SAFETY INFORMATION These instructions are applicable to the Salus Controls model stated on the front cover of this manual only, and must not be used with any other make or model. These instructions are intended to apply in the United Kingdom only, and should be followed along with any other statutory obligations - if you are in any doubt, please contact the Salus Controls technical helpline. This accessory must be fitted by a Competent person, and installation must comply with the guidance provided in the current editions of BS7671 (IEE Wiring Regulations) and Part ‘P’ of the Building Regulations. Failure to comply with the requirements of these publications could lead to prosecution. Always isolate the AC Mains supply before opening or removing the unit from the wall or wall box. Please leave these instructions with the end user where they should be kept in a safe place for future reference. PLEASE READ THIS INSTRUCTION MANUAL BEFORE USING THE EQUIPMENT. THIS INSTRUCTION MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
2
iT500 User Reference Manual
CONTENTS 4 INTRODUCTION 4 Features 5 5 5
GETTING STARTED In the Box Optional Equipment
6 INSTALLATION 6 Introduction 10 Installing the iT500RX Receiver 18 Installing the iT500 Thermostat 20 Pairing the iT500 System Units for the First Time 21 Installing the iTG500 Gateway 22 Installing an iT300 Temperature Sensor Transmitter (optional) 23 CONTROLS AND DISPLAY 23 iT500 Thermostat Keypad and Display 25 iT500RX Receiver Controls 26 INSTALLATION PROGRAMMING 26 Installation Setup Mode 26 Entering Installation Setup Mode 27 Selecting the System Configuration 28 Select Heating or Cooling Mode 29 Select Temperature Units 29 Set the Time Zone 31 Turning Daylight Saving Time On or Off
33 PAIRING THE iT500 AND iT300 WITH THE iT500RX 33 Pairing the iT500 Thermostat with the iT500RX Receiver 35 Pairing an iT300 with the iT500RX Receiver (optional) 37 Registering your iT500 Online 40 Download the Smartphone App
69 69 69 70 70 71
TECHNICAL SPECIFICATIONS Operating Environment iT500 Central Thermostat iT500RX Thermostat Receiver iTG500 Gateway iT300 Temperature Sensor Transmitter
43 USER PROGRAMMING 43 Program Times and Setpoint Temperatures 45 Default Program Schedules 46 Control using the PC or Smartphone App 51 Local Control using the iT500TR Thermostat 59 Override Central Heating Zone Settings 61 Override Hot Water Settings 64 Other Overrides 65 Frost Protection 65 Lock and Unlock the Keypad 66 OTHER INFORMATION 66 Low Battery Indication 66 Battery Installation or Replacement 67 Resetting the iT500 Thermostat 68 Firmware Updates
iT500 User Reference Manual
3
INTRODUCTION Thank you for choosing the Salus iT500 Series of Internet enabled programmable heating/cooling controls. We hope that your purchase will give you many years of active and trouble-free service. This equipment can replace an existing domestic central heating and hot water programmable controller and thermostat or can control a completely new installation. It is estimated that using a programmable thermostat can save up to 20% of the energy used by a traditional installation. The equipment can be used without the Gateway unit. In this case the battery powered central Thermostat unit will communicate only with the Thermostat Receiver and cannot be accessed remotely.
Features • Access and control your heating and hot water system via the internet using a smartphone or computer • Programmable using your smartphone or computer • Secure and energy efficient • Three system and display configurations
4
iT500 User Reference Manual
GETTING STARTED In the Box The iT500 Thermostat - replaces your fixed hardwired thermostat and also the timer or programmable part of your heating controller. This unit communicates with the iT500RX Receiver. It can be located anywhere in your home as it is portable and battery powered. Includes: 2 x AA Alkaline Batteries.
The iT500RX Receiver - replaces the switching part of your timer or heating controller that is hardwired to your boiler, pump and 3-way valve. It allows for manual override in the event of failure of your iT500 Thermostat unit.
The iTG500 Gateway - connects to your router and enables you to control your central heating and hot water controls from outside of your home, via a smartphone or computer. Includes: 12V Power Supply and Ethernet Cable
Optional Equipment The iT300TX Temperature Sensor Transmitter - replaces the second hardwired thermostat in a two zone heating system. It can be located in any part of the zone as it is portable and battery powered, can also be wall mounted. Purchased separately.
iT500 User Reference Manual
5
INSTALLATION Introduction The iT500 Thermostat and the iT500RX Receiver are designed to replace the programmer and wired thermostat in a traditional domestic heating arrangement. The equipment can be configured to control the following arrangements: • Heating only, 1 zone • Heating only, 2 zones • Heating plus hot water The system can be remotely controlled, via the internet, by connecting the system to your wireless router.
6
iT500 User Reference Manual
Two Heating Zone Arrangement In this arrangement, the two outputs on the iT500 Thermostat Receiver are used to control two zone heating valves. The temperature in Zone 2 is controlled by the addition of an iT300 Temperature Sensor Transmitter, placed in the zone.
Zone 2 UPSTAIRS U RA RADIATORS
iT300TX T300TX
DOWNSTAIRS DO RADIATORS RA
Boiler e1 Zone iT500TR
iT500RX
iT500 User Reference Manual
7
Heating plus Hot Water Arrangement This is the arrangement for installing an iT500 based control system with a single heating zone and hot water. The iT500RX Receiver is hardwired to the heating and water system components. The iT500 Thermostat is connected wirelessly to the iT500RX Receiver.
