Preview only show first 10 pages with watermark. For full document please download

Jm Relays Features Ideal For Compressor And Motor Control

   EMBED


Share

Transcript

VDE To Be Discontinued Last time buy: September 30, 2016 Ideal for compressor and motor control Inrush 80A, 1a 20A power relay JM RELAYS FEATURES • Compact, high-capacity, and resistant to inductive loads It can control an inductive load with inrush current of 80 A and steady state current of 20 A. • Excellent contact welding resistance High contact pressure, a forced opening mechanism, and a forced wiping mechanism realizes an excellent contact welding resistance. • High breakdown voltage and surge resistant relay More than 6.4 mm .252 inch maintained for the insulation distance between contacts and coil, and the breakdown voltage between contacts and coil is 5,000 V for 1 minute. In addition, the surge resistance between contacts and coil is greater than 10,000 V. • Resistant to external force An absorber mechanism is used on the load terminals, giving a large improvement in characteristics variations caused by the external force during FASTON placement/removal. • Flux resistance mechanism The terminal area is plugged with resin to prevent flux seepage during PCB mounting. (TMP type) Flat type Slim type RoHS compliant • Conforms to the various safety standards UL, CSA, VDE available • The line up can support economical mounting methods. The relay are equipped with a drive terminal (coil terminal) on one side for PCBs, and a load terminal (tab terminal #250) on the reverse side. The line up includes the TM type which can be attached directly to the PCB composing a drive circuit, and the TMP type which supports economical wiring. The TMP type can also be directly attached, and a high capacity load can be wired to the tab terminal. TYPICAL APPLICATIONS • Compressor and heater control in air conditioners • Power control in hot air type heaters • Magnetron control in microwave ovens • Lamp and motor control in OA equipment such as copiers and facsimiles. ORDERING INFORMATION JM 1a N F JM relay Contact arrangement 1a: 1 Form A Pickup voltage N: 70% of nominal voltage Classification of type Nil: Slim type Z: Flat type Mounting classification TMP: TMP type TM: TM type (Flat type) P: PCB type (Slim type) Nominal coil voltage DC5V, DC6V, DC9V, DC12V, DC24V, DC48V Contact material F: AgSnO2 type Note: Certified by UL, CSA and VDE –1– ASCTB184E 201509-T To Be Discontinued Last time buy: September 30, 2016 JM TYPES Nominal coil voltage 5V DC 6V DC 9V DC 12V DC 24V DC 48V DC Part No. TMP type (Flat) JM1aN-ZTMP-DC5V-F JM1aN-ZTMP-DC6V-F JM1aN-ZTMP-DC9V-F JM1aN-ZTMP-DC12V-F JM1aN-ZTMP-DC24V-F JM1aN-ZTMP-DC48V-F TM type (Flat) JM1aN-ZTM-DC5V-F JM1aN-ZTM-DC6V-F JM1aN-ZTM-DC9V-F JM1aN-ZTM-DC12V-F JM1aN-ZTM-DC24V-F JM1aN-ZTM-DC48V-F TMP type (Slim) JM1aN-TMP-DC5V-F JM1aN-TMP-DC6V-F JM1aN-TMP-DC9V-F JM1aN-TMP-DC12V-F JM1aN-TMP-DC24V-F JM1aN-TMP-DC48V-F PCB type (Slim) JM1aN-P-DC5V-F JM1aN-P-DC6V-F JM1aN-P-DC9V-F JM1aN-P-DC12V-F JM1aN-P-DC24V-F JM1aN-P-DC48V-F Standard packing: Carton 50 pcs., Case 200 pcs. RATING 1. Coil data Nominal coil voltage Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) 5V DC Nominal operating current [±10%] (at 20°C 68°F) 180 6V DC 9V DC 12V DC 24V DC 48V DC 70%V or less of nominal voltage (Initial) 10%V or more of nominal voltage (Initial) mA Coil resistance [±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 60°C 140°F) 900mW 110%V of nominal voltage 27.8Ω 150 mA 100 mA 75 mA 37.5 mA 18.75mA 40 90 160 640 2,560 Ω Ω Ω Ω Ω 2. Specifications Characteristics Contact Rating Item AgSnO2 type Arrangement Contact resistance (Initial) Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Min. switching