Preview only show first 10 pages with watermark. For full document please download

Ipro Series

   EMBED


Share

Transcript

iPRO Series Pieve d’Alpago – June 2015 Introduction It is an hardware and software system, dedicated to regulate and control a large number of applications The main characteristic is that it can be programmed by people with experienced in final application but not a specific experience in programming For Dixell, the Programmable Controller project has been designed and developed as a new concept of configurable hardware, looking at the same time to find the best environment to develop applications iPro FAMILY Programmable Digital Controllers Applicable to: REFRIGERATION – RETAIL – BMS – HVAC Markets • Powerful Modular Platform • High Flexibility/Expandibility • High Connectivity • Easy and Useful HMI • Easy and Fast Programming Tools High Flexibility & Expandability iPro FAMILY EEV Driver Expansion Module Connettivity Module High Connectivity High Connectivity iPro FAMILY - Easy and Useful HMI iPro FAMILY Visograph Touch Screen Main Features • • • • • • • CPU: ARM9 200Mhz – LINUX 2.6 Operating System 80 MB of free memory flash – 10 DIN format & IPL 4 MB of free memory flash – 4 DIN format 24 Vac-dc power-supply Up to 10 ANALOG INPUTs Up to 6 ANALOG OUTPUTs Up to 20 DIGITAL INPUTs Up to 15 DIGITAL OUTPUTs The Analog Input and the Analog Output can be configured as Digital Input and Digital Output. About Programmable Controller Structure Visograph & Visotouch iPro Hardware that control the application User interace for the applications Visoprog Software to develop the Visograph & Visotouch application ISaGRAF® VISOPROG Web Server The integrated web server lets the development of a custom website ISaGRAF® Environment to develop the iPro application Function Blocks and Templates Dixell provide a lot of FB usable for applications ARCHITECTURE AND DEVELOPMENT TOOLS iPro RANGE • IPG series Programmable version 10 or 4 DIN rail No application inside • IPC series Chiller – Heat Pump application Dixell application • IPR series Rack Controller application Dixell application • IPL series Programmable connectivity module No application inside • IPX series Expansion Modules 10 or 4 DIN rail iPro RANGE iPRO Programmable Controllers iPro GENIUS iPro CHILL iPro LINK iPro RACK IPG115D IPG215D IPG315D IPG108D IPG108E IPG208D IPG208E IPC115D IPC315D IPC108D IPC108E IPR208D IPR215D IPL500D TF20D DWB-30KIT TF20D IP-FC215CP IP-FC215CT TF20D DWB-315KIT IP-FC315 TF40D DWS-30KIT IP-FC108 USB-ETH-CONV TF40D IP-FC208 USB-ETH-CONV TF20D DWB-30KIT TF20D DWB-315KIT IP-FC315 TF40D DWS-30KIT IP-FC108 USB-ETH-CONV TF40D IP-FC208 USB-ETH-CONV TF20D IP-FC215CP IP-FC215CT TF20D IP-FC500 Without application With rack application With chiller application Without application Black White Black White White Black Black Black Black Black Black Disconnectable Molex Bayonet Screw Disconnectable Screw Disconnectable Screw Bayonet Screw Disconnectable Molex Disconnectable Screw Disconnectable Molex Bayonet Screw Bayonet Screw Screw IPG100 & IPC100 (10 DIN) IPG115D – IPC115D Power supply 24Vac\dc from TF20D Analogue inputs 10 x config (0÷1V - 0÷5V - 0÷10V - 0÷20mA - 4÷20mA - NTC - PTC - DI) Digital inputs 20 x config (Potential free contacts - Opto-insulated) Relay outputs 12 x5A + 3 x 8A Analogue outputs 4 x config (0÷10V - ON\OFF - Not opto-insulated) 2 x config (0÷10V – 4÷20mA - ON\OFF - Non opto-insulated) 2 x PWM (for