Hot
Water Tank
ALL L RADIATORS R
Boiler iT500
8
iT500 User Reference Manual
iT500RX
Connection to the Internet To control the system via your smartphone or a remote computer, the system can optionally be connected to the Internet. The iT500 Thermostat is connected to your existing broadband router, using the iTG500 Gateway.
iTG500
Router Rou
Internet iT500
iT500 User Reference Manual
9
Installing the iT500RX Receiver Replacing an Existing Programmable Controller with the iT500RX Receiver 1. Turn off the electrical power to your appliance. Caution: Ensure that the electrical supply to the appliance has been isolated. Failure to completely isolate the appliance could cause personal injury by electric shock and possible damage to equipment. Remove the cover from the existing programmable controller. 2. Note down the wiring sequence and the cable colours connected to the terminals within the electrical box. 3. Disconnect the wires from the existing programmable controller terminals and remove. Note: Providing the existing programmable controller was mounted using a standard electrical box, the iT500RX Receiver will finally mount back onto this. 4. Loosen the screws at the bottom of the receiver unit, unclip the front of the unit and fit the back of the receiver unit to the wall using the fittings supplied.
10
iT500 User Reference Manual
5. Connect the wires in the electrical box to the terminals of the iT500RX Receiver in the correct sequence. See the wiring diagram later on in this section.
6. Once the wiring has been completed, position the iT500RX Receiver over the electrical box fixing holes. Carefully position any wiring back into the electrical box and secure the iT500RX Receiver using the existing screws.
iT500 User Reference Manual
11
Installing in a New Heating Installation Install a new electrical box and connect the wires as detailed in the wiring diagrams below. Volt Free - Combination Boiler
12
iT500 User Reference Manual
230V Switching - Combination Boiler
iT500 User Reference Manual
13
2 x CH Zones - Volt Free Combination Boiler
14
iT500 User Reference Manual
230 V Switching - S Plan
230 V Switching - S Plan
C
2
230V 230V
230V
BOILER
Permanent 230V 230
iT500 User Reference Manual
15
2 x CH Zones - 230 V Switching Combination Boiler
16
iT500 User Reference Manual
230 V Switching - Y Plan
iT500 User Reference Manual
17
Installing the iT500TR Thermostat The iT500 Thermostat is portable and can be located anywhere, providing it is within range of the iT500RX Receiver. If necessary, install the batteries in the iT500 Thermostat (see Battery Replacement). Fit the wall mounting bracket and clip the Thermostat to the wall, as follows: 1. Attach the wall mounting bracket to a suitable wall using the fittings supplied and the built in level. Note: For best results mount the iT500 Thermostat 1.5m from ground level. 2. After first ensuring that the bracket is secure, clip the iT500 Thermostat into place by aligning the recess on the back of the unit to the bracket and clipping into place. 3. Once clipped into place, ensure the unit is securely seated on the bracket.
18
iT500 User Reference Manual
Alternatively, position the iT500 Thermostat on a flat surface, using the stand provided.
Simply clip the clear stand supplied separately into the back of the unit.
iT500 User Reference Manual
19
Pairing the iT500 System Units for the First Time Once the iT500 Thermostat and the iT500RX Receiver are physically installed, the two units need to be ‘paired’. Pairing allows the two devices to recognise each other and to communicate wirelessly. When powering on the iT500TR Thermostat for the first time, the Thermostat will go through the sequence of screens shown below and automatically try and pair by searching for the strongest signal from an iTG500 Gateway. The units attempt to pair for 10 minutes and during this time, the approximately 20 seconds.
OTA (Over the Air) Software Revision Number
All Display Icons
iT500 Software Revision Number
Home Screen
If the pairing is successful, the
icon is turned on all the time.
If the pairing fails or times out, the
20
icon will flash. Pairing should take
icon will disappear and the system will retry later.
iT500 User Reference Manual
Installing the iTG500 Gateway Connecting to your Router Using an RJ45 cable, connect the Gateway to your router (connected to the internet), connect the supplied power cable to the Gateway and plug it into the 230V power supply. When all the connections are completed, turn on the power supply. This is the first step in enabling you to control your central heating from outside of your home using your mobile phone or a remote computer.
The light on the router will flash red when it is first connected and setting up. When connected to the SALUS Controls Server it will display a constant green light. Note: Check that your router is allowing the gateway access to both incoming and outgoing connections. See your router’s operation manual for details on security and TCP/UDP port settings. 1. The gateway requires a fixed IP address. 2. You require port 80 and 2165 UDP open. 3. Estimated use per month is 20mb.
iT500 User Reference Manual
21
Installing an iT300TX Temperature Sensor Transmitter (optional) The iT300TX Temperature Sensor Transmitter is purchased separately. It is only used if your system supports two central heating zones. The unit is portable and should be located in the area of your home heated by the Zone 2 radiators. 1. Remove the battery cover on the back of the iT300TX. 2. Insert the 2x AAA batteries supplied into the iT300TX. 3. Replace the battery cover.
