Transcript
BACKGROUND
At that time, category 5 was the emerging standard and the main target was to move from coax-based Ethernet to twisted pairs technology. Project after project, improvement after improvement, we achieved a huge experience in design, products and applications. This know-how has now merged into Rertech, as 20 years of experience are not worth nothing. At Rertech we believe structured wiring’s key factors of success are quality, ease of installation and reliability. We pursue the philosophy of “few products, yet the right ones” following the famous quote by mr. Henry Ford, founder of Ford automobiles, about his best seller “model T”:
”You can have any colour car as you want so long as it’s black”
Rertech Team, 2011
A FEW WORDS TO START
L
ong time ago, it was 1991, we began our operations on structured wiring systems.
3
ABOUT THIS CATALOGUE PRODUCTS
ABOUT THIS CATALOGUE
This catalogue is intended as a “short form” catalogue reporting most relevant products and related part numbers. Most products shown in this catalogue are supported by detailed data sheet which can be requested to our sales staff. PRICING Pricing information is supported by a separate price list document which is constantly maintained to keep track of market trends and of raw material cost fluctuations. Ask our sales staff for the latest update. ORDERING Purchase orders must comply with our general sales terms and conditions, available for download on our web site. GUARANTY Product, individually, are guaranteed against defects in materials and workmanship for a period of 12 months from delivery date. EXTENDED GUARANTY Copper based structured cabling projects, as a whole, can be granted 10 or 25 years extended guaranty. Ask our sales staff for offered terms and conditions. ENVIRONMENT All products listed herein are RoHs compliant.
4
SUMMARY
COPPER BASED SOLUTIONS 6
Cat6-Cat6A UTP terminations
7
Cat6-Cat6A UTP distribution
8
Cat6-Cat6A UTP jumpers
9
Cat6 UTP LAN cables
10
Cat6A UTP LAN cables
11
Shielded solutions
12
Cat6-Cat6A shielded terminations
13
Cat6-Cat6A shielded distribution
14
Cat6-Cat6A shielded jumpers
15
Cat6 shielded LAN cables
16
Cat6A shielded LAN cables
17
FIBRE BASED SOLUTIONS Optical Networks
18
Field installable optical connectors
19
Optical adapters
20
Optical jumpers
21
Optical subscriber outlets
22
Optical distribution sub-racks
23
Metal armoured optical cables
24
Indoor-Outdoor optical cables
25
Air-Blown micro cables
26
FTTH subscriber cables
27
Optical fibre specifications
28
SUMMARY
Unshielded solutions
MISCELLANEA Intelligent Patching Introducing IPS
Accessories
29 30
32
Workstation—Faceplates
33
Voice products
34
Tools
36
5
UNSHIELDED SOLUTIONS
UNSHIELDED SOLUTIONS 6
UNSHIELDED SOLUTIONS
UNSHIELDED RJ45 TERMINATIONS Modular Termination Cat 6/Class E - Unshielded 70-020-001-00 110™ tool operated 22-26 AWG solid conductors
RJ45 TERMINATIONS
568A/B cabling, with cable holding cap Supersedes EIA/TIA 568B.2.1 Black colour
Modular Termination Cat 6A/Class EA- Unshielded 70-020-021-00 110™ tool operated 22-26 AWG solid conductors 568A/B cabling, with cable holding cap Supersedes EIA/TIA 568B.2.10 Black colour
Common Specifications Body: High impact polycarbonate Flammability: V0 (UL94) Contacts: Phosphor bronze -RJ45 side: gold plated -IDC side: tin/nickel plated Conductor re-terminations: > 100
Part Number
Description
