended from 14 ℉ down to 0 ℉ using the Low Ambient Wind Baffle Kit (sold separately). 3. : Indicates reference data. When operating at this temperature, these values can be different by discontinuous operation. 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on the following conditions : - Interconnecting Piping Length 24.6 ft (7.5 m) - Level Difference of Zero. - Indoor Air Temperature : 80 ℉ (26.7 ℃) DB / 67 ℉ (19.4 ℃) WB - Outdoor Air Temperature : 95 ℉ (35.0 ℃) DB / 75 ℉ (23.9 ℃) WB Wall Mounted-60Hz(R410A) _ 32 Inverter Single Model : M09CJ Inverter Single 8. Capacity Tables Inverter Single Model : M12CJ Indoor Air Temperature : ℉DB / ℉WB Outdoor Air Temp. ℉DB 64 / 53 TC SHC 68 / 57 PI TC SHC 72 / 61 PI TC SHC 77 / 64 PI TC SHC 80 / 67 PI TC SHC 86 / 72 PI TC SHC 90 / 75 PI TC SHC PI 0 6.42 5.27 0.32 8.02 5.61 0.37 9.63 5.96 0.43 11.64 6.38 0.51 12.85 6.64 0.55 10.72 7.24 0.45 9.30 7.64 0.38 5 6.30 5.20 0.33 7.87 5.54 0.39 9.45 5.87 0.45 11.42 6.29 0.53 12.60 6.55 0.57 10.51 7.14 0.47 9.12 7.53 0.40 7 6.34 5.25 0.33 7.93 5.59 0.40 9.51 5.93 0.46 11.50 6.35 0.53 12.69 6.61 0.58 10.59 7.20 0.47 9.19 7.60 0.40 10 6.40 5.32 0.34 8.01 5.66 0.40 9.61 6.01 0.46 11.61 6.44 0.54 12.82 6.70 0.59 10.69 7.30 0.48 9.28 7.71 0.41 14 6.49 5.41 0.35 8.12 5.76 0.41 9.74 6.12 0.47 11.77 6.55 0.55 12.99 6.82 0.60 10.84 7.43 0.49 9.41 7.85 0.42 23 6.97 5.81 0.34 8.38 6.19 0.41 9.80 6.56 0.49 11.56 7.03 0.58 12.62 7.32 0.63 11.11 7.98 0.50 10.10 8.43 0.42 25 7.08 5.90 0.35 8.46 6.27 0.42 9.84 6.63 0.49 11.57 7.09 0.58 12.61 7.36 0.63 11.23 8.07 0.51 10.31 8.54 0.43 30 7.35 6.13 0.38 8.66 6.47 0.44 9.97 6.81 0.51 11.60 7.23 0.59 12.58 7.48 0.64 11.54 8.28 0.53 10.84 8.82 0.46 35 7.62 6.36 0.40 8.86 6.67 0.46 10.09 6.98 0.52 11.63 7.37 0.60 12.55 7.60 0.64 11.84 8.50 0.55 11.37 9.09 0.49 40 7.90 6.59 0.43 9.05 6.87 0.48 10.21 7.15 0.54 11.65 7.51 0.61 12.52 7.72 0.65 12.15 8.71 0.57 11.90 9.37 0.52 45 8.17 6.82 0.46 9.25 7.07 0.50 10.33 7.33 0.55 11.68 7.65 0.62 12.49 7.84 0.65 12.45 8.93 0.59 12.43 9.65 0.55 50 8.44 7.05 0.48 9.45 7.27 0.53 10.45 7.50 0.57 11.71 7.78 0.62 12.46 7.95 0.66 12.76 9.14 0.61 12.96 9.93 0.58 55 8.72 7.27 0.51 9.65 7.47 0.55 10.57 7.67 0.58 11.74 7.92 0.63 12.43 8.07 0.66 13.06 9.35 0.63 13.49 10.21 0.61 60 8.99 7.50 0.53 9.84 7.67 0.57 10.70 7.85 0.60 11.76 8.06 0.64 12.40 8.19 0.67 13.37 9.57 0.65 14.02 10.49 0.64 65 8.91 7.43 0.56 9.72 7.64 0.59 10.53 7.85 0.62 11.54 8.11 0.66 12.14 8.27 0.69 13.11 9.57 0.68 13.76 10.44 0.68 70 8.83 7.37 0.59 9.59 7.61 0.62 10.36 7.86 0.65 11.31 8.16 0.69 11.89 8.35 0.71 12.85 9.58 0.71 13.50 10.40 0.71 75 8.75 7.30 0.61 9.47 7.58 0.64 10.19 7.86 0.67 11.09 8.22 0.71 11.63 8.43 0.73 12.60 9.59 0.74 13.24 10.36 0.74 80 8.66 7.23 0.64 9.34 7.55 0.67 10.02 7.87 0.70 10.86 8.27 0.73 11.37 8.51 0.75 12.34 9.59 0.77 12.98 10.31 0.78 85 8.58 7.16 0.67 9.21 7.52 0.69 9.85 7.87 0.72 10.64 8.32 0.75 11.11 8.59 0.77 12.08 9.60 0.79 12.72 10.27 0.81 90 8.50 7.09 0.70 9.09 7.49 0.72 9.68 7.88 0.74 10.42 8.37 0.78 10.86 8.67 0.79 11.82 9.60 0.82 12.46 10.23 0.84 95 8.42 7.03 0.72 8.96 7.46 0.75 9.51 7.89 0.77 10.19 8.42 0.80 10.60 8.75 0.82 11.56 9.61 0.85 12.20 10.18 0.88 100 8.20 6.84 0.73 8.76 7.29 0.76 9.32 7.74 0.78 10.02 8.30 0.81 10.43 8.64 0.83 11.36 9.46 0.86 11.98 10.00 0.89 105 7.98 6.66 0.74 8.55 7.13 0.77 9.12 7.60 0.79 9.84 8.18 0.82 10.27 8.54 0.84 11.16 9.30 0.88 11.76 9.81 0.90 110 7.76 6.47 0.75 8.34 6.96 0.78 8.93 7.45 0.80 9.66 8.06 0.83 10.10 8.43 0.85 10.97 9.15 0.89 11.54 9.63 0.91 115 7.48 6.24 0.76 8.05 6.72 0.79 8.62 7.19 0.81 9.33 7.79 0.84 9.75 8.15 0.86 10.59 8.84 0.90 11.15 9.30 0.92 118 7.31 6.10 0.77 7.87 6.57 0.79 8.43 7.04 0.82 9.12 7.62 0.85 9.54 7.98 0.87 10.37 8.66 0.90 10.92 9.11 0.93 122 7.09 6.23 0.78 7.63 6.70 0.80 8.17 7.18 0.83 8.85 7.78 0.86 9.25 8.14 0.87 10.06 8.83 0.91 10.59 9.29 0.94 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] SHC : Sensible Heating Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) 33 _ Wall Mounted-60Hz(R410A) Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. : Cooling range can be extended from 14 ℉ down to 0 ℉ using the Low Ambient Wind Baffle Kit (sold separately). 3. : Indicates reference data. When operating at this temperature, these values can be different by discontinuous operation. 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on the following conditions : - Interconnecting Piping Length 24.6 ft (7.5 m) - Level Difference of Zero. - Indoor Air Temperature : 80 ℉ (26.7 ℃) DB / 67 ℉ (19.4 ℃) WB - Outdoor Air Temperature : 95 ℉ (35.0 ℃) DB / 75 ℉ (23.9 ℃) WB Inverter Single 8. Capacity Tables Model : M18CJ ℉DB 64 / 53 TC SHC 68 / 57 PI TC SHC 72 / 61 PI TC SHC 77 / 64 PI TC SHC 80 / 67 PI TC SHC 86 / 72 PI TC SHC 90 / 75 PI TC SHC PI 0 10.29 8.22 0.55 12.87 8.75 0.65 15.45 9.29 0.75 18.67 9.95 0.88 20.60 10.35 0.95 17.19 11.29 0.78 14.92 11.91 0.66 5 10.10 8.10 0.58 12.62 8.63 0.68 15.15 9.15 0.79 18.31 9.81 0.92 20.21 10.21 1.00 16.86 11.13 0.81 14.63 11.75 0.69 7 10.17 8.18 0.58 12.71 8.71 0.69 15.26 9.24 0.80 18.44 9.90 0.93 20.35 10.30 1.01 16.98 11.23 0.82 14.73 11.85 0.70 10 10.27 8.29 0.59 12.84 8.83 0.70 15.41 9.37 0.81 18.63 10.04 0.94 20.55 10.44 1.03 17.15 11.39 0.84 14.88 12.02 0.71 14 10.41 8.44 0.60 13.01 8.99 0.71 15.62 9.53 0.83 18.88 10.22 0.96 20.83 10.63 1.05 17.38 11.59 0.85 15.08 12.23 0.72 23 11.17 9.06 0.60 13.44 9.65 0.72 15.71 10.24 0.85 18.54 10.97 1.00 20.25 11.41 1.09 17.82 12.44 0.87 16.20 13.14 0.72 25 11.35 9.21 0.61 13.57 9.77 0.73 15.79 10.34 0.86 18.56 11.05 1.01 20.23 11.48 1.10 18.01 12.58 0.89 16.54 13.31 0.75 30 11.79 9.56 0.66 13.89 10.09 0.77 15.98 10.61 0.88 18.60 11.27 1.02 20.18 11.66 1.11 18.50 12.91 0.92 17.38 13.74 0.80 35 12.23 9.92 0.70 14.20 10.40 0.81 16.18 10.88 0.91 18.65 11.49 1.04 20.13 11.85 1.12 18.99 13.25 0.96 18.23 14.18 0.85 40 12.66 10.27 0.75 14.52 10.71 0.84 16.37 11.15 0.94 18.69 11.70 1.05 20.08 12.03 1.12 19.48 13.58 0.99 19.08 14.61 0.91 45 13.10 10.63 0.79 14.84 11.03 0.88 16.57 11.42 0.96 18.73 11.92 1.07 20.03 12.22 1.13 19.97 13.92 1.03 19.93 15.05 0.96 50 13.54 10.98 0.84 15.15 11.34 0.91 16.76 11.69 0.99 18.78 12.14 1.08 19.99 12.40 1.14 20.46 14.25 1.06 20.78 15.48 1.01 55 13.98 11.34 0.88 15.47 11.65 0.95 16.96 11.96 1.02 18.82 12.35 1.10 19.94 12.59 1.15 20.95 14.58 1.10 21.63 15.92 1.07 60 14.42 11.70 0.93 15.79 11.96 0.98 17.15 12.23 1.04 18.86 12.57 1.12 19.89 12.77 1.16 21.44 14.92 1.14 22.48 16.35 1.12 65 14.29 11.59 0.97 15.59 11.92 1.03 16.88 12.24 1.08 18.50 12.65 1.15 19.48 12.89 1.20 21.03 14.93 1.18 22.06 16.28 1.18 70 14.16 11.48 1.02 15.38 11.87 1.07 16.61 12.25 1.13 18.14 12.73 1.19 19.06 13.02 1.23 20.61 14.94 1.23 21.65 16.22 1.23 75 14.03 11.38 1.07 15.18 11.82 1.12 16.34 12.26 1.17 17.78 12.81 1.23 18.65 13.14 1.27 20.20 14.94 1.28 21.23 16.15 1.29 80 13.89 11.27 1.11 14.98 11.77 1.16 16.07 12.27 1.21 17.42 12.89 1.27 18.24 13.26 1.31 19.79 14.95 1.33 20.82 16.08 1.35 85 13.76 11.17 1.16 14.78 11.72 1.21 15.79 12.28 1.25 17.06 12.97 1.31 17.83 13.39 1.34 19.37 14.96 1.38 20.40 16.01 1.41 90 13.63 11.06 1.21 14.58 11.67 1.25 15.52 12.29 1.29 16.70 13.05 1.35 17.41 13.51 1.38 18.96 14.97 1.43 19.99 15.94 1.46 95 13.50 10.96 1.26 14.37 11.63 1.30 15.25 12.29 1.34 16.34 13.13 1.39 17.00 13.63 1.42 18.54 14.98 1.48 19.57 15.88 1.52 100 13.15 10.67 1.27 14.04 11.37 1.32 14.94 12.07 1.36 16.06 12.94 1.41 16.73 13.47 1.44 18.22 14.74 1.50 19.22 15.59 1.54 105 12.79 10.38 1.29 13.71 11.11 1.34 14.63 11.84 1.38 15.78 12.76 1.43 16.47 13.31 1.46 17.91 14.50 1.52 18.86 15.30 1.56 110 12.44 10.09 1.31 13.38 10.85 1.35 14.32 11.62 1.40 15.50 12.57 1.45 16.20 13.14 1.48 17.59 14.26 1.54 18.51 15.01 1.59 115 12.00 9.73 1.33 12.91 10.47 1.37 13.82 11.22 1.41 14.96 12.14 1.46 15.64 12.70 1.50 16.99 13.78 1.56 17.88 14.51 1.61 118 11.73 9.51 1.34 12.62 10.24 1.38 13.52 10.97 1.42 14.63 11.89 1.47 15.30 12.43 1.51 16.63 13.50 1.57 17.51 14.20 1.62 122 11.38 9.71 1.35 12.24 10.45 1.39 13.11 11.19 1.44 14.19 12.13 1.49 14.84 12.68 1.52 16.13 13.77 1.59 16.98 14.49 1.63 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] SHC : Sensible Heating Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. : Cooling range can be extended from 14 ℉ down to 0 ℉ using the Low Ambient Wind Baffle Kit (sold separately). 3. : Indicates reference data. When operating at this temperature, these values can be different by discontinuous operation. 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on the following conditions : - Interconnecting Piping Length 24.6 ft (7.5 m) - Level Difference of Zero. - Indoor Air Temperature : 80 ℉ (26.7 ℃) DB / 67 ℉ (19.4 ℃) WB - Outdoor Air Temperature : 95 ℉ (35.0 ℃) DB / 75 ℉ (23.9 ℃) WB Wall Mounted-60Hz(R410A) _ 34 Inverter Single Indoor Air Temperature : ℉DB / ℉WB Outdoor Air Temp. Inverter Single 8. Capacity Tables Inverter Single Model : M24CJ Indoor Air Temperature : ℉DB / ℉WB Outdoor Air Temp. ℉DB 64 / 53 TC SHC 68 / 57 PI TC SHC 72 / 61 PI TC SHC 77 / 64 PI TC SHC 80 / 67 PI TC SHC 86 / 72 PI TC SHC 90 / 75 PI TC SHC PI 0 13.32 9.29 0.79 16.66 9.89 0.94 19.99 10.49 1.08 24.16 11.24 1.26 26.66 11.69 1.37 22.25 12.75 1.12 19.30 13.46 0.95 5 13.07 9.15 0.83 16.34 9.75 0.98 19.61 10.34 1.13 23.70 11.08 1.32 26.15 11.53 1.44 21.82 12.57 1.17 18.93 13.27 1.00 7 13.16 9.24 0.84 16.45 9.84 0.99 19.74 10.44 1.15 23.86 11.18 1.34 26.33 11.63 1.45 21.97 12.69 1.18 19.06 13.39 1.01 10 13.29 9.37 0.85 16.62 9.97 1.01 19.95 10.58 1.16 24.10 11.34 1.36 26.60 11.79 1.48 22.20 12.86 1.20 19.26 13.57 1.02 14 13.47 9.53 0.87 16.84 10.15 1.03 20.22 10.77 1.19 24.43 11.54 1.39 26.96 12.01 1.51 22.50 13.09 1.23 19.52 13.82 1.04 23 14.46 10.24 0.86 17.40 10.90 1.04 20.33 11.56 1.22 24.00 12.39 1.44 26.20 12.88 1.58 23.06 14.06 1.26 20.96 14.84 1.04 25 14.69 10.40 0.88 17.56 11.04 1.06 20.43 11.68 1.23 24.02 12.49 1.45 26.18 12.97 1.58 23.31 14.21 1.28 21.40 15.03 1.07 30 15.25 10.80 0.95 17.97 11.39 1.11 20.68 11.99 1.27 24.08 12.73 1.47 26.11 13.18 1.59 23.94 14.58 1.33 22.50 15.52 1.15 35 15.82 11.20 1.01 18.38 11.75 1.16 20.94 12.29 1.31 24.13 12.97 1.49 26.05 13.38 1.61 24.58 14.96 1.38 23.60 16.02 1.23 40 16.39 11.60 1.08 18.79 12.10 1.21 21.19 12.60 1.35 24.19 13.22 1.52 25.99 13.59 1.62 25.21 15.34 1.43 24.70 16.51 1.30 45 16.96 12.00 1.14 19.20 12.45 1.26 21.44 12.90 1.39 24.24 13.46 1.54 25.93 13.80 1.63 25.85 15.72 1.48 25.79 17.00 1.38 50 17.52 12.41 1.20 19.61 12.81 1.31 21.69 13.21 1.42 24.30 13.71 1.56 25.86 14.01 1.64 26.48 16.10 1.53 26.89 17.49 1.46 55 18.09 12.81 1.27 20.02 13.16 1.37 21.95 13.51 1.46 24.36 13.95 1.58 25.80 14.22 1.66 27.12 16.47 1.58 27.99 17.98 1.53 60 18.66 13.21 1.33 20.43 13.51 1.42 22.20 13.82 1.50 24.41 14.20 1.61 25.74 14.42 1.67 27.75 16.85 1.63 29.09 18.47 1.61 65 18.49 13.09 1.40 20.17 13.46 1.48 21.85 13.83 1.56 23.95 14.29 1.66 25.21 14.56 1.72 27.21 16.86 1.71 28.55 18.39 1.69 70 18.32 12.97 1.47 19.91 13.40 1.55 21.50 13.84 1.62 23.48 14.38 1.72 24.67 14.70 1.78 26.68 16.87 1.78 28.02 18.32 1.78 75 18.15 12.85 1.54 19.65 13.35 1.61 21.14 13.85 1.68 23.01 14.47 1.77 24.14 14.84 1.83 26.14 16.88 1.85 27.48 18.24 1.86 80 17.98 12.73 1.60 19.39 13.29 1.67 20.79 13.86 1.74 22.55 14.56 1.83 23.60 14.98 1.88 25.61 16.89 1.92 26.94 18.16 1.94 85 17.81 12.61 1.67 19.12 13.24 1.74 20.44 13.87 1.80 22.08 14.65 1.88 23.07 15.12 1.93 25.07 16.90 1.99 26.40 18.09 2.03 90 17.64 12.49 1.74 18.86 13.19 1.80 20.09 13.88 1.86 21.62 14.74 1.94 22.53 15.26 1.99 24.53 16.91 2.06 25.87 18.01 2.11 95 17.47 12.37 1.81 18.60 13.13 1.87 19.74 13.89 1.92 21.15 14.83 2.00 22.00 15.40 2.04 24.00 16.92 2.13 25.33 17.93 2.19 100 17.01 12.05 1.84 18.17 12.84 1.89 19.34 13.63 1.95 20.79 14.62 2.03 21.66 15.22 2.07 23.58 16.65 2.16 24.87 17.61 2.22 105 16.56 11.72 1.86 17.75 12.55 1.92 18.94 13.38 1.98 20.42 14.41 2.06 21.31 15.03 2.10 23.17 16.38 2.19 24.41 17.28 2.25 110 16.10 11.40 1.89 17.32 12.26 1.95 18.54 13.12 2.01 20.06 14.20 2.09 20.97 14.85 2.13 22.76 16.11 2.22 23.95 16.96 2.28 115 15.53 10.99 1.91 16.70 11.83 1.97 17.88 12.67 2.03 19.35 13.72 2.11 20.24 14.35 2.15 21.98 15.57 2.25 23.14 16.39 2.31 118 15.18 10.75 1.92 16.34 11.57 1.98 17.49 12.40 2.05 18.93 13.43 2.12 19.80 14.05 2.17 21.52 15.24 2.26 22.66 16.04 2.33 122 14.72 10.96 1.94 15.84 11.80 2.00 16.97 12.64 2.07 18.37 13.70 2.14 19.21 14.33 2.19 20.87 15.55 2.29 21.98 16.36 2.35 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] SHC : Sensible Heating Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) 35 _ Wall Mounted-60Hz(R410A) Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. : Cooling range can be extended from 14 ℉ down to 0 ℉ using the Low Ambient Wind Baffle Kit (sold separately). 3. : Indicates reference data. When operating at this temperature, these values can be different by discontinuous operation. 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on the following conditions : - Interconnecting Piping Length 24.6 ft (7.5 m) - Level Difference of Zero. - Indoor Air Temperature : 80 ℉ (26.7 ℃) DB / 67 ℉ (19.4 ℃) WB - Outdoor Air Temperature : 95 ℉ (35.0 ℃) DB / 75 ℉ (23.9 ℃) WB Inverter Single 8. Capacity Tables Model : M09YJ ℉DB 64 / 53 TC SHC 68 / 57 PI TC SHC 72 / 61 PI TC SHC 77 / 64 PI TC SHC 80 / 67 PI TC SHC 86 / 72 PI TC SHC 90 / 75 PI TC SHC PI 0 0.54 0.45 0.26 0.68 0.48 0.31 0.82 0.51 0.36 0.99 0.54 0.42 1.09 0.56 0.46 0.91 0.62 0.37 0.79 0.65 0.32 5 0.53 0.44 0.28 0.67 0.47 0.33 0.80 0.50 0.38 0.97 0.53 0.44 1.07 0.56 0.48 0.89 0.61 0.39 0.77 0.64 0.33 7 0.54 0.45 0.28 0.67 0.47 0.33 0.81 0.50 0.38 0.98 0.54 0.44 1.08 0.56 0.48 0.90 0.61 0.39 0.78 0.65 0.33 10 0.54 0.45 0.28 0.68 0.48 0.33 0.82 0.51 0.39 0.99 0.55 0.45 1.09 0.57 0.49 0.91 0.62 0.40 0.79 0.66 0.34 14 0.55 0.46 0.29 0.69 0.49 0.34 0.83 0.52 0.39 1.00 0.56 0.46 1.10 0.58 0.50 0.92 0.63 0.41 0.80 0.67 0.35 23 0.59 0.49 0.28 0.71 0.53 0.34 0.83 0.56 0.40 0.98 0.60 0.48 1.07 0.62 0.52 0.94 0.68 0.42 0.86 0.72 0.35 25 0.60 0.50 0.29 0.72 0.53 0.35 0.84 0.56 0.41 0.98 0.60 0.48 1.07 0.63 0.52 0.95 0.69 0.42 0.88 0.73 0.36 30 0.62 0.52 0.31 0.74 0.55 0.37 0.85 0.58 0.42 0.98 0.61 0.49 1.07 0.64 0.53 0.98 0.70 0.44 0.92 0.75 0.38 35 0.65 0.54 0.34 0.75 0.57 0.39 0.86 0.59 0.43 0.99 0.63 0.50 1.07 0.65 0.53 1.01 0.72 0.46 0.97 0.77 0.41 40 0.67 0.56 0.36 0.77 0.58 0.40 0.87 0.61 0.45 0.99 0.64 0.50 1.06 0.66 0.54 1.03 0.74 0.47 1.01 0.80 0.43 45 0.69 0.58 0.38 0.79 0.60 0.42 0.88 0.62 0.46 0.99 0.65 0.51 1.06 0.67 0.54 1.06 0.76 0.49 1.06 0.82 0.46 50 0.72 0.60 0.40 0.80 0.62 0.44 0.89 0.64 0.47 0.99 0.66 0.52 1.06 0.68 0.55 1.08 0.78 0.51 1.10 0.84 0.48 55 0.74 0.62 0.42 0.82 0.64 0.45 0.90 0.65 0.49 1.00 0.67 0.53 1.06 0.69 0.55 1.11 60 0.76 0.64 0.44 0.84 0.65 0.47 0.91 0.67 0.50 1.00 0.69 0.53 1.05 0.70 0.55 1.14 0.81 0.54 1.19 0.89 0.53 65 0.76 0.63 0.46 0.83 0.65 0.49 0.89 0.67 0.52 0.98 0.69 0.55 1.03 0.70 0.57 1.11 70 0.75 0.63 0.49 0.81 0.65 0.51 0.88 0.67 0.54 0.96 0.69 0.57 1.01 0.71 0.59 1.09 0.81 0.59 1.15 0.88 0.59 75 0.74 0.62 0.51 0.80 0.64 0.53 0.86 0.67 0.56 0.94 0.70 0.59 0.99 0.72 0.61 1.07 0.81 0.61 1.12 0.88 0.62 80 0.74 0.61 0.53 0.79 0.64 0.56 0.85 0.67 0.58 0.92 0.70 0.61 0.97 0.72 0.62 1.05 0.82 0.64 1.10 0.88 0.64 85 0.73 0.61 0.56 0.78 0.64 0.58 0.84 0.67 0.60 0.90 0.71 0.63 0.94 0.73 0.64 1.03 0.82 0.66 1.08 0.87 0.67 90 0.72 0.60 0.58 0.77 0.64 0.60 0.82 0.67 0.62 0.88 0.71 0.64 0.92 0.74 0.66 1.00 0.82 0.68 1.06 0.87 0.70 0.80 0.53 1.15 0.87 0.51 0.81 0.57 1.17 0.89 0.56 95 0.71 0.60 0.60 0.76 0.63 0.62 0.81 0.67 0.64 0.87 0.72 0.66 0.90 0.74 0.68 0.98 0.82 0.71 1.04 0.87 0.73 100 0.70 0.58 0.61 0.74 0.62 0.63 0.79 0.66 0.65 0.85 0.71 0.67 0.89 0.73 0.69 0.96 0.80 0.72 1.02 0.85 0.74 105 0.68 0.57 0.62 0.73 0.61 0.64 0.77 0.65 0.66 0.84 0.70 0.68 0.87 0.73 0.70 0.95 0.79 0.73 1.00 0.83 0.75 110 0.66 0.55 0.63 0.71 0.59 0.65 0.76 0.63 0.67 0.82 0.69 0.69 0.86 0.72 0.71 0.93 0.78 0.74 0.98 0.82 0.76 115 0.64 0.53 0.63 0.68 0.57 0.65 0.73 0.61 0.67 0.79 0.66 0.70 0.83 0.69 0.71 0.90 0.75 0.75 0.95 0.79 0.77 118 0.62 0.52 0.64 0.67 0.56 0.66 0.72 0.60 0.68 0.77 0.65 0.70 0.81 0.68 0.72 0.88 0.74 0.75 0.93 0.77 0.77 122 0.60 0.53 0.64 0.65 0.57 0.67 0.69 0.61 0.69 0.75 0.66 0.71 0.79 0.69 0.73 0.85 0.75 0.76 0.90 0.79 0.78 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] SHC : Sensible Heating Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. : Cooling range can be extended from 14 ℉ down to 0 ℉ using the Low Ambient Wind Baffle Kit (sold separately). 3. : Indicates reference data. When operating at this temperature, these values can be different by discontinuous operation. 