Troubleshooting
Drying Tumblers 25 Pound Capacity 30 Pound Capacity 35 Pound Capacity Through Serial No. 0602004143 Refer to Page 5 for Model Numbers
1 SELEC TEMP T
2 INSER COIN T
3 PUSH START
HIGH TEMP
MED TEMP
25 C
STAR T LOW TEMP
NO HEAT
T463PE1A
www.comlaundry.com
Part No. 70284701R2 September 2007
Table of Contents
Section 1 – Safety Information ...............................................................3 Locating an Authorized Service Person ................................................4 Safety Warnings and Decals..................................................................5 Safety Precautions for Servicing Tumblers ...........................................5 Section 2 – Introduction ..........................................................................6 Model Identification ..............................................................................6 Serial Plate Location..............................................................................8 Customer Service...................................................................................8 Wiring Diagram.....................................................................................8 How a Tumbler Works ..........................................................................9 Section 3 – Troubleshooting..................................................................10 1. Tumbler Does Not Start ..............................................................11 2. Motor Does Not Start..................................................................12 3. Motor Overload Protector Cycles Repeatedly ............................13 4. Motor Runs But Cylinder Does Not Turn...................................14 5. Motor Does Not Stop ..................................................................15 6. Burner Does Not Ignite ...............................................................16 7. Burner Ignites and Goes Out Repeatedly....................................19 8. Burner Does Not Shut Off ..........................................................21 9. Clothes Do Not Dry ....................................................................22 10. Tumbler Overheating ..................................................................24 11. Burner Not Burning Properly......................................................25 12. Loading Door Opens During Operation......................................26 13. Cylinder Continues to Spin with Door Open ..............................27 14. Coin Does Not Fall into Coin Vault or Coin Drop Sensor Does Not Register that Coin Has Been Entered .........................28 Section 4 – Electronic Control Troubleshooting.................................29 15. Theory of Operation of Instant Electronic Ignition ....................29 16. Cannot Perform Infrared (IR) Communication...........................30 17. Coins Ignored When Entered......................................................31 18. Control Display – Door Open Light “On” ..................................32 19. Control Display – “Door” Error On Tumblers With 24 Volt EDC Controls..............................................................................33 20. Control Display – No Visible Display – OPL Microprocessor Models...............................................................34 21. Control Display – No Visible Display – Power On ....................35 22. Will Not Start – Electric – Manual Timer...................................36 23. Will Not Start – Electric – Rotary Coin Drop.............................37 24. Will Not Start – Gas – Manual Timer.........................................39 25. Will Not Start – Gas – Rotary Coin Drop...................................40 26. Will Not Start – Steam – Manual Timer .....................................42 27. Will Not Start – Steam – Rotary Coin Drop ...............................43 28. Will Not Start/Continue Running – EDC Control ......................45 29. Will Not Start/Continue Running – OPL Microprocessor Control ........................................................................................48
© Copyright 2007, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. 70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46.
Will Not Run – Electric – Manual Timer ...................................51 Will Not Run – Electric – Rotary Coin Drop..............................54 Will Not Run – Gas – Manual Timer..........................................57 Will Not Run – Gas – Rotary Coin Drop....................................59 Will Not Run – Steam – Manual Timer......................................61 Will Not Run – Steam – Rotary Coin Drop ................................63 Will Not Heat – Electric – Manual Timer...................................65 Will Not Heat – Electric..............................................................67 Will Not Heat – Electric – Rotary Coin Drop (With and Without Time Delay Board) .......................................................69 Will Not Heat – Electric/Gas – OPL Microprocessor.................71 Will Not Heat – Gas – EDC Models...........................................74 Will Not Heat – Gas – Manual Timer.........................................76 Will Not Heat – Gas – Rotary Coin Drop...................................78 Will Not Heat – Steam – EDC Models .......................................80 Will Not Heat – Steam – Manual Timer .....................................82 Will Not Heat – Steam – OPL Microprocessor ..........................84 Will Not Heat – Steam – Rotary Coin Drop ...............................87
Section 5 – Micro Display Control Troubleshooting ..........................89 47. Coins Ignored When Entered......................................................89 48. Control Has No Display..............................................................90 49. Door Open Indicator ...................................................................92 50. Motor Will Not Start/Run ...........................................................94 51. Unit Will Not Heat (Gas) ............................................................98 52. Unit Will Not Heat (Steam) ......................................................101 53. Unit Will Not Heat (Electric)....................................................104 54. Error Codes ...............................................................................107 Gas Models Schematic ........................................................................................108 Connection Diagram .......................................................................109 Steam Models Schematic ........................................................................................110 Connection Diagram .......................................................................111 Electric Models Schematic ........................................................................................112 Connection Diagram .......................................................................113 Section 6 – NetMaster Troubleshooting ............................................114 55. No IR Communication ..............................................................114 56. Coins Ignored When Entered....................................................115 57. Control Has No Display............................................................116 58. Door Open Indicator .................................................................119 59. Motor Will Not Start/Run .........................................................122 60. Unit Will Not Heat (Gas) .........................................................128 61. Unit Will Not Heat (Steam) ......................................................132 62. Unit Will Not Heat (Electric) ...................................................136
2
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Section 1 Safety Information Throughout this manual and on machine decals, you will find precautionary statements (“CAUTION”, “WARNING”, and “DANGER”) followed by specific instructions. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine.
DANGER Danger indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.
WARNING Warning indicates a hazardous situation that, if not avoided, could cause severe personal injury or death.
In the interest of safety, some general precautions relating to the operation of this machine follow.
WARNING • Failure to install, maintain and/or operate this product according to the manufacturer’s instructions may result in conditions which can produce serious injury, death and/or property damage. • Do not repair or replace any part of the product or attempt any servicing unless specifically recommended or published in this Service Manual and unless you understand and have the skills to carry out the servicing. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the product is properly grounded and to reduce the risk of fire, electric shock, serious injury or death.
CAUTION
W006R2
Caution indicates a hazardous situation that, if not avoided, may cause minor or moderate personal injury or property damage.
Additional precautionary statements (“IMPORTANT” and “NOTE”) are followed by specific instructions. IMPORTANT: The word “IMPORTANT” is used to inform the reader of specific procedures where minor machine damage will occur if the procedure is not followed. NOTE: The word “NOTE” is used to communicate installation, operation, maintenance or servicing information that is important but not hazard related.
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3
Safety Information
IMPORTANT INFORMATION: During the lifetime of a tumbler, it may require service. The information contained in this manual was written and is intended for use by qualified service technicians who are familiar with the safety procedures required in the repair of a tumbler, and who are equipped with the proper tools and testing equipment.
NOTE: The WARNING and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and carefulness are factors which CANNOT be built into this tumbler. These factors MUST BE supplied by the person(s) installing, maintaining or operating the tumbler. Always contact your dealer, distributor, service agent or the manufacturer on any problems or conditions you do not understand.
WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Never start the tumbler with any guards/ panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded. W240
Locating an Authorized Service Person Alliance Laundry Systems is not responsible for personal injury or property damage resulting from improper service. Review all service information before beginning repairs. Warranty service must be performed by an authorized technician, using authorized factory parts. If service is required after the warranty expires, Alliance Laundry Systems also recommends contacting an authorized technician and using authorized factory parts.
WARNING Repairs that are made to your products by unqualified persons can result in hazards due to improper assembly or adjustments subjecting you or the inexperienced person making such repairs to the risk of serious injury, electrical shock or death. W007
CAUTION If you or an unqualified person perform service on your product, you must assume the responsibility for any personal injury or property damage which may result. The manufacturer will not be responsible for any injury or property damage arising from improper service and/or service procedures. W008
4
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Safety Information
Safety Warnings and Decals SAFETY WARNINGS and decals have been provided in key locations to remind you of important precautions for the safe operation and maintenance of your tumbler. Please take the time to review these warnings before proceeding with service work. All decals have been designed and applied to withstand washing and cleaning. Decals should be checked periodically to be sure they have not been damaged, removed, or painted.
Safety Precautions for Servicing Tumblers Prior to servicing tumbler: • Disconnect electrical service and “lockout” to prevent unintentional connection. • Shut off supply gas valve. • Allow machine to cool prior to servicing.
After servicing tumbler: • Control/access panels must be reinstalled. • Motor/drive/belt guards must be reinstalled. • Contactor/junction/accessory box covers must be reinstalled. • Use a non-corrosive leak detection solution to check all pipe connections for gas leaks. DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS! • The loading door switch, lint door switch and airflow switch must be operating properly.
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
5
Section 2 Introduction Model Identification Information in this manual is applicable to these models: Gas
Steam
Electric
25 Pound
CHD25G2-CA025L CHD25G2-CA025N CHD25G2-CT025L CHD25G2-CT025N CHD25G2-CU025L CHD25G2-CU025N DR25G2-BA025L DR25G2-BA025N DR25G2-BT025L DR25G2-BT025N DR25G2-BU025L DR25G2-BU025N HA025L HA025N
HT025L HT025N HU025L HU025N IPD25G2-IT025L IPD25G2-IT025N LT025L LT025N PA025L PA025N PT025L PT025N PU025L PU025N
SA025L SA025N ST025L ST025N SU025L SU025N UA025L UA025N UT025L UT025N UU025L UU025N YT025L YT025N
CHD25S2-CT025S CHD25S2-CU025S DR25S2-BT025S DR25S2-BU025S HT025S HU025S IPD25S2-IT025S PT025S PU025S ST025S SU025S UT025S UU025S YT025S
CHD25E2-CT025E CHD25E2-CU025E DR25E2-BT025E DR25E2-BU025E HT025E HU025E IPD25E2-IT025E PT025E PU025E ST025E SU025E UT025E UU025E YT025E
30 Pound
CHD30G2-CA030L CHD30G2-CA030N CHD30G2-CT030L CHD30G2-CT030N CHD30G2-CU030L CHD30G2-CU030N HA030L HA030N HT030D HT030L HT030N HU030L HU030N
IPD30G2-IT030L IPD30G2-IT030N LT030L LT030N LU030L LU030N PA030L PA030N PT030L PT030N PU030L PU030N SA030L
SA030N ST030L ST030N SU030L SU030N UA030L UA030N UT030L UT030N UU030L UU030N YT030L YT030N
CHD30S2-CT030S CHD30S2-CU030S HT030S HU030S IPD30S2-IT030S PT030S PU030S ST030S SU030S UT030S UU030S YT030S
CHD30E2-CT030E CHD30E2-CU030E HT030E HU030E IPD30E2-IT030E LU030E PT030E PU030E ST030E SU030E UT030E UU030E YT030E
35 Pound
AT035L AT035N CHD35G2-CA035L CHD35G2-CA035N CHD35G2-CT035L CHD35G2-CT035N CHD35G2-CU035L CHD35G2-CU035N DR35G2-BA035L DR35G2-BA035N DR35G2-BT035L DR35G2-BT035N DR35G2-BU035L DR35G2-BU035N HA035L HA035N
HT035L HT035N HU035L HU035N IPD35G2-IT035L IPD35G2-IT035N LT035L LT035N LU035L LU035N PA035L PA035N PT035L PT035N PU035L PU035N
SA035L SA035N ST035L ST035N SU035L SU035N UA035L UA035N UT035L UT035N UU035L UU035N YT035L YT035N
AT035S CHD35S2-CT035S CHD35S2-CU035S DR35S2-BT035S DR35S2-BU035S HT035S HU035S IPD35S2-IT035S PT035S PU035S ST035S SU035S UT035S UU035S YT035S YU035S
CHD35E2-CT035E CHD35E2-CU035E DR35E2-BT035E DR35E2-BU035E HT035E HU035E IPD35E2-IT035E LU035E PT035E PU035E ST035E SU035E UT035E UU035E YT035E YU035E
NOTE: Control suffixes listed on next page.
6
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Introduction
Includes models with the following control suffixes: 3O - DX4 OPL 3V - DX4 vended 3X - DX4 prep for coin BC – basic electronic, coin BL – basic electronic, central pay BX – basic electronic, prep for coin BY – basic electronic, prep for card CD – rotary coin drop CX – prep for coin drop
70284701
CY – prep for card DO - DMP OPL DV - DMP vended DX - DMP prep for coin EC – EDC electronic coin EX – EDC coin ready EY – EDC card ready MT – manual timer NC – NetMaster coin
NR – NetMaster card NX – NetMaster coin ready NY – NetMaster card ready OM – OPL micro ZC – NetMaster coin network ZR – NetMaster card network ZX – NetMaster coin ready network ZY – NetMaster card ready network
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7
Introduction
Serial Plate Location When calling or writing about your product, be sure to mention model and serial numbers. Model and serial numbers are located on serial plate as shown.
ANS 72152 CLOTHES DRYER. VOL II
MODEL NO: TESTED FOR NATURAL & LIQUID PETROLEUM GASSES
SERIAL NO: V-/
HERTZ/
AMPS,
PHASE
CGA 72
WIRES + GROUND
TOTAL kW,
MOTOR kW AMPLFIEDRER
REQ'D CIRCUIT BREAKER:
AMPS
FAN OUTPUT: @MAX "WC STATIC PRESSURE EQUIPPED FOR: MIN SUPPLY PRESSURE:
INPUT:
"WC. BTU/hr @
GAS@
"WC MANIFOLD PRESS.
MAX SUPPLY PRESSURE:
"WC.
BTU/cu.ft.
MADE IN U.S.A./FABRIQUE AU ETATS UNIS/FABRICADO EN LOS ESTADOS UNIDOS
70051001
MODEL NO: SERIAL NO:
TMB1823N
Customer Service If literature or replacement parts are required, contact the source from which the machine was purchased or contact Alliance Laundry Systems at (920) 748-3950 for the name and address of the nearest authorized parts distributor. For technical assistance, call (920) 748-3121.
Wiring Diagram The wiring diagram is located inside the contactor or junction box. Models starting Serial No. 0309____ or later will have the wiring diagram part number in the lower portion of the electrical data on the serial plate.
8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Introduction
How a Tumbler Works A tumbler uses heated air to dry loads of laundry. 1
When the motor is started, the exhaust fan pulls room temperature air in through the air intake at the rear of the tumbler and over the heat source (burner flame for gas, heating element for electric, and coil for steam).
2
The heated air moves into the cylinder, where it is circulated through the wet load by the tumbling action of the cylinder.
3
The air then passes through the lint filter, exhaust fan, and is vented to the outdoors.
1
2
3
T001CE3A
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
9
Section 3 Troubleshooting WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. • Never start the tumbler with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded. W002
IMPORTANT: Refer to wiring diagram for aid in testing tumbler components.
10
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Troubleshooting
1. Tumbler Does Not Start Tumbler Does Not Start Is loading door open? Is the electrical power off or circuit breaker or fuse blown?
Yes
Check power supply, or replace fuses.
Close loading door completely.
Yes
No
Is the lint panel open?
Yes
Close and lock lint panel.
No No Is there a blown fuse on tumbler?
Check fuse (in junction box) and replace if necessary.
Yes
No
Is there an incorrect amount of coins inserted into coin drop? (Rotary Coin Drop Models Only)
Is drying timer in an off position (Manual Timer Models)?
Yes
Turn drying timer on.
No Check that Yes proper amount of coins are inserted.
Is the PUSH-TO-START button not properly activated (Manual Timer Models)?
Yes
Press and hold PUSH-TOSTART button for three seconds.
No No
Is coin drop inoperative? (Rotary Coin Drop Models Only)
Yes
Test coin drop and replace if inoperative.
Is motor relay inoperative?
Yes
Test relay and replace if necessary.
No TMB2181S 70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
11
Troubleshooting
2. Motor Does Not Start Motor Does Not Start
Is the electrical power off or circuit breaker fuse blown?
Is there broken, loose, or incorrect wiring?
Yes
Refer to wiring diagram.
No Yes
Check power supply, or replace fuses.
Is the fan or fan motor binding?
Yes
Replace fan or motor assembly.
No No Is the loading door switch or lint panel switch not closed or switch inoperative?
Yes
Close door, panel or test switch and replace if inoperative.
Yes
Refer to Adjustments Section for door switch adjustment.
Is the transformer inoperative?
Yes
Test and replace if necessary.
Yes
Test relay and replace if inoperative.
No
No
Is the start circuit not complete?
Replace cylinder, bearing, rollers, or motor assembly.
Yes
No
No Is the door switch improperly adjusted?
Is the cylinder or cylinder motor binding?
Yes
Press and hold PUSH-TO-START button for three seconds.
Is the motor relay inoperative?
No No
Is the motor inoperative?
Yes
Have motor tested and replace if inoperative.
Is the airflow switch inoperative (Manual Timer and Rotary Coin Drop Models)?
Yes
Test switch, replace or adjust as required.
No TMB2190S 12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Troubleshooting
3. Motor Overload Protector Cycles Repeatedly Motor Overload Protector Cycles Repeatedly
Yes
Is voltage correct? No Is clothes load too large?
Yes
Refer to Installation Manual for electrical requirements.
Remove part of load.
No Is clothes cylinder binding?
Yes
Check cylinder for binding.
No
Yes
Is wiring adequate?
Check with local power company to ensure that wiring is adequate.
No
Yes
Is make-up air adequate?
Refer to Installation Manual for make-up air requirements.
No Is there lint buildup around tumbler or poor maintenance?
No
Clean lint accumulation on and around the motors.
Yes
Is there broken, loose or incorrect wiring?
Yes
Refer to wiring diagram.
TMB1904S 70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
13
Troubleshooting
4. Motor Runs But Cylinder Does Not Turn
Motor Runs But Cylinder Does Not Turn
Is cylinder belt broken?
Yes
Replace cylinder belt.
No
Has belt jumped off idler?
Yes
Replace belt on idler.
No
Is cylinder binding?
Yes
Check cylinder for binding.
TMB2182S
14
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Troubleshooting
5. Motor Does Not Stop Motor Does Not Stop
Is the door switch or lint panel switch not working properly?
Yes
Test switches and replace if inoperative.
No
Is coin drop not working properly?
Yes
Test coin drop and replace if inoperative.
No
Is wiring incorrect?
Yes
Refer to wiring diagram.
No
Is electronic control inoperative?
Yes
Replace electronic control.
Yes
Test relay and replace if inoperative.
No
Is motor relay inoperative?
TMB2038S
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
15
Troubleshooting
6. Burner Does Not Ignite Burner Does Not Ignite
Is the airflow switch inoperative?
Is there an improper or inadequate exhaust system?
Yes
Refer to Installation Manual for exhaust system requirements.
No
Are there blown fuses or Yes tripped circuit breakers in external electric supply line?
Yes
Reset cycle on microprocessor.
Yes
Is stove limit thermostat 1 inoperative?
Is stove limit thermostat 2 inoperative? (Gas Models Only)
No
Test thermostat and replace if inoperative.
No
No
Is motor relay inoperative?
Yes
Test relay and replace if inoperative.
Are the orifices incorrect?
No No
16
Yes
Test thermostat 1 and replace if inoperative.
No
Is there an insufficient gas supply?
No Is the cabinet thermostat inoperative?
Test switch, replace or adjust as required.
No Check/replace fuses or reset circuit breaker.
No Is drying selector in the “Cool Down” portion of cycle?
Yes
Yes
Test thermostat 2 and replace if inoperative.
Open partially closed gas shut-off valve, or correct low gas pressure. Check manifold pressure and adjust to Yes pressure specified on serial plate. If pressure cannot be obtained, have your local gas company check main gas pressure. Tumbler is equipped for type of gas specified on serial Yes plate. If orifices are different from that specified on serial plate, obtain and install correct orifices.
Continued on next page
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
TMB2183S-a
70284701
Troubleshooting
6. Burner Does Not Ignite (continued) Continued from previous page
Is there lint buildup?
Yes
Clean lint compartment. Check damper for lint accumulation. Check ductwork for lint buildup.
No
Is there inadequate ductwork and make-up air?
Refer to Installation Manual to ensure Yes that ductwork and make-up air openings are sized accurately.
Yes
Test switch and replace if inoperative.
Is the lint panel not closed properly?
Yes
Unlock and open lint panel. Close panel ensuring a tight fit, then lock.
No Is there broken, loose or incorrect wiring?
No
Are valve coils inoperative?
Yes
Refer to wiring diagram.
Clearance should be 0.110 - 0.140 inch (2.79 - 3.55 mm).
Check valve coils and replace if necessary.
Yes
No Check fuse (located in control box) and replace if necessary.
Yes
No Is gas shut-off valve in the closed position?
No
Yes
No
Is there a blown fuse on tumbler?
No
Is the airflow switch inoperative?
Is there an improper igniter to burner tab clearance?
Yes
Open shutoff valve.
No
Is the ground wire from Instant Electronic Ignition (IEI) board not connected to ground terminal?
No
Yes
Connect ground wire to ground terminal.
Continued on next page TMB2183S-b
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
17
Troubleshooting
6. Burner Does Not Ignite (continued) Continued from previous page
Is the IEI control inoperative?
Yes
Replace IEI control.
Is Instant Electronic Ignition (IEI) control in safety lockout?
Yes
Reset IEI control by opening and closing loading door. (NonCE models only) Reset IEI by pressing reset button on back of unit. (CE models only)
No No Is fan motor switch inoperative?
Yes Replace motor. Is the thermistor inoperative?
Yes
Replace thermistor.
No Is there an inoperative accumulator switch (rotary coindrop) or C1 relay (timer models)?
No Yes Test and replace as needed. Is the temperature control or heat control relay inoperative?
No
Is wrong transformer configuration harness installed?
NOTE: Ohm value should be 45000 at 80˚ F.
Yes
Yes
Replace controls or heat control relay.
Check incoming voltage and install correct configuration harness.
No
TMB2183S-c
18
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Troubleshooting
7. Burner Ignites and Goes Out Repeatedly Burner Ignites and Goes Out Repeatedly
Is there insufficient gas pressure?
Yes
Check gas supply and pressure.
Tumbler is equipped for type of gas specified on serial Yes plate. If orifices are different from that specified on serial plate, obtain and install correct orifices.
Does tumbler have improper orifices?
No
No
Is the cabinet thermostat inoperative?
Yes
Test thermostat and replace if inoperative.
Is there broken, loose or incorrect wiring?
Yes
Refer to wiring diagram.
No No
Is stove limit thermostat 1 inoperative?
Yes
Test thermostat 1 and replace if inoperative.
Is there excessive igniter to burner clearance?
Yes
Clearance should be 0.110 - 0.140 inch (2.79 - 3.55 mm).
No No Is stove limit thermostat 2 inoperative?
Yes
Test thermostat 2 and replace if inoperative.
Is there inadequate make-up air?
Yes
Refer to Installation Manual for make-up air requirements.
No No
Is the exhaust system improper or inadequate?
No
70284701
Yes
Refer to Installation Manual for exhaust system requirements.
Is the thermistor inoperative?
Yes
Replace thermistor.
No Continued on next page
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
TMB2184S-a
19
Troubleshooting
7. Burner Ignites and Goes Out Repeatedly (continued)
Continued from previous page
Is the control heater relay malfunctioning?
Yes Replace control.
No
Are the back draft dampers locked in closed position?
Yes
Repair damper to working order.
Yes
Replace high tension lead.
Yes
Replace ignitor.
No
Is the high tension lead shorted?
No
Is the ignitor cracked?
