Preview only show first 10 pages with watermark. For full document please download

Irt Eurocard Type Dva-3003 Reclocking Serial Digital Vda

   EMBED


Share

Transcript

I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 9439 7439 Email: [email protected] Web: www.irtelectronics.com IRT Eurocard Type DVA-3003 Reclocking Serial Digital VDA Designed and manufactured in Australia IRT can be found on the Internet at: http://www.irtelectronics.com 3003-dva.ib.doc Page 1 of 9 16/07/2002 DVA-3003 Serial Digital Reclocking VDA Instruction Manual Table of Contents Section Page Operational safety Description Applications Specifications Circuit description Installation Front & rear panel connector diagrams Maintenance & storage Warranty and service Equipment return Drawing index 3 3 3 4 5 6 7 8 8 8 9 This instruction manual applies to DVA-3003 assembly 804224 units later than S/N 9901000 3003-dva.ib.doc Page 2 of 9 16/07/2002 Operational Safety: WARNING Operation of electronic equipment involves the use of voltages and currents that may be dangerous to human life. Note that under certain conditions dangerous potentials may exist in some circuits when power controls are in the OFF position. Maintenance personnel should observe all safety regulations. Do not make any adjustments inside equipment with power ON unless proper precautions are observed. All internal adjustments should only be made by suitably qualified personnel. All operational adjustments are available externally without the need for removing covers or use of extender cards. Description The IRT DVA-3003 is a one in eight out distribution amplifier for SMPTE/EBU serial digital video signals. The module may also be used with 270 Mb/s ASI signals, but due to the polarity consciousness of this format, only four outputs are available. The unit features an input circuit with automatic cable equalisation for Belden 8281 or PFS1/2 coaxial cable and cable driver circuits for eight individually sourced outputs. In addition the DVA-3003 provides reclocking of the input serial digital signal. The amplifier is built in a 3U extended Eurocard 220 mm x 100 mm module designed to mount in the family of Eurocard frames. Applications The DVA-3 is intended to be used where multiple signal outputs are required from equipment with only one output and to provide input cable equalisation for devices not having this feature as most unequalised inputs will only support input signal cable lengths of less than 20 metres. Frequent reclocking of a serial digital signal can lead to increased jitter and unnecessary increased cost, complexity and transit time in circuits. The DVA-3003 is therefore the unit of choice where reclocking of the signal is provided by the destination equipment or otherwise where reclocking is not deemed necessary. The DVA-3003 is the unit of choice where signal deterioration may have occurred and equalisation and reclocking are advised. Where more than eight reclocked outputs are required these can most economically be obtained by a DVA-3003 feeding the required number of DVA-3002’s. 3003-dva.ib.doc Page 3 of 9 16/07/2002 Technical Specifications DVA-3003 Signal input: Number Impedance Return loss 1. 75 Ω. >15 dB 5 MHz to 360 MHz. Signal outputs: Number Type Level Impedance Return loss DC offset 8 SDI or 4 ASI plus one front panel monitoring output. Reclocked. 