Transcript
VDE
To Be Discontinued Last time buy: September 30, 2016
Ideal for compressor and motor control Inrush 80A, 1a 20A power relay
JM RELAYS
FEATURES • Compact, high-capacity, and resistant to inductive loads It can control an inductive load with inrush current of 80 A and steady state current of 20 A. • Excellent contact welding resistance High contact pressure, a forced opening mechanism, and a forced wiping mechanism realizes an excellent contact welding resistance. • High breakdown voltage and surge resistant relay More than 6.4 mm .252 inch maintained for the insulation distance between contacts and coil, and the breakdown voltage between contacts and coil is 5,000 V for 1 minute. In addition, the surge resistance between contacts and coil is greater than 10,000 V. • Resistant to external force An absorber mechanism is used on the load terminals, giving a large improvement in characteristics variations caused by the external force during FASTON placement/removal. • Flux resistance mechanism The terminal area is plugged with resin to prevent flux seepage during PCB mounting. (TMP type)
Flat type
Slim type
RoHS compliant
• Conforms to the various safety standards UL, CSA, VDE available • The line up can support economical mounting methods. The relay are equipped with a drive terminal (coil terminal) on one side for PCBs, and a load terminal (tab terminal #250) on the reverse side. The line up includes the TM type which can be attached directly to the PCB composing a drive circuit, and the TMP type which supports economical wiring. The TMP type can also be directly attached, and a high capacity load can be wired to the tab terminal.
TYPICAL APPLICATIONS • Compressor and heater control in air conditioners • Power control in hot air type heaters • Magnetron control in microwave ovens • Lamp and motor control in OA equipment such as copiers and facsimiles.
ORDERING INFORMATION JM
1a
N
F
JM relay Contact arrangement 1a: 1 Form A Pickup voltage N: 70% of nominal voltage Classification of type Nil: Slim type Z: Flat type Mounting classification TMP: TMP type TM: TM type (Flat type) P: PCB type (Slim type) Nominal coil voltage DC5V, DC6V, DC9V, DC12V, DC24V, DC48V Contact material F: AgSnO2 type Note: Certified by UL, CSA and VDE
–1–
ASCTB184E 201509-T
To Be Discontinued Last time buy: September 30, 2016
JM TYPES Nominal coil voltage 5V DC 6V DC 9V DC 12V DC 24V DC 48V DC
Part No. TMP type (Flat) JM1aN-ZTMP-DC5V-F JM1aN-ZTMP-DC6V-F JM1aN-ZTMP-DC9V-F JM1aN-ZTMP-DC12V-F JM1aN-ZTMP-DC24V-F JM1aN-ZTMP-DC48V-F
TM type (Flat) JM1aN-ZTM-DC5V-F JM1aN-ZTM-DC6V-F JM1aN-ZTM-DC9V-F JM1aN-ZTM-DC12V-F JM1aN-ZTM-DC24V-F JM1aN-ZTM-DC48V-F
TMP type (Slim) JM1aN-TMP-DC5V-F JM1aN-TMP-DC6V-F JM1aN-TMP-DC9V-F JM1aN-TMP-DC12V-F JM1aN-TMP-DC24V-F JM1aN-TMP-DC48V-F
PCB type (Slim) JM1aN-P-DC5V-F JM1aN-P-DC6V-F JM1aN-P-DC9V-F JM1aN-P-DC12V-F JM1aN-P-DC24V-F JM1aN-P-DC48V-F
Standard packing: Carton 50 pcs., Case 200 pcs.