TMB2184S-b
20
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Troubleshooting
8. Burner Does Not Shut Off
Burner Does Not Shut Off
Are there impurities on gas valve seat, preventing valve from closing?
Yes
Replace gas valve.
No
Is wiring correct?
Yes
Refer to wiring diagram.
No
Is control heater relay malfunctioning?
Yes
Replace control.
TMB1909S
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
21
Troubleshooting
9. Clothes Do Not Dry Clothes Do Not Dry
Is there enough heating time allocated for the load?
Yes
Start cycle again with enough time to dry load.
Does the burner ignite and go out repeatedly?
Refer to Burner Ignites and Goes Out Repeatedly flowchart.
Yes
No No
Is the burner not igniting?
Yes
Refer to Burner Does Not Ignite flowchart.
Is the drying selector improperly set?
Set selector for higher setting.
Yes
No No
Is there too much water in articles being dried?
Is the voltage incorrect? Yes
Remove excess water.
No
Is the clothes load too large?
Yes
Remove part of load. Maximum load is 25 pound dry weight (cotton load) for 25 pound tumbler, etc.
No
Is the exhaust system improper or inadequate?
Yes
Refer to Installation Manual for exhaust system equirements.
Yes
Refer to Installation Manual for electrical requirements.
Yes
Refer to Installation Manual for make-up air requirements.
No
Is there inadequate make-up air? No Is the exhaust duct to the outside blocked?
Yes
Clean duct to remove blockage.
No
Continued on next page No
TMB2185S-a 22
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Troubleshooting
9. Clothes Do Not Dry (continued) Continued from previous page
Is the lint screen clogged?
Yes
Clean/replace lint screen.
No
Is the thermistor inoperative?
Yes
Replace thermistor.
No
Is the exhaust damper binding?
Yes
Adjust damper so it turns freely.
No
Is the cylinder speed too fast?
Yes
Check belt is not riding on outer diameter of motor pulley.
NOTE: 25 and 30 pound tumblers = 50 rpm 35 pound tumlers = 46 rpm
TMB2185S-b
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
23
Troubleshooting
10. Tumbler Overheating Tumbler Overheating
Does tumbler have incorrect main burner orifices?
Is the thermistor sensor inoperative? Yes
Obtain and install correct orifices. No Is the exhaust damper binding?
No
Is gas Yes pressure too high or low?
Adjust gas pressure as specified on serial plate.
Yes
Refer to Installation Manual for make-up air requirements.
No
Is there lint buildup?
Yes
Clean lint compartment. Check damper for lint accumulation. Check ductwork for lint buildup.
No
Is the exhaust system restricted or inadequate?
No
Yes
Remove obstruction or lint build up from exhaust ductwork. Refer to Installation Manual for exhaust system requirements.
Yes
Adjust damper so it turns freely.
No
Is the control heater relay malfunctioning?
No
Is the make-up air inadequate?
Yes
Check wiring to ensure thermistor is connected. Replace thermistor if necessary. Remove lint buildup on thermistor.
Yes
Replace control.
No Are the safety covers missing, allowing cool air to enter tumbler?
Yes
Replace covers.
No Is the lint screen clogged with fabric softener?
Yes
Replace lint screen.
No
Are there holes in cabinets due to foreign objects?
Yes
Repair/replace cabinet components. TMB1911S
24
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Troubleshooting
11. Burner Not Burning Properly Burner Not Burning Properly
Is there lint/dirt in burner tube?
Yes
Disassemble burner and blow out the dirt.
No
No
Yes
No
Is the exhaust duct restricted or blocked?
Yes
Replace airflow switch.
No
Is the gas Yes pressure too high or low?
Does the tumbler have incorrect orifices?
Is the airflow switch not functioning properly?
Yes
Check serial plate on back of tumbler for correct gas pressure. Tumbler is equipped for the type of gas specified on serial plate. If orifices are different from that specified on serial plate, obtain and install correct orifices.
Is there inadequate make-up air?
Yes
Refer to Installation Manual for make-up air requirements.
No
Is there lint buildup around gas valve spud?
Yes
Clean off lint.
Disassemble and clean exhaust system.
No TMB1912S
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
25
Troubleshooting
12. Loading Door Opens During Operation
Loading Door Opens During Operation
Is tumbler improperly leveled?
Yes
Refer to Installation Manual for leveling leg adjustment.
Yes
Remove part of load and restart tumbler.
No
Is clothes load too large?
No
Is loading door strike adjusted incorrectly?
Yes
Refer to Adjustments Section for strike adjustment.
TMB1913S
26
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Troubleshooting
13. Cylinder Continues to Spin with Door Open
Cylinder Continues To Spin With Door Open
Is door switch inoperative?
Yes
Replace door switch.
No
Is motor relay inoperative?
Yes
Replace relay in control box.
TMB2186S
NOTE: All tumbler panels must be in place and on the machine for proper operation.
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
27
Troubleshooting
14. Coin Does Not Fall into Coin Vault or Coin Drop Sensor Does Not Register that Coin Has Been Entered Coin Does Not Fall Into Coin Vault or Coin Drop Sensor Does Not Register That Coin Has Been Entered
Is proper electrical power supplied to coin drop?
No
Yes
Is machine level?
No
Incorrect electrical connection may prevent coins from registering in coin drop. Refer to wiring diagram.
Machines that are not level may prevent coins from following through required check stages of drop. Refer to Installation Manual for instructions on leveling machine.
Yes
Is coin drop clean?
No
Residue or lint build-up may prevent coins from following through required check stages of drop. Clean coin drop.
Yes
Is sensor operative?
No
Replace coin drop sensor.
TMB1915S
IMPORTANT: Never use oil to correct coin drop problem. Oil residue will prevent coins from rolling properly. IMPORTANT: Do not bend or damage mechanical parts within coin drop. 28
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Section 4 Electronic Control Troubleshooting WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. • Never start the tumbler with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded. W002
15. Theory of Operation of Instant Electronic Ignition IMPORTANT: The Non-CE Marked Instant Electronic Ignition system will attempt to light the gas by sparking for approximately 12 seconds. If gas ignition does not take place within approximately 12 seconds, the Instant Electronic Ignition control will go into safety lockout and the valve will no longer open until Instant Electronic Ignition control is reset. To reset Instant Electronic Ignition control, remove power from control by opening and closing the tumbler door. If condition persists, check that the gas shut-off valve is in “on” position and that the gas service is properly connected.
70284701
If condition persists: a. Check resistance of high tension lead (approximately 1000 ohms/inch), and replace if not within resistance range. b. Check voltage present at valve. c. Check that machine is properly grounded. d. Check the igniter gap (gap should be .110 to .140 inch). e. Check that burner ports are not blocked or plugged under the igniter.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
29
Electronic Control Troubleshooting
16. Cannot Perform Infrared (IR) Communication Single and stacked. Gas and electric heat. Single and three phase supply.
Attempt to communicate with the electronic control from the microwand.
Check the following:
Is there a response of any kind from the electronic control?
NO
Aim microwand closer and try again.
YES
Does the control respond?
NO
- low battery on microwand. - is the IR window covered or blocked on the control. - if needed replace the electronic control. - is the IR cap properly attached to the microwand.
YES
Does the electronic control display E:OF or -C-?
-C-
Communication sequence checks out.
E:OF
Check the following: - IR communication disabled by manual programming. - Is the IR window on the control covered or blocked. - if needed, change electronic control board.
T027D
T027D
30
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
17. Coins Ignored When Entered Single and stacked units. Gas and electric heat. Single and three phase voltage. Start coin drop diagnostic tests.
Does the display on the control increment properly?
YES
Exit diagnostic testing and reset control. (Prompting for vend price)
NO
Is connector H2 firmly seated in its receptacle?
NO
Reconnect and run diagnostic test again.
NO
Reconnect and run diagnostic test again.
YES
Replace coin drop or optic switch.
YES
Is the 3 pin connector between coin drop and control connected correctly?
YES
Are wires exiting coin drop optical sensor cracked or broken?
NO
Replace coin drop or optic switch. If problem still exists then replace the control.
TMB1872S
TMB1872S
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
31
Electronic Control Troubleshooting
18. Control Display – Door Open Light “On” Single and stacked units. Gas and electric heat. Single and three phase supply.
Reference voltage checks to transformer neutral.
(6)
(1)
Is there voltage at H4-6 on the electronic control?
YES
Is there voltage at the input of the secondary fuse?
NO
Replace electronic control.
Correct wiring between secondary fuse and transformer.
YES NO (7)
Is there power supplied to the unit?
NO
Is there voltage to output side of secondary fuse?
NO
Replace secondary fuse.
Plug unit in and run it. YES
YES (8) (2)
Is there voltage to input of primary fuses?
NO
Correct wiring between primary fuses and power supply.
Is there voltage to N.O. of door switch?
NO
Correct wiring between N.O. and output of secondary fuse.
YES YES (9) (3)
Is there voltage to output side of the primary fuses?
NO
Replace primary fuse(s).
With door closed is there voltage to COM of door switch?
NO
Check for proper function of door switch replace if necessary.
YES YES (10) (4)
Is there voltage across terminals 1 & 2 of transformer primary?
NO
Correct wiring between primary fuses and transformer.
Is there voltage to N.O. of lint drawer switch?
NO
Correct wiring between N.O. on lint drawer and COM on door switch.
YES YES (11) (5)
Is there voltage across terminals 2 & 3 of transformer secondary?
NO
Replace transformer.
Is there voltage to COM of lint drawer switch with lint panel closed?
NO
Check for proper operation replace if necessary.
YES YES Correct wiring between H4-6 of electronic control and COM of lint drawer switch.
T028D
T028D
32
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
4
6
5
7
8
9
2
10
11
3
1
TMB1788S
19. Control Display – “Door” Error On Tumblers With 24 Volt EDC Controls
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
33
Electronic Control Troubleshooting
20. Control Display – No Visible Display – OPL Microprocessor Models Gas, steam and electric heat. Single and three phase supply.
Is there voltage supplied to the unit?
NO
Connect supply voltage and run unit.
YES
Is there voltage across fuse on OPL Micro?
NO
Replace OPL Micro.
YES
Note: Reference voltage to supply neutral. Replace fuse. Is there voltage to the input side of the primary fuse(s)?
NO
Correct wiring between primary fuse and supply.
YES
Is there voltage to the output side of the primary fuse(s)?
NO
Replace primary fuse.
YES
Is there voltage across the primary side of the transformer?
NO
Correct wiring between transformer and primary fuse.
YES
Is there voltage across 1 & 4 of transformer secondary?
NO
Replace transformer
YES
Is there voltage across terminals H3-3 & H3-4 on OPL Micro?
NO
Correct wiring between OPL Micro and transformer secondary.
YES TMB1823S
TMB1823S
34
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
21. Control Display – No Visible Display – Power On Single and stacked units. Gas and electric heat. Single and three phase supply.
Is there voltage across H4-2 & H4-5 on the EDC control?
YES
Replace EDC Control.
NO
Is there voltage at the input of the secondary fuse?
NO
Correct wiring between secondary fuse and transformer.
YES
Is there power supplied to the unit?
NO
Plug unit in and run it.
Is there voltage to output side of secondary fuse?
NO
Replace secondary fuse.
YES
YES
Is there voltage to input of primary fuses?
NO
Correct wiring between primary fuses and power supply.
Correct wiring between H4-2 and secondary fuse.
YES
Is there voltage to output side of the primary fuses?
NO
Replace primary fuse(s).
YES
Is there voltage across terminals 1 & 2 of transformer primary?
NO
Correct wiring between primary fuse and transformer.
YES
Is there voltage across terminals 2 & 3 of transformer secondary?
NO
Replace transformer.
YES
T025D
T025D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
35
Electronic Control Troubleshooting
22. Will Not Start – Electric – Manual Timer Manual Timer, with and without time delay board. Single and stacked units. Single and three phase power supply.
Is there power supply voltage coming to the tumbler?
NO
Connect power and run the cycle.
YES
Is there voltage at the primary side of the transformer at terminals 1 and 2?
NO
Change the primary Still no voltage fuse to the transformer.
Correct wiring between power supply and transformer.
For stacked units. YES
Correct wiring between upper and lower pocket.
Is there voltage at the secondary side of the transformer at terminal 2 and 3?
NO
Replace the transformer.
NO
Change the secondary fuse.
YES
Is there voltage to the output side of the secondary fuse?
YES
NOTE: White wires are transformer "neutral"
Is there voltage to the N.O. terminal of the door switch?
YES
With door closed Is there voltage at COM of the door switch?
Correct the wiring between the door switch and the secondary fuse.
With lint panel closed is there votlage to N.O. terminal of the liint panel switch?
YES
Is there voltage to the COM of the lint panel switch?
NO
NO
NO
Correct the wiring between the secondary fuse and the transformer.
NO
YES
NO Correct wiring between lint panel switch and door switch.
Check for proper operation, replace the door switch if necessary.
Refer to NO MOTOR RUN (run circuit.)
YES
Replace lint panel switch. T050D
T050D
36
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
23. Will Not Start – Electric – Rotary Coin Drop Coin Drop with and without time delay boards. Single and stacked units. Single and three phase power supply.
Is there power supply voltage coming to the unit?
NO
Connect power to the unit and run cycle.
Is there voltage across coinmeter timer motor?
NO
Correct wiring between coinmeter timer motor and COM on switch A.
YES YES Is the primary fuse good? Is there voltage at the primary side of the transformer at terminals 1 & 2?
NO
NO
Replace fuse and run machine.
YES
Is there voltage at the secondary side of the transformer at terminal 2 and 3?
NO
Is there voltage at N.O. terminal of the door switch?
Replace the transformer.
Is the secondary fuse good? NO
YES Correct wiring between secondary of transformer and fuse.
YES Note: Reference voltage to transformer neutral. (White wire) Is there voltage to N.C. terminal of switch A on rotary coin drop?
Replace coinmeter timer motor.
NO
Correct wiring between N.O. on door switch and COM on switch A.
YES
YES
Is there voltage to the output side of the secondary fuse?
NO
YES
Correct wiring between transformer and power supply.
YES
Does the coinmeter timer motor advance?
NO
Correct wiring between rotary coin drop and secondary fuse.
NO
Replace fuse and run machine.
With the door closed is there voltage across the door switch?
YES
Check door switch for proper operation, replace if necessary.
NO
Is there voltage to the N.O. terminal of the lint panel switch?
NO
Correct wiring between N.O. on the lint panel switch and COM of door switch.
YES YES
Is the unit equipped with time delay boards?
YES
Continued on next page at step 1.
With the lint panel closed is there voltage across the lint panel switch?
YES
Check lint panel switch for proper operation and replace if necessary.
NO NO Note: The following checks are made with the vend price satisfied. Is there voltage on the COM terminal of switch A?
NO
Continued on next page at step 2.
Replace switch A. Step 3 continuation.
YES
T075D
T075D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
37
Electronic Control Troubleshooting
23. Will Not Start – Electric – Rotary Coin Drop (continued) STEP 1
STEP 2
Is there voltage to H1-2 on TMR1 board?
YES
NO
Correct wiring between H1-2 and output of secondary fuse.
Is there voltage at 2A of the start switch?
YES
Note: Following tests are conducted with vend price satisfied.
With vend price satisfied is there voltage across N.C. & COM of switch A?
YES
Correct wiring between 2A of start switch and COM of lint panel switch.
NO
Replace switch A. 3 phase
Does the unit have single phase or three phase power supply?
NO Single phase Is there voltage across the timer motor?
NO
Correct wiring between timer motor and COM on switch A. Is there voltage at terminal 7 of the motor relay?
YES
Does coinmeter timer motor advance?
NO
Replace timer motor.
NO
Correct wiring between H1-6 and COM on switch A.
Correct wiring between 7 of motor relay and COM of lint panel switch.
NO
YES
Refer to NO MOTOR RUN (run circuit).
YES
Is there voltage across H1-6 & H1-8 of TMR1?
YES
Is there voltage across H1-2 & H1-3 of TMR1?
Is there voltage at terminal 14 of the motor control relay?
NO
Correct wiring to terminal 14 of motor control relay.
YES
YES
Replace TMR1.
Refer to NO MOTOR RUN (Run Circuit).
NO
Is there voltage to N.O. of door switch?
NO
Correct wiring between N.O. of door switch and H1-3 of TMR1.
YES
Continue at step 3 on previous page.
T076D
T076D
38
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
24. Will Not Start – Gas – Manual Timer No motor run (start circuit) Manual Tumblers. Single and stacked units with and without time. delay
Is there power supply voltage coming to the tumbler?
NO
Connect power and run the cycle.
NO
Change the primary Still no voltage fuse to the transformer.
YES
Is there voltage at the primary side of the transformer at terminals 1 and 2?
YES
Correct wiring between power supply and transformer.
For stacked units.
Is there voltage secondary side of the at the transformer at terminal 2 and 3?
Correct wiring between upper and lower pocket. NO
Replace the transformer.
NO
Change the secondary fuse.
YES
Is there voltage to the output side of the secondary fuse?
YES
NOTE: White wires are transformer "neutral"
Is there voltage to the input side of the door switch?
YES
Is there voltage to the output side of the door switch?
NO
Is there voltage to the output side of the lint panel switch?
YES
Is there voltage to the input side of the lint panel switch?
NO
Correct the wiring between the door switch and the secondary fuse.
NO
Correct the wiring between the secondary fuse and the transformer.
NO
YES
NO Correct wiring between lint panel switch and door switch.
Replace the door switch.
Refer to NO MOTOR RUN (run circuit).
YES
Replace lint panel switch. T041D
T041D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
39
Electronic Control Troubleshooting
25. Will Not Start – Gas – Rotary Coin Drop Single & stacked tumblers with and without time delay.
Is there power supply voltage coming to the unit?
NO
Connect power to the unit and run cycle.
Is there voltage across coinmeter timer motor?
NO
Correct wiring between coinmeter timer motor and COM on switch A.
YES YES Is the primary fuse good? Is there voltage at the primary side of the transformer at terminals 1 & 2?
NO
NO
Replace fuse and run machine. Does the coinmeter timer motor advance?
YES
Is there voltage at the secondary side of the transformer at terminal 2 and 3?
NO
Is there voltage at N.O. terminal of the door switch?
Replace the transformer.
NO
Correct wiring between N.O on door switch and COM on switch A.
YES
YES Is the secondary fuse good? Is there voltage to the output side of the secondary fuse?
Replace coinmeter timer motor.
YES
Correct wiring between transformer and power supply.
YES
NO
NO
YES Correct wiring between secondary of transformer and fuse.
YES
Note: Reference voltage to transformer neutral. (White wire) Correct wiring Is there voltage to NO between rotary coin N.C. terminal of drop and secondary switch A on rotary fuse. coin drop?
NO
Replace fuse and run machine.
With the door closed is there voltage across the door switch?
YES
Check door switch for proper operation, replace if necessary.
NO
Is there voltage to the N.O. terminal of the lint panel switch?
NO
Correct wiring between N.O. on the lint panel switch and COM of door switch.
YES YES
Is the unit equipped with time delay boards?
YES
Continued on next page at step 1.
With the lint panel closed is there voltage across the lint panel switch?
YES
Check lint panel switch for proper operation and replace if necessary.
NO NO Note: The following checks are made with the vend price satisfied. Is there voltage on the COM terminal of switch A?
NO
Continued on next page at step 2.
Replace switch A.
Step 3 continuation. T086D
YES
T086D
40
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
25. Will Not Start – Gas – Rotary Coin Drop (continued) STEP 2
STEP 1
Is there voltage to H1-2 on TMR1 board?
YES
NO
Correct wiring between H1-2 and output of secondary fuse.
YES
NO
Correct wiring between 2A of start switch and COM of lint panel switch.
YES
Note: Following tests are conducted with vend price satisfied.
With vend price satisfied is there voltage across N.C. & COM of switch A?
Is there voltage at 2A of the start switch?
Replace switch A.
Is there voltage at terminal 7 of the motor relay?
NO
Correct wiring between 7 of motor relay and COM of lint panel switch.
NO YES
Is there voltage across the timer motor?
NO
Correct wiring between timer motor and COM on switch A.
Refer to NO MOTOR RUN (run circuit).
YES
Does coinmeter timer motor advance?
NO
Replace timer motor.
NO
Correct wiring between H1-6 and COM on switch A.
YES
Is there voltage across H1-6 & H1-8 of TMR1?
YES
Is there voltage across H1-2 & H1-3 of TMR1?
YES
Replace TMR1.
NO
Is there voltage to N.O. of door switch?
NO
Correct wiring between N.O. of door switch and H1-3 of TMR1.
YES
Continue at step 3 on previous page. T087D
T087D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
41
Electronic Control Troubleshooting
26. Will Not Start – Steam – Manual Timer Single and stacked units with and without time delay boards.
Is there power supply voltage coming to the tumbler?
NO
Connect power and run the cycle.
NO
Change the primary Still no voltage fuse to the transformer
YES
Is there voltage at the primary side of the transformer at terminals 1 and 2?
YES
Correct wiring between power supply and transformer.
For stacked units. Correct wiring between upper and lower pocket.
Is there voltage at the secondary side of the transformer at terminal 2 and 3?
NO
Replace the transformer.
NO
Change the secondary fuse.
YES
Is there voltage to the output side of the secondary fuse?
YES
NOTE: White wires are transformer "neutral"
Is there voltage to the N.O. terminal of the door switch?
YES
Is there voltage to the COM terminal of the door switch?
Correct the wiring between the door switch and the secondary fuse
Is there voltage to the N.O. terminal of the lint panel switch?
YES
NO
NO
NO
Correct the wiring between the secondary fuse and the transformer.
NO
Is there voltage to the COM terminal of the lint panel switch?
YES
NO
Correct wiring between lint panel switch and door switch.
Replace the door switch.
Refer to NO MOTOR RUN (run circuit) .
YES
Replace lint panel switch. T016D
T016D
42
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
27. Will Not Start – Steam – Rotary Coin Drop Single and stacked tumblers with and without time delay.
NO
Is there power supply to the unit?
Connect power to the unit and run cycle.
NO
Is there voltage across coinmeter timer motor?
Correct wiring between coinmeter timer motor and COM on switch A.
YES YES Is the primary fuse good? Is there voltage at the primary side of the transformer at terminals 1 & 2?
NO
NO
Replace fuse and run machine. Does the coinmeter timer motor advance?
YES
Correct wiring between transformer and power supply.
YES
Is there voltage at the secondary side of the transformer at terminal 2 and 3?
NO
Replace coinmeter timer motor.
YES
Is there voltage at N.O. terminal of the door switch?
Replace the transformer.
NO
Correct wiring between N.O on door switch and COM on switch A.
YES
YES Is the secondary fuse good? Is there voltage to the output side of the secondary fuse?
NO
NO
YES Correct wiring between secondary of transformer and fuse.
YES
Note: Reference voltage to transformer neutral. (White wire) Correct wiring Is there voltage to NO between rotary coin N.C. terminal of drop and secondary switch A on rotary fuse. coin drop?
NO
Replace fuse and run machine.
With the door closed is there voltage across the door switch?
YES
Check door switch for proper operation, replace if necessary.
NO
Is there voltage to the N.O. terminal of the lint panel switch?