fan speed modules - Non opto-insulated) Other outputs Remote keyboard (2 VGIPG/C) RS485 MASTER RS485 SLAVE USB ETHERNET CANBus (Dixell Can Protocol, not open) RS232 Config (optional) Other functions Internal RTC Logging memory (80M) BACNet protocol (optional) LON protocol with external device (optional) IPG200 (10 DIN) IPG215D Power supply 24Vac\dc from TF20D Analogue inputs 10 x config (0÷1V - 0÷5V - 0÷10V - 0÷20mA - 4÷20mA - NTC - PTC - DI) Digital inputs 20 x config (Potential free contacts - Opto-insulated) Relay outputs 15 x 5A Analogue outputs 4 x config (0÷10V - ON\OFF - Not opto-insulated) 2 x config (0÷10V – 4÷20mA - ON\OFF - Non opto-insulated) Other outputs Remote keyboard (2 VGIPG) RS485 MASTER RS485 SLAVE USB ETHERNET CANBus (Dixell Can Protocol, not open) RS232 Config (optional) Other functions Internal RTC Logging memory (80M) BACNet protocol (optional) LON protocol with external device (optional) IPG300 & IPC300 (10 DIN) IPG315D – IPC315D Power supply 24Vac\dc from TF20D Analogue inputs 10 x config (0÷1V - 0÷5V - 0÷10V - 0÷20mA - 4÷20mA - NTC - PTC - DI) Digital inputs 20 x config (Potential free contacts - Opto-insulated) Relay outputs 15 x 5A + 5 SSR Analogue outputs 4 x config (0÷10V - ON\OFF - Not opto-insulated) 2 x config (0÷10V – 4÷20mA - ON\OFF - Non opto-insulated) 2 x PWM (for fan speed modules - Non opto-insulated) Other outputs Remote keyboard (2 VGIPG/C) RS485 MASTER RS485 SLAVE USB ETHERNET CANBus (Dixell Can Protocol, not open) RS232 Config (optional) Other functions Internal RTC Logging memory (80M) BACNet protocol (optional) LON protocol with external device (optional) IPG100, IPG200 & IPC100 (4 DIN) IPG108D – IPG108E – IPG208D IPG208E – IPC108D – IPC108E Display Dual with icons on IPG108E, IPG208E, IPC108E Power supply 24Vac\dc from TF40D Analogue inputs 6 x config (0÷1V - 0÷5V - 0÷10V - 0÷20mA - 4÷20mA - NTC - PTC - DI) Digital inputs 11 x config (Potential free contacts - Opto-insulated) Relay outputs 8 x 5A Analogue outputs 4 x config (0÷10V - ON\OFF - Not opto-insulated) Other outputs Remote keyboard (VGIPG/C) RS485 MASTER or LAN RS485 SLAVE USB ETHERNET via USB-ETH-CONV Other functions Internal RTC Logging memory (80M) BACNet protocol (optional) LON protocol with external device (optional) IPL500 IPL500D Power supply 24Vac\dc from TF20D Other outputs Remote keyboard (VGIPG/C) RS485 MASTER or LAN RS485 SLAVE USB CANBus (Dixell Can Protocol, not open) ETHERNET Other functions Internal RTC Logging memory (80M) BACNet protocol (optional) LON protocol with external device (optional) Internal GPRS modem (optional) iPro Main Features ETHERNET 10/100 • • • • • To connect PC and iPro through ISaGRAF workbench you can download and debug the application in your target (iPro) To connect more iPro different applications on differents iPro exchanges variables (Multimaster connection – no polling) To send mail and sms you can program your iPro so it can sends mail/sms on time or on demand Ethernet ModBUS Slave on TCP/IP to download the map parameters through Wizmate To visit your own website iPro Main Features SERIAL BUS • CAN-Bus (NOT CAN OPEN) iPro is MASTER for a network of CAN devices made by Dixell I/O expansion modules – electronic expansion valve drivers • RS485 MASTER iPro is the MASTER for a network of ModBUS RTU devices (Dixell controllers and/or third party devices ModBUS RTU 485). • RS485 SLAVE To connect iPro to XWEB or standard ModBUS Scada iPro reads/writes