RATING 1. Coil data Nominal coil voltage
Pick-up voltage (at 20°C 68°F)
Drop-out voltage (at 20°C 68°F)
5V DC
Nominal operating current [±10%] (at 20°C 68°F) 180
6V DC 9V DC 12V DC 24V DC 48V DC
70%V or less of nominal voltage (Initial)
10%V or more of nominal voltage (Initial)
mA
Coil resistance [±10%] (at 20°C 68°F)
Nominal operating power
Max. applied voltage (at 60°C 140°F)
900mW
110%V of nominal voltage
27.8Ω
150 mA 100 mA 75 mA 37.5 mA 18.75mA
40 90 160 640 2,560
Ω Ω Ω Ω Ω
2. Specifications Characteristics Contact
Rating
Item AgSnO2 type
Arrangement Contact resistance (Initial) Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Min. switching capacity (reference value)*1 Insulation resistance (Initial)
1 Form A Max. 100 mΩ (By voltage drop 6 V DC 1A) 20A 250V AC 5,000VA 250V AC 20A 100mA, 5V DC Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Between open contacts Between contact and coil
Breakdown voltage (Initial) Electrical characteristics
Temperature rise (coil) Surge breakdown voltage*2 (Between contact and coil) (Initial) Operate time (at nominal voltage) (at 20°C 68°F) Release time (at nominal voltage) (at 20°C 68°F) Functional Destructive Functional Vibration resistance Destructive Mechanical (at 180 times/min.) Electrical (at 20 times/min.) Shock resistance
Mechanical characteristics
Expected life
Conditions
Specifications
Contact material
Conditions for operation, transport and storage*3 Max. operating speed
Unit weight
1,000 Vrms for 1 min. (Detection current: 10 mA) 5,000 Vrms for 1 min. (Detection current: 10 mA) Max. 55°C 131°F (By resistive method, nominal coil voltage applied to coil: 100%V, contact carrying current: 20A, at 60°C 140°F) 10,000 V Max. 20 ms (excluding contact bounce time.) Max. 10 ms (excluding contact bounce time) (Without diode) 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.) 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 2 mm Min. 106 Min. 105 (at nominal switching capacity) Ambient temperature: –40°C to +60°C –40°F to +140°F, Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at nominal switching capacity) Slim TMP and Slim PCB: Approx. 28 g .99 oz Flat TMP: Approx. 30 g 1.06 oz Flat TM: Approx. 30 g 1.06 oz
* Specifications will vary with foreign standards certification ratings. Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES.
3. Switching capacity Resistive load Electrical Life Inductive load (cosφ = 0.7)
20 A, 250 V AC (cosφ = 1) Inrush 70 A, Steady 20 A (250 V AC cosφ = 0.7) Inrush 80 A, Cut-off 80 A (When the motor is locked) (250 V AC cosφ = 0.7)
105 (at 20 times/min.) 105 (at 20 times/min.) 1.5×103 (at 20 times/min.)
Note: Standard UL and CSA 1HP, 20A 250VAC 11/2HP, 20A 125VAC
–2–
ASCTB184E 201509-T
To Be Discontinued Last time buy: September 30, 2016
JM
REFERENCE DATA 1. Coil temperature rise
2. Life curve
3. Operate/release time
Place to be measured: Inside of coil Ambient temperature: 25°C 77°F
Sample: JM1aN-TMP-DC24V-F, 5 pcs.
60
20A Operate/release time, ms
0A
50 Life, ×104
Temperature rise, °C
100 50
40
30
250V AC resistive load 10
20
0
80
90
100 110 120
130
5
10
15
20
14 13 12 11 10 9 8 7 6 5 4 3 2 0
Operate time
Max. xMin. Release time
80
90
Contact current, A
Coil applied Voltage, %V
Max. xMin.
100 110 120 130 Coil applied voltage, %V
4. Ambient temperature characteristics
Change, %
Sample: JM1aN-TMP-DC24V-F, 5 pcs. 30 Drop-out voltage 20 10 Pick-up voltage –40 –20
0
20 40 60 80 Ambient temperature, °C –10 –20 –30
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
Flat TMP type Schematic
a. di . 0 ia 2. 9 d 7 .0
31 1.220
PC board pattern (Bottom view)
N.O.
2.15 .085
COM
20±0.1 .787±.004
N.O.
COM
8 15 .315 .591
Faston 250
6.35 .250
9.9 .390 18 .709
1.5 .059
2.15 .085 0.8 .031
6.8 .268
Faston 250
COM
N.O.
24.5±0.1 .965±.004
Coil PC board side 0.2 .008
N.O.
1 .0 .8 d 71 ia. dia .
COM
28.5 1.122
2 .0 .0 d 79 ia di . a.