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on the following conditions : - Interconnecting Piping Length 24.6 ft (7.5 m) - Level Difference of Zero. - Indoor Air Temperature : 80 ℉ (26.7 ℃) DB / 67 ℉ (19.4 ℃) WB - Outdoor Air Temperature : 95 ℉ (35.0 ℃) DB / 75 ℉ (23.9 ℃) WB Wall Mounted-60Hz(R410A) _ 36 Inverter Single Indoor Air Temperature : ℉DB / ℉WB Outdoor Air Temp. Inverter Single 8. Capacity Tables Inverter Single Model : M12YJ Indoor Air Temperature : ℉DB / ℉WB Outdoor Air Temp. ℉DB 64 / 53 TC SHC 68 / 57 PI TC SHC 72 / 61 PI TC SHC 77 / 64 PI TC SHC 80 / 67 PI TC SHC 86 / 72 PI TC SHC 90 / 75 PI TC SHC PI 0 6.78 5.44 0.35 8.48 5.79 0.41 10.18 6.14 0.48 12.30 6.58 0.56 13.57 6.85 0.60 11.33 7.47 0.49 9.83 7.88 0.42 5 6.65 5.36 0.36 8.32 5.71 0.43 9.98 6.05 0.50 12.06 6.49 0.58 13.31 6.75 0.63 11.11 7.36 0.51 9.64 7.77 0.44 7 6.70 5.41 0.37 8.37 5.76 0.44 10.05 6.11 0.50 12.15 6.55 0.59 13.40 6.81 0.64 11.18 7.43 0.52 9.71 7.84 0.44 10 6.77 5.48 0.37 8.46 5.84 0.44 10.15 6.19 0.51 12.27 6.64 0.60 13.54 6.90 0.65 11.30 7.53 0.53 9.80 7.95 0.45 14 6.86 5.58 0.38 8.57 5.94 0.45 10.29 6.31 0.52 12.44 6.76 0.61 13.73 7.03 0.66 11.45 7.66 0.54 9.94 8.09 0.46 23 7.36 5.99 0.38 8.86 6.38 0.46 10.35 6.77 0.53 12.22 7.25 0.63 13.34 7.54 0.69 11.74 8.23 0.55 10.67 8.69 0.46 25 7.48 6.09 0.39 8.94 6.46 0.46 10.40 6.84 0.54 12.23 7.31 0.64 13.33 7.59 0.69 11.87 8.32 0.56 10.89 8.80 0.47 30 7.77 6.32 0.42 9.15 6.67 0.49 10.53 7.02 0.56 12.26 7.45 0.65 13.29 7.71 0.70 12.19 8.54 0.58 11.45 9.09 0.51 35 8.05 6.56 0.44 9.36 6.88 0.51 10.66 7.20 0.57 12.29 7.60 0.66 13.26 7.84 0.71 12.51 8.76 0.61 12.01 9.38 0.54 40 8.34 6.79 0.47 9.57 7.08 0.53 10.79 7.38 0.59 12.31 7.74 0.67 13.23 7.96 0.71 12.84 8.98 0.63 12.57 9.66 0.57 45 8.63 7.03 0.50 9.77 7.29 0.55 10.92 7.55 0.61 12.34 7.88 0.68 13.20 8.08 0.72 13.16 9.20 0.65 13.13 9.95 0.61 50 8.92 7.26 0.53 9.98 7.50 0.58 11.04 7.73 0.63 12.37 8.03 0.69 13.17 8.20 0.72 13.48 9.42 0.67 13.69 10.24 0.64 55 9.21 7.50 0.56 10.19 7.70 0.60 11.17 7.91 0.64 12.40 8.17 0.70 13.14 8.32 0.73 13.80 9.64 0.70 14.25 10.53 0.67 60 9.50 7.73 0.59 10.40 7.91 0.62 11.30 8.09 0.66 12.43 8.31 0.71 13.10 8.44 0.73 14.13 9.87 0.72 14.81 10.81 0.71 65 9.41 7.66 0.62 10.27 7.88 0.65 11.12 8.10 0.69 12.19 8.36 0.73 12.83 8.53 0.76 13.85 9.87 0.75 14.54 10.77 0.74 70 9.33 7.59 0.65 10.13 7.85 0.68 10.94 8.10 0.71 11.95 8.42 0.75 12.56 8.61 0.78 13.58 9.88 0.78 14.26 10.72 0.78 75 9.24 7.52 0.67 10.00 7.82 0.71 10.76 8.11 0.74 11.72 8.47 0.78 12.29 8.69 0.80 13.31 9.88 0.81 13.99 10.68 0.82 80 9.15 7.45 0.70 9.87 7.78 0.74 10.58 8.11 0.77 11.48 8.52 0.80 12.02 8.77 0.83 13.04 9.89 0.84 13.72 10.63 0.85 85 9.07 7.38 0.73 9.74 7.75 0.76 10.41 8.12 0.79 11.24 8.58 0.83 11.74 8.85 0.85 12.76 9.89 0.87 13.44 10.59 0.89 90 8.98 7.31 0.76 9.60 7.72 0.79 10.23 8.12 0.82 11.00 8.63 0.85 11.47 8.93 0.87 12.49 9.90 0.90 13.17 10.54 0.93 95 8.89 7.24 0.79 9.47 7.69 0.82 10.05 8.13 0.85 10.77 8.68 0.88 11.20 9.02 0.90 12.22 9.91 0.94 12.90 10.50 0.96 100 8.66 7.05 0.81 9.25 7.52 0.83 9.84 7.98 0.86 10.58 8.56 0.89 11.03 8.91 0.91 12.01 9.75 0.95 12.66 10.31 0.98 105 8.43 6.86 0.82 9.03 7.35 0.84 9.64 7.83 0.87 10.40 8.44 0.90 10.85 8.80 0.92 11.80 9.59 0.96 12.43 10.12 0.99 110 8.20 6.67 0.83 8.82 7.18 0.86 9.44 7.68 0.88 10.21 8.31 0.92 10.68 8.69 0.94 11.59 9.43 0.98 12.19 9.93 1.00 115 7.90 6.44 0.84 8.50 6.93 0.87 9.10 7.42 0.89 9.85 8.03 0.93 10.30 8.40 0.95 11.19 9.12 0.99 11.78 9.59 1.02 118 7.73 6.29 0.85 8.32 6.77 0.87 8.90 7.26 0.90 9.64 7.86 0.93 10.08 8.22 0.95 10.95 8.92 0.99 11.54 9.39 1.02 122 7.50 6.42 0.85 8.07 6.91 0.88 8.64 7.40 0.91 9.35 8.02 0.94 9.78 8.39 0.96 10.62 9.10 1.00 11.19 9.58 1.03 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] SHC : Sensible Heating Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) 37 _ Wall Mounted-60Hz(R410A) Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. : Cooling range can be extended from 14 ℉ down to 0 ℉ using the Low Ambient Wind Baffle Kit (sold separately). 3. : Indicates reference data. When operating at this temperature, these values can be different by discontinuous operation. 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on the following conditions : - Interconnecting Piping Length 24.6 ft (7.5 m) - Level Difference of Zero. - Indoor Air Temperature : 80 ℉ (26.7 ℃) DB / 67 ℉ (19.4 ℃) WB - Outdoor Air Temperature : 95 ℉ (35.0 ℃) DB / 75 ℉ (23.9 ℃) WB Inverter Single 8. Capacity Tables Model : M18YJ ℉DB 64 / 53 TC SHC 68 / 57 PI TC SHC 72 / 61 PI TC SHC 77 / 64 PI TC SHC 80 / 67 PI TC SHC 86 / 72 PI TC SHC 90 / 75 PI TC SHC PI 0 10.29 8.25 0.55 12.87 8.79 0.65 15.45 9.32 0.75 18.67 9.99 0.88 20.60 10.39 0.95 17.19 11.33 0.78 14.92 11.96 0.66 5 10.10 8.13 0.58 12.62 8.66 0.68 15.15 9.19 0.79 18.31 9.85 0.92 20.21 10.24 1.00 16.86 11.17 0.81 14.63 11.79 0.69 7 10.17 8.21 0.58 12.71 8.74 0.69 15.26 9.27 0.80 18.44 9.94 0.93 20.35 10.34 1.01 16.98 11.27 0.82 14.73 11.90 0.70 10 10.27 8.32 0.59 12.84 8.86 0.70 15.41 9.40 0.81 18.63 10.07 0.94 20.55 10.48 1.03 17.15 11.43 0.84 14.88 12.06 0.71 14 10.41 8.47 0.60 13.01 9.02 0.71 15.62 9.57 0.83 18.88 10.26 0.96 20.83 10.67 1.05 17.38 11.63 0.85 15.08 12.28 0.72 23 11.17 9.10 0.60 13.44 9.69 0.72 15.71 10.27 0.85 18.54 11.01 1.00 20.25 11.45 1.09 17.82 12.49 0.87 16.20 13.18 0.72 25 11.35 9.24 0.61 13.57 9.81 0.73 15.79 10.38 0.86 18.56 11.10 1.01 20.23 11.52 1.10 18.01 12.63 0.89 16.54 13.36 0.75 30 11.79 9.60 0.66 13.89 10.12 0.77 15.98 10.65 0.88 18.60 11.31 1.02 20.18 11.71 1.11 18.50 12.96 0.92 17.38 13.80 0.80 35 12.23 9.95 0.70 14.20 10.44 0.81 16.18 10.92 0.91 18.65 11.53 1.04 20.13 11.89 1.12 18.99 13.30 0.96 18.23 14.23 0.85 40 12.66 10.31 0.75 14.52 10.75 0.84 16.37 11.19 0.94 18.69 11.75 1.05 20.08 12.08 1.12 19.48 13.63 0.99 19.08 14.67 0.91 45 13.10 10.67 0.79 14.84 11.07 0.88 16.57 11.47 0.96 18.73 11.96 1.07 20.03 12.26 1.13 19.97 13.97 1.03 19.93 15.10 0.96 50 13.54 11.02 0.84 15.15 11.38 0.91 16.76 11.74 0.99 18.78 12.18 1.08 19.99 12.45 1.14 20.46 14.30 1.06 20.78 15.54 1.01 55 13.98 11.38 0.88 15.47 11.69 0.95 16.96 12.01 1.02 18.82 12.40 1.10 19.94 12.63 1.15 20.95 14.64 1.10 21.63 15.98 1.07 60 14.42 11.74 0.93 15.79 12.01 0.98 17.15 12.28 1.04 18.86 12.62 1.12 19.89 12.82 1.16 21.44 14.97 1.14 22.48 16.41 1.12 65 14.29 11.63 0.97 15.59 11.96 1.03 16.88 12.29 1.08 18.50 12.70 1.15 19.48 12.94 1.20 21.03 14.98 1.18 22.06 16.34 1.18 70 14.16 11.53 1.02 15.38 11.91 1.07 16.61 12.30 1.13 18.14 12.78 1.19 19.06 13.07 1.23 20.61 14.99 1.23 21.65 16.28 1.23 75 14.03 11.42 1.07 15.18 11.86 1.12 16.34 12.31 1.17 17.78 12.86 1.23 18.65 13.19 1.27 20.20 15.00 1.28 21.23 16.21 1.29 80 13.89 11.31 1.11 14.98 11.81 1.16 16.07 12.31 1.21 17.42 12.94 1.27 18.24 13.31 1.31 19.79 15.01 1.33 20.82 16.14 1.35 85 13.76 11.21 1.16 14.78 11.77 1.21 15.79 12.32 1.25 17.06 13.02 1.31 17.83 13.44 1.34 19.37 15.02 1.38 20.40 16.07 1.41 90 13.63 11.10 1.21 14.58 11.72 1.25 15.52 12.33 1.29 16.70 13.10 1.35 17.41 13.56 1.38 18.96 15.03 1.43 19.99 16.00 1.46 95 13.50 11.00 1.26 14.37 11.67 1.30 15.25 12.34 1.34 16.34 13.18 1.39 17.00 13.69 1.42 18.54 15.04 1.48 19.57 15.94 1.52 100 13.15 10.71 1.27 14.04 11.41 1.32 14.94 12.11 1.36 16.06 12.99 1.41 16.73 13.52 1.44 18.22 14.80 1.50 19.22 15.65 1.54 105 12.79 10.42 1.29 13.71 11.15 1.34 14.63 11.89 1.38 15.78 12.81 1.43 16.47 13.36 1.46 17.91 14.56 1.52 18.86 15.36 1.56 110 12.44 10.13 1.31 13.38 10.89 1.35 14.32 11.66 1.40 15.50 12.62 1.45 16.20 13.19 1.48 17.59 14.32 1.54 18.51 15.07 1.59 115 12.00 9.77 1.33 12.91 10.51 1.37 13.82 11.26 1.41 14.96 12.19 1.46 15.64 12.75 1.50 16.99 13.84 1.56 17.88 14.56 1.61 118 11.73 9.55 1.34 12.62 10.28 1.38 13.52 11.02 1.42 14.63 11.93 1.47 15.30 12.48 1.51 16.63 13.55 1.57 17.51 14.26 1.62 122 11.38 9.74 1.35 12.24 10.49 1.39 13.11 11.24 1.44 14.19 12.17 1.49 14.84 12.73 1.52 16.13 13.82 1.59 16.98 14.54 1.63 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] SHC : Sensible Heating Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. : Cooling range can be extended from 14 ℉ down to 0 ℉ using the Low Ambient Wind Baffle Kit (sold separately). 3. : Indicates reference data. When operating at this temperature, these values can be different by discontinuous operation. 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on the following conditions : - Interconnecting Piping Length 24.6 ft (7.5 m) - Level Difference of Zero. - Indoor Air Temperature : 80 ℉ (26.7 ℃) DB / 67 ℉ (19.4 ℃) WB - Outdoor Air Temperature : 95 ℉ (35.0 ℃) DB / 75 ℉ (23.9 ℃) WB Wall Mounted-60Hz(R410A) _ 38 Inverter Single Indoor Air Temperature : ℉DB / ℉WB Outdoor Air Temp. Inverter Single 8. Capacity Tables Inverter Single Model : M24YJ Indoor Air Temperature : ℉DB / ℉WB Outdoor Air Temp. ℉DB 64 / 53 TC SHC 68 / 57 PI TC SHC 72 / 61 PI TC SHC 77 / 64 PI TC SHC 80 / 67 PI TC SHC 86 / 72 PI TC SHC 90 / 75 PI TC SHC PI 0 13.32 10.27 0.68 16.66 10.93 0.81 19.99 11.60 0.93 24.16 12.43 1.09 26.66 12.93 1.19 22.25 14.10 0.97 19.30 14.88 0.82 5 13.07 10.12 0.72 16.34 10.78 0.85 19.61 11.43 0.98 23.70 12.25 1.14 26.15 12.75 1.24 21.82 13.90 1.01 18.93 14.67 0.86 7 13.16 10.22 0.72 16.45 10.88 0.86 19.74 11.54 0.99 23.86 12.37 1.15 26.33 12.86 1.25 21.97 14.03 1.02 19.06 14.80 0.87 10 13.29 10.36 0.73 16.62 11.03 0.87 19.95 11.70 1.00 24.10 12.54 1.17 26.60 13.04 1.27 22.20 14.22 1.04 19.26 15.01 0.88 14 13.47 10.54 0.75 16.84 11.22 0.89 20.22 11.91 1.03 24.43 12.76 1.20 26.96 13.27 1.30 22.50 14.48 1.06 19.52 15.28 0.90 23 14.46 11.32 0.74 17.40 12.05 0.90 20.33 12.78 1.05 24.00 13.70 1.24 26.20 14.25 1.36 23.06 15.54 1.08 20.96 16.41 0.90 25 14.69 11.50 0.76 17.56 12.21 0.91 20.43 12.92 1.06 24.02 13.81 1.25 26.18 14.34 1.36 23.31 15.71 1.10 21.40 16.62 0.93 30 15.25 11.94 0.82 17.97 12.60 0.96 20.68 13.26 1.10 24.08 14.08 1.27 26.11 14.57 1.38 23.94 16.13 1.15 22.50 17.17 0.99 35 15.82 12.39 0.87 18.38 12.99 1.00 20.94 13.59 1.13 24.13 14.35 1.29 26.05 14.80 1.39 24.58 16.54 1.19 23.60 17.71 1.06 40 16.39 12.83 0.93 18.79 13.38 1.05 21.19 13.93 1.16 24.19 14.62 1.31 25.99 15.03 1.40 25.21 16.96 1.23 24.70 18.25 1.13 45 16.96 13.27 0.98 19.20 13.77 1.09 21.44 14.27 1.20 24.24 14.89 1.33 25.93 15.26 1.41 25.85 17.38 1.28 25.79 18.79 1.19 50 17.52 13.72 1.04 19.61 14.16 1.13 21.69 14.60 1.23 24.30 15.16 1.35 25.86 15.49 1.42 26.48 17.80 1.32 26.89 19.34 1.26 55 18.09 14.16 1.09 20.02 14.55 1.18 21.95 14.94 1.26 24.36 15.43 1.37 25.80 15.72 1.43 27.12 18.21 1.37 27.99 19.88 1.32 60 18.66 14.61 1.15 20.43 14.94 1.22 22.20 15.28 1.30 24.41 15.70 1.39 25.74 15.95 1.44 27.75 18.63 1.41 29.09 20.42 1.39 65 18.49 14.47 1.21 20.17 14.88 1.28 21.85 15.29 1.35 23.95 15.80 1.43 25.21 16.10 1.49 27.21 18.64 1.47 28.55 20.34 1.46 70 18.32 14.34 1.27 19.91 14.82 1.33 21.50 15.30 1.40 23.48 15.90 1.48 24.67 16.26 1.53 26.68 18.65 1.53 28.02 20.25 1.53 75 18.15 14.21 1.33 19.65 14.76 1.39 21.14 15.31 1.45 23.01 16.00 1.53 24.14 16.41 1.58 26.14 18.67 1.59 27.48 20.17 1.60 80 17.98 14.08 1.38 19.39 14.70 1.44 20.79 15.32 1.50 22.55 16.10 1.58 23.60 16.57 1.62 25.61 18.68 1.65 26.94 20.08 1.68 85 17.81 13.95 1.44 19.12 14.64 1.50 20.44 15.33 1.56 22.08 16.20 1.63 23.07 16.72 1.67 25.07 18.69 1.72 26.40 20.00 1.75 90 17.64 13.81 1.50 18.86 14.58 1.55 20.09 15.34 1.61 21.62 16.30 1.67 22.53 16.87 1.71 24.53 18.70 1.78 25.87 19.91 1.82 95 17.47 13.68 1.56 18.60 14.52 1.61 19.74 15.36 1.66 21.15 16.40 1.72 22.00 17.03 1.76 24.00 18.71 1.84 25.33 19.83 1.89 100 17.01 13.32 1.58 18.17 14.20 1.63 19.34 15.07 1.69 20.79 16.17 1.75 21.66 16.82 1.79 23.58 18.41 1.86 24.87 19.47 1.92 105 16.56 12.96 1.61 17.75 13.88 1.66 18.94 14.79 1.71 20.42 15.93 1.77 21.31 16.62 1.81 23.17 18.11 1.89 24.41 19.11 1.94 110 16.10 12.60 1.63 17.32 13.56 1.68 18.54 14.51 1.74 20.06 15.70 1.80 20.97 16.42 1.84 22.76 17.82 1.92 23.95 18.75 1.97 115 15.53 12.15 1.65 16.70 13.08 1.70 17.88 14.01 1.75 19.35 15.17 1.82 20.24 15.86 1.86 21.98 17.22 1.94 23.14 18.12 2.00 118 15.18 11.88 1.66 16.34 12.80 1.71 17.49 13.71 1.77 18.93 14.85 1.83 19.80 15.53 1.87 21.52 16.85 1.95 22.66 17.74 2.01 122 14.72 12.12 1.68 15.84 13.05 1.73 16.97 13.98 1.78 18.37 15.14 1.85 19.21 15.84 1.89 20.87 17.19 1.97 21.98 18.09 2.03 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] SHC : Sensible Heating Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) 39 _ Wall Mounted-60Hz(R410A) Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. : Cooling range can be extended from 14 ℉ down to 0 ℉ using the Low Ambient Wind Baffle Kit (sold separately). 3. : Indicates reference data. When operating at this temperature, these values can be different by discontinuous operation. 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on the following conditions : - Interconnecting Piping Length 24.6 ft (7.5 m) - Level Difference of Zero. - Indoor Air Temperature : 80 ℉ (26.7 ℃) DB / 67 ℉ (19.4 ℃) WB - Outdoor Air Temperature : 95 ℉ (35.0 ℃) DB / 75 ℉ (23.9 ℃) WB Inverter Single 8. Capacity Tables Model : M30YJ ℉DB 64 / 53 TC SHC 68 / 57 PI TC SHC 72 / 61 PI TC SHC 77 / 64 PI TC SHC 80 / 67 PI TC SHC 86 / 72 PI TC SHC 90 / 75 PI TC SHC PI 0 18.16 14.00 1.17 22.71 14.91 1.38 27.26 15.82 1.59 32.94 16.95 1.86 36.35 17.63 2.02 30.34 19.23 1.65 26.32 20.29 1.40 5 17.82 13.80 1.22 22.28 14.70 1.44 26.74 15.59 1.67 32.31 16.71 1.95 35.66 17.38 2.11 29.75 18.95 1.72 25.82 20.00 1.46 7 17.94 13.93 1.23 22.43 14.83 1.46 26.92 15.74 1.68 32.54 16.86 1.97 35.90 17.54 2.14 29.96 19.13 1.74 26.00 20.19 1.48 10 18.12 14.12 1.25 22.66 15.04 1.48 27.20 15.95 1.71 32.87 17.09 2.00 36.27 17.78 2.17 30.27 19.39 1.77 26.26 20.46 1.50 14 18.37 14.37 1.28 22.97 15.31 1.51 27.57 16.24 1.75 33.31 17.40 2.04 36.76 18.10 2.22 30.68 19.74 1.81 26.62 20.83 1.53 23 19.72 15.44 1.26 23.72 16.43 1.53 27.72 17.43 1.79 32.73 18.68 2.12 35.73 19.43 2.32 31.44 21.19 1.85 28.58 22.37 1.53 25 20.03 15.68 1.30 23.94 16.65 1.56 27.86 17.62 1.81 32.76 18.83 2.13 35.69 19.55 2.33 31.79 21.42 1.88 29.18 22.67 1.58 30 20.80 16.28 1.39 24.50 17.18 1.63 28.21 18.08 1.87 32.83 19.19 2.17 35.61 19.87 2.34 32.65 21.99 1.95 30.68 23.41 1.69 35 21.58 16.89 1.49 25.06 17.71 1.71 28.55 18.53 1.93 32.91 19.56 2.20 35.52 20.18 2.36 33.52 22.56 2.03 32.18 24.15 1.80 40 22.35 17.50 1.58 25.62 18.24 1.78 28.89 18.99 1.98 32.98 19.93 2.23 35.44 20.49 2.38 34.38 23.13 2.10 33.68 24.89 1.92 45 23.12 18.10 1.68 26.18 18.78 1.86 29.24 19.45 2.04 33.06 20.30 2.26 35.35 20.81 2.40 35.25 23.70 2.18 35.17 25.63 2.03 50 23.90 18.71 1.77 26.74 19.31 1.93 29.58 19.91 2.09 33.14 20.67 2.30 35.27 21.12 2.42 36.11 24.27 2.25 36.67 26.37 2.14 55 24.67 19.31 1.87 27.30 19.84 2.01 29.93 20.37 2.15 33.21 21.04 2.33 35.18 21.43 2.44 36.98 24.84 2.33 38.17 27.11 2.26 60 25.45 19.92 1.96 27.86 20.38 2.08 30.27 20.83 2.21 33.29 21.40 2.36 35.10 21.75 2.45 37.84 25.41 2.40 39.67 27.85 2.37 65 25.21 19.74 2.06 27.50 20.29 2.18 29.79 20.85 2.30 32.65 21.54 2.44 34.37 21.96 2.53 37.11 25.42 2.51 38.94 27.73 2.49 70 24.98 19.56 2.16 27.15 20.21 2.27 29.31 20.86 2.39 32.02 21.68 2.53 33.64 22.17 2.61 36.38 25.44 2.61 38.20 27.62 2.61 75 24.75 19.38 2.26 26.79 20.13 2.37 28.83 20.88 2.47 31.38 21.82 2.61 32.91 22.38 2.69 35.65 25.45 2.72 37.47 27.50 2.73 80 24.52 19.20 2.36 26.44 20.05 2.46 28.35 20.89 2.56 30.75 21.95 2.69 32.19 22.59 2.77 34.92 25.47 2.82 36.74 27.39 2.86 85 24.29 19.02 2.46 26.08 19.96 2.56 27.87 20.91 2.65 30.11 22.09 2.77 31.46 22.80 2.84 34.19 25.48 2.92 36.01 27.27 2.98 90 24.05 18.84 2.56 25.72 19.88 2.65 27.39 20.92 2.74 29.48 22.23 2.85 30.73 23.01 2.92 33.46 25.50 3.03 35.27 27.15 3.10 95 23.82 18.66 2.66 25.37 19.80 2.74 26.91 20.94 2.83 28.84 22.36 2.94 30.00 23.22 3.00 32.72 25.51 3.13 34.54 27.04 3.22 100 23.20 18.17 2.70 24.78 19.36 2.79 26.37 20.55 2.87 28.34 22.05 2.98 29.53 22.94 3.05 32.16 25.11 3.18 33.91 26.55 3.27 105 22.58 17.68 2.74 24.20 18.92 2.83 25.82 20.17 2.91 27.85 21.73 3.02 29.06 22.66 3.09 31.60 24.70 3.22 33.29 26.06 3.31 110 21.95 17.19 2.78 23.61 18.49 2.87 25.28 19.79 2.96 27.35 21.41 3.07 28.60 22.38 3.14 31.03 24.29 3.27 32.66 25.57 3.36 115 21.17 16.57 2.81 22.78 17.84 2.90 24.38 19.10 2.99 26.39 20.68 3.10 27.60 21.63 3.17 29.98 23.48 3.31 31.56 24.71 3.40 118 20.70 16.20 2.83 22.28 17.45 2.92 23.85 18.69 3.01 25.82 20.25 3.12 27.00 21.18 3.19 29.34 22.98 3.33 30.90 24.19 3.43 122 20.08 16.53 2.86 21.61 17.80 2.95 23.13 19.07 3.04 25.04 20.65 3.15 26.19 21.60 3.22 28.46 23.44 3.36 29.97 24.67 3.46 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] SHC : Sensible Heating Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. : Cooling range can be extended from 14 ℉ down to 0 ℉ using the Low Ambient Wind Baffle Kit (sold separately). 3. : Indicates reference data. When operating at this temperature, these values can be different by discontinuous operation. 