Q.ty/pkg
70-020-001-00
Category 6 UTP tool operated termination
24
70-020-021-00
10 GB category 6A UTP tool operated termination
24
7
UNSHIELDED DISTRIBUTION Patch Panel
UNSHIELDED DISTRIBUTION 8
Cat 6/Class E Unshielded 70-010-001-00 24 ports, 1 unit Front sliding and upwards rotating front panel AWG22-26 110™ tool termination Label holder and cable fixing support Supersedes EIA/TIA 568B.2.1 Black colour
Patch Panel Unloaded 24 ports 1U 70-012-100-00 Very compact design, 24 ports in 1 U Fits with any Rertech termination (cat6/cat6A, shielded/unshielded) Integrated and removable label holder Sturdy nickel plated brass counterframe Also available with integrated and removable cable fixing rack (P/N 70012-101-00) Black colour
Part Number
Description
Q.ty/pkg
70-010-001-00
24 ports, UTP category 6, 1U loaded patch panel with sliding feature
1
70-012-100-00
24 ports, 19” 1U unloaded patch panel
1
70-012-101-00
24 ports, 19” 1U unloaded patch panel with cable fixing accessory
1
UNSHIELDED JUMPERING Patch Cords
70-030-001-XY High quality moulded boot AWG24 stranded cable Passes category 6 channel requirements LSZH jacket, grey colour
Patch Cords Cat 6A/Class EA UTP 70-030-021-XY High quality moulded boot AWG24 stranded cable Passes category 6A channel requirements LSZH jacket, grey colour
Category 6 Part Number
Description
Q.ty/pkg
70-030-001-01
U/UTP cat6 jumper, LSZH grey, 1 m
1
70-030-001-02
U/UTP cat6 jumper, LSZH grey, 2 m
1
70-030-001-03
U/UTP cat6 jumper, LSZH grey, 3 m
1
70-030-001-05
U/UTP cat6 jumper, LSZH grey, 5 m
1
Category 6A Part Number
Description
Q.ty/pkg
70-030-021-01
U/UTP cat6A jumper, LSZH grey, 1 m
1
70-030-021-02
U/UTP cat6A jumper, LSZH grey, 2 m
1
70-030-021-03
U/UTP cat6A jumper, LSZH grey, 3 m
1
70-030-021-05
U/UTP cat6A jumper, LSZH grey, 5 m
1
UNSHIELDED JUMPERING
Cat 6/Class E UTP
9
CAT6 UTP CABLES LAN Cable Cat 6/Class E U/UTP 4x2x23AWG 10-110-001-X0 Central cross design
CAT6 UTP CABLES
Supersedes ETA/TIA 568B.2.1 providing large headroom
Construction Conductor
23AWG solid copper
Insulation
PE
Pair separation
Plastic cross
Jacket
PVC or LSZH, grey
Mechanical Bending radius
0-50°C (installing)
Operating temp.
Fire resistance
RoHS
F
RL
IL
MHz
dB
dB/100m
-20+60°C (operating)
Safety
NEXT
PSNEXT
ELFEXT
PSELFEXT
dB
dB
dB/100m
dB/100m
1
20.0
2.0
74.3
72.3
67.8
64.8
IEC 60332-1
4
23.0
3.8
65.3
63.3
55.8
52.8
NF C 32-070 2.1
10
25
6.0
59.3
57.3
47.8
44.8
IEC 60754-1
16
25
7.6
56.2
54.2
43.7
40.7
IEC 60754-2
20
25
8.52
54.8
52.8
41.8
38.8
IEC 61034
31.25
23.6
10.7
51.9
49.9
37.9
34.9
2002/95/EC
62.5
21.5
15.5
47.4
45.4
31.9
28.9
100
20.1
19.9
44.3
42.3
27.8
24.8
Transmission standards
125
19.4
22.5
42.8
40.8
25.9
22.9
ISI/IEC 11801 CLASS E
200
18.0
29.1
39.8
37.8
21.8
18.8
En 50173
250
17.3
33.0
38.3
36.3
19.8
16.8
EIA/TIA 568B.2.1
Part Number
10
≥ 50 mm (installing)
Description
Q.ty/pkg
10-110-001-00
4x2x23AWG category 6 U/UTP cable, grey PVC jacket
Box 305 mtr
10-110-001-10
4x2x23AWG category 6 U/UTP cable, grey LSZH jacket
Box 305 mtr
CAT6A UTP CABLES LAN Cable Cat 6A/Class EA U/UTP 4x2x23AWG 10-110-021-X0 Supersedes ETA/TIA 568B.2.10 providing large headroom
Construction Conductor
23AWG solid copper
Insulation
PE
Pair separation
Plastic cross
Jacket
PVC or LSZH, grey F
RL
IL
NEXT
PSNEXT
ELFEXT
PSELFEXT
MHz
dB
dB/100m
dB
dB
dB/100m
dB/100m
Mechanical Bending radius
≥ 50 mm (installing)
Operating temp.
