Transcript
SUBMITTAL AJ009JNNDCH/AA Samsung FJM Series, Mini 4-Way Cassette
Job Name Purchaser Submitted to Unit Designation
Location Engineer Reference Schedule #
Approval
Page 1 of 2
Construction
Specifications Cooling (Btu/h)
8,900
Heating (Btu/h)
9,900
Nominal Capacity Performance C Condensate
Pints/Hour
Voltage (ø/V/Hz)
1.7 1 / 208-230 / 60
Power Nominal Running Current (A) Type Fan
Airflow
Turbo (1) Type
Motor CFM
FLA / Output
L/M/H
Type Refrigerant
Unit Dimensions
Sound Level
Accessories
• Electro-static, washable, pleated filters as standard (included with fascia panel)
0.17A / 24 W
• The unit shall ship with a fascia panel (when ordered as a system)
245 / 290 / 350
• Built in condensate pump and check valve with maximum 29" lift
R410A
• Knock-out for outside air capability (with booster fan connection)
Liquid (flare)
Inches
1/4
Suction (flare)
Inches
3/8
Drain
Inches
OD 1 1/4, ID 1
WXHXD
Inches
22 5/8 X 10 X 22 5/8
Weight
lbs.
24.25 PC4SUSMB
Model Number Fascia Panel
BLDC (1)
Electronic Expansion Valve (at outdoor unit)
Control Method
Piping Connections
0.51
LXWXH
Inches
26 1/2 X 1 3/8 X 26 1/2
Weight
lbs.
8
L/H
dB
27 / 33
• Fascia panel shall have LED indicator lights, IR receiver, and 4 motorized louvers with independent control. • High-voltage terminal block temperature sensor to disable unit in the event overheating of power connection. • The indoor unit shall be powered by the outdoor unit Construction Galvanized steel frame with HIPS chassis and fascia panel certified to UL94 V0. Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube Indoor Fan Indoor fan is a single turbo type Three fan speed settings and auto setting
External Contact Control
MIM-B14
Motion Occupancy Sensor
MCR-SMA
Wireless Remote Controller
MR-EH00U
Premium Wired Controller W/Scheduling
MWR-WE10
Standard Wired Controller
MWR-WH02
Line sets - insulated and flared, interconnect cables included
25' - ILS2506
The system shall integrate with the Samsung Controls Solution.
50' - ILS5006
Compatibility Will only operate with Samsung outdoor unit model numbers: AJ020JCJ2CH/AA, AJ024JCJ3CH/AA, AJ036JCJ5CH/AA.
Safety Certifications
ETL & ETLc
Controls Control signal shall be a DDC type signal Interconnect control wire between outdoor and indoor shall be 16AWG X 2 shielded Controls shall integrate with a BMS system
Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95 ⁰F DB, 75⁰F WB. Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47 ⁰F DB, 43⁰F WB. Samsung and Quietside maintains a policy of ongoing development, specifications are subject to change without notice.
QS-FJM-022015A
www.Quietside.com 888-699-6067
Page 2 of 2
SUBMITTAL AJ009JNNDCH/AA Samsung FJM Series, Mini 4-Way Cassette 11 13/16"
4 3/4"
5 7/8"
2 1
10 19/32"
4
9 13/16"
26 3/8"
6 13/16"
1 9/16"
6
7
5 1/8"
6 15/16"
7 11/16" 15"
26 3/8"
Ø 4 7/16"
1 5/8"
8 7/8"
2 1/4"
15"
1 7/8"
3
22 5/8"
5
10"
11 5/8"
PC4SUSMEN Panel
1 7/8"
22 5/8"
1 7/8"
23 - 24 13/16" Ceiling Opening
23 - 24 13/16" Ceiling Opening
19 11/16" Suspension Point
19 11/16" Suspension Point
re or mo m(59”) 1500 m
15 00 m m (59 ”) or m or e
Name
No.
15 00 m m (59 ”) or m or e
1 2 3 4 5 6 7
Liquid Pipe Connection Gas Pipe Connection Drain Pipe Connection Conduit for Power & Communication Wiring Air Inlet Grille Air Outlet Louver Fresh Air Intake
re or mo m(59”) 1500 m
Proper clearance must be maintained around unit for proper operation.
www.Quietside.com
Description Ø 1/4" Flare Ø 3/8" Flare OD 1 1/4", ID 1"
Ø 4 7/16"
1 7/8"