4. Attach the wall mounting bracket to a suitable wall using the fittings supplied. 5. Align the grooves on the back of the iT300TX and slide onto the bracket. 6. Once in place, ensure the unit is securely seated on the bracket.
22
iT500 User Reference Manual
CONTROLS AND DISPLAY iT500TR Thermostat Keypad and Display Keypad The Thermostat keypad provides six keys for configuring and setting your heating and hot water system. These are virtual keys, areas of the capacitive screen. An internal reset key is also provided for resetting the unit. Short press to confirm selection Display ON Short press to return to previous screen or previous item. In Program Mode, long press to return to home screen without saving. In Manual Override Mode, long press to return to Auto Mode. In Auto Mode, long press to enter OUT mode.
Long press to enter Setting Mode. In Setting Mode, short press to make changes or save changes.
Scroll up/down a menu. Increase/decrease a setting value. Single press advances value by a single digit. Holding rolls value sequentially..
Reset Key (internal) Restores factory presets. In Setting Mode, press and hold to cycle through current settings.
iT500 User Reference Manual
23
Display Indicates unit is in Setting Mode.
Indicates internet connection is active.
Indicates wireless communication is active, transmitting or receiving.
Low battery warning symbol. If flashing, very low battery.
Days of the week, current day only displayed
Indicates that the Holiday override is active.
Indicates that the keypad is locked. Press and together to unlock.
Indicates Frost Protection is active, heating is on.
Clock, with 12/24 hour clock indication.
Temperature indicator, current ambient temperature displayed
Program number, active program displayed
Operation indicator
Zone 1 Heating indicator Heating on indicator
Zone 2 Heating indicator Heating on indicator
Cooling on indicator
Cooling on indicator
Hot Water indicator Hot Water on indicator - qualified below: ON Continuously on 1 On once a day from program 1 ON to program 3 OFF AUTO Running in auto OFF Continuously off
Notes: • Indicators change during programming, becoming displays of selectable options or setpoint indicators. • The
24
and
icons are not used on this model.
iT500 User Reference Manual
iT500RX Thermostat Receiver Controls The iT500RX provides manual control of the system in the event that the wireless connection fails.
Auto - Manual - Off - switches Auto -system controlled by programs in iT500TR Control Thermostat Manual - system continuously on Off - system continuously off
Ch - Aux - Ch/Aux - switches Should be set to match controlled system i.e.: Ch -heating only, 1 zone Aux - heating only, 2 zones Ch/Aux - heating (1 zone) plus hot water
Auto Manual Off
Ch
Aux Ch/Aux
iT500 User Reference Manual
25
INSTALLATION PROGRAMMING Installation Setup Mode The following installation setup options can be set: 1. System Configuration – One Central Heating Zone, Two Central Heating Zones or One Central Heating Zone plus Hot Water. 2. Heating Mode or Cooling mode for the selected System Configuration. 3. Whether temperature is to be displayed in Centigrade or Fahrenheit. 4. The Time Zone setting, for example GMT, GMT+1 etc. 5. Whether or not Daylight Saving is on. The default settings that the iT500 comes with are: • One Central Heating Zone, Heating Mode, temperature in Centigrade, GMT, and DST turned on.)
Entering Installation Setup Mode Unless the display is already on, press the Display ON button screen displayed.
. The display then switches on with the Home
Press and hold down both the Settings button and the Increase button iT500 will then go into Installation Setup mode.
together for two seconds. The
The first setting to be specified is the system configuration. While in Installation Setup mode, if this or any to accept that setting and go other setting is already set the way you want, just press the Confirm button to the next setup option. For example, if the system configuration is already set to the required option, press the Confirm button step through to the Heating or Cooling mode selection option. Press and hold 26
to exit Installation Setup Mode and return to Normal mode at any time.
iT500 User Reference Manual
to
Selecting the System Configuration The first step is to select the system configuration, as follows: 1. When the iT500TX enters Installation Setup mode, the display changes to show the Zone 1 and Hot Water
2. Press the
, Zone 2
icons flashing:
button. The display then changes to show the flashing Zone 1 icon only: This is the indicator for the single central heating zone system configuration. If this is the system configuration you want, press the button again.
3. Press the
and
buttons to cycle through the three different system configurations. This is the indicator for the two central heating zones system configuration. Press the button to select this system configuration.
This is the indicator for the single central heating zone plus hot water system configuration. Press the Confirm button to select this system configuration.
Once the required system configuration has been selected, other installation options may be selected, as described next. iT500 User Reference Manual
27
Select Heating or Cooling Mode You can now select whether heating or cooling is required for the system configuration you selected previously. 1. Once a system configuration has been specified, the system configuration icon is displayed again, but this time with the Heating mode indicator
next to each icon:
or
or
This indicates that heating mode is selected. Press 2. If Cooling mode is required, press the displayed with the Cooling mode icon
or
Press
28
to select Cooling mode.
iT500 User Reference Manual
if this is the mode that you require.
button instead. The system configuration icons are then next to them:
or
Select Temperature Units After Heating or Cooling mode has been selected, you can select the units that temperatures will be displayed in: (°C) or (°F). The screen displays the Centigrade unit by default:
if Centigrade is your preferred choice.