1
20.0
2.0
77
75
71
68
0-50°C (installing)
4
23.0
3.8
68
66
59
56
-20+60°C (operating)
10
25
6.0
62
60
51
48
16
25
7.6
59
57
47
44
20
25
8.5
58
56
45
42
Safety IEC 60332-1
31.25
23.6
10.7
55
53
41
38
NF C 32-070 2.1
62.5
21.5
15.4
50
48
35
32
IEC 60754-1
100
20.1
19.8
47
45
31
28
IEC 60754-2
200
18.0
29.1
43
41
25
22
IEC 61034
250
17.3
32.8
41
39
23
20
2002/95/EC
300
17.8
36.4
40
38
21
18
350
16.3
39.8
39
37
20
17
400
15.9
43
38
36
19
16
ISI/IEC 11801 CLASS EA
450
15.5
46
38
36
18
15
En 50173
500
15.2
48.9
37
35
17
14
Fire resistance
RoHS
Transmission standards EIA/TIA 568B.2.10
Part Number
Description
CAT6A UTP CABLES
Central cross design
Q.ty/pkg
10-110-021-00
4x2x23AWG category 6A U/UTP cable, grey PVC jacket
Box 305 mtr
70-110-021-10
4x2x23AWG category 6A U/UTP cable, grey LSZH jacket
Box 305 mtr
11
SHIELDED SOLUTIONS
SHIELDED SHIELDED SOLUTIONS 12
SOLUTIONS
SHIELDED TERMINATIONS Modular Termination Cat 6/Class E - Shielded Easy tooless operation Cast alloy robust construction 22-26 AWG solid conductors 568A/B cabling Supersedes EIA/TIA 568B.2.1
10G Modular Termination Cat 6A/Class EA - Shielded 70-021-021-00 Easy tooless operation Cast alloy robust construction 22-26 AWG solid conductors 568A/B cabling Supersedes EIA/TIA 568B.2.10
Common Specifications Plastic parts: High impact polycarbonate Metal body: Moulded cast alloy Flammability: V0 (UL94) Contacts: Phosphor bronze -RJ45 side: gold plated -IDC side: tin/nickel plated Conductor re-terminations: > 100
Part Number
Description
RJ45 TERMINATIONS
70-021-001-00
Q.ty/pkg
70-021-001-00
Category 6 tooless shielded termination
24
70-021-021-00
10G Category 6A tooless shielded termination
24
13
SHIELDED DISTRIBUTION Patch Panel Unloaded 24 ports 1U
SHIELDED DISTRIBUTION 14
70-010-101-00 Very compact design, 24 ports in 1U Fits with any Rertech termination (cat6/cat6A, UTP and shielded) Integrated and removable label holder Sturdy nickel plated brass counterframe Integrated and removable cable fixing rack Black colour
Part Number
Description
70-012-101-00
24 ports, 19” 1U unloaded patch panel with cable fixing rack
Q.ty/pkg 1
SHIELDED JUMPERING Patch Cords Cat 6/Class E Shielded High quality moulded boot AWG24 stranded cable LSZH jacket Individual packing
Patch Cords Cat 6A/Class EA Shielded 70-031-021-XY High quality moulded boot AWG24 stranded cable LSZH jacket Individual packing
Category 6 Part Number
Description
Q.ty/pkg
70-031-001-01
Shielded cat6 jumper, LSZH grey, 1 m
1
70-031-001-02
Shielded cat6 jumper, LSZH grey, 2 m
1
70-031-001-03
Shielded cat6 jumper, LSZH grey, 3 m
1
70-031-001-05
Shielded cat6 jumper, LSZH grey, 5m
1
Category 6A Part Number
Description
Q.ty/pkg
70-031-021-01
Shielded cat6A jumper, LSZH grey, 1 m
1
70-031-021-02
Shielded cat6A jumper, LSZH grey, 2 m
1
70-031-021-03
Shielded cat6A jumper, LSZH grey, 3 m
1
70-031-021-05
Shielded cat6A jumper, LSZH grey, 5 m
1
SHIELDED PATCHCORDS
70-031-001-XY
15
CAT6 SHIELDED CABLE LAN Cable Cat 6/Class E F/UTP 4x2x23AWG
CAT6 SHIELDED CABLE
10-111-001-30
Construction Conductor
23AWG solid copper
Insulation
PE
Pair separation
Plastic cross
Screening
Al foil
Jacket
LSZH, grey
Mechanical
≥ 25 mm (operating) 0-50°C (installing)
Operating temp.
-20+60°C (operating)
Safety
Fire resistance
RoHS
EIA/TIA 568B.2.1 ISI/IEC 11801 CLASS E En 50173
10-111-001-30
F
RL
IL
MHz
dB
dB/100m
NEXT
PSNEXT
ELFEXT
PSELFEXT
dB
dB
dB/100m
dB/100m
1
20.0
2.0
74.3
72.3
67.8
64.8
IEC 60332-1
4
23.0
3.8
65.3
63.3
55.8
52.8
NF C 32-070 2.1
10
25
6.0
59.3
57.3
47.8
44.8
IEC 60754-1
16
25
7.6
56.2
54.2
43.7
40.7
IEC 60754-2
20
25
8.52
54.8
52.8
41.8
38.8
IEC 61034
31.25
23.6
10.7
51.9
49.9
37.9
34.9
2002/95/EC
62.5
21.5
15.5
47.4
45.4
31.9
28.9
100
20.1
19.9
44.3
42.3
27.8
24.8
125
19.4
22.5
42.8
40.8
25.9
22.9
200
18.0
29.1
39.8
37.8
21.8
18.8
250
17.3
33.0
38.3
36.3
19.8
16.8
Transmission standards
Part Number
16
≥ 50 mm (installing)
Bending radius
Description 4x2x23AWG category 6 F/UTP cable, grey LSZH jacket
PVC jacket and 305m box packing available on request
Q.ty/pkg Reel 500 mtr
CAT6A SHIELDED CABLE LAN Cable Cat 6A/Class EA F/UTP 10-111-021-30
Construction Conductor
23AWG solid copper
Insulation
PE
Pair separation
Plastic cross
Screening
Al foil
Jacket
LSZH, grey
Mechanical ≥ 50 mm (installing)
Bending radius
≥ 25 mm (operating)
Operating temp.
