Transcript
I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 9439 7439 Email:
[email protected] Web: www.irtelectronics.com
IRT Eurocard Type DVA-3003 Reclocking Serial Digital VDA
Designed and manufactured in Australia IRT can be found on the Internet at:
http://www.irtelectronics.com
3003-dva.ib.doc
Page 1 of 9
16/07/2002
DVA-3003 Serial Digital Reclocking VDA
Instruction Manual
Table of Contents Section
Page
Operational safety Description Applications Specifications Circuit description Installation Front & rear panel connector diagrams Maintenance & storage Warranty and service Equipment return Drawing index
3 3 3 4 5 6 7 8 8 8 9
This instruction manual applies to DVA-3003 assembly 804224 units later than S/N 9901000
3003-dva.ib.doc
Page 2 of 9
16/07/2002
Operational Safety: WARNING Operation of electronic equipment involves the use of voltages and currents that may be dangerous to human life. Note that under certain conditions dangerous potentials may exist in some circuits when power controls are in the OFF position. Maintenance personnel should observe all safety regulations. Do not make any adjustments inside equipment with power ON unless proper precautions are observed. All internal adjustments should only be made by suitably qualified personnel. All operational adjustments are available externally without the need for removing covers or use of extender cards.
Description The IRT DVA-3003 is a one in eight out distribution amplifier for SMPTE/EBU serial digital video signals. The module may also be used with 270 Mb/s ASI signals, but due to the polarity consciousness of this format, only four outputs are available. The unit features an input circuit with automatic cable equalisation for Belden 8281 or PFS1/2 coaxial cable and cable driver circuits for eight individually sourced outputs. In addition the DVA-3003 provides reclocking of the input serial digital signal. The amplifier is built in a 3U extended Eurocard 220 mm x 100 mm module designed to mount in the family of Eurocard frames.
Applications The DVA-3 is intended to be used where multiple signal outputs are required from equipment with only one output and to provide input cable equalisation for devices not having this feature as most unequalised inputs will only support input signal cable lengths of less than 20 metres. Frequent reclocking of a serial digital signal can lead to increased jitter and unnecessary increased cost, complexity and transit time in circuits. The DVA-3003 is therefore the unit of choice where reclocking of the signal is provided by the destination equipment or otherwise where reclocking is not deemed necessary. The DVA-3003 is the unit of choice where signal deterioration may have occurred and equalisation and reclocking are advised. Where more than eight reclocked outputs are required these can most economically be obtained by a DVA-3003 feeding the required number of DVA-3002’s.
3003-dva.ib.doc
Page 3 of 9
16/07/2002
Technical Specifications DVA-3003 Signal input: Number Impedance Return loss
1. 75 Ω. >15 dB 5 MHz to 360 MHz.
Signal outputs: Number Type Level Impedance Return loss DC offset
8 SDI or 4 ASI plus one front panel monitoring output. Reclocked. 800 mV ±10% into 75 Ω. 75 Ω. >15 dB 5 MHz to 360 MHz. Nil.
Performance: Cable compensation
Automatic, better than 300 metres at 270 Mb/s for Belden 8281 or PSF1/2 cable. Auto rate selection of 143, 177, 270 and 360 Mb/s. <1.0 ns, (700 ns typically). <200 ns, (150 ns typically) at 270 Mb/s.
Reclocking Rise time Residual jitter
Connectors:
Signal Alarm
BNC 75 Ohms. Krone IDC.
Indicators: Power Signal present 270 Mb/s lock 360 Mb/s lock
LED (green) for +5 V. LED (green). LED (green). LED (yellow).
Alarm: Signal loss
Contact closure. Link selectable NO/NC.
Power requirement: Voltage Consumption
28 Vac CT (14-0-14 Vac) or ±16 Vdc. 7 VA (<240 mA).
Other: Temperature range Mechanical Finish:
Front panel Rear assembly
Dimensions Standard accessories (supplied with module)
0 - 50° C ambient. Suitable for mounting in IRT 19" rack chassis with input, output and power connections on the rear panel. Grey enamel, silk-screened black lettering & red IRT logo. Detachable silk-screened PCB with direct mount connectors to Eurocard and external signals. 6 HP x 3 U x 220 mm IRT Eurocard. Rear connector assembly.
