Preview only show first 10 pages with watermark. For full document please download

Ips - Rertech

   EMBED


Share

Transcript

BACKGROUND At that time, category 5 was the emerging standard and the main target was to move from coax-based Ethernet to twisted pairs technology. Project after project, improvement after improvement, we achieved a huge experience in design, products and applications. This know-how has now merged into Rertech, as 20 years of experience are not worth nothing. At Rertech we believe structured wiring’s key factors of success are quality, ease of installation and reliability. We pursue the philosophy of “few products, yet the right ones” following the famous quote by mr. Henry Ford, founder of Ford automobiles, about his best seller “model T”: ”You can have any colour car as you want so long as it’s black” Rertech Team, 2011 A FEW WORDS TO START L ong time ago, it was 1991, we began our operations on structured wiring systems. 3 ABOUT THIS CATALOGUE PRODUCTS ABOUT THIS CATALOGUE This catalogue is intended as a “short form” catalogue reporting most relevant products and related part numbers. Most products shown in this catalogue are supported by detailed data sheet which can be requested to our sales staff. PRICING Pricing information is supported by a separate price list document which is constantly maintained to keep track of market trends and of raw material cost fluctuations. Ask our sales staff for the latest update. ORDERING Purchase orders must comply with our general sales terms and conditions, available for download on our web site. GUARANTY Product, individually, are guaranteed against defects in materials and workmanship for a period of 12 months from delivery date. EXTENDED GUARANTY Copper based structured cabling projects, as a whole, can be granted 10 or 25 years extended guaranty. Ask our sales staff for offered terms and conditions. ENVIRONMENT All products listed herein are RoHs compliant. 4 SUMMARY COPPER BASED SOLUTIONS 6 Cat6-Cat6A UTP terminations 7 Cat6-Cat6A UTP distribution 8 Cat6-Cat6A UTP jumpers 9 Cat6 UTP LAN cables 10 Cat6A UTP LAN cables 11 Shielded solutions 12 Cat6-Cat6A shielded terminations 13 Cat6-Cat6A shielded distribution 14 Cat6-Cat6A shielded jumpers 15 Cat6 shielded LAN cables 16 Cat6A shielded LAN cables 17 FIBRE BASED SOLUTIONS Optical Networks 18 Field installable optical connectors 19 Optical adapters 20 Optical jumpers 21 Optical subscriber outlets 22 Optical distribution sub-racks 23 Metal armoured optical cables 24 Indoor-Outdoor optical cables 25 Air-Blown micro cables 26 FTTH subscriber cables 27 Optical fibre specifications 28 SUMMARY Unshielded solutions MISCELLANEA Intelligent Patching Introducing IPS Accessories 29 30 32 Workstation—Faceplates 33 Voice products 34 Tools 36 5 UNSHIELDED SOLUTIONS UNSHIELDED SOLUTIONS 6 UNSHIELDED SOLUTIONS UNSHIELDED RJ45 TERMINATIONS Modular Termination Cat 6/Class E - Unshielded 70-020-001-00 110™ tool operated 22-26 AWG solid conductors RJ45 TERMINATIONS 568A/B cabling, with cable holding cap Supersedes EIA/TIA 568B.2.1 Black colour Modular Termination Cat 6A/Class EA- Unshielded 70-020-021-00 110™ tool operated 22-26 AWG solid conductors 568A/B cabling, with cable holding cap Supersedes EIA/TIA 568B.2.10 Black colour Common Specifications Body: High impact polycarbonate Flammability: V0 (UL94) Contacts: Phosphor bronze -RJ45 side: gold plated -IDC side: tin/nickel plated Conductor re-terminations: > 100 Part Number Description Q.ty/pkg 70-020-001-00 Category 6 UTP tool operated termination 24 70-020-021-00 10 GB category 6A UTP tool operated termination 24 7 UNSHIELDED DISTRIBUTION Patch Panel UNSHIELDED DISTRIBUTION 8 