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on the following conditions : - Interconnecting Piping Length 24.6 ft (7.5 m) - Level Difference of Zero. - Indoor Air Temperature : 80 ℉ (26.7 ℃) DB / 67 ℉ (19.4 ℃) WB - Outdoor Air Temperature : 95 ℉ (35.0 ℃) DB / 75 ℉ (23.9 ℃) WB Wall Mounted-60Hz(R410A) _ 40 Inverter Single Indoor Air Temperature : ℉DB / ℉WB Outdoor Air Temp. Inverter Single 8. Capacity Tables Inverter Single Model : M36YJ Indoor Air Temperature : ℉DB / ℉WB Outdoor Air Temp. ℉DB 64 / 53 TC SHC 68 / 57 PI TC SHC 72 / 61 PI TC SHC 77 / 64 PI TC SHC 80 / 67 PI TC SHC 86 / 72 PI TC SHC 90 / 75 PI TC SHC PI 0 19.98 15.40 1.57 24.98 16.40 1.85 29.99 17.40 2.14 36.24 18.65 2.50 39.99 19.39 2.72 33.37 21.15 2.22 28.95 22.32 1.88 5 19.60 15.18 1.64 24.50 16.17 1.94 29.41 17.15 2.24 35.54 18.38 2.62 39.23 19.12 2.84 32.73 20.85 2.32 28.40 22.00 1.97 7 19.73 15.32 1.66 24.67 16.32 1.96 29.61 17.31 2.27 35.79 18.55 2.65 39.50 19.29 2.87 32.96 21.04 2.34 28.60 22.21 1.99 10 19.94 15.53 1.68 24.93 16.54 1.99 29.92 17.55 2.30 36.16 18.80 2.69 39.90 19.56 2.92 33.29 21.33 2.38 28.89 22.51 2.02 14 20.21 15.81 1.72 25.26 16.84 2.03 30.32 17.86 2.35 36.65 19.14 2.74 40.44 19.91 2.98 33.74 21.71 2.43 29.28 22.92 2.06 23 21.69 16.98 1.70 26.09 18.08 2.05 30.50 19.17 2.41 36.00 20.55 2.85 39.30 21.37 3.12 34.58 23.31 2.49 31.44 24.61 2.06 25 22.03 17.25 1.75 26.34 18.31 2.09 30.65 19.38 2.44 36.03 20.71 2.87 39.26 21.51 3.13 34.96 23.56 2.53 32.10 24.93 2.12 30 22.88 17.91 1.87 26.95 18.90 2.19 31.03 19.88 2.51 36.12 21.11 2.91 39.17 21.85 3.15 35.92 24.19 2.63 33.75 25.75 2.28 35 23.73 18.58 2.00 27.57 19.48 2.30 31.40 20.39 2.59 36.20 21.52 2.96 39.08 22.20 3.18 36.87 24.82 2.73 35.40 26.56 2.43 40 24.58 19.24 2.13 28.18 20.07 2.40 31.78 20.89 2.67 36.28 21.92 3.00 38.98 22.54 3.20 37.82 25.44 2.83 37.04 27.38 2.58 45 25.44 19.91 2.26 28.80 20.66 2.50 32.16 21.40 2.74 36.37 22.33 3.04 38.89 22.89 3.23 38.77 26.07 2.93 38.69 28.19 2.73 50 26.29 20.58 2.38 29.41 21.24 2.60 32.54 21.91 2.82 36.45 22.73 3.09 38.80 23.23 3.25 39.72 26.70 3.03 40.34 29.00 2.88 55 27.14 21.24 2.51 30.03 21.83 2.70 32.92 22.41 2.89 36.53 23.14 3.13 38.70 23.58 3.28 40.67 27.32 3.13 41.99 29.82 3.03 60 27.99 21.91 2.64 30.65 22.41 2.80 33.30 22.92 2.97 36.62 23.55 3.18 38.61 23.92 3.30 41.63 27.95 3.23 43.64 30.63 3.19 65 27.74 21.71 2.77 30.25 22.32 2.93 32.77 22.93 3.09 35.92 23.70 3.29 37.81 24.15 3.41 40.82 27.97 3.37 42.83 30.51 3.35 70 27.48 21.51 2.91 29.86 22.23 3.06 32.24 22.95 3.21 35.22 23.85 3.40 37.01 24.39 3.51 40.02 27.98 3.51 42.02 30.38 3.51 75 27.23 21.32 3.04 29.47 22.14 3.18 31.72 22.97 3.33 34.52 24.00 3.51 36.21 24.62 3.62 39.21 28.00 3.65 41.22 30.25 3.68 80 26.97 21.12 3.17 29.08 22.05 3.31 31.19 22.98 3.45 33.82 24.15 3.62 35.40 24.85 3.72 38.41 28.01 3.79 40.41 30.12 3.84 85 26.72 20.92 3.31 28.69 21.96 3.44 30.66 23.00 3.57 33.12 24.30 3.73 34.60 25.08 3.83 37.61 28.03 3.93 39.61 30.00 4.01 90 26.46 20.72 3.44 28.30 21.87 3.56 30.13 23.02 3.69 32.42 24.45 3.84 33.80 25.31 3.93 36.80 28.05 4.07 38.80 29.87 4.17 95 26.21 20.52 3.58 27.90 21.78 3.69 29.60 23.03 3.81 31.73 24.60 3.95 33.00 25.54 4.04 36.00 28.06 4.21 38.00 29.74 4.33 100 25.52 19.98 3.63 27.26 21.30 3.75 29.00 22.61 3.86 31.18 24.25 4.01 32.49 25.24 4.10 35.38 27.62 4.27 37.31 29.20 4.39 105 24.84 19.44 3.68 26.62 20.82 3.80 28.40 22.19 3.92 30.63 23.90 4.07 31.97 24.93 4.16 34.76 27.17 4.34 36.62 28.66 4.46 110 24.15 18.90 3.74 25.98 20.33 3.86 27.80 21.76 3.98 30.09 23.55 4.13 31.46 24.62 4.22 34.14 26.72 4.40 35.93 28.12 4.52 115 23.29 18.23 3.78 25.06 19.62 3.90 26.82 21.01 4.02 29.03 22.75 4.17 30.36 23.79 4.26 32.97 25.82 4.45 34.72 27.18 4.57 118 22.77 17.83 3.81 24.50 19.19 3.93 26.24 20.56 4.05 28.40 22.27 4.20 29.70 23.30 4.29 32.27 25.28 4.48 33.99 26.61 4.61 122 22.09 18.18 3.84 23.77 19.58 3.97 25.45 20.97 4.09 27.55 22.72 4.24 28.81 23.76 4.33 31.31 25.79 4.52 32.97 27.14 4.65 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] SHC : Sensible Heating Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) 41 _ Wall Mounted-60Hz(R410A) Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. : Cooling range can be extended from 14 ℉ down to 0 ℉ using the Low Ambient Wind Baffle Kit (sold separately). 3. : Indicates reference data. When operating at this temperature, these values can be different by discontinuous operation. 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on the following conditions : - Interconnecting Piping Length 24.6 ft (7.5 m) - Level Difference of Zero. - Indoor Air Temperature : 80 ℉ (26.7 ℃) DB / 67 ℉ (19.4 ℃) WB - Outdoor Air Temperature : 95 ℉ (35.0 ℃) DB / 75 ℉ (23.9 ℃) WB Inverter Single 8. Capacity Tables Model : HM12YJ ℉DB 64 / 53 TC SHC 68 / 57 PI TC SHC 72 / 61 PI TC SHC 77 / 64 PI TC SHC 80 / 67 PI TC SHC 86 / 72 PI TC SHC 90 / 75 PI TC SHC PI 14 7.35 6.46 0.37 9.19 6.88 0.43 11.03 7.30 0.50 13.33 7.82 0.58 14.71 8.14 0.63 12.27 8.88 0.52 10.65 9.37 0.44 23 7.89 6.94 0.36 9.49 7.39 0.44 11.09 7.84 0.51 13.09 8.40 0.61 14.29 8.73 0.66 12.58 9.53 0.53 11.43 10.06 0.44 25 8.01 7.05 0.37 9.58 7.48 0.44 11.14 7.92 0.52 13.10 8.46 0.61 14.28 8.79 0.66 12.71 9.63 0.54 11.67 10.19 0.45 30 8.32 7.32 0.40 9.80 7.72 0.47 11.28 8.13 0.53 13.13 8.63 0.62 14.24 8.93 0.67 13.06 9.89 0.56 12.27 10.52 0.48 35 8.63 7.59 0.43 10.03 7.96 0.49 11.42 8.33 0.55 13.16 8.80 0.63 14.21 9.07 0.67 13.41 10.14 0.58 12.87 10.86 0.52 40 8.94 7.87 0.45 10.25 8.20 0.51 11.56 8.54 0.57 13.19 8.96 0.64 14.18 9.21 0.68 13.75 10.40 0.60 13.47 11.19 0.55 45 9.25 8.14 0.48 10.47 8.44 0.53 11.70 8.75 0.58 13.22 9.13 0.65 14.14 9.36 0.69 14.10 10.66 0.62 14.07 11.52 0.58 50 9.56 8.41 0.51 10.70 8.68 0.55 11.83 8.95 0.60 13.25 9.29 0.66 14.11 9.50 0.69 14.44 10.91 0.64 14.67 11.86 0.61 55 9.87 8.68 0.53 10.92 8.92 0.57 11.97 9.16 0.61 13.29 9.46 0.67 14.07 9.64 0.70 14.79 11.17 0.67 15.27 12.19 0.64 60 10.18 8.96 0.56 11.14 9.16 0.60 12.11 9.37 0.63 13.32 9.62 0.67 14.04 9.78 0.70 15.14 11.42 0.69 15.87 12.52 0.68 65 10.09 8.87 0.59 11.00 9.12 0.62 11.92 9.37 0.66 13.06 9.69 0.70 13.75 9.87 0.72 14.84 11.43 0.72 15.57 12.47 0.71 70 9.99 8.79 0.62 10.86 9.09 0.65 11.72 9.38 0.68 12.81 9.75 0.72 13.46 9.97 0.75 14.55 11.44 0.75 15.28 12.42 0.75 75 9.90 8.71 0.65 10.72 9.05 0.68 11.53 9.39 0.71 12.55 9.81 0.75 13.17 10.06 0.77 14.26 11.44 0.78 14.99 12.36 0.78 80 9.81 8.63 0.67 10.57 9.01 0.70 11.34 9.39 0.73 12.30 9.87 0.77 12.87 10.16 0.79 13.97 11.45 0.81 14.70 12.31 0.82 85 9.71 8.55 0.70 10.43 8.98 0.73 11.15 9.40 0.76 12.05 9.93 0.79 12.58 10.25 0.81 13.67 11.46 0.84 14.40 12.26 0.85 90 9.62 8.47 0.73 10.29 8.94 0.76 10.96 9.41 0.78 11.79 9.99 0.82 12.29 10.35 0.83 13.38 11.46 0.87 14.11 12.21 0.89 95 9.53 8.39 0.76 10.15 8.90 0.78 10.76 9.41 0.81 11.54 10.06 0.84 12.00 10.44 0.86 13.09 11.47 0.89 13.82 12.16 0.92 100 9.28 8.17 0.77 9.91 8.70 0.80 10.55 9.24 0.82 11.34 9.91 0.85 11.81 10.31 0.87 12.86 11.29 0.91 13.57 11.94 0.93 105 9.03 7.95 0.78 9.68 8.51 0.81 10.33 9.07 0.83 11.14 9.77 0.86 11.63 10.19 0.88 12.64 11.11 0.92 13.31 11.72 0.95 110 8.78 7.73 0.79 9.45 8.31 0.82 10.11 8.90 0.84 10.94 9.63 0.88 11.44 10.06 0.90 12.41 10.92 0.93 13.06 11.50 0.96 115 8.47 7.45 0.80 9.11 8.02 0.83 9.75 8.59 0.85 10.56 9.30 0.89 11.04 9.73 0.91 11.99 10.55 0.94 12.62 11.11 0.97 118 8.28 7.29 0.81 8.91 7.84 0.83 9.54 8.40 0.86 10.33 9.10 0.89 10.80 9.52 0.91 11.74 10.33 0.95 12.36 10.88 0.98 122 8.03 7.43 0.82 8.64 8.00 0.84 9.25 8.57 0.87 10.02 9.28 0.90 10.48 9.71 0.92 11.38 10.54 0.96 11.99 11.09 0.99 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] SHC : Sensible Heating Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. : Indicates reference data. When operating at this temperature, these values can be different by discontinuous operation. 3. Direct interpolation is permissible. Do not extrapolate. 4. Capacities are based on the following conditions : - Interconnecting Piping Length 24.6 ft (7.5 m) - Level Difference of Zero. - Indoor Air Temperature : 80 ℉ (26.7 ℃) DB / 67 ℉ (19.4 ℃) WB - Outdoor Air Temperature : 95 ℉ (35.0 ℃) DB / 75 ℉ (23.9 ℃) WB Wall Mounted-60Hz(R410A) _ 42 Inverter Single Indoor Air Temperature : ℉DB / ℉WB Outdoor Air Temp. Inverter Single 8. Capacity Tables 8.2 Rated Heating Capacity Inverter Single Model : M09YJ Outdoor Air Temperature °FDB °FWB -3 -4 0 -1 1 0 6 5 10 9 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 60 TC 5.51 6.00 6.07 6.35 6.62 6.83 6.88 6.97 7.65 9.17 10.52 10.86 11.36 11.48 11.74 11.99 12.22 12.39 64 PI 0.47 0.51 0.52 0.54 0.55 0.56 0.56 0.58 0.60 0.65 0.69 0.70 0.71 0.72 0.73 0.74 0.75 0.76 TC 5.34 5.82 5.89 6.15 6.42 6.63 6.67 6.76 7.42 8.89 10.20 10.53 11.02 11.13 11.38 11.63 11.85 12.01 68 PI 0.46 0.51 0.51 0.53 0.55 0.55 0.56 0.57 0.59 0.64 0.68 0.69 0.71 0.71 0.72 0.74 0.75 0.76 TC 5.29 5.76 5.83 6.09 6.36 6.56 6.60 6.69 7.34 8.80 10.10 10.42 10.91 11.02 11.27 11.51 11.73 11.89 Indoor Air Temperature : °FDB 70 72 PI TC PI TC 0.46 5.24 0.46 5.20 0.51 5.70 0.50 5.66 0.51 5.77 0.51 5.73 0.53 6.03 0.53 5.98 0.55 6.30 0.54 6.25 0.55 6.49 0.55 6.45 0.56 6.54 0.55 6.49 0.57 6.63 0.56 6.58 0.59 7.27 0.59 7.21 0.64 8.71 0.63 8.65 0.68 10.00 0.67 9.92 0.69 10.32 0.68 10.24 0.71 10.80 0.70 10.72 0.71 10.91 0.71 10.82 0.72 11.16 0.71 11.07 0.74 11.39 0.73 11.31 0.75 11.61 0.74 11.52 0.76 11.77 0.75 11.68 PI 0.46 0.50 0.51 0.53 0.54 0.55 0.55 0.56 0.59 0.63 0.67 0.68 0.70 0.71 0.71 0.73 0.74 0.75 TC 5.09 5.54 5.61 5.86 6.12 6.32 6.36 6.44 7.07 8.47 9.72 10.03 10.50 10.61 10.85 11.08 11.29 11.45 Indoor Air Temperature : °FDB 70 72 PI TC PI TC 0.66 6.45 0.65 6.40 0.73 7.02 0.72 6.97 0.73 7.11 0.73 7.05 0.76 7.43 0.75 7.37 0.78 7.75 0.77 7.69 0.79 8.00 0.78 7.94 0.80 8.05 0.79 7.99 0.81 8.16 0.81 8.10 0.84 8.95 0.84 8.88 0.91 10.73 0.90 10.65 0.97 12.31 0.96 12.22 0.99 12.71 0.98 12.61 1.01 13.30 1.00 13.20 1.02 13.43 1.01 13.33 1.03 13.74 1.02 13.63 1.05 14.03 1.04 13.92 1.07 14.30 1.06 14.19 1.08 14.50 1.07 14.39 PI 0.65 0.72 0.73 0.75 0.77 0.78 0.79 0.81 0.84 0.90 0.96 0.98 1.00 1.01 1.02 1.04 1.06 1.07 TC 6.27 6.83 6.91 7.22 7.54 7.78 7.83 7.94 8.71 10.43 11.97 12.36 12.93 13.06 13.36 13.64 13.90 14.10 75 86 PI 0.45 0.50 0.50 0.52 0.54 0.54 0.55 0.56 0.58 0.63 0.67 0.68 0.69 0.70 0.71 0.72 0.73 0.74 TC 4.97 5.41 5.48 5.73 5.98 6.17 6.21 6.29 6.90 8.27 9.49 9.80 10.25 10.36 10.59 10.82 11.02 11.18 PI 0.65 0.71 0.72 0.74 0.77 0.77 0.78 0.80 0.83 0.89 0.95 0.97 0.99 1.00 1.01 1.03 1.04 1.06 TC 6.12 6.66 6.75 7.05 7.36 7.59 7.64 7.75 8.50 10.19 11.69 12.06 12.63 12.75 13.04 13.32 13.57 13.76 PI 0.45 0.50 0.50 0.52 0.54 0.54 0.55 0.56 0.58 0.63 0.67 0.68 0.69 0.70 0.71 0.72 0.73 0.74 Model : M12YJ Outdoor Air Temperature °FDB °FWB -3 -4 0 -1 1 0 6 5 10 9 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 60 TC 6.78 7.39 7.48 7.82 8.16 8.42 8.47 8.59 9.42 11.29 12.96 13.37 14.00 14.14 14.46 14.76 15.04 15.25 64 PI 0.67 0.73 0.74 0.77 0.79 0.80 0.81 0.82 0.85 0.92 0.98 1.00 1.02 1.03 1.04 1.06 1.08 1.09 TC 6.58 7.16 7.25 7.58 7.91 8.16 8.22 8.33 9.13 10.95 12.56 12.97 13.57 13.71 14.02 14.32 14.59 14.79 68 PI 0.66 0.73 0.73 0.76 0.78 0.79 0.80 0.81 0.84 0.91 0.97 0.99 1.01 1.02 1.03 1.05 1.07 1.08 TC 6.51 7.09 7.18 7.50 7.83 8.08 8.13 8.24 9.04 10.84 12.43 12.83 13.43 13.57 13.88 14.17 14.44 14.64 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) 43 _ Wall Mounted-60Hz(R410A) 75 86 PI 0.65 0.71 0.72 0.74 0.77 0.77 0.78 0.80 0.83 0.89 0.95 0.97 0.99 1.00 1.01 1.03 1.04 1.06 Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissible. Do not extrapolate 3. Capacities are based on the following conditions: - Interconnecting Piping Length 24.6 ft. (7.5 m) - Level Difference of Zero. - Indoor Air Temperature :70 ℉ (21.1 ℃) DB / 60 ℉ (15.6 ℃) WB - Outdoor Air Temperature : 47 ℉ (8.3 ℃) DB / 43 ℉ (6.1 ℃) WB Inverter Single 8. Capacity Tables Model : M18YJ 60 TC 10.30 11.22 11.36 11.87 12.39 12.78 12.87 13.04 14.31 17.15 19.68 20.31 21.26 21.47 21.96 22.42 22.85 23.17 64 PI 1.12 1.23 1.24 1.29 1.33 1.34 1.35 1.38 1.43 1.55 1.65 1.68 1.71 1.73 1.75 1.78 1.81 1.83 TC 9.99 10.88 11.02 11.51 12.02 12.39 12.48 12.65 13.87 16.63 19.08 19.69 20.61 20.82 21.29 21.74 22.16 22.47 68 PI 1.11 1.22 1.23 1.27 1.31 1.33 1.34 1.37 1.42 1.53 1.63 1.66 1.70 1.71 1.73 1.76 1.79 1.82 TC 9.89 10.77 10.90 11.39 11.89 12.27 12.35 12.52 13.73 16.46 18.89 19.49 20.40 20.61 21.08 21.52 21.93 22.24 Indoor Air Temperature : °FDB 70 72 PI TC PI TC 1.11 9.79 1.10 9.72 1.22 10.66 1.21 10.58 1.23 10.80 1.22 10.71 1.27 11.28 1.26 11.19 1.31 11.78 1.30 11.69 1.33 12.15 1.31 12.05 1.34 12.23 1.33 12.14 1.37 12.40 1.36 12.30 1.42 13.60 1.41 13.49 1.53 16.30 1.52 16.17 1.63 18.70 1.62 18.56 1.66 19.30 1.64 19.15 1.70 20.20 1.68 20.05 1.71 20.40 1.70 20.25 1.73 20.87 1.71 20.71 1.76 21.31 1.75 21.15 1.79 21.72 1.77 21.55 1.82 22.02 1.80 21.85 PI 1.10 1.21 1.22 1.26 1.30 1.31 1.33 1.36 1.41 1.52 1.62 1.64 1.68 1.70 1.71 1.75 1.77 1.80 TC 9.52 10.37 10.50 10.97 11.45 11.81 11.89 12.05 13.22 15.85 18.18 18.77 19.64 19.84 20.29 20.72 21.12 21.41 Indoor Air Temperature : °FDB 70 72 PI TC PI TC 1.57 13.09 1.56 12.99 1.73 14.25 1.71 14.14 1.74 14.43 1.73 14.32 1.80 15.08 1.79 14.96 1.86 15.74 1.84 15.62 1.88 16.24 1.86 16.11 1.90 16.35 1.88 16.22 1.94 16.57 1.92 16.44 2.01 18.17 1.99 18.03 2.17 21.78 2.15 21.62 2.31 24.99 2.29 24.80 2.35 25.80 2.33 25.60 2.40 27.00 2.38 26.79 2.43 27.27 2.40 27.06 2.45 27.89 2.43 27.68 2.50 28.49 2.48 28.27 2.54 29.03 2.51 28.80 2.57 29.43 2.55 29.21 PI 1.56 1.71 1.73 1.79 1.84 1.86 1.88 1.92 1.99 2.15 2.29 2.33 2.38 2.40 2.43 2.48 2.51 2.55 TC 12.73 13.86 14.03 14.66 15.31 15.79 15.90 16.11 17.67 21.18 24.30 25.09 26.26 26.52 27.12 27.70 28.22 28.62 75 86 PI 1.09 1.19 1.21 1.25 1.29 1.30 1.32 1.34 1.39 1.50 1.60 1.63 1.66 1.68 1.70 1.73 1.75 1.78 TC 9.30 10.12 10.25 10.71 11.18 11.53 11.61 11.77 12.91 15.47 17.75 18.32 19.18 19.37 19.81 20.23 20.61 20.90 PI 1.54 1.69 1.71 1.77 1.82 1.84 1.86 1.90 1.97 2.13 2.27 2.30 2.36 2.38 2.40 2.45 2.49 2.52 TC 12.43 13.53 13.70 14.31 14.94 15.41 15.52 15.73 17.25 20.68 23.73 24.49 25.63 25.89 26.48 27.04 27.55 27.94 PI 1.09 1.19 1.21 1.25 1.29 1.30 1.32 1.34 1.39 1.50 1.60 1.63 1.66 1.68 1.70 1.73 1.75 1.78 Model : M24YJ Outdoor Air Temperature °FDB °FWB -3 -4 0 -1 1 0 6 5 10 9 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 60 TC 13.77 14.99 15.18 15.87 16.56 17.09 17.20 17.43 19.12 22.92 26.30 27.14 28.41 28.70 29.35 29.97 30.54 30.97 64 PI 1.59 1.74 1.76 1.82 1.88 1.90 1.92 1.96 2.03 2.19 2.34 2.37 2.43 2.45 2.48 2.52 2.56 2.60 TC 13.36 14.54 14.72 15.38 16.06 16.57 16.68 16.91 18.54 22.23 25.50 26.32 27.55 27.82 28.46 29.06 29.62 30.03 68 PI 1.57 1.73 1.74 1.80 1.86 1.88 1.90 1.94 2.01 2.17 2.31 2.35 2.40 2.43 2.45 2.50 2.54 2.57 TC 13.22 14.39 14.57 15.23 15.90 16.40 16.51 16.73 18.35 22.00 25.24 26.05 27.27 27.54 28.17 28.77 29.32 29.72 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) 75 86 PI 1.54 1.69 1.71 1.77 1.82 1.84 1.86 1.90 1.97 2.13 2.27 2.30 2.36 2.38 2.40 2.45 2.49 2.52 Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissible. Do not extrapolate 3. Capacities are based on the following conditions: - Interconnecting Piping Length 24.6 ft. (7.5 m) - Level Difference of Zero. - Indoor Air Temperature :70 ℉ (21.1 ℃) DB / 60 ℉ (15.6 ℃) WB - Outdoor Air Temperature : 47 ℉ (8.3 ℃) DB / 43 ℉ (6.1 ℃) WB Wall Mounted-60Hz(R410A) _ 44 Inverter Single Outdoor Air Temperature °FDB °FWB -3 -4 0 -1 1 0 6 5 10 9 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 Inverter Single 8. Capacity Tables Inverter Single Model : M30YJ Outdoor Air Temperature °FDB °FWB -3 -4 0 -1 1 0 6 5 10 9 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 60 TC 16.32 17.77 18.00 18.80 19.63 20.25 20.39 20.66 22.66 27.17 31.17 32.17 33.67 34.01 34.78 35.52 36.20 36.70 64 PI 2.07 2.27 2.29 2.37 2.45 2.47 2.50 2.55 2.65 2.86 3.04 3.09 3.16 3.19 3.23 3.29 3.34 3.38 TC 15.83 17.23 17.45 18.23 19.03 19.63 19.77 20.04 21.98 26.34 30.22 31.20 32.65 32.98 33.73 34.45 35.10 35.59 68 PI 2.05 2.25 2.27 2.35 2.43 2.45 2.48 2.53 2.62 2.83 3.01 3.06 3.13 3.16 3.19 3.26 3.30 3.35 TC 15.67 17.06 17.27 18.05 18.84 19.44 19.57 19.83 21.75 26.08 29.92 30.88 32.32 32.64 33.39 34.10 34.74 35.23 Indoor Air Temperature : °FDB 70 72 PI TC PI TC 2.05 15.51 2.03 15.39 2.25 16.89 2.23 16.76 2.27 17.10 2.25 16.97 2.35 17.87 2.33 17.73 2.43 18.65 2.40 18.51 2.45 19.24 2.43 19.10 2.48 19.37 2.45 19.23 2.53 19.64 2.50 19.49 2.62 21.54 2.59 21.37 2.83 25.82 2.80 25.62 3.01 29.62 2.98 29.40 3.06 30.57 3.03 30.34 3.13 32.00 3.10 31.76 3.16 32.32 3.13 32.07 3.19 33.06 3.16 32.80 3.26 33.76 3.22 33.50 3.30 34.40 3.27 34.14 3.35 34.88 3.32 34.61 PI 2.03 2.23 2.25 2.33 2.40 2.43 2.45 2.50 2.59 2.80 2.98 3.03 3.10 3.13 3.16 3.22 3.27 3.32 TC 15.09 16.42 16.63 17.38 18.14 18.71 18.84 19.09 20.94 25.11 28.81 29.73 31.12 31.43 32.14 32.83 33.45 33.92 Indoor Air Temperature : °FDB 70 72 PI TC PI TC 2.53 17.06 2.51 16.93 2.78 18.58 2.76 18.43 2.81 18.81 2.78 18.67 2.91 