800 mV ±10% into 75 Ω. 75 Ω. >15 dB 5 MHz to 360 MHz. Nil. Performance: Cable compensation Automatic, better than 300 metres at 270 Mb/s for Belden 8281 or PSF1/2 cable. Auto rate selection of 143, 177, 270 and 360 Mb/s. <1.0 ns, (700 ns typically). <200 ns, (150 ns typically) at 270 Mb/s. Reclocking Rise time Residual jitter Connectors: Signal Alarm BNC 75 Ohms. Krone IDC. Indicators: Power Signal present 270 Mb/s lock 360 Mb/s lock LED (green) for +5 V. LED (green). LED (green). LED (yellow). Alarm: Signal loss Contact closure. Link selectable NO/NC. Power requirement: Voltage Consumption 28 Vac CT (14-0-14 Vac) or ±16 Vdc. 7 VA (<240 mA). Other: Temperature range Mechanical Finish: Front panel Rear assembly Dimensions Standard accessories (supplied with module) 0 - 50° C ambient. Suitable for mounting in IRT 19" rack chassis with input, output and power connections on the rear panel. Grey enamel, silk-screened black lettering & red IRT logo. Detachable silk-screened PCB with direct mount connectors to Eurocard and external signals. 6 HP x 3 U x 220 mm IRT Eurocard. Rear connector assembly. Due to our policy of continuing development, these specifications are subject to change without notice. 3003-dva.ib.doc Page 4 of 9 16/07/2002 Circuit Description DVA-3003: The input circuit consists of U1 a CLC014 adaptive cable equaliser IC, which automatically adapts to equalise any cable length from zero metres to lengths that attenuate the signal by 40dB at 200MHz. This corresponds to 300 metres of Belden 8281 cable. A carrier detect and output mute circuit in the CLC014 is used to mute the output when no signal is present. The CLC014 is insensitive to the pathological patterns that can be present in the serial digital video signal. The output of the CLC014 input stage is coupled to U2 a CLC016 data re-timing PLL with automatic rate selection. The CLC016 is set up for automatic rate selection on the SMPTE 259M/EBU serial data rates of 143,177,270 and 360 Mb/s. As with U1 (the CLC014 input stage) the carrier detect and mute circuit of U2 is used to mute the output when no signal is present. U2 the CLC016 has a low residual output jitter of less than 170 ps p-p at 270 Mb/s and is insensitive to the pathological patterns that can be present in the serial digital video signal. The output of the CLC016 re-timing stage is coupled to cable driver circuits, U3 a CLC007 and U4 a CLC006 to provide the eight isolated outputs from the DVA-3001. Note the cable driver outputs are complementary signals thus signal inversion can occur between the input and four of the outputs of the DVA-3001. IC’s U5 and U6 provide the necessary LED drivers and logic to decode the rate detection indications from U2. LED LD2 is used to indicate the state of the carrier detect circuit, indicating the presence of signal to the re-timing IC U2, and LED LD3 is used to indicate lock of a 270 Mb/s rate signal by U2. Whilst the logic and drivers for indications of 360 Mb/s, PAL and NTSC rates are provided, the LED’s for these functions are not provided on the front panel to avoid confusion. These may be inserted by the user if so desired. The dual AC inputs are rectified by D1 to D4, and then regulated in a LM2575-5 switch mode regulator circuit U7 to provide the +5V operating voltage for the unit. 3003-dva.ib.doc Page 5 of 9 16/07/2002 Installation Handling: The DVA-3003 contains static sensitive devices and proper static free handling precautions should be observed. When individual modules are stored, they should be placed in antistatic bags and proper antistatic procedures should be followed when inserting and removing cards from these bags. Power: Ensure that the voltage selection of the IRT mounting frame used to house the DVA-3003 and the local AC mains supply voltage match and that the correct