Preview only show first 10 pages with watermark. For full document please download

контроллер Jh-dmx-ir18b (12/24v, 240/480w, пду)

   EMBED


Share

Transcript

Контроллер JH-DMX-IR18B (12/24V, 240/480W, ПДУ) Features: • With high-speed MCU and N-MOS to get excellent & reliable controlling effect. • Drive by DMX512 1990 and DMX512A console, manual code editor with 10-bit binary address code • Can be connected with suitable amplifier to expand the extension. • With 49 kind of color changing mode, you can choose the mode by 18 key remote transmitter. • Different color change mode in different color key, can be choosed easily. • IR remote distance: 6 meter. • 6553 level grey, can show 6553x6553x6553 kinds of color. • Input Volt: DC12V~DC24V. • Output: 5A/channel, total 4 channel. • Common anode design. • Maximum loading: DC12V---240W or DC24V---480W • Controller power consumption≤1W. • Controller temperature rise itself: <50 degree. • Memory storage >40 years. • Interference pulse voltage ≥5000V • Applicable to all linear constant current led lighting or other current limited by resistor led products. • IP20 for indoor use only. Size: 123mmx45mmx29mm • Working temperature: -20oC~45oC Products pictures: Function Description: 1. DMX512 use 10-bit dial switch to setup the code, when the code is “0”, it is for IR remote program mode. All the other code is for DMX mode. 2. If the exchanged number is not full 10-bit number, fill “0” to make the number be 10-bit. For example: Code “127”, exchange to binary code is “ 111 111 1”, fill “0” to be “111 111 1000”. 3. Match with the 1st to 10th Switch to set the code dial switch down for “0”, dial switch up for “1” 4. The DMX640A is 4 channel controller, means one DMX640A hold 4 ID code. For example: The 1st controller ID code is “ 100 000 0000”, the 2nd controller ID code is “101 000 0000”. 5. The black color is address switch in the below diagram. IR Remote Setup: 1. When the DMX code dial switch to be “0”, it is IR program function. 2. MODE: with 49 kinds of color change program for option. SPEED: There are 1-10 level speed for option. BRIGHT: There are 0-10 level brightness for option. Color Key: Each color change program is holded in each color key, can choose this color program directly from the color key. AUTO: All the mode changing automaticaly in turn. PAUSE: Can stop the color changing program. If continue the same mode, press PAUSE key or enter into other change mode pressing other key directly. RESET: When press RESET key 5-15 second, the controller come back to initial mode, and the speed and brightness will be back to initial mode. ON/OFF: When you press the OFF, the program is off, but the controller is still working. 3. DIY color: when the controller is in the gradual change mode, when you found your favorite color, then press the PAUSE key to pause, and then press RESET button (in 1 second), this color can be stored as the 1st changing mode. Then press PAUSE again to make the program continue. You can find this color by MODE key. When you reset another new color as saved, the former saved color will be offseted. IR Remote Transmitter: Color Key Program: 1st Press 2nd Press 3rd Press 4th Press 5th Press 6th Press 7th Press Red color light Red & White color light together Gradual change: Red - White Flash change: Red - White Red color dimmer and brighter Red color flash Red & White dimmer and brighter Green color light Ged & White color light together Gradual change: Green - White Flash change: Green - White Green color dimmer and brighter Green color flash Green & White dimmer and brighter Blue color light Blue & White color light together Gradual change: Blue - White Flash change: Blue - White Blue color dimmer and brighter Blue color flash Blue & White dimmer and brighter Yellow & White color light together Gradual change: Yellow - White Flash change: Yellow - white Yellow color dimmer and brighter Yellow color flash Gradual change Red-Green Cyan & White color light together Gradual change: Cyan - White Flash change: Cyan - white Cyan color dimmer and brighter Cyan color flash Gradual change Green-Blue Purple & White color light together Gradual change: Purple - White flash change: Purple - White Purple color dimmer and brighter Purple color flash Gradual change Red-Blue White color dimmer and brighter Gradual change: Red-WhiteGreen-WhiteBlue-WhiteYellow-WhiteCyan-White- Gradual change: Red-GreenBlue-YellowCyan-PurpleWhite Flash change: Red-GreenBlue-YellowCyan-PurpleWhite Flash change: Red-GreenBlue Yellow color light Cyan color light Purple color light RGB color light together RGB & White color light together * The programme of the controller will be increased without notice from time to time based on the actual development needs, programme to match the actual specification of the goods subject to the actual. ATTENTION: • IR remote function, only single color or color flash, brightness can be changed. • When pressing the button, always direct the remote control towards the sensor IR and the middle interval of more than 2 seconds. There must be no obstacles between the remote control and the sensor. • Please remove the insulation sheet from the battery cabin before using. • If the range of the remote control decreases, replace the battery, if the remote control is not used for a longer period, remove the battery. • When pressing the button “off”, the lamp is still working, the power consumption is about 0.1W totally. Connection Diagram: ( 1 ) With DMX Control Desk: The controller quantity to load is limited by DMX Control Desk. For example, if the DMX control Desk is 192 channel, so it can load 64pcs controllers maximum. ( 2 ) Single One controller: ( 3 ) Controller with amplifier connection: ( 4 ) Connection for beyond the control input voltage: NOTE: The controller can drive the RGB products from DC5V to DC36V, can not lower than DC5V, can not over DC36V. Simple Troubleshooting Guide: Problem Check place 1 Color change is irregular flash Check the singnal cable, maybe the cable is brocken inside. 2 Only RED color light, the blue and green color no light or a little light Check the input voltage, maybe the input volt is lower than required 3 No output, the work light do not light. Check the power input cable, maybe the Positive and negative is revised. 4 DMX control desk ID code is not matched with controller. Check if the ID code of the controller is wrong, please calculate and setup the ID again. 5 Only can run in dimmer and brighter program, no other program output. Set up the brightness to the highest brightness Application: ATTENTION: • Indoor Use ONLY, Protect it against dripping water and splash water, high air humidity and heat (admissible ambient temperature range 0-40oC.) • For cleaning only use a dry, soft cloth; never use chemicals or water. • No guarantee claims for the unit and no liability for any resulting personal damage or material damage will be accepted if the unit is used for other purposes than originally intended, if it is not correctly connected or operated, if it is over-loaded or not repaired in an expert way. • When over-load, the controller will stop working, then please reduce the loading into the right way, then the controller can start again. WARNING: • Please check before installation that the LED light input voltage fits to the voltage showed on the lamp and controllers. • Please do not overload. • Make sure the power off when you install the controller. • Do not store this product in places with high temperature or high humidity. • Controller does not lightning, please use it with Lightning Protection Devices