NO
Correct wiring between N.O. on the lint panel switch and COM of door switch.
YES YES
Is the unit equipped with time delay boards?
YES
Continued on next page column 1.
With the lint panel closed is there voltage across the lint panel switch?
YES
Check lint panel switch for proper operation and replace if necessary.
NO NO Note: The following checks are made with the vend price satisfied. Is there voltage on the COM terminal of switch A?
NO
Continued on next page column 2.
Replace switch A. Step 3 continuation.
YES
T062D
T062D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
43
Electronic Control Troubleshooting
27. Will Not Start – Steam – Rotary Coin Drop (continued) COLUMN 1
COLUMN 2
Is there voltage to H1-2 on TMR1 board?
YES
NO
Correct wiring between H1-2 and output of secondary fuse.
YES
NO
Correct wiring between 2A of start switch and COM of lint panel switch.
YES
Note: Following tests are conducted with vend price satisfied.
With vend price satisfied is there voltage across N.C. & COM of switch A?
Is there voltage at 2A of the start switch?
Replace switch A.
Is there voltage at terminal 7 of the motor relay?
NO
Correct wiring between 7 of motor relay and COM of lint panel switch.
NO YES
Is there voltage across the timer motor?
NO
Correct wiring between timer motor and COM on switch A.
Refer to NO MOTOR RUN (run circuit).
YES
Does coinmeter timer motor advance?
NO
Replace timer motor.
NO
Correct wiring between H1-6 and COM on switch A.
YES
Is there voltage across H1-6 & H1-8 of TMR1?
YES
Is there voltage across H1-2 & H1-3 of TMR1?
YES
Replace TMR1.
NO
Is there voltage to N.O. of door switch?
NO
Correct wiring between N.O. of door switch and H1-3 of TMR1.
YES
Continue at step 3 on previous page.
T063D
T063D
44
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
28. Will Not Start/Continue Running – EDC Control Note: Test conducted with vend price satisfied and start button pressed. Is there voltage at H4-4 on the EDC control to transformer neutral?
YES
Single and stacked units. Gas, electric and steam heat. Single and three phase supply.
Continued on next page.
Is there voltage at the input of the secondary fuse?
NO
Correct wiring between secondary fuse and transformer.
YES
NO
Is there power supplied to the unit?
NO
Plug unit in and run it.
Is there voltage to output side of secondary fuse?
NO
Replace secondary fuse.
YES YES Is there voltage to N.O. of door switch?
Is there voltage to input of primary fuse(s)?
NO
Correct wiring between primary fuse(s) and power supply.
YES
NO
Correct wiring between N.O. and output of secondary fuse.
YES
With door closed is there voltage to COM of door switch?
NO
Check for proper function of door switch replace if necessary.
YES
Is there voltage to output side of the primary fuse(s)?
NO
Replace primary fuse.
Is there voltage to N.O. of lint drawer switch?
YES
NO
Correct wiring between N.O. on lint drawer and COM on door switch.
YES Is there voltage across terminals 1 & 2 of transformer primary?
NO
Correct wiring between primary fuse and transformer.
Is there voltage to COM of lint drawer switch with lint panel closed?
NO
Check for proper operation replace if necessary.
YES YES
Is there voltage across terminals 2 & 3 of transformer secondary?
YES
NO
Replace transformer.
Is there voltage at H4-1 on the EDC control board?
NO
Correct wiring between H4-1 and COM of lint drawer switch.
YES
Replace EDC Control. T029D
T029D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
45
Electronic Control Troubleshooting
28. Will Not Start/Continue Running – EDC Control (continued) Note: Tests conducted with vend price satisfied and start button pressed. Is there voltage across terminals 1 & 4 of the fan motor?
Is there voltage on B terminal of motor control relay?
NO
Correct wiring between B and H4-4.
NO
Correct wiring between fan motor and motor control relay.
YES
YES Does the fan motor run?
NO
Replace fan motor.
Three phase. Refer to Note on next page Is the unit equipped with single phase or three phase power?
YES
Is unit equipped with single phase or three phase power supply?
Single phase
Is there voltage to terminal 5 of the motor control relay?
NO
Correct wiring between terminal 5 and power supply.
Three phase. Refer to Note on next page
Is there supply voltage to L2 & L3 of motor control relay?
YES
Single phase
NO
Correct wiring between L2, L3 and supply.
YES
Replace motor control relay.
YES Is there voltage to terminal 8 of motor control relay?
NO
Replace motor control relay. Is there voltage across terminals L2 & T2 and L3 & T3?
YES
NO Is there supply voltage to L1 and L2 of the motor control relay?
NO
Correct wiring between L1, L2 and power supply. Is there voltage at terminal 6 of motor control relay?
YES
NO
Correct wiring between terminal 6 of motor control relay and supply.
YES
Is there votlage across L1 & T1 and L2 & T2?
YES
Replace motor control relay.
Is there voltage at terminal 9 of motor control relay?
NO
Replace motor control relay.
NO YES Continued on next page. T030D
T030D
46
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
28. Will Not Start/Continue Running – EDC Control (continued)
Is there voltage across terminals 1 & 4 of cylinder motor?
NO
Correct wiring between cylinder motor and motor control relay.
YES
Does the cylinder motor run?
NO
Replace cylinder motor.
YES
Motors are operational.
Note: For high voltage three phase supply (380 volts or higher), the cylinder and fan motors are supplied by L1, L2, L3 through the motor relay terminals T1, T2, T3. Make the appropriate adjustments when doing voltage checks. T031D
T031D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
47
Electronic Control Troubleshooting
29. Will Not Start/Continue Running – OPL Microprocessor Control Gas, steam and electric heat. Single and three phase supply. Reference voltage to supply neutral. Is power supplied to unit?
NO
Connect supply and run unit.
YES
Is there voltage to output of secondary fuse?
NO
Replace secondary fuse.
YES
Is there voltage to input of primary fuse(s)?
NO
Correct wiring between primary fuse and supply.
YES
Is there voltage to N.O. terminal of door switch?
NO
Correct wiring between N.O. terminal of door switch and secondary fuse.
YES
Is there voltage to output of primary fuse(s)?
NO
Change primary fuse.
YES
With door closed is there voltage to COM of door switch?
NO
Check for proper operation, replace door switch if necessary.
YES
Is there voltage across terminals 1 & 2 on primary of transformer?
NO
Correct wiring between transformer and primary fuse.
YES
Is there voltage to N.O. of lint panel switch?
NO
Correct wiring between N.O. of lint panel switch and COM of door switch.
YES
Is there voltage across terminals 2 & 3 of transformer secondary?
NO
Replace transformer.
YES
Is there voltage to COM of lint panel switch with lint panel closed?
NO
Check for proper operation and replace lint panel switch if necessary.
YES Note: Reference voltage to transformer secondary neutral terminal 3.
Is there voltage to input of secondary fuse?
YES
NO
Correct wiring between secondary fuse and transformer.
Is there voltage at terminal 8 of OPL Micro?
NO
Correct wiring between terminal 8 of OPL Micro and COM of lint panel switch.
YES
Continued on next page. T099D
T099D
48
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
29. Will Not Start/Continue Running – OPL Microprocessor Control (continued) Tests conducted with cycle selected and start key pad activated. Is there voltage across terminals 1 & 4 of fan motor?
Is there voltage at terminal 7 on OPL Micro?
NO
Correct wiring between fan motor and motor control relay.
NO
Replace OPL Micro. YES
YES Is there voltage across terminals B & A of motor control relay for OM model and terminals 0 & 1 for RM models?
Does the fan motor run? NO
NO
Replace fan motor.
Correct wiring to motor control relay. YES
YES Does the unit have reversing capabilities? Is unit supplied with single phase or three phase power?
See cylinder rotation. Either forward or reverse.
YES
Single phase
NO
Three phase. Gas and steam. Refer to Note on next page.
Single phase
Reference voltage to supply neutral. Correct wiring Is there voltage to L1 NO between L1, L2 and and L2 of the motor power supply. control relay?
Does the unit have single phase or three phase supply?
Three phase. Gas and steam. Refer to Note on next page. Is there voltage to L2 and L3 on the motor control relay?
YES
Is there voltage to T1 and T2 of the motor control relay?
NO
Replace motor control relay.
Is there voltage at terminal 5 on the motor control relay for OM models and terminal 2 for RM models?
NO
Correct wiring between motor control relay and power supply.
Correct wiring between L2, L3 and power supply.
NO
Replace motor control relay.
YES Is there voltage to T2 and T3 on the motor control relay?
YES
NO
Is there voltage to terminal 6 of motor control relay?
Correct wiring between terminal 6 motor control relay and supply voltage.
NO
YES YES Is there voltage across terminals 5 & 8 of the motor control relay for OM models and terminals 2 & 4 for RM models?
NO
YES
Replace motor control relay.
Is there voltage across terminals 6 & 9 of motor control relay?
NO
YES
Replace motor control relay.
Continued on next page. TMB1824S
TMB1824S
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
49
Electronic Control Troubleshooting
29. Will Not Start/Continue Running – OPL Microprocessor Control (continued) Is there voltage across terminals 1 & 4 of the cylinder motor?
NO
Correct the wiring between the cylinder motor and control relay.
YES
Does the cylinder motor run?
NO
Replace cylinder motor.
YES
Unit operational.
NOTE: For three phase high voltage (380 volts or higher), the cylinder and fan motors are supplied L1, L2, L3 through the motor relay terminals T1, T2, T3. Make the appropriate voltage checks while doing trouble shooting. T009D
T009D
50
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
30. Will Not Run – Electric – Manual Timer With and without time delay boards. Single and stacked units. Single and three phase power supply.
Is there voltage at terminal C on the drying timer?
NO
Correct wiring between drying timer and lint panel switch.
NO
Is the unit equipped with a time delay board?
YES
YES NOTE: make sure drying timer is in the "on" position. Is there voltage at terminal B on the drying timer?
NO
Is there voltage across H1-6 & H1-8 on TMR1?
Replace drying timer.
NO
Correct wiring to TMR1.
NO
Check for proper operation of airflow switch.
YES
Replace time delay board.
YES YES
**
Is there voltage across terminals 7 and 8 of CR1 relay?
NO
Is there voltage across terminals H1-4 & H1-8 on TMR2?
Correct the wiring between CR1 relay and terminal B on drying timer.
YES
YES
** Is there voltage across terminal 3 and 5 of CR1 relay?
YES
Is there voltage across DOB contacts on TMR2?
Replace CR1 relay.
NO NO NOTE: This test to be made with push to start switch pressed in. Is there voltage across terminals 2A & 1A of push to start switch?
YES
** Is there voltage across terminals 7 & 8 of CR2 relay?
Replace push to start switch.
NO
Correct wiring between CR2 relay and airflow switch.
YES
NO NOTE: The N.O. contact is closed in the rest position due to the physical mounting of the switch. ** Is there voltage across COM and N.O. of the airflow switch?
YES
Is there voltage across terminals 5 & 3 on the CR2 relay?
Adjust the airflow switch or replace if inoperative.
YES
Replace CR2 relay.
NO
NO
CONTINUED ON NEXT PAGE.
YES
** Is there voltage across coils B & A of the motor control relay?
** Tested with the start switch pressed in.
NO
Correct wiring between motor control relay and airflow switch. T051D
T051D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
51
Electronic Control Troubleshooting
30. Will Not Run – Electric – Manual Timer (continued) Is there voltage across terminals 14 & 13 of motor control relay?
Three phase
Is this a single phase or three phase unit?
Single phase
** Is there voltage across terminal 7 & 4 of the motor control relay?
YES
Replace motor control relay.
NO
Correct wiring between L1 and power supply.
NO
YES
Replace motor control relay.
NO
Is there voltage to L1 of motor control relay?
YES
Is there voltage at terminal 5 on the motor control relay to supply neutral?
NO
Correct wiring between terminal 5 and supply voltage.
Is there voltage to L2 of motor control relay?
NO
Correct wiring between L2 and power supply.
YES YES
Is there voltage across terminals 5 & 3 of the motor control relay?
YES
Replace motor control relay.
Is there voltage across L1 to T1 and L2 to T2 on the motor control relay?
YES
Replace motor control relay.
NO NO
Is there voltage across terminals 1 & 4 of fan motor?
NO
Correct wiring between fan motor and contact 8 on the motor control relay.
YES
Note: Only for non time delay machines
Is there voltage across terminals 3 & 5 of the fan motor centrifugal switch with the fan motor running?
YES Replace fan motor.
NO Does the fan motor run?
NO
Replace the fan motor. Continued on next page.
YES
** Tested with the start switch pressed in.
TMB1825S
TMB1825S
52
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
30. Will Not Run – Electric – Manual Timer (continued)
Three phase.
Is unit single phase or three phase?
Is there voltage to L2 on motor control relay?
NO
Correct wiring between terminal 6 and power supply.
Is there voltage to L3 on motor control relay?
YES
Is there voltage across terminal 6 & 9 of the motor control relay?
NO
Correct wiring between motor control relay and supply.
YES
YES
Replace motor control relay.
NO
Is there voltage at terminals 1 & 4 of the cylinder motor?
Correct wiring between motor control relay and supply.
YES
Single phase.
Is there voltage to terminal 6 on the motor control relay?
NO
Is there voltage across L2 to T2 and L3 to T3 on the motor control relay?
YES
Replace motor control relay.
NO
NO
Correct wiring between cylinder motor and contact 9 on the motor control relay.
YES
Does the cylinder motor run?
NO
Replace the cylinder motor.
YES
The cylinder and fan motors are operational.
T053D
T053D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
53
Electronic Control Troubleshooting
31. Will Not Run – Electric – Rotary Coin Drop Single and Stack with and without time delay. Single and three phase power. ** Is there voltage across terminals 7 & 8 of CR2 relay?
** Tested with vend price satisfied and with start switch pressed in.
**
Is there voltage across terminals 2A & 1A of push to start switch?
YES
Replace push to start switch.
NO
Correct wiring between CR2 relay and airflow switch.
YES
** Is there voltage across terminals 5 & 3 on the CR2 relay?
NO Note: Reference voltage to transformer neutral. Is there voltage to COM of the airflow switch?
NO
Correct wiring between COM of airflow switch and 1A on start switch.
YES
NO
** Is there voltage across the coil of the motor control relay?
YES NOTE: The N.O. contact is closed in the rest position due to the physical mounting of the switch. ** Is there voltage across COM and N.O. of the airflow switch?
YES
Replace inoperative switch or correct airflow vane operation.
Replace CR2 relay.
NO
Correct wiring between motor control relay and airflow switch.
YES
Is unit single phase or three phase?
Three phase Refer to note.
Continued on next page COLUMN 2.
NO Single phase
NO
Is the unit equipped with a time delay board?
** Is there voltage across terminal 7 & 4 of the motor control relay?
YES
Replace motor control relay.
YES
NO ** Is there voltage across terminals H1-4 & H1-8 on TMR2?
NO
Check for proper operation of airflow switch and check wiring.
Is there voltage at terminal 5 on the motor control relay?
NO
Correct wiring between terminal 5 and supply voltage.
YES YES ** Is there voltage across DOB contacts on TMR2?
YES
Replace time delay board.
Continued on next page COLUMN 1.
NO ** Tested with the start switch pressed in.
T072D
T072D
54
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
31. Will Not Run – Electric – Rotary Coin Drop (continued) COLUMN 2
COLUMN 1
Is there voltage across terminal 5 & 8 of the motor control relay?
YES
Is there voltage across terminal 14 & 13 of motor control relay?
Replace motor control relay.
Replace motor control relay.
NO
Correct wiring between L1, L2 and supply.
NO
Replace motor control relay.
NO
NO
Is there voltage across terminals 1 & 4 of fan motor?
YES
Correct wiring between fan motor and contact 8 on the motor control relay.
NO
Is there voltage to L1 & L2 terminals on motor control relay?
YES YES
YES
Does the fan motor run?
NO
Is there voltage to T1 & T2 terminals on motor control relay?
Replace the fan motor.
YES For units without time delay boards.
Is there voltage across terminals 3 & 5 of the fan motor centrifugal switch with the fan motor running?
YES
Replace fan motor.
NO
Is the machine supplied with single phase or three phase power?
NOTE: For Hi voltage three phase supply (380volts or higher), the cylinder and fan motor are supplied L1, L2, L3 through the motor relay terminals T1, T2, T3. Make the appropriate adjustments when doing trouble shooting.
Is there voltage to L2 & L3 terminals on motor control relay? Three phase Refer to Note.
NO
Correct wiring between supply and L2 & L3 terminals.
YES
Is there voltage across L2 to T2 and L3 to T3?
YES
Replace motor control relay.
NO
Replace cylinder motor.
Single phase NO
Is there voltage to terminal 6 on the motor control relay?
YES
Continued on next page COLUMN 1.
NO
Correct wiring between terminal 6 and power supply.
Does the cylinder motor run?
YES CYLINDER AND FAN MOTORS ARE OPERATIONAL.
T073D
T073D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
55
Electronic Control Troubleshooting
31. Will Not Run – Electric – Rotary Coin Drop (continued) COLUMN 1
Is there voltage across terminals 6 & 9 of motor control relay?
YES
Replace motor control relay.
NO
Is there voltage at terminals 1 & 4 of the cylinder motor?
NO
Correct wiring between cylinder motor and contact 9 on the motor control relay.
YES
Does the cylinder motor run?
NO
Replace the cylinder motor.
YES
The cylinder and fan motors are operational. T074D
T074D
56
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
32. Will Not Run – Gas – Manual Timer No motor run (run circuit). Single and stacked units with and without time delay boards.
Is there voltage at terminal c on the drying timer?
NO
Correct wiring between drying timer and lint panel switch.
NO
YES
Is the unit equipped with a time delay board?
YES NOTE: make sure drying timer is in the “on” position.
Is there voltage at terminal b on the drying timer?
NO
Is there voltage across H1-6 & H1-8 on TMR1?
Replace drying timer.
NO
Correct wiring to TMR1.
NO
Check for proper operation of airflow switch.
YES
Replace time delay board.
YES
YES
**
Is there voltage across terminals 7 and 8 of CR1 relay?
NO
Is there voltage across terminals H1-4 & H1-8 on TMR2?
Correct the wiring between CR1 relay and terminal b on drying timer.
YES
YES
** Is there voltage across terminal 3 and 5 of CR1 relay?
YES
Is there voltage across DOB contacts on TMR2?
Replace CR1 relay.
NO NO NOTE: This test to be made with push to start switch pressed in. Is there voltage across terminals 2A & 1A of push to start switch?
YES
** Is there voltage across terminals 7 & 8 of CR2 relay?
Replace push to start switch.
NO
Correct wiring between CR2 relay and airflow switch.
YES
NO NOTE: The N.O. contact is closed in the rest position due to the physical mounting of the switch. ** Is there voltage across COM and N.O. of the airflow switch?
YES
Is there voltage across terminals 5 & 3 on the CR2 relay?
Adjust the airflow switch or replace if inoperative.
YES
Replace CR2 relay.
NO
NO
**
CONTINUED ON NEXT PAGE.
YES
** Is there voltage across coils B & A of the motor control relay?
NO
Correct wiring between motor control relay and airflow switch.
Tested with the start switch pressed in. T042D
T042D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
57
Electronic Control Troubleshooting
32. Will Not Run – Gas – Manual Timer (continued)
** Is there voltage across terminal 7 & 4 of the motor control relay?
YES
NO
Does the fan motor run?
NO
Replace the fan motor.
YES Note: Only for non time delay machines
Replace motor control relay.
Is there voltage across terminals 3 & 5 of the fan motor centrifugal switch with the fan motor running?
YES
Replace fan motor.
NO
Is there voltage at terminal 5 on the motor control relay to to supply neutral?
NO
Correct wiring between terminal 5 and supply voltage.
Is there voltage to terminal 6 on the motor control relay and supply neutral?
NO
Correct wiring between terminal 6 and power supply.
YES YES
Is there voltage across terminal 5 & 8 of the motor control relay?
YES
Replace motor control relay.
Is there voltage across terminal 6 & 9 of the motor control relay?
YES
Replace motor control relay.
NO NO
Is there voltage across terminals 1 & 4 of fan motor?
NO
Correct wiring between fan motor and contact 8 on the motor control relay.
Is there voltage at terminals 1 & 4 of the cylinder motor?
NO
Correct wiring between cylinder motor and contact 9 on the motor control relay.
YES
YES
Does the cylinder motor run?
NO
Replace the cylinder motor.
YES
**
Tested with the start switch pressed in. The cylinder and fan motors are operational. T043D
T043D
58
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
33. Will Not Run – Gas – Rotary Coin Drop Single and stack with and without time delay.
**
** Tested with start switch pressed in. ** Is there voltage across terminals 2A & 1A of push to start switch?
YES
Replace push to start switch.
Is there voltage across DOB contacts (H1-4 and H1-5) on TMR2?
YES
Replace time delay board.
NO NO Note: Reference voltage to transformer neutral. Is there voltage to COM of the airflow switch?
NO
Correct wiring between COM of airflow switch and 1A on start switch.
YES NOTE: The N.O. contact is closed in the rest position due to the physical mounting of the switch.
** Is there voltage across terminals 7 & 8 of CR2 relay?
NO
Correct wiring between CR2 relay and airflow switch.
YES
** Is there voltage across terminals 5 & 3 on the CR2 relay?
YES
Replace CR2 relay.
** Is there voltage across COM and N.O. of the airflow switch?
YES
Adjust the airflow switch or replace if inoperative.
NO
** Is there voltage across coils B & A of the motor control relay?
NO
NO
Correct wiring between motor control relay and airflow switch.
YES Is the unit equipped with a time delay board?
NO ** Is there voltage across terminal 7 & 4 of the motor control relay?
YES
YES
Replace motor control relay.
NO Is there voltage across H1-6 & H1-8 on TMR1?
NO
Correct wiring to TMR1. Is there voltage at terminal 5 on the motor control relay?
YES
Correct wiring between terminal 5 and supply voltage.
YES
** Is there voltage across terminals H1-4 & H1-8 on TMR2?
NO
NO
Check for proper operation of airflow switch and check wiring.
CONTINUED ON NEXT PAGE.
YES
** Tested with the start switch pressed in.
T088D
T088D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
59
Electronic Control Troubleshooting
33. Will Not Run – Gas – Rotary Coin Drop (continued)
Is there voltage across terminal 5 & 8 of the motor control relay?
YES
Replace motor control relay.
Is there voltage at terminals 1 & 4 of the cylinder motor?
NO
Correct wiring between cylinder motor and contact 9 on the motor control relay.
YES
NO
Is there voltage across terminals 1 & 4 of fan motor?
NO
Correct wiring between fan motor and contact 8 on the motor control relay.
Does the cylinder motor run?
NO
Replace the cylinder motor.
YES YES
Does the fan motor run?
NO
Replace the fan motor.
YES
Replace fan motor.
The cylinder and fan motors are operational.
YES
Is there voltage across terminals 3 & 5 of the fan motor centrifugal switch with the fan motor running?
NO
Is there voltage to terminal 6 on the motor control relay?
NO
Correct wiring between terminal 6 and power supply.
YES
Is there voltage across terminal 6 & 9 of the motor control relay?
YES
Replace motor control relay.
