Line-rate IP packet capture for 1G and 10G Ethernet links with built-in user-plane analysis
KEY FEATURES High-performance capture system for multiple 10/100 Mbit/s, 1 Gbit/s or 10 Gbit/s Ethernet links 100 % line-rate packet processing with up to 10 Gbit/s capture to disk Record data to HDD–32 TB of local storage; massive external storage options High-resolution (10 ns) time stamping Flexible filtering–set your rules beforehand or extract wanted information afterwards Real-time connection, link and network statistics Multi-user environment Detailed flow analysis with DPI parameters, network visualization and KPI/QoS graphs
(ES) Equipements Scientifiques SA - Département Optique & Télécoms - 127 rue de Buzenval BP 26 - 92380 Garches Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail:
[email protected] - Site Web: www.es-france.com
SPEC SHEET
iPro
iPro
CAPTURE YOUR NETWORK iPro is an ideal tool for telecom, finance, security organizations and IT professionals needing a reliable, high-performance capture and data processing system for 10/100 Mbit/s, 1 Gbit/s or 10 Gbit/s Ethernet networks.
Figure 1. iPro is a network capture system for high-speed Ethernet links.
iPro supports full-line-rate packet filtering and processing even with multiple 10G Ethernet interfaces regardless of packet size. With peak recording speed up to 10 Gbit/s, iPro provides a reliable platform for different IP network operations.
MAXIMUM FLEXIBILITY WITH SIMPLICITY iPro is a non-intrusive, passive capture system that can be used in any Ethernet IP network. iPro can perform network monitoring, troubleshooting and network forensics to help solve problems related to IP flow, transaction analysis and security. iPro can be fully configured, managed and run through either CLI or a Web-based GUI (SSH/HTTPS) via a dedicated control port. Multiple simultaneous users are supported. All data from networks connected to iPro’s ports will be captured to the system memory and may be recorded to internal hard drives. External storage can be made accessible to the system by utilizing industry-standard storage systems such as iSCSI or FC systems. A flexible front-end with SFP/SFP+ modules allows users to connect to different types of interfaces. Data capture parameters can be defined by users, including full-linerate data capture, IP headers only, filtering control-plane data for LTE, Iub or Gb traffic, specified packet length and other BPF packet filtering criteria. Once defined, data is filtered and recorded to local storage using configurable sequenced recording options based on time or file size limits. Common PCAP and enhanced PCAP file formats and open interfaces allow flexible integration to open standards-based applications and post-processing. iPro timestamps every captured packet to 10 ns, providing extremely accurate timestamp resolution for the most demanding applications. Multiple iPro systems can be synchronized by using NTP or GPS clock sources. Each captured IP connection can be presented in the iPro’s GUI, which includes throughput graphs and tables, with common net-flow parameters. Users can select or aggregate individual connections and extract data for further analysis. Real-time statistics are also provided for network health monitoring. iPro can also play back the capture files. Recorded network events can be transmitted back to Ethernet with adjustable packet rate, allowing users to reproduce past network situations.
Figure 2. iPro’s easy-to-use GUI presents the system load and network statistics.
iPro
USER-PLANE ANALYSIS The optional Diagnostics Suite client application, when runs on a separate PC, allows reading of ready-flow records from the iPro IP Session Flow and QoS Analysis database. It can easily point interesting network flows, sessions and conversations as all data is visualized in different tables where flows can be filtered, grouped or sorted. With the Diagnostics Suite application, users can analyze individual IP flows and provide information such as the source and destination IP addresses, ports, protocols, locations, origins, throughput, amount of transferred data values, etc. Users can also see information such as VLAN tags, Q-in-Q, MPLS, GTP TEIDs as well as the flow data for tunneled IP connections that are especially used in mobile networks like PS Core and LTE. The Diagnostics Suite application provides GTP-C session information for LTE and Gn interfaces such as call parameters, bearer information, call duration and message statistics. The Diagnostics Suite application also provides advanced quality of service (QoS) and key performance indicator (KPI) graphs including charts and diagrams for statistics and traffic distribution and throughput per individual or aggregated flows and sessions. Administrators can easily follow up bandwidth usage for specific connections. As for QoS and service-level agreement (SLA) measurements, graphs are available for the most important QoS KPIs, such as throughput and jitter. Moreover, Diagnostics Suite enables maximum analysis accuracy of applications with the use of deep packet inspection technology, enabling application identification and classification with key parameters provided for each application as well. Application quality measurements are easily performed with pre-defined QoS analysis views, e.g., for subscriber’s quality of experience (QoE), top websites, web traffic QoS and audio/ video analysis.