Due to our policy of continuing development, these specifications are subject to change without notice.
3003-dva.ib.doc
Page 4 of 9
16/07/2002
Circuit Description DVA-3003: The input circuit consists of U1 a CLC014 adaptive cable equaliser IC, which automatically adapts to equalise any cable length from zero metres to lengths that attenuate the signal by 40dB at 200MHz. This corresponds to 300 metres of Belden 8281 cable. A carrier detect and output mute circuit in the CLC014 is used to mute the output when no signal is present. The CLC014 is insensitive to the pathological patterns that can be present in the serial digital video signal. The output of the CLC014 input stage is coupled to U2 a CLC016 data re-timing PLL with automatic rate selection. The CLC016 is set up for automatic rate selection on the SMPTE 259M/EBU serial data rates of 143,177,270 and 360 Mb/s. As with U1 (the CLC014 input stage) the carrier detect and mute circuit of U2 is used to mute the output when no signal is present. U2 the CLC016 has a low residual output jitter of less than 170 ps p-p at 270 Mb/s and is insensitive to the pathological patterns that can be present in the serial digital video signal. The output of the CLC016 re-timing stage is coupled to cable driver circuits, U3 a CLC007 and U4 a CLC006 to provide the eight isolated outputs from the DVA-3001. Note the cable driver outputs are complementary signals thus signal inversion can occur between the input and four of the outputs of the DVA-3001. IC’s U5 and U6 provide the necessary LED drivers and logic to decode the rate detection indications from U2. LED LD2 is used to indicate the state of the carrier detect circuit, indicating the presence of signal to the re-timing IC U2, and LED LD3 is used to indicate lock of a 270 Mb/s rate signal by U2. Whilst the logic and drivers for indications of 360 Mb/s, PAL and NTSC rates are provided, the LED’s for these functions are not provided on the front panel to avoid confusion. These may be inserted by the user if so desired. The dual AC inputs are rectified by D1 to D4, and then regulated in a LM2575-5 switch mode regulator circuit U7 to provide the +5V operating voltage for the unit.
3003-dva.ib.doc
Page 5 of 9
16/07/2002
Installation Handling: The DVA-3003 contains static sensitive devices and proper static free handling precautions should be observed. When individual modules are stored, they should be placed in antistatic bags and proper antistatic procedures should be followed when inserting and removing cards from these bags.
Power: Ensure that the voltage selection of the IRT mounting frame used to house the DVA-3003 and the local AC mains supply voltage match and that the correct rating fuse is installed in the mounting frame power supply.
Earthing: Chassis earth connection of the equipment mounting frame is via the earth connection on the three pin (IEC) AC mains supply inlet. This is a safety earth and must be connected.
Installation: To install the module in a frame please see instructions for the appropriate frame type in the frames/PSU’s manual. The DVA-3003 does not require any adjustment prior to use. There are no external controls on the front panel of the units. The presence of the internal +5 Vdc supply is indicated by the front panel LED (green).
3003-dva.ib.doc
Page 6 of 9
16/07/2002
Front & rear panel connector diagrams The following front panel and rear assembly drawings are not to scale and are intended to show relative positions of connectors, indicators and controls only.
DVA-3003
DV A-3 0 0 3
1 OUTPUTS 2 3 4
SIGNAL PRESENT
5 6
270 360
7 8
OUTPUT MON ALARM DC
3 2 1 INPUT
N140
3003-dva.ib.doc
1 = GND 2 = ALARM CONTACT 3 = GND
Page 7 of 9
16/07/2002
Maintenance & storage Maintenance: No regular maintenance is required. Care however should be taken to ensure that all connectors are kept clean and free from contamination of any kind. This is especially important in fibre optic equipment where cleanliness of optical connections is critical to performance.
Storage: If the equipment is not to be used for an extended period, it is recommended the whole unit be placed in a sealed plastic bag to prevent dust contamination. In areas of high humidity a suitably sized bag of silica gel should be included to deter corrosion. Where individual circuit cards are stored, they should be placed in antistatic bags. Proper antistatic procedures should be followed when inserting or removing cards from these bags.