NO
** Tested with the start switch pressed in.
T089D
T089D
60
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
34. Will Not Run – Steam – Manual Timer Single and stacked units with and without time delay board.
NO Is there voltage at terminal C on the drying timer?
NO
Correct wiring between drying timer and lint panel switch.
Is the unit equipped with a time delay board?
YES YES NOTE: Make sure drying timer is in the "on" position. Is there voltage at terminal B on the drying timer?
NO
Is there voltage across H1-6 & H1-8 on TMR1?
NO
Correct wiring to TMR1.
NO
Check for proper operation of airflow switch.
Replace drying timer. YES
YES **
Is there voltage across terminals 7 and 8 of CR1 relay?
NO
Is there voltage across terminals H1-4 & H1-8 on TMR2?
Correct the wiring between CR1 relay and terminal B on drying timer.
YES YES
** Is there voltage across terminal 3 and 5 of CR1 relay?
YES
Is there voltage across DOB contacts on TMR2?
Replace CR1 relay.
YES
Replace time delay board.
NO NO
NOTE: This test to be made with push to start switch pressed in. Is there voltage across terminals 2A & 1A of push to start switch?
YES
** Is there voltage across terminals 7 & 8 of CR2 relay?
Replace push to start switch.
NO
Correct wiring between CR2 relay and airflow switch.
NO YES NOTE: The N.O. contact is closed in the rest position due to the physical mounting of the switch. ** Is there voltage across COM and N.O. of the airflow switch?
YES
Is there voltage across terminals 5 & 3 on the CR2 relay?
Adjust the airflow switch or replace if inoperative.
YES
Replace CR2 relay. .
NO NO
CONTINUED ON NEXT PAGE. **
YES
** Is there voltage across B & A of the motor control relay?
NO
Tested with the start switch pressed in.
Correct wiring between motor control relay and airflow switch. T017D
T017D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
61
Electronic Control Troubleshooting
34. Will Not Run – Steam – Manual Timer (continued)
** Is there voltage across terminal 7 & 4 of the motor control relay?
YES
NO
Does the fan motor run?
Replace the fan motor.
YES
NO
Note: Only for non time delay machines
Replace motor control relay.
Is there voltage across terminals 3 & 5 of the fan motor centrifugal switch with the fan motor running?
YES
Replace fan motor.
NO
Is there voltage at terminal 5 on the motor control relay to to supply neutral?
NO
Correct wiring between terminal 5 and supply voltage.
Is there voltage to terminal 6 on the motor control relay and supply neutral?
NO
Correct wiring between terminal 6 and power supply.
YES YES
Is there voltage across terminal 5 & 8 of the motor control relay?
YES
Replace motor control relay.
Is there voltage across terminal 6 & 9 of the motor control relay?
YES
Replace motor control relay.
NO NO
Is there voltage across terminals 1 & 4 of fan motor?
NO
Correct wiring between fan motor and contact 8 on the motor control relay.
Is there voltage at terminals 1 & 4 of the cylinder motor?
NO
Correct wiring between cylinder motor and contact 9 on the motor control relay.
YES
YES
Does the cylinder motor run?
NO
Replace the cylinder motor.
YES
**
Tested with the start switch pressed in. The cylinder and fan motors are operational.
T018D
T018D
62
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
35. Will Not Run – Steam – Rotary Coin Drop Single and stack with and without time delay. **
** Tested with start switch pressed in and vend satisfied.
**
Is there voltage across terminals 2A & 1A of push to start switch?
YES
Is there voltage across DOB contacts on TMR2?
YES
Replace time delay board.
Replace push to start switch.
NO NO Note: Reference voltage to transformer neutral. Is there voltage to COM of the airflow switch?
NO
Correct wiring between COM of airflow switch and 1A on start switch.
** Is there voltage across terminals 7 & 8 of CR2 relay?
NO
Correct wiring between CR2 relay and airflow switch.
YES YES NOTE: The N.O. contact is closed in the rest position due to the physical mounting of the switch. ** Is there voltage across COM and N.O. of the airflow switch?
YES
Adjust the airflow switch or replace if inoperative.
** Is there voltage across terminals 5 & 3 on the CR2 relay?
Replace CR2 relay.
NO
** Is there voltage across B & A of the motor control relay?
NO
YES
NO
Correct wiring between motor control relay and airflow switch.
YES Is the unit equipped with a time delay board?
NO ** Is there voltage across terminal 7 & 4 of the motor control relay?
YES
YES
Replace motor control relay.
NO Is there voltage across H1-6 & H1-8 on TMR1?
NO
Correct wiring to TMR1.
Is there voltage at terminal 5 on the motor control relay?
YES
** Is there voltage across terminals H1-4 & H1-8 on TMR2?
NO
Correct wiring between terminal 5 and supply voltage.
YES NO
Check for proper operation of airflow switch and check wiring.
CONTINUED ON NEXT PAGE. YES
**
Tested with the start switch pressed in.
T064D
T064D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
63
Electronic Control Troubleshooting
35. Will Not Run – Steam – Rotary Coin Drop (continued)
Is there voltage across terminal 5 & 8 of the motor control relay?
YES
Replace motor control relay.
Is there voltage at terminals 1 & 4 of the cylinder motor?
NO
Correct wiring between cylinder motor and contact 9 on the motor control relay.
YES
NO
Is there voltage across terminals 1 & 4 of fan motor?
NO
Correct wiring between fan motor and contact 8 on the motor control relay.
Does the cylinder motor run?
NO
Replace the cylinder motor.
YES YES
NO
Does the fan motor run?
Replace the fan motor.
The cylinder and fan motors are operational.
YES Only for units without time delay boards.
Is there voltage across terminals 3 & 5 of the fan motor centrifugal switch with the fan motor running?
YES
Replace fan motor.
NO
Is there voltage to terminal 6 on the motor control relay?
NO
Correct wiring between terminal 6 and power supply.
YES
Is there voltage across terminal 6 & 9 of the motor control relay?
YES
Replace motor control relay.
NO
** Tested with the start switch pressed in.
T065D
T065D
64
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
36. Will Not Heat – Electric – Manual Timer With and without time delay board. Single and stacked units. Single and three phase power supply. NOTE: The following tests are conducted with the heat timer in the "ON" position with the machine running and calling for heat. Voltage checks are referenced to transformer neutral.
Is there voltage across terminals 1 & 6 of the temp control bd?
Is there voltage at airflow switch N.C. terminal to transformer neutral?
NO
Replace inoperative switch or correct airflow vane operation.
NO
Correct wiring between airflow switch and terminal 6 on CR1.
YES
YES
YES
NO
Is there voltage at terminal 6 on CR1 to transformer neutral?
Is there voltage across terminals 5 & 6 of the temp control bd?
YES NO
Is the thermistor shorted or open?
YES
Is there voltage from terminal 4 on CR1 to transformer neutral?
Replace thermistor.
NO
Replace CR1.
YES NO
YES Is temperature selection switch shorted or open?
YES
Is unit equipped with time delay board?
Replace selection switch. NO
NO Replace the temperature control board.
Is there voltage to terminal 3 of fan motor?
NO
Correct wiring between fan motor terminal 3 and CR1 terminal 4.
Is there voltage from terminal 6 on CR2 to transformer neutral?
NO
Correct wiring between terminal 6 on CR2 to terminal 4 on CR1.
YES YES
CONTINUED ON NEXT PAGE
Is there voltage from terminal 4 on CR2 to transformer neutral? Is there voltage at terminal 3 & 5 of fan motor?
NO
NO
Replace CR2.
Replace fan motor. YES
YES Correct wiring between motor terminal 5 and temp control board terminal 1.
Correct wiring between CR2 terminal 4 & terminal 1 on temp control board.
T054D
T054D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
65
Electronic Control Troubleshooting
36. Will Not Heat – Electric – Manual Timer (continued) Note: Voltage checks are referenced to transformer neutral.
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and temp control board.
NO
Replace elements.
YES
YES
Is there voltage to the output side of the cabinet limit?
Do the elements produce heat?
NO
Replace the cabinet limit.
NO
Correct wiring between stove limit and cabinet limit.
NO
Replace the stove limit.
UNIT OPERATIONAL
YES
Is there voltage to the input side of the stove limit?
YES
Is there voltage to the output side of the stove limit?
YES
Is there voltage across HC1 & HC2 element contactor coils?
NO
Correct wiring between element contactor coils and stove limit.
YES
Is there voltage across the elements?
NO
Check wiring between elements, contactors and supply. Correct if necessary.
YES T055D
T055D
66
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
37. Will Not Heat – Electric Single and stacked units with single and three phase supply.
Note: Tests are conducted with unit running and calling for heat. All voltage checks are referenced to transformer neutral.
Is there voltage on FS-2 of EDC control?
NO
Correct wiring between FS-2 and COM of lint drawer.
YES
NO
Correct wiring between terminal 3 of fan motor centrifugal switch and terminal 4 of motor control relay.
YES Replace EDC control.
Replace thermistor.
NO
Is there voltage on FS-1 of EDC control?
Is there voltage on terminal 3 of fan motor centrifugal switch?
Is there voltage at terminal 5 of fan motor centrifugal switch?
NO
Is the thermistor operational?
YES
Is there voltage on COM of airflow switch?
NO
NO Replace fan motor.
YES
Correct wiring between COM of airflow switch and FS-1 of EDC control.
YES
YES
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and terminal 5 of fan motor centrifugal switch.
YES
Is there voltage at N.C. terminal of airflow switch?
NO
Check for proper function of airflow switch and replace if necessary.
YES
Is there voltage at the output of the cabinet limit?
NO
Replace cabinet limit.
YES
Is there voltage on terminal 7 of motor control relay?
NO
Correct wiring between terminal 7 on motor control relay and N.C. terminal on airflow switch.
Is there voltage to the input side of the stove limit?
NO
Correct wiring between stove limit and cabinet limit.
YES
YES
Is there voltage at terminal 4 of motor control relay?
NO
Replace motor control relay.
Continued on next page.
YES T034D
T034D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
67
Electronic Control Troubleshooting
37. Will Not Heat – Electric (continued)
Is there voltage to the output side of the stove limit?
NO
Replace the stove limit.
YES
Is there voltage across coils HC1 & HC2?
NO
Correct wiring to the coils of HC1 and HC2.
YES
Is there voltage across the heating elements?
NO
Correct wiring between elements and supply. Replace HC1 and or HC2 if necessary
YES
Do the elements produce heat?
NO
Replace elements.
YES
Unit operational. T035D
T035D
68
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
38. Will Not Heat – Electric – Rotary Coin Drop (With and Without Time Delay Board) Single and stacked tumblers with and without time delay. Single and three phase units.
Is there voltage across across terminals 1 & 6 of the temp control board?
Is there voltage at airflow switch N.C. terminal to transformer neutral?
NO
Is there voltage across across terminals 5 & 6 of the temp control board?
Is there voltage at COM on switch B to transformer neutral?
NO
Correct wiring between airflow switch and COM on switch B.
YES
NO
Is the thermistor shorted or open?
Adjust the airflow switch or replace if inoperative.
YES
YES
YES
NO
YES
Replace thermistor.
Is there voltage from N.C. on switch B to transformer neutral?
NO
Replace switch B.
NO YES Is temperature selection switch shorted or open?
YES
Replace selection switch. YES
NO Replace the temperature control board.
Is there voltage on terminal 3 of fan motor to transformer neutral?
Is the unit equipped with a time delay board?
NO
NO
Correct wiring between terminal 3 of fan motor and N.C. terminal on switch B.
Is there voltage from terminal 6 on CR2 to transformer neutral?
NO
Correct wiring between terminal 6 on CR2 to terminal N.C. on switch B.
YES
YES
With fan motor running is there voltage from terminal 5 to transformer neutral?
NO
Replace fan motor.
YES
Is there voltage on terminal 1 of temp board to transformer neutral? YES
CONTINUED ON NEXT PAGE
Is there voltage from terminal 4 on CR2 to transformer neutral?
NO
Replace CR2.
YES
NO
Correct wiring between terminal 1 of temp board to terminal 5 of fan motor.
Correct wiring between terminal 4 on CR2 & terminal 1 on temp control board.
Power supply to temp control board is good. T077D
T077D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
69
Electronic Control Troubleshooting
38. Will Not Heat – Electric – Rotary Coin Drop (With and Without Time Delay Board) (continued) Note: Voltage checks are referenced to transformer neutral.
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and temp control board.
NO
Replace elements.
YES
YES
Is there voltage to the output side of the cabinet limit?
Do the elements produce heat?
NO
Replace the cabinet limit.
NO
Correct wiring between stove limit and cabinet limit.
NO
Replace the stove limit.
NO
Correct the wiring to the coils.
UNIT OPERATIONAL
YES
Is there voltage to the input side of the stove limit?
YES
Is there voltage to the output side of the stove limit?
YES
Is there voltage across the coils of HC1 & HC2?
YES
Is there voltage across the elements?
NO
Check the wiring between elements, contactors and supply. Correct if necessary.
YES T078D
T078D
70
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
39. Will Not Heat – Electric/Gas – OPL Microprocessor Note: Testing conducted with unit running and calling for heat.
Single and three phase supply.
Reference voltage to transformer neutral terminal 3. Is there voltage at terminal 5 on OPL Micro?
NO
YES
Continued on next page column 2.
Test conducted with unit running and calling for heat.
Is the thermister operating properly?
NO
Replace thermister.
Is there voltage across terminals 2 & 3 of transformer secondary?
NO
Replace transformer.
YES Note: Reference voltage to transformer secondary neutral terminal 3.
Is there voltage to input of secondary fuse?
NO
Correct wiring between secondary fuse and transformer.
YES
YES Reference voltage to supply neutral.
Is power supplied to unit?
NO
Connect supply and run unit.
NO
Replace secondary fuse.
YES
YES
Is there voltage to input of primary fuse(s)?
NO
Correct wiring between primary fuse and supply.
Is there voltage to N.O. terminal of door switch?
NO
Correct wiring between N.O. terminal of door switch and secondary fuse.
YES
YES
Is there voltage to output of primary fuse(s)?
NO
Change primary fuse.
With door closed is there voltage to COM of door switch?
NO
Check for proper operation, replace door switch if necessary.
YES
YES
Is there voltage across terminals 1 & 2 on primary of transformer?
YES
Is there voltage to output of secondary fuse?
NO
Correct wiring between transformer and primary fuse.
Is there voltage to N.O. of lint panel switch?
NO
Correct wiring between N.O. of lint panel switch and COM of door switch.
YES
Continued on next page Column 1. T010D
T010D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
71
Electronic Control Troubleshooting
39. Will Not Heat – Electric/Gas – OPL Microprocessor Column 1
Column 2
Is there voltage to COM of lint panel switch with lint panel closed?
NO
Check for proper operation and replace lint panel switch if necessary.
The following tests are conducted with the unit running and calling for heat.
Is there voltage at COM of airflow switch?
YES
NO
Correct wiring between COM & OPL Micro.
YES
Is there voltage at terminal 8 of OPL Micro?
NO
Correct wiring between terminal 8 of OPL Micro and COM of lint panel switch.
Is there voltage at N.C. terminal of airflow switch?
YES
NO
Check for proper operation and replace if necessary.
YES
Is there voltage to terminal 13 of OPL Micro?
NO
Three phase Replace OPL Micro.
Is the unit supplied with single phase or three phase power?
single phase
YES
Is there voltage at terminal 6 of OPL Micro?
NO
Correct wiring between terminal 6 & 13 on OPL Micro.
YES
Is there voltage at terminal 7 of motor control relay for OM models or terminal 8 for RM models?
NO
Correct wiring between terminal 7/8 of motor control relay and N.C. of airflow switch.
YES Replace OPL Micro. Is there voltage at terminal 4 of motor control relay for OM models or terminal 6 for RM models?
Is there voltage to terminal 14 on motor control relay?
NO
YES
Correct wiring between terminal 14 on motor control relay and N.C. terminal of airflow switch.
NO
Replace motor control relay.
YES
Is there voltage at terminal 3 of fan motor centrifugal switch?
NO
Correct wiring between fan motor centrifugal switch and motor control relay.
YES
Is there voltage across terminals 14 & 13 of motor control relay?
NO
Is there voltage at terminal 5 of fan motor centrifugal switch?
NO
Replace fan motor.
YES YES Replace motor control relay.
Continued on next page. T011D
T011D
72
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
39. Will Not Heat – Electric/Gas – OPL Microprocessor (continued) Continued from column 2 of previous page.
Is there voltage to the input of the cabinet limit?
NO
Correct wiring between cabinet limit and terminal 5 of fan motor centrifugal switch.
Is there voltage to terminal 1 of ICM board?
NO
Replace ICM board.
YES YES
Is there voltage across the coils of the gas valve? Is there voltage to output of cabinet limit?
NO
NO
Correct wiring to gas valve coils.
NO
Replace the coils or complete gas valve.
Replace cabinet limit. YES
YES Is there gas flow through the valve?
Is there voltage to input of stove limit?
NO
Correct wiring between stove limit and cabinet limit.
YES
YES
Is there a flame?
YES
Unit is operational.
NO Is there voltage to the output side of the stove limit?
NO
Replace stove limit.
Does the ignitor spark?
YES
Check gas pressures and adjust if necessary.
YES
NO
Is the unit equipped with gas heat or electric heat?
Replace igniter or ignition cable.
ELECTRIC
GAS Is there voltage across HC1 & HC2 coils?
Is there voltage to terminal 2 of ICM board?
NO
Correct wiring between ICM board and stove limit.
NO
Correct the wiring to the HC1 and/or HC2 coils.
YES
Do the elements produce heat?
YES
UNIT OPERATIONAL.
NO
Correct wiring between supply, contacts and elements. Replace contactors and/or elements if necessary.
YES T012D
T012D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
73
Electronic Control Troubleshooting
40. Will Not Heat – Gas – EDC Models Single and stacked units.
Note: Tests are conducted with unit running and calling for heat. All voltage checks are referenced to transformer neutral.
Is there voltage on FS-2 of EDC control?
Correct wiring between FS-2 and COM of lint panel switch.
NO
YES
NO
Correct wiring between terminal 3 of fan motor centrifugal switch and terminal 4 of motor control relay.
YES Replace EDC control.
Replace thermistor.
Is there voltage on FS-1 of EDC control?
Is there voltage on terminal 3 of fan motor centrifugal switch?
NO
NO
Is there voltage across terminals 3 & 5 of fan motor centrifugal switch?
Is the thermistor operational?
YES
Is there voltage on COM of airflow switch?
NO
YES
Replace fan motor.
YES
Correct wiring between COM of airflow switch and FS-1 of EDC control.
NO
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and terminal 5 of fan motor centrifugal switch.
YES
YES
Is there voltage across COM & N.C. terminal of airflow switch?
YES
Check for proper function of airflow switch and replace if necessary.
Is there voltage across cabinet limit?
YES
Replace cabinet limit.
NO
Correct wiring between stove limit and cabinet limit.
NO
NO
Is there voltage on terminal 7 of motor control relay?
NO
Correct wiring between terminal 7 on motor control relay and N.C. terminal on airflow switch.
YES
Is there voltage to the input side of the stove limit?
YES
Is there voltage across terminals 7 & 4 of motor control relay?
YES
Replace motor control relay.
Continued on next page.
NO
TMB1833S
TMB1833S
74
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
40. Will Not Heat – Gas – EDC Models (continued)
Is there voltage to the output side of the stove limit?
NO
Replace the stove limit.
YES
Is there a flame?
YES
Unit operational.
NO
Is there voltage to terminal 2 of the ICM board?
NO
Correct wiring between terminal 2 of ICM board and stove limit.
YES
Is there voltage at terminal 1 of ICM board?
NO
Replace ICM board.
YES
Is there voltage across the coils of the gas valve?
NO
Correct wiring between gas valve and ICM board.
NO
Replace gas valve coils or complete gas valve.
NO
Replace high voltage ignition cable or igniter.
YES
Is there gas flow through the gas valve?
YES
Does the igniter spark?
YES T033D
T033D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
75
Electronic Control Troubleshooting
41. Will Not Heat – Gas – Manual Timer NOTE: The following tests are conducted with the Heat Timer in the "ON" position with the machine running and calling for heat. Voltage checks are referenced to transformer neutral.
Is there voltage across terminals 1 & 6 of the temp control bd?
Single and stacked units with and without time delay boards.
Is there voltage at airlow switch N.C. terminal to transformer neutral?
NO
Replace inoperative switch or correct airflow vane operation.
YES
YES
YES
NO
Is there voltage at terminal 6 on CR1 to transformer neutral?
Is there voltage across terminals 5 & 6 of the temp control bd?
NO
Correct wiring between airlow switch and terminal 6 on CR1.
YES NO Is there voltage from terminal 4 on CR1 to transformer neutral? Is the thermistor shorted or open?
YES
Replace thermistor.
NO
Is the temperature selection switch shorted or open?
Is there voltage from terminal 6 on CR2 to transformer neutral?
Is there voltage to terminal 3 of fan motor?
NO
Correct wiring between fan motor terminal 3 and CR1 terminal 4.
Is there voltage across terminal 3 & 5 of fan motor?
YES
NO
Correct wiring between terminal 6 on CR2 to terminal 4 on CR1.
YES
Is there voltage from terminal 4 on CR2 to transformer neutral?
YES
CONTINUED ON NEXT PAGE
Is unit equipped with time delay board?
NO
Replace selection switch.
NO
Replace the temperature control board.
Replace CR1.
YES
YES
YES
NO
NO
Replace CR2.
YES Replace fan motor.
Correct wiring between CR2 terminal 4 & terminal 1 on temp control board.
NO Correct wiring between motor terminal 5 and temp control board terminal 1. T044D
T044D
76
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
41. Will Not Heat – Gas – Manual Timer (continued) Note: Voltage checks are referenced to transformer neutral.
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and temp control board.
Is there voltage across the coils of the gas valve?
NO
Is there gas flow through the gas valve?
Replace the cabinet limit.
NO
Correct wiring between stove limit and cabinet limit.
Does the igniter spark?
YES
Is there voltage to the output side of the stove limit?
NO
Replace gas valve or gas valve coils.
NO
Replace high voltage cable or igniter.
YES
YES
Is there voltage to the input side of the stove limit?
Correct wiring between gas valve and ICM board.
YES
YES
Is there voltage to the output side of the cabinet limit?
NO
YES
NO
Replace the stove limit.
NO
Is there a flame?
YES
YES
UNIT OPERATIONAL Is there voltage across terminals 2 & 3 of ICM board?
NO
Correct wiring between ICM board and stove limit.
YES
Is there voltage across terminals 1 & 3 of the ICM board?
NO
Replace ICM board
YES TMB1834S
TMB1834S
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
77
Electronic Control Troubleshooting
42. Will Not Heat – Gas – Rotary Coin Drop Single and stacked tumblers with and without time delay.
Is there voltage across terminals 1 & 6 of the temp control bd?
Is there voltage at airflow switch N.C. terminal to transformer neutral?
NO
Is there voltage across terminals 5 & 6 of the temp control bd?
Is there voltage at COM on switch B to transformer neutral?
NO
Correct wiring between airflow switch and COM on switch B.
YES
NO
Is the thermistor shorted or open?
Replace inoperative switch or correct airflow vane operation.
YES
YES
YES
NO
YES
Replace thermistor.