F
RL
IL
NEXT
PSNEXT
ELFEXT
PSELFEXT
MHz
dB
dB/100m
dB
dB
dB/100m
dB/100m
0-50°C (installing)
1
20.0
2.0
77
75
71
68
-20+60°C (operating)
4
Safety
23.0
3.8
68
66
59
56
10
25
6.0
62
60
51
48
16
25
7.6
59
57
47
44
20
25
8.5
58
56
45
42
IEC 60332-1
31.25
23.6
10.7
55
53
41
38
NF C 32-070 2.1
62.5
21.5
15.4
50
48
35
32
IEC 60754-1
100
20.1
19.8
47
45
31
28
IEC 60754-2
200
18.0
29.1
43
41
25
22
IEC 61034
250
17.3
32.8
41
39
23
20
2002/95/EC
300
17.8
36.4
40
38
21
18
350
16.3
39.8
39
37
20
17
400
15.9
43
38
36
19
16
ISI/IEC 11801 CLASS EA
450
15.5
46
38
36
18
15
En 50173
500
15.2
48.9
37
35
17
14
Fire resistance
RoHS
Transmission standards EIA/TIA 568B.2.10
Part Number 10-111-021-30
Description 4x2x23AWG category 6A F/UTP cable, grey LSZH jacket
PVC jacket and 305m box packing available on request
CAT6A SHIELDED CABLE
4x2x23AWG
Q.ty/pkg Reel 500 mtr
17
OPTICAL FIBRE SOLUTIONS
OPTICAL OPTICAL NETWORKS 18
NETWORKS
FIELD INSTALLABLE CONNECTORS
Field Installable, no epoxy or fusion splicer needed 50-001-XYZ-DD EIA/TIA 604 compliant Factory polished connectors with integrated V-grove mechanical splice Convenient fibre termination in minutes. Few simple tools required (optical cable stripper and fibre cleaver, see tools section in this catalogue) Insertion loss: ≤0.3 dB (0.4 dB max) Return loss: ≤ - 50 dB Endurance: 500 reconnections (< 0.3dB) Available in SC and LC versions, SM and MM, for 2.0 and 0.9 mm cable dia. APC single mode versions available on request
Part Number
Description
Q.ty/pkg
50-001-020-20
SC/PC Multimode field installable connector, 2 mm boot
1
50-001-040-20
LC/PC Multimode field installable connector, 2 mm boot
1
50-001-120-20
SC/PC Single mode field installable connector, 2 mm boot
1
50-001-120-09
SC/PC Single mode field installable connector, 0.9 mm boot
1
50-001-140-20
LC/PC Single mode field installable connector, 2 mm boot
1
50-001-140-09
LC/PC Single mode field installable
1
PRE-POLISHED CONNECTORS
Optical Connectors
19
OPTICAL ADAPTERS ST/ST MM Optical Adapter 50-000-010-00 EIA/TIA 604 compliant Phosphor bronze sleeve Insertion loss: < 0.3 dB Durability: <0.2 dB (1000 mates)
OPTICAL ADAPTERS 20
SC/SC Optical Adapter 50-000-X2Z-00 EIA/TIA 604 compliant Zirconia or phosphor bronze sleeve Insertion loss: < 0.3 dB Durability: <0.2 dB (1000 mates)
ST Optical Adapter 50-000-X4Z-00 EIA/TIA 604 compliant Zirconia or phosphor bronze sleeve Insertion loss: < 0.3 dB Durability: <0.2 dB (1000 mates)
Part Number
Description
Q.ty/pkg
50-000-010-00
ST/PC multimode adapter
24
50-000-020-00
SC/PC multimode adapter, beige
24
50-000-021-00
SC/PC duplex multimode adapter, beige
12
50-000-040-00
LC/PC multimode adapter, beige
24
50-000-041-00
LC/PC duplex multimode adapter, beige
12
50-000-120-00
SC/PC single mode adapter, blue
24
50-000-121-00
SC/PC duplex single mode adapter, blue
12
50-000-140-00
LC/PC single mode adapter, blue
24
50-000-141-00
LC/PC duplex single mode adapter, blue
12
Additional adapter types available on request (APC versions, FC, MTRJ, hybrid etc…)
OPTICAL JUMPERS Optical Jumpers EIA/TIA 604 compliant Available with ST/SC/FC and LC connectors, simplex and duplex SMR, OM1, OM2 and OM3 cables, 0.9, 2.0 and 3.0 mm cable diameter Insertion loss ≤ 0.3 dB, return loss ≤ -40 dB (-60 dB for APC type) Durability: 500 mates, <0.2 dB
0: none 1: ST
2: SC
3: FC 5: SC
4: LC APC
6: LC
Length in meters
APC
-H: half meter Side A connector 1: ST
2: SC
3: FC 5: SC
5
0: SIMPLEX
4: LC APC
6: LC
1
example
Connector type
1: DUPLEX APC