Warranty & service Equipment is covered by a limited warranty period of three years from date of first delivery unless contrary conditions apply under a particular contract of supply. For situations when “No Fault Found” for repairs, a minimum charge of $A100.00 will apply, whether the equipment is within the warranty period or not. Equipment warranty is limited to faults attributable to defects in original design or manufacture. Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier.
Equipment return: Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment. If possible, confirm this by substitution. Before returning equipment contact should be made with IRT or your local agent to determine whether the equipment can be serviced in the field or should be returned for repair. The equipment should be properly packed for return observing antistatic procedures. The following information should accompany the unit to be returned: 1. 2. 3. 4. 5. 6. 7.
A fault report should be included indicating the nature of the fault The operating conditions under which the fault initially occurred. Any additional information which may be of assistance in fault location and remedy. A contact name and telephone and fax numbers. Details of payment method for items not covered by warranty. Full return address. For situations when “No Fault Found” for repairs, a minimum charge of $A100.00 will apply, whether the equipment is within the warranty period or not.
Please note that all freight charges are the responsibility of the customer. The equipment should be returned to the agent who originally supplied the equipment or, where this is not possible, to IRT direct as follows. Equipment Service IRT Electronics Pty Ltd 26 Hotham Parade ARTARMON N.S.W. 2064 AUSTRALIA Phone: Email:
3003-dva.ib.doc
61 2 9439 3744
[email protected]
Page 8 of 9
Fax:
61 2 9439 7439
16/07/2002
Drawing Index Note: Components marked n/c on the diagrams are optional and are not included on standard production units. They are shown to assist with interpretation of additional or optional functions, which may be included or are necessary for factory set-up procedures. Drawing #
Sheet #
Description
804224 804224
1 2
DVA-3003 input, output and power supply diagram. DVA-3003 reclocking and indicator diagram.
3003-dva.ib.doc
Page 9 of 9
16/07/2002
+
1 2 3
L1/RA
10nF
26a,b
25a,b
24a,b
23a,b
22a,b
21a,b
31a,b
30a,b
29a,b
27a,b
28a,b
[J1RA/P1]
1
1
C4 100p
C6
PCB 804216 ISS.1
J2/RA optional power in (used when fitted to FRU-1030 frame)
J2/RA
INPUT SK1
4u7
C7 100p
C8
FL4
1
1
FL1
7
6
5
4
3
2
1
10uF L4 470nH
10nF
C9 10nF
C11
C10
+V
2
2
MUTE
VEE
OEM
VCC
FL2
3
L3
3
FL3
3
DI
AEC-
CLC014AJE
DI
AEC+
3
VEE
DO
VCC
CD
DO
VCC
U1
MON. O/P
F1
4R7
F4
4R7
F3
4R7
F2
4R7
8
9
10
11
12
13
14
2
2
2
2
R1 75
C1 100n
R2 100
C3
S1B
D4
S1B
D3
S1B
D2
S1B
D1
1
1
1
1
C2 100n
R3 120
100n
150
R44
68
R34
JP1
JP2
4
3
2
1
C47 1000uF
804224s2.sch
ALARM
DDI
DDI
1
C48 100uF
+V
GND
+V
SDO
SDO
5
6
7
8
I
L6
+V
R18 75
100
O
F
C27 10nF
2
4
C28 10nF
470nH
100
R33
C42 4u7
R32
U7 LM2575-5.0
VEE
IN-
IN+
VCC
C26 10uF
CLC007AJE
Q1
Q1
Q0
Q0
U8
Reclocking circuit
4u7
100nF
C53
C44
G 3
SK11
EN 5
1
22uH C49 220uF
330uH
+5V
10nF
C31
R22 100
R21 100
L2
4u7
C32
R23 100
R20 100
+V
C43 10nF
L1
D7 BAS32
10n
C25
R19 75
C41 10nF
D5 1N5822
2
+
2
2
1 2
L7
C50 220uF
+V
100p
C29
8
7
6
5
+V
100p
C30
8
7
6
5
2 1
470nH
Q0 Q0
IN+ VCC
DC LD1 grn
R41 820
CLC007AJE
VCC
IN+
IN-
VEE
U4
Q0
Q0
Q1
Q1
Q1
IN-
CLC007AJE
Q1
VEE
U3
1
2
3
4
1
2
3
4
1 29-09-1998
68
68
R30
R31
COPYRIGHT
68
68
68
68
68
68
R29
R28
R27
R26
R25
R24
Date:
28-Mar-2001
Revision: 1
ENG. APP.