19.66 2.88 19.51 3.00 20.52 2.97 20.36 3.04 21.17 3.01 21.01 3.07 21.31 3.04 21.15 3.13 21.60 3.10 21.43 3.24 23.69 3.21 23.51 3.50 28.40 3.47 28.18 3.73 32.58 3.70 32.34 3.79 33.63 3.75 33.37 3.88 35.20 3.84 34.93 3.92 35.55 3.88 35.28 3.96 36.36 3.92 36.08 4.03 37.14 3.99 36.85 4.09 37.84 4.05 37.55 4.15 38.37 4.11 38.07 PI 2.51 2.76 2.78 2.88 2.97 3.01 3.04 3.10 3.21 3.47 3.70 3.75 3.84 3.88 3.92 3.99 4.05 4.11 TC 16.59 18.06 18.29 19.11 19.95 20.58 20.72 21.00 23.04 27.62 31.69 32.70 34.23 34.57 35.36 36.11 36.80 37.31 75 86 PI 2.01 2.20 2.23 2.30 2.38 2.40 2.43 2.48 2.57 2.77 2.95 3.00 3.07 3.10 3.13 3.19 3.24 3.28 TC 14.73 16.03 16.24 16.96 17.71 18.27 18.39 18.64 20.45 24.51 28.12 29.02 30.38 30.68 31.38 32.05 32.66 33.11 PI 2.48 2.73 2.76 2.85 2.94 2.98 3.01 3.07 3.18 3.43 3.66 3.72 3.80 3.84 3.88 3.95 4.01 4.07 TC 16.20 17.63 17.86 18.66 19.48 20.10 20.23 20.51 22.49 26.96 30.93 31.93 33.42 33.75 34.52 35.25 35.92 36.42 PI 2.01 2.20 2.23 2.30 2.38 2.40 2.43 2.48 2.57 2.77 2.95 3.00 3.07 3.10 3.13 3.19 3.24 3.28 Model : M36YJ Outdoor Air Temperature °FDB °FWB -3 -4 0 -1 1 0 6 5 10 9 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 60 TC 17.96 19.55 19.80 20.68 21.59 22.27 22.43 22.73 24.93 29.88 34.29 35.39 37.04 37.41 38.26 39.08 39.82 40.37 64 PI 2.56 2.81 2.84 2.94 3.03 3.07 3.10 3.16 3.28 3.54 3.77 3.83 3.92 3.96 4.00 4.07 4.13 4.19 TC 17.41 18.95 19.19 20.06 20.94 21.60 21.75 22.04 24.17 28.98 33.25 34.31 35.92 36.28 37.10 37.89 38.61 39.15 68 PI 2.53 2.78 2.81 2.91 3.00 3.04 3.07 3.13 3.24 3.50 3.73 3.79 3.88 3.92 3.96 4.03 4.09 4.15 TC 17.23 18.76 19.00 19.85 20.73 21.38 21.53 21.82 23.93 28.68 32.91 33.97 35.55 35.91 36.73 37.51 38.22 38.75 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) 45 _ Wall Mounted-60Hz(R410A) 75 86 PI 2.48 2.73 2.76 2.85 2.94 2.98 3.01 3.07 3.18 3.43 3.66 3.72 3.80 3.84 3.88 3.95 4.01 4.07 Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissible. Do not extrapolate 3. Capacities are based on the following conditions: - Interconnecting Piping Length 24.6 ft. (7.5 m) - Level Difference of Zero. - Indoor Air Temperature :70 ℉ (21.1 ℃) DB / 60 ℉ (15.6 ℃) WB - Outdoor Air Temperature : 47 ℉ (8.3 ℃) DB / 43 ℉ (6.1 ℃) WB Inverter Single 8. Capacity Tables Model : HM12YJ 60 TC 8.61 8.66 8.78 9.63 11.55 13.25 13.67 14.31 14.45 14.78 15.10 15.38 15.60 64 PI 0.77 0.77 0.79 0.82 0.88 0.94 0.96 0.98 0.99 1.00 1.02 1.03 1.05 TC 8.34 8.40 8.52 9.34 11.20 12.85 13.26 13.88 14.02 14.33 14.64 14.92 15.13 68 PI 0.76 0.77 0.78 0.81 0.88 0.93 0.95 0.97 0.98 0.99 1.01 1.02 1.04 TC 8.26 8.32 8.43 9.25 11.08 12.72 13.12 13.74 13.87 14.19 14.49 14.77 14.97 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) Indoor Air Temperature : °FDB 70 72 PI TC PI TC 0.76 8.18 0.75 8.12 0.77 8.23 0.76 8.17 0.78 8.35 0.77 8.28 0.81 9.15 0.80 9.08 0.88 10.97 0.87 10.89 0.93 12.59 0.92 12.49 0.95 12.99 0.94 12.89 0.97 13.60 0.96 13.50 0.98 13.74 0.97 13.63 0.99 14.05 0.98 13.94 1.01 14.35 1.00 14.24 1.02 14.62 1.01 14.51 1.04 14.82 1.03 14.71 75 PI 0.75 0.76 0.77 0.80 0.87 0.92 0.94 0.96 0.97 0.98 1.00 1.01 1.03 TC 7.95 8.01 8.12 8.90 10.67 12.24 12.64 13.23 13.36 13.66 13.95 14.22 14.42 86 PI 0.74 0.75 0.77 0.80 0.86 0.92 0.93 0.95 0.96 0.97 0.99 1.00 1.02 TC 7.76 7.82 7.92 8.69 10.42 11.95 12.34 12.91 13.04 13.34 13.62 13.88 14.07 PI 0.74 0.75 0.77 0.80 0.86 0.92 0.93 0.95 0.96 0.97 0.99 1.00 1.02 Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissible. Do not extrapolate 3. Capacities are based on the following conditions: - Interconnecting Piping Length 24.6 ft. (7.5 m) - Level Difference of Zero. - Indoor Air Temperature :70 ℉ (21.1 ℃) DB / 60 ℉ (15.6 ℃) WB - Outdoor Air Temperature : 47 ℉ (8.3 ℃) DB / 43 ℉ (6.1 ℃) WB Wall Mounted-60Hz(R410A) _ 46 Inverter Single Outdoor Air Temperature °FDB °FWB 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 Inverter Single 8. Capacity Tables 8.3 Maximum Heating Capacity Inverter Single Model : M09YJ Outdoor Air Temperature °FDB °FWB -3 -4 0 -1 1 0 6 5 10 9 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 60 TC 8.43 8.90 9.10 10.10 10.63 11.12 11.25 11.39 12.48 14.23 16.20 16.64 17.53 17.98 18.21 18.35 18.42 18.37 64 PI 0.92 0.93 0.94 0.97 0.98 0.99 0.99 0.99 1.14 1.35 1.54 1.60 1.75 1.78 1.74 1.70 1.63 1.49 TC 8.38 8.84 9.03 10.00 10.52 10.99 11.12 11.25 12.34 14.07 16.02 16.45 17.32 17.76 18.19 18.08 18.10 18.00 68 PI 0.93 0.94 0.95 0.98 0.99 1.00 1.00 1.00 1.14 1.36 1.57 1.63 1.80 1.83 1.81 1.73 1.63 1.53 TC 8.34 8.78 8.96 9.92 10.42 10.89 11.01 11.14 12.22 13.93 15.86 16.29 17.15 17.58 18.18 17.86 17.84 17.70 Indoor Air Temperature : °FDB 70 72 PI TC PI TC 0.93 8.31 0.93 8.26 0.95 8.75 0.95 8.68 0.96 8.93 0.96 8.86 0.99 9.57 1.00 9.77 1.00 10.37 1.01 10.23 1.01 10.83 1.02 10.65 1.02 10.95 1.02 10.76 1.01 11.08 1.02 10.87 1.14 12.15 1.14 11.85 1.36 13.86 1.36 13.44 1.60 15.78 1.61 15.25 1.66 16.21 1.67 15.64 1.86 17.06 1.89 16.43 1.89 17.48 1.91 16.79 1.87 18.17 1.91 17.42 1.76 17.74 1.77 17.02 1.62 17.69 1.62 16.98 1.57 17.53 1.59 16.81 PI 0.94 0.96 0.97 0.99 1.00 1.01 1.01 1.00 1.12 1.32 1.55 1.60 1.80 1.81 1.80 1.68 1.54 1.50 TC 8.13 8.54 8.70 9.55 9.94 10.25 10.33 10.39 11.19 12.49 14.06 14.37 15.02 15.24 15.74 15.41 15.39 15.18 Indoor Air Temperature : °FDB 70 72 PI TC PI TC 1.31 10.14 1.31 10.06 1.34 10.66 1.34 10.58 1.35 10.88 1.36 10.79 1.40 11.67 1.41 11.90 1.42 12.63 1.43 12.47 1.43 13.19 1.44 12.98 1.43 13.34 1.45 13.11 1.43 13.50 1.44 13.24 1.51 15.05 1.51 14.68 1.64 17.53 1.64 17.00 1.77 20.32 1.79 19.64 1.81 20.94 1.82 20.21 1.92 22.18 1.95 21.36 1.95 22.72 1.97 21.82 1.93 23.62 1.97 22.65 1.81 23.06 1.83 22.13 1.68 23.00 1.67 22.08 1.62 22.78 1.64 21.85 PI 1.33 1.36 1.37 1.40 1.42 1.42 1.42 1.41 1.48 1.59 1.72 1.74 1.86 1.87 1.86 1.74 1.59 1.55 TC 9.91 10.40 10.60 11.63 12.11 12.48 12.58 12.66 13.86 15.80 18.11 18.56 19.52 19.80 20.46 20.03 20.01 19.74 75 86 PI 0.96 0.98 0.98 0.98 0.99 0.99 0.98 0.97 1.08 1.26 1.45 1.49 1.66 1.65 1.65 1.55 1.42 1.38 TC 7.74 8.10 8.21 8.52 8.68 9.03 9.04 8.96 9.19 9.65 10.50 10.55 10.77 10.58 10.69 10.58 10.62 10.32 PI 1.36 1.39 1.39 1.39 1.40 1.40 1.39 1.37 1.43 1.52 1.61 1.63 1.72 1.71 1.70 1.60 1.47 1.42 TC 9.43 9.87 10.01 10.38 10.57 11.01 11.01 10.92 11.39 12.21 13.52 13.63 14.00 13.76 13.89 13.75 13.81 13.41 PI 1.02 1.05 1.02 0.94 0.94 0.92 0.90 0.86 0.94 1.05 1.10 1.10 1.17 1.08 1.09 1.06 0.98 0.91 Model : M12YJ Outdoor Air Temperature °FDB °FWB -3 -4 0 -1 1 0 6 5 10 9 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 60 TC 10.27 10.85 11.09 12.31 12.96 13.55 13.71 13.87 15.46 18.00 20.86 21.50 22.78 23.37 23.67 23.86 23.94 23.88 64 PI 1.31 1.32 1.33 1.37 1.38 1.40 1.39 1.40 1.50 1.63 1.71 1.74 1.80 1.83 1.80 1.76 1.68 1.53 TC 10.21 10.77 11.00 12.19 12.81 13.39 13.55 13.71 15.28 17.80 20.62 21.25 22.52 23.08 23.65 23.51 23.52 23.40 68 PI 1.31 1.33 1.34 1.38 1.40 1.41 1.41 1.42 1.51 1.63 1.74 1.77 1.86 1.89 1.87 1.79 1.68 1.58 TC 10.16 10.70 10.92 12.08 12.69 13.27 13.41 13.57 15.13 17.62 20.43 21.05 22.30 22.85 23.63 23.22 23.19 23.00 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) 47 _ Wall Mounted-60Hz(R410A) 75 86 PI 1.44 1.48 1.45 1.33 1.33 1.29 1.27 1.21 1.24 1.26 1.22 1.20 1.20 1.12 1.12 1.10 1.01 0.94 Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissible. Do not extrapolate 3. Capacities are based on the following conditions: - Interconnecting Piping Length 24.6 ft. (7.5 m) - Level Difference of Zero. - Indoor Air Temperature :70 ℉ (21.1 ℃) DB / 60 ℉ (15.6 ℃) WB - Outdoor Air Temperature : 47 ℉ (8.3 ℃) DB / 43 ℉ (6.1 ℃) WB Inverter Single 8. Capacity Tables Model : M18YJ 60 TC 15.60 16.48 16.84 18.14 19.18 20.39 20.57 21.07 22.33 23.60 24.80 25.06 25.41 26.07 26.40 26.61 26.70 26.64 64 PI 2.19 2.21 2.23 2.30 2.31 2.33 2.35 2.36 2.37 2.30 2.14 2.05 1.98 2.01 1.97 1.93 1.84 1.68 TC 15.51 16.36 16.71 17.97 18.98 20.17 20.35 20.84 22.08 23.35 24.54 24.79 25.13 25.77 26.38 26.25 26.27 26.14 68 PI 2.19 2.23 2.25 2.33 2.34 2.36 2.38 2.38 2.38 2.30 2.18 2.09 2.04 2.08 2.05 1.96 1.84 1.73 TC 15.43 16.24 16.58 17.80 18.79 19.95 20.12 20.61 21.84 23.09 24.27 24.52 24.86 25.47 26.36 25.88 25.84 25.64 Indoor Air Temperature : °FDB 70 72 PI TC PI TC 2.20 15.39 2.20 15.25 2.24 16.19 2.25 16.03 2.27 16.53 2.28 16.35 2.36 17.73 2.37 17.48 2.37 18.70 2.39 18.38 2.39 19.85 2.40 19.41 2.41 20.02 2.43 19.56 2.41 20.51 2.42 19.98 2.39 21.73 2.39 21.01 2.31 22.98 2.31 22.03 2.22 24.15 2.24 23.06 2.13 24.40 2.15 23.24 2.11 24.74 2.14 23.50 2.14 25.34 2.17 23.98 2.12 26.35 2.16 24.87 1.99 25.72 2.01 24.31 1.84 25.65 1.84 24.26 1.78 25.41 1.80 23.99 PI 2.23 2.28 2.30 2.35 2.37 2.37 2.38 2.36 2.33 2.24 2.15 2.05 2.03 2.04 2.03 1.90 1.74 1.69 TC 15.05 15.81 16.11 17.15 17.94 18.80 18.94 19.25 20.03 20.74 21.56 21.67 21.81 22.13 22.86 22.38 22.36 22.06 Indoor Air Temperature : °FDB 70 72 PI TC PI TC 3.12 20.58 3.12 20.43 3.18 21.64 3.19 21.48 3.21 22.09 3.23 21.91 3.33 23.69 3.36 24.17 3.37 25.64 3.39 25.32 3.40 26.79 3.42 26.34 3.41 27.09 3.43 26.61 3.40 27.41 3.42 26.89 3.50 29.46 3.50 28.74 3.64 32.74 3.64 31.75 3.77 36.44 3.80 35.22 3.80 37.26 3.84 35.96 3.92 38.90 3.98 37.46 3.97 39.84 4.03 38.27 3.95 41.43 4.02 39.73 3.70 40.44 3.73 38.81 3.42 40.33 3.42 38.72 3.30 39.96 3.35 38.32 PI 3.16 3.23 3.26 3.33 3.36 3.38 3.38 3.35 3.42 3.53 3.65 3.68 3.79 3.81 3.80 3.54 3.25 3.17 TC 20.11 21.12 21.52 23.62 24.58 25.34 25.55 25.71 27.13 29.52 32.47 33.03 34.24 34.74 35.89 35.14 35.10 34.62 75 86 PI 2.27 2.32 2.32 2.33 2.33 2.32 2.31 2.29 2.25 2.14 2.01 1.91 1.88 1.86 1.86 1.75 1.60 1.55 TC 14.33 15.00 15.22 15.94 16.32 16.56 16.65 16.59 16.44 16.01 16.07 15.89 15.62 15.34 15.49 15.34 15.40 14.96 PI 3.22 3.29 3.30 3.29 3.32 3.31 3.30 3.25 3.30 3.38 3.42 3.43 3.50 3.48 3.48 3.26 2.99 2.90 TC 19.16 20.04 20.32 21.08 21.46 22.34 22.36 22.17 22.29 22.81 24.24 24.26 24.56 24.13 24.37 24.12 24.21 23.53 PI 2.42 2.48 2.42 2.24 2.22 2.16 2.06 2.03 1.95 1.78 1.53 1.42 1.32 1.22 1.23 1.20 1.11 1.03 Model : M24YJ Outdoor Air Temperature °FDB °FWB -3 -4 0 -1 1 0 6 5 10 9 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 60 TC 20.85 22.03 22.51 24.99 26.30 27.52 27.83 28.17 30.27 33.63 37.42 38.26 39.96 41.00 41.52 41.85 41.99 41.89 64 PI 3.11 3.14 3.15 3.25 3.28 3.31 3.30 3.33 3.48 3.62 3.63 3.66 3.68 3.75 3.67 3.59 3.43 3.13 TC 20.73 21.86 22.33 24.74 26.01 27.20 27.50 27.83 29.92 33.24 36.98 37.82 39.49 40.49 41.48 41.23 41.26 41.04 68 PI 3.11 3.16 3.18 3.29 3.33 3.36 3.36 3.37 3.49 3.63 3.70 3.73 3.80 3.86 3.81 3.65 3.43 3.22 TC 20.63 21.72 22.17 24.53 25.77 26.93 27.24 27.56 29.62 32.92 36.63 37.46 39.11 40.07 41.45 40.72 40.67 40.35 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) 75 86 PI 3.43 3.52 3.44 3.16 3.15 3.07 3.02 2.87 2.86 2.80 2.59 2.53 2.46 2.28 2.29 2.24 2.06 1.92 Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissible. Do not extrapolate 3. Capacities are based on the following conditions: - Interconnecting Piping Length 24.6 ft. (7.5 m) - Level Difference of Zero. - Indoor Air Temperature :70 ℉ (21.1 ℃) DB / 60 ℉ (15.6 ℃) WB - Outdoor Air Temperature : 47 ℉ (8.3 ℃) DB / 43 ℉ (6.1 ℃) WB Wall Mounted-60Hz(R410A) _ 48 Inverter Single Outdoor Air Temperature °FDB °FWB -3 -4 0 -1 1 0 6 5 10 9 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 Inverter Single 8. Capacity Tables Inverter Single Model : M30YJ Outdoor Air Temperature °FDB °FWB -3 -4 0 -1 1 0 6 5 10 9 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 60 TC 24.71 26.11 26.68 29.62 31.18 32.62 32.98 33.39 34.56 36.43 38.53 39.01 39.96 41.00 41.52 41.85 41.99 41.89 64 PI 4.05 4.09 4.10 4.24 4.28 4.32 4.31 4.35 4.36 4.24 3.95 3.91 3.68 3.75 3.67 3.59 3.43 3.13 TC 24.57 25.90 26.46 29.32 30.83 32.24 32.60 32.99 34.15 36.00 38.09 38.56 39.49 40.49 41.48 41.23 41.26 41.04 68 PI 4.06 4.12 4.15 4.29 4.34 4.38 4.38 4.39 4.37 4.25 4.02 3.99 3.80 3.86 3.81 3.65 3.43 3.22 TC 24.45 25.74 26.28 29.08 30.55 31.93 32.28 32.67 33.82 35.66 37.73 38.19 39.11 40.07 41.45 40.72 40.67 40.35 Indoor Air Temperature : °FDB 70 72 PI TC PI TC 4.07 24.39 4.06 24.22 4.15 25.65 4.16 25.46 4.19 26.18 4.21 25.97 4.34 28.08 4.37 28.65 4.39 30.39 4.42 30.01 4.43 31.75 4.46 31.23 4.44 32.11 4.48 31.55 4.44 32.49 4.46 31.87 4.39 33.63 4.39 32.82 4.27 35.47 4.27 34.39 4.10 37.52 4.13 36.27 4.06 37.98 4.10 36.66 3.92 38.90 3.98 37.46 3.97 39.84 4.03 38.27 3.95 41.43 4.02 39.73 3.70 40.44 3.73 38.81 3.42 40.33 3.42 38.72 3.30 39.96 3.35 38.32 PI 4.12 4.21 4.24 4.33 4.38 4.41 4.41 4.37 4.29 4.15 3.97 3.92 3.79 3.81 3.80 3.54 3.25 3.17 TC 23.84 25.03 25.50 27.99 29.14 30.04 30.29 30.47 30.98 31.97 33.44 33.68 34.24 34.74 35.89 35.14 35.10 34.62 Indoor Air Temperature : °FDB 70 72 PI TC PI TC 5.03 26.82 5.03 26.64 5.13 28.21 5.15 28.01 5.18 28.80 5.21 28.57 5.37 30.89 5.42 31.51 5.44 33.43 5.47 33.01 5.49 34.93 5.52 34.35 5.50 35.32 5.54 34.70 5.49 35.74 5.52 35.06 5.29 36.30 5.30 35.42 4.91 37.21 4.92 36.08 4.44 38.22 4.48 36.94 4.32 38.45 4.37 37.11 3.92 38.90 3.98 37.46 3.97 39.84 4.03 38.27 3.95 41.43 4.02 39.73 3.70 40.44 3.73 38.81 3.42 40.33 3.42 38.72 3.30 39.96 3.35 38.32 PI 5.10 5.22 5.25 5.36 5.42 5.45 5.46 5.41 5.18 4.77 4.30 4.18 3.79 3.81 3.80 3.54 3.25 3.17 TC 26.22 27.54 28.05 30.79 32.05 33.05 33.32 33.52 33.43 33.54 34.06 34.09 34.24 34.74 35.89 35.14 35.10 34.62 75 86 PI 4.20 4.29 4.30 4.29 4.32 4.32 4.31 4.24 4.14 3.96 3.72 3.66 3.50 3.48 3.48 3.26 2.99 2.90 TC 22.70 23.76 24.08 24.99 25.44 26.49 26.51 26.28 25.45 24.71 24.97 24.73 24.56 24.13 24.37 24.12 24.21 23.53 PI 5.19 5.31 5.32 5.31 5.35 5.35 5.33 5.24 5.00 4.56 4.03 3.90 3.50 3.48 3.48 3.26 2.99 2.90 TC 24.97 26.13 26.49 27.49 27.98 29.14 29.16 28.91 27.47 25.92 25.43 25.03 24.56 24.13 24.37 24.12 24.21 23.53 PI 4.47 4.58 4.49 4.12 4.11 4.01 3.93 3.75 3.59 3.28 2.82 2.70 2.46 2.28 2.29 2.24 2.06 1.92 Model : M36YJ Outdoor Air Temperature °FDB °FWB -3 -4 0 -1 1 0 6 5 10 9 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 60 TC 27.18 28.72 29.35 32.59 34.30 35.88 36.28 36.72 37.30 38.22 39.25 39.48 39.96 41.00 41.52 41.85 41.99 41.89 64 PI 5.01 5.06 5.08 5.24 5.30 5.35 5.33 5.38 5.27 4.88 4.28 4.16 3.68 3.75 3.67 3.59 3.43 3.13 TC 27.03 28.50 29.11 32.26 33.92 35.46 35.86 36.29 36.86 37.77 38.80 39.03 39.49 40.49 41.48 41.23 41.26 41.04 68 PI 5.02 5.10 5.13 5.31 5.37 5.42 5.42 5.44 5.28 4.90 4.36 4.24 3.80 3.86 3.81 3.65 3.43 3.22 TC 26.90 28.32 28.91 31.98 33.60 35.12 35.51 35.94 36.50 37.41 38.43 38.65 39.11 40.07 41.45 40.72 40.67 40.35 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) 49 _ Wall Mounted-60Hz(R410A) 75 86 PI 5.53 5.67 5.55 5.10 5.09 4.96 4.87 4.64 4.33 3.78 3.05 2.87 2.46 2.28 2.29 2.24 2.06 1.92 Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissible. Do not extrapolate 3. Capacities are based on the following conditions: - Interconnecting Piping Length 24.6 ft. (7.5 m) - Level Difference of Zero. - Indoor Air Temperature :70 ℉ (21.1 ℃) DB / 60 ℉ (15.6 ℃) WB - Outdoor Air Temperature : 47 ℉ (8.3 ℃) DB / 43 ℉ (6.1 ℃) WB Inverter Single 8. Capacity Tables Model : HM12YJ 60 TC 13.73 13.85 14.19 15.03 15.89 16.70 16.87 17.11 17.55 17.77 17.92 17.98 17.93 64 PI 1.33 1.34 1.35 1.36 1.31 1.22 1.17 1.13 1.15 1.13 1.10 1.05 0.96 TC 13.58 13.70 14.03 14.87 15.72 16.52 16.69 16.92 17.35 17.76 17.67 17.69 17.60 68 PI 1.35 1.36 1.36 1.36 1.32 1.25 1.20 1.17 1.19 1.17 1.12 1.05 0.99 TC 13.43 13.55 13.88 14.70 15.55 16.34 16.51 16.74 17.15 17.75 17.42 17.40 17.26 Symbol DB : Dry Bulb Temperature [°F] WB : Wet Bulb Temperature [°F] TC : Total Capacity [kBtu/h] PI : Power Input [kW] (Comp.+ Indoor Fan Motor + Outdoor Fan Motor) Indoor Air Temperature : °FDB 70 72 PI TC PI TC 1.37 13.37 1.37 13.07 1.38 13.48 1.39 13.17 1.37 13.81 1.38 13.45 1.36 14.63 1.36 14.14 1.32 15.47 1.32 14.83 1.27 16.26 1.28 15.52 1.22 16.43 1.23 15.65 1.21 16.65 1.22 15.82 1.22 17.06 1.24 16.14 1.21 17.74 1.23 16.75 1.14 17.31 1.15 16.36 1.05 17.27 1.05 16.33 1.02 17.11 1.03 16.15 75 PI 1.35 1.36 1.35 1.33 1.28 1.23 1.17 1.16 1.16 1.16 1.08 0.99 0.97 TC 12.65 12.75 12.96 13.49 13.96 14.51 14.59 14.68 14.90 15.39 15.07 15.05 14.85 86 PI 1.33 1.32 1.31 1.28 1.22 1.15 1.09 1.07 1.07 1.06 1.00 0.92 0.89 TC 11.15 11.21 11.17 11.07 10.78 10.82 10.70 10.51 10.33 10.43 10.33 10.37 10.07 PI 1.23 1.18 1.16 1.12 1.01 0.87 0.81 0.76 0.70 0.70 0.69 0.63 0.59 Note 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissible. Do not extrapolate 3. Capacities are based on the following conditions: - Interconnecting Piping Length 24.6 ft. (7.5 m) - Level Difference of Zero. - Indoor Air Temperature :70 ℉ (21.1 ℃) DB / 60 ℉ (15.6 ℃) WB - Outdoor Air Temperature : 47 ℉ (8.3 ℃) DB / 43 ℉ (6.1 ℃) WB Wall Mounted-60Hz(R410A) _ 50 Inverter Single Outdoor Air Temperature °FDB °FWB 16 14 17 15 19 17 24 23 32 30 41 38 43 40 47 43 53 50 59 53 64 57 70 61 75 65 Inverter Single 9. Capacity Coefficient Factor 9.1 Capacity Change Rate (%) Inverter Single Model Main Piping Length Indoor Unit Outdoor Unit MW09C1J MR09C1J MW12C1J MR12C1J MW18C3J MR18C3J MW24C3J MR24C3J MW09Y3J MR09Y3J MW12Y3J MR12Y3J MW18Y3J MR18Y3J MW24Y3J MR24Y3J MW30Y3J MR30Y3J MW36Y3J MR36Y3J MWH12Y3J MRH12Y3J 51 _ Wall Mounted-60Hz(R410A) m ft. Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating 7.5 24.6 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 10 32.8 97.5 97.5 99.0 98.9 97.5 98.8 97.5 98.8 99.0 99.2 99.6 99.6 97.5 98.8 99.6 99.6 98.3 98.3 15 49.2 92.5 92.5 97.0 96.7 92.5 96.3 92.5 96.3 97.0 97.6 98.8 98.8 92.5 96.3 98.8 98.8 95.0 95.0 20 65.6 87.5 87.5 95.0 94.4 87.5 93.8 87.5 93.8 95.0 96.0 97.9 97.9 97.9 97.9 97.9 97.9 - 25 82.0 92.2 97.1 97.1 97.1 97.1 97.1 97.1 - 30 98.4 90.0 96.3 96.3 96.3 96.3 96.3 96.3 - 35 40 45 50 114.8 131.2 147.6 164.0 95.5 94.6 93.8 93.0 95.5 94.6 93.8 93.0 95.5 94.6 93.8 93.0 95.5 94.6 93.8 93.0 95.5 94.6 93.8 93.0 95.5 94.6 93.8 93.0 - Inverter Single 9. Capacity Coefficient Factor 9.2 Pipe Size, Length and Elevation Model Max. Max. Standard Additional No Charge Pipe Length Elevation Length Refrigerant Length Ⓐ [ft. (m)] Ⓑ [ft. (m)] [oz./ft. (g/m)] [ft. (m)] [ft. (m)] Indoor Unit Outdoor Unit MW09C1J MR09C1J Ø 3/8 Ø 9.52 Ø 1/4 Ø 6.35 24.6 (7.5) 65.6 (20) 32.8 (10) 0.22 (20) 41.0 (12.5) MW12C1J MR12C1J Ø 3/8 Ø 9.52 Ø 1/4 Ø 6.35 24.6 (7.5) 65.6 (20) 32.8 (10) 0.22 (20) 41.0 (12.5) MW18C3J MR18C3J Ø 1/2 Ø 12.7 Ø 1/4 Ø 6.35 24.6 (7.5) 65.6 (20) 32.8 (10) 0.22 (20) 24.6 (7.5) MW24C3J MR24C3J Ø 5/8 Ø 15.88 Ø 3/8 Ø 9.52 24.6 (7.5) 98.4 (30) 49.2 (15) 0.38 (35) 24.6 (7.5) MW09Y3J MR09Y3J Ø 3/8 Ø 9.52 Ø 1/4 Ø 6.35 24.6 (7.5) 65.6 (20) 32.8 (10) 0.22 (20) 41.0 (12.5) MW12Y3J MR12Y3J Ø 3/8 Ø 9.52 Ø 1/4 Ø 6.35 24.6 (7.5) 65.6 (20) 32.8 (10) 0.22 (20) 41.0 (12.5) MW18Y3J MR18Y3J Ø 1/2 Ø 12.7 Ø 1/4 Ø 6.35 24.6 (7.5) 65.6 (20) 32.8 (10) 0.22 (20) 24.6 (7.5) MW24Y3J MR24Y3J Ø 5/8 Ø 15.88 Ø 3/8 Ø 9.52 24.6 (7.5) 164 (50) 98.4 (30) 0.38 (35) 24.6 (7.5) MW30Y3J MR30Y3J Ø 5/8 Ø 15.88 Ø 3/8 Ø 9.52 24.6 (7.5) 164 (50) 98.4 (30) 0.38 (35) 24.6 (7.5) MW36Y3J MR36Y3J Ø 5/8 Ø 15.88 Ø 3/8 Ø 9.52 24.6 (7.5) 164 (50) 98.4 (30) 0.38 (35) 24.6 (7.5) MWH12Y3J MRH12Y3J Ø 3/8 Ø 9.52 Ø 1/4 Ø 6.35 24.6 (7.5) 49.2 (15) 23.0 (7) 0.22 (20) 24.6 (7.5) Indoor unit Outdoor unit A B A Outdoor unit Indoor unit B Wall Mounted-60Hz(R410A) _ 52 Inverter Single Pipe Size GAS LIQUID inch mm inch mm Inverter Single 9. Capacity Coefficient Factor 9.3 Additional Refrigerant Charge Inverter Single Model Indoor Unit Outdoor Unit Refrigerant Pipe Length m ft. 7.5 24.6 10 32.8 12.5 41.0 15 49.2 1.8 (50) 20 65.6 5.4 (150) 25 82.0 30 98.4 35 40 45 50 114.8 131.2 147.6 164.0 - - - - - - MW09C1J MR09C1J 0 0 0 MW12C1J MR12C1J 0 0 0 1.8 (50) 5.4 (150) - - - - - - MW18C3J MR18C3J 0 1.8 (50) 3.6 (100) 5.4 (150) 9.0 (250) - - - - - - MW24C3J MR24C3J 0 3.1 (87.5) 6.2 (175) - - - - MW09Y3J MR09Y3J 0 0 0 1.8 (50) 5.4 (150) - - - - - - MW12Y3J MR12Y3J 0 0 0 1.8 (50) 5.4 (150) - - - - - - MW18Y3J MR18Y3J 0 1.8 (50) 3.6 (100) 5.4 (150) 9.0 (250) - - - - - - MW24Y3J MR24Y3J 0 3.1 (87.5) 6.2 (175) 9.3 15.6 21.8 28.0 34.3 40.5 46.7 53.0 (262.5) (437.5) (612.5) (787.5) (962.5) (1137.5) (1312.5) (1487.5) MW30Y3J MR30Y3J 0 3.1 (87.5) 6.2 (175) 9.3 15.6 21.8 28.0 34.3 40.5 46.7 53.0 (262.5) (437.5) (612.5) (787.5) (962.5) (1137.5) (1312.5) (1487.5) MW36Y3J MR36Y3J 0 3.1 (87.5) 6.2 (175) 9.3 15.6 21.8 28.0 34.3 40.5 46.7 53.0 (262.5) (437.5) (612.5) (787.5) (962.5) (1137.5) (1312.5) (1487.5) MWH12Y3J MRH12Y3J 0 1.8 (50) 3.6 (100) Additional Charge [oz. (g)] 9.3 15.6 21.8 28.0 (262.5) (437.5) (612.5) (787.5) 5.4 (150) - - - - Note • Capacity is based on standard length and maximum allowance length is on the basis of reliability. • Equivalent pipe length = actual pipe length + number of bends x 0.3 • Calculation : X oz. (g) = [ (Refrigerant Pipe Length) - (No Charge Length) ] × (Additional Refrigerant) • There is no need to charge till no charge length based on reliability. 53 _ Wall Mounted-60Hz(R410A) - - - Inverter Single 10. Electric Characteristics Model Unit Outdoor Unit MW09C1J MR09C1J Type Hz Voltage 115 Voltage Range Min : 104 Max : 127 Compressor RLA MCA MOP MSC Cool Heat OFM IFM W FLA W FLA 14.5 20.0 - 10.6 - 43 0.4 20 0.5 14.5 20.0 - 10.6 - 43 0.4 20 0.5 MW12C1J MR12C1J MW18C3J MR18C3J 13.0 20.0 - 9.75 - 85 0.25 30 0.5 MW24C3J MR24C3J 19.0 30.0 - 14.6 - 124 0.25 30 0.5 MW09Y3J MR09Y3J 10.0 15.0 - 7.6 7.6 43 0.25 20 0.2 MW12Y3J MR12Y3J 10.0 15.0 - 7.6 7.6 43 0.25 20 0.2 MW18Y3J MR18Y3J Min : 187 13.0 Max : 253 20.0 - 9.75 9.75 85 0.25 30 0.5 MW24Y3J MR24Y3J 23.0 35.0 - 17.3 17.3 124 0.25 113.1 0.5 MW30Y3J MR30Y3J 23.0 35.0 - 17.3 17.3 124 0.25 113.1 0.5 MW36Y3J MR36Y3J 23.0 35.0 - 17.3 17.3 124 0.25 113.1 0.5 MWH12Y3J MRH12Y3J 10.0 15.0 - 7.6 7.6 85 0.14 0.2 Inverter 60 208 / 230 Note 1. Voltage range Voltage supplied to the unit terminals should be within the minimum and maximum range. 2. Maximum allowable voltage unbalance between phase is 2 %. 3. Select wire spec. based on the larger value of MCA. 4. RLA is measured during each individual compressor test condition. 5. OFM is measured as the outdoor unit test condition. 6. Recommended circuit breaker is ELCB (Earth Leakage Circuit Breaker) 20 MCA : Minimum Circuit Amperes (A) MOP : Maximum Rating Over Current Protective Device (A) MSC : Maximum Starting Current (A) RLA : Rated Load Amperes (A) OFM : Outdoor Fan Motor IFM : Indoor Fan Motor W : Fan Motor Rated Output (W) FLA : Full Load Amperes (A) Wall Mounted-60Hz(R410A) _ 54 Inverter Single Indoor Unit Power Inverter Single 11. Operation Range Inverter Single Model : M09CJ, M12CJ, M18CJ, M24CJ, M09YJ, M12YJ, M18YJ, M24YJ, M30YJ, M36YJ Cooling Heating 118 (48) Outdoor Unit Continuous operation [℉ (℃) DB] 65 (18.3) Outdoor Unit Continuous [℉ (℃) WB] operation -4 (-20) 14(-10) 53 (12) 75 (23) Indoor Unit [℉ (℃) WB] Note The figures are based on the following conditions : - Equivalent Piping Length : 24.6 ft. (7.5 m) - Level Difference : 0 ft. (0 m) 55 _ Wall Mounted-60Hz(R410A) 60 (16) 86 (30) Indoor Unit [℉ (℃) DB] Inverter Single 11. Operation Range Model : HM12YJ Inverter Single Cooling Heating 118 (48) Outdoor Unit Continuous operation [℉ (℃) DB] 65 (18.3) Outdoor Unit Continuous [℉ (℃) WB] operation 14(-10) 14(-10) 53 (12) 75 (23) Indoor Unit [℉ (℃) WB] 60 (16) 86 (30) Indoor Unit [℉ (℃) DB] Note The figures are based on the following conditions : - Equivalent Piping Length : 24.6 ft. (7.5 m) - Level Difference : 0 ft. (0 m) Wall Mounted-60Hz(R410A) _ 56 Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) Inverter Single Model : M09CJ, M09YJ Cooling Air Velocity [m/s (ft./s)] Temperature [℃ (℉)] ft. 6.6 1 3.3 m 2 ft. 6.6 1 3.3 0 0 18(64) 2(6.6) 1.5(4.9) 0.5(1.6) 1(3.3) 0.3(1) m 2 0 24(75) 26(79) 28(82) 0 m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 Side View Discharge Angle : 88˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 m ft. 5 16.4 4 13.1 3 9.8 2 6.6 1 3.3 0 0 1 3.3 2 6.6 3 9.8 3 9.8 4 13.1 4 13.1 5 16.4 4 13.1 3 9.8 0.3(1) 0.5(1.6) 1(3.3) 2(6.6) m ft. 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 2 6.6 1 3.3 0 0 1 3.3 2 6.6 5 16.4 1(3.3) 0.5(1.6) 0.3(1) 2(6.6) 2(6.6) 0.3(1) m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 88˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 4.6 m (15.1 ft./s) Discharge Angle : 88˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 57 _ Wall Mounted-60Hz(R410A) 1(3.3) 0.5(1.6) 2 6.6 ) 0 0 Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) Model : M09YJ Air Velocity [m/s (ft./s)] Temperature [℃ (℉)] m 2 m ft. 6.6 2(6.6) 1.5(4.9) 1 0.3(1) 0.5(1.6) 1(3.3) 24(75) 3.3 0 ft. 6.6 34(93) 2 30(86) 24(75) 26(79)28(82) 0 m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 1 3.3 0 0 Side View Discharge Angle : 38˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 m ft. 5 16.4 0.5(1.6) 4 13.1 3 9.8 2 0.3(1) 0.5(1.6) 1(3.3) 2(6.6) 6.6 1 3.3 0 0 1 3.3 2 6.6 0.3(1) 1(3.3) 2(6.6) 2(6.6) 1(3.3) 0.3(1) 3 9.8 0.5(1.6) 4 13.1 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 5 16.4 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 38˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 9.5 m (31.2 ft./s) Discharge Angle : 38˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 2 6.6 0 0 4 13.1 3 9.8 2 6.6 1 3.3 0 0 1 3.3 2 6.6 3 9.8 4 13.1 5 16.4 ) Wall Mounted-60Hz(R410A) _ 58 Inverter Single Heating Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) Inverter Single Model : M12CJ, M12YJ Cooling Air Velocity [m/s (ft./s)] Temperature [℃ (℉)] m 2 ft. 6.6 2(6.6) 1.5(4.9) 1 0.3(1) 0.5(1.6) 1(3.3) 3.3 0 m ft. 6.6 16(61) 2 22(72) 24(75) 26(79) 28(82) 0 m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 1 3.3 0 0 Side View Discharge Angle : 88˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 m ft. 5 16.4 4 13.1 3 9.8 2 6.6 1 3.3 0 0 1 3.3 2 6.6 3 9.8 3 9.8 4 13.1 4 13.1 5 16.4 4 13.1 3 9.8 0.3(1) 2 1(3.3) 6.6 0.3(1) 0.5(1.6) 2(6.6) 1(3.3) m ft. 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 1 3.3 0 0 1 3.3 2 6.6 5 16.4 0.5(1.6) 2(6.6) 2(6.6) 0.3(1) m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 88˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 4.6 m (15.1 ft./s) Discharge Angle : 88˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 59 _ Wall Mounted-60Hz(R410A) 1(3.3) 0.5(1.6) 2 6.6 ) 0 0 Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) M12Y3J (US-W123B4B0) Model : M12YJ Air Velocity [m/s (ft./s)] Temperature [℃ (℉)] 2(6.6) 1.5(4.9) 0.3(1) 0.5(1.6) 1(3.3) m 2 ft. 6.6 1 3.3 0 0 m ft. 6.6 38(100) 2 32(90) 1 30(86) 26(79) 28(82) 24(75) 3.3 0 m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 0 Side View Discharge Angle : 38˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 m ft. 5 16.4 0.5(1.6) 4 13.1 3 9.8 2 0.3(1) 0.5(1.6) 1 1(3.3) 6.6 0.3(1) 1(3.3) 3.3 4 13.1 3 9.8 2 6.6 1 3.3 0 0 1 3.3 2 6.6 3 9.8 4 13.1 5 16.4 2(6.6) 2(6.6) 0 0 2(6.6) 1 3.3 2 6.6 1(3.3) 0.3(1) 3 9.8 0.5(1.6) 4 13.1 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 5 16.4 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 38˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 9.7 m (31.8 ft./s) Discharge Angle : 38˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 2 6.6 0 0 ) Wall Mounted-60Hz(R410A) _ 60 Inverter Single Heating Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) Inverter Single Model : M18CJ, M18YJ Cooling Air Velocity [m/s (ft./s)] Temperature [℃ (℉)] 2(6.6) 1.5(4.9) m 2 ft. 6.6 1 3.3 0 0 m 28(82) 0.5(1.6) 1(3.3) 0.3(1) 26(79) ft. 6.6 16(61) 2 20(68) 22(72) 1 24(75) 3.3 0 m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 0 Side View Discharge Angle : 67˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 m ft. 5 16.4 4 13.1 4 13.1 3 9.8 2 6.6 1 3.3 0 0 1 3.3 2 6.6 3 9.8 4 13.1 5 16.4 0.3(1) 3 9.8 0.5(1.6) 1(3.3) 2(6.6) 2 6.6 1 3.3 0 0 0.5(1.6) 1(3.3) 2(6.6) 0.3(1) 0.3(1) 1 3.3 2 6.6 2(6.6) 0.5(1.6) 3 9.8 1(3.3) 4 13.1 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 5 16.4 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 67˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 10.6 m (34.8 ft./s) Discharge Angle : 67˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 61 _ Wall Mounted-60Hz(R410A) 2 6.6 ) 0 0 Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) Model : M18Y3J M18YJ (AS-W183C4B0) Air Velocity [m/s (ft./s)] 0.3(1) Temperature [℃ (℉)] 2(6.6) 0.5(1.6) 1(3.3) 1.5(4.9) m 2 ft. 6.6 1 3.3 0 0 m 24(75) 30(86) 28(82) 26(79) ft. 6.6 36(97) 2 m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 1 3.3 0 0 Side View Discharge Angle : 52˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 m ft. 5 16.4 0.3(1) 4 13.1 0.3(1) 0.5(1.6) 1(3.3) 3 9.8 2 6.6 4 13.1 3 9.8 2 6.6 1 3.3 0 0 1 3.3 2 6.6 3 9.8 4 13.1 5 16.4 0.5(1.6) 1(3.3) 2(6.6) 1 3.3 0 0 1 3.3 2 6.6 2(6.6) 2(6.6) 0.5(1.6) 3 9.8 1(3.3) 4 13.1 0.3(1) m ft. 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 5 16.4 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 52˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 14.9 m (48.9 ft./s) Discharge Angle : 52˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 2 6.6 0 0 ) Wall Mounted-60Hz(R410A) _ 62 Inverter Single Heating Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) Inverter Single Model : M24CJ Cooling Air Velocity [m/s (ft./s)] Temperature [℃ (℉)] 2(6.6) 0.3(1) 0.5(1.6) 1(3.3) 1.5(4.9) m 2 ft. 6.6 1 3.3 m 22(72) 26(79) 0 ft. 6.6 14(57) 2 20(68) 24(75) 0 m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 1 3.3 0 0 Side View Discharge Angle : 67˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 m ft. 5 16.4 4 13.1 0.3(1) 0.5(1.6) 3 9.8 0.5(1.6) 1(3.3) 2(6.6) 2 6.6 1 3.3 0 0 1 3.3 2 6.6 1(3.3) 0.3(1) 2(6.6) 0.3(1) 2(6.6) 0.5(1.6) 3 9.8 1(3.3) 4 13.1 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 5 16.4 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 67˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 10.6 m (34.8 ft./s) Discharge Angle : 67˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 63 _ Wall Mounted-60Hz(R410A) 2 6.6 ) 0 0 4 13.1 3 9.8 2 6.6 1 3.3 0 0 1 3.3 2 6.6 3 9.8 4 13.1 5 16.4 Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) Model : M24YJ Air Velocity [m/s (ft./s)] Temperature [℃ (℉)] m 2 ft. 6.6 1 3.3 2(6.6) 0.3(1) 0.5(1.6) 24(75) 1.5(4.9) 1(3.3) m ft. 6.6 1 3.3 0 0 18(64) 2 22(72) 26(79) 0 0 m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 Side View Discharge Angle : 65˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 0.3(1) 1(3.3) 4 13.1 3 9.8 3 9.8 2 6.6 2 6.6 1 3.3 1 3.3 0 0 0 0 1 3.3 4 13.1 0.5(1.6) m ft. 5 16.4 1(3.3) 2(6.6) 2(6.6) 0.5(1.6) 0.3(1) 3.3 2 6.6 2 6.6 3 9.8 3 9.8 4 13.1 5 16.4 4 13.1 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 2(6.6) 0.5(1.6) 1 5 16.4 1(3.3) m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 65˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 14.0 m (45.9 ft./s) Discharge Angle : 65˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 2 6.6 0 0 ) Wall Mounted-60Hz(R410A) _ 64 Inverter Single Cooling Inverter Single Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) Heating Air Velocity [m/s (ft./s)] Temperature [℃ (℉)] m 0.3(1) 7(23) 2 ft. 6.6 1 3.3 2(6.6) 1.5(4.9) 0.5(1.6) 1(3.3) 0 36(97) 2 m ft. 6.6 1 3.3 0 0 26(79) 30(86) 28(82) 0 m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 Side View Discharge Angle : 50˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 4 13.1 0.3(1) 0.5(1.6) 1(3.3) 3 9.8 1(3.3) 2(6.6) 2 6.6 1 3.3 0 0 m ft. 5 16.4 0.5(1.6) 2(6.6) 0.3(1) 4 13.1 3 9.8 2 6.6 1 3.3 0 0 1 3.3 2 6.6 3 9.8 4 13.1 5 16.4 0.3(1) 1 3.3 2 6.6 2(6.6) 0.5(1.6) 3 9.8 1(3.3) 4 13.1 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 5 16.4 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 50˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 18.7 m (61.4 ft./s) Discharge Angle : 50˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 65 _ Wall Mounted-60Hz(R410A) 2 6.6 ) 0 0 Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) Model : M30YJ Air Velocity [m/s (ft./s)] Temperature [℃ (℉)] 7(23) m 2 ft. 6.6 1 3.3 0 0 m 22(72) 2(6.6) 0.3(1) 0.5(1.6) 1.5(4.9) 1(3.3) 26(79) 14(57) 2 ft. 6.6 1 3.3 0 0 24(75) m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 Side View Discharge Angle : 65˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 0.3(1) 1(3.3) 4 13.1 3 9.8 3 9.8 2 6.6 2 6.6 1 3.3 1 3.3 0 0 0 0 1 3.3 1 3.3 2 6.6 2 6.6 3 9.8 3 9.8 4 13.1 5 16.4 4 13.1 0.5(1.6) 1(3.3) 2(6.6) 0.5(1.6) 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 5 16.4 2(6.6) 0.3(1) 2(6.6) 0.5(1.6) 4 13.1 m ft. m ft. 5 16.4 1(3.3) m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 65˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 13.7 m (44.9 ft./s) Discharge Angle : 65˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 2 6.6 0 0 ) Wall Mounted-60Hz(R410A) _ 66 Inverter Single Cooling Inverter Single Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) Heating Air Velocity [m/s (ft./s)] Temperature [℃ (℉)] 2(6.6) 0.3(1) 7(23) 1.5(4.9) 0.5(1.6) 1(3.3) m 2 ft. 6.6 1 3.3 0 m ft. 6.6 40(104) 2 34(93) 28(82) 0 1 3.3 0 0 32(90) 30(86) m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 Side View Discharge Angle : 50˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 0.3(1) 4 13.1 1(3.3) 3 9.8 0.5(1.6) 1(3.3) 2(6.6) 2 6.6 1 3.3 0 0 m ft. 5 16.4 0.5(1.6) 2(6.6) 0.3(1) 0.3(1) 1 3.3 2 6.6 2(6.6) 0.5(1.6) 3 9.8 1(3.3) 4 13.1 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 5 16.4 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 50˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 19.4 m (63.6 ft./s) Discharge Angle : 50˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 67 _ Wall Mounted-60Hz(R410A) 2 6.6 ) 0 0 4 13.1 3 9.8 2 6.6 1 