Is there voltage from N.C. on switch B to transformer neutral?
NO
Replace switch B.
NO YES Is temperature selection switch shorted or open?
YES
Replace selection switch. YES
NO Replace the temperature control board.
Is there voltage on terminal 3 of fan motor to transformer neutral?
Is the unit equipped with a time delay board?
NO
NO
Correct wiring between terminal 3 of fan motor and N.C. terminal on switch B.
Is there voltage from terminal 6 on CR2 to transformer neutral?
NO
Correct wiring between terminal 6 on CR2 to terminal N.C. on switch B.
YES
YES
With fan motor running is there voltage from terminal 5 to transformer neutral?
NO
Replace fan motor.
YES
Is there voltage on terminal 1 of temp board to transformer neutral? YES
CONTINUED ON NEXT PAGE
Is there voltage from terminal 4 on CR2 to transformer neutral?
NO
Replace CR2.
YES
NO
Correct wiring between terminal 1 of temp board to terminal 5 of fan motor.
Correct wiring between terminal 4 on CR2 & terminal 1 on temp control board.
Power supply to temp control board is good. T090D
T090D
78
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
42. Will Not Heat – Gas – Rotary Coin Drop (continued) Note: Voltage checks are referenced to transformer neutral.
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and temp control board.
Is there voltage across the coils of the gas valve?
YES
Is there voltage to the output side of the cabinet limit?
NO
Replace the cabinet limit.
Is there gas flow through the gas valve?
NO
Correct wiring between stove limit and cabinet limit.
Replace gas valve coils or complete gas valve.
Does the igniter spark?
NO
Replace high voltage ignition cable or igniter.
YES
NO
Replace the stove limit.
YES
Is there voltage across terminals 2 & 3 of the ICM board?
NO
YES
YES
Is there voltage to the output side of the stove limit?
Correct wiring between gas valve and ICM board.
YES
YES
Is there voltage to the input side of the stove limit?
NO
NO
Is there a flame?
YES
NO
Correct wiring between ICM board and stove limit or neutral.
UNIT OPERATIONAL
YES
Is there voltage across terminals 1 & 3 of the ICM board?
NO
Replace the ICM board.
YES T091D
T091D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
79
Electronic Control Troubleshooting
43. Will Not Heat – Steam – EDC Models Single and stacked units.
Note: Tests are conducted with unit running and calling for heat. All voltage checks are referenced to transformer neutral.
Is there voltage on FS-2 of EDC control?
Correct wiring between FS-2 and COM of lint drawer.
NO
YES
NO
Correct wiring between terminal 3 of fan motor centrifugal switch and terminal 4 of motor control relay.
YES Replace EDC control.
Replace thermistor.
Is there voltage on FS-1 of EDC control?
Is there voltage on terminal 3 of fan motor centrifugal switch?
NO
NO
Is there voltage across terminals 3 & 5 of fan motor centrifugal switch?
Is the thermistor operational?
YES
Is there voltage on COM of airflow switch?
NO
NO
Correct wiring between COM of airflow switch and FS-1 of EDC control.
YES
Check for proper function of airflow switch and replace if necessary.
NO
Correct wiring between cabinet limit and terminal 5 of fan motor centrifugal switch.
Is there voltage across cabinet limit?
YES
Replace cabinet limit.
NO
Correct wiring between stove limit and cabinet limit.
NO
NO
Correct wiring between terminal 7 on motor control relay and N.C. terminal on airflow switch.
YES
Is there voltage across terminals 7 & 4 of motor control relay?
Is there voltage to the input side of the cabinet limit?
YES
NO
Is there voltage on terminal 7 of motor control relay?
Replace fan motor.
YES
YES
Is there voltage across COM & N.C. terminal of airflow switch?
YES
Is there voltage to the input side of the stove limit?
YES
YES
Replace motor control relay.
Continued on next page.
NO
T096D
T096D
80
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
43. Will Not Heat – Steam – EDC Models (continued)
Is there voltage to the output side of the stove limit?
NO
Replace the stove limit.
NO
Correct wiring to steam valve coil.
NO
Repair or replace steam valve.
NO
Check for proper steam supply. Correct if necessary.
YES
Is there voltage across steam valve coil?
YES
Does steam valve operate properly?
YES
Is heat produced?
YES
Unit operational. T097D T097D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
81
Electronic Control Troubleshooting
44. Will Not Heat – Steam – Manual Timer Single and stacked units with and without time delay boards, manual timers.
NOTE: The following tests are conducted with the Heat Timer in the "ON" position with the machine running and calling for heat. Voltage checks are referenced to transformer neutral.
Is there voltage across terminals 1 & 6 of the temp control bd?
Is there voltage at airflow switch N.C. terminal to transformer neutral?
NO
YES
YES
NO
Adjust the airflow switch or replace if inoperative.
YES
Is there voltage at terminal 6 on CR1 to transformer neutral?
Is there voltage across terminals 5 & 6 of the temp control bd?
NO
Correct wiring between airflow switch and terminal 6 on CR1.
YES NO Is there voltage from terminal 4 on CR1 to transformer neutral? Is the thermistor shorted or open?
YES
YES
YES
YES
Is there voltage from terminal 6 on CR2 to transformer neutral? Is there voltage to terminal 3 of fan motor?
NO
Correct wiring between fan motor terminal 3 and CR1 terminal 4.
Is there voltage across terminal 3 & 5 of fan motor?
NO
Correct wiring between terminal 6 on CR2 to terminal 4 on CR1.
YES
Is there voltage from terminal 4 on CR2 to transformer neutral?
YES
CONTINUED ON NEXT PAGE
Is unit equipped with time delay board?
NO
Replace selection switch.
NO
Replace the temperature control board.
Replace CR1.
Replace thermistor.
NO
Is temperature selection switch shorted or open?
NO
NO
Replace CR2.
YES
YES Replace fan motor.
Correct wiring between CR2 terminal 4 & terminal 1 on temp control board.
NO Correct wiring between motor terminal 5 and temp control board terminal 1.
T019D
T019D
82
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
44. Will Not Heat – Steam – Manual Timer (continued) Note: Voltage checks are referenced to transformer neutral.
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and temp control board.
YES
Is heat produced?
NO
Check for proper steam supply. Correct if necessary.
YES
UNIT OPERATIONAL Is there voltage to the output side of the cabinet limit?
NO
Replace the cabinet limit.
NO
Correct wiring between stove limit and cabinet limit.
NO
Replace the stove limit.
NO
Correct wiring to the steam valve.
NO
Replace steam valve.
YES
Is there voltage to the input side of the stove limit?
YES
Is there voltage to the output side of the stove limit?
YES
Is there voltage across the coil of the steam valve?
YES
Do the steam valves operate properly?
YES T020D
T020D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
83
Electronic Control Troubleshooting
45. Will Not Heat – Steam – OPL Microprocessor Testing conducted with unit running and calling for heat. Reference voltage to transformer neutral terminal 3. Is there votlage at terminal 5 on OPL Micro?
YES
Continued on next page column 2.
Is there voltage across terminals 2 & 3 of transformer secondary?
NO
Replace transformer.
YES
NO
Note: Reference voltage to transformer secondary neutral terminal 3.
Is the thermister operating properly?
NO
Replace thermister.
Is there voltage to input of secondary fuse?
NO
Correct wiring between secondary fuse and transformer.
YES
YES Reference voltage to supply neutral.
Is power supplied to unit?
NO
Connect supply and run unit.
YES
NO
Replace secondary fuse.
YES
Is there voltage to input of primary fuse(s)?
NO
Correct wiring between primary fuse and supply.
YES
Is there voltage to N.O terminal of door switch?
NO
Correct wiring between N.O. terminal of door switch and secondary fuse.
YES
Is there voltage to output of primary fuse(s)?
NO
Change primary fuse.
YES
With door closed is there voltage to COM of door switch?
NO
Check for proper operation, replace door switch if necessary.
YES
Is there voltage across terminals 1 & 2 on primary of transformer?
YES
Is there voltage to output of secondary fuse?
NO
Correct wiring between transformer and primary fuse.
Is there voltage to N.O. of lint panel switch?
NO
Correct wiring between N.O. of lint panel switch and COM of door switch.
YES
Continued on next page column 1.
T003D
T003D
84
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
45. Will Not Heat – Steam – OPL Microprocessor (continued) Column 1
Is there voltage to COM of lint panel switch with lint panel closed?
Column 2
NO
Check for proper operation and replace lint panel switch if necessary.
Is there voltage at COM of airflow switch?
YES
Is there voltage at terminal 8 of OPL Micro?
NO
Correct wiring between terminal 8 of OPL Micro and COM of lint panel switch.
Correct wiring between COM & OPL Micro.
Is there voltage at N.C. terminal of airflow switch?
NO
Check for proper operation and replace if necessary.
YES
NO
Three phase Replace OPL Micro.
YES
Is there voltage at terminal 6 of OPL Micro?
NO
YES
YES
Is there voltage to terminal 13 of OPL Micro?
The following tests are conducted with the unit running and calling for heat.
Is the unit supplied with single phase or three phase power?
Single phase
NO
Correct wiring between terminal 6 & 13 on OPL Micro.
Is there voltage at terminal 7 of motor control relay ?
NO
Correct wiring between terminal 7 of motor control relay and N.C. of airflow switch.
YES YES Replace OPL Micro.
Is there voltage at terminal 4 of motor control relay?
Is there voltage to terminal 14 on motor control relay?
NO
YES
Correct wiring between terminal 14 on motor control relay and N.C. terminal of airflow switch.
NO
Replace motor control relay.
YES
Is there voltage at terminal 3 of fan motor centrifugal switch?
NO
Correct wiring between fan motor centrifugal switch and motor control relay.
YES
Is there votlage to terminal 13 of motor control relay?
YES
Is there voltage at terminal 5 of fan motor centrifugal switch?
NO
Replace fan motor.
NO YES Replace motor control relay.
Continued on next page. T004D
T004D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
85
Electronic Control Troubleshooting
45. Will Not Heat – Steam – OPL Microprocessor (continued) Continued from column 2 of previous page.
Is there voltage to the input of the cabinet limit?
NO
Correct wiring between cabinet limit and terminal 5 of fan motor centrifugal switch.
Is heat produced?
NO
Check for proper steam supply. Correct if necessary.
YES
YES
UNIT OPERATIONAL.
Is there voltage to output of cabinet limit?
NO
Replace cabinet limit.
YES
Is there voltage to input of stove limit?
NO
Correct wiring between stove limit and cabinet limit.
YES
Is there voltage to the output side of the stove limit?
NO
Replace stove limit.
YES
Is there voltage across steam valve coil?
NO
Correct wiring to steam valve coil.
NO
Replace or rebuild steam valve.
YES
Does the steam valve operate properly?
YES TMB1835S
TMB1835S
86
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Electronic Control Troubleshooting
46. Will Not Heat – Steam – Rotary Coin Drop Single and stacked tumblers with and without time delay.
Is there voltage across terminals 1 & 6 of the temp control board?
Is there voltage at airflow switch N.C. terminal to transformer neutral?
NO
Is there voltage at COM on switch B to transformer neutral?
Is there voltage across terminals 5 & 6 of the temp control board?
NO
Correct wiring between airflow switch and COM on switch B.
YES
NO
Is the thermistor shorted or open?
Adjust the airflow switch or replace if inoperative.
YES
YES
YES
NO
YES
Replace thermistor.
Is there voltage from N.C. on switch B to transformer neutral?
NO
Replace switch B.
NO YES Is temperature selection switch shorted or open?
YES
Replace selection switch. YES
NO Replace the temperature control board.
Is there voltage on terminal 3 of fan motor to transformer neutral?
Is the unit equipped with a time delay board?
NO
NO
Correct wiring between terminal 3 of fan motor and N.C. terminal on switch B.
Is there voltage from terminal 6 on CR2 to transformer neutral?
NO
Correct wiring between terminal 6 on CR2 to terminal N.C. on switch B.
YES
YES
With fan motor running is there voltage from terminal 5 to transformer neutral?
NO
Replace fan motor.
YES
Is there voltage on terminal 1 of temp board to transformer neutral? YES
CONTINUED ON NEXT PAGE
Is there voltage from terminal 4 on CR2 to transformer neutral?
NO
Replace CR2.
YES
NO
Correct wiring between terminal 1 of temp board to terminal 5 of fan motor.
Correct wiring between terminal 4 on CR2 & terminal 1 on temp control board.
Power supply to temp control board is good. T066D
T066D
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
87
Electronic Control Troubleshooting
46. Will Not Heat – Steam – Rotary Coin Drop (continued)
Note: Voltage checks are referenced to transformer neutral.
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and temp control board.
NO
Check for proper steam supply. Correct if necessary.
YES
YES
Is there voltage to the output side of the cabinet limit?
Is heat produced?
NO
Replace the cabinet limit.
NO
Correct wiring between stove limit and cabinet limit.
NO
Replace the stove limit.
NO
Correct wiring to steam valve
NO
Replace or rebuild steam valve.
UNIT OPERATIONAL
YES
Is there voltage to the input side of the stove limit?
YES
Is there voltage to the output side of the stove limit?
YES
Is there voltage across coil of steam valve?
YES
Does the steam valve operate properly?
YES TMB1836S
TMB1836S
88
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Section 5 Micro Display Control Troubleshooting 47. Coins Ignored When Entered Single and stacked units. Gas and electric heat. Single and three phase power supply. Start coin drop diagnostic tests.
Does the display on the electronic control increment properly?
YES
Exit diagnostic testing and reset control. (Prompting for vend price)
NO
Reconnect and run diagnostic test again.
NO
Reconnect and run diagnostic test again.
NO
Is connector H2 on the control firmly seated in its receptacle?
YES
Is the 3 pin connector between coin drop and control connected correctly?
YES
Are wires exiting coin drop optical sensor cracked or broken?
YES
Replace coin drop or optic switch.
NO
Replace coin drop. If problem still exists then replace the electronic control.
70284701
TMB1837S
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
89
Micro Display Control Troubleshooting
48. Control Has No Display (1)
Is there power supplied to the unit?
Gas, steam and electric heat. Single and three phase power supply.
NO
Plug unit in and start cycle.
Is there 24 VAC at the input of the secondary fuse?
NO
Correct wiring between secondary fuse and transformer.
YES
YES
(7)
(2)
Is there 120 VAC at input of primary fuses?
(6)
NO
Correct wiring between primary fuse and power supply.
Is there 24 VAC at output side of secondary fuse?
NO
Replace secondary fuse.
YES
YES
(8) (3)
Is there 120 VAC at output side of the primary fuses?
NO
Replace primary fuse(s).
NO
Replace Electronic Control.
YES
YES
(4)
Is there 120 VAC across terminals 1 & 2 of transformer primary?
Is there 24 VAC across H1-1 & H1-3 on the control?
NO
Correct wiring between primary fuse and transformer.
Correct wiring between control and secondary fuse.
YES
(5)
Is there 24 VAC across terminals 1 & 4 of transformer secondary?
NO
Replace transformer.
YES
TMB249S
90
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
L2
4
7
SECONDARY FUSE MDL-3.5A 250V
6
2
BLK BLK RED
RED
RED/WHT
120V
1
N.O. COM
LT. BLU
4
2
3
RED/WHT
RED/BLU
5
N.O. COM
LINT PANEL SWITCH
SECONDARY FUSE 1.25 T 250V
WHT
24V 1.5A
DOOR SWITCH
3
24V 3.5A
1
250V
AGC-2A
FUSE
PRIMARY
2
RED
RED
N
RED/BLK
RED/BLK
RED/BLK
FS-2
H2-1
H2-2
H2-5
3
MDC CONTROL
2
1
5
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT H5 6 8
7
9
10 11 12
HEAT RELAY
MOTOR RELAY
COIN DROPS 4
RED
WHT/BLU
DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED & SWITCH IS PRESSED
VOLTAGE CONFIGURATION INPUT JUMPER H2-2 TO H2-5 AS FOLLOWS: 24Vac - WIRE JUMPER 120Vac - 6.8K ohm 5 watt 240Vac - 13.6K ohm 10 watt
24Vac H1-2
2
H6 3 4
5
6
SEE VEND APPLICATION DETAIL
1
24VAC
H4
10 9
7
6
H3 5
4
7
6
5
4
3
3
2
2
100 OHM 1/4 watt 1
Door Sense Ret
TEMP. REGULATING CIRCUIT CONTROLS HEAT RELAY
8
WHT
FS-1
H2-4
H2-3
H2-6
1
WHT
H4
10 9
COM
AIR FLOW SWITCH
ORG/BRN
WHT
8
TMB1767S
CABINET LIMIT THERMOSTAT
N.O.
N.C.
BRN/RED
CHASSIS GROUND
GRN/YEL
BLK
THERMISTOR
025 & 030 MODELS
START PULSE INPUT H3-1 & H3-2 Iin= 3-30ma TIME 20msec MIN.
AVAILABLE OUTPUT H3-3 & H3-4 OPTO OFF WHEN MACHINE RUNNING Vmax=28Vdc Imax=5ma
CONTROL POWER SUPPLY
1
H1-1
CONNECTION
24Vac Ret H1-4
H1-3 24Vac Ret
L1
4N25
SERVICE
H11L1
70284701 WHT/VLT
TB1
Micro Display Control Troubleshooting
Control has no display
91
Micro Display Control Troubleshooting
49. Door Open Indicator Gas, steam and electric heat. Single and three phase power supply.
(1)
Is there voltage at H2-1 on the Electronic control?
YES Replace Control.
NO
Reference voltage checks to transformer neutral.
(6)
Is there 24 VAC at the input of the secondary fuse?
NO
Correct wiring between secondary fuse and transformer.
YES
(7)
Is there power supplied to the unit?
NO
Plug unit in and start cycle.
YES
NO
Correct wiring between primary fuses and power supply.
NO
Replace primary fuse(s).
Correct wiring between N.O. and output of secondary fuse.
With door closed is there 24 VAC to COM of door switch?
NO
Check for proper function of door switch replace if necessary.
NO
Correct wiring between N.O. on lint drawer and COM on door switch.
NO
Check for proper operation replace if necessary.
YES
(4)
(10)
NO
Correct wiring between primary fuses and transformer.
YES
Is there 24 VAC at N.O. of lint drawer switch?
YES
(5)
YES
NO
(9)
YES
Is there 24 VAC across terminals 2 & 3 of transformer secondary?
Is there 24 VAC at N.O. of door switch?
YES
(3)
Is there 120 VAC across terminals 1 & 2 of transformer primary?
Replace secondary fuse.
(8)
YES
Is there 120 VAC at output side of the primary fuses?
NO
YES
(2)
Is there 120 VAC at input of primary fuses?
Is there 24 VAC at output side of secondary fuse?
(11)
NO
Replace transformer.
Is there 24 VAC at COM of lint drawer switch with lint panel closed?
YES
Correct wiring between H2-1 of electronic control and COM of lint drawer switch.
TMB250S
92
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
7
L2
SECONDARY FUSE MDL-3.5A 250V
6
2
BLK BLK RED
RED
RED/WHT
FUSE
9
1
N.O. COM
LT. BLU
4
2
4
RED/WHT N.O. COM
LINT PANEL SWITCH
11
RED/BLU
10
SECONDARY FUSE 1.25 T 250V
WHT
24V 1.5A
DOOR SWITCH
8
3
120V
250V
AGC-2A
24V 3.5A
1
3 PRIMARY
2
RED
RED
N
RED/BLK
RED/BLK
RED/BLK
5
FS-2
H2-1
H2-2
H2-5
3
2
1
5
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT H5 6 8
7
9
10 11 12
HEAT RELAY
MOTOR RELAY
COIN DROPS 4
RED
WHT/BLU
DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED & SWITCH IS PRESSED
VOLTAGE CONFIGURATION INPUT JUMPER H2-2 TO H2-5 AS FOLLOWS: 24Vac - WIRE JUMPER 120Vac - 6.8K ohm 5 watt 240Vac - 13.6K ohm 10 watt
MDC CONTROL
24Vac H1-2
2
H6 3 4
5
6
SEE VEND APPLICATION DETAIL
1
24VAC
H4
10 9
7
6
H3 5
4
7
6
5
4
3
3
2
2
100 OHM 1/4 watt 1
Door Sense Ret
TEMP. REGULATING CIRCUIT CONTROLS HEAT RELAY
8
WHT
FS-1
H2-4
H2-3
H2-6
1
WHT
H4
10 9
COM
AIR FLOW SWITCH
ORG/BRN
WHT
8
TMB1768S
CABINET LIMIT THERMOSTAT
N.O.
N.C.
BRN/RED
CHASSIS GROUND
GRN/YEL
BLK
THERMISTOR
025 & 030 MODELS
START PULSE INPUT H3-1 & H3-2 Iin= 3-30ma TIME 20msec MIN.
AVAILABLE OUTPUT H3-3 & H3-4 OPTO OFF WHEN MACHINE RUNNING Vmax=28Vdc Imax=5ma
CONTROL POWER SUPPLY
1
H1-1
CONNECTION
24Vac Ret H1-4
H1-3 24Vac Ret
L1
4N25
SERVICE
H11L1
70284701 WHT/VLT
TB1
Micro Display Control Troubleshooting
Door open indicator
93
Micro Display Control Troubleshooting
50. Motor Will Not Start/Run Note: test conducted with vend (1) price satisfied and start button pressed. Is there voltage across H2-1 and H2-6 on the electronic control ?
NO
Single and stacked units. Gas, electric and steam heat. Single and three phase supply.
Refer to Door open flow chart.
(2)
NO
Replace control.
Does the fan motor run?
NO
Correct wiring to coil of motor relay .
3 phase. Also see Note on next page
NO Replace fan motor.
Single phase
Three phase. Also see Note on next page. (12)
Is the unit equipped with single phase or three phase power?
Is there supply voltage between L2 & L3 of motor control relay?
Single phase (4)
NO
Correct wiring between terminal 5 and power supply.
NO
Replace motor control relay.
NO
Correct wiring between L2, L3 and supply.
YES (13)
Is there voltage across terminals L2 & T2 and L3 & T3?
YES (5)
Is there voltage at terminal 8 of motor control relay?
Correct wiring between fan motor and motor control relay.
YES
Is unit equipped with single phase or three phase power supply?
YES
Is there voltage at terminal 5 of the motor control relay?
NO
YES
YES (3)
Is there voltage across the coil of the motor control relay?
(6)
Is there voltage across terminals 1 & 4 of the fan motor?
YES
Is there voltage across H2-4 and H2-6 on the electronic control?
Replace MDC Control.
YES
Replace motor control relay.
NO (7)
YES Is there voltage at terminal 6 of motor control relay?
(10)
Is there supply voltage to L1 and L2 of the motor control relay?
NO
Correct wiring between L1, L2 and power supply.
YES (11)
Is there votlage across L1 & T1 and L2 & T2?
Replace motor control relay.
Correct wiring between terminal 6 of motor control relay and supply.
YES (8)
Is there voltage at terminal 9 of motor control relay? YES
NO
NO
Replace motor control relay.
YES
NO
94
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Micro Display Control Troubleshooting
Motor will not start/run (9)
Is there voltage across terminals 1 & 4 of cylinder motor?
NO
Correct wiring between fan motor and motor control relay.
