Preview only show first 10 pages with watermark. For full document please download

Iro812lc2q - Miteq, Inc.

   EMBED


Share

Transcript

8 TO 12 GHz IMAGE REJECTION OR I/Q MIXERS MODELS: IR0812LC2A, IRO812LC2B, IRO812LC2C AND IRO812LC2Q FEATURES • RF/LO Coverage ............ 8 to 12 GHz • IF Operation .................. DC to 0.5 GHz • LO Power Range ............ +10 to +13 dBm • Conversion Loss ............. 6.5 dB Typical • Image Rejection ............. 23 dB Typical MITEQ’s IR series of image rejection mixers is useful for wideband test equipment or in ultra-broadband receivers requiring rejection of an unwanted sideband of signal or noise following a low-noise front-end amplifier. These mixers are also useful as linear single-sideband upconverters by operating in the reverse mode. Higher RF input power versions are available with proportional increases in LO power. Greater image rejection is also available in selected bandwidths, including the IRE series for the 2 to 8 and 6 to 18 GHz bands. ELECTRICAL SPECIFICATIONS INPUT PARAMETERS UNITS MIN. RF frequency range GHz 8 RF VSWR (RF = -10 dBm, LO = +10 dBm) Ratio LO frequency range GHz 8 LO power range dBm +10 LO VSWR (RF = -10 dBm, LO = +10 dBm) Ratio TRANSFER CHARACTERISTICS CONDITION 2:1 12 +12 UNITS dB RF < LO dB 18 23 LO-to-RF isolation dB 20 30 LO-to-IF isolation dB Image rejection (Note 1) MIN. dB TYP. MAX. 6.5 8 8.5 20 Input power at 1 dB compression LO = +13 dBm dBm +6 Input two-tone third-order intercept point LO = +13 dBm dBm +16 CONDITION IRO812LC2A IRO812LC2B IRO812LC2C UNITS MHz MHz MHz MIN. 20 40 100 IRO812LC2Q MHz DC OUTPUT PARAMETERS IF frequency (image rejection mode) IF frequency (QIFM, I/Q demodulator mode) IF VSWR (RF = -10 dBm, LO = +10 dBm) Ratio +13 2.5:1 RF > LO Single-sideband noise figure MAX. 12 CONDITION Conversion loss (Notes 1 and 2) 21 TYP. TYP. MAX. 40 80 200 500 1.5:1 IRO812LC2B TYPICAL DATA VSWR (LO = +10 dBm) IMAGE REJECTION (LO = +10 dBm) IMAGE REJECTION (dB) 0 VSWR (RATIO) 5:1 4:1 3:1 LO RF 2:1 10 20 30 40 50 1:1 8 8.8 9.6 10.4 FREQUENCY (GHz) 11.2 12 8 8.8 11.2 12 11.2 12 ISOLATION (LO TO RF) (LO = +10 dBm) 0 0 4 20 ISOLATION (dB) CONVERSION LOSS (dB) CONVERSION LOSS (IF = 60 MHz, LO = +10 dBm) 9.6 10.4 FREQUENCY (GHz) 8 12 40 60 80 16 100 20 8 8.8 9.6 10.4 FREQUENCY (GHz) 11.2 12 8 MAXIMUM RATINGS Specifications taken at .......................... +25°C Operating temperature .......................... -54 to +85°C Storage temperature ............................ -65 to +125°C AVAILABLE OPTIONS High dynamic range operation Integrated IF amplifier available 8.8 9.6 10.4 FREQUENCY (GHz) GENERAL NOTES 1. Standard catalog unit aligned and tested for guaranteed RF > LO performance. RF < LO guaranteed performance is available, please contact MITEQ. 2. Add 3 dB to conversion loss for Q option (DC to 500 MHz, I/Q outputs). 3. Guaranteed at midband RF/LO. OUTLINE DRAWINGS IR0812LC2A, B and C IR0812LC2Q 2.00 2.00 1.850 .075 .500 RF IN .250 RFLO .50 2. MATERIAL: ALUMINUM FINISH: NICKEL .500 .750 100 Davids Drive IRO102A16B S/N XXXXXX 1.850 .075 .100 DIA. MTG. HOLE (TYP. 2 PLACES) .50 1.00 Q .250 .063 .375 TYPE SMA FIELD REPLACEABLE FEMALE CONNECTOR (TYP. 4 PLACES) NOTES: 1. TERM UNUSED IF PORT INTO 50 OHMS. QIFM, I/Q DEMODULATOR 22