Preview only show first 10 pages with watermark. For full document please download

Iris - Cooper Industries

   EMBED


Share

Transcript

IRIS DESCRIPTION Recessed lens downlight luminaire with 2-1/4 inch square pinhole aperture utilizing a low voltage MR16 tungstenhalogen lamp. Modular platform can be reconfigured from below the ceiling to accept a broad range of lamp modules and optical elements. Platform is suitable for 2x6 residential or shallow plenum commercial construction. Insulation must be kept 3" from top and sides of housing. Platform + module + element combination supports various lamp beam spreads for desired optical distribution with excellent light control and low aperture brightness. ® Type Catalog # Project Date Comments Prepared By S P E C I F I C AT I O N F E AT U R E S Frame Galvanized steel plaster frame with integral bar hanger receivers. Setscrews provide positive horizontal locking. Collar Matte black steel collar adjusts vertically for 1/2" - 1" thick ceilings and can be rotated +/- 7.5° thru the aperture. Integral gun sights facilitate the use of guide strings or laser lines. Shipped with a paint overspray protector installed in the collar. Lamp Module Installed or removed thru the aperture or from the top and allows lamp orientation at 0°, 90°, 180° and 270° positions. Housing Steel housing painted matte black for a visually dark interior. Removable hinged top allows for top access. All fasteners are captive. Gaskets Closed cell gaskets achieve restrictive airflow requirements without additional caulking. Bar Hangers Captive preinstalled bar hangers adjusts from 8-1/2" to 24" wide; pass thru feature allows shortening without removal. Captive nail penetrates standard and engineered lumber. Mounting flange levels platform with ceiling. Integral clip attaches directly to t-bar. Butterfly Bracket Provides 3" of vertical adjustment and accepts 1/2" EMT, C channel or bar hangers. Pinhole Diecast aluminum flange with square pinhole aperture and integral glass lens. Lens can be removed to facilitate painting to match ceiling finish. Mousetrap type springs pull flange tight to ceiling. Light trap eliminates spill light at edge of flange. May also be installed flush to ceiling using optional plaster lathing ring. Provided with both straight and angle cut parabolic shielding cone, shipped with angle cut version installed. Junction Box (7) 1/2" trade size pry outs, (3) integral clamps for non-metallic cable. Rated for (8) #12 thru branch circuits. Wago® type push wire connectors for field connections. Thermal Protector Self-resetting thermal protector protects against improper lamping and direct contact with insulation. Transformer Integral dual output toroidal magnetic transformer, 120V 50/60Hz input, 12V nominal 75VA maximum output. Separate output for circuits controlled by dimmers compensates for losses in dimmers, improves color temperature and lumen output. Lamp Capsule Ceramic GX5.3 lamp holder mounts to an aluminum heat sink to dissipate heat. Connects to the transformer with electrical quick connects. Accepts 2 lenses, filters or optional lamp snoot. P406TAT MV4MR E4PINSR 75W MR16 Tungsten-Halogen 2-1/4 Inch Square Lens Downlight Cutout = 5-3/16" [132mm] Code Compliance Thermally protected, IP labeled, cULus listed for protected wet locations and ASTM-E283 AIRTITEtm. 5-1/8" [130mm] 14-9/16" [370mm] 8-1/2" [216mm] 4-9/16" [115mm] ENERGY DATA 2-1/4" [57mm] L a m p Wa t t a g e Input Power Input Current (Nominal) ( Wa t t s ) (Amps) 20 21 0.17 35 37 .031 37 39 0.32 42 44 0.37 50 53 0.44 65 69 0.57 71 76 0.63 75 81 0.67 5-3/4"[146mm] E4PINSR 4-15/16"[125mm] E4PINSRRL Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADI120868 2012-07-10 IRIS ® O R D E R I N G I N F O R M AT I O N : C o m p l e t e u n i t c o n s i s t s o f p l a t f o r m , l a m p m o d u l e a n d o p t i c a l e l e m e n t . Example: P406TAT + MV4MR + E4PINSR P l a t fo rm Lamp Module Flange Optical Element A c c e s s o ri e s MV4MR P406TAT = 4" Square Aperture Non-IC Housing MV4MR = MR16 Vertical Lamp Module, 120V Input P406TCP = 4" Square Aperture Non-IC Chicago Plenum Housing [Blank] = Self Flanged, Matte White Flange RL = Rimless Matte White Flange E4PINSR = 2-1/4" Square Aperture Pinhole, Lens LSA16 = Matte black lamp snoot accessory L Series - Filter Media For MR16 lamps (See Accessories specification sheet) RA4X4 = Rimless adapter for 4" elements PLR4X4 = Plaster Lathing Ring (RL Version only) RLA4X4 = Rimless Adapter (RL Version only) P H OTO M E T R I C S P406TAT MV4MR E4PINSR Candlepow er Dis tribution Photom etric R es ults S pacing Criterion = .4 E fficiency = 56.3% 90° Tes t N o. P10592 Platform = P406TAT E lem ent = E 4PIN S R Lum ens = 1100 Lam p = 65M R 16 IR FL25 67 65 63 62 60 59 58 57 56 55 54 67 64 62 60 58 56 55 54 53 52 51 67 63 60 58 56 55 53 52 51 50 49 67 62 59 57 55 53 52 51 50 49 48 Photometric Results Spacing Criterion = .6 Efficiency = 54.3% Test No. P10574 Platform = P406TAT Element = E4PINSR Lumens = 1100 Lamp = 65MR16 IR FL40 65W MR16 90 85 75 65 55 45 35 25 15 5 0 0 0 0 0 0 0 1 20 984 3565 3834 60° 3900 Coefficients of U tilization Ceiling 70 50 30 10 W all % R CR CD 1300 2600 45° 0° 15° Zonal Lum ens S um m ary Vertical Angle 75° 65W MR16 0 1 2 3 4 5 6 7 8 9 10 Candelas Downlight 30° Zone Lumens % Lamp % Luminaire 0- 30 618 56.1 99.8 0- 40 619 56.3 100 0- 60 619 56.3 100 0- 90 619 56.3 100 90-180 0 0 0 0-180 619 56.3 100 Cone of Light 70 50 30 10 50 30 10 50 30 10 50 30 10 0 Zonal cavity m ethod -- floor reflectance = 20% 65 64 62 61 60 58 57 56 55 54 53 65 63 61 59 57 56 55 54 53 52 51 65 62 59 57 56 54 53 52 51 50 49 65 61 58 56 54 53 52 51 50 49 48 62 61 59 58 56 55 54 53 52 51 50 62 60 58 56 55 54 53 52 51 50 49 62 59 57 55 54 53 51 50 50 49 48 60 59 57 56 55 54 53 53 52 51 50 60 58 57 55 54 53 52 51 50 50 49 60 58 56 55 53 52 51 50 49 49 48 57 57 56 55 54 54 53 52 51 51 50 57 56 55 54 53 53 52 51 50 49 49 57 56 55 54 53 52 51 50 49 48 48 56 55 54 53 52 51 50 50 49 48 47 Candelas Candlepower Distribution Downlight 90° Vertical Angle FC B eam Dia 8'0" 60 3.4 9'0" 47 3.8 10'0" 38 4.3 13'0" 23 5.5 15'0" 17 6.4 Zonal Lumens Summary CD 90 0 85 0 75 0 600 60° 65 0 55 0 45 0 Specifications and dimensions subject to change without notice. 45° 35 3 1200 Consult your representative for additional options and finishes. 25 202 15 1164 75° D Zone Lumens % Lamp % Luminaire 0- 30 594 54 99.4 0- 40 597 54.3 100 0- 60 597 54.3 100 0- 90 597 54.3 100 2012-07-10 90-180 0 0 ADI120868 0 6 7 8 9 10 58 57 56 55 54 55 54 53 52 51 53 52 51 50 49 52 51 50 49 48 57 56 55 54 53 55 54 53 52 51 53 52 51 50 49 52 51 50 49 48 54 53 52 51 50 53 52 51 50 49 51 50 50 49 48 53 53 52 51 50 52 51 50 50 49 51 50 49 49 48 53 52 51 51 50 52 51 50 49 49 51 50 49 48 48 50 50 49 48 47 9'0" 47 3.8 10'0" 38 4.3 13'0" 23 15'0" 17 P H OTO M E T R I C S ® 6.4 P406TAT MV4MR E4PINSR Photometric Results Downlight 90° Test No. P10574 Platform = P406TAT Element = E4PINSR Lumens = 1100 Lamp = 65MR16 IR FL40 65W MR16 75° 600 60° 1200 45° 1800 Coefficients of Utilization Ceiling 70 50 30 10 Wall % RCR 65 65 65 65 63 61 60 59 60 58 57 55 58 56 54 52 57 54 51 50 55 52 49 48 53 50 47 46 52 48 46 44 50 46 44 42 49 45 43 41 47 43 41 40 Candelas Candlepower Distribution Spacing Criterion = .6 Efficiency = 54.3% 0 1 2 3 4 5 6 7 8 9 10 5.5 IRIS 0° 15° 30° Zonal Lumens Summary Vertical Angle CD 90 85 75 65 55 45 35 25 15 5 0 0 0 0 0 0 0 3 202 1164 1664 1754 Zone Lumens % Lamp % Luminaire 0- 30 594 54 99.4 0- 40 597 54.3 100 0- 60 597 54.3 100 0- 90 597 54.3 100 90-180 0 0 0 0-180 597 54.3 100 Cone of Light 70 50 30 10 50 30 10 50 30 10 50 30 10 0 Zonal cavity method -- floor reflectance = 20% 63 63 63 63 61 60 59 58 59 58 56 55 58 55 53 52 56 53 51 49 54 51 49 47 52 49 47 46 51 48 45 44 49 46 44 42 48 45 42 41 47 43 41 40 61 61 61 58 57 57 56 55 54 54 52 51 52 50 49 50 48 47 49 47 45 47 45 44 46 44 42 44 42 41 43 41 39 58 58 58 56 56 55 54 53 53 53 51 50 51 50 48 49 48 47 48 46 45 46 45 43 45 43 42 44 42 41 42 41 39 56 56 56 54 54 53 53 52 51 51 50 50 50 49 48 49 47 46 47 46 45 46 44 43 45 43 42 43 42 41 42 40 39 54 53 51 49 47 46 44 43 41 40 39 Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. D FC Beam Dia 8'0" 27 5.0 9'0" 22 5.6 10'0" 18 6.2 13'0" 10 8.1 15'0" 8 9.3 ADI120868 2012-07-10