CHECKED
K.N.
DO NOT COPY NOR DISCLOSE TO ANY THIRD PARTY WITHOUT WRITTEN CONSENT
DRAWN
4u7
4u7 C40
4u7 C39
C38
4u7
C37
4u7
C36
4u7
C35
4u7
C34
4u7
C33
DVA-3003
SK10
O/P7
O/P8
O/P5
O/P6
O/P4
O/P3
O/P2
O/P1
-
+
-
+
+
-
+
-
(OUTPUTS)
804224
Sheet 1 of 4
RECLOCKING SERIAL D.A. Drawing No.
Title
3 2 1
L3/RA
L2/RA
L5/RA
L4/RA
L6/RA
L7/RA
L8/RA
L9/RA
IRT Electronics Pty. Ltd. ARTARMON NSW AUSTRALIA 2064
SCALE N.T.S.
A3
SIZE
32b
32a
20a,b
19a,b
18a,b
17a,b
16a,b
15a,b
14a,b
13a,b
12a,b
11a,b
10a,b
9a,b
8a,b
7a,b
6a,b
5a,b
4a,b
3a,b
2a,b
1a,b
[P1/J1RA]
2
LD6
LD5
LD4
LD3 grn
Q2 BC807
LD2 grn
820
R40
PAL
820
R39
NTSC
820
R38
360 Mb/S
820
R37
270 Mb/S
1
10K
8
C45 10nF
11
8
11
+V
10K
U5C
9
6
+V
74HC00
U6D
74HC00
U6C
74HC00
U5D
74HC00
C46 10nF
13
12
10
9
13
12
10
6
3
3
U5B
U6A
74HC00
U6B
74HC00
0R0
JP7
74HC00
U5A
74HC00
0R0
R43
820
1
JP3
R42
1
3
R36
SIGNAL PRESENT
+V
2
3
1
2
1
5
5
4
2
1
2
1
5
4
1
JP9 0R0
JP10 0R0
Q1 BC846
2
RD1
RD0
JP8 0R0
D8 BAS32
3 8 3
4u7
1
RL1
0R0
JP6
Q3 BC846
2
RL1
3 2
DDI
DDI
1
LK1
R15 10K
GND
+V
R35
22K
R14
220K C51 100nF
C24 10nF
+V
R6 75
D6 BAS32
C22
C15 1nF
1K
R8
100nF
+V
2 1
10
1 2
6
5
+VA
16
8
4
2
28
19
100nF
C23
R7 75
C12 10n
AUTO
ACQ/WR
SER
CARS
MUTE
CD
DDI
DDI
10nF
C14
+VA
10nF
C20
10nF
U2
CLC016A
VCC
+V
LK2
VEE 11
7 VEE
1
2
3
ALARM
VEE 27
4u7
C19
4u7 L5 470nH
C13
C16
100nF
C17
82pF
510
R9
RD0
RD1
RTN
R3
R2
R1
R0
SCO
SCO
SDO
SDO
C18 100p
+V
VCC
C21
VEE
26 VC 12
C52
VC 9
2
1
2
1
2
1
FD 10
+V
2 04-12-00 ECR1154
20
21
18
17
15
14
13
22
23
24
25
1 29-09-1998
COPYRIGHT
R17 1K
R16 1K
2550
3600
10R
10R
Date:
K.N.
28-Mar-2001
Revision: 1
ENG. APP.
CHECKED
DRAWN
DO NOT COPY NOR DISCLOSE TO ANY THIRD PARTY WITHOUT WRITTEN CONSENT
R13
R12
R11
R10
A3
SIZE
0R0
0R0
DVA-3003
804224
Sheet 2 of 4
RECLOCKING SERIAL D.A. Drawing No.
Title
IRT Electronics Pty. Ltd. ARTARMON NSW AUSTRALIA 2064
SCALE N.T.S.
JP4
JP5
SDO
SDO