Bulletin I2136 04/97
SAFEIR Series 30TPS.. PHASE CONTROL SCR
VT
< 1.3V @ 20A
ITSM
= 300A
VRRM 800 to 1600V Description/Features The 30TPS.. SAFE IR series of silicon controlled rectifiers are specifically designed for medium power switching and phase control applications. The glass passivation technology used has reliable operation up to 125°C junction temperature. Typical applications are in input rectification (soft start) and these products are designed to be used with International Rectifier input diodes, switches and output rectifiers which are available in identical package outlines.
Package Outline
Major Ratings and Characteristics Characteristics I T(AV)
Sinusoidal
30TPS..
Units
20
A
30
A
up to 1600
V
300
A
waveform I RMS VRRM/ VDRM I TSM VT
1.3
V
dv/dt
500
V/µs
di/dt
150
A/µs
- 40 to 125
°C
TJ
@ 20 A, TJ = 25°C
TO-247AC
1
30TPS.. SAFEIR Series Bulletin I2136 04/97
Voltage Ratings VRRM/VDRM, max. repetitive peak and off-state voltage
VRSM , maximum non repetitive peak reverse voltage
IRRM/IDRM 125°C
V
V
mA
30TPS08
800
900
10
30TPS12
1200
1300
30TPS16
1600
1700
Part Number
Absolute Maximum Ratings Parameters
30TPS..
Units
IT(AV) Max. Average On-state Current
20
A
IRMS Max. RMS On-state Current
30
ITSM
Conditions @ TC = 95° C, 180° conduction half sine wave
Max. Peak One Cycle Non-Repetitive
250
10ms Sine pulse, rated VRRM applied
Surge Current
300
10ms Sine pulse, no voltage reapplied
I2t
Max. I2 t for Fusing
310
I √t
Max. I √t for Fusing
VTM
Max. On-state Voltage Drop
rt
On-state Slope Resistance
A2 s
442 2
10ms Sine pulse, no voltage reapplied A √s 2
t = 0.1 to 10ms, no voltage reapplied
1.3
V
@ 20A, TJ = 25°C
12
mΩ
VT(TO) Threshold Voltage
1.0
V
IRM/I DM Max.Reverse and Direct
0.5
mA
Leakage Current
10
IH
Max. Holding Current
100
mA
Anode Supply = 6V, Resistive load, Initial IT =1A
IL
Max. Latching Current
200
mA
Anode Supply = 6V, Resistive load
dv/dt Max. Rate of Rise of off-state Voltage
500
V/µs
di/dt
150
A/µs
2
2
10ms Sine pulse, rated VRRM applied
Max. Rate of Rise of turned-on Current
4420
TJ = 125°C
TJ = 25 °C TJ = 125 °C
VR = rated VRRM/ VDRM
30TPS.. SAFEIR Series Bulletin I2136 04/97
Triggering Parameters
30TPS..
Units
8.0
W
PGM Max. Peak Gate Power
Conditions
PG(AV) Max. Average Gate Power
2.0
+ IGM Max. Peak Positive Gate Current
1.5
A
- VGM Max. Peak Negative Gate Voltage
10
V
IGT
Max. Required DC Gate Current
60
mA
to Trigger
45
Anode supply = 6V, resistive load, TJ = 25°C
20
Anode supply = 6V, resistive load, TJ = 125°C
VGT
Max. Required DC Gate Voltage
2.5
to Trigger
2.0
Anode supply = 6V, resistive load, TJ = 25°C
1.0
Anode supply = 6V, resistive load, TJ = 125°C
VGD Max. DC Gate Voltage not to Trigger IGD
V
Anode supply = 6V, resistive load, T J = - 10°C
0.25
Max. DC Gate Current not to Trigger
Anode supply = 6V, resistive load, TJ = - 10°C
TJ = 125°C, VDRM = rated value
2.0
mA
30TPS..
Units
0.9
µs
TJ = 125°C, VDRM = rated value
Switching Parameters tgt
Typical Turn-on Time
trr
Typical Reverse Recovery Time
tq
Typical Turn-off Time
4
Conditions T J = 25°C T J = 125°C
110
Thermal-Mechanical Specifications Parameters
30TPS..
Units °C
TJ
Max. Junction Temperature Range
- 40 to 125
Tstg
Max. Storage Temperature Range
- 40 to 125
RthJC Max. Thermal Resistance Junction
0.8
°C/W
Conditions
DC operation
to Case RthJA Max. Thermal Resistance Junction
40
to Ambient RthCS Max. Thermal Resistance Case
0.2
Mounting surface, smooth and greased
to Heatsink wt
Approximate Weight
T
Mounting Torque
Case Style
6 (0.21)
g (oz.)
Min.
6 (5)
Kg-cm
Max.