Press
If you prefer Fahrenheit press
Press
or
. The screen then displays the Fahrenheit unit:
.
Set the Time Zone After the temperature units have been selected, you can select the appropriate time zone for your location (see European Time Zones, below).
The display shows the default time zone (0): Press
or
to select the required time zone.
• Press
to select 0, 1, 2, 3, in sequence.
• Press
to select 0, -1
Press
.
iT500 User Reference Manual
29
European Time Zones
30
iT500 User Reference Manual
GMT
GMT +1 Hour
GMT +2 Hours
UK
AUSTRIA
BELARUS*
IRELAND
BELGIUM
BULGARIA
PORTUGAL
BOSNIA
CYPRUS
ICELAND*
CROATIA
ESTONIA
CZECH REPUBLIC
FINLAND
DENMARK
GREECE
FRANCE
LATVIA
GERMANY
LITHUANIA
HOLLAND
MOLDOVA
ITALY
ROMANIA
LUXEMBOURG
RUSSIA
MALTA
TURKEY
NORWAY
UKRAINE
GMT +3 Hours RUSSIA *
POLAND SERBIA SLOVENIA SPAIN SWEDEN SWITZERLAND Note: The countries marked with * do not observe Daylight Saving Time.
iT500 User Reference Manual
31
Turning Daylight Saving Time On or Off After the time zone has been selected, you may choose to turn Daylight Saving Time (DST) on or off.
The screen displays the default DST setting (ON):To set DST on, press To turn DST off, press the
Press
32
to set DST off.
iT500 User Reference Manual
or
.
buttons once. The screen then displays as follows:
PAIRING THE iT500TX WITH THE iT500RX and iT300 Pairing the iT500 Thermostat with the iT500RX Receiver For the iT500 Thermostat and the iT500RX Receiver to communicate wirelessly, they must be “paired” as follows: When the iT500TR Thermostat in Normal mode press and together for two seconds.
The
then flashes and then press
.
Display shows the number “10”. This is the time in minutes that the iT500TR transmits its wireless signal.
Press
to return to home screen. iT500 User Reference Manual
33
Pairing the iT500 Thermostat with the iT500RX Receiver
Using a paper clip, insert into the hole marked SYNC at the bottom of the iT500RX Receiver.
The bottom switch will show a constant red light when the iT500RX. Receiver is ready to pair.
When the iT500RX Receiver and the iT500 Thermostat are powered and paired then the light will be green.
34
iT500 User Reference Manual
Flashing blue light indicates a heat call/Hot water call.
FAILSAFE MODE: In the event of RF signal loss, your system will be switched on for 4 minutes, then off for 11 minutes. If you want to disable FAILSAFE MODE when RF link has been lost then move the slide switch on the iT500RX to either the manual or off position. NOTE: Please go through pairing sequence again if the switch goes orange.
iT500 User Reference Manual
35
Pairing an iT300 with the iT500RX Receiver (optional) The iT300 is purchased separately. It is only be used if your system supports two central heating zones. To pair the iT300 to the receiver, insert a paperclip or similar object into the hole on the left hand side of the iT300 for 2 seconds.
A red light will flash in the top right hand corner of the iT300TX.
With the iT500 Thermostat in Normal mode press two seconds. The following will be displayed.
Press
and
to start sync. count down.
The units will be paired once the count down has finished.
36
iT500 User Reference Manual
together for
Registering your iT500TR Online Before your IT500TR Thermostat can be controlled remotely, it must be registered on the SALUS website. 1. To register your iT500 online, go to the SALUS controls website. www.salus-controls.com . 2. Select your country:
3. Click on the register your iT500 icon on the left hand side of the country’s website:
iT500 User Reference Manual
37
4. Click on REGISTER, then complete the form that is displayed and click REGISTER again.
5. The screen below will then be displayed and a confirmation e-mail will be sent to the e-mail address you entered in the form.
38
iT500 User Reference Manual
6. Now use your username and password to log in, then enter the STA number ( found in the battery compartment on the iT500) and press REGISTER.
7. Your iT500TR will appear as below and is now ready to be controlled or viewed via your PC or Smartphone. Just click on the iT500 icon on your PC.
iT500 User Reference Manual
39
Download the Smartphone App Once you have registered your iT500 online you can download the smartphone App from the iPhone App Store or the Android App Store, depending on which kind of Smartphone you are using. Find the iT500 App on the App Store and click download. The App will automatically download to your Smartphone. Once it is downloaded, you can start controlling your iT500TR Thermostat using the App. 1. Go to the SALUS controls website: www.salus-controls.com. 2. Click on the relevant App Store Icon: 3. Find the SALUS iT500 App in the selected store and download it.
40
iT500 User Reference Manual
Adding or Renaming the iT500 in your Device List Enter your user ID and password. Press LOGIN.
When you first open the iT500 App your iT500TR will appear in the device list and you can start controlling it with your Smartphone.
iT500 User Reference Manual
41
If you add more than one iT500 to your device list, you may wish to rename the iT500 to “DOWNSTAIRS” for example. Click on RENAME and enter a new name.
42
iT500 User Reference Manual
If you forget your password, follow the onscreen instructions.