3.3 0 0 1 3.3 2 6.6 3 9.8 4 13.1 5 16.4 Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) Model : M36YJ Air Velocity [m/s (ft./s)] Temperature [℃ (℉)] m 0.5(1.6) ft. 6.6 1 3.3 14(57) 2 m ft. 6.6 1 3.3 0 0 22(72) 2(6.6) 1.5(4.9) 0.3(1) 6.5(21.3) 2 26(79) 24(75) 1(3.3) 0 0 m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 Side View Discharge Angle : 65˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 m ft. 5 16.4 0.3(1) 1(3.3) 4 13.1 3 9.8 2 6.6 1 3.3 0 0 1 3.3 6.6 2 6.6 3 9.8 3 9.8 4 13.1 5 16.4 4 13.1 0.5(1.6) 3 9.8 2 6.6 1(3.3) 2(6.6) 1 3.3 0 0 1 3.3 0.5(1.6) 2(6.6) 0.3(1) 2(6.6) 0.5(1.6) 2 4 13.1 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 5 16.4 1(3.3) m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 65˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 13.6 m (44.6 ft./s) Discharge Angle : 65˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 2 6.6 0 0 ) Wall Mounted-60Hz(R410A) _ 68 Inverter Single Cooling Inverter Single Inverter Single 12. Air Flow and Temperature Distributions (Reference Data) Heating Air Velocity [m/s (ft./s)] Temperature [℃ (℉)] 7(23) 2(6.6) 0.3(1) 0.5(1.6) m 2 ft. 6.6 1 3.3 m 28(82) 1.5(4.9) 1(3.3) 0 0 40(104) 2 ft. 6.6 1 3.3 0 0 34(93) 30(86) 32(90) m 10 8 6 4 2 0 m 10 8 6 4 2 0 ft. 32.8 26.2 19.7 13.1 6.6 0 ft. 32.8 26.2 19.7 13.1 6.6 0 Side View Discharge Angle : 50˚ (From the wall Vertical Louver : Center Fan Speed : Power ) Air Velocity [m/s (ft./s)] Air Velocity [m/s (ft./s)] m ft. 5 16.4 0.3(1) 4 13.1 0.5(1.6) m ft. 5 16.4 1(3.3) 3 9.8 4 13.1 3 9.8 2 6.6 1 3.3 0 0 1 3.3 2 6.6 3 9.8 4 13.1 5 16.4 0.5(1.6) 1(3.3) 2 6.6 1 3.3 2(6.6) 0.3(1) 2(6.6) 0 0 1 3.3 2 6.6 0.3(1) 2(6.6) 0.5(1.6) 3 9.8 1(3.3) 4 13.1 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 2 6.6 0 0 5 16.4 m ft. 10 32.8 8 26.2 6 19.7 4 13.1 Top View Top View Discharge Angle : 50˚ (From the wall ) Vertical Louver : Center Fan Speed : Power Air speed 0.3 m/s (1 ft./s) Range : 19.2 m (63.0 ft./s) Discharge Angle : 50˚ (From the wall Vertical Louver : Left & Right Fan Speed : Power 69 _ Wall Mounted-60Hz(R410A) 2 6.6 ) 0 0 Inverter Single 13. Sound Levels (Reference Data) 13.1 Indoor Unit Overall 3.28 (1) 2.62 (0.8) Microphone Model Sound Levels [dB(A)] H M L MW09C1J 39 33 24 MW12C1J 39 33 24 MW18C3J 45 40 35 MW24C3J 46 40 35 MW09Y3J 39 33 24 MW12Y3J 39 33 24 MW18Y3J 45 40 35 MW24Y3J 49 44 40 MW30Y3J 49 44 40 MW36Y3J 49 44 40 MWH12Y3J 39 34 26 Wall Mounted-60Hz(R410A) _ 70 Inverter Single Note - Sound measured at 3.28 ft. (1 m) away from the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Reference acoustic pressure 0dB=20μPa. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard. - Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. - Sound level is measured in an anechoic room and may be different according to the test condition or equipment. Unit : ft. (m) Inverter Single 13. Sound Levels (Reference Data) MW18C3J MW24C3J MW18Y3J 80 70 70 70 NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 Approximate Hearing Threshold 10 63 NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 Approximate Hearing Threshold NC-15 125 250 500 1000 2000 4000 NC-25 20 NC-20 10 8000 63 Octave Band Center Frequency (Hz) 70 NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold Octave Band Sound Pressure Level (0dB = 20μPa) 70 NC-15 500 1000 2000 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 125 250 500 1000 2000 4000 NC-25 20 Approximate Hearing Threshold NC-15 10 8000 63 NC-20 NC-15 125 4000 8000 Octave Band Center Frequency (Hz) 71 _ Wall Mounted-60Hz(R410A) 500 1000 2000 4000 8000 MWH12Y3J 80 NC-65 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold 10 250 Octave Band Center Frequency (Hz) 60 NC-20 250 NC-55 50 MW36Y3J 80 125 NC-60 NC-20 MW30Y3J 63 NC-65 60 Octave Band Center Frequency (Hz) 80 10 Octave Band Sound Pressure Level (0dB = 20μPa) 80 20 Octave Band Sound Pressure Level (0dB = 20μPa) MW24Y3J 80 Octave Band Sound Pressure Level (0dB = 20μPa) Octave Band Sound Pressure Level (0dB = 20μPa) MW09C1J MW12C1J MW09Y3J MW12Y3J 63 Octave Band Sound Pressure Level (0dB = 20μPa) Inverter Single Sound Pressure Level 70 NC-60 125 250 500 1000 2000 4000 Octave Band Center Frequency (Hz) 8000 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 20 NC-20 NC-15 NC-65 60 10 NC-25 Approximate Hearing Threshold 63 125 NC-20 250 500 NC-15 1000 2000 4000 8000 Octave Band Center Frequency (Hz) Inverter Single 13. Sound Levels (Reference Data) 13.2 Outdoor Unit Overall Center of Outdoor Unit 3.28 (1) Sound Levels [dB(A)] Model H MR09C1J 45 MR12C1J MR18C3J 45 Center of Outdoor Unit 53 MR24C3J 54 MR09Y3J 45 MR12Y3J 45 MR18Y3J 53 MR24Y3J 55 MR30Y3J 55 MR36Y3J 55 MRH12Y3J 51 Wall Mounted-60Hz(R410A) _ 72 Inverter Single Note - Sound measured at 3.28 ft. (1 m) away from the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Reference acoustic pressure 0dB=20μPa. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard. - Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. - Sound level is measured in an anechoic room and may be different according to the test condition or equipment. Unit : ft. (m) Inverter Single 13. Sound Levels (Reference Data) MR18C3J MR18Y3J 80 80 70 70 70 NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold 10 63 NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 Approximate Hearing Threshold NC-15 125 250 500 1000 2000 4000 NC-25 20 NC-20 10 8000 63 Octave Band Center Frequency (Hz) NC-15 125 70 NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold Octave Band Sound ressure Level (0dB = 20μPa) 70 63 500 1000 2000 4000 8000 2000 4000 8000 Octave Band Center Frequency (Hz) NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 73 _ Wall Mounted-60Hz(R410A) NC-25 20 Approximate Hearing Threshold 10 63 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-20 NC-15 125 250 500 1000 2000 4000 Octave Band Center Frequency (Hz) NC-25 20 Approximate Hearing Threshold 10 63 NC-20 NC-15 125 250 500 1000 2000 4000 Octave Band Center Frequency (Hz) NC-65 NC-15 250 1000 60 NC-20 125 500 MRH12Y3J 80 10 250 Octave Band Center Frequency (Hz) 80 NC-65 60 NC-20 MR24Y3J MR30Y3J MR36Y3J Octave Band Sound Pressure Level (0dB = 20μPa) MR24C3J 80 Octave Band Sound Pressure Level (0dB = 20μPa) Octave Band Sound Pressure Level (0dB = 20μPa) MR09C1J MR12C1J MR09Y3J MR12Y3J Octave Band Sound Pressure Level (0dB = 20μPa) Inverter Single Sound Pressure Level 8000 8000 Inverter Single 14. Remote Controller Wireless Remote Controller Control panel Display screen / 4 l Description Fan button : Fan only operation no cooling Sleep mode auto button*: Sets the sleep mode auto operation. _ Temperature adjustment buttons: Adjusts the room temperature when cooling. | - On/Off button: Turns the power on/off. g L Indoor fan speed button: Adjusts the fan speed. A C D B Operation mode selection button*: Selects the operation mode. Cooling operation (A) / Auto operation or auto changeover (C) / Dehumidifying operation (D) / Heating operation (B) f Cooling only model A C Surge button*: Warms up or cools down the indoor temperature within a short period of time. P/No Applied Model DE IJ Air flow direction button: Adjusts the air flow direction vertically or horizontally. G - Adjusts the brightness of the indoor unit display. MW09Y3J, MW12Y3J k S MW18Y3J, MW24Y3J, MW30Y3J, MW36Y3J, MWH12Y3J Temperature display button: Displays the room temperature. Also changes unit from °C to °F if pressed for 5 seconds. mn Timer button: Sets the current time and the start / end time. O P J G Navigation and functions button*: Sets the special functions. J: Auto clean G: Operates energy saving cooling p - Set/clear button: Sets or cancels functions. r - Reset button: Resets the air conditioner settings. AKB73456119 MW09C1J, MW12C1J AKB73975604 MW18C3J, MW24C3J AKB73456118 AKB73975603 * Some functions may not be supported, depending on the model. Wall Mounted-60Hz(R410A) _ 74 Inverter Single Display screen Control panel Inverter Single 15. Installation Inverter Single Important Safety Instructions READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product. ! WARNING It can result in serious injury or death when the directions are ignored. ! CAUTION It can result in minor injury or product damage when the directions are ignored. ! WARNING • Installation or repairs made by unqualified persons can result in hazards to you and others. • Air conditioner Shall be installed in accordance with national wiring regulations. • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similary qualified persons in order to avoid a hazard. • The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments. • Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death. Installation • Always perform grounding. - Otherwise, it may cause electrical shock. • Don’t use a power cord, a plug or a loose socket which is damaged. - Otherwise, it may cause a fire or electrical shock. • For installation of the product, always contact the service center or a professional installation agency. - Otherwise, it may cause a fire, electrical shock, explosion or injury. • Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit. - If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc. • Always install an circuit breaker and a dedicated disconnect switch. - No installation may cause a fire and electrical shock. • Do not keep or use flammable gases or combustibles near the air conditioner. - Otherwise, it may cause a fire or the failure of product. • Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time. - It may cause injury or an accident. • Do not disassemble or repair the product randomly. - It will cause a fire or electrical shock. • Do not install the product at a place that there is concern of falling down. - Otherwise, it may result in personal injury. • Use caution when unpacking and installing. - Sharp edges may cause injury. • Thickness of copper pipes used are as shown in the “Flaring work” Table. - Never use copper pipes thinner than that in the table even when it is available on the market • Do not use copper pipes that have collapsed. - Otherwise, the expansion valve or capillary tube may become blocked with contaminants. • For R410A model, use piping, flare nut and tools which are specified for R410A refrigerant. - Use of (R22) piping, flare nut and tools may cause abnormally high pressure in the refrigerant cycle (piping), and possibly result in explosion and injury. • It is recommended that the amount of residual oil is less than 40mg / 10m (0.04627oz/ft). • Do not turn on the breaker or power under condition that front panel, cabinet, top cover, and control box cover are removed or opened. - Otherwise, it may cause fire, electric shock, explosion or death. • If the air conditioner is installed in a small room, measures must be taken to prevent the refrigerant concentration from exceeding the safety limit when the refrigerant leaks. - Consult the dealer regarding the appropriate measures to prevent the safety limit from being exceeded. Should the refrigerant leak and cause the safety limit to be exceeded, hazards due to lack of oxygen in the room could result. 75 _ Wall Mounted-60Hz(R410A) Inverter Single 15. Installation • Use a vacuum pump or inert (nitrogen) gas when doing leakage test or air purge. Do not compress air or oxygen and do not use flammable gases. - Otherwise, it may cause fire or explosion. There is the risk of death, injury, fire or explosion. ! CAUTION Installation • Install the drain hose to ensure that drain can easily occur. - Otherwise, it may cause water leakage. • Install the product so that the noise or discharge air from the outdoor unit do not cause any damage to the neighbors. - Otherwise, it may cause dispute with the neighbors. • Always inspect gas leakage after the installation and repair of product. - Otherwise, it may cause the failure of product. • Keep level parallel in installing the product. - Otherwise, it may cause vibration or water leakage. Operation • Avoid excessive cooling ; account for and consider ventilation. - Otherwise, it may do harm to your health. • Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent. - The appearance of the air conditioner may deteriorate, change color, or develop surface flaws. • Do not use the appliance for special purposes such as preserving animals vegetables, precision machine, or art articles. - Otherwise, it may damage your properties. • Do not place obstacles around the air flow inlet or outlet. - Otherwise, it may cause the failure of appliance or an accident. h Safety instructions associated with the power cord only applies to products with the power cord included. Wall Mounted-60Hz(R410A) _ 76 Inverter Single Operation • Do not share the outlet with other appliances. - It will cause an electric shock or a fire due to heat generation. • Do not use a damaged power cord. - Otherwise, it may cause a fire or electrical shock. • Do not modify or extend the power cord. - Otherwise, it may cause a fire or electrical shock. • Take care so that the power cord is pulled during operation. - Otherwise, it may cause a fire or electrical shock. • Unplug the unit if strange sounds, smell, or smoke comes from it. - Otherwise, it may cause electrical shock or a fire. • Keep flames away. - Otherwise, it may cause a fire. • Take the power plug out if necessary, holding the head of the plug and do not touch it with wet hands. - Otherwise, it may cause a fire or electrical shock. • Do not use the power cord near the heating tools. - Otherwise, it may cause a fire and electrical shock. • Do not open the suction inlet of the indoor/outdoor unit during operation. - Otherwise, it may electrical shock and failure. • Do not allow water to run into electrical parts. - Otherwise, it may cause the failure of machine or electrical shock. • Hold the plug by the head when taking it out. - It may cause electric shock and damage. • Never touch the metal parts of the unit when removing the filter. - They are sharp and may cause injury. • Do not step on the indoor/outdoor unit and do not put anything on it. - It may cause an injury through dropping of the unit or falling down. • Do not place a heavy object on the power cord. - Otherwise, it may cause a fire or electrical shock. • When the product is submerged into water, always contact the service center. - Otherwise, it may cause a fire or electrical shock. • Take care so that children do not step on the outdoor unit. - Otherwise, children may be seriously injured due to falling down. Inverter Single 15. Installation Inverter Single Installation Map Installation plate Sleeve Bushing-Sleeve Putty(Gum Type Sealant) Bend the pipe as closely on the wall as possible, but be careful that it doesn't break. Vinyl tape (Wide) Saddle • Apply after carrying out a drainage test. • To carry out the drainage test, remove the air filters and pour water into the heat exchanger. Taping Direction Gas side piping (Optional Parts) Liquid side piping (Optional Parts) Additional drain pipe Air Inlet Air Outlet Base Plate Note • h : You should purchase the installation parts. 77 _ Wall Mounted-60Hz(R410A) Vinyl tape (Narrow) Drain Hose Connecting cable (Optional Parts) Inverter Single 15. Installation Installation parts Part Name MW09C1J / MW12C1J MW09Y3J / MW12Y3J Shape Qty. MW18C3J / MW24C3J MW18Y3J Shape Qty. Installation Plate 1 1 Type "A" Screw (Fix installation plate) 5 5 Type "B" Screw (Fix remote controller holder) 2 2 Type "C" Screw (Fix chassis and installation plate) 2 2 Type "D" Screw (Fix chassis and conduit bracket) - - - - Bracket - - - - Remote Controller Holder Model Name Part Name 1 MW24Y3J / MW30Y3J MW36Y3J Shape 1 MWH12Y3J Qty. Shape Qty. Installation Plate 1 1 Type "A" Screw (Fix installation plate) 8 5 Type "B" Screw (Fix remote controller holder) 2 2 Type "C" Screw (Fix chassis and installation plate) - - 2 Type "D" Screw (Fix chassis and conduit bracket) - - 2 Bracket - - 1 1 1 Remote Controller Holder Wall Mounted-60Hz(R410A) _ 78 Inverter Single Model Name Inverter Single 15. Installation Inverter Single Select the Best Location Indoor unit 1. Keep unit away from any indoor steam or excessive heat. 2. No obstacles should be placed around unit. 3. Condensation drain (leakage piping) should be routed away from the unit. 4. Do not install near doorway. 5. Use a metal detector to locate studs in the walls. Anchor unit following stud location, to prevent damage to the wall. 6. Clearance gap between any wall or enclosure and the left or right side of the unit must be greater than 4 inches (100 mm). 7. Minimum clearance of indoor unit from the top of the unit to the ceiling must be 5 inches (120 mm). 