NO
Correct wiring between cylinder motor and motor control relay.
YES
Does the cylinder motor run?
NO
Replace cylinder motor.
NO Replace fan motor.
YES
Motors are operational.
Single phase Note: For high voltage three phase supply (380 volts or higher), the cylinder and fan motors are supplied by L1, L2, L3 through the motor relay terminals T1, T2, T3. Make the appropriate adjustments when doing voltage checks.
Also n next
NO
YES
NO
NO
Correct wiring between L2, L3 and supply.
Replace motor control relay.
Correct wiring between terminal 6 of motor control relay and supply.
Replace motor control relay.
TMB251S
Please see following 2 pages for wiring diagram information.
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
95
RED/BLK
RED/BLK
RED/BLK
FS-2
3
H2-1
2
1
5
4
H5 6 8
7
COIN DROPS
9
10 11 12
HEAT RELAY
MOTOR RELAY
24Vac H1-2
H2-2
DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED & SWITCH IS PRESSED
VOLTAGE CONFIGURATION INPUT JUMPER H2-2 TO H2-5 AS FOLLOWS: 24Vac - WIRE JUMPER 120Vac - 6.8K ohm 5 watt 240Vac - 13.6K ohm 10 watt
24Vac Ret
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 1
2
24VAC H6 3 4 5
6
H4
10 9
7 6
H3 5 4
7
6
WHT
5
4
3
3
2
1
2
100 OHM 1/4 watt 1
FS-1
H2-4
H2-3
H4
10 9
COM
AIR FLOW SWITCH
ORG/BRN
WHT
8
7
CABINET LIMIT THERMOSTAT
N.O.
M
3
4
BRN
5
A
3
7
2
M
1
GRN/YEL
TH
4
GND
2
WHT/ BRN
3
ICM
1
VALV
GND 3
GND 3
FAN MOTOR CENTRIFUGAL SWITCH
IGN
ORG/ WHT
VLT/WHT
4
WHT
WHT
BLK
THERMISTOR WHT
STOVE LIMIT THERMOSTAT
BRN/WHT
B
6
WHT
VLT
WHT
035 MODELS
N.C. ORG
BRN/RED
2
CHASSIS GROUND
GRN/YEL
BLK
THERMISTOR WHT
H2-6 Door Sense Ret
TEMP. REGULATING CIRCUIT CONTROLS HEAT RELAY
8
START PULSE INPUT H3-1 & H3-2 Iin= 3-30ma TIME 20msec MIN.
AVAILABLE OUTPUT H3-3 & H3-4 OPTO OFF WHEN MACHINE RUNNING Vmax=28Vdc Imax=5ma
CONTROL POWER SUPPLY
H1-1
SEE VEND APPLICATION DETAIL
H1-4
H2-5
MDC CONTROL
RED
WHT/BLU
4N25
H1-3 24Vac Ret
025 & 030 MODELS
H11L1
1
WHT/VLT
5
1
WHT
BLK
WHT/
8
5
BLK GRY/BLK
96 M
3
MAIN 1
THERM PROT.
6
MAIN 2
AUX
5
SECOND COIL
FIRST COIL
GAS VALVE
RUN
FAN MOTOR
5
4
9
6
BLK/RED BLU/BLK
4
1
RUN
MAIN 1
THERM PROT.
8
TB1-L1
9
MAIN 2
AUX
CYLINDER MOTOR
M
BLK/RED
208-240V SERVICE
TB1-L2
120V SERVICE
7
4
TMB1839S
TB1-N
Micro Display Control Troubleshooting
Motor will not start/run (Sheet 1 of 2)
70284701
LT. BLU
WHT
T3
T2
H5
H3
1
250V
AGC-2A
FUSES
PRIMARY
BLK/ WHT
2
BLK/ WHT
2
1
3
3
4
1
N.O.
COM
6
4
RED/WHT
RED/BLU
N.O.
COM
LINT PANEL SWITCH
SECONDARY FUSE 1.25 T 250V
WHT
24V 1.5A
5
DOOR SWITCH
24V 4.0A
2
SEE TRANSFORMER CONFIGURATION JUMPER
SECONDARY FUSE MDL-3.5A 250V
HC1
BLK
BLK
RED
RED
RED/WHT
RED
RED
HC2
RED/BLK
RED/BLK
RED/BLK
FS-2
H2-1
H2-2
H2-5
3
2
1
5
H5 6 8 7
9
10 11 12
HEAT RELAY
MOTOR RELAY
COIN DROPS 4
RED
WHT/BLU
1
DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED & SWITCH IS PRESSED
VOLTAGE CONFIGURATION INPUT JUMPER H2-2 TO H2-5 AS FOLLOWS: 24Vac - WIRE JUMPER 120Vac - 6.8K ohm 5 watt 240Vac - 13.6K ohm 10 watt
MDC CONTROL
24Vac H1-2
L3
24Vac Ret
1
2
24VAC H6 3 4 5
6
H4
8
7 6
H3 5 4
7
6
5
4
3
3
2
2
100 OHM 1/4 watt 1
Door Sense Ret
TEMP. REGULATING CIRCUIT CONTROLS HEAT RELAY
10 9
WHT
FS-1
H2-4
H2-3
H2-6
1
WHT
H4
10 9
COM
AIR FLOW SWITCH
ORG/BRN
WHT
8
7
CABINET LIMIT THERMOSTAT
N.O.
VLT
M
4
BRN
5
3
14
2
M
3
1
13
VLT/WHT
STOVE LIMIT THERMOSTAT
BRN/WHT
2
6
WHT
ORG/ WHT
WHT
WHT
BLK
WHT/ BRN
3
11
10
HC2
HC1
FAN MOTOR CENTRIFUGAL SWITCH
THERMISTOR WHT
035 MODELS WHT
N.C. ORG
BRN/RED
CHASSIS GROUND
GRN/YEL
BLK
THERMISTOR
025 & 030 MODELS
START PULSE INPUT H3-1 & H3-2 Iin= 3-30ma TIME 20msec MIN.
AVAILABLE OUTPUT H3-3 & H3-4 OPTO OFF WHEN MACHINE RUNNING Vmax=28Vdc Imax=5ma
CONTROL POWER SUPPLY
H1-1
SEE VEND APPLICATION DETAIL
H1-4
H1-3 24Vac Ret
L2
4N25
TB1-L3
H11L1
TB1-L2
WHT/VLT
5
T1
L1
BLK
GRY/BLK
70284701 1
M
3
BLK/WHT
4
1
13
RUN
MAIN 1
THERM PROT.
AUX MAIN 2
TMB1770S
9
MAIN 2
AUX
5
M
12
6
T3
BLK/RED
CYLINDER MOTOR
MAIN 1
THERM PROT.
M
L3
LT. BLU
FAN MOTOR
RUN
T2
L2
TB1-L3
TB1-L2
TB1-L1
BLU/BLK
TB1-L1
4
Micro Display Control Troubleshooting
Motor will not start (Sheet 2 of 2)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
97
LT. BLU
WHT
Micro Display Control Troubleshooting
51. Unit Will Not Heat (Gas) Single and stacked gas units.
Note: Tests are conducted with unit running and calling for heat.
Unit Will Not Heat (Gas)
All voltage checks are referenced to transformer neutral. (1)
Is there voltage at FS-2 of MDC control?
(7)
NO
Correct wiring between FS-2 and COM of lint drawer.
YES
Is there voltage at terminal 3 of fan motor centrifugal switch?
NO
Correct wiring between terminal 3 of fan motor centrifugal switch and terminal 4 of motor control relay.
YES Replace MDC control.
Replace thermistor. (2)
(8)
NO
Is there voltage at FS-1 of MDC control?
Is there voltage across terminals 3 & 5 of fan motor centrifugal switch?
NO
Is the thermistor operational?
YES
NO
(9)
NO
Correct wiring between COM of airflow switch and FS-1 of MDC control.
NO
Correct wiring between cabinet limit and terminal 5 of fan motor centrifugal switch.
(10)
(4)
YES
Check for proper function of airflow switch and replace if necessary.
NO
Is there voltage across cabinet limit?
YES
Replace cabinet limit.
NO
(5)
Is there voltage at terminal 7 of motor control relay?
Is there voltage to the input side of the cabinet limit?
YES
YES
Is there voltage across COM & N.C. terminal of airflow switch?
Replace fan motor.
YES
(3)
Is there voltage at COM of airflow switch?
YES
(11)
NO
Correct wiring between terminal 7 on motor control relay and N.C. terminal on airflow switch.
YES
Is there voltage to the input side of the stove limit?
NO
Correct wiring between stove limit and cabinet limit.
YES
(6)
Is there voltage across terminals 7 & 4 of motor control relay?
YES
Replace motor control relay.
NO
98
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Micro Display Control Troubleshooting
51. Unit Will Not Heat (Gas) (continued)
No Heat continued. (12)
Is there voltage across the stove limit?
YES
Replace the stove limit.
NO
YES Is there a flame?
Unit operational.
NO
(13)
Is there voltage to terminal 2 of the Ignition Control Module (ICM)?
NO
Correct wiring between terminal 2 of ICM and stove limit.
YES Note: Make sure unit is not in a lock out condition.
(14)
Is there voltage at terminal 1 of ICM board?
NO Replace ICM board.
YES
(15)
Is there voltage across the coils of the gas valve?
NO
Correct wiring between gas valve and ICM board.
NO
Replace gas valve coils or complete gas valve.
NO
Replace high voltage ignition cable or igniter.
YES
Is there gas flow through the gas valve?
YES
Does the igniter spark?
YES TMB252S
Please see following page for wiring diagram information.
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
99
RED/BLK
RED/BLK
RED/BLK
FS-2
H2-1
H2-2
3
2
1
5
4
H5 6 8
7
COIN DROPS
9
10 11 12
HEAT RELAY
MOTOR RELAY
DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED & SWITCH IS PRESSED
24Vac H1-2
H2-5
MDC CONTROL
VOLTAGE CONFIGURATION INPUT JUMPER H2-2 TO H2-5 AS FOLLOWS: 24Vac - WIRE JUMPER 120Vac - 6.8K ohm 5 watt 240Vac - 13.6K ohm 10 watt
RED
WHT/BLU
24Vac Ret
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 1
2
24VAC H6 3 4 5
6
H4
10 9
7 6
H3 5 4
7
6
WHT
5
4
3
3
2
2
2
100 OHM 1/4 watt 1
Door Sense Ret
TEMP. REGULATING CIRCUIT CONTROLS HEAT RELAY
8
START PULSE INPUT H3-1 & H3-2 Iin= 3-30ma TIME 20msec MIN.
AVAILABLE OUTPUT H3-3 & H3-4 OPTO OFF WHEN MACHINE RUNNING Vmax=28Vdc Imax=5ma
CONTROL POWER SUPPLY
H1-1
SEE VEND APPLICATION DETAIL
H1-4
H1-3 24Vac Ret
FS-1
H2-4
H2-3
H2-6
1
WHT
H4
10 9
COM
AIR FLOW SWITCH
ORG/BRN
3
WHT
8
N.O.
CABINET LIMIT THERMOSTAT
10
7
M
5
4
BRN
5
9
A
3
12
7
2
M
6
1
11
GRN/YEL
7
TH
4
GND
2
WHT/ BRN
3
8
ICM
1
VALV
3 GND 3
GND
13
FAN MOTOR CENTRIFUGAL SWITCH
IGN
ORG/ WHT
VLT/WHT
4
WHT
WHT
BLK
THERMISTOR WHT
STOVE LIMIT THERMOSTAT
BRN/WHT
B
6
WHT
VLT
WHT
035 MODELS
N.C. ORG
BRN/RED
4
CHASSIS GROUND
GRN/YEL
BLK
THERMISTOR
025 & 030 MODELS
4N25
1
H11L1
5
1
WHT
BLK
WHT/
8
BLK GRY/BLK
100 WHT/VLT
5
M
MAIN 1
THERM PROT.
MAIN 2
AUX
5
15
SECOND COIL
FIRST COIL
GAS VALVE
RUN
14
3
FAN MOTOR
4
TMB1840S
Micro Display Control Troubleshooting
Unit Will Not Heat (Gas)
70284701
LT. BLU
WHT
Micro Display Control Troubleshooting
52. Unit Will Not Heat (Steam) Single and stacked units.
Note: Tests are conducted with unit running and calling for heat. All voltage checks are referenced to transformer neutral.
(1)
Is there voltage on FS-2 of EDC control?
(7)
NO
Correct wiring between FS-2 and COM of lint drawer.
YES Replace EDC control.
Replace thermistor.
(2)
YES
Replace fan motor.
YES NO
(3)
Is there voltage on COM of airflow switch?
Correct wiring between terminal 3 of fan motor centrifugal switch and terminal 4 of motor control relay.
YES
Is there voltage across terminals 3 & 5 of fan motor centrifugal switch?
NO
Is the thermistor operational?
YES
NO
(8)
NO
Is there voltage on FS-1 of EDC control?
Is there voltage on terminal 3 of fan motor centrifugal switch?
(9)
NO
Correct wiring between COM of airflow switch and FS-1 of EDC control.
YES
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and terminal 5 of fan motor centrifugal switch.
YES (10)
(4)
Is there voltage across COM & N.C. terminal of airflow switch?
YES
Check for proper function of airflow switch and replace if necessary.
NO
Is there voltage across cabinet limit?
YES
Replace cabinet limit.
NO
(5)
Is there voltage on terminal 7 of motor control relay?
(11)
NO
Correct wiring between terminal 7 on motor control relay and N.C. terminal on airflow switch.
YES
Is there voltage to the input side of the stove limit?
NO
Correct wiring between stove limit and cabinet limit.
YES
(6)
Is there voltage across terminals 7 & 4 of motor control relay?
YES
Replace motor control relay.
NO
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
101
Micro Display Control Troubleshooting
52. Unit Will Not Heat (Steam) (continued)
No Heat continued. (12)
O
Correct wiring between terminal 3 of fan motor centrifugal switch and terminal 4 of motor control relay.
Is there voltage across the stove limit?
YES
Replace the stove limit.
NO (13)
YES
Is there voltage across the coil of the steam valve?
NO
Replace fan motor.
Correct wiring between steam valve and stove limit.
YES
O
Correct wiring between cabinet limit and terminal 5 of fan motor centrifugal switch.
Does the steam valve open allowing steam to flow?
No
Replace or rebuild steam valve.
Unit operational. ES
O
Replace cabinet limit.
Correct wiring between stove limit and cabinet limit.
TMB1841S
Please see following page for wiring diagram information.
102
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
RED/BLK
RED/BLK
RED/BLK
FS-2
H2-1
3
2
1
5
4
H5 6 8
7
COIN DROPS
9
10 11 12
HEAT RELAY
MOTOR RELAY
24Vac H1-2
H2-2
DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED & SWITCH IS PRESSED
VOLTAGE CONFIGURATION INPUT JUMPER H2-2 TO H2-5 AS FOLLOWS: 24Vac - WIRE JUMPER 120Vac - 6.8K ohm 5 watt 240Vac - 13.6K ohm 10 watt
24Vac Ret
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 1
2
24VAC H6 3 4 5
6
H4
8
7 6
H3 5 4
7
6
WHT
5
4
3
2
3
2
2
100 OHM 1/4 watt 1
Door Sense Ret
TEMP. REGULATING CIRCUIT CONTROLS HEAT RELAY
10 9
START PULSE INPUT H3-1 & H3-2 Iin= 3-30ma TIME 20msec MIN.
AVAILABLE OUTPUT H3-3 & H3-4 OPTO OFF WHEN MACHINE RUNNING Vmax=28Vdc Imax=5ma
CONTROL POWER SUPPLY
H1-1
SEE VEND APPLICATION DETAIL
H1-4
H2-5
MDC CONTROL
RED
WHT/BLU
4N25
H1-3 24Vac Ret
FS-1
H2-4
H2-3
H2-6
1
WHT
H4
10 9
COM
8
N.O.
9
CABINET LIMIT THERMOSTAT
10
7
VLT
M
5
4
BRN
5
A
12
BRN/WHT
B
6
WHT
3
7
11
M
6
1
4
7
WHT/ BRN
3
8
STEAM VALVE
13
FAN MOTOR CENTRIFUGAL SWITCH
WHT/BLK
ORG/ WHT
WHT
WHT
BLK
THERMISTOR WHT
VLT/WHT
2
STOVE LIMIT THERMOSTAT
WHT
035 MODELS
N.C. ORG
BRN/RED
4
AIR FLOW SWITCH
ORG/BRN
3
WHT
CHASSIS GROUND
GRN/YEL
BLK
THERMISTOR
025 & 030 MODELS
H11L1
70284701 WHT/VLT
1
WHT TMB1772S
5
Micro Display Control Troubleshooting
Unit Will Not Heat (Steam
103
Micro Display Control Troubleshooting
53. Unit Will Not Heat (Electric) Single and stacked units.
Note: Tests are conducted with unit running and calling for heat. All voltage checks are referenced to transformer neutral.
(1)
Is there voltage at FS-2 of EDC control?
(7)
NO
Correct wiring between FS-2 and COM of lint panel switch.
YES
Is there voltage at terminal 3 of fan motor centrifugal switch?
NO
Correct wiring between terminal 3 of fan motor centrifugal switch and terminal 13 of motor control relay.
YES Replace EDC control.
Replace thermistor. (2)
(8)
NO
Is there voltage on FS-1 of EDC control?
Is the thermistor operational?
YES
Is there voltage across terminals 3 & 5 of fan motor centrifugal switch?
NO
NO (9)
NO
Correct wiring between COM of airflow switch and FS-1 of EDC control.
YES
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and terminal 5 of fan motor centrifugal switch.
YES (10)
(4)
Is there voltage across COM & N.C. terminal of air flow switch?
Replace fan motor.
YES
(3)
Is there voltage at COM of airflow switch?
YES
YES
Check for proper function of airflow switch and replace if necessary.
NO
Is there voltage across cabinet limit?
YES
Replace cabinet limit.
NO
(5)
Is there voltage at terminal 14 of motor control relay?
(11)
NO
Correct wiring between terminal 7 on motor control relay and N.C. terminal on airflow switch.
YES
Is there voltage to the input side of the stove limit?
NO
Correct wiring between stove limit and cabinet limit.
YES
(6)
Is there voltage across terminals 13 & 14 of motor control relay?
YES
Replace motor control relay.
NO
104
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
Micro Display Control Troubleshooting
53. Unit Will Not Heat (Electric) (continued) No Heat continued.
Note: Please make the oppropriate adjustments if your unit is single phase.
(12)
ring inal 3 tor witch 13 of relay.
Is there voltage across the stove limit?
YES
Replace the stove limit.
NO (13)
Is there voltage across the coil(s) of the heater contactor(s)?
NO
Correct wiring between heater contactor and stove limit.
NO
Correct wiring between HC1 and Line voltage.
NO
Correct wiring between HC2 and Line voltage.
NO
Check for proper operation of contactors, replace them if necessary.
motor.
YES (14)
ring binet nal 5 tor witch.
Is there voltage to the L1, L2 and L3 terminals of HC1?
YES (15)
Is there voltage to the L1, L2 and L3 terminals of HC2? binet
YES (16)(17)(18)
Is there voltage across T1 & T2, T2 & T3 and T3 & T1? ring ve limit limit.
Unit is operational
YES
Do all elements produce heat?
NO
Check elements for shorts or opens. Check wires between contactors and elements.
YES
TMB1842S
Please see following page for wiring diagram information.
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
105
16
L3
CONNECTION
HC1
T1
HC2
T3
H6
H1
T1
HC2
L1
T2
HC1
L2
H4
H2
T2
HC2
L2
17
15
18
HEATING ELEMENTS
L1
L3
H5
H3 1
250V
AGC-2A
FUSES
PRIMARY
2
2
1
N.O. COM
DOOR SWITCH
6
4
RED/WHT
RED/BLU
N.O. COM
LINT PANEL SWITCH
SECONDARY FUSE 1.25 T 250V
WHT
1.5A 1
5
24V
4
4.0A 3
3
24V
2
SEE TRANSFORMER CONFIGURATION JUMPER
SECONDARY FUSE MDL-3.5A 250V
T3
HC1
L3
TB1-L3
TB1-L2
BLK/ WHT BLK/ WHT
L2
BLK BLK RED
RED
RED/WHT
RED
RED
SERVICE
RED/BLK
RED/BLK
RED/BLK
FS-2
H2-1
H2-2
H2-5
3
MDC CONTROL
2
1
5
H5 6 8 7
9
10 11 12
HEAT RELAY
MOTOR RELAY
COIN DROPS 4
RED
WHT/BLU
1
DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED & SWITCH IS PRESSED
VOLTAGE CONFIGURATION INPUT JUMPER H2-2 TO H2-5 AS FOLLOWS: 24Vac - WIRE JUMPER 120Vac - 6.8K ohm 5 watt 240Vac - 13.6K ohm 10 watt
24Vac H1-2
TB1-L1
24Vac Ret
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 1
2
24VAC H6 3 4
5
6
H4
8
7
6
H3 5
4
7
6
5
4
3
2
3
2
2
100 OHM 1/4 watt 1
Door Sense Ret
TEMP. REGULATING CIRCUIT CONTROLS HEAT RELAY
10 9
WHT
FS-1
H2-4
H2-3
H2-6
1
WHT
H4
10 9
COM
8
N.O.
9
CABINET LIMIT THERMOSTAT
10
7
VLT
4
BRN
M
5
5
3
14
2
11
M
6
1
13
7
ORG/ WHT
WHT
WHT
BLK
WHT/ BRN
3
8
HC2
HC1
13
5
WHT
TMB1773S
FAN MOTOR CENTRIFUGAL SWITCH
THERMISTOR WHT
VLT/WHT
STOVE LIMIT THERMOSTAT
12
BRN/WHT
6
WHT
035 MODELS WHT
N.C. ORG
BRN/RED
4
AIR FLOW SWITCH
ORG/BRN
3
WHT
CHASSIS GROUND
GRN/YEL
BLK
THERMISTOR
025 & 030 MODELS
START PULSE INPUT H3-1 & H3-2 Iin= 3-30ma TIME 20msec MIN.
AVAILABLE OUTPUT H3-3 & H3-4 OPTO OFF WHEN MACHINE RUNNING Vmax=28Vdc Imax=5ma
CONTROL POWER SUPPLY
H1-1
SEE VEND APPLICATION DETAIL
H1-4
H1-3 24Vac Ret
L1
4N25
14
H11L1
106 WHT/VLT
TB3
Micro Display Control Troubleshooting
Unit Will Not Heat (Electric)
70284701
Micro Display Control Troubleshooting
WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1
54. Error Codes OP - Indicates physical “open” in the thermistor circuit. Possible causes are: 1) thermistor, 2) wiring between control and thermistor, 3) control. SH - Indicates a “short” in the thermistor circuit. Possible causes are: 1) shorted thermistor, 2) a short in the wiring between control and thermistor, 3) control. Card Reader Machines: (In addition to the above errors) EC:19 - Indicates no card reader communication. The control and the reader cannot communicate. Check reader, control and harness. NOTE: For all other card reader errors, consult the card reader manual provided by the manufacturer.
Display
Corrective Action
OP
Indicates an open circuit in the thermistor. • Check thermistor. Replace if inoperative. • Check wiring between control and thermistor. Refer to wiring diagram for proper wiring. • Check control. Replace if inoperative.