Cat 6/Class E Unshielded 70-010-001-00 24 ports, 1 unit Front sliding and upwards rotating front panel AWG22-26 110™ tool termination Label holder and cable fixing support Supersedes EIA/TIA 568B.2.1 Black colour Patch Panel Unloaded 24 ports 1U 70-012-100-00 Very compact design, 24 ports in 1 U Fits with any Rertech termination (cat6/cat6A, shielded/unshielded) Integrated and removable label holder Sturdy nickel plated brass counterframe Also available with integrated and removable cable fixing rack (P/N 70012-101-00) Black colour Part Number Description Q.ty/pkg 70-010-001-00 24 ports, UTP category 6, 1U loaded patch panel with sliding feature 1 70-012-100-00 24 ports, 19” 1U unloaded patch panel 1 70-012-101-00 24 ports, 19” 1U unloaded patch panel with cable fixing accessory 1 UNSHIELDED JUMPERING Patch Cords 70-030-001-XY High quality moulded boot AWG24 stranded cable Passes category 6 channel requirements LSZH jacket, grey colour Patch Cords Cat 6A/Class EA UTP 70-030-021-XY High quality moulded boot AWG24 stranded cable Passes category 6A channel requirements LSZH jacket, grey colour Category 6 Part Number Description Q.ty/pkg 70-030-001-01 U/UTP cat6 jumper, LSZH grey, 1 m 1 70-030-001-02 U/UTP cat6 jumper, LSZH grey, 2 m 1 70-030-001-03 U/UTP cat6 jumper, LSZH grey, 3 m 1 70-030-001-05 U/UTP cat6 jumper, LSZH grey, 5 m 1 Category 6A Part Number Description Q.ty/pkg 70-030-021-01 U/UTP cat6A jumper, LSZH grey, 1 m 1 70-030-021-02 U/UTP cat6A jumper, LSZH grey, 2 m 1 70-030-021-03 U/UTP cat6A jumper, LSZH grey, 3 m 1 70-030-021-05 U/UTP cat6A jumper, LSZH grey, 5 m 1 UNSHIELDED JUMPERING Cat 6/Class E UTP 9 CAT6 UTP CABLES LAN Cable Cat 6/Class E U/UTP 4x2x23AWG 10-110-001-X0 Central cross design CAT6 UTP CABLES Supersedes ETA/TIA 568B.2.1 providing large headroom Construction Conductor 23AWG solid copper Insulation PE Pair separation Plastic cross Jacket PVC or LSZH, grey Mechanical Bending radius 0-50°C (installing) Operating temp. Fire resistance RoHS F RL IL MHz dB dB/100m -20+60°C (operating) Safety NEXT PSNEXT ELFEXT PSELFEXT dB dB dB/100m dB/100m 1 20.0 2.0 74.3 72.3 67.8 64.8 IEC 60332-1 4 23.0 3.8 65.3 63.3 55.8 52.8 NF C 32-070 2.1 10 25 6.0 59.3 57.3 47.8 44.8 IEC 60754-1 16 25 7.6 56.2 54.2 43.7 40.7 IEC 60754-2 20 25 8.52 54.8 52.8 41.8 38.8 IEC 61034 31.25 23.6 10.7 51.9 49.9 37.9 34.9 2002/95/EC 62.5 21.5 15.5 47.4 45.4 31.9 28.9 100 20.1 19.9 44.3 42.3 27.8 24.8 Transmission standards 125 19.4 22.5 42.8 40.8 25.9 22.9 ISI/IEC 11801 CLASS E 200 18.0 29.1 39.8 37.8 21.8 18.8 En 50173 250 17.3 33.0 38.3 36.3 19.8 16.8 EIA/TIA 568B.2.1 Part Number 10 ≥ 50 mm (installing) Description Q.ty/pkg 10-110-001-00 4x2x23AWG category 6 U/UTP cable, grey PVC jacket Box 305 mtr 10-110-001-10 4x2x23AWG category 6 U/UTP cable, grey LSZH jacket Box 305 mtr CAT6A UTP CABLES LAN Cable Cat 6A/Class EA U/UTP 4x2x23AWG 10-110-021-X0 Supersedes ETA/TIA 568B.2.10 providing large headroom Construction Conductor 23AWG solid copper Insulation PE Pair separation Plastic cross Jacket PVC or LSZH, grey F RL IL NEXT PSNEXT ELFEXT PSELFEXT MHz dB dB/100m dB dB dB/100m dB/100m Mechanical Bending radius ≥ 50 mm (installing) Operating temp. 1 20.0 2.0 77 75 71 68 0-50°C (installing) 4 23.0 3.8 68 66 59 56 -20+60°C (operating) 10 25 6.0 62 60 51 48 16 25 7.6 59 57 47 44 20 25 8.5 58 56 45 42 Safety IEC 60332-1 31.25 23.6 10.7 55 53 41 38 NF C 32-070 2.1 62.5 21.5 15.4 50 48 35 32 IEC 60754-1 100 20.1 19.8 47 45 31 28 IEC 60754-2 200 18.0 29.1 43 41 25 22 IEC 61034 250 17.3 32.8 41 39 23 20 2002/95/EC 300 17.8 36.4 40 38 21 18 350 16.3 39.8 39 37 20 17 400 15.9 43 38 36 19 16 ISI/IEC 11801 CLASS EA 450 15.5 46 38 36 18 15 En 50173 500 15.2 48.9 37 