External dimensions
CAD Data
2.5±0.1 .098±.004
Coil
5.2 .205
22±0.1 .866±.004
1 .0 .8 d 71 ia dia . .
Tolerance: ±0.1 ±.004
17.2 .677
1 .039 4.5 .177
3.5 .138 6.2 .224 17 .669
24 .945
5 COM
1
6 N.O. 2
9.2 .362
General tolerance: ±0.4 ±.016
–3–
ASCTB184E 201509-T
To Be Discontinued Last time buy: September 30, 2016
JM Flat TM type External dimensions
CAD Data
11.2 .441
28.5 1.122 4.5 .177
47.5 1.870 31 1.220
Schematic
Panel cutout 39.5±0.1 1.555±.004
Faston 187 10 .394
Coil
2-4.5±0.1 dia. 2-.177±.004 dia. N.O.
COM
R2.25 R.088
N.O.
Faston 250
COM
39.5 1.555 8 15 .315 .591 9.9 .390 17.6 2 .693 .079
6.35 .250
2.15 .085 0.8 .031
1.5 .059
6.8 .268
Faston 250
Faston 187 1.85 .073
0.5 .020 8.2 .323 16.8 .661
0.6 .024
General tolerance: ±0.4 ±.016
Slim TMP type External dimensions
CAD Data 12.9 .508
Schematic FASTON 250
6.35 .250
11 .433
PC board pattern (Copper-side view)
10.0 .394
N.O.
26.0 1.024 0.5 .020 12.0 10.0 .472 .394 27.6 30.4 1.087 1.197 3 N.O. 1
4 COM
2 26.0 1.024
1.8 .071
COM
PC board side
12.0 .472 16.0 .630
4.0 .157
27.6±0.1 .0 2. 1.087±.004 79 0± ±. 0. 13.8±0.1 00 1 4 dia .543±.004 di . a.
a. a. di di 1 04 . 0 0 0± ±. 2. 79 .0
12.0±0.1 .472±.004 1 . .07 .8±0 dia . .1 ia 1 . ±0 04 d12.0±0.1 10.0±0.1 ±.0 1 dia 8 . 1 ±.0 .472±.004 .394±.004 04 . dia 1 7 . .0
Tolerance: ±0.1 ±.004
6.0 .236
General tolerance: ±0.4 ±.016
Slim PCB type External dimensions
CAD Data
Schematic N.O. 26.0 1.024 0.5 .020
12.0 10.0 .472 .394 27.6 30.4 1.087 1.197 3 N.O. 1
4 COM
2 26.0 1.024
1.8 .071
12.0 .472 16.0 .630
PC board pattern (Copper-side view) COM
PC board side
27.6±0.1 .0 2. 1.087±.004 79 0± ±. 0. 13.8±0.1 00 1 4 dia .543±.004 di . a.
a. a. di di 1 04 . 0 0 0± ±. 2. 79 .0
12.0±0.1 .472±.004 1 . .07 .8±0 dia . .1 ia 1 . ±0 04 d12.0±0.1 10.0±0.1 ±.0 1 dia 8 . 1 ±.0 .472±.004 .394±.004 04 . dia 1 7 . .0
4.0 .157
Tolerance: ±0.1 ±.004
6.0 .236
General tolerance: ±0.4 ±.016
SAFETY STANDARDS Item
File No. E43028
Slim type E43028 Flat type
UL/C-UL (Recognized) Contact rating 20A 125V AC 20A 250V AC 11/2HP 125V AC 1HP 250V AC 20A 125V AC 20A 250V AC 11/2HP 125V AC 1HP 250V AC
File No. LR26550
LR26550
CSA (Certified) Contact rating 20A 125V AC 20A 250V AC 11/2HP 125V AC 1HP 250V AC 20A 125V AC 20A 250V AC 11/2HP 125V AC 1HP 250V AC
File No. 40014275
40014275
VDE (Certified) Contact rating 20A 250V AC (cosφ =1.0) 12A 220V AC (cosφ =0.4) 20A 250V AC (cosφ =1.0) 12A 230V AC (cosφ =0.4)
For Cautions for Use.
–4–
ASCTB184E 201509-T