variables from/to these network iPro Main Features CAN BUS (IPG-IPL series) LAN (IPS-IPL series) Dixell (no CAN open) Dixell (Multi master) (Master-Slave) SWITCH NO NO iPro iPro iPro iPro Dixell controllers ModBUS TCP/IP Expansion Module Expansion Module ModBUS devices Devices Driver(XEV20D) Driver(XEV20D) Number UP TO 100 NODES SWITCH INPUTS UP TO 4 NODES UP TO 4 NODES Speed 9600-19200 bit/sec 100 Mbit 100 Kbit 19200 bit/sec Max distance 1KM 50mt 400mt 100mt ETH CAN LAN BUS Protocol External HW Devices Terminals RS485 (IPG-IPS-IPL series) ETHERNET (IPG-IPL series) ModBUS RTU ModBUS RTU TCP/IP (Master-Slave) (Multi master) BacNet BacNet NO MASTER for master SLAVE for slave iPro Connections ETHERNET RS485 SLAVE CANBUS RS485 MASTER iPro Expansions & Driver iPro Expansion/Driver IPX115/125D IPX215/225D IPX315/325D IPX106D IPX206D IPX306D Discon./Molex TF10D DWEX60-30KIT (CANBUS + LAN) Bayonet/Screw TF10D IP-FCEX60 (CANBUS + LAN) Discon./Screw TF10D DWEX306-30KIT (CANBUS + LAN) Discon./Molex TF20D DWX115-30KIT DWEX70-30KIT (CANBUS + LAN) Bayonet/Screw TF20D IP-FCX215 IP-FCEX70 (CANBUS + LAN) Discon./Screw TF20D DWX315-30KIT/IP-FCX315 DWX325-30KIT/IP-FCX325 (CANBUS + LAN) TF20D ( 1 valve) TF40D (2 valves) DWXEV30 (CANBUS + LAN) Black White Black Black White Black Black 4 DIN 10 DIN Expansion Module XEV20D 4 DIN Driver for valve/s IPX (4 DIN) EXPANSION MODULE IPX106D IPX206D – IPX306D Power supply 24Vac\dc from TF10D 24Vac\dc from TF10D Analogue inputs 7 x config (0÷1V - 0÷5V - 0÷10V - 0÷20mA - 4÷20mA - NTC - PTC - DI) 7 x config (0÷1V - 0÷5V - 0÷10V - 0÷20mA - 4÷20mA - NTC - PTC - DI) Digital inputs 3 x config (Potential free contacts - Optoinsulated) 3 x config (Potential free contacts - Optoinsulated) Relay outputs 6 x 5A 5 x 5A + 1 x 8A or 4 x 5A + 1 x 8A + 1 x SSR Analogue outputs 3 x config (0÷10V - Not opto-insulated) 3 x config (0÷10V - Not opto-insulated) Other outputs CANBus LAN CANBus LAN Other functions Dip switch for address set Dip switch for address set IPX100 (10 DIN) EXPANSION MODULE IPX115D IPX125D Power supply 24Vac\dc from TF20D 24Vac\dc from TF20D Analogue inputs 10 x config (0÷1V - 0÷5V - 0÷10V 0÷20mA - 4÷20mA - NTC - PTC - DI) 10 x config (0÷1V - 0÷5V - 0÷10V 0÷20mA - 4÷20mA - NTC - PTC - DI) Digital inputs 20 x config (Potential free contacts Opto-insulated) 20 x config (Potential free contacts Opto-insulated) Relay outputs 12 x 5A + 3 x 8A 18 x 5A + 3 x 8A + 4 x SSR Analogue outputs 4 x config (0÷10V - Not opto-insulated) 2 x config (0÷10V - 4÷20mA - ON\OFF - Non opto-insulated) 4 x config (0÷10V - Not opto-insulated) 2 x config (0÷10V - 4÷20mA - ON\OFF - Non opto-insulated) Other outputs CANBus LAN CANBus LAN Other functions Dip switch for address set Dip switch for address set IPX200 (10 DIN) EXPANSION MODULE IPX215D IPX225D Power supply 24Vac\dc from TF20D 24Vac\dc from TF20D Analogue inputs 10 x config (0÷1V - 0÷5V - 0÷10V 0÷20mA - 4÷20mA - NTC - PTC - DI) 10 x config (0÷1V - 0÷5V - 0÷10V 0÷20mA - 4÷20mA - NTC - PTC - DI) Digital inputs 20 x config (Potential free contacts Opto-insulated) 20 x config (Potential free contacts Opto-insulated) Relay outputs 15 x 5A 21 x 5A + 4 x SSR Analogue outputs 4 x config (0÷10V - Not opto-insulated) 2 x config (0÷10V - 4÷20mA - ON\OFF - Non opto-insulated) 4 x config (0÷10V - Not opto-insulated) 2 x config (0÷10V - 4÷20mA - ON\OFF - Non opto-insulated) Other outputs CANBus LAN CANBus LAN Other functions Dip switch for address set Dip switch for