35 17 14 Fire resistance RoHS Transmission standards EIA/TIA 568B.2.10 Part Number Description CAT6A UTP CABLES Central cross design Q.ty/pkg 10-110-021-00 4x2x23AWG category 6A U/UTP cable, grey PVC jacket Box 305 mtr 70-110-021-10 4x2x23AWG category 6A U/UTP cable, grey LSZH jacket Box 305 mtr 11 SHIELDED SOLUTIONS SHIELDED SHIELDED SOLUTIONS 12 SOLUTIONS SHIELDED TERMINATIONS Modular Termination Cat 6/Class E - Shielded Easy tooless operation Cast alloy robust construction 22-26 AWG solid conductors 568A/B cabling Supersedes EIA/TIA 568B.2.1 10G Modular Termination Cat 6A/Class EA - Shielded 70-021-021-00 Easy tooless operation Cast alloy robust construction 22-26 AWG solid conductors 568A/B cabling Supersedes EIA/TIA 568B.2.10 Common Specifications Plastic parts: High impact polycarbonate Metal body: Moulded cast alloy Flammability: V0 (UL94) Contacts: Phosphor bronze -RJ45 side: gold plated -IDC side: tin/nickel plated Conductor re-terminations: > 100 Part Number Description RJ45 TERMINATIONS 70-021-001-00 Q.ty/pkg 70-021-001-00 Category 6 tooless shielded termination 24 70-021-021-00 10G Category 6A tooless shielded termination 24 13 SHIELDED DISTRIBUTION Patch Panel Unloaded 24 ports 1U SHIELDED DISTRIBUTION 14 70-010-101-00 Very compact design, 24 ports in 1U Fits with any Rertech termination (cat6/cat6A, UTP and shielded) Integrated and removable label holder Sturdy nickel plated brass counterframe Integrated and removable cable fixing rack Black colour Part Number Description 70-012-101-00 24 ports, 19” 1U unloaded patch panel with cable fixing rack Q.ty/pkg 1 SHIELDED JUMPERING Patch Cords Cat 6/Class E Shielded High quality moulded boot AWG24 stranded cable LSZH jacket Individual packing Patch Cords Cat 6A/Class EA Shielded 70-031-021-XY High quality moulded boot AWG24 stranded cable LSZH jacket Individual packing Category 6 Part Number Description Q.ty/pkg 70-031-001-01 Shielded cat6 jumper, LSZH grey, 1 m 1 70-031-001-02 Shielded cat6 jumper, LSZH grey, 2 m 1 70-031-001-03 Shielded cat6 jumper, LSZH grey, 3 m 1 70-031-001-05 Shielded cat6 jumper, LSZH grey, 5m 1 Category 6A Part Number Description Q.ty/pkg 70-031-021-01 Shielded cat6A jumper, LSZH grey, 1 m 1 70-031-021-02 Shielded cat6A jumper, LSZH grey, 2 m 1 70-031-021-03 Shielded cat6A jumper, LSZH grey, 3 m 1 70-031-021-05 Shielded cat6A jumper, LSZH grey, 5 m 1 SHIELDED PATCHCORDS 70-031-001-XY 15 CAT6 SHIELDED CABLE LAN Cable Cat 6/Class E F/UTP 4x2x23AWG CAT6 SHIELDED CABLE 10-111-001-30 Construction Conductor 23AWG solid copper Insulation PE Pair separation Plastic cross Screening Al foil Jacket LSZH, grey Mechanical ≥ 25 mm (operating) 0-50°C (installing) Operating temp. -20+60°C (operating) Safety Fire resistance RoHS EIA/TIA 568B.2.1 ISI/IEC 11801 CLASS E En 50173 10-111-001-30 F RL IL MHz dB dB/100m NEXT PSNEXT ELFEXT PSELFEXT dB dB dB/100m dB/100m 1 20.0 2.0 74.3 72.3 67.8 64.8 IEC 60332-1 4 23.0 3.8 65.3 63.3 55.8 52.8 NF C 32-070 2.1 10 25 6.0 59.3 57.3 47.8 44.8 IEC 60754-1 16 25 7.6 56.2 54.2 43.7 40.7 IEC 60754-2 20 25 8.52 54.8 52.8 41.8 38.8 IEC 61034 31.25 23.6 10.7 51.9 49.9 37.9 34.9 2002/95/EC 62.5 21.5 15.5 47.4 45.4 31.9 28.9 100 20.1 19.9 44.3 42.3 27.8 24.8 125 19.4 22.5 42.8 40.8 25.9 22.9 200 18.0 29.1 39.8 37.8 21.8 18.8 250 17.3 33.0 38.3 36.3 19.8 16.8 Transmission standards Part Number 16 ≥ 50 mm (installing) Bending radius Description 4x2x23AWG category 6 F/UTP cable, grey LSZH jacket PVC jacket and 305m box packing available on request Q.ty/pkg Reel 500 mtr CAT6A SHIELDED CABLE LAN Cable Cat 6A/Class EA F/UTP 10-111-021-30 Construction Conductor 23AWG solid copper Insulation PE Pair separation Plastic cross Screening Al foil Jacket