USER PROGRAMMING Using the PC or Smartphone App remotely, or the iT500 Thermostat unit locally, you can programme in your central heating and hot water settings as required. Before doing this, you should identify your system configuration, as described next.
Identify your System Configuration There are three possible system configurations: • One Central Heating Zone • Two Central Heating Zones • One Central Heating Zone plus Hot Water
iT500 User Reference Manual
43
Note: The system configuration is specified by your installer and should only subsequently be changed by the installer. Once you have identified your system type, you can use your PC or smartphone to fully control your iT500. This can be done using your PC or Smartphone app, or locally on the iT500.
Program Times and Setpoint Temperatures You can specify from which times heating may come on and what temperatures will trigger this (or use the deafult settings described next). For the One Central Heating Zone and Two Central Heating Zone system configurations you have the following options: • Number of programs per day: For each day or day group up to 6 programs can be defined. A program consists of a start time and a temperature setpoint. Start times must be set sequentially, i.e. start time for program 2 must be later than start time for program 1. Failure to set the start times sequentially will result in conflicts and the conflicting start times will have to be re-set. • Temperature setpoint can be set for each program time period. • Days the programs apply to: Days are numbered 1 to 7 where 1 is Monday and 7 is Sunday. Days can be programmed individually or in groups. Groups are as follows; 1-2-3-4-5 (weekdays) plus 6-7 (weekends), or 1-2-3-4-5-6-7 (whole week). In other words you can set up different programs for the weekend compared to weekdays, or have the same programs for the whole week, or have the different programs for every day of the week. For One Central Heating Zone plus Hot Water you have the same program options as above for the central heating zone. For the hot water you have the following options: • Number of programs per day: For each day or group of days (weeks, weekdays and weekends) up to 3 program ON/OFF times can be set. These must be set sequentially, i.e. the OFF time for program 1 must be later than the ON time for program 1, the OFF time for program 3 must be later than the ON time for program 3. Failure to set programs sequentially will result in conflicts which will have to be re-set. • Days the programs apply to: Same as for above.
44
iT500 User Reference Manual
Default Program Schedules Your iT500 Thermostat comes pre-set with these default program schedules. These can be easily changed via the PC or Smartphone App, or locally using the iT500 Thermostat unit if required.
Central Heating PROGRAM
WEEKDAY (1 to 5)
WEEKDAY (6 to 7)
1
Time 6:00am Setpoint Temp 21ºC.
ON
Time 6:00am Setpoint Temp 21ºC
2
Time 8:00am Setpoint Temp 14ºC.
OFF
Time 8:00am Setpoint Temp 14ºC
3
Time 11:00am Setpoint Temp 21ºC.
ON
Time 11:00am Setpoint Temp 21ºC
4
Time 1:00pm Setpoint Temp 14ºC.
OFF
Time 1:00pm Setpoint Temp 14ºC
5
Time 4:00pm Setpoint Temp 21ºC.
ON
Time 4:00pm Setpoint Temp 21ºC
6
Time 9:00pm Setpoint Temp 14ºC.
OFF
Time 9:00pm Setpoint Temp 14ºC
Hot Water PROGRAM
OP
WEEKDAY (1 to 5)
WEEKDAY (6 to 7)
1
ON OFF
6:00am 8:00am
6:00am 8:00am
2
ON OFF
10:00am 12:00pm
10:00am 12:00pm
3
ON OFF
6:00pm 10:00pm
6:00pm 10:00pm
iT500 User Reference Manual
45
Control using the PC or Smartphone App Common Settings and Indicators The interface for all three system configurations for both the PC and the Smartphone app includes the following common settings and indicators: Energy save will use the lowest set temperature on your daily schedule.
Will be displayed when the current program has been manually overridden
Press AUTO to cancel the temporary override of program temperature.
46
iT500 User Reference Manual
One Central Heating Zone The interface for the PC and the Smartphone app for the One Central Heating Zone System Configuration:
Follows weekly schedule
Energy save mode
Heating continuously off
Override program temperature*
Change/view weekly heating schedule Current program
Home
Holiday
Settings
Back
iT500 User Reference Manual
47
Two Central Heating Zones The interface for the PC and the Smartphone app for the Two Central Heating Zones System Configuration:
48
iT500 User Reference Manual
One Central Heating Zone plus Hot Water The interface for the PC and the Smartphone app for the One Central Heating Zone plus Hot Water System Configuration:
iT500 User Reference Manual
49
50
iT500 User Reference Manual
Local Control using the iT500TR Thermostat Local control and user programming using the iT500 Thermostat is carried out with the iT500 in Settings mode. Settings mode is used to: • Set the time (hour/minutes/day/month/year/DST setting) Note: When the iT500 is connected to the internet the time and date are set automatically. • Set program times and setpoints • Review programs
Entering Settings Mode In Normal (Home) mode press for 2 seconds (long press). The unit then enters Settings mode. The icon icon, is displayed when the unit is in Settings mode. When you first enter Settings mode, apart from the only the days of the week and the Zone and Hot Water icons (depending on your System Configuration) are displayed (flashing). For example:
Setting the Time and Date Set the time and date as follows: 1. With the unit in Settings mode, press
to enter Clock Setting mode.