SH
Indicates a short circuit in the thermistor.
• Check thermistor. Replace if inoperative. • Check wiring between control and thermistor. Refer to wiring diagram for proper wiring. • Check control. Replace if inoperative.
Indicates no communication between control and card reader.
• Check card reader. Replace if inoperative. • Check wire harness connecting card reader and control. Replace if inoperative. • Check control. Replace if inoperative.
EC:19 *Card Reader models only
70284701
Definition
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
107
L2
SECONDARY FUSE MDL-3.5A 250V
2
BLK
BLK
RED
RED
RED/WHT
1
N.O.
COM
LT. BLU
4
2
RED/WHT
RED/BLU
N.O.
COM
LINT PANEL SWITCH
SECONDARY FUSE 1.25 T 250V
WHT
24V 1.5A
DOOR SWITCH
3
120V
250V
24V 3.5A
1
AGC-2A
FUSE
RED
RED
PRIMARY
RED/BLK
RED/BLK
RED/BLK
FS-2
H2-1
H2-2
H2-5
3
MDC CONTROL
2
1
5
H5 6 8 7
9
10 11 12
HEAT RELAY
MOTOR RELAY
COIN DROPS 4
RED
WHT/BLU
DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED & SWITCH IS PRESSED
VOLTAGE CONFIGURATION INPUT JUMPER H2-2 TO H2-5 AS FOLLOWS: 24Vac - WIRE JUMPER 120Vac - 6.8K ohm 5 watt 240Vac - 13.6K ohm 10 watt
24Vac H1-2
CONNECTION
24Vac Ret
1
2
24VAC H6 3 4 5
6
H4
10 9
7 6
H3 5 4
7
6
5
4
3
3
2
2
100 OHM 1/4 watt 1
Door Sense Ret
TEMP. REGULATING CIRCUIT CONTROLS HEAT RELAY
8
WHT
FS-1
H2-4
H2-3
H2-6
1
WHT
H4
10 9
COM
AIR FLOW SWITCH
ORG/BRN
WHT
8
7
CABINET LIMIT THERMOSTAT
N.O.
M
4
BRN
5
VLT
A
3
7
2
M
1
GRN/YEL
TH
4
GND
2
WHT/ BRN 3
ICM
1
VALV
3 GND 3
GND
FAN MOTOR CENTRIFUGAL SWITCH
IGN
ORG/ WHT
VLT/WHT
4
WHT
WHT
BLK
THERMISTOR WHT
STOVE LIMIT THERMOSTAT
BRN/WHT
B
6
WHT
035 MODELS WHT
N.C. ORG
BRN/RED
CHASSIS GROUND
GRN/YEL
BLK
THERMISTOR
025 & 030 MODELS
START PULSE INPUT H3-1 & H3-2 Iin= 3-30ma TIME 20msec MIN.
AVAILABLE OUTPUT H3-3 & H3-4 OPTO OFF WHEN MACHINE RUNNING Vmax=28Vdc Imax=5ma
CONTROL POWER SUPPLY
H1-1
SEE VEND APPLICATION DETAIL
H1-4
H1-3 24Vac Ret
5
1
WHT
BLK
WHT/
8
5
BLK GRY/BLK
M
3
MAIN 1
THERM PROT.
MAIN 2
AUX
5
SECOND COIL
FIRST COIL
GAS VALVE
RUN
FAN MOTOR
4
9
6
1
120V SERVICE
BLK/RED
RUN
MAIN 1
THERM PROT.
MAIN 2
AUX
CYLINDER MOTOR
M
208-240V SERVICE
TB1-L2
TB1-L1
4
TB1-N
9
7
COIN DROP 2 (OPTIONAL)
10 11 12
1
2
3
4 H6
5
6
5
4
6
7
9
10 11 12
1
2
3
4 H6
5
7
7
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
4. CONNECT ELECTRICAL SERVICE OF PROPER VOLTAGE AND CURRENT RATING TO TB1.
3. THERMOSTAT: OPENS WHEN TEMPERATURE IS REACHED.
2. MOTORS ARE PROTECTED BY INTERNAL OVERLOADS.
6
6
5
5
4
4
3
3
1
1
H3
H3
TMB1775S
2
2
TMB1775S
PLEASE CONSULT CARD READER INSTALLATION MANUAL FOR PROPER CONNECTIONS TO CONTROL
6
CARD READER READY VEND OPTION
JUMPER
8
COIN DROP VEND OPTION SINGLE, DUAL AND COIN DROP READY
COIN VAULT SWITCH
SERVICE DOOR SWITCH
1
2
3
8
COIN DROP 1 (OPTIONAL)
6
4
5
SERVICE DOOR SWITCH
1
2
3
VEND APPLICATION DETAILS
1. DOOR SWITCH: N.O. CONTACT CLOSED WHEN DOOR CLOSED.
NOTES:
H5
H5 RED
N
4N25
GRY GRY
BLU
L1
H11L1
BRN BRN
BLK/RED BLU/BLK
BLK
WHT
TB1
WHT/VLT
PNK PNK
BLK
WHT
108
SERVICE
Micro Display Control Troubleshooting
Gas Models Schematic
70284701
LT. BLU
WHT
LT. BLU
BRN/ WHT
WHT/ BRN
1
3
5
B
9
WHT
WHT/BLK
8 8
2 2
1 1 6 6
9 9 5 5
WHT 3 3
WHT
RED
2 2
BRN/RED
WHT/BLU
RED/BLU
1
4
3
1
5
4
4
4
2
LOW
BLU
BRN
FAN MOTOR
BRN BLU
2 4 LOW
CYLINDER MOTOR
GAS VALVE
WHT/VLT
VLT
CABINET LIMIT THERMOSTAT
WHT WHT/ BLK
GRN/YEL
GRN/YEL
GRN/YEL
WHT
WHT/BLK
COM.
ORG/BRN
N.O.
N.C.
AIR FLOW SWITCH
VLT/WHT
ORG
STOVE LIMIT THERMOSTAT
WHT
THERMISTOR
7 7
4 4
BLK
BRN/WHT
1 1
7 7
8 8
9 9
5 5 10 10
5
4
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT BLU
WHT RED
3 3 1 1
GRY
GRY
BRN
SERVICE DOOR SWITCH
COIN DROP 2 (OPTIONAL)
BLK
2 2
COIN DROP 1 (OPTIONAL)
COIN VEND OPTION SINGLE, DUAL AND COIN DROP READY
7
6
5
4
3
2
1
6
5
4
3
2
1
1
3
H3
BLK WHT
2
8
RED
1 1
RED
7
WHT
3 3
WHT
9
10
BLK
2 2
BLK
5
4
3
H4
10 5 10 5
10
9
8
7
6
9 9
12
H3
H6
BLK
PNK
GRY
BRN
BLU
WHT
BLK
RED
WHT
1
3
2
1
3
2
2 2
8 8
7 7 1 1
2 2
3 3
5
H2 3
GRY
GRY
1
SECONDARY FUSE
SERVICE DOOR SWITCH
PLEASE CONSULT CARD READER INSTALLATION MANUAL FOR PROPER CONNECTION TO CONTROL
3 3
MDC CONTROL
2
6 11 12 13 14 6 11 12 13 14
BRN
4 4
6
H4
WHT/BLU
RED/WHT
RED/BLU
ORG
WHT/VLT
BRN/RED
4
10
9
8
7
6
5
4
3
1 2
BLK WHT
025 & 030 MODELS
1 1
CARD READER READY VEND OPTION
7
6
5
4
3
2
1
6
5
4
3
2
1
1
3
2
8
7
9
10
5
4
H5
VEND APPLICATION DETAILS
GRN/YEL
WHT/VLT
RED/WHT
WHT
PNK/BLK
WHT/BLU
PNK
RED
RED/BLU
BRN
ORG/WHT
BRN/RED
WHT/BRN
BRN/WHT
6
2 2
11
PNK
3 3
6
H6
H5
4 4
11
2 2
035 MODELS
11
12
14 13 12 11 6 14 13 12 11 6
WHT/BRN
BLK BLK
TRANSFORMER
RED
1 1
RED
RED
4 4
BRN
8
RED
3 3
2
A
7
6
WHT
ORG/WHT
22 1 1
4
BLK
MOTOR RELAY
4
5
6
3
2
WHT
5
IGNITION CONTROL MODULE
GRY/ BLK
LT. BLU
BLU/ BLK
LT. BLU
IGNITOR
11
BLU/BLK
SERVICE GROUND
WHT/BRN
LT. BLU
2 2
BRN/WHT
VLT/WHT
CONNECT BLK/RED TO L1 FOR 120V SERVICE AND TO L2 FOR FOR 208V AND 240V SERVICE.
GRY/BLK
TB1
BLK/RED
GRY/BLK
L2
BLK/RED
ORG/WHT
LT. BLU LT. BLU
BRN
N
BLK/RED BLU/ BLK
SERVICE CONNECTION PRIMARY FUSE SECONDARY FUSE
1
WHT/BRN
2
WHT
BLK
RED/BLK
WHT
RED/BLK
2
WHT
1
ORG/BRN
1
RED/BLK
BLK
WHT/ORG
1
2
H1 3
4 10 7 4 10 7
RED
BLK BLK RED RED
FS-2 FS-1 GND GRN/YEL
BLK
RED/BLU
WHT/BLU
1 2 3 4 5 6 7
1 2 3 4 5 6
12 11 6 4 5 10 9 7 8 2 3 1
14 15 13 5 14 15 13 5
4
H3
H6
H5
BLK
BLK/RED
WHT
BLK
WHT/VLT
6 6
9 9
2
1
RED/ BLK
RED/WHT
LINT PANEL SWITCH
N.O.
GRY
PNK
COM.
2 2
BLK 8 12 11 1 8 12 11 1
WHT
SEE VEND APPLICATION DETAIL
GRY
70284701 PNK
L1
1 1
3 3
RED/ WHT
6 6
4 4
5 5
2 2
COM.
GRY
N.O.
N.O.
DOOR SWITCH
COM.
COIN MODELS
COIN VAULT SWITCH
PNK
2
1
3
6
4
5 CARD READER MODELS
BYPASS JUMPER
TMB1778S
BLK
BLK
Micro Display Control Troubleshooting
Gas Models Connection Diagram
109
L2
SECONDARY FUSE MDL-3.5A 250V
2
BLK
BLK
RED
RED
RED/WHT
N.O.
COM
DOOR SWITCH
1
LT. BLU
4
2
RED/WHT
RED/BLU
N.O.
COM
LINT PANEL SWITCH
SECONDARY FUSE 1.25 T 250V
WHT
1.5A
3.5A
3
24V
120V
24V
1
FUSE
250V
AGC-2A
RED
RED
RED/BLK
RED/BLK
RED/BLK
FS-2
H2-1
H2-2
H2-5
3
2
1
5
H5 6 8 7
9
10 11 12
HEAT RELAY
MOTOR RELAY
COIN DROPS 4
RED
DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED & SWITCH IS PRESSED
VOLTAGE CONFIGURATION INPUT JUMPER H2-2 TO H2-5 AS FOLLOWS: 24Vac - WIRE JUMPER 120Vac - 6.8K ohm 5 watt 240Vac - 13.6K ohm 10 watt
MDC CONTROL
WHT/BLU
2
H1-1 H6 3 4 5
6
SEE VEND APPLICATION DETAIL
1
24VAC
H1-3
8
7 6
H3 5 4
7
6
5
4
3
3
2
2
100 OHM 1/4 watt 1
Door Sense Ret
TEMP. REGULATING CIRCUIT CONTROLS HEAT RELAY
10 9
START PULSE INPUT H3-1 & H3-2 Iin= 3-30ma TIME 20msec MIN.
AVAILABLE OUTPUT H3-3 & H3-4 OPTO OFF WHEN MACHINE RUNNING Vmax=28Vdc Imax=5ma
CONTROL POWER SUPPLY
H4
WHT
FS-1
H2-4
H2-3
H2-6
1
WHT
H4
10 9
COM
AIR FLOW SWITCH
ORG/BRN
WHT
8
7
CABINET LIMIT THERMOSTAT
N.O.
VLT
M
4
BRN
5
A
3
7
M
1
4
VLT/WHT
2
STOVE LIMIT THERMOSTAT
BRN/WHT
B
6
WHT
WHT/ BRN 3
STEAM VALVE
FAN MOTOR CENTRIFUGAL SWITCH
WHT/BLK
ORG/ WHT
WHT
WHT
BLK
THERMISTOR WHT
035 MODELS WHT
N.C. ORG
BRN/RED
CHASSIS GROUND
GRN/YEL
BLK
THERMISTOR
025 & 030 MODELS
5
8
5
BLK GRY/BLK
PRIMARY
24Vac H1-2
1
M
3 RUN
MAIN 1
THERM PROT.
5
MAIN 2
AUX
FAN MOTOR
4
9
6
BLK/RED BLU/BLK
CONNECTION
24Vac Ret H1-4
1
120V SERVICE
BLK/RED
RUN
MAIN 1
THERM PROT.
MAIN 2
AUX
CYLINDER MOTOR
M
208-240V SERVICE
TB1-L2
TB1-L1
4
TB1-N
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
9
7
COIN DROP 2 (OPTIONAL)
10 11 12
1
2
3
4 H6
5
6
5
4
6
7
9
10 11 12
1
2
3
4 H6
5
7
7
6
6
5
5
4
4
3. HEATER RELAY OPENS WHEN TEMPERATURE IS REACHED.
2. MOTOR IS PROTECTED BY INTERNAL THERMAL PROTECTOR.
3
3
2
2
1
1
H3
H3
TMB1776S TMB1776S
PLEASE CONSULT CARD READER INSTALLATION MANUAL FOR PROPER CONNECTIONS TO CONTROL
6
CARD READER READY VEND OPTION
JUMPER
8
COIN DROP VEND OPTION SINGLE, DUAL AND COIN DROP READY
COIN VAULT SWITCH
SERVICE DOOR SWITCH
1
2
3
8
COIN DROP 1 (OPTIONAL)
6
4
5
SERVICE DOOR SWITCH
1
2
3
VEND APPLICATION DETAILS
1. DOOR SWITCH - CONTACTS CLOSED WHEN DOOR CLOSED.
NOTES:
H5
H5
GRY GRY
24Vac Ret
BRN BRN
BLU
N
4N25
RED
L1
H11L1
BLK
WHT
TB1
WHT/VLT
PNK PNK
BLK
WHT
110
SERVICE
Micro Display Control Troubleshooting
Steam Models Schematic
70284701
LT. BLU
LT. BLU
WHT
SERVICE CONNECTION
LT. BLU
BRN/ WHT
WHT/ BRN
GRY/ BLK
LT. BLU
BLU/ BLK
3
1
1
5
4
4
STEAM VALVE
BLU/BLK
GRN/YEL
4 LOW
BLU
BRN
FAN MOTOR
BRN BLU
2
2
4
A
7
5
WHT/VLT
VLT
8
9
6
WHT
WHT
1
WHT/BLK
4
5
6
3
2
ORG/BRN
N.O.
N.C.
AIR FLOW SWITCH
VLT/WHT
ORG
STOVE LIMIT THERMOSTAT
COM.
B
MOTOR RELAY
BLK
CABINET LIMIT THERMOSTAT
4 LOW
ORG/WHT 22 1 1
GRY/BLK GRN/YEL
CYLINDER MOTOR
SERVICE GROUND
11
WHT/BRN
LT. BLU
2 2
BRN/WHT
WHT WHT/ BLK
CONNECT BLK/RED TO L1 FOR 120V SERVICE AND TO L2 FOR FOR 208V AND 240V SERVICE.
GRY/BLK
TB1
BLK/RED
BLK/RED
BRN
L2 BLK/RED BLU/ BLK
LT. BLU LT. BLU
8 8
1 1 6 6
9 9 5 5
7 7
THERMISTOR
2 2
VLT/WHT
WHT
4 4
3 3
BLK
WHT
WHT/BLU BRN/RED
10 10
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT BLU
8
RED
3 3 1 1
GRY
GRY
BRN
SERVICE DOOR SWITCH
COIN DROP 2 (OPTIONAL)
BLK WHT
2 2
COIN VEND OPTION SINGLE, DUAL AND COIN DROP READY
7
6
5
4
3
2
1
6
5
4
3
2
1
1
3
H3
BLK WHT
7 2
9
COIN DROP 1 (OPTIONAL)
RED
9 9
H3
H6
H5
BLK
PNK
GRY
BRN
BLU
WHT
BLK
RED
WHT
2
1
3
2
1
3
2 2
8 8
7 7 1 1
2 2
GRY
GRY
1
SERVICE DOOR SWITCH
PLEASE CONSULT CARD READER INSTALLATION MANUAL FOR PROPER CONNECTION TO CONTROL
3 3
MDC CONTROL
2
6 11 12 13 14 6 11 12 13 14
BRN
4 4
5
H2 3
WHT/BLU
RED/WHT
3 3
6
H4
SECONDARY FUSE
4
10
9
8
7
6
5
4
3
1 2
BLK WHT
RED/BLU
ORG
WHT/VLT
BRN/RED
025 & 030 MODELS
1 1
CARD READER READY VEND OPTION
7
6
5
4
3
2
1
6
5
4
3
2
1
1
3
2
8
7
9
10
5
4
1 1
12
RED
5 10
H4
10 5 10 5
10
9
8
7
6
5
4
3
VEND APPLICATION DETAILS
GRN/YEL
WHT/VLT
RED/WHT
WHT
PNK/BLK
WHT/BLU
PNK
RED
RED/BLU
BRN
ORG/WHT
BRN/RED
WHT/BRN
BRN/WHT
6
BLK
5 5
11
9 9
WHT
8 8
3 3
2 2
7 7
BLK
1 1
WHT
2 2
4
PNK
3 3
6
H6
H5
4 4
11
2 2
035 MODELS
11
12
14 13 12 11 6 14 13 12 11 6
WHT/BRN
BRN/WHT
BRN
ORG/WHT
BLK BLK
TRANSFORMER
RED
2 2
RED/BLU
RED RED
1 1
RED
4 4
3 3
PRIMARY FUSE SECONDARY FUSE
N
WHT/BRN
1
WHT
2
RED/BLK
BLK
RED/BLK
WHT
WHT
2
ORG/BRN
1
RED/BLK
BLK
WHT/ORG
1
2
H1 3
4 10 7 4 10 7
RED
BLK BLK RED RED
FS-2 FS-1 GND GRN/YEL
BLK
RED/BLU
WHT/BLU
1 2 3 4 5 6 7
1 2 3 4 5 6
12 11 6 4 5 10 9 7 8 2 3 1
14 15 13 5 14 15 13 5
4
H3
H6
H5
BLK
BLK
WHT
BLK/RED
WHT/VLT
6 6
9 9
2
1
RED/ BLK
RED/WHT
LINT PANEL SWITCH
N.O.
GRY
PNK
COM.
2 2
BLK 8 12 11 1 8 12 11 1
WHT
SEE VEND APPLICATION DETAIL
GRY
70284701 PNK
L1
RED/ WHT
6 6
4 4
5 5
2 2
1 1
3 3
COM.
GRY
N.O.
N.O.
DOOR SWITCH
COM.
COIN MODELS
COIN VAULT SWITCH
PNK
2
1
3
6
4
5 CARD READER MODELS
BYPASS JUMPER
TMB1777S
BLK
BLK
Micro Display Control Troubleshooting
Steam Models Connection Diagram
111
WHT
LT. BLU
L3
HC2
HC1
T1
HC2
T3
HEATING ELEMENTS
1
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
2
3
4
3
3
4
1
5
N.O.
2
JUMPER
RED/WHT
RED/BLU
N.O. COM
LINT PANEL SWITCH
SECONDARY FUSE 1.25 T 250V
4
6
2 1
4
240V
3 5
6
FS-2
H2-1
H2-2
H2-5
CONFIGURATION JUMPER
2
RED/BLK
RED/BLK
RED/BLK
230-240V MODELS
1
TRANSFORMER CONFIGURATION JUMPER DETAILS
COM
6
WHT
24V 1.5A
5
DOOR SWITCH
24V 4.0A
2
208V CONFIGURATION
2
1
200-208V MODELS
1
1
250V
AGC-2A
FUSES
PRIMARY
SEE TRANSFORMER CONFIGURATION JUMPER
SECONDARY FUSE MDL-3.5A 250V
H5
H4
H6
T3
HC1
H3
T2
HC2
TB1-L3
L3
H2
T2
HC1
L2 BLK/ WHT BLK/ WHT
L2
H1
T1
L1
L1
BLK
BLK
RED
RED
RED/WHT
RED
RED
L3
3
2
2
1
5 4
H5 6 8 7
COIN DROPS 9
10 11 12
HEAT RELAY
MOTOR RELAY
DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED & SWITCH IS PRESSED
VOLTAGE CONFIGURATION INPUT JUMPER H2-2 TO H2-5 AS FOLLOWS: 24Vac - WIRE JUMPER 120Vac - 6.8K ohm 5 watt 240Vac - 13.6K ohm 10 watt
MDC CONTROL
RED
WHT/BLU
24Vac Ret
2
H1-1 H6 3 4 5
6
SEE VEND APPLICATION DETAIL
1
24VAC
H4
8
7 6
H3 5 4
7
6
5
4
3
3
2
2
100 OHM 1/4 watt 1
Door Sense Ret
TEMP. REGULATING CIRCUIT CONTROLS HEAT RELAY
10 9
WHT
FS-1
H2-4
H2-3
H2-6
1
WHT
H4
10 9
COM
AIR FLOW SWITCH
ORG/BRN
WHT
8
7
CABINET LIMIT THERMOSTAT
N.O.
VLT
M
4
BRN
5
3
14
2
M
1
13
ORG/ WHT
WHT
WHT
BLK
WHT/ BRN 3
HC2
HC1
FAN MOTOR CENTRIFUGAL SWITCH
THERMISTOR WHT
VLT/WHT
STOVE LIMIT THERMOSTAT
BRN/WHT
6
WHT
035 MODELS WHT
N.C. ORG
BRN/RED
CHASSIS GROUND
GRN/YEL
BLK
THERMISTOR
025 & 030 MODELS
START PULSE INPUT H3-1 & H3-2 Iin= 3-30ma TIME 20msec MIN.
AVAILABLE OUTPUT H3-3 & H3-4 OPTO OFF WHEN MACHINE RUNNING Vmax=28Vdc Imax=5ma
CONTROL POWER SUPPLY
H1-3 24Vac Ret
CONNECTION
4N25
5
T1
L1
BLK
GRY/BLK
L2
1
M
3
BLK/WHT
MAIN 1
THERM PROT.
M
T3
AUX
5
M
MAIN 2
L3
BLK/RED
FAN MOTOR
RUN
T2
L2
4
TB1-L1
TB1-L3
TB1-L2
BLU/BLK
TB1-L1
24Vac H1-2
1
MAIN 1
THERM PROT.