capacity (reference value)*1 Insulation resistance (Initial) 1 Form A Max. 100 mΩ (By voltage drop 6 V DC 1A) 20A 250V AC 5,000VA 250V AC 20A 100mA, 5V DC Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section. Between open contacts Between contact and coil Breakdown voltage (Initial) Electrical characteristics Temperature rise (coil) Surge breakdown voltage*2 (Between contact and coil) (Initial) Operate time (at nominal voltage) (at 20°C 68°F) Release time (at nominal voltage) (at 20°C 68°F) Functional Destructive Functional Vibration resistance Destructive Mechanical (at 180 times/min.) Electrical (at 20 times/min.) Shock resistance Mechanical characteristics Expected life Conditions Specifications Contact material Conditions for operation, transport and storage*3 Max. operating speed Unit weight 1,000 Vrms for 1 min. (Detection current: 10 mA) 5,000 Vrms for 1 min. (Detection current: 10 mA) Max. 55°C 131°F (By resistive method, nominal coil voltage applied to coil: 100%V, contact carrying current: 20A, at 60°C 140°F) 10,000 V Max. 20 ms (excluding contact bounce time.) Max. 10 ms (excluding contact bounce time) (Without diode) 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.) 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 2 mm Min. 106 Min. 105 (at nominal switching capacity) Ambient temperature: –40°C to +60°C –40°F to +140°F, Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at nominal switching capacity) Slim TMP and Slim PCB: Approx. 28 g .99 oz Flat TMP: Approx. 30 g 1.06 oz Flat TM: Approx. 30 g 1.06 oz * Specifications will vary with foreign standards certification ratings. Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. 3. Switching capacity Resistive load Electrical Life Inductive load (cosφ = 0.7) 20 A, 250 V AC (cosφ = 1) Inrush 70 A, Steady 20 A (250 V AC cosφ = 0.7) Inrush 80 A, Cut-off 80 A (When the motor is locked) (250 V AC cosφ = 0.7) 105 (at 20 times/min.) 105 (at 20 times/min.) 1.5×103 (at 20 times/min.) Note: Standard UL and CSA 1HP, 20A 250VAC 11/2HP, 20A 125VAC –2– ASCTB184E 201509-T To Be Discontinued Last time buy: September 30, 2016 JM REFERENCE DATA 1. Coil temperature rise 2. Life curve 3. Operate/release time Place to be measured: Inside of coil Ambient temperature: 25°C 77°F Sample: JM1aN-TMP-DC24V-F, 5 pcs. 60 20A Operate/release time, ms 0A 50 Life, ×104 Temperature rise, °C 100 50 40 30 250V AC resistive load 10 20 0 80 90 100 110 120 130 5 10 15 20 14 13 12 11 10 9 8 7 6 5 4 3 2 0 Operate time Max. xMin. Release time 80 90 Contact current, A Coil applied Voltage, %V Max. xMin. 100 110 120 130 Coil applied voltage, %V 4. Ambient temperature characteristics Change, % Sample: JM1aN-TMP-DC24V-F, 5 pcs. 30 Drop-out voltage 20 10 Pick-up voltage –40 –20 0 20 40 60 80 Ambient temperature, °C –10 –20 –30 DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ Flat TMP type Schematic a. di . 0 ia 2. 9 d 7 .0 31 1.220 PC board pattern (Bottom view) N.O. 2.15 .085 COM 20±0.1 .787±.004 N.O. COM 8 15 .315 .591 Faston 250 6.35 .250 9.9 .390 18 .709 1.5 .059 2.15 .085 0.8 .031 6.8 .268 Faston 250 COM N.O. 24.5±0.1 .965±.004 Coil PC board side 0.2 .008 N.O. 1 .0 .8 d 71 ia. dia . COM 28.5 1.122 2 .0 .0 d 79 ia di . a. External dimensions CAD Data 2.5±0.1 .098±.004 Coil 5.2 .205 22±0.1 .866±.004 1 .0 .8 d 71 ia dia . . Tolerance: ±0.1 ±.004 17.2 .677 1 .039 4.5 .177 3.5 .138 6.2 .224 17 .669 24 .945 5 COM 1 6 N.O. 2 9.2 .362 General tolerance: ±0.4 ±.016 –3– ASCTB184E 201509-T To Be Discontinued Last time buy: September 30, 2016 JM Flat TM type External dimensions CAD Data 11.2 .441 28.5 1.122 4.5 .177 47.5 1.870 31 1.220 Schematic Panel cutout 39.5±0.1 1.555±.004 Faston 187 10 