Press the Confirm button
.
iT500 User Reference Manual
51
2. Select 12 hour or 24 hour clock.
The display will show the current setting, 12 hr or 24 hr. If this is the . setting you want, press
Press or to change between 12hr and 24hr. Press confirm the selection.
to
3. The current time is displayed, with the hours flashing:
Press to confirm the hour, or to change it press the required hour is displayed and then press .
or
until
4. After the hour has been set and confirmed, the current time is displayed with the minutes flashing. Press or until the required minute is displayed and then press ..
52
iT500 User Reference Manual
5. The current date is displayed in day / month format. The day of the month will be flashing:
Press to confirm the day, or to change it press required day is displayed and then press .
or
until the
6. After the day has been set and confirmed, the current date is displayed, with the month flashing. Press or until the required month is displayed and press . to confirm the month, or to change it press 7. After the month has been set and confirmed, the current year is displayed, with the year flashing. Press to confirm the year, or to change it press until the required year is displayed and then press .
After
is pressed the unit returns to Normal mode.
iT500 User Reference Manual
53
Setting the Program Schedule for Central Heating Zones In Settings modes you can specify time periods and a desired temperature for each of the time periods. 1. From Normal mode, enter Settings mode by pressing
Press
for 2 seconds.
..
2. If your system configuration is Two Central Heating Zones or One Central Heating Zone plus Hot Water, you now have to select which of these you want to set the schedule for. On the screen, the Zone 1 icon will flash.
If this the zone you want to program for press
..
If you want to program for the other zone (or for hot water), press . The Zone 2 (or hot water) icon will then flash. Press ..
If your system configuration is One Central Heating Zone then that zone is selected automatically. . To exit the programming Note: To step backwards through the programming procedure press procedure and turn to Normal mode press and hold for 2 seconds.
54
iT500 User Reference Manual
3. Next, you must select either the day or group of days that the programs are to be applied to. The days of the week on the display will flash, initial the weekdays. If you want to set up programs for the weekdays group of days, press . Otherwise press . The weekend day numbers will then be displayed flashing ., otherwise press . instead. To program for these press The day numbers for the entire week will then be displayed ., otherwise press . flashing, To program for these press
The individual days of the week will then be displayed flashing, one after the other. Press programs for a day, or press to go to the next day.
to set up
After you have selected which days or day to set up a program schedule for, you ready to set up program 1. The program you are currently setting up is indicated by the number shown in the displayed under the time for example see the number 1 with the white background in the screen example above. 4. The first stage in setting up a program is to specify the start time. The hour setting on the display will or to increase or decrease the hour setting or press to accept the current setting flash. Press and move on to minute setting.
iT500 User Reference Manual
55
5. The minute setting then flashes. Adjust and confirm it in the same way as the hour setting. Each press of or increases or decreases the minute setting by 10 minutes.
6. Next, specify the setpoint temperature. The currently programmed temperture for the program will flash. and buttons to increase or decrease the temperature by 0.5 °C or 0.5 °F, and press to Use the confirm.
7. Programming for program 1 is now complete. The unit then switches to program 2, as indicated by the displayed program number:
8. Repeat steps 4 to 6 for program 2, and then for programs 3 to 6 in turn. 9. If the weekdays group of days was selected, the unit then switches to the weekend group of days so that you can specify the separate programs for the weekend. 56
iT500 User Reference Manual
Day numbers 6 and 7 will be shown on the display: If the weekend group of days was selected, the unit then switches to the weekdays group of days so that you can specify the separate programs for the weekdays. Day numbers 1 to 5 will be shown on the display. One the programs for both the weekdays and weekend have been set up, the unit automatically returns to Normal mode. If the entire week group of days was selected, the unit automatically returns to Normal mode once the 6 programs have been set up. If individual days were selected, the unit automatically returns to Normal mode once the 6 programs for each individual day have been set up.
Setting the Program Schedule for Hot Water 1. From Normal mode, enter Settings mode by pressing 2. On the screen, the Zone 1 icon enter hot water programming.
will flash. Press
for 2 seconds. Then Press
. The Hot Water icon
will then flash. Press
to
3. Select the days or group of days to program for as described in step 3 above.
iT500 User Reference Manual
57
4. You can now enter the On and Off times for program 1. First, enter the On time. ON is shown on the display and the hour setting flashes. Press or to increase or decrease hour setting or press to accept the current setting and move on to minute setting.
5. The minute setting then flashes. Adjust and confirm it in the same way as the hour setting. Each press of or increases or decreases the minute setting by 10 minutes.
6. OFF is then shown on the screen and the hour setting flashes again. Specify the Off time hours and minutes for program 1 in the same way as you did the On time.
7. Programming for program 1 is now complete. The unit then switches to program 2, as indicated by the displayed program number. Repeat steps 4 to 6 for program 2, and then for program 3 in turn. 58
iT500 User Reference Manual
8. Depending on which days you selected to program for you may then be prompted to program for another group of days or individual days as described in step 9 above. Hot water programming is then complete and the unit automatically returns to Normal mode.
