Preview only show first 10 pages with watermark. For full document please download

Ipstones T5-pds.pub

   EMBED


Share

Transcript

Ipstones T5 IP65 surface mounted range of non-corrosive luminaires Mains Luminaire Emergency Luminaire Ipstones is a range of IP65 non-corrosive luminaires featuring a polycarbonate lens and an ABS base. Ideal for use in industrial areas, agricultural buildings and changing rooms, Ipstones are supplied with high frequency control gear as standard and its steel gear tray is retained on straps for ease of installation. Ipstones are supplied less lamps but include suspension eyes and stainless steel mounting brackets to provide the option to suspend the luminaire if required. Catalogue Numbers Mains Luminaires Standard Ipstones luminaire with polycarbonate clips Mains Lumens Weight Cat No Lamp & Mode IPS28/HF 28W T5 high frequency mains 2600 2.00Kg IPS228/HF 2 x 28W T5 high frequency mains 5200 2.10Kg IPS35/HF 35W T5 high frequency mains 3300 2.20Kg IPS235/HF 2 x 35W T5 high frequency mains 6600 2.30Kg IPS49/HF 49W T5 high frequency mains 4300 2.20Kg IPS249/HF 2 x 49W T5 high frequency mains 8600 2.30Kg IPS54/HF 54W T5 high frequency mains 4450 2.00Kg IPS254/HF 2 x 54W T5 high frequency mains 8900 2.10Kg Emergency Luminaires Emergency Weight Lumens Cat No Lamp & Mode IPS28/M3 28W T5 high frequency M3 emergency 650 2.70Kg IPS228/M3* 2 x 28W T5 high frequency M3 emergency 650 2.80Kg IPS35/M3 35W T5 high frequency M3 emergency 860 3.00Kg IPS235/M3* 2 x 35W T5 high frequency M3 emergency 860 3.10Kg IPS49/M3 49W T5 high frequency M3 emergency 890 3.20Kg IPS249/M3* 2 x 49W T5 high frequency M3 emergency 890 3.30Kg * Reverts to 1 lamp in emergency Options Suffix: /AD /SCL /ST Intelligent addressable luminaire Stainless steel clip Digital self-test luminaire Specification Body: Diffuser: Gear-Tray: Charger LED: Lamps: ABS Polycarbonate diffuser Steel construction retained on straps Constant current with green LED for mains healthy and connected battery 28W, 35W, 49W or 54W T5 fluorescent (not supplied) Dimensions B A C Luminaire A (Length) B (Width) C (Height) Clips Required 1 x 28W 1210mm 90mm 80.5mm 10 2 x 28W 1210mm 108mm 85mm 10 1 x 35W 1508.5mm 90mm 80.5mm 12 2 x 35W 1508.5mm 108mm 85mm 12 1 x 49W 1508.5mm 90mm 80.5mm 12 2 x 49W 1508.5mm 108mm 85mm 12 1 x 54W 1210mm 90mm 80.5mm 10 2 x 54W 1210mm 108mm 85mm 10 Technical Information Luminaire data files are available for inclusion into lighting design software packages. Photometric data is available at www.relux.biz and further lighting design information is available from our catalogue or www.orbik.co.uk. Installation Instructions • Connect the mains cable(s), which should be a maximum of 1mm² solid core. • The supply for a non-maintained emergency circuit must be unswitched and is connected to the unswitched input. • The supply to a non-emergency circuit can be switched and is connected to the switched input. • If a single unswitched supply is used for both emergency and normal use a link should be connected between the unswitched supply and switched supply terminals. • Mark the battery pack with date of installation and connect the battery to the module. • For testing purposes a fused spur or keyswitch should be included in the unswitched supply. Orbik Limited, Orbik House, Northgate Way, Aldridge, Walsall, West Midlands, WS9 8UZ Tel: 0870 516 8214 • Fax: 0870 516 8591 • Email: [email protected] www.orbik.co.uk