—
C1
C2
T
—
F
0
C
3 meters
5H:
5.5 meters
84:
84 meters
L
—
Fibre type
L
Fibre type
0: SMR
1: OM1
0: 0.9 mm tight
2: OM2
3: OM3
1: 2 mm blue 2: 3 mm yellow
Most popular codings Part Number
03:
Description
Q.ty/pkg
51-111-202-01
ST/ST jumper, duplex, OM2 3mm, 1m
1
51-111-202-03
SC/SC jumper, duplex, OM2 3mm, 3m
1
51-221-202-01
SC/SC jumper, duplex, OM2 3mm, 1m
1
51-221-202-03
SC/SC jumper, duplex, OM2 3mm, 3m
1
51-441-202-01
LC/LC jumper, duplex, OM2 3mm, 1m
1
51-441-202-03
LC/LC jumper, duplex, OM2 3mm, 3m
1
51-200-000-02
SC pigtail, simplex, SMR 0.9, 2m
1
51-220-001-02
SC/SC jumper, simplex, SMR 2mm, 2m
1
51-400-000-02
LC pigtail, simplex, SMR 0.9 mm, 2m
1
51-440-001-02
LC/LC jumper, simplex, SMR 2mm, 2m
1
OPTICAL JUMPERS
CODING CHART
Side A connector
21
OPTICAL SUBSCRIBER OUTLETS Optical outlet 2 fibres, termination only 70-095-003-00 Compact and nice looking Suitable for field installable connectors Rear side cable entry
OPTICAL OUTLETS
Suitable for SC or LC adapters PC-ABS construction Dimension 86x86x23 (mm WxHxD)
Optical outlet 4 fibres, splice & termination 70-095-001-00 Ergonomic, small and compact design Splicing, storage and termination functions Accurate fibre management (30 mm radius) Rear or bottom cable entry Suitable for SC or LC adapters High impact polystyrene construction Dimension 180 x 80 x 20 (mm, WxHxD)
Part Number
22
Description
Q.ty/pkg
70-095-003-00
Compact optical outlet, 2 fibres, 86x86 mm
1
70-095-001-00
Splice and termination optical outlet, up to 4 fibres
1
OPTICAL DISTRIBUTORS 19” Optical sub-rack 24 ports, swinging design
Scope of Delivery Optical subrack: Splicing cassettes: Subrack cover: Fibre tubes, 2 mtrs long: Screw/nut pairs: Fibre circulators: Laser warning labels: Installation instructions:
Part Number
1 4 1 2 4 4 3 1
1 unit, 19” rack mount Compact optical subrack for telecommunication or networking applications. Can handle 24 splices/terminations (SC, ST or LC adapters) or 48 splices/ terminations (LC duplex) Swinging design (opening left to right) simplifies cabling and access while avoiding cable/fibre stress and protecting eyes from laser light Left hand side cable entry (from top or bottom), up to 2 cables Right hand side patchcords routing 4 splicing cassettes, each handling up to 12 splices, can be individually accessed thanks to their hinged mechanism Compact splicing cassettes feature fibre storage and “8” figure (inversion of direction) Steel construction, powder painted, grey (RAL7035)
Description
Q.ty/pkg
50-010-010-00
24 ports, 19” 1U optical splice/ termination subrack, ST/FC type
1
50-010-020-00
24 ports, 19” 1U optical splice and termination subrack, SC/LC type
1
50-010-021-00
24 ports, 19” 1U optical splice and termination subrack, SC duplex type
1
OPTICAL DISTRIBUTORS
50-010-0XY-00
23
OPTICAL CABLES METAL ARMOURED Outdoor, metal armoured, 8-24 cores 20-101-XYZ-00
METAL ARMOURED CABLE 24
Mono-loose tube construction Corrugated steel tape + glass yarns armouring High tensile strength: 2000 N (installation) High crush resistance: 3000 N/10 cm Rodent proof 8.3 mm outside diameter (9.4 mm for 24 cores versions)
HDPE outer jacket Corrugated steel tape Optical cores Filling jelly Fibergalss yarns Loose tube
Part Number
Description
Q.ty/pkg
20-101-008-00
8 cores, G652D LWP, PE jacket
2,000 mtr
20-101-012-00
12 cores, G652D LWP, PE jacket
2,000 mtr
20-101-024-00
24 cores, G652D LWP, PE jacket
2,000 mtr
20-101-108-00
8 cores, OM1 62.5/125, PE jacket
2,000 mtr
20-101-112-00