AUX MAIN 2
4
LT. BLU
H5
H5
3
2
1
5
4
6
COIN DROP 2 (OPTIONAL)
10 11 12
1
2
3
4 H6
5
6
8
7
9
10 11 12
1
2
3
4 H6
5
7
7
6
6
5
5
4
4
3
3
3. HEATER RELAY OPENS WHEN TEMPERATURE IS REACHED.
2. MOTOR IS PROTECTED BY INTERNAL THERMAL PROTECTOR.
2
2
1
1
H3
H3
TMB1774S TMB1774S
PLEASE CONSULT CARD READER INSTALLATION MANUAL FOR PROPER CONNECTIONS TO CONTROL
6
CARD READER READY VEND OPTION
JUMPER
SERVICE DOOR SWITCH
1
2
9
7
COIN DROP VEND OPTION SINGLE, DUAL AND COIN DROP READY
COIN VAULT SWITCH
SERVICE DOOR SWITCH
3
8
COIN DROP 1 (OPTIONAL)
6
4
5
VEND APPLICATION DETAILS
1. DOOR SWITCH - CONTACTS CLOSED WHEN DOOR CLOSED.
NOTES:
CYLINDER MOTOR
RUN
BLU
TB1-L2
H11L1
RED
L1
WHT/VLT
BLK
WHT
SERVICE
GRY GRY
BRN BRN
H1-4
PNK PNK
BLK
112 WHT
TB3
Micro Display Control Troubleshooting
Electric Models Schematic
70284701
LT. BLU
WHT
H3
H2
H1
ELECTRIC HEATER
H5
BRN/ WHT
WHT/ BRN
GRY/ BLK
LT. BLU
H6
H4
LT. BLU
1
NOTE: SEE MOTOR CHART BELOW FOR INTERNAL JUMPER CONNECTIONS
FAN MOTOR
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
5
2 1
SERVICE
SERVICE GROUND GND
14
13 L2 L3
T3
WHT/BLK
T2
L3
L2
L1
T3
T2
T1
T3
T2
T1
BLK
BLK/WHT
ORG/BRN
N.O.
N.C.
AIR FLOW SWITCH
VLT/WHT
ORG
STOVE LIMIT THERMOSTAT
WHT
T1
BLK/RED
WHT
L1
MOTOR CONTACTOR
COM.
WHT
ORG/WHT VLT/WHT
WHT/VLT
VLT
CABINET LIMIT THERMOSTAT
GRN/YEL
GRN/YEL
VLT/WHT
CONNECTION
NOTE: SEE MOTOR JUMPER CHART BELOW FOR INTERNAL JUMPER CONNECTIONS
3 JUMPER
1
4
4
1 1
CYLINDER MOTOR
3 3
WHT
VLT/WHT
LT. BLU
2 2
1 1
WHT/BRN
BLU/BLK
2 2
BRN/WHT
GRY/BLK
LT. BLU
TB1
BLK/RED
BRN
BLK/RED
BLU/ BLK
TB3
HC1
HC2
2 2
1 1
6 6
9 9 5 5
7 7
THERMISTOR
L3
L2
L1
L3
L2
L1
8 8
WHT
4
5
6
3
2
1
SEE
5 4 3
2
1
4 4
3 3
3 3
BLK
WHT
4 4
1 1 RED
BRN/RED
WHT/BLU
RED/BLU
14 13 12 11 6 14 13 12 11 6
WHT/BRN
BRN/WHT
BRN
ORG/WHT
2 2
TRANSFORMER
6
DETAILS
JUMPER
TRANSFORMER
4 4
3 3 2 2
BLK/WHT 1 1
BLK/WHT
2
WHT
L3
BLK/WHT
PRIMARY FUSE 7 7
8 8
10 10
HIGH HIGH N.A.
240V/60HZ 230-240V/50HZ
CONF.
6 2
6 2
NONE
BLU
BLU BRN
BRN
JUMPER CONNECTION
MOTOR JUMPER CHART
GRN/YEL
WHT/VLT
RED/WHT
WHT
PNK/BLK
WHT/BLU
PNK
RED
RED/BLU
BRN
ORG/WHT
BRN/RED
WHT/BRN
BRN/WHT
SERVICE VOLTAGE
5 5
200-208V/60HZ 200V/50HZ
9 9
035 MODELS
H4
10 5 10 5
10
9
8
7
6
5
4
3
2
WHT
WHT/BRN
BLK/WHT BLK/WHT
PRIMARY FUSE SECONDARY FUSE
WHT/BLU 14 15 13 5 14 15 13 5
6 6
9 9
RED/BLU
8 12 11 1 8 12 11 1
BLK
WHT
5
BLU
7
6
5
4
3
2
1
6
5
4
3
2
1
1
3
H3
BLK WHT 8 2
7
RED 9
10
WHT RED
3 3 1 1
GRY
GRY
BRN
SERVICE DOOR SWITCH
COIN DROP 2 (OPTIONAL)
BLK
COIN DROP 1 (OPTIONAL)
RED
WHT
2 2
1 1
3 3
N.O.
GRY
PNK
RED/WHT
LINT PANEL SWITCH
COM.
2 2
12
H3
H6
H5
BLK
PNK
GRY
BRN
BLU
WHT
BLK
RED
WHT
1
3
2
1
3
2
RED/ WHT
6 6
4 4
5 5
2 2
1 1
3 3
COM.
GRY
N.O.
N.O.
GRY
GRY
BRN
2
1
3
BLK
BLK
CARD READER MODELS
BYPASS JUMPER
PLEASE CONSULT CARD READER INSTALLATION MANUAL FOR PROPER CONNECTION TO CONTROL
6
4
5
SERVICE DOOR SWITCH
DOOR SWITCH
COM.
COIN MODELS
COIN VAULT SWITCH
PNK
CARD READER READY VEND OPTION
7
6
5
4
3
2
1
6
5
4
3
2
1
1
3
2
8
7
9
10
5
4
6
BLK
4 10 7 4 10 7
1 2
WHT/BLU
VEND APPLICATION DETAILS
3 3
4
11 2 2
6 11 12 13 14 6 11 12 13 14
PNK
4 4
2
H1 3
BLK
3 3
1
1 2 3 4 5 6 7
SEE VEND APPLICATION DETAIL
WHT
2 2
1
SECONDARY FUSE
2
H3
H6
1 2 3 4 5 6
6
1 1
5
H2 3
MDC CONTROL
H5
4
H6
H5
7 7
6
H4
RED/WHT
RED/BLU
4
10
9
8
7
6
5
4
12 11 6 4 5 10 9 7 8 2 3 1
11
12
8 8
ORG
WHT/VLT
BRN/RED
2
WHT 3
1
BLK
COIN VEND OPTION SINGLE, DUAL AND COIN DROP READY
9 9
2 2
025 & 030 MODELS
1 1
WHT
1
RED/BLK
BLK
RED/BLK
L2
BRN/RED WHT/ORG
BLU/ BLK
BLK/ RED
WHT
WHT
2
ORG/BRN
1
RED/BLK
1
VLT/WHT
RED
BLK BLK RED RED
FS-2 FS-1 GND GRN/YEL
BLK
BLK
BLK
WHT
L1
RED/BLK
BLK/ WHT
WHT/VLT
GRY
70284701 PNK
BLK
2
5
1 2
6
5 6
1
4
4
1
2
1
230-240V MODELS 240V JUMPER
2
TMB1779S
3
3
200V & 208V MODELS 208V JUMPER
TRANSFORMER JUMPER DETAILS
Micro Display Control Troubleshooting
Electric Models Connection Diagram
113
Section 6 NetMaster Troubleshooting WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. • Never start the tumbler with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded. W002
55. No IR Communication IR Communication Single and stacked. Gas and electric heat. Single and three phase power supply.
Attempt to communicate with the electronic control from the microwand.
No IR Communication
Check the following:
Is there a response of any kind from the electronic control?
NO
Aim microwand closer and try again.
YES
Does the electronic control display E:OF or -C-?
Does the control respond?
NO
- low battery on microwand - is the IR window covered or blocked on the control. - if needed replace the electronic control - is the IR cap properly attached to the microwand.
YES
-C-
Communication sequence checks out.
"E:OF"
Check the following: - IR communication disabled by manual programming. - Is the IR window on the control covered or blocked. - if needed, change control board.
TMB247S
TMB247S
114
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
56. Coins Ignored When Entered
Single and stacked units. Gas and electric heat. Single and three phase power supply. Start coin drop diagnostic tests.
Does the display on the electronic control increment properly?
YES
Exit diagnostic testing and reset control. (Prompting for vend price)
NO
Reconnect and run diagnostic test again.
NO
Reconnect and run diagnostic test again.
NO
Is connector H5 on the control firmly seated in its receptacle?
YES
Is the 3 pin connector between coin drop and control connected correctly?
YES
Are wires exiting coin drop optical sensor cracked or broken?
YES
Replace coin drop or optic switch.
NO
Replace coin drop. If problem still exists then replace the electronic control.
70284701
TMB1843S
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
115
NetMaster Troubleshooting
57. Control Has No Display Gas, steam and electric heat. Single and three phase power supply.
(1)
Is there power supplied to the unit?
NO
Plug unit in and start cycle.
(6)
Is there 24 VAC at the input of the secondary fuse?
NO
Correct wiring between secondary fuse and transformer.
YES
YES
(7)
(2)
Is there 120 VAC at input of primary fuses?
NO
Correct wiring between primary fuse and power supply.
Is there 24 VAC at output side of secondary fuse?
NO
Replace secondary fuse.
YES
YES
(8) (3)
NO
Is there 120 VAC at output side of the primary fuses?
Replace primary fuse(s).
Is there 24 VAC across H1-1 & H1-3 on the control?
NO
Replace Electronic Control.
YES
YES
(4)
Is there 120 VAC across terminals 1 & 2 of transformer primary?
NO
Correct wiring between primary fuse and transformer.
Correct wiring between control and secondary fuse.
YES
(5)
Is there 24 VAC across terminals 1 & 4 of transformer secondary?
NO
Replace transformer.
YES
TMB249S TMB249S
Please see following 2 pages for wiring diagram information. 116
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
Control Has No Display (Sheet 1 of 2)
2 3
5
1
4
6 7
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
117
NetMaster Troubleshooting
Control Has No Display (Sheet 2 of 2)
TMB269S
TMB269S
118
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
58. Door Open Indicator (1)
Is there voltage at H2-1 on the Electronic control?
Single and stacked units. Gas, steam and electric heat. Single and three phase supply.
Reference voltage checks to transformer neutral.
YES Replace Control.
NO
(6)
Is there voltage at the input of the secondary fuse?
NO
Correct wiring between secondary fuse and transformer.
YES
(7)
Is there power supplied to the unit?
NO
Plug unit in and run it.
YES
NO
Replace secondary fuse.
YES
(2)
Is there voltage at input of primary fuses?
(8)
NO
Correct wiring between primary fuses and power supply.
YES
Is there voltage at N.O. of door switch?
NO
Correct wiring between N.O. and output of secondary fuse.
NO
Check for proper function of door switch replace if necessary.
NO
Correct wiring between N.O. on lint panel and COM on door switch.
NO
Check for proper operation replace if necessary.
YES
(3)
Is there voltage at output side of the primary fuses?
(9)
NO
Replace primary fuse(s).
YES
With door closed is there voltage to COM of door switch?
YES
(4)
Is there voltage across terminals 1 & 2 of transformer primary?
(10)
NO
Correct wiring between primary fuses and transformer.
YES
Is there voltage at N.O. of lint panel switch?
YES
(5)
Is there voltage across terminals 2 & 3 of transformer secondary?
YES
Is there voltage at output side of secondary fuse?
(11)
NO
Replace transformer.
Is there voltage at COM of lint panel switch with lint panel closed?
YES
Correct wiring between H2-1 of electronic control and COM of lint panel switch.
TMB1844S
Please see following 2 pages for wiring diagram information. 70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
119
NetMaster Troubleshooting
Door Open Indicator (Sheet 1 of 2)
2 3
4
1
5
6
7 8
120
9
10
11
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
Door Open Indicator (Sheet 2 of 2)
TMB270S
TMB270S
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
121
NetMaster Troubleshooting
59. Motor Will Not Start/Run Motor Start/Run Note: test conducted with vend (1) price satisfied and start button pressed. Is there voltage across H2-1 and H2-6 on the electronic control ?
NO
Single and stacked units. Gas, electric and steam heat. Single and three phase supply.
Refer to "Door open" flow chart.
Motor (cylinder/fan)will not start/run
Replace electronic Control.
(6)
Is there voltage across terminals 1 & 4 of the fan motor?
YES (2) Is there voltage across H2-4 and H2-6 on the electronic control?
NO
Replace control.
Does the fan motor run?
NO
Correct wiring between fan motor and motor control relay.
YES
YES (3)
Is there voltage across the coil of the motor control relay?
NO
Correct wiring to coil of motor relay .
3 phase. Also see note on next page
Replace fan motor.
YES
Is unit equipped with single phase or three phase power supply?
YES
NO
Single phase
Three phase. Also see note on next page. (12)
Is the unit equipped with single phase or three phase power?
Is there supply voltage between L2 & L3 of motor control relay?
Single phase (4)
NO
Is there voltage at terminal 5 of the motor control relay?
Correct wiring between terminal 5 and power supply.
NO
Is there voltage at terminal 8 of motor control relay?
Replace motor control relay.
Correct wiring between L2, L3 and supply.
YES (13)
Is there voltage across terminals L2 & T2 and L3 & T3?
YES (5)
NO
YES
Replace motor control relay.
NO (7)
YES Is there voltage at terminal 6 of motor control relay?
(10)
Is there supply voltage to L1 and L2 of the motor control relay?
NO
Correct wiring between L1, L2 and power supply.
YES (11)
YES
Replace motor control relay.
Correct wiring between terminal 6 of motor control relay and supply.
YES (8)
Is there voltage at terminal 9 of motor control relay?
Is there votlage across L1 & T1 and L2 & T2?
NO
NO
Replace motor control relay.
YES
NO
Note: tests conducted with vend price satisfied and start button pressed.
122
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
59. Motor Will Not Start/Run (continued) (9)
Is there voltage across terminals 1 & 4 of cylinder motor?
NO
Correct wiring between cylinder motor and motor control relay.
YES
Does the cylinder motor run?
NO
Replace cylinder motor.
YES
Motors are operational.
Note: For high voltage three phase supply (380 volts or higher), the cylinder and fan motors are supplied by L1, L2, L3 through the motor relay terminals T1, T2, T3. Make the appropriate adjustments when doing voltage checks.
TMB251S
TMB251S
Please see following 4 pages for wiring diagram information.
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
123
NetMaster Troubleshooting
Motor Will Not Start/Run (Sheet 1 of 2)
4 5 1
2 3
124
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
Motor Will Not Start/Run (Sheet 2 of 2)
7 4 5 8
6
9
TMB271S TMB271S
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
125
NetMaster Troubleshooting
Motor Will Not Start (Sheet 1 of 2)
1
126
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
Motor Will Not Start (Sheet 2 of 2)
12
10
13 11
2 3 6
9
TMB272S
TMB272S
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
127
NetMaster Troubleshooting
60. Unit Will Not Heat (Gas) Note: Tests are conducted with unit running and calling for heat. All voltage checks are referenced to transformer neutral. (1)
(7)
Is there voltage at FS-2 of NetMaster control?
NO
Correct wiring between FS-2 and COM of lint drawer.
YES
Is there voltage at terminal 3 of fan motor centrifugal switch?
NO
Correct wiring between terminal 3 of fan motor centrifugal switch and terminal 4 of motor control relay.
YES Replace NetMaster control.
Replace thermistor. (2)
(8)
NO
Is there voltage at FS-1 of NetMaster control?
Is there voltage across terminals 3 & 5 of fan motor centrifugal switch?
NO
Is the thermistor operational?
YES
NO
(9)
Is there voltage at COM of airflow switch?
NO
Correct wiring between COM of airflow switch and FS-1 of NetMaster control.
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and terminal 5 of fan motor centrifugal switch.
YES
YES
(10)
(4)
YES
Check for proper function of airflow switch and replace if necessary.
NO
Is there voltage across cabinet limit?
YES
Replace cabinet limit.
NO
(5)
Is there voltage at terminal 7 of motor control relay?
Replace fan motor.
YES
(3)
Is there voltage across COM & N.C. terminal of airflow switch?
YES
(11)
NO
Correct wiring between terminal 7 on motor control relay and N.C. terminal on airflow switch.
YES
Is there voltage to the input side of the stove limit?
NO
Correct wiring between stove limit and cabinet limit.
YES
(6)
Is there voltage across terminals 7 & 4 of motor control relay?
YES
Replace motor control relay.
NO
128
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
60. Unit Will Not Heat (Gas) (continued)
(12)
Is there voltage across the stove limit?
YES
Replace the stove limit.
NO
YES Is there a flame?
Unit operational.
NO
(13)
Is there voltage to terminal 2 of the Ignition Control Module (ICM)?
NO
Correct wiring between terminal 2 of ICM and stove limit.
YES Note: Make sure unit is not in a lock out condition.
(14)
Is there voltage at terminal 1 of ICM board?
NO Replace ICM board.
YES
(15)
Is there voltage across the coils of the gas valve?
NO
Correct wiring between gas valve and ICM board.
NO
Replace gas valve coils or complete gas valve.
NO
Replace high voltage ignition cable or igniter.
YES
Is there gas flow through the gas valve?
YES
Does the igniter spark?
YES
TM1857S TMB1857S
Please see following 2 pages for wiring diagram information.
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
129
NetMaster Troubleshooting
Unit Will Not Heat (Gas) (Sheet 1 of 2)
1
7 2
4
5
6
8
3
13 12
10
9
11
130
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
Unit Will Not Heat (Gas) (Sheet 2 of 2)
7
4
5
6
8
13 12
10
14
9
11
15
TMB273S TMB273S
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
131
NetMaster Troubleshooting
61. Unit Will Not Heat (Steam) Single and stacked units.
Note: Tests are conducted with unit running and calling for heat.
Unit Will Not Heat (Steam)
All voltage checks are referenced to transformer neutral.
(1)
(7)
Is there voltage on FS-2 of electronic control?
NO
Correct wiring between FS-2 and COM of lint drawer.
YES Replace electronic control.
Replace thermistor.
(2)
(9)
NO
Correct wiring between COM of airflow switch and FS-1 of electronic control.
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and terminal "5" of fan motor centrifugal switch.
YES (10)
(4)
YES
Check for proper function of airflow switch and replace if necessary.
NO
Is there voltage across cabinet limit?
YES
Replace cabinet limit.
NO
(5)
Is there voltage on terminal 7 of motor control relay?
Replace fan motor.
NO
YES
Is there voltage across COM & N.C. terminal of airflow switch?
YES
YES
(3)
Is there voltage on COM of airflow switch?
Correct wiring between terminal 3 of fan motor centrifugal switch and terminal 4 of motor control relay.
YES
Is there voltage across terminals 3 & 5 of fan motor centrifugal switch?
NO
Is the thermistor operational?
YES
NO
(8)
NO
Is there voltage on FS-1 of electronic control?
Is there voltage on terminal 3 of fan motor centrifugal switch?
(11)
NO
Correct wiring between terminal 7 on motor control relay and N.C. terminal on airflow switch.
YES
Is there voltage to the input side of the stove limit?
NO
Correct wiring between stove limit and cabinet limit.
YES
(6)
Is there voltage across terminals 7 & 4 of motor control relay?
YES
Replace motor control relay.
NO
132
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
61. Unit Will Not Heat (Steam) (continued)
No Heat continued. (12)
Is there voltage across the stove limit?
YES
Replace the stove limit.
NO (13)
Is there voltage across the coil of the steam valve?
NO
Correct wiring between steam valve and stove limit.
YES
Does the steam valve open allowing steam to flow?
No
Replace steam valve.
Unit operational.
TMB253S TMB253S
Please see following 2 pages for wiring diagram information.
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
133
NetMaster Troubleshooting
Unit Will Not Heat (Steam) (Sheet 1 of 2)
1
7 2
4
5
6
3
10
12
9 11
134
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
Unit Will Not Heat (Steam) (Sheet 2 of 2)
7
6
8
13
TMB274S TMB274S
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
135
NetMaster Troubleshooting
62. Unit Will Not Heat (Electric) Single and stacked units.
Note: Tests are conducted with unit running and calling for heat. All voltage checks are referenced to transformer neutral.
(1)
Is there voltage at FS-2 of EDC control?
(7)
NO
Correct wiring between FS-2 and COM of lint panel switch.
YES
Is there voltage at terminal 3 of fan motor centrifugal switch?
NO
Correct wiring between terminal 3 of fan motor centrifugal switch and terminal 13 of motor control relay.
YES Replace EDC control.
Replace thermistor. (2)
(8)
NO
Is there voltage on FS-1 of EDC control?
Is the thermistor operational?
YES
Is there voltage across terminals 3 & 5 of fan motor centrifugal switch?
NO
NO (9)
NO
Correct wiring between COM of airflow switch and FS-1 of EDC control.
YES
Is there voltage to the input side of the cabinet limit?
NO
Correct wiring between cabinet limit and terminal 5 of fan motor centrifugal switch.
YES (10)
(4)
Is there voltage across COM & N.C. terminal of airflow switch?
Replace fan motor.
YES
(3)
Is there voltage at COM of airflow switch?
YES
YES
Check for proper function of airflow switch and replace if necessary.
NO
Is there voltage across cabinet limit?
YES
Replace cabinet limit.
NO
(5)
Is there voltage at terminal 14 of motor control relay?
(11)
NO
Correct wiring between terminal 7 on motor control relay and N.C. terminal on airflow switch.
YES
Is there voltage to the input side of the stove limit?
NO
Correct wiring between stove limit and cabinet limit.
YES
(6)
Is there voltage across terminals 13 & 14 of motor control relay?
YES
Replace motor control relay.
NO
136
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
62. Unit Will Not Heat (Electric) (continued) No Heat continued.
Note: Please make the oppropriate adjustments if your unit is single phase.
(12)
ect wiring en terminal 3 an motor ugal switch rminal 13 of control relay.
Is there voltage across the stove limit?
YES
Replace the stove limit.
NO (13)
Is there voltage across the coil(s) of the heater contactor(s)?
NO
Correct wiring between heater cotactor and stove limit.
NO
Correct wiring between HC1 and Line voltage.
NO
Correct wiring between HC2 and Line voltage.
NO
Check for proper operation of contactors, replace them if necessary.
ce fan motor.
YES (14)
ect wiring en cabinet nd terminal 5 an motor ugal switch.
Is there voltage to the L1, L2 and L3 terminals of HC1?
YES (15)
Is there voltage to the L1, L2 and L3 terminals of HC2? ace cabinet limit. YES (16)(17)(18)
Is there voltage across T1 & T2, T2 & T3 and T3 & T1? rect wiring en stove limit abinet limit.
Unit is operational
YES
Do all elements produce heat?
NO
Check elements for shorts or opens. Check wires between contactors and elements.
YES
TMB1845S TMB1845S
Please see following 2 pages for wiring diagram information.
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
137
NetMaster Troubleshooting
Unit Will Not Heat (Electric) (Sheet 1 of 2)
14
1 16
17
15
18
2
4 3
10
9
138
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70284701
NetMaster Troubleshooting
Unit Will Not Heat (Electric) (Sheet 2 of 2)
7
4
5
6
8
3
13 10
12
9 11
TMB275S TMB275S
70284701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
139