Transcript
8 TO 12 GHz IMAGE REJECTION OR I/Q MIXERS
MODELS: IR0812LC2A, IRO812LC2B, IRO812LC2C AND IRO812LC2Q FEATURES • RF/LO Coverage ............ 8 to 12 GHz • IF Operation .................. DC to 0.5 GHz • LO Power Range ............ +10 to +13 dBm • Conversion Loss ............. 6.5 dB Typical • Image Rejection ............. 23 dB Typical
MITEQ’s IR series of image rejection mixers is useful for wideband test equipment or in ultra-broadband receivers requiring rejection of an unwanted sideband of signal or noise following a low-noise front-end amplifier. These mixers are also useful as linear single-sideband upconverters by operating in the reverse mode. Higher RF input power versions are available with proportional increases in LO power. Greater image rejection is also available in selected bandwidths, including the IRE series for the 2 to 8 and 6 to 18 GHz bands.
ELECTRICAL SPECIFICATIONS INPUT PARAMETERS
UNITS
MIN.
RF frequency range
GHz
8
RF VSWR (RF = -10 dBm, LO = +10 dBm)
Ratio
LO frequency range
GHz
8
LO power range
dBm
+10
LO VSWR (RF = -10 dBm, LO = +10 dBm)
Ratio
TRANSFER CHARACTERISTICS
CONDITION
2:1 12 +12
UNITS dB
RF < LO
dB
18
23
LO-to-RF isolation
dB
20
30
LO-to-IF isolation
dB
Image rejection (Note 1)
MIN.
dB
TYP.
MAX.
6.5
8
8.5
20
Input power at 1 dB compression
LO = +13 dBm
dBm
+6
Input two-tone third-order intercept point
LO = +13 dBm
dBm
+16
CONDITION IRO812LC2A IRO812LC2B IRO812LC2C
UNITS MHz MHz MHz
MIN. 20 40 100
IRO812LC2Q
MHz
DC
OUTPUT PARAMETERS IF frequency (image rejection mode)
IF frequency (QIFM, I/Q demodulator mode) IF VSWR (RF = -10 dBm, LO = +10 dBm)
Ratio
+13
2.5:1
RF > LO
Single-sideband noise figure
MAX. 12
CONDITION
Conversion loss (Notes 1 and 2)
21
TYP.
TYP.
MAX. 40 80 200 500
1.5:1
IRO812LC2B TYPICAL DATA VSWR (LO = +10 dBm)
IMAGE REJECTION (LO = +10 dBm)
IMAGE REJECTION (dB)
0
VSWR (RATIO)
5:1 4:1 3:1
LO RF
2:1
10 20 30 40 50
1:1 8
8.8
9.6 10.4 FREQUENCY (GHz)
11.2
12
8
8.8
11.2
12
11.2
12
ISOLATION (LO TO RF) (LO = +10 dBm)
0
0
4
20 ISOLATION (dB)
CONVERSION LOSS (dB)
CONVERSION LOSS (IF = 60 MHz, LO = +10 dBm)
9.6 10.4 FREQUENCY (GHz)
8 12
40 60 80
16
100
20 8
8.8
9.6 10.4 FREQUENCY (GHz)
11.2
12
8
MAXIMUM RATINGS Specifications taken at .......................... +25°C Operating temperature .......................... -54 to +85°C Storage temperature ............................ -65 to +125°C AVAILABLE OPTIONS High dynamic range operation Integrated IF amplifier available
8.8
9.6 10.4 FREQUENCY (GHz)
GENERAL NOTES 1. Standard catalog unit aligned and tested for guaranteed RF > LO performance. RF < LO guaranteed performance is available, please contact MITEQ. 2. Add 3 dB to conversion loss for Q option (DC to 500 MHz, I/Q outputs). 3. Guaranteed at midband RF/LO.
OUTLINE DRAWINGS IR0812LC2A, B and C
IR0812LC2Q 2.00
2.00 1.850
.075 .500
RF IN
.250
RFLO
.50
2. MATERIAL: ALUMINUM FINISH: NICKEL
.500 .750
100 Davids Drive IRO102A16B S/N XXXXXX
1.850
.075
.100 DIA. MTG. HOLE (TYP. 2 PLACES)
.50
1.00
Q
.250
.063 .375
TYPE SMA FIELD REPLACEABLE FEMALE CONNECTOR (TYP. 4 PLACES)
NOTES: 1. TERM UNUSED IF PORT INTO 50 OHMS.
QIFM, I/Q DEMODULATOR
22