12 (10)
(lbf-in)
TO-247AC
Jedec (Modified)
3
30TPS.. SAFEIR Series
30TPS.. Series R thJC (DC) = 0.8 °C/W
120 Conduction Angle
110 30°
60° 90°
100
120° 180°
90 0
5
10
15
20
25
30TPS.. Series R thJC (DC) = 0.8 °C/W
120
110
Conduction Period
100 30° 90
60° 90° 120°
180° DC
80 0
5
10
15
20
25
30
Average On-state Current (A)
Fig. 2 - Current Rating Characteristics
180° 120° 90° 60° 30°
50 40
RMS Limit 30 20
Conduction Angle
30TPS.. Series TJ = 125°C
10 0 5
10
15
20
25
30
Maximum Average On-state Power Loss (W)
Average On-state Current (A)
35
80 DC 180° 120° 90° 60° 30°
60
40 RMS Limit
Conduction Period
20 30TPS.. Series T J = 125°C 0 0
10
20
30
40
50
Average On-state Current (A)
Average On-state Current (A)
Fig. 3 - On-state Power Loss Characteristics
Fig. 4 - On-state Power Loss Characteristics
280 At Any Rated Load Condition And With Rated V RRM Applied Following Surge. 260 Initial TJ = 125°C @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s
240 220 200 180 160 140
30TPS.. Series
120 1
10
100
Number Of Equal Amplitude Half Cycle Current Pulses (N)
Fig. 5 - Maximum Non-Repetitive Surge Current
4
130
Fig. 1 - Current Rating Characteristics 60
0
Maximum Allowable Case Temperature (°C)
130
Peak Half Sine Wave On-state Current (A)
Peak Half Sine Wave On-state Current (A)
Maximum Average On-state Power Loss (W)
Maximum Allowable Case Temperature (°C)
Bulletin I2136 04/97
300 280 260 240
Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Control Of Conduction May Not Be Maintained. Initial T J= 125°C No Voltage Reapplied Rated VRRMReapplied
220 200 180 160 140 120 0.01
30TPS.. Series 0.1
1
Pulse Train Duration (s)
Fig. 6 - Maximum Non-Repetitive Surge Current
30TPS.. SAFEIR Series Bulletin I2136 04/97
Instantaneous On-state Current (A)
1000 T J= 25°C T J= 125°C
100
10
30TPS.. Series 1 0
1
2
3
4
5
6
7
Instantaneous On-state Voltage (V)
Transient Thermal Impedance Z thJC (°C/W)
Fig. 7 - On-state Voltage Drop Characteristics 1
Steady State Value (DC Operation)
D = 0.50 D = 0.33 D = 0.25 D = 0.17 0.1
D = 0.08
Single Pulse 30TPS.. Series 0.01 0.0001
0.001
0.01
0.1
1
Square Wave Pulse Duration (s)
Fig. 8 - Thermal Impedance ZthJC Characteristics Rectangular gate pulse a)Recommended load line for rated di/dt: 10 V, 20 ohms tr = 0.5 µs, tp >= 6 µs b)Recommended load line for <= 30% rated di/dt: 10 V, 65 ohms 10 tr = 1 µs, tp >= 6 µs
(1) PGM = 40 W, tp = 1 ms (2) PGM = 20 W, tp = 2 ms (3) PGM = 8 W, tp = 5 ms (4) PGM = 4 W, tp = 10 ms (a) (b)
VGD IGD 0.1 0.001
TJ = -10 °C
TJ = 125 °C
1
TJ = 25 °C
Instantaneous Gate Voltage (V)
100
(4)
30TPS.. Series 0.01
0.1
(3)
(2)
(1)
Frequency Limited by PG(AV) 1
10
100
Instantaneous Gate Current (A)
Fig. 9 - GateCharacteristics
5
30TPS.. SAFEIR Series Bulletin I2136 04/97
Outline Table
3. 65 (0 .144) 15.90 (0 .626 )
3. 55 (0 .139)
DIA.
15.30 (0 .602 )
5.30 ( 0.20 9) 4.70 ( 0.185)
2.5 ( 0.098) 1.5 ( 0.059)
5.70 ( 0.22 5) 5.30 ( 0.208) 20 .30 ( 0.800) 19 .70 ( 0.775)
5.50 ( 0.217) 4. 50 ( 0.17 7) 1
2
(2 PLC S.)
3
14.80 ( 0.583) 4. 30 (0 .170)
14 .20 (0 .559)
3. 70 (0 .145) 2.20 ( 0.08 7) 1. 40 (0 .056)
2. 40 (0 .095)
MAX .
1. 00 (0 .039)
M AX. 0.80 ( 0.032) 0. 40 (0 .213)
10. 94 ( 0.430) 10 .86 ( 0.427)
Dimensions in millimeters and inches
Ordering Information Table Device Code
30
T
P
S
16
1
2
3
4
5
2 (A)
1
-
Current Rating
2
-
Circuit Configuration:
3
-
Package:
4
-
Type of Silicon: S = Standard Recovery Rectifier
08 = 800V
5
-
Voltage code: Code x 100 = VRRM
12 = 1200V
T = Thyristor
1 (K) (G) 3
T = TO-247
16 = 1600V
6