8. Unit should be at least 6.5 feet (2 m) from the floor for adequate clearance. Unit : inch (mm) More than 4 (100) More than 5 (120) More than 4 (100) Outdoor unit 1. When placing the outdoor unit under an overhang, awning, sunroof or other “roof-like structure”, ensures that heat radiation from the condenser is not restricted around the unit. 2. Do not place the unit where animals and/or plants will be in the path of the warm air, or where the warm air and/or noise will disturb neighbors. 3. Sunroof is recommended for installations that are exposed to direct sunlight and for installations in cold climates with heavy snow which can accumulate on top of outdoor unit. 4. Take the weight of the air conditioner into account and select a place where noise and vibration are minimum. 5. Observe the below clearance requirements. Note • Normal clearances are recommended for service and cleaning access. • If you do not meet the minimum clearances for installation, the unit does not guarantee the reliability of the unit. • If the outdoor unit is installed between normal and minimum clearances, capacity can be decreased about 10%. 79 _ Wall Mounted-60Hz(R410A) Inverter Single 15. Installation Outdoor unit service access and allowable clearances Case 1 Case 2 Inverter Single inch s /16 ) or les 1 1 19 0 mm (50 Case 3 inch s /16 ) or les 1 1 19 0 mm (50 G G A D D B C C Case 4 Case 5 D F B E Unit : mm Case1 Case2 Case3 Case4 Case5 Case2 Case3 Case4 Case5 D A B C D E F G Normal 300 600 - 300 - - - Minimum 100 250 - 100 - - 1000 Normal - - 500 - - - - Minimum - - 350 - - - 1000 Normal - - 500 300 - - - Minimum - - 350 100 - - - Normal - - - 300 600 - - Minimum - - - 100 200 2000 - Normal - 600 - 300 - - - Minimum - 250 - 100 - - - A B C D E F G Unit : inch Case1 B Normal 11-13/16 23-19/32 - 11-13/16 - - - Minimum 3-15/16 9-27/32 - 3-15/16 - - 39-3/8 Normal - - 19-11/16 - - - - Minimum - - 13-25/32 - - - 39-3/8 Normal - - 19-11/16 11-13/16 - - - Minimum - - 13-25/32 3-15/16 - - - Normal - - - 11-13/16 23-19/32 - - Minimum - - - 3-15/16 7-7/8 78-3/4 - Normal - 23-19/32 - 11-13/16 - - - Minimum - 9-27/32 - 3-15/16 - - - Wall Mounted-60Hz(R410A) _ 80 Inverter Single 15. Installation Inverter Single Precautions about installation in regions with extreme snowfall and cold temperatures To ensure the outdoor unit operates properly, certain measures are required in locations where there is a possibility of heavy snowfall or severe wind chill or cold : 1. Prepare for severe winter wind chills and heavy snowfall, even in areas of the country where these are unusual phenomena. 2. Position the outdoor unit so that its airflow fans are not buried by direct, heavy snowfall. If snow piles up and blocks the airflow, the system may malfunction. 3. Remove any snow that has accumulated 4 inches (100mm) or more on the top of the outdoor unit. 4. Place the outdoor unit on a raised platform at least 20 inches (500mm) higher than the average annual snowfall for the area. If the frame width is wider than the outdoor unit, snow may accumulate. 5. Install a snow protection hood. 6. To prevent snow and heavy rain from entering the outdoor unit, install the suction and discharge ducts facing away from direct winds. 7. Additionally, the following conditions should be taken into consideration when the unit operates in defrost mode : • If the outdoor unit is installed in a highly humid environment (near an ocean, lake, etc.), ensure that the site is wellventilated and has a lot of natural light. (Example : Install on a rooftop.) 81 _ Wall Mounted-60Hz(R410A) Inverter Single 15. Installation Fixing Installation Plate 1. Mount the installation plate on the wall with type "A" screws. If mounting the unit on a concrete wall, use anchor bolts. • Mount the installation plate horizontally by aligning the centerline using a level gauge. 2. Measure the wall and mark the centerline. It is also important to use caution concerning the location of the installation plate. Routing of the wiring to power outlets is through the walls typically. Drilling the hole through the wall for piping connections must be done safely. Installation Plate Type "A" Screws Chassis Hook MW09C1J / MW12C1J MW09Y3J / MW12Y3J [Unit : inch (mm)] 18-7/8 (480) 16-1/4 (412) Unit Outline Ø2-9/16 (65) Ø2-9/16 (65) Place a level on raised tab Installation Plate Left Rear 5-1/4 (136) Piping Right Rear 4-13/16 (123) Piping 7 (178) 9-5/8 (245) MW18C3J / MW24C3J / MW18Y3J [Unit : inch (mm)] 18-1/8(460) 22-11/32(567) Unit Outline Ø2-9/16(65) Left Rear Piping Place a level on raised tab Ø2-9/16(65) Right Rear Piping Installation Plate 7-1/4(184) 7.24in(184mm) 8-11/16(220) 6-5/32(156) 6.14in(156mm) 12-3/32(307) Wall Mounted-60Hz(R410A) _ 82 Inverter Single The wall you select should be strong and solid enough to prevent vibration Inverter Single 15. Installation MW24Y3J / MW30Y3J / MW36Y3J 6-9/16 (167) 17-7/32 (335) 1-11/16 (43) 33-25/32 (858) 1-11/16 (43) 2-17/32 (Ø65) 4-23/32 (120) 4-23/32 (120) MWH12Y3J [Unit : inch (mm)] 11-5/8 (295) Unit Outline 17 (434) 31/32 (24.6) 1-7/8 (47.5) Place a level on raised tab 17-5/16 (439) Ø2-9/16 (65) Ø2-9/16 (65) Left rear piping 1-31/32 (50) Inverter Single 6-9/16 (167) 2-17/32 (Ø65) [Unit : inch (mm)] Right rear piping 6-11/16 (170) 8-17/32 (217) 4-13/16 (123) 6-29/32 (175) Drill a Hole in the Wall WALL Indoor Bushing Sleeve ! CAUTION • Use a sleeve to prevent damage to the tube assembly. 83 _ Wall Mounted-60Hz(R410A) Outdoor 3/16"~5/16" (5~7 mm) • Drill the piping hole with a Ø 2-9/16 inch (65mm) hole core drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the outdoor side. Inverter Single 15. Installation Flaring Work One cause of gas leakage is improper workmanship in flaring. Carry out correct flaring work in the following procedure. 1. Use the piping kit accessory or the pipes purchased locally. 2. Measure the distance between the indoor and the outdoor unit. 3. Cut the pipes a little longer than measured distance. 4. Cut the cable 1.5m(5ft) longer than the pipe length. Copper pipe Slanted Uneven Rough 90° Burrs removal Pipe 1. Completely remove all burrs from the cut cross section of pipe/tube. 2. While removing burrs put the end of the copper tube/pipe in a downward direction while removing burrs location is also changed in order to avoid dropping burrs into the tubing. Reamer Point down Putting nut on Flare nut • Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal. (not possible to put them on after finishing flare work) Copper tube Flaring work Outside diameter mm inch Ø6.35 1/4 Ø9.52 3/8 Ø12.7 1/2 Ø15.88 5/8 Ø19.05 3/4 Bar Handle "A" 1. Firmly hold copper pipe in a bar with the dimension shown in table below. Bar Yoke A mm 1.1 ~ 1.3 1.5 ~ 1.7 1.6 ~ 1.8 1.6 ~ 1.8 1.9 ~ 2.1 inch 0.043 ~ 0.051 0.059 ~ 0.067 0.063 ~ 0.071 0.063 ~ 0.071 0.075 ~ 0.083 Cone Copper pipe Clamp handle Red arrow mark 2. Carry out flaring work with the flaring tool. Check Smooth all round Inside is shiny without scratches 1. Compare the flared work with the figure by. 2. If a section is improperly flared, cut it off and perform flaring work again. = Improper flaring = Even length all round Inclined Surface Cracked Uneven damaged thickness Wall Mounted-60Hz(R410A) _ 84 Inverter Single Cut the pipes and the cable. Inverter Single 15. Installation Inverter Single Connecting the Piping Indoor unit 1. Pull the screw cap at the bottom of the indoor unit or open the front cover. 2. Remove the chassis cover from the unit by loosing screws. Chassis cover 3. Pull back the tubing holder. Indoor unit back side view Tubing holder 4. Remove pipe port cover and position the tubing. Right Downwards Left Backwards Folding the pipe Good case Bad case • Press on the tubing cover and unfold the tubing to downward slowly. And then bend to the left side slowly. • Following bending case from right to left directly may cause damage to the tubing. ! CAUTION • Secure the pipe by using the tubing cover. • Do not strongly press the refrigerant pipes onto the bottom frame. • Do not strongly press the refrigerant pipes on the front grille, either. 85 _ Wall Mounted-60Hz(R410A) Inverter Single 15. Installation Installation of Indoor Unit Installation plate 2. Unlock the tubing holder from the chassis and mount between the chassis and installation plate in order to separate the bottom side of the indoor unit from the wallwall Tubing Holder Conduit Bracket & Chassis Connection Before bending the tubing, set the conduit like picture below by using the bracket and black screws from accessory kit. View Wall Mounted-60Hz(R410A) _ 86 Inverter Single 1. Hook the indoor unit onto the upper portion of the installation plate.( engage the three hooks at the top of the indoor unit with the upper edge of the installation plate) Ensure that the hooks are properly seated on the installation plate by moving it left and right Inverter Single 15. Installation Inverter Single Piping 1. Insert the connecting cable through the bottom side of indoor unit and connect the cable (You can see detail contents in 'Connecting the cables' section) 2. Secure the cable onto the control board with the cable retainer. Control Cover 1(L1) 2(L2) 3 1(L1) 2(L2) 1(L1) 2(L2) 3 3 1(L1) 2(L2) 3 Cord clamp Power connecting cable 3. Tape the tubing pipe, drain hose and the connection cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause overflow from the drain pan through the inside of the unit. Be sure to install in the sequence of Connecting cable (Conduit), Drain hose and Connecting pipe as the picture below describes. Tape Connecting cable(conduit Taping Tape Connecting cable(conduit) Drain hose Connecting pipe Taping 87 _ Wall Mounted-60Hz(R410A) Drain hose Connecting pipe Inverter Single 15. Installation ! CAUTION Indoor * Insert the drain hose more than 1-15/16” (50mm) so it won’t be pulled out of the drain pipe. Outdoor Indoor Unit Drain hose Insulation Extension drain hose Indoor Unit Drain hose Insert the drain hose to this depth so it won’t be pulled out of drain pipe. Inner wall Drain Hose 1-15/16” (500mm) or more Vinyl chloride drain pipe (VP-30) Outer wall Connecting the installation pipe and drain hose to the indoor unit. 1. Align the center of the pipes and sufficiently tighten the flare nut by hand Indoor unit tubing Flare nut Pipes 2. Tighten the flare nut with a wrench Outside diameter mm Ø6.35 Ø9.52 Ø12.7 Ø15.88 inch 1/4 3/8 1/2 5/8 Torque kgf.m 1.8~2.5 3.4~4.2 5.5~6.6 6.3~8.2 lbf.ft 13~18 24.6~30.4 39.8~47.7 45.6~59.3 3. When needed to extend the drain hose of indoor unit, assembly the drain pipe as shown on the drawing Open-end wrench (fixed) Flare nut Wrench Connection pipe Indoor unit tubing Drain pipe Indoor unit drain hose Adhesive Vinyl tape(narrow) Wall Mounted-60Hz(R410A) _ 88 Inverter Single If the extension drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from sweating (condensation) could not damage furniture or floors. • Foamed polyethylene or equivalent is recommended. • Insulation should be more than 3-15/16” ~ 11-13/16” (100~300mm) length and 9/32” (7mm) thickness. • Insert the drain hose more than 1-15/16” (50mm) so it won’t be pulled out of the drain pipe. Inverter Single 15. Installation Inverter Single Wrap the insulation material around the connecting portion. Insulation material 1. Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there may be no gap. Cutting Line 2. Set the tubing cutting line upward. Wrap the area which accommodates the rear piping housing section with vinyl tape. Gas Pipe Liquid Pipe Good Case Cutting Line Bad Case * Tubing cutting line have to be upward. Indoor unit pipe Connection pipe h both refrigerant pipes (liquid and gas) must be insulated between the ODU and IDU, not just the connection. Wrap with vinyl tape Vinyl tape (wide) Connecting cable Pipe Vinyl tape(narrow) 3. Bundle the piping and drain hose together by wrapping them with vinyl tape sufficient enough to cover where they fit into the rear piping housing section. Wrap with vinyl tape Pipe Vinyl tape(wide) Drain hose Finishing the indoor unit installation 1. Mount the tubing holder in the original positon. 2. Ensure that the hooks are properly seated on the installation plate by moving it left and right. 3. Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots (clicking sound). 4. Finish the assembly by screwing the unit to the installation plate by using two pieces of type "C" screws. And assemble a chassis cover. ! CAUTION • Before finishing installation of the indoor unit, seal the hole of a wall except the pipe’s ways to prevent condensate from inflow of outdoor air. 89 _ Wall Mounted-60Hz(R410A) Type 'C' screw Inverter Single 15. Installation Outdoor unit Tubing cover Terminal Block Cover control Tubing Cover Wall Mounted-60Hz(R410A) _ 90 Inverter Single 1. Remove the tubing cover from the unit by loosening the screw. Inverter Single 15. Installation Inverter Single 2. Align the center of the pipings and sufficiently tighten the flare nut by hand. 3. Finally, tighten the flare nut with torque wrench until the wrench clicks. Outdoor unit • When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench. Outside diameter mm Ø6.35 Ø9.52 Ø12.7 Ø15.88 Ø19.05 inch 1/4 3/8 1/2 5/8 3/4 Liquid side piping (Smaller diameter) Torque kgf.m lbf.ft 1.8~2.5 13~18 3.4~4.2 24.6~30.4 5.5~6.6 39.8~47.7 6.3~8.2 45.6~59.3 9.9~12.1 71.6~87.5 Torque wrench Gas side piping (Bigger diameter) Outdoor unit Gas side piping (Bigger diameter) Liquid side piping (Smaller diameter) Torque wrench 91 _ Wall Mounted-60Hz(R410A) Inverter Single 15. Installation Connecting the Cables Connect the cable to the indoor unit by connecting the wires to the terminals on the control board individually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No. are the same as those of the indoor unit.) ! CAUTION • The circuit diagram is a subject to change without notice. • The earth wire should be longer than the common wires. • When installing, refer to the circuit diagram on the control cover. • Connect the wires firmly so that they may not be pulled out easily. • Connect the wires according to color codes, referring to the wiring diagram. • Connect the wires should be sized per local code. Outdoor unit - Connect the wires to the terminals on the control board individually. - Secure the cable onto the control board with the cord clamp. - Use a recognized circuit breaker between the power source and the unit. - A disconnecting device to adequately disconnect all supply lines must be fitted. - Provide a circuit breaker between power source and the outdoor unit as shown below. ! CAUTION Provide the circuit breaker between power source and the unit as shown by. Circuit Breaker A MR09Y3J / MR12Y3J MRH12Y3J 15 Model MR09C1J / MR12C1J MR18C3J / MR18Y3J 20 Main power source MR24C3J 30 MR24Y3J / MR30Y3J MR36Y3J 35 Air Conditioner Circuit Breaker Use a circuit breaker or time delay fuse. ! CAUTION The power cord connected to the outdoor unit should be complied with the following specifications. (UL recognized or CSA certified). “ 1/8 32± ) 13/ ±3 mm (10 AWG_"A" Model Power Supply Power supply cable (208/230V) GN /YL "A" MR09Y3J / MR12Y3J MR09C1J / MR12C1J MR24C3J / MR24Y3J MRH12Y3J MR18C3J / MR18Y3J MR30Y3J / MR36Y3J 18 14 12 13 (20 /16” mm ) Wall Mounted-60Hz(R410A) _ 92 Inverter Single Indoor unit Inverter Single 15. Installation Inverter Single The power and transmission cable connected to the indoor and outdoor unit should be complied with the following specifications (UL recognized or CSA certified). AWG_"B" Connecting cable (208/230V) “ 1/8 32± ) 13/ ±3 mm (10 Power Supply / Communication "B" GN /YL Capacity (Btu/h) 9 ~ 36k 18 13 (20 /16” mm ) h Field wiring shall be done such that the current carrying conductors become taut before the earthing conductor if the cord slips out of the cord anchorage. ! CAUTION When using the separate wire as the power cord, please fix the separate wire into the control box panel by using tie wrap as the fixture. 93 _ Wall Mounted-60Hz(R410A) Inverter Single 15. Installation Assembling the conduit Assemble it with conduit. Inverter Single 1. Remove the cover control from the unit by loosening the screw. Connect the wires to the terminals on the control board individually as the following. 2. Secure the cable onto the control board with the holder (clamper). 3. Refix the cover control to the original position with the screw. Terminal block Over 0.2” (5mm) Connecting cable Power supply cord Conduit panel Tubing cover 1(L1) 2(L2) 1(L1) 2(L2) 3 Outdoor unit Terminal block Over 0.2” (5mm) Power supply cord Conduit panel Connecting cable Cover control Wall Mounted-60Hz(R410A) _ 94 Inverter Single 15. Installation Inverter Single Note 1. Separately wire power supply cord and connecting cable. 