12 cores, OM1 62.5/125, PE jacket
2,000 mtr
20-101-124-00
24 cores, OM1 62.5/125, LSZH jacket
2,000 mtr
20-101-208-00
8 cores, OM2 50/125, LSZH jacket
2,000 mtr
20-101-212-00
12 cores, OM2 50/125, LSZH jacket
2,000 mtr
20-101-224-00
24 cores, OM2 50/125, LSZH jacket
2,000 mtr
20-101-308-00
8 cores, OM3 50/125, LSZH jacket
2,000 mtr
20-101-312-00
12 cores, OM3 50/125, LSZH jacket
2,000 mtr
20-101-324-00
24 cores, OM3 50/125, LSZH jacket
2,000 mtr
INDOOR-OUTDOOR CABLES Indoor/Outdoor, general purpose, 4-12 cores
Mono-loose tube construction Fully dielectric High tensile strength: 1500 N (installation) Suitable for indoor and outdoor installation 7 mm outside diameter
Halogen free Jacket
Optical cores Loose tube
Part Number
Description
Q.ty/pkg
20-001-004-00
4 cores, G652D LWP, LSZH jacket
2,000 mtr
20-001-008-00
8 cores, G652D LWP, LSZH jacket
2,000 mtr
20-001-012-00
12 cores, G652D LWP, LSZH jacket
2,000 mtr
20-001-104-00
4 cores, OM1 62.5/125, LSZH jacket
2,000 mtr
20-001-108-00
8 cores, OM1 62.5/125, LSZH jacket
2,000 mtr
20-001-112-00
12 cores, OM1 62.5/125, LSZH jacket
2,000 mtr
20-001-204-00
4 cores, OM2 50/125, LSZH jacket
2,000 mtr
20-001-208-00
8 cores, OM2 50/125, LSZH jacket
2,000 mtr
20-001-212-00
12 cores, OM2 50/125, LSZH jacket
2,000 mtr
20-001-304-00
4 cores, OM3 50/125, LSZH jacket
2,000 mtr
20-001-308-00
8 cores, OM3 50/125, LSZH jacket
2,000 mtr
20-001-312-00
12 cores, OM3 50/125, LSZH jacket
2,000 mtr
INDOOR-OUTDOOR CABLES
20-001-XYZ-00
25
AIR-BLOWN MICRO CABLES Air blown micro cable, 12 to 144 cores 20-020-XYZ-00
AIR-BLOWN MICRO CABLES 26
Micro loose tubes construction Central FRP strength member Water-blocking yarns to prevent moisture Low friction PE jacket 1000 N tensile strength, lightweight construction
12-14-48-72 cores
96 cores
12 cores
24 cores
48 cores
144 cores
72 cores
96 cores
144 cores
Cores/tube
12
12
12
12
12
12
Tubes/Fillers
1/5
2/4
4/2
6/0
8/0
12/0
Weight(kg/km)
28
28
28
28
42
55
O.D (mm)
5.9
5.9
4.9
5.9
6.9
8.7
Part Number
Description
Q.ty/pkg
20-020-012-00
12 cores, G652D LWP, PE jacket
4,000 mtr
20-020-024-00
24 cores, G652D LWP, PE jacket
4,000 mtr
20-020-048-00
48 cores, G652D LWP, PE jacket
4,000 mtr
20-020-072-00
72 cores, G652D LWP, PE jacket
4,000 mtr
20-020-096-00
96 cores, G652D LWP, PE jacket
4,000 mtr
20-020-044-00
144 cores, G652D LWP, PE jacket
4,000 mtr
OPTICAL FTTH CABLES ARP (Aramid Reinforced Plastics or steel wire rods (x2)
FTTH Subscriber Cable 20-091-XYZ-00
Low friction LSZH jacket
Stee l wire s
FTTH drop cable 20-092-012-00 Metal armoured, self suspending, outdoor use 2 cores, G652D fibre 2.0 x 5.0 mm cross section 600 N tensile strength (installing) Easy stripping Black PE jacket
Optical Core(s)
PE jacke t
Part Number
Description
Q.ty/pkg
20-091-011-00
1 x G652D, metal, subscriber cable
2000 mtr
20-091-611-00
1 x G657A, metal, subscriber cable
2000 mtr
20-091-012-00
2 x G652D, metal, subscriber cable
2000 mtr
20-091-612-00
2 x G657A, metal, subscriber cable
2000 mtr
20-091-001-00
1 x G652D, dielectric, subscriber cable
2000 mtr
20-091-601-00
1 x G657A, dielectric, subscriber cable
2000 mtr
20-091-002-00
2 x G652D, dielectric, subscriber cable
2000 mtr
20-091-602-00
2 x G657A, dielectric, subscriber cable
2000 mtr
20-092-012-00
2 x G652D, metal, drop cable, PE
2000 mtr
FTTH CABLES
Optical core(s)
Dielectric or metal armoured 1 or 2 cores, G652D or G657A (bending insensitive) Small design (mm 1.6 x 2.0), easy installation 100 N tensile strength (installing) Easy stripping Low friction, white LSZH jacket