rating fuse is installed in the mounting frame power supply. Earthing: Chassis earth connection of the equipment mounting frame is via the earth connection on the three pin (IEC) AC mains supply inlet. This is a safety earth and must be connected. Installation: To install the module in a frame please see instructions for the appropriate frame type in the frames/PSU’s manual. The DVA-3003 does not require any adjustment prior to use. There are no external controls on the front panel of the units. The presence of the internal +5 Vdc supply is indicated by the front panel LED (green). 3003-dva.ib.doc Page 6 of 9 16/07/2002 Front & rear panel connector diagrams The following front panel and rear assembly drawings are not to scale and are intended to show relative positions of connectors, indicators and controls only. DVA-3003 DV A-3 0 0 3 1 OUTPUTS 2 3 4 SIGNAL PRESENT 5 6 270 360 7 8 OUTPUT MON ALARM DC 3 2 1 INPUT N140 3003-dva.ib.doc 1 = GND 2 = ALARM CONTACT 3 = GND Page 7 of 9 16/07/2002 Maintenance & storage Maintenance: No regular maintenance is required. Care however should be taken to ensure that all connectors are kept clean and free from contamination of any kind. This is especially important in fibre optic equipment where cleanliness of optical connections is critical to performance. Storage: If the equipment is not to be used for an extended period, it is recommended the whole unit be placed in a sealed plastic bag to prevent dust contamination. In areas of high humidity a suitably sized bag of silica gel should be included to deter corrosion. Where individual circuit cards are stored, they should be placed in antistatic bags. Proper antistatic procedures should be followed when inserting or removing cards from these bags. Warranty & service Equipment is covered by a limited warranty period of three years from date of first delivery unless contrary conditions apply under a particular contract of supply. For situations when “No Fault Found” for repairs, a minimum charge of $A100.00 will apply, whether the equipment is within the warranty period or not. Equipment warranty is limited to faults attributable to defects in original design or manufacture. Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier. Equipment return: Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment. If possible, confirm this by substitution. Before returning equipment contact should be made with IRT or your local agent to determine whether the equipment can be serviced in the field or should be returned for repair. The equipment should be properly packed for return observing antistatic procedures. The following information should accompany the unit to be returned: 1. 2. 3. 4. 5. 6. 7. A fault report should be included indicating the nature of the fault The operating conditions under which the fault initially occurred. Any additional information which may be of assistance in fault location and remedy. A contact name and telephone and fax numbers. Details of payment method for items not covered by warranty. Full return address. For situations when “No Fault Found” for repairs, a minimum charge of $A100.00 will apply, whether the equipment is within the warranty period or not. Please note that all freight charges are the responsibility of the customer. The equipment should be returned to the agent who originally supplied the equipment or, where this is not possible, to IRT direct as follows. Equipment Service IRT Electronics Pty Ltd 26 Hotham Parade ARTARMON N.S.W. 2064 AUSTRALIA Phone: Email: 3003-dva.ib.doc 61 2 9439 3744 [email protected] Page 8 of 9 Fax: 61 2 9439 7439 16/07/2002 Drawing Index Note: Components marked n/c on the diagrams are optional and are not included on standard production units. They are shown to assist with interpretation of additional or optional functions, which may be included or are necessary for factory set-up procedures. Drawing # Sheet # Description 804224 804224 1 2 DVA-3003 input, output and power supply diagram. DVA-3003 reclocking and indicator diagram. 