Figure 3. Visualizing network traffic with the Diagnostics Suite application
SYSTEM OPTIONS iPro can be configured according to various environments. Different capture system configurations are available; iPro can also be customized with additional software options or hardware modules.
PROBES Items
iPro 1040-1
iPro 1040-4
iPro 1200-4
Interfaces
Two 10/100 Mbit/s and 1 Gbit/s Ethernet
Two 10/100 Mbit/s and 1 Gbit/s Ethernet
Two 10 Gbit/s Ethernet
Memory
4 GB
4 GB
4 GB
Processor
Intel Xeon Quadcore E5220 2.26 GHz
Intel Xeon Quadcore E5220 2.26 GHz
Intel Xeon Quadcore E5220 2.26 GHz
Local Storage
1 TB (SATA2)
4 TB (4 x 1 TB SATA2)
4 TB (4 x 1 TB SATA2)
Size
1U
1U
1U
iPro
SYSTEM OPTIONS (CONTINUED)
PROBES Items
iPro 2040-8
iPro 3040-32
iPro 3200-16
iPro 3200-32
Interfaces
Four 10/100 Mbit/s and 1 Gbit/s Ethernet
Four 1 Gbit/s Ethernet
Two 10 Gbit/s Ethernet
Two 10 Gbit/s Ethernet
Memory
96 GB
96 GB
96 GB
96 GB
Processor
Two Intel Xeon X5670 six-core 2.93 GHz
Two Intel Xeon X5670 six-core 2.93 GHz
Two Intel Xeon X5670 six-core 2.93 GHz
Two Intel Xeon X5670 six-core 2.93 GHz
Local Storage
8 TB (8 x 1 TB SAS)
32 TB (16 x 2 TB SAS)
16 TB (16 x 1 TB SAS)
32 TB (16 x 2 TB SAS)
Size
2U
3U
3U
3U
OPTIONAL ITEMS IP Session Flow and QoS Analysis
Internal database for storing generated enhanced flow records with QoS KPIs
Diagnostics Suite
Windows SW client for detailed flow analysis with DPI parameters, network visualization and KPI/QoS graphs; requires the IP Session Flow and QoS Analysis option
Deep Packet Inspection
Detailed application level analysis engine option
External Storage
Additional storage options
GPS Synchronization
GPS time synchronization module
Capture Playback
Capture file playback
iPro
TECHNICAL SPECIFICATIONS HARDWARE AND SYSTEM
1U, 2U or 3U rackmount server Two or four SFP or RJ-45 interfaces - IEEE 802.3-compliant RJ-45 ports for 10/100/1000 Mbit/s Ethernet - MSA-compliant SFP modules: 1000BASE-SX (LC), 1000BASE-LX (LC), 1000BASE-T (RJ-45) Two 10 Gbit/s SFP+ interfaces Up to 32 TB for packet capture Separate system disk for system and applications Dual fail-safe power supply Ubuntu 64-bit Server Edition Linux operating system Watchdog functionality for hardware Full system recovery
PACKET CAPTURE TO DISK
10 ns timestamp resolution NTP time synchronization Pcap file format Ingress NetFlow collection (NetFlow v9) IPSec packet decryption
PACKET FILTERING
BPF syntax for filter rules Control- and user-plane filtering for LTE, Iub or Gb interfaces IP header filtering Packet payload filtering Packet stripping Logical expressions Alarms and traps (bandwidth detection or BPF filters)
IP SESSION FLOW AND QOS ANALYSIS DATABASE
Throughput, delay and packet counters for: - MAC and IP layers (SRC/DST) - All transmission level protocols (ICMP, IGMP, TCP, EGP, IGP, UDP, DCCP, RSVP, GRE, ESP, OSPF, SCTP, etc.) - Application level protocols (HTTP, FTP, TELNET, SMTP, DNS, DHCP, POP3, IMAP4, SNMP, RIP2, RTSP, Diameter, Ping, SIP, etc.) - Tunneled connections (GTP TEID, tunneled IPs, protocols, ports, etc.) - Transmission level identifiers (VLAN, MPLS, Q-in-Q) Additional KPIs for: - TCP round-trip time, TCP round-trip jitter, TCP retransmission ratio
DIAGNOSTICS SUITE CLIENT FOR USER-PLANE ANALYSIS Flow view functions Enhanced NetFlow records format including: - Geographical location information, organization, etc. (based on GeoIP database) - Source and destination addresses, ports, protocols - VLAN ID, Q-in-Q, MPLS labels - DNS name resolving - Application protocol, throughput, transferred data - DPI-based parameters - MAC addresses - Full support for tunneled IPs (GTPu, TEID, mobile IPs) - Volume of data sent/received - Number of sent/received packets - Flow timing details - Alias names Advanced filter editor Flexible filtering, sorting and grouping for flows Drill-down from flow level to packet payload Fetch the session specific packet in pcap format from iPro Topology view functions Data traffic between network nodes visualized in a 2D topology view Shows geographical location of network nodes in a map view with color codes visualizing each country’s volume of transferred data QoS measurement view functions Fully configurable charts and graphs for selected flows and network KPIs - Throughput, jitter, counter graphs for individual or aggregated sessions - Transport and application level measurements Top talkers, traffic distribution charts for all data or per endpoint