LSZH, grey Mechanical ≥ 50 mm (installing) Bending radius ≥ 25 mm (operating) Operating temp. F RL IL NEXT PSNEXT ELFEXT PSELFEXT MHz dB dB/100m dB dB dB/100m dB/100m 0-50°C (installing) 1 20.0 2.0 77 75 71 68 -20+60°C (operating) 4 Safety 23.0 3.8 68 66 59 56 10 25 6.0 62 60 51 48 16 25 7.6 59 57 47 44 20 25 8.5 58 56 45 42 IEC 60332-1 31.25 23.6 10.7 55 53 41 38 NF C 32-070 2.1 62.5 21.5 15.4 50 48 35 32 IEC 60754-1 100 20.1 19.8 47 45 31 28 IEC 60754-2 200 18.0 29.1 43 41 25 22 IEC 61034 250 17.3 32.8 41 39 23 20 2002/95/EC 300 17.8 36.4 40 38 21 18 350 16.3 39.8 39 37 20 17 400 15.9 43 38 36 19 16 ISI/IEC 11801 CLASS EA 450 15.5 46 38 36 18 15 En 50173 500 15.2 48.9 37 35 17 14 Fire resistance RoHS Transmission standards EIA/TIA 568B.2.10 Part Number 10-111-021-30 Description 4x2x23AWG category 6A F/UTP cable, grey LSZH jacket PVC jacket and 305m box packing available on request CAT6A SHIELDED CABLE 4x2x23AWG Q.ty/pkg Reel 500 mtr 17 OPTICAL FIBRE SOLUTIONS OPTICAL OPTICAL NETWORKS 18 NETWORKS FIELD INSTALLABLE CONNECTORS Field Installable, no epoxy or fusion splicer needed 50-001-XYZ-DD EIA/TIA 604 compliant Factory polished connectors with integrated V-grove mechanical splice Convenient fibre termination in minutes. Few simple tools required (optical cable stripper and fibre cleaver, see tools section in this catalogue) Insertion loss: ≤0.3 dB (0.4 dB max) Return loss: ≤ - 50 dB Endurance: 500 reconnections (< 0.3dB) Available in SC and LC versions, SM and MM, for 2.0 and 0.9 mm cable dia. APC single mode versions available on request Part Number Description Q.ty/pkg 50-001-020-20 SC/PC Multimode field installable connector, 2 mm boot 1 50-001-040-20 LC/PC Multimode field installable connector, 2 mm boot 1 50-001-120-20 SC/PC Single mode field installable connector, 2 mm boot 1 50-001-120-09 SC/PC Single mode field installable connector, 0.9 mm boot 1 50-001-140-20 LC/PC Single mode field installable connector, 2 mm boot 1 50-001-140-09 LC/PC Single mode field installable 1 PRE-POLISHED CONNECTORS Optical Connectors 19 OPTICAL ADAPTERS ST/ST MM Optical Adapter 50-000-010-00 EIA/TIA 604 compliant Phosphor bronze sleeve Insertion loss: < 0.3 dB Durability: <0.2 dB (1000 mates) OPTICAL ADAPTERS 20 SC/SC Optical Adapter 50-000-X2Z-00 EIA/TIA 604 compliant Zirconia or phosphor bronze sleeve Insertion loss: < 0.3 dB Durability: <0.2 dB (1000 mates) ST Optical Adapter 50-000-X4Z-00 EIA/TIA 604 compliant Zirconia or phosphor bronze sleeve Insertion loss: < 0.3 dB Durability: <0.2 dB (1000 mates) Part Number Description Q.ty/pkg 50-000-010-00 ST/PC multimode adapter 24 50-000-020-00 SC/PC multimode adapter, beige 24 50-000-021-00 SC/PC duplex multimode adapter, beige 12 50-000-040-00 LC/PC multimode adapter, beige 24 50-000-041-00 LC/PC duplex multimode adapter, beige 12 50-000-120-00 SC/PC single mode adapter, blue 24 50-000-121-00 SC/PC duplex single mode adapter, blue 12 50-000-140-00 LC/PC single mode adapter, blue 24 50-000-141-00 LC/PC duplex single mode adapter, blue 12 Additional adapter types available on request (APC versions, FC, MTRJ, hybrid etc…) OPTICAL JUMPERS Optical Jumpers EIA/TIA 604 compliant Available with ST/SC/FC and LC connectors, simplex and duplex SMR, OM1, OM2 and OM3 cables, 0.9, 2.0 and 3.0 mm cable diameter Insertion loss ≤ 0.3 dB, return loss ≤ -40 dB (-60 dB for APC type) Durability: 500 mates, <0.2 dB 0: none 1: ST 2: SC 3: FC 5: SC 4: LC APC 6: LC Length in meters APC -H: half meter Side A connector 1: ST 2: SC 3: FC 5: SC 5 0: SIMPLEX 4: LC APC 6: LC 1 example Connector type 1: DUPLEX APC — C1 C2 T — F 0 C 3 meters 5H: 5.5 meters 84: 84 meters L — Fibre type L Fibre type 0: SMR 1: OM1 0: 0.9 mm tight 