6U 20-slot Rackmount Chassis Supporting Quad-system and Redundant Power Supply Features 6U rackmount chassis supports up to 4 multi-systems Front LEDs and audible alarm notifications for system power status, fan operation, HDD status, and temperature monitoring Four 53-CFM cooling fans with filters Various backplane options for up to 20 slots Lockable front door prevents unauthorized access and displays the system status clearly Supports up to four sets of dual USB ports in the front Four reserved COM port openings on the rear panel
RoHS COMPLIANT
2002/95/EC
Specifications Drive Bay Cooling I/O Interface Miscellaneous
Environment
Physical
5.25" 3.5" Fan Air Filters USB Notification LEDs Control Real Panel Temperature Humidity Vibration (5 ~ 500 Hz) Shock Altitude Dimensions (W x H x D) Weight
Front-accessible Internal 4 2 4 (53 CFM each) Yes 2 (default) and up to 4 sets of dual USB ports in the front PWR, HDD, Fan & Temperature Power on/off, system reset and alarm reset switches Four COM openings Operating Non-Operating 0 ~ 40° C (32 ~ 104° F) -20 ~ 60° C (-4 ~ 140° F) 10 ~ 85 % @ 40° C, non-condensing 10 ~ 95 % @ 40° C, non-condensing 1 Grms 2G 10 G (with 11 ms duration, half sine wave) 30 G 0 to 3,048 m (0 ~ 10,000 ft) 482 x 266 x 463 mm (19" x 10.5" x 18") 30.0 kg (66 lb)
Four 53-CFM cooling fans
Max. 20-slot backplane
Easy-to-replace fan filter
Up to four sets of dual USB ports
Power LED
Rear vents for better airflow
HDD LED Temp. LED FAN LED
Hot-swap redundant power supply
Power status
Four COM port openings
All product specifications are subject to change without notice
Last updated : 1-Mar-2007
IPC-622 Dimensions
Unit: mm (inch)
Power Supply Options Part Number
Watt
Input
1757000193G (single P/S)
400 W (ATX, PFC)
AC 100 ~ 240 V (full-range)
1757000162G (single P/S)
500 W (ATX, PFC)
AC 100 ~ 240 V (full-range)
1757000177G (1+1 redundant)
460 W (ATX, PFC)
AC 100 ~ 240 V (full range)
Accessories Part Number 1701400971 1701400973 1999611000 1999622000
Specifications Output Mini-load +5 V @ 35 A, +3.3 V @ 25 A, +5 V @ 3 A, +12 V @ 30 A, -5 V @ 0.8 A, +12 V @ 1 A, -12 V @ 1 A, +5 Vsb @ 2 A +5 Vsb @ 0.1 A +5 V @ 40 A, +3.3 V @ 30 A, +5 V @ 2.5 A, +12 V @ 32 A, -5 V @ 0.8 A, +12 V @ 1 A, -12 V @ 1 A, +5 Vsb @ 2 A +5 Vsb @ 0.1 A +5 V @ 5 A, +5 V @ 40 A, +3.3 V @ 30 A, +3.3 V @ 1 A, +12 V @ 32 A, -5 V @ 0.8 A, +12 V @ 2.5 A, -12 V @ 1 A, +5 Vsb @ 2 A +5 Vsb @ 0.1 A
Safety
MTBF
UL/TUV/CB/CCC
91,000 hours @ 25° C
UL/TUV/CB/CCC
98,000 hours @ 25° C
UL/TUV/CB/CCC
100,000 hours @ 25° C
Ordering Information Description HDD cable, ATA 33, 62 cm + 35 cm HDD cable, ATA 66/100, 62 cm + 35 cm Door filter 142 x 97 x 5 mm Fan filter 382 x 93 x 5 mm
Part Number
Power Supply Without power supply, IPC-622BP-00RCE with ATX switch IPC-622BP-40ZCE 1757000193G (single P/S) IPC-622BP-50ZCE 1757000162G (single P/S) IPC-622BP-46RCE 1757000177G (1+1 RPS) Black Color Chassis Options Without power supply, IPC-622BP-00RCBE with ATX switch IPC-622BP-46RCBE 1757000177G (1+1 RPS)