27
OPTICAL FIBRE SPECIFICATIONS SINGLE MODE
FIBRE SPECIFICATIONS 28
Characteristics
Unit
Attenuation
@1310 nm
dB/km
Attenuation
@ 1550 nm
dB/km
G652D ≤0.38 Max (≤0.35 avg) ≤0.25 Max (≤0.22 avg)
G657A ≤0.34
≤0.20
Chromatic dispersion 1285-1330 nm
ps/nm.km
≤3.5
≤3.5
Chromatic dispersion 1550 nm
ps/nm.km
≤18.0
≤18.0
1300 to 1324
1304 to 1322
≤0.092
≤0.090
ps/√km
≤0.20
≤0.20
Cabled cut-off wavelength
nm
≤1320
≤1260
Mode field diameter @ 1310 nm
µm
9.3±0.5
9.1±0.4
Core-clad concentricity error
µm
≤0.8
≤0.5
Cladding non circularity
%
≤1.0
≤0.8
Cladding diameter
µm
125 ± 1.0
125 ± 0.7
Coating diameter
µm
245 ± 10
245 ± 5
Zero dispersion wavelength
nm
Zero dispersion slope
ps/nm2.km
Polarization mode dispersion
MULTI MODE Characteristics
Unit
Attenuation
@1310 nm
dB/km
≤3.0
≤3.0
≤3.0
Attenuation
@ 1550 nm
dB/km
≤1.0
≤1.0
≤1.0
Bandwidth
@ 850 nm
MHz.km
≥200
≥500
≥1500
Bandwidth
@ 1300 nm
MHz.km
≥500
≥500
≥500
Numeric aperture
OM1
OM2
OM3
0.200±0.015 0.200±0.015 0.200±0.015
Core diameter
µm
50 ± 2.0
50 ± 2.0
50 ± 2.0
Core non circularity
%
≤2
≤2
≤2
Cladding diameter
µm
125 ± 2.0
125 ± 2.0
125 ± 2.0
Cladding non circularity
%
≤2.0
≤2.0
≤2.0
Core concentricity error
µm
≤6
≤6
≤6
Coating diameter
µm
245 ± 10
245 ± 10
245 ± 10
IPS INTELLIGENT PATCHING
PATCHING SOLUTIONS
INTELLIGENT PATCHING
INTELLIGENT
29
INTRODUCING IPS
I INTELLIGENT PATCHING 30
ntelligent patching systems are a combination of both hardware parts and software code providing the IT staff advanced network configuration capabilities. This job can be accomplished with various technical solutions at different sophistication levels. With IPS, we pursued the highest level of sophistication by providing a dramatically simple, yet effective, solution. IPS will save up to 30% of patching time and provide virtually zero mis-patching. IPS is based on its unique patch panels driven by the network management software, available for both category 6 unshielded and shielded networks. No specific patch cords are requested. IPS panels are characterised by multi colour LEDs on each port, and by a micro-switch sensing if the related patch cord is plugged or unplugged. Each group of patch panels (up to 16) is driven by a master patch panel which connects to the management console. IPS panels within the same group must be at a maximum distance of 2 meters. More groups of patch panels can be interconnected in a bus configuration, within a maximum distance of 1000 mtrs.
IPS’s network management software intelligently handles the full network configuration: A) at the initial stage, by supporting the IT staff to set up and simulate the patching configuration; B) during the patching operation, by guiding the IT staff to cross -connect patch cords by means of clear LED indications; and, C) during standard operation, by detecting and locating unauthorized or activity and generating alert messages. Phase (B) specifically is of great support to IT staff; patching phase is guided on a step by step basis by IPS management software, as LEDs related to ports to be patched are blinking until successful patching is made.
24 ports, 1 unit
IPS Patch Panel
Preloaded with cat6 UTP terminations
24 ports, Category 6 UTP
Works as master or slave
70-890-000-00
Inclusive of LED indicators Runs on windows™ XP™, VISTA™ or Windows™ 7
IPS management software Single user licence 70-890-100-00
Part Number
Description
Q.ty/pkg
70-890-000-00
24 ports, 1 unit, category 6 UTP preloaded IPS panel.