2: OM2 3: OM3 1: 2 mm blue 2: 3 mm yellow Most popular codings Part Number 03: Description Q.ty/pkg 51-111-202-01 ST/ST jumper, duplex, OM2 3mm, 1m 1 51-111-202-03 SC/SC jumper, duplex, OM2 3mm, 3m 1 51-221-202-01 SC/SC jumper, duplex, OM2 3mm, 1m 1 51-221-202-03 SC/SC jumper, duplex, OM2 3mm, 3m 1 51-441-202-01 LC/LC jumper, duplex, OM2 3mm, 1m 1 51-441-202-03 LC/LC jumper, duplex, OM2 3mm, 3m 1 51-200-000-02 SC pigtail, simplex, SMR 0.9, 2m 1 51-220-001-02 SC/SC jumper, simplex, SMR 2mm, 2m 1 51-400-000-02 LC pigtail, simplex, SMR 0.9 mm, 2m 1 51-440-001-02 LC/LC jumper, simplex, SMR 2mm, 2m 1 OPTICAL JUMPERS CODING CHART Side A connector 21 OPTICAL SUBSCRIBER OUTLETS Optical outlet 2 fibres, termination only 70-095-003-00 Compact and nice looking Suitable for field installable connectors Rear side cable entry OPTICAL OUTLETS Suitable for SC or LC adapters PC-ABS construction Dimension 86x86x23 (mm WxHxD) Optical outlet 4 fibres, splice & termination 70-095-001-00 Ergonomic, small and compact design Splicing, storage and termination functions Accurate fibre management (30 mm radius) Rear or bottom cable entry Suitable for SC or LC adapters High impact polystyrene construction Dimension 180 x 80 x 20 (mm, WxHxD) Part Number 22 Description Q.ty/pkg 70-095-003-00 Compact optical outlet, 2 fibres, 86x86 mm 1 70-095-001-00 Splice and termination optical outlet, up to 4 fibres 1 OPTICAL DISTRIBUTORS 19” Optical sub-rack 24 ports, swinging design Scope of Delivery Optical subrack: Splicing cassettes: Subrack cover: Fibre tubes, 2 mtrs long: Screw/nut pairs: Fibre circulators: Laser warning labels: Installation instructions: Part Number 1 4 1 2 4 4 3 1 1 unit, 19” rack mount Compact optical subrack for telecommunication or networking applications. Can handle 24 splices/terminations (SC, ST or LC adapters) or 48 splices/ terminations (LC duplex) Swinging design (opening left to right) simplifies cabling and access while avoiding cable/fibre stress and protecting eyes from laser light Left hand side cable entry (from top or bottom), up to 2 cables Right hand side patchcords routing 4 splicing cassettes, each handling up to 12 splices, can be individually accessed thanks to their hinged mechanism Compact splicing cassettes feature fibre storage and “8” figure (inversion of direction) Steel construction, powder painted, grey (RAL7035) Description Q.ty/pkg 50-010-010-00 24 ports, 19” 1U optical splice/ termination subrack, ST/FC type 1 50-010-020-00 24 ports, 19” 1U optical splice and termination subrack, SC/LC type 1 50-010-021-00 24 ports, 19” 1U optical splice and termination subrack, SC duplex type 1 OPTICAL DISTRIBUTORS 50-010-0XY-00 23 OPTICAL CABLES METAL ARMOURED Outdoor, metal armoured, 8-24 cores 20-101-XYZ-00 METAL ARMOURED CABLE 24 Mono-loose tube construction Corrugated steel tape + glass yarns armouring High tensile strength: 2000 N (installation) High crush resistance: 3000 N/10 cm Rodent proof 8.3 mm outside diameter (9.4 mm for 24 cores versions) HDPE outer jacket Corrugated steel tape Optical cores Filling jelly Fibergalss yarns Loose tube Part Number Description Q.ty/pkg 20-101-008-00 8 cores, G652D LWP, PE jacket 2,000 mtr 20-101-012-00 12 cores, G652D LWP, PE jacket 2,000 mtr 20-101-024-00 24 cores, G652D LWP, PE jacket 2,000 mtr 20-101-108-00 8 cores, OM1 62.5/125, PE jacket 2,000 mtr 20-101-112-00 12 cores, OM1 62.5/125, PE jacket 2,000 mtr 20-101-124-00 24 cores, OM1 62.5/125, LSZH jacket 2,000 mtr 20-101-208-00 8 cores, OM2 50/125, LSZH jacket 2,000 mtr 20-101-212-00 12 cores, OM2 50/125, LSZH jacket 2,000 mtr 20-101-224-00 24 cores, OM2 50/125, LSZH jacket 2,000 mtr 20-101-308-00 8 cores, OM3 50/125, LSZH jacket 2,000 