J009jnndch/aa Submittal A Fjm Series, Mini 4-way Cassette Samsung

   EMBED


Share

Transcript

SUBMITTAL AJ009JNNDCH/AA Samsung FJM Series, Mini 4-Way Cassette Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Page 1 of 2 Construction Specifications Cooling (Btu/h) 8,900 Heating (Btu/h) 9,900 Nominal Capacity Performance C Condensate Pints/Hour Voltage (ø/V/Hz) 1.7 1 / 208-230 / 60 Power Nominal Running Current (A) Type Fan Airflow Turbo (1) Type Motor CFM FLA / Output L/M/H Type Refrigerant Unit Dimensions Sound Level Accessories • Electro-static, washable, pleated filters as standard (included with fascia panel) 0.17A / 24 W • The unit shall ship with a fascia panel (when ordered as a system) 245 / 290 / 350 • Built in condensate pump and check valve with maximum 29" lift R410A • Knock-out for outside air capability (with booster fan connection) Liquid (flare) Inches 1/4 Suction (flare) Inches 3/8 Drain Inches OD 1 1/4, ID 1 WXHXD Inches 22 5/8 X 10 X 22 5/8 Weight lbs. 24.25 PC4SUSMB Model Number Fascia Panel BLDC (1) Electronic Expansion Valve (at outdoor unit) Control Method Piping Connections 0.51 LXWXH Inches 26 1/2 X 1 3/8 X 26 1/2 Weight lbs. 8 L/H dB 27 / 33 • Fascia panel shall have LED indicator lights, IR receiver, and 4 motorized louvers with independent control. • High-voltage terminal block temperature sensor to disable unit in the event overheating of power connection. • The indoor unit shall be powered by the outdoor unit Construction Galvanized steel frame with HIPS chassis and fascia panel certified to UL94 V0. Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube Indoor Fan Indoor fan is a single turbo type Three fan speed settings and auto setting External Contact Control MIM-B14 Motion Occupancy Sensor MCR-SMA Wireless Remote Controller MR-EH00U Premium Wired Controller W/Scheduling MWR-WE10 Standard Wired Controller MWR-WH02 Line sets - insulated and flared, interconnect cables included 25' - ILS2506 The system shall integrate with the Samsung Controls Solution. 50' - ILS5006 Compatibility Will only operate with Samsung outdoor unit model numbers: AJ020JCJ2CH/AA, AJ024JCJ3CH/AA, AJ036JCJ5CH/AA. Safety Certifications ETL & ETLc Controls Control signal shall be a DDC type signal Interconnect control wire between outdoor and indoor shall be 16AWG X 2 shielded Controls shall integrate with a BMS system Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95 ⁰F DB, 75⁰F WB. Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47 ⁰F DB, 43⁰F WB. Samsung and Quietside maintains a policy of ongoing development, specifications are subject to change without notice. QS-FJM-022015A www.Quietside.com 888-699-6067 Page 2 of 2 SUBMITTAL AJ009JNNDCH/AA Samsung FJM Series, Mini 4-Way Cassette 11 13/16" 4 3/4" 5 7/8" 2 1 10 19/32" 4 9 13/16" 26 3/8" 6 13/16" 1 9/16" 6 7 5 1/8" 6 15/16" 7 11/16" 15" 26 3/8" Ø 4 7/16" 1 5/8" 8 7/8" 2 1/4" 15" 1 7/8" 3 22 5/8" 5 10" 11 5/8" PC4SUSMEN Panel 1 7/8" 22 5/8" 1 7/8" 23 - 24 13/16" Ceiling Opening 23 - 24 13/16" Ceiling Opening 19 11/16" Suspension Point 19 11/16" Suspension Point re or mo m(59”) 1500 m 15 00 m m (59 ”) or m or e Name No. 15 00 m m (59 ”) or m or e 1 2 3 4 5 6 7 Liquid Pipe Connection Gas Pipe Connection Drain Pipe Connection Conduit for Power & Communication Wiring Air Inlet Grille Air Outlet Louver Fresh Air Intake re or mo m(59”) 1500 m Proper clearance must be maintained around unit for proper operation. www.Quietside.com Description Ø 1/4" Flare Ø 3/8" Flare OD 1 1/4", ID 1" Ø 4 7/16" 1 7/8"