Preview only show first 10 pages with watermark. For full document please download

Japanese Residential Detector Datasheet

   EMBED


Share

Transcript

Residential Fire Alarms Peace with love to protect family 10-year e voic l a Re Battery life Systemsensor Electronic co., ltd produces this series of residential alarms with high sensitivity and good stability feature. It can send out the sounder alarm signal. The battery for this product can be used 10 years. The product can be operate easily and have the better reliability to protect our life and property safety. Product Feature ◆ Two installation types, ceiling and wall hanging. Convenient installation and easy operation ◆ Real voice for alarm The alarm is designed for protecting you and your family safe. It supplies two convenient installation types for ceiling and wall hanging and also has the keyboard and the draught rope manual action functions for you to choose the the best way according to your needs. ◆ With manual testing function Beautiful and generous artwork ◆ with low-power microprocessor ◆10 years battery life ◆ stability and reliabilty performance ◆ with advanced technology ◆ unique structure to prevent the dust and insect entering The alarms with the unique materials configuration adopt the domestic advanced technology, and is based on foreign advanced market experience to make this series product have the beautiful and delicatee appearance. Ultra-low power consumption The alarms adopt the ultra-low-power microprocessor, and the lithium battery used for the product can supply the power for more than 10 years at the normal operating environment. Stability and reliable performance Systemsensor as the world's top 500 strategic business unit of Honeywell.,has been in the fire and industrial fire civilian leadership. As the greatest fire detector manufacturer in the world.,we have obtained the supporting operations all over the world, and we can guarantee to provide you with the perfect and timely service for everywhere in the world. Introducting from the foreign advanced process, management systems and quality management system, System sensor always committed to research and develope the advanced technology and high-quality products. Our quality assurance capacity is the first-class, and the advanced manufacturing equipment and high-performance testing equipment to ensure each shipping product with high quality and be complid with the international quality system certification. The alarms are learned from foreign advanced production concepts, integrated a wealth of R & D experience in the field of fire alarm and developed a highly sensitive residential fire alarms. At the same time, it provides the convenient and reliable protection for you and your family in adopting the rigorous test methods to reduce the fault alarm rate. Perfect function The series of fire alarm equipment is designed specifically for residential construction. It alarms can be observed directly, and the simple test and convenient reset methods and the humanized designs are very suitable to meet the household requirements. Recognized certification The product is complied with China National Supervision and Test centre for Fire Electronic Product Quality and examination of Japan Association of Fire certified products. Product introduction The role of some components Alarm Silence button / indicator (red) (normal: off). Mounting plate Draught rope hole HS-JV5 Alarm Silence button Alarm parts Thermal detecting parts Draught rope Loudspeaker Thermal sensors detecting part. Self-checking Silence the alarm sound d Flashing at alarm Send out and magnified the alarm sounds sensor To detect the fire when it senses the heat Alarm Silence button Model HS-JV5 heat alarms for residential construction Alarm parts To inspect regularly when stopping the alarm sound HS-JV2 Self-checking Silence the alarm sound Flashing at alarm Send out and magnified the alarm sounds Installation notes Smoke detection part Ceiling installation. HS-JV5 T o install over 40cm of the wall from the heat detecting equipment centre (if there is the beam, it should be installed over 40cm from it.) Wall hanging T o install over 15cm of the ceiling from the heat detecting installation. equipment centre Other notes T he limited distance from the lighting fixture is 50cm. Mode HS-JV2 smoke alarms for residential construction HS-JV2 Ceiling installation. T o install in 60cm of the wall from the smoke detecting equipment centre (if there is the beam, it should be installed in about 60cm from it at least. Wall hanging T o install between 15~50cm of the ceiling from the smoke detecting installation. equipment centre Other notes If there is the air condition vent, it should be installed over 1.5 m from the smoke detecting equipment centre to the vent. T he limited distance from the lighting fixture is 50cm. Technical specification Specification Housing material Dimensions Weight. Installation type Alarm Alarm threshold value Response time Reset Time Other alarm Status Electrical Specification Supply Power voltage range The average electricity consumption Operating environment. Temperature range Humidity range Other Battery life HS-JV2 Advanced engineering plastic 100mm*41.5 mm 110g wall hanging、 ceiling HS-JV5 Advanced engineering plastic 100mm*41.5mm 100g wall hanging、 ceiling 5.0 obs% < 16 Sec. < 16 Sec. Fault indication, battery Lacking power indication 60℃ <16 Sec. < 16 Sec. Fault indication, battery indication 2.4V~3.8V <14uA 2.4V~3.8V <11uA 0~40℃ 0~95%RH,Non-condensing 0~40℃ 0~95%RH ,Non-condensing 10 years 10 years Lacking power Automatic detection Operation Normal state Detection Function Function self-test. Alarm sounder Test Automatic detection action self-test (1 time every 8 seconds) description Indicator does not light and no alarm sounds. Press the alarm buttons (for 1 sec.) Pull the draught rope (for about 1Sec.) Press the alarm buttons (for 3 seconds.) indicator LED Off Sounder Indication No Flash 1 sync Beep, normal Flash 1 sync Beep, normal Red indicator LED is on Biu,Biu,Biu,pay attention to the fire, pay attention to the fire Description indicator light Normal Off Voice prompts No Can not normally detect the smoke and sends Red LED is on out the fault alarm Beep, Beep, Beep, Pay attention to the fault Alarm and Remove the fault Detector Status The alarm takes place because of non-fire reason or can not HS-JV2 prevent the fire alarm Factor If the spray from the spray pesticides, cosmetics directly touches the smoke detecting The cigarette and other smoke fogs touch the smoke detecting equipment will cause the fault To use the sootiness, incalescence evaporative pesticides can cause the fault alarm. The cooking fog or the vapoure touches the smoke detecting equipment to cause the fault. If the smoke detecting equipment is condensed, it easily cause the fault alarm. No action Run out of battery function. at the alarm Battery connection is bad. Check Check if the pesticides, cigarette, cooking fog or the vapoure touches the smoke detecting Check if there is the dust in the smoke detecting parts Check if there is smoke fog restored in the smoke detecting parts Check if the alarm silence button can be reset or the draught rope was dragged. Treatment Exchanging the indoor air Check if the battery is lack of power. Check if the connection is in good status. Replace the battery Rightly connect it Clear dust. Disperse the smoke. Adjust the button and rope to keep normal status The alarm takes place HS-JV5 because of If roasted by the heat source, it can cause the Check if the alarm silence button can be reset Adjust the button and rope non-fire fault alarm. or the draught rope was dragged to keep normal status reason or can not prevent the fire alarm No action Run out of battery function. at the alarm Battery connection is bad. Check if the battery is lack of power. Check if the connection is in good status. Replace the battery Rightly connect it Product accessories Product Installation manual (with the Warranty Card) mm*mm installation screw mm*mm Bolt for floor slab installation installation base pothook for front installtion Special Lithium battery. Purchase Order Information M odel Decription HS-JV2 Photoelectric smoke alarms for residential fire alarm HS-JV5 Heat alarms for residential fire alarm Quantity 1 2 2 1 1 1 Installation Type wall-hanging, ceiling wall-hanging, ceiling System Sensor China 28 Tuan Jie South Road, Hi-Tech Development Zone Xi’an, 710075, China Ph:+86 29 85387800 Fx:+86 29 88325110 88332959 Web: www.systemsensor.com.cn Packing Type Separate Packing Separate Packing Unit piece piece piece piece piece piece Battery Life 10 years 10 years Repair Guarantee Period 1 year 1 year CCCF NO NO