mtr 20-101-312-00 12 cores, OM3 50/125, LSZH jacket 2,000 mtr 20-101-324-00 24 cores, OM3 50/125, LSZH jacket 2,000 mtr INDOOR-OUTDOOR CABLES Indoor/Outdoor, general purpose, 4-12 cores Mono-loose tube construction Fully dielectric High tensile strength: 1500 N (installation) Suitable for indoor and outdoor installation 7 mm outside diameter Halogen free Jacket Optical cores Loose tube Part Number Description Q.ty/pkg 20-001-004-00 4 cores, G652D LWP, LSZH jacket 2,000 mtr 20-001-008-00 8 cores, G652D LWP, LSZH jacket 2,000 mtr 20-001-012-00 12 cores, G652D LWP, LSZH jacket 2,000 mtr 20-001-104-00 4 cores, OM1 62.5/125, LSZH jacket 2,000 mtr 20-001-108-00 8 cores, OM1 62.5/125, LSZH jacket 2,000 mtr 20-001-112-00 12 cores, OM1 62.5/125, LSZH jacket 2,000 mtr 20-001-204-00 4 cores, OM2 50/125, LSZH jacket 2,000 mtr 20-001-208-00 8 cores, OM2 50/125, LSZH jacket 2,000 mtr 20-001-212-00 12 cores, OM2 50/125, LSZH jacket 2,000 mtr 20-001-304-00 4 cores, OM3 50/125, LSZH jacket 2,000 mtr 20-001-308-00 8 cores, OM3 50/125, LSZH jacket 2,000 mtr 20-001-312-00 12 cores, OM3 50/125, LSZH jacket 2,000 mtr INDOOR-OUTDOOR CABLES 20-001-XYZ-00 25 AIR-BLOWN MICRO CABLES Air blown micro cable, 12 to 144 cores 20-020-XYZ-00 AIR-BLOWN MICRO CABLES 26 Micro loose tubes construction Central FRP strength member Water-blocking yarns to prevent moisture Low friction PE jacket 1000 N tensile strength, lightweight construction 12-14-48-72 cores 96 cores 12 cores 24 cores 48 cores 144 cores 72 cores 96 cores 144 cores Cores/tube 12 12 12 12 12 12 Tubes/Fillers 1/5 2/4 4/2 6/0 8/0 12/0 Weight(kg/km) 28 28 28 28 42 55 O.D (mm) 5.9 5.9 4.9 5.9 6.9 8.7 Part Number Description Q.ty/pkg 20-020-012-00 12 cores, G652D LWP, PE jacket 4,000 mtr 20-020-024-00 24 cores, G652D LWP, PE jacket 4,000 mtr 20-020-048-00 48 cores, G652D LWP, PE jacket 4,000 mtr 20-020-072-00 72 cores, G652D LWP, PE jacket 4,000 mtr 20-020-096-00 96 cores, G652D LWP, PE jacket 4,000 mtr 20-020-044-00 144 cores, G652D LWP, PE jacket 4,000 mtr OPTICAL FTTH CABLES ARP (Aramid Reinforced Plastics or steel wire rods (x2) FTTH Subscriber Cable 20-091-XYZ-00 Low friction LSZH jacket Stee l wire s FTTH drop cable 20-092-012-00 Metal armoured, self suspending, outdoor use 2 cores, G652D fibre 2.0 x 5.0 mm cross section 600 N tensile strength (installing) Easy stripping Black PE jacket Optical Core(s) PE jacke t Part Number Description Q.ty/pkg 20-091-011-00 1 x G652D, metal, subscriber cable 2000 mtr 20-091-611-00 1 x G657A, metal, subscriber cable 2000 mtr 20-091-012-00 2 x G652D, metal, subscriber cable 2000 mtr 20-091-612-00 2 x G657A, metal, subscriber cable 2000 mtr 20-091-001-00 1 x G652D, dielectric, subscriber cable 2000 mtr 20-091-601-00 1 x G657A, dielectric, subscriber cable 2000 mtr 20-091-002-00 2 x G652D, dielectric, subscriber cable 2000 mtr 20-091-602-00 2 x G657A, dielectric, subscriber cable 2000 mtr 20-092-012-00 2 x G652D, metal, drop cable, PE 2000 mtr FTTH CABLES Optical core(s) Dielectric or metal armoured 1 or 2 cores, G652D or G657A (bending insensitive) Small design (mm 1.6 x 2.0), easy installation 100 N tensile strength (installing) Easy stripping Low friction, white LSZH jacket 27 OPTICAL FIBRE SPECIFICATIONS SINGLE MODE FIBRE SPECIFICATIONS 28 Characteristics Unit Attenuation @1310 nm dB/km Attenuation @ 1550 nm dB/km G652D ≤0.38 Max (≤0.35 avg) ≤0.25 Max (≤0.22 avg) G657A ≤0.34 ≤0.20 Chromatic dispersion 1285-1330 nm ps/nm.km ≤3.5 ≤3.5 Chromatic dispersion 1550 nm ps/nm.km ≤18.0 ≤18.0 1300 to 1324 1304 to 1322 ≤0.092 ≤0.090 ps/√km ≤0.20 ≤0.20 Cabled cut-off wavelength nm ≤1320 ≤1260 Mode field diameter @ 1310 nm µm 9.3±0.5 9.1±0.4 Core-clad concentricity error µm ≤0.8 ≤0.5 Cladding non circularity % ≤1.0 ≤0.8 Cladding diameter µm 125 ± 1.0 125 ± 0.7 Coating diameter µm 245 ± 10 245 ± 5 Zero dispersion wavelength nm Zero dispersion slope ps/nm2.km Polarization mode dispersion MULTI MODE Characteristics Unit Attenuation @1310 nm dB/km ≤3.0 ≤3.0 ≤3.0 Attenuation @ 1550 nm dB/km ≤1.0 ≤1.0 ≤1.0 Bandwidth @ 850 nm MHz.km ≥200 ≥500 ≥1500 Bandwidth @ 1300 nm MHz.km ≥500 ≥500 ≥500 Numeric aperture OM1 OM2 OM3 0.200±0.015 0.200±0.015 0.200±0.015 Core diameter µm 50 ± 2.0 50 ± 2.0 50 ± 2.0 Core non circularity % ≤2 ≤2 ≤2 Cladding diameter µm 125 ± 2.0 125 ± 2.0 125 ± 2.0 Cladding non circularity % ≤2.0 ≤2.0 ≤2.0 Core concentricity error µm ≤6 ≤6 ≤6 Coating diameter µm 245 ± 10 245 ± 10 245 ± 10 IPS INTELLIGENT PATCHING PATCHING SOLUTIONS INTELLIGENT PATCHING INTELLIGENT 29 INTRODUCING IPS I INTELLIGENT PATCHING 30 ntelligent patching systems are a combination of both hardware parts and software code providing the IT staff advanced network configuration capabilities. This job can be accomplished with various technical solutions at different sophistication levels. With IPS, we pursued the highest level of sophistication by providing a dramatically simple, yet effective, solution. IPS will save up to 30% of patching time and provide virtually zero mis-patching. IPS is based on its unique patch panels driven by the network management software, available for both category 6 unshielded and shielded networks. No specific patch cords are requested. IPS panels are characterised by multi colour LEDs on each port, and by a micro-switch sensing if the related patch cord is plugged or unplugged. Each group of patch panels (up to 16) is driven by a master patch panel which connects to the management console. IPS panels within the same group must be at a maximum distance of 2 meters. More groups of patch panels can be interconnected in a bus configuration, within a maximum distance of 1000 mtrs. IPS’s network management software intelligently handles the full network configuration: A) at the initial stage, by supporting the IT staff to set up and simulate the patching configuration; B) during the patching operation, by guiding the IT staff to cross -connect patch cords by means of clear LED indications; and, C) during standard operation, by detecting and locating unauthorized or activity and generating alert messages. Phase (B) specifically is of great support to IT staff; patching phase is guided on a step by step basis by IPS management software, as LEDs related to ports to be patched are blinking until successful patching is made. 24 ports, 1 unit IPS Patch Panel Preloaded with cat6 UTP terminations 24 ports, Category 6 UTP Works as master or slave 70-890-000-00 Inclusive of LED indicators Runs on windows™ XP™, VISTA™ or Windows™ 7 IPS management software Single user licence 70-890-100-00 Part Number Description Q.ty/pkg 70-890-000-00 24 ports, 1 unit, category 6 UTP preloaded IPS panel. 1 70-890-100-00 IPS management software individual licence 1 INTELLIGENT PATCHING INTRODUCING IPS 31 ACCESSORIES ACCESSORIES ACCESSORIES 32 WORKSTATION Workstation faceplate 86 x 86 70-090-00X-00 Back Box 86x86 WORKSTATION 70-090-999-00 Modular adapter 22.5x45 and 45x45 70-091-00X-00 Faceplate frame 80x80 (45x45 adapters) 70-091-100-00 Back Box 80x80 70-091-999-00 Part Number Description Q.ty/pkg 70-090-001-00 1 port 86x86 faceplate with shutter 1 70-090-002-00 2 ports 86x86 faceplate with shutter 1 70-091-001-00 22.5x45 mm adapter with shutter 1 70-091-002-00 45x45 mm adapter with shutter 1 70-091-100-00 80x80 frame (internal 45x45) 1 70-090-999-00 86x86 surface mount back box 1 70-091-999-00 80x80 surface mount back box 1 33 VOICE