Override Central Heating Zone Settings Override Setpoint Temperatures for a Central Heating Zone To temporarily override the setpoint temperatures, in other words to set the central heating to come on and maintain a temperature you choose at the time, instead of according to its current program, carry out the following steps: 1. If your system configuration is One Central Heating Zone, or if it is Two Central Heating Zones and you want to override the current setpoint temperature for Zone 1, or if it is One Central Heating Zone plus Hot or . Water, simply press If your system configuration is Two Central Heating Zones and you want to override the current setpoint or . temperature for Zone 2, press to switch to Zone 2, and then press 2. The setpoint temperature of the current program is then displayed:
3. Press Press
or
. to increase or decrease the temporary setpoint temperature.
to cancel setting the override and return to the Home display.
iT500 User Reference Manual
59
4. To confirm the override, press
. The Home screen is then displayed again.
Note that the “AUTO” status indicator is no longer displayed in the bottom-right hand corner of the screen, and the icon is displayed in the top-left corner, indicating that an override has been set.
Temporary setpoints are cancelled at the end of the program in which they have been set. To turn off an . override before then, press and hold
Turn Off Central Heating for a Central Heating Zone Central heating for a zone can be turned off, as follows: 1. If your system configuration is One Central Heating Zone, or if it is Two Central Heating Zones and you want to turn off heating for Zone 1, or if it is One Central Heating Zone plus Hot Water, simply press and together. If your system configuration is Two Central Heating Zones and you want to turn off heating for Zone 2, and together. press to switch to Zone 2, and then press 2. The screen then displays the icon for the selected zone, plus the AUTO indicator, which will be flashing:
60
iT500 User Reference Manual
3. Press
or
. The AUTO indicator will be replaced by the OFF indicator:
Press
.
4. The Home screen will then be displayed again, with the OFF indicator displayed to show that central heating for the zone has been turned off. To turn programmed central heating for a zone back on, follow the above procedure, and reset the unit to or . buttons. AUTO from OFF using the
Override Hot Water Settings Turn On Hot Water for Set Number of Hours If your system configuration is One Central Heating Zone plus Hot Water you can turn on hot water at any time, for 1 to 9 hours, overriding the hot water programming. 1. In Normal mode, press
to switch to the Hot Water settings:
iT500 User Reference Manual
61
2. Press
or
. The hot water override setting is displayed:
3. By default, this will be h0, meaning 0 hours, indicating that an override has not been set. To set an until the required number of hours for the override is override and turn on the hot water, press displayed. For example:
Press
.
4. The hot water settings are then displayed again with the override setting shown. Note that the “AUTO” status indicator is no longer displayed in the bottom-right hand corner of the screen, and the icon is displayed in the top-left corner, indicating that an override has been set.
At the end of the override period the unit returns to its program schedule. To turn off a hot water override at any time, follow the above procedure and set the hours back to 0.
62
iT500 User Reference Manual
Turn Hot Water On Permanently, or On Once, or Off If your system configuration is One Central Heating Zone plus Hot Water, apart from turning on hot water for a set number of hours as described above, the following program overrides may also be set: • Turn hot water on all the time • Turn hot water on for a single period of the day, from the ON time of program 1 to the OFF time of Program 3 • Turn off hot water completely To turn on any of these overrides: 1. In Normal mode, press
and 2. Press be flashing:
3. Press
or
to switch to the Hot Water settings.
together. The screen then displays the hot water icon, plus the AUTO indicator, which will
. to scroll through the override settings:
• To turn hot water on all time, scroll until the ON indicator is displayed instead of AUTO • To turn on hot water for a single period, scroll until the 1 indicator is displayed • To turn off hot water, scroll until the OFF indicator is displayed. iT500 User Reference Manual
63
For example:
. The Home screen will then be displayed again, with the 4. When the required override is selected, press relevant indicator displayed to show that central heating for the zone has been turned off. To turn programmed hot water on, follow the above procedure, and reset the unit to AUTO from ON, 1 or OFF or . buttons and press . using the
Other Overrides Two additional types of override can be set: • Energy Save override, which will use the lowest set temperature on your daily schedule. • Holiday override, which for a set period of time changes the central heating setpoint to the same as the Frost Protection setpoint (see below). If Frost Protection is switched on, this may also result in the normal programming being overridden, as explained below. If the Energy Save override is on, the If the Holiday override is on, the
is displayed on the iT500 screen. icon is displayed.
Both these overrides can only be set using the Smartphone App or via the PC, however they may be turned off locally if required. To cancel either of these overrides, press Press
64
to de-activate the override. The relevant icon flashes.
to confirm switching off the override.
iT500 User Reference Manual
Frost Protection The Frost Protection function protects your home from damage due to very low temperatures, e.g. frozen pipes. Frost protection automatically turns on heating for Central Heating when the temperature drops below the selected setpoint temperature. Frost Protection automatically turns Central heating off when the measured temperature is higher than the Frost Protection setpoint. Frost Protection can only be configured and activated using the Smartphone App or via the web app. When Frost Protection is activated, the
icon is displayed on the iT500 screen
In frost mode, you have a range from 1.5 degrees to 9 degrees to select from using the Smartphone or web app.
Lock and Unlock the Keypad To lock the kepypad so that the buttons are disabled, press displayed on the screen: To unlock the keypad, press the
and
and
together. The
icon is then
buttons together again.
iT500 User Reference Manual
65
OTHER INFORMATION Low Battery Indication The iT500 Thermostat is battery powered. The system monitors the battery voltage and provides a 2-stage low battery warning system. When the 1st stage low voltage is reached, the When the 2nd stage low voltage is reached, the
icon is displayed. icon starts to flash.