1
70-890-100-00
IPS management software individual licence
1
INTELLIGENT PATCHING
INTRODUCING IPS
31
ACCESSORIES
ACCESSORIES
ACCESSORIES 32
WORKSTATION Workstation faceplate 86 x 86 70-090-00X-00 Back Box 86x86
WORKSTATION
70-090-999-00 Modular adapter 22.5x45 and 45x45 70-091-00X-00 Faceplate frame 80x80 (45x45 adapters) 70-091-100-00 Back Box 80x80 70-091-999-00 Part Number
Description
Q.ty/pkg
70-090-001-00
1 port 86x86 faceplate with shutter
1
70-090-002-00
2 ports 86x86 faceplate with shutter
1
70-091-001-00
22.5x45 mm adapter with shutter
1
70-091-002-00
45x45 mm adapter with shutter
1
70-091-100-00
80x80 frame (internal 45x45)
1
70-090-999-00
86x86 surface mount back box
1
70-091-999-00
80x80 surface mount back box
1
33
VOICE PRODUCTS Modular termination Category 3 UTP termination 70-020-000-00 6p6c RJ11 modular jack Tooless termination, 23-24AWG White colour
VOICE PRODUCTS
Voice Patch Panel 50 ports cat3 patch panel 70-010-111-00 19”, 1 Unit, robust construction 110™ tool operated termination
10 pair voice connector Disconnection module 30-010-011-00 Superior quality PBT construction Category 5 performance 1.5µm silver plated terminals Can also mount on vertical rods with included earthing clips—also providing grounding facility for easy installation of surge protections
Part Number
34
Description
70-020-000-00
Category 3 UTP termination, RJ11 6p6c, tooless, white
70-010-111-00
50 ports, Category 3 , 19” 1U patch panel
30-010-011-00
10 pair disconnection module, 1-0 numbering, with clips
Q.ty/pkg 10 1 10
VOICE CABLE PLUGS Multi pair cable Category 3 UTP multi-pair cable 70-120-XXX-00 24AWG solid copper conductors LSZH grey jacket
Crimp type RJ45 Plug Category 6 unshielded 70-030-999-00 8p8c plug Gold plated contacts
Crimp type RJ45 Plug Category 6 shielded 70-031-999-00 8p8c plug Gold plated contacts
Part Number
Description
Q.ty/pkg
10-120-025-00
25x2x24AWG category 3 cable, LSZH grey jacket, indoor
500
10-120-050-00
50x2x24AWG category 3 cable, LSZH grey jacket, indoor
500
10-120-100-00
100x2x24AWG category 3 cable, LSZH grey jacket, indoor
VOICE CABLE - PLUGS
Available in 25, 50 and 100 pairs
500
70-030-999-00
RJ45 8p8c category 6 unshielded crimp-type plug
100
70-031-999-00
RJ45 8p8c category 6 shielded crimp type plug
100
35
TOOLS
Insertion Tool LSA-PLUS™ type 70-900-001-00
Insertion Tool 110™ type 70-900-002-00
TOOLS
Crimping tool Works on RJ11 and RJ45 plugs 70-900-003-00
Optical cable stripper Strips different cable diameters 70-900-004-00 Strips outer jacket from 2.0-2.4 mm, 2.8-3.0 mm and 2.0-3.0 loose tube fiber Strips 900um buffer from loose buffer without removing acrylate Strips buffer and acrylate from 900/125µm and 250/125µm fiber
Part Number
36
Description
Q.ty/pkg
70-900-001-00
LSA-PLUS™ insertion tool
1
70-900-002-00
110™ insertion tool
1
70-900-003-00
Plug crimping tool
1
70-900-004-00
Universal optical cable stripper
1
TOOLS
Installer’s toolkit 70-900-010-00 “must have” basic tools housed in a sturdy and robust portable case. Includes: RJ11 and RJ45 crimp tool Soldering iron 110™ and LSA-PLUS™ insertion tools Cable stripper Network tester
...and more
Fibre Cleaver 70-900-015-00 Reliable and lightweight precision fibre cleaver
TOOLS
Pliers and screwdrivers set
Precisely cuts multimode and singlemode 125 µm bare fibres with 250 or 900 µm outer coating Cutting angle: 90° ±0.5°, length 5-30 mm Up to 20,000 quality cleaves using the same blade
Part Number
Description
Q.ty/pkg
70-900-010-00
Installer’s toolkit
1
70-900-015-00
Precision fibre cleaver
1
37
Italy Office Phone +39 011 728422
[email protected]
Middle East Office Phone +971 4 4230877
[email protected]
www.rertech.it Product information and specifications reported in this document are deemed to be accurate on the date of publication as far as product comparison and ordering information are concerned. However, accuracy and completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. The user assumes all risks and liabilities in connection with the use of a product or its applications. Rertech reserves the right to change at any time and without notice design, specifications, function, fit or form of its products described herein, including withdrawal at any time of a product offered for sale herein. Rertech and Rertech logo are registered trademarks. Unauthorized use of such registered trademarks is illegal and will be prosecuted