PRODUCTS Modular termination Category 3 UTP termination 70-020-000-00 6p6c RJ11 modular jack Tooless termination, 23-24AWG White colour VOICE PRODUCTS Voice Patch Panel 50 ports cat3 patch panel 70-010-111-00 19”, 1 Unit, robust construction 110™ tool operated termination 10 pair voice connector Disconnection module 30-010-011-00 Superior quality PBT construction Category 5 performance 1.5µm silver plated terminals Can also mount on vertical rods with included earthing clips—also providing grounding facility for easy installation of surge protections Part Number 34 Description 70-020-000-00 Category 3 UTP termination, RJ11 6p6c, tooless, white 70-010-111-00 50 ports, Category 3 , 19” 1U patch panel 30-010-011-00 10 pair disconnection module, 1-0 numbering, with clips Q.ty/pkg 10 1 10 VOICE CABLE PLUGS Multi pair cable Category 3 UTP multi-pair cable 70-120-XXX-00 24AWG solid copper conductors LSZH grey jacket Crimp type RJ45 Plug Category 6 unshielded 70-030-999-00 8p8c plug Gold plated contacts Crimp type RJ45 Plug Category 6 shielded 70-031-999-00 8p8c plug Gold plated contacts Part Number Description Q.ty/pkg 10-120-025-00 25x2x24AWG category 3 cable, LSZH grey jacket, indoor 500 10-120-050-00 50x2x24AWG category 3 cable, LSZH grey jacket, indoor 500 10-120-100-00 100x2x24AWG category 3 cable, LSZH grey jacket, indoor VOICE CABLE - PLUGS Available in 25, 50 and 100 pairs 500 70-030-999-00 RJ45 8p8c category 6 unshielded crimp-type plug 100 70-031-999-00 RJ45 8p8c category 6 shielded crimp type plug 100 35 TOOLS Insertion Tool LSA-PLUS™ type 70-900-001-00 Insertion Tool 110™ type 70-900-002-00 TOOLS Crimping tool Works on RJ11 and RJ45 plugs 70-900-003-00 Optical cable stripper Strips different cable diameters 70-900-004-00 Strips outer jacket from 2.0-2.4 mm, 2.8-3.0 mm and 2.0-3.0 loose tube fiber Strips 900um buffer from loose buffer without removing acrylate Strips buffer and acrylate from 900/125µm and 250/125µm fiber Part Number 36 Description Q.ty/pkg 70-900-001-00 LSA-PLUS™ insertion tool 1 70-900-002-00 110™ insertion tool 1 70-900-003-00 Plug crimping tool 1 70-900-004-00 Universal optical cable stripper 1 TOOLS Installer’s toolkit 70-900-010-00 “must have” basic tools housed in a sturdy and robust portable case. Includes: RJ11 and RJ45 crimp tool Soldering iron 110™ and LSA-PLUS™ insertion tools Cable stripper Network tester ...and more Fibre Cleaver 70-900-015-00 Reliable and lightweight precision fibre cleaver TOOLS Pliers and screwdrivers set Precisely cuts multimode and singlemode 125 µm bare fibres with 250 or 900 µm outer coating Cutting angle: 90° ±0.5°, length 5-30 mm Up to 20,000 quality cleaves using the same blade Part Number Description Q.ty/pkg 70-900-010-00 Installer’s toolkit 1 70-900-015-00 Precision fibre cleaver 1 37 Italy Office Phone +39 011 728422 [email protected] Middle East Office Phone +971 4 4230877 [email protected] www.rertech.it Product information and specifications reported in this document are deemed to be accurate on the date of publication as far as product comparison and ordering information are concerned. However, accuracy and completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. The user assumes all risks and liabilities in connection with the use of a product or its applications. Rertech reserves the right to change at any time and without notice design, specifications, function, fit or form of its products described herein, including withdrawal at any time of a product offered for sale herein. Rertech and Rertech logo are registered trademarks. Unauthorized use of such registered trademarks is illegal and will be prosecuted © Rertech - Rev1.01 - March 2011 - All rights reserved