Change the batteries as soon as possible.
Battery Installation or Replacement 1. To install or replace the batteries in the iT500 Thermostat, remove the battery cover from the base of the iT500 Thermostat. Note: Dispose of replaced batteries at a suitable recycling facility. 2. With the unit face down, insert the first battery supplied into the right hand side of the base of the iT500 Thermostat.
66
iT500 User Reference Manual
3. Insert the second battery supplied into the left hand side of the base of the iT500 Thermostat. 4. Ensure the batteries are fitted securely in the base of the iT500 Thermostat. 5. Replace the battery cover to the base of the iT500 Thermostat.
Note: The serial number of the iT500 Thermostat is on a label in the back of the battery compartment.
Resetting the iT500TR Thermostat To return your iT500 Thermostat to its factory settings insert a paper clip, or similar blunt object, into the hole at the bottom of the stand socket on the back of the unit, for XX seconds. Note: If the stand is attached this must be removed to access the reset hole.
iT500 User Reference Manual
67
Firmware Updates The firmware used by iT500 Thermostats is periodically updated by SALUS. To install these updates on your iT500, go to the website and follow the onscreen instructions. For example: The firmware on your unit will then be updated using OTA (Over The Air) technology.
Home
Devices
My Account
Logout
The display will flash 1, 2, 3, 4, 5, 6 to show that an update is in progress, starting with 1 and rising to 6:
Home
© Salus Controls 2012
Devices
Privacy Policy
My Account
Disclaimer
Logout
Site Map
Warning: While the update is in progres, do not exit the webpage or disconnect the device, as this will cancel the update.
DO NOT: Remove the batteries while the update is in progress as this will result in your iT500TR being permanantly unusable. 68
iT500 User Reference Manual
© Salus Controls 2012
Privacy Policy
Disclaimer
Site Map
TECHNICAL SPECIFICATIONS Operating Environment Temperature
0 - 50 °C
Humidity
5 - 95%
iT500 Central Thermostat Weight
170 g (not including batteries)
Dimensions
128.0 x 93.0 x 28.2mm
Mounting
Flat surface or wall
Channels
x 2 - Central Heating 1 and Central Heating 2 / Hot Water
RF Module
Two way 868MHz 1 Way Receiver / Transmitter
OTA
Over the Air technology
Date Format
Days of the week 1-2-3-4-5-6-7
Time Format
12hr/24hr – 12hr is the default
Temperature
°C/°F – the default is °C -0.25 to 45.25°C range, resolution is 0.25°C 1 – 9°C Frost Protection range
Heat Control
Heating mode is default In Cooling mode Frost Protection is disabled
Programmer
Heating Zones 1 and 2: whole week, weekdays only, weekends only or individual days selectable Hot Water: On/Off - days selectable as above Frost Protection: always on
Power Supply
2 off AA alkaline batteries LR6 12 months life Flashing low battery indicator
iT500 User Reference Manual
69
iT500RX Thermostat Receiver Weight
210g
Dimensions
144.6mm x 99.5mm x 34.8mm
Mounting
Flat surface
Channels
x 2 - Heating Zone 1 and Heating Zone 2 / Hot Water
RF Module
One way 868MHz Receiver 30 meters minimum range
Power Supply
x 2 AA alkaline batteries LR6 12 months life Flashing low battery indicator
iTG500 Gateway Weight
50g (not including adaptor)
Dimensions
91 x 38.5 x 25.5 mm
Mounting
Flat surface
RF Module
One way 868MHz Transmitter / Receiver 30 meters minimum range External Antenna
OTA
Over the Air technology
Internet Connection
RJ45 connector to router
Power Supply
Input: 230VAC – 50Hz Output: 5VDC – 300mA Cable: 1 meter (Black) Plug: AC power
70
iT500 User Reference Manual
iT300 Temperature Sensor Transmitter Weight
70 g (not including batteries)
Dimensions
75.5mm x 75.5 mm x 22.5 mm
Mounting
Flat surface
Channels
Transmits to Heating Zone 2 only
RF Module
One way 868MHz Receiver 30 meters minimum range
Power Supply
2 off AA alkaline batteries LR6 12 months life Flashing low battery indicator
iT500 User Reference Manual
71
Waste Electrical and Electronic Equipment Directive (WEEE Directive) This symbol on the product or on its packaging indicates that this product should not be treated as household waste. Instead it should be handed over to a suitable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local council office, your household waste disposal service or the shop where you purchased the product.
CE Certificate of Conformance
72
iT500 User Reference Manual
Warranty SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of two years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
Customer Name: ................................................................................................................................................................... Customer Address: .............................................................................................................................................................. ............................................................................... Post Code: ................................................................................................ Tel No: ........................................................ Email: .................................................................................................................
Engineer’s Company: .......................................................................................................................................................... Tel No: ......................................................... Email: ................................................................................................................ Installation Date: .................................................................................................................................................................. Engineer’s Name: .................................................................................................................................................................. Engineer’s Signature: .........................................................................................................................................................
iT500 User Reference Manual
73