3003-dva.ib.doc Page 9 of 9 16/07/2002 + 1 2 3 L1/RA 10nF 26a,b 25a,b 24a,b 23a,b 22a,b 21a,b 31a,b 30a,b 29a,b 27a,b 28a,b [J1RA/P1] 1 1 C4 100p C6 PCB 804216 ISS.1 J2/RA optional power in (used when fitted to FRU-1030 frame) J2/RA INPUT SK1 4u7 C7 100p C8 FL4 1 1 FL1 7 6 5 4 3 2 1 10uF L4 470nH 10nF C9 10nF C11 C10 +V 2 2 MUTE VEE OEM VCC FL2 3 L3 3 FL3 3 DI AEC- CLC014AJE DI AEC+ 3 VEE DO VCC CD DO VCC U1 MON. O/P F1 4R7 F4 4R7 F3 4R7 F2 4R7 8 9 10 11 12 13 14 2 2 2 2 R1 75 C1 100n R2 100 C3 S1B D4 S1B D3 S1B D2 S1B D1 1 1 1 1 C2 100n R3 120 100n 150 R44 68 R34 JP1 JP2 4 3 2 1 C47 1000uF 804224s2.sch ALARM DDI DDI 1 C48 100uF +V GND +V SDO SDO 5 6 7 8 I L6 +V R18 75 100 O F C27 10nF 2 4 C28 10nF 470nH 100 R33 C42 4u7 R32 U7 LM2575-5.0 VEE IN- IN+ VCC C26 10uF CLC007AJE Q1 Q1 Q0 Q0 U8 Reclocking circuit 4u7 100nF C53 C44 G 3 SK11 EN 5 1 22uH C49 220uF 330uH +5V 10nF C31 R22 100 R21 100 L2 4u7 C32 R23 100 R20 100 +V C43 10nF L1 D7 BAS32 10n C25 R19 75 C41 10nF D5 1N5822 2 + 2 2 1 2 L7 C50 220uF +V 100p C29 8 7 6 5 +V 100p C30 8 7 6 5 2 1 470nH Q0 Q0 IN+ VCC DC LD1 grn R41 820 CLC007AJE VCC IN+ IN- VEE U4 Q0 Q0 Q1 Q1 Q1 IN- CLC007AJE Q1 VEE U3 1 2 3 4 1 2 3 4 1 29-09-1998 68 68 R30 R31 COPYRIGHT 68 68 68 68 68 68 R29 R28 R27 R26 R25 R24 Date: 28-Mar-2001 Revision: 1 ENG. APP. CHECKED K.N. DO NOT COPY NOR DISCLOSE TO ANY THIRD PARTY WITHOUT WRITTEN CONSENT DRAWN 4u7 4u7 C40 4u7 C39 C38 4u7 C37 4u7 C36 4u7 C35 4u7 C34 4u7 C33 DVA-3003 SK10 O/P7 O/P8 O/P5 O/P6 O/P4 O/P3 O/P2 O/P1 - + - + + - + - (OUTPUTS) 804224 Sheet 1 of 4 RECLOCKING SERIAL D.A. Drawing No. Title 3 2 1 L3/RA L2/RA L5/RA L4/RA L6/RA L7/RA L8/RA L9/RA IRT Electronics Pty. Ltd. ARTARMON NSW AUSTRALIA 2064 SCALE N.T.S. A3 SIZE 32b 32a 20a,b 19a,b 18a,b 17a,b 16a,b 15a,b 14a,b 13a,b 12a,b 11a,b 10a,b 9a,b 8a,b 7a,b 6a,b 5a,b 4a,b 3a,b 2a,b 1a,b [P1/J1RA] 2 LD6 LD5 LD4 LD3 grn Q2 BC807 LD2 grn 820 R40 PAL 820 R39 NTSC 820 R38 360 Mb/S 820 R37 270 Mb/S 1 10K 8 C45 10nF 11 8 11 +V 10K U5C 9 6 +V 74HC00 U6D 74HC00 U6C 74HC00 U5D 74HC00 C46 10nF 13 12 10 9 13 12 10 6 3 3 U5B U6A 74HC00 U6B 74HC00 0R0 JP7 74HC00 U5A 74HC00 0R0 R43 820 1 JP3 R42 1 3 R36 SIGNAL PRESENT +V 2 3 1 2 1 5 5 4 2 1 2 1 5 4 1 JP9 0R0 JP10 0R0 Q1 BC846 2 RD1 RD0 JP8 0R0 D8 BAS32 3 8 3 4u7 1 RL1 0R0 JP6 Q3 BC846 2 RL1 3 2 DDI DDI 1 LK1 R15 10K GND +V R35 22K R14 220K C51 100nF C24 10nF +V R6 75 D6 BAS32 C22 C15 1nF 1K R8 100nF +V 2 1 10 1 2 6 5 +VA 16 8 4 2 28 19 100nF C23 R7 75 C12 10n AUTO ACQ/WR SER CARS MUTE CD DDI DDI 10nF C14 +VA 10nF C20 10nF U2 CLC016A VCC +V LK2 VEE 11 7 VEE 1 2 3 ALARM VEE 27 4u7 C19 4u7 L5 470nH C13 C16 100nF C17 82pF 510 R9 RD0 RD1 RTN R3 R2 R1 R0 SCO SCO SDO SDO C18 100p +V VCC C21 VEE 26 VC 12 C52 VC 9 2 1 2 1 2 1 FD 10 +V 2 04-12-00 ECR1154 20 21 18 17 15 14 13 22 23 24 25 1 29-09-1998 COPYRIGHT R17 1K R16 1K 2550 3600 10R 10R Date: K.N. 28-Mar-2001 Revision: 1 ENG. APP. CHECKED DRAWN DO NOT COPY NOR DISCLOSE TO ANY THIRD PARTY WITHOUT WRITTEN CONSENT R13 R12 R11 R10 A3 SIZE 0R0 0R0 DVA-3003 804224 Sheet 2 of 4 RECLOCKING SERIAL D.A. Drawing No. Title IRT Electronics Pty. Ltd. ARTARMON NSW AUSTRALIA 2064 SCALE N.T.S. JP4 JP5 SDO SDO