2. Use heat-proof electrical wiring capable of withstanding temperature up to 167°F (75°C). 3. Use outdoor and waterproof connection cable rated up to 300V for the connection between indoor and outdoor unit. (For example, Type SJO-WA) ! WARNING • Be sure to comply with local codes while running the wire from the indoor unit to the outdoor unit(size of wire and wiring method, etc). • Every wire must be connected firmly. • No wire should be allowed to touch refrigerant tubing, the compressor or any moving parts. ! CAUTION According to the confirmation of the above conditions, prepare the wiring as follows. 1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2. The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.) 3. Specification of power source. 4. Confirm that electrical capacity is sufficient. 5. See that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate. 6. Confirm that the cable thickness is as specified in the power source specification. (Particularly note the relation between cable length and thickness. 7. Always install an earth leakage circuit breaker in a wet or moist area. 8. The following would be caused by voltage drop. • Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal function of the overload. 9. The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active(phase) conductors. 95 _ Wall Mounted-60Hz(R410A) Inverter Single 15. Installation Wiring diagram M09YJ, M12YJ Outdoor Unit 1(L) 2(N) Terminal 5P 3 Disconnect Switch Grounding Line Power Supply 1 Phase 208/230 VAC Connecting cable Indoor Unit Terminal 3P 1(L) 2(N) 3 Power Supply 1 Phase 208/230 VAC Connecting cable Indoor Unit Terminal 3P 3 M18CJ, M24CJ, M18YJ 1(L1) 2(L2) 3 M24YJ, M30YJ, M36YJ Outdoor Unit Connecting cable Indoor Unit 1(L1) 2(L2) Power Supply 1 Phase 208/230 VAC Connecting cable Indoor Unit Terminal 4P 3 1(L1) 2(L2) 3 Grounding Line Disconnect Switch Grounding Line Power Supply 1 Phase 208/230 VAC Terminal 4P 1(L1) 2(L2) Grounding Line 1(L1) 2(L2) 3 Grounding Line 1(L1) 2(L2) Terminal 10P Disconnect Switch Outdoor Unit Terminal 8P 1(L1) 2(L2) 1(L1) 2(L2) Grounding Line N Grounding Line L Disconnect Switch Grounding Line Outdoor Unit Terminal 5P 1(L1) 2(L2) 3 HM12YJ Outdoor Unit 1(L1) 2(L2) 1(L1) 2(L2) 3 Disconnect Switch Grounding Line Grounding Line Terminal 8P Power Supply 1 Phase 208/230 VAC Connecting cable Indoor Unit Terminal 3P 1(L1) 2(L2) 3 Note • A field installed disconnect switch should be required. Check the local code. Wall Mounted-60Hz(R410A) _ 96 Inverter Single M09CJ, M12CJ Inverter Single 15. Installation Inverter Single Checking the Drainage To check the drainage. 1. Pour a glass of water on the evaporator. 2. Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. Connecting area drain hose Leakage checking Drain pan Drain hose Leakage checking Drain piping 1. The drain hose should point downward for easy drain flow. 97 _ Wall Mounted-60Hz(R410A) Downward slope Inverter Single 15. Installation 2. Do not make drain piping like the following. Water leakage Water leakage Less than 1-15/16” (50 mm) gap Risen tip of drain hose Tip of drain hose dipped in water Water leakage Waving Ditch No rainwater trap Tip of drain hose dipped in bottle Drain hose inserted less than 1-15/16” (50 mm) in buried pipe Tip of drain hose and ground are parallel Buried pipe Less than 1-15/16” (50 mm) gap Taping Direction Horizontal drain hose more than 6.6 ft (2 m) Wall Mounted-60Hz(R410A) _ 98 Inverter Single Accumulated drain water Air Do not raise Inverter Single 15. Installation Inverter Single Installing Drain Piping of the Outdoor Unit Depending on installation site, it may be required to install drain plug for drainage(Supplied with the unit). In cold areas, do not use a drain hose With the outdoor unit. Otherwise, drain water may freeze, impairing the heating performance. 1. See the figure below for installation of the drain plug. A : Drain connection B : Drain cap C : Drain washer 2. Connect a field supplied vinyl hose to the drain connection (A). If the hose is too long and hangs down, fix it carefully to prevent kinks. MR18C3J / MR18Y3J / MR24C3J MR24Y3J / MR30Y3J / MR36Y3J MRH12Y3J MR09C1J / MR12C1J MR09Y3J / MR12Y3J A B B B C B C B B B 99 _ Wall Mounted-60Hz(R410A) B A Inverter Single 15. Installation Forming the Piping 1. Tape the piping, drain hose and connecting cable from down to up. Seal the small openings around pipings with a gum type sealants. Connecting cable (Conduit) Saddle Pipings 2. Secure the tapped piping along the exterior wall using saddle or equivalent. Taping Drain hose Trap is required to prevent water from entering into electrical parts. In cases where the outdoor unit is installed above the indoor unit perform the following. Seal the small openings around pipings with a gum type sealants. 1. Tape the piping and connecting cable from down to up. 2. Secure the taped piping along the exterior wall. Form a trap to prevent water entering the room. Trap 3. Fix the piping onto the wall using saddle or equivalent. Trap Wall Mounted-60Hz(R410A) _ 100 Inverter Single In cases where the outdoor unit is installed below the indoor unit perform the following. Inverter Single 15. Installation Inverter Single Air Purging The air and moisture remaining in the refrigerant system have undesirable effects as indicated below. 1. Pressure in the system rises. 2. Operating current rises. 3. Cooling(or heating) efficiency drops. 4. Moisture in the refrigerant circuit may freeze and block capillary tubing. 5. Water may lead to corrosion of parts in the refrigeration system. Therefore, after evacuating the system, take a leak test for the piping and tubing between the indoor and outdoor unit. Air purging with vacuum pump 1. Preparation • Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note that both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage. 2. Leak test • Connect the manifold valve(with pressure gauges) and dry nitrogen gas cylinder to this service port with charge hoses. ! CAUTION Be sure to use a manifold valve for air purging. If it is not available, use a stop valve for this purpose. The knob of the 3-way valve must always be kept close. - Pressurize the system to maximum 250 P.S.I.G. (R-22 model) or 400 P.S.I.G. (R-410A model) with dry nitrogen gas and close the cylinder valve when the gauge reading reaches 250 P.S.I.G. (R-22 model) or 400 P.S.I.G. (R-410A model). Next step is leak test with liquid soap. ! CAUTION To avoid nitrogen entering the refrigerant system in a liquid state, the top of the cylinder must be higher than its bottom when you pressurize the system. Usually, the cylinder is used in a vertical standing position. 1. Do a leak test of all joints of the tubing(both indoor and outdoor) and both gas and liquid side service valves. Bubbles indicate a leak. Be sure to wipe off the test solution with a clean cloth. 2. After the system is found to be free of leaks, relieve the nitrogen pressure by loosening the charge hose connector at the nitrogen cylinder. When the system pressure is reduced to normal, disconnect the hose from the cylinder. 101 _ Wall Mounted-60Hz(R410A) Indoor unit Manifold valve Pressure gauge Lo Hi Charge hose Nitrogen gas cylinder(in vertical standing position) Outdoor unit Inverter Single 15. Installation Soap water method Liquid side Gas side 2-way valve (Close) Cap Evacuation 1. Connect the charge hose end described in the preceding steps to the vacuum pump to evacuate the tubing and indoor unit. Confirm the "Lo" knob of the pressure Gauge is open. Then, run the vacuum pump. The operation time for evacuation varies with tubing length and capacity of the pump. The following table shows the time required for evacuation. 3-way valve (Close) Indoor unit Required time for evacuation when 30 gal/h vacuum pump is used If tubing length is If tubing length is less than 10m (33 ft) longer than 10m (33 ft) 10 min. or more 15 min. or more 2. When the desired vacuum is reached, close the knob of the 3-way valve and stop the vacuum pump. Finishing the job 1. With a service valve wrench, turn the valve of liquid side counter-clockwise to fully open the valve 2. Turn the valve of gas side counter clockwise to fully open the valve 3. Loosen the charge hose connected to the gas side service port slightly to release the pressure, then remove the hose. 4. Replace the flare nut and its bonnet on the gas side service port and fasten the flare nut securely with an adjustable wrench. This process is very important to prevent leakage from the system 5. Replace the valve caps at both gas and liquid side service valves and fasten them tight. This completes air purging with a vacuum pump. 6. Replace the pipe cover to the outdoor unit by one screw. Now the air conditioner is ready for test run. Outdoor unit Manifold valve Pressure gauge Lo Hi Open Close Vacuum pump Wall Mounted-60Hz(R410A) _ 102 Inverter Single 1. Remove the caps from the 2-way and 3-way valves. 2. Remove the service-port cap from the 3-way valve. 3. Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor unit connections by a soft brush to check for leakage of the connecting points of the piping. 4. If bubbles come out, the pipes have leakage. Inverter Single 15. Installation Inverter Single Test Running 1. Check that all tubing and wiring are properly connected. 2. Check that the gas and liquid side service valves are fully open. Prepare remote controller 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (–) of battery are installed correctly. 3. Reattach the cover by pushing it back into position. Note • Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries. • Remove the batteries from the remote controller if the system is not used for a long time. Settlement of outdoor unit 1. Fix the outdoor unit with a bolt and nut(ø10mm) tightly and horizontally on a concrete or rigid mount. 2. When installing on the wall, roof or rooftop, anchor the mounting base securely with a nail or wire assuming the influence of wind and earthquake. 3. If the vibration of the unit is transmitted to the pipe, secure the unit with an anti-vibration rubber. 103 _ Wall Mounted-60Hz(R410A) Bolt Tubing connection Inverter Single 15. Installation Foundation For good drain of outdoor unit, keep the bottom height from icing upward. Inverter Single B or more C A Unit : mm Model MR09C1J, MR12C1J, MR09Y3J, MR12Y3J MR18C3J, MR18Y3J, MRH12Y3J MR24C3J, MR24Y3J, MR30Y3J, MR36Y3J Tool UL2 UE UE1+ A 558 546 546 Unit : inch Model MR09C1J, MR12C1J, MR09Y3J, MR12Y3J MR18C3J, MR18Y3J, MRH12Y3J MR24C3J, MR24Y3J, MR30Y3J, MR36Y3J Tool UL2 UE UE1+ A 22 21-1/2 21-1/2 Foundation B C 100 370 100 370 100 370 Material SAZCC SAZCC SAZCC Leg Thickness 1.2 1.6 1.6 Foundation B C 3-15/16 14-19/32 3-15/16 14-19/32 3-15/16 14-19/32 Material SAZCC SAZCC SAZCC Leg Thickness 1/16 3/32 3/32 Bolt construction work Unit : inch (mm) Mechanical anchor bolt M10 2-3/8~4-3/32 (60~120) 25/32 (20) Diagram of lower surface Wall Mounted-60Hz(R410A) _ 104 Inverter Single 15. Installation Inverter Single Evaluation of the performance Operate the unit for 15~20 minutes, then check the system refrigerant charge: 1. Measure the pressure of the gas side service valve. 2. Measure the air temperature from inlet and outlet of air conditiioner. 3. Ensure the difference between the inlet and outlet temperature is more than 8°C(14.4°F). 4. For reference; the gas side pressure at optimum condition is shown on table (cooling) The air conditioner is now ready to use. Refrigerant Outside ambient TEMP. R-410A 35°C (95°F) Return temperature Supply air Supply temperature The pressure of the gas side 8.5~9.5kg/cm2G (120~135 P.S.I.G.) Note If the actual pressure is higher than shown, the system is most likely over-charged, and charge should be removed. If the actual pressure are lower than shown, the system is most likely undercharged, and charge should be added. 105 _ Wall Mounted-60Hz(R410A) Inverter Single 15. Installation Pump down Inverter Single This is performed when the unit is relocated or the refrigerant circuit is serviced. Pump Down means collecting all refrigerant into the outdoor unit without the loss of refrigerant. ! CAUTION Be sure to perform Pump Down procedure in the cooling mode. Pump down procedure 1. Connect a low-pressure gauge manifold hose to the charge port on the gas side service valve. 2. Open the gas side service valve halfway and purge the air in the manifold hose using the refrigerant. 3. Close the liquid side service valve(all the way). 4. Turn on the unit's operating switch and start the cooling operation. 5. When the low-pressure gauge reading becomes 1 to 0.5kg/cm2 G(14.2 to 7.1 P.S.I.G.), fully close the gas side valve and then quickly turn off the unit. Now Pump Down procedure is completed, and all refrigerant is collected into the outdoor unit. Check test items Test Items 1 Indoor unit is hooked to the installation plate properly. 2 The gas and liquid service valves are fully opened. 3 There is no refrigerant gas leakage. 4 System is properly grounded.(No electrical leakage) 5 The connection cable is clamped firmly. 6 Indoor unit receives remote control commands and operates properly. 7 Cooling/Heating operation is normal. 8 There is no abnormal sound. 9 There is no water leakage. Check Wall Mounted-60Hz(R410A) _ 106 Inverter Single 15. Installation Inverter Single Installation Guide for Areas Exposed to Sea Wind ! CAUTION 1. Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced. 2. Do not install the product where it could be exposed to sea wind (salty wind) directly. It can result corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient performance. 3. If outdoor unit is installed close to the seaside, it should avoid direct exposure to the sea wind. Otherwise it needs additional anticorrosion treatment on the heat exchanger. Selecting the location(Outdoor unit) 1) If the outdoor unit is to be installed close to the seaside, direct exposure to the sea wind should be avoided. Install the outdoor unit on the opposite side of the sea wind direction. Sea wind Sea wind 2) In case, to install the outdoor unit on the seaside, set up a windbreak not to be exposed to the sea wind. Windbreak Sea wind - It should be strong enough like concrete to prevent the sea wind from the sea. - The height and width should be more than 150% of the outdoor unit. - Keep more than 2.3ft of space between outdoor unit and the windbreak for easy air flow. 3) Select a well-drained place. 1. If you can’t meet above guide line in the seaside installation, please contact LG Electronics for the additional anticorrosion. 2. Periodic ( more than once/year ) cleaning of the dust or salt particles stuck on the heat exchanger by using water. * Do not use seawater you clean up the heat exchanger 107 _ Wall Mounted-60Hz(R410A) Inverter Single 15. Installation Outdoor Unit Cabin Max15° (Recommended) 1. Outdoor cabin type : Manual door open type 2. Louver angle : Less than 15° on the horizontal base 3. Louver interval: Over 3-15/16 inch (100 mm) (Recommend) Louver 4. Louver shape : Wing type or plane type Inverter Single Outdoor cabin louver requirement Over 3-15/16 inch (100 mm) (Recommended) Section ! CAUTION • Opening rate and suction should be considered for louvered outdoor room. • Do not use 'S' type louver. Outside Noise can occur due to the backward flow of the air passing through the louver blade Inside Note The problem in case the louver opening rate is small. 1. Noise can occur due to the increased velocity of the air passing through louver blade. 2. Noise can occur due to the louver blade vibrations. 3. Drop in outdoor fan performance (Excess static pressure damage can cause drop in the performance as well as outdoor heat exchange efficiency). 4. In case the louver opening rate is small or there is insufficient air flow exchange, it might stop the air conditioner. Opening rate by louver radian W h ho H < 15° ho = h * COS Total face area(A) = H * W Number of open space (N) = (number of louver - 1) Effective face area(Af) = ho * W * N Louver opening rate (n) = Af/A Af = A * n Effective face area of cross section [Side view] [Front view] Wall Mounted-60Hz(R410A) _ 108 Inverter Single 15. Installation Inverter Single Outdoor Unit Max External Static Pressure Model Tool Air Flow Rate Static Pressure CMM CFM N/m2 inWG MR09C1J, MR12C1J, MR09Y3J, MR12Y3J UL2 33.0 1165 8.2049 0.0329 MR18C3J, MR18Y3J, MRH12Y3J UE 50.0 1766 14.4679 0.0581 UE1+ 60.0 2119 9.5635 0.0384 MR24C3J, MR24Y3J, MR30Y3J, MR36Y3J 109 _ Wall Mounted-60Hz(R410A) Friedrich Air Conditioning Co. I 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 www.friedrich.com P/no. : MFL68100907