address set IPX300 (10 DIN) EXPANSION MODULE IPX315D IPX325D Power supply 24Vac\dc from TF20D 24Vac\dc from TF20D Analogue inputs 10 x config (0÷1V - 0÷5V - 0÷10V 0÷20mA - 4÷20mA - NTC - PTC - DI) 10 x config (0÷1V - 0÷5V - 0÷10V 0÷20mA - 4÷20mA - NTC - PTC - DI) Digital inputs 20 x config (Potential free contacts Opto-insulated) 20 x config (Potential free contacts Opto-insulated) Relay outputs 15 x 5A or 10 x 5A + 5 x SSR 21 x 5A + 4 x SSR or 16 x 5A + 9 x SSR Analogue outputs 4 x config (0÷10V - Not opto-insulated) 2 x config (0÷10V - 4÷20mA - ON\OFF - Non opto-insulated) 4 x config (0÷10V - Not opto-insulated) 2 x config (0÷10V - 4÷20mA - ON\OFF - Non opto-insulated) Other outputs CANBus LAN CANBus LAN Other functions Dip switch for address set Dip switch for address set XEV20D ELECTRONIC EXPANSION VALVE MODULE XEV20D Power supply 24Vac\dc from TF20D for 1 valve or from TF40D for 2 valves Probe inputs Pb1 - Pb2 (Pt1000 - NTC - PTC - DI) Pb3 - Pb4 (0÷1V - 0÷5V - 0÷10V - 0÷20mA - 4÷20mA - Pt1000 - NTC - PTC - DI) Valve number Up to 2 Relay outputs 8 x 5A Other outputs CANBus LAN Other functions Dip switch for address set iPro – Expansion Module Connection Example of connection between iPro 10 DIN and expansion modules iPro Connectivity Example of iPro 10 DIN connectivity iPro Connectivity Example of iPro 4 DIN connectivity iPro Connectivity Example of iProLINK connectivity VISOGRAPH • GRAPICH LCD 240x96 pixel • Processor: 32bit • Multi-language • Panel and wall mounting • Industrial and commercial frame • 8 full programmable keys • 3 wires bus • ASCII or UNICODE characters (different part number) • Software updating from USB (through ISaGRAF® application) VISOGRAPH VISOGRAPH User Interface VGIPG VGIPC VGIPR Wall/Panel mounting. Different part number: - for ASCII fonts - for UNICODE fonts Wall/Panel mounting Only for ASCII fonts Wall/Panel mounting Only for ASCII fonts Without application With chiller application With rack application For models IPG108D, IPG108E, IPG208D, IPG208E, IPG115D, IPG215D, IPG315D, IPL500D For models IPC108D, IPC108E IPC115D, IPC315D For models IPR208D, IPR215D VISOTOUCH • Display: 4,3’’ TFT color • Resolution: 480x272 pixel • Portrait and Landscape orientation • Technology: resistive touch • Panel and Wall mounting • Alarm and Power front leds • Temperature and Humidity sensors on board • Processor: 32bit VTIPG For all iPro models • 100% compatible with Visograph connections • Main project upload through USB stick • Minor modifies on code can be uploaded through the iPro VISOTOUCH Dimension Frontal (Panel Mounting) 134x93x4.5 mm Dimension PCB 119x78x1.6 mm Frontal IP (with UR/NTC sensor) IP20 Frontal IP (without UR/NTC sensor Panel mounting) IP54 Rear IP (Panel mounting) IP20 12Vdc (like visopraph 2.0) Power Supply 24Vac 1 on-board NTC (103AT 10kΩ@25°C) 1 remote -10 to 50 C (on-board) Measuring and Regulation Range NTC -50 to 110 C (remote) Umidity probe (UR) 1 on-board Measuring range Umidity 20 to 85% Accuracy Umidity Sensor (SH71) USB connector Buzzer +/-3% (20 to 80%) +/-5% elsewhere Rear (standard A type) yes Operating Temperature -20 to 60 C Storage Temperature -25 to 70 C Relative Humidity 20 to 85% Thank you! Dixell reserves the right to alter its products without notice. All rights reserved. Because environmental conditions are outside of Dixell’s control, we cannot assume liability for results obtained or any damages which may occur due to improper application.