CONFIGURATION
Web-based GUI: - Multi-user authentication and management - HTTP/HTTPS SSH terminal connection Configurable SNMP traps and alarms Remote server management and updates: - IPMI v2.0 interface - Wake-up on LAN
CAPTURE FILE PROCESSING
Web GUI file manager Samba file share SCP and FTP Automatic file transfer Capture file online reading with M5 Analyzer software
CAPTURE FILE PLAYBACK Adjustable pcap file transmission
ENVIRONMENTAL SPECIFICATIONS Operating temperature: 10 °C to 50 °C Operating relative humidity: 20 % to 80 % Certifications: RoHS, UL, CE (EU), FCC (USA), CSA (Canada), VCCI (Japan), C-TICK (Australia)
PHYSICAL MEASUREMENTS
1U Size (H x W x D): 43 mm x 437 mm x 650 mm (1.7 in x 17.2 in x 25.6 in) Weight: 17 kg (37 lb) 2U Size (H x W x D): 89 mm x 437 mm x 648 mm (3.5 in x 17.2 in x 25.5 in) Weight: 22.7 kg (50 lb) 3U Size (H x W x D): 132 mm x 437 mm x 648 mm (5.2 in x 17.2 in x 25.5 in) Weight: 32.7 kg (72 lb)
POWER CONSUMPTION
iPro 1040-1, iPro 1040-4: 0.75A /173W iPro 1200-4: 0.88A /203W iPro 2040-8: 1.13A /261W iPro 3200-16, iPro 3200-32: 2.28A /526W
EXFO Corporate Headquarters > 400 Godin Avenue, Quebec City (Quebec) G1M 2K2 CANADA | Tel.: +1 418 683-0211 | Fax: +1 418 683-2170 |
[email protected] Toll-free: +1 800 663-3936 (USA and Canada) | www.EXFO.com EXFO America EXFO Asia EXFO China EXFO Europe EXFO Finland EXFO Service Assurance
3400 Waterview Parkway, Suite 100 100 Beach Road, #22-01/03 Shaw Tower 36 North, 3rd Ring Road East, Dongcheng District Room 1207, Tower C, Global Trade Center Omega Enterprise Park, Electron Way Elektroniikkatie 2 270 Billerica Road
Richardson, TX 75080 USA SINGAPORE 189702 Beijing 100013 P. R. CHINA
Tel.: +1 972 761-9271 Tel.: +65 6333 8241 Tel.: + 86 10 5825 7755
Fax: +1 972 761-9067 Fax: +65 6333 8242 Fax: +86 10 5825 7722
Chandlers Ford, Hampshire S053 4SE ENGLAND FI-90590 Oulu, FINLAND Chelmsford, MA 01824 USA
Tel.: +44 23 8024 6810 Tel.: +358 (0)403 010 300 Tel.: +1 978 367-5600
Fax: +44 23 8024 6801 Fax: +358 (0)8 564 5203 Fax: +1 978 367-5700
EXFO is certified ISO 9001 and attests to the quality of these products. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. EXFO has made every effort to ensure that the information contained in this specification sheet is accurate. However, we accept no responsibility for any errors or omissions, and we reserve the right to modify design, characteristics and products at any time without obligation. Units of measurement in this document conform to SI standards and practices. In addition, all of EXFO’s manufactured products are compliant with the European Union’s WEEE directive. For more information, please visit www.EXFO.com/recycle. Contact EXFO for prices and availability or to obtain the phone number of your local EXFO distributor. For the most recent version of this spec sheet, please go to the EXFO website at www.EXFO.com/specs. In case of discrepancy, the Web version takes precedence over any printed literature. sales contact
[email protected], customer support
[email protected]
SPiPro10G.4AN
© 2012 EXFO Inc. All rights reserved.
2008
Printed in Canada 12/06
(ES) Equipements Scientifiques SA - Département Optique & Télécoms - 127 rue de Buzenval BP 26 - 92380 Garches Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail:
[email protected] - Site Web: www.es-france.com