Preview only show first 10 pages with watermark. For full document please download

It Was A Wonderful Year And We Appreciate What Our Customers And

   EMBED


Share

Transcript

Dec 5th, 2013 You can get this newsletter by email each month by contacting [email protected] or calling 800-228-0839 Articles Best wishes Improving the Environment with Advanced Technology Happy New year NexSys handout It was a wonderful year and we appreciate what our customers and friends have done to support us during our 40th year of supplying reliable water treatment control systems. Thank You, from the Crew! 2011 AWT Supplier Of the Year Let’s talk in the New Year about NexSys The next generation in reliable controllers. Please remove me from mailing list Lakewood Instruments, LLC 7838 North Faulkner Rd Milwaukee, WI 53224 WWW.LAKEWOODINSTRUMENTS.COM PH: 414.355.2807 Fax: 414.355.3508 ©Copyright 2013 Lakewood Inst, LLC Built-in Ethernet interface Built in LON/Modbus/Bacnet 6 User relays (exp to 10 for Dual Tower or 4 Boilers at the same time) 5.7” Touch Screen Interface removable for remote viewing and access. Every sensor/input up to 1200 ft. (remote mounting and interface via 4 wire twisted pair) Expandable to meet your needs. 15” screen option available Live Color Graphing (Scroll and zoom) "Proud to be the AWT 2011 Supplier of the Year" Interface: Touch Screen display, 5.7” diagonal viewing area. Display Size: 115x86 mm Pixel: 320x240 Color: TFT 65536 Backlight: LED or CCFL Memory: 16 MB Flash, 16 MB RAM Multiple levels of security Screen is accessed by opening the NEMA 4X enclosure front panel. Relay Outputs (Internal): Six relays rated at 120VAC. Relay ratings, 3 AMP per relay, 15 amps total Chemical feed and additional relay programming methods, available selections Feed by percent of blowdown time after blowdown By Setpoint with Percent of time feature as part of spaced feed for setpoint “creep”. Trace chemistry capable with user definable correction factors as part of programming. By makeup totalized gallons By blowdown totalized gallons Percent on time Scheduled feed by time and day Alarm relay-User selected alarms powered output shall be selectable to either feed chemical or to alarm on the following conditions. Inputs: Up to 8 active Sensor inputs (2 TWR Conductivity, pH and ORP, 2 MU Conductivity) can be ordered in various combinations. Water meters- Two Water meter inputs are standard and be factory or field upgradeable for two additional (Total four) water meter inputs Each relay shall be capable of being configured to operate with either of the two flow (digital) input for activation or deactivation Expansion capabilities: The unit will be factory or field upgraded. Additional expansion features include: 4 Additional Fully programmable relays ( NRLY Nodes) 8 Sensor inputs. Combo of Conductivity using NCON and pH or ORP Probes using NpH/ORP Nodes. Requires the purchase of additional probes/Plumbing kits. 8 Additional 4-20MA inputs (2 N420I Nodes) 4 Additional Digital Inputs (NDIG Node) Interface/Communications: The NexSys comes standard with the following system interfaces : LON EIA 709 FTT10, BACnet IP and MODbus TCP (As well as Incorporate DMX outputs). The unit shall comes from the factory with all tables and outputs defined for Information being transmitted , including: The state of any installed relay (On/Off) Water meter readings Conductivity reading Any additional sensor reading (ph, ORP) Any sensor alarms Any Additional 4-20mA input readings Any Additional 4-20 mA output reading Flow condition (and any other digital inputs) Remote Communications: The controller has standard Ethernet capability through and HTML interface that allows 100% access to all features and control parameters of the controller. The remote access allows the user to alter, confirm and manipulate 100% of configurations. All features, parameters, settings and functional requirements to operate, program and monitor the controller are accessible from the touch screen and DO NOT require the use of an external input, PC or device to operate or access. The controller will come standard with the capability to send E-service reports to a subscribed service (user to set up account with a service at their discretion). Controller displays operating values, via a color touch screen, color coded graphs for all sensor and relay operation times and readings with time and date stamps. User shall be able to manipulate graph via zoom and scroll features. Approvals Controller must be UL and CSA Listed (ETL listing is acceptable) NEMA 4X enclosure Power: Transformer power ratings of 120/240 VAC 50/60 Hz.