Transcript
JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS
G1100QX
G1100X
Powered by MTU ELECTRICAL Output Rating 480v Output Rating 380v Output Rating 220v Output Rating 208v Frequency Rated Speed Power Factor ALTERNATOR Poles Winding Connections Frame Mounting Insulation Enclosure Exciter System Voltage Regulator Stead Voltage Bearing Coupling Coating
kVA kW kVA kW kVA kW kVA kW Hz RPM pf
No
Class
PRIME
STAND BY
1036 829 1000 800 1035 828 1034 827
1144 915 1050 840 1125 900 1140 912 60 1800 0.8
CIRCUIT BREAKER 1250 1600A 3200A 3200A
4 Star SAE 0-18” H IP23 Self-regulating brushless AVR (electronic) +/- 1.5% (tested G1) Single bearing sealed Flexible disc Polyester Resin
JCB Power Products LTD Rocester Staffordshire ST14 5JP, +44 (0) 1889 590312, www.jcbpowerproducts.com JCB reserves the right to change specifications without notice. Illustrations shown may include optional equipment and accessories Issue 5: G1100 60Hz 380, 480, 220V 208V MTU 08/12
ENGINE Output Rating Manufacturer Engine Model Fuel Injection Aspiration Cylinders Bore and Stroke Displacement Cooling Engine Oil Compression Ratio Fuel Consumption 100% Load Prime 75% Load Prime 50% Load Prime 100% Load Standby Lube Oil Consumption Engine Oil Capacity Coolant capacity Governor Air Filter EXHAUST SYSTEM Maximum Temperature 100% Standby Exhaust Gas Flow 100% Standby Maximum Allowed Back Pressure Exhaust Size (Internal Diameter)
kW
mm l
l/h l/h l/h l/h l l
PRIME 871
STAND BY 963 MTU 16V2000G45 Diesel Direct Turbo Charged with Inter-cooler 16V 130 x 150 31.84 Water SAE 10W40 16: 1 219.17 167.57 167.57 240.04 1% of fuel consumption 102 206 Electronic Dry
°C m³/min mbar mm
520 192 85 140
AIR SYSTEM Intake Air Flow 100% Standby Cooling Air Flow 100% Standby Alternator fan air flow
m³/h m³/h m³/s
4,860 88,560 1.961
STARTING SYSTEM Starter Motor Battery Capacity Auxiliary Voltage Starter Current – Maximum Power – Firing Speed
kW Ah V Amp Amp
9.5 260 24 1600 800
bar bar l l
Diesel +0.5 -0.3 940 999
FUEL SYSTEM Fuel Maximum Fuel Pressure at Connection Minimum Fuel Pressure at Connection Open Skid Fuel Tank Capacity Container Fuel Tank Capacity
JCB Power Products LTD Rocester Staffordshire ST14 5JP, +44 (0) 1889 590312, www.jcbpowerproducts.com JCB reserves the right to change specifications without notice. Illustrations shown may include optional equipment and accessories Issue 5: G1100 60Hz 380, 480, 220V 208V MTU 08/12
WEIGHT AND DIMENSIONS - OPEN Length Width Height Shipping Volume (Sea Ready) Weight (Standard Build inclusive of oil and coolant)
mm mm mm m³ Kg
4,950 1,836 2,447 22.24 6,840
JCB G1100X
WEIGHT AND DIMENSIONS - 20 ISO CONTAINER Length mm Width mm Height mm Shipping Volume (Sea Ready) m³ Wet Weight (Standard Build) Kg Dry Weight (Standard Build) Kg Sound Level @ 1M db(A)
6,096 2,438 2,591 33.1 12,340 12,100 80
JCB G1100QX
JCB Power Products LTD Rocester Staffordshire ST14 5JP, +44 (0) 1889 590312, www.jcbpowerproducts.com JCB reserves the right to change specifications without notice. Illustrations shown may include optional equipment and accessories Issue 5: G1100 60Hz 380, 480, 220V 208V MTU 08/12
CONTROL PANEL – JCB CP1 The JCB CP1 control system is digital and has the capability to control, monitor and protect the generator. The display allows the user to easily monitor the status of the generator through an LCD display and LED outputs. It enables control of the generator operations through soft touch push button functionality and multi lingual capability
CONTROL PANEL – JCB CP2 The JCB CP2 control system is digital and has the capability to control, monitor and protect the generator the same as the JCB CP1 panel but additionally incorporates the functionality of the control module of the JCB ATP1. The JCB CP2 Panel constantly monitors the mains and has to be hardwired into both mains and generator contactors. The display allows the user to easily monitor the status of the generator as well as controlling generator operation
CONTROL PANEL – JCB ATP1 The JCB ATP1 control module is integrated into an Automatic Transfer Switch, which provides automatic mains failure capability. The JCB ATP1 can communicate with a generator through either 2 wire start volt free contactors or CANBUS through CP1 to ATP1 (not compatible with CP2). The JCB ATP1 when connected via CANBUS to the JCB CP1 will give control functions and display generator information.
JCB Power Products LTD Rocester Staffordshire ST14 5JP, +44 (0) 1889 590312, www.jcbpowerproducts.com JCB reserves the right to change specifications without notice. Illustrations shown may include optional equipment and accessories Issue 5: G1100 60Hz 380, 480, 220V 208V MTU 08/12
CONTROL PANEL FEATURES GENERATOR Phase to Phase Voltage Phase to Neutral Phase Amperage Frequency kVA Kw kVAr Power Factor MAINS Phase to Phase Voltage Phase to Neutral Phase Amperage Frequency kVA Kw kVAr Power Factor ENGINE Coolant Temperature Oil Pressure Fuel Level Percentage Battery Voltage Engine RPM Battery Charge Alternator Voltage ENGINE ALARMS High Water temperature High Coolant Temperature Low Oil Pressure Low Coolant Level Unexpected Shutdown Failure to Stop Battery Voltage Failure Battery Charge Alternator Failure Over Speed Under Speed Failure to Start Low Fuel level Emergency Stop ALTERNATOR ALARMS High Frequency Low Frequency High Voltage Low Voltage Over Amperage Short Circuit Symmetry Between Phases Incorrect Phasing Inverse Power Over Load Generator Drop
CP1
CP2
ATP1
x x x x x x x x
x x x x
x x x x x x
x x x x x x x x x x x x
x
x
x x x x
Standard
x Not Available
JCB Power Products LTD Rocester Staffordshire ST14 5JP, +44 (0) 1889 590312, www.jcbpowerproducts.com JCB reserves the right to change specifications without notice. Illustrations shown may include optional equipment and accessories Issue 5: G1100 60Hz 380, 480, 220V 208V MTU 08/12
CONTROL PANEL FEATURES MEASUREMENT Total Hours Run Kilowatt Meter Number of Starts Number of Start Failures Service Indicator CONNECTIVITY Remote Screen (CAN) Local Monitoring (CANBUS) Local Monitoring (CANLAN) Remote Monitoring (CANModem – Fixed) Remote Monitoring (CANModem – GSM) FEATURES Events History External Start capability Programmable Start Restriction Mains Failure Start Generator Contact Activation Mains and Generators Contact Activation Fuel Transfer Control Engine Temperature Manual Override Programmable Alarms Generator Start in Test Mode Programmable Outputs Multi Lingual Programmable Timer Synchronisation
CP1
CP2
ATP1
x
x
Standard
x x x x x x x x x x Not Available Optional
REFERENCE STANDARDS JCB Generators are CE certified and conform to the following Directives (subject to a country requiring such standard):
EN 12100, EN13857, EN60204 2006/42/CE Machinery safety 2006/95/EC Low voltage 2004/108/CE Electromagnetic compatibility 2000/14/EC Sound Power Level (amended by 2005/88/EC) 97/68/EC Emissions(amended by 2002/88/EC & 2004/26/EC) Ambient reference conditions 1000mbar, 25°C, 30% relative humidity ISO3046 Power according to ISO 8528 and ISO 3046 Information based on standard specification equipment unless otherwise stated.
Prime: This rating is for the supply of continuous electrical power, at variable load, in lieu of commercially purchase power. There is no limitation on the annual hours of operation and 10% over load power can be supplied for 1 hour in 12. Standby: This rating is for the supply of continuous electrical power, at variable load, in the event of a Utility power failure. No overload is permitted. JCB Power Products LTD Rocester Staffordshire ST14 5JP, +44 (0) 1889 590312, www.jcbpowerproducts.com JCB reserves the right to change specifications without notice. Illustrations shown may include optional equipment and accessories Issue 5: G1100 60Hz 380, 480, 220V 208V MTU 08/12
GENERATOR FEATURES ENGINE Engine Cooling Pack Tropicalised Radiator Heavy Duty Air Filter MTU ADEC Governor High Water Temperature Sender Low Oil Pressure Sender Oil Temperature Sender Radiator Guards Hot Component Guards Manual Oil Drain Pump Electric Oil Drain Pump Fuel Heater Electric Fuel Transfer Pump Low Coolant Level Senders Battery Charger Water Jacket Heater Exhaust Gas Compensator Industrial Silencer – Open Set Residential Silencer – Open Set Residential Silencer – Container ELECTRICS Alternator Circuit Breaker Busbar Heavy Duty Batteries Battery Isolator Preparation for Earth Spike Anti-condensation Heater Optional Voltages Class F Insulation JCB CP1 Digital Controller JCB CP2 Digital Controller JCB ATP1 Automatic Transfer Switch CONTAINER External Emergency Stop Button Heavy Duty Base Frame Integral Fuel Tank Rockwool Sound Attenuation Window for External Control Panel View Anti-condensation Heater
STANDARD
OPTIONAL
x x x x x x x
x x x x x x x x x x x x x x
x x x x x
x x x x x x x
x
x x x x x
JCB Power Products LTD Rocester Staffordshire ST14 5JP, +44 (0) 1889 590312, www.jcbpowerproducts.com JCB reserves the right to change specifications without notice. Illustrations shown may include optional equipment and accessories Issue 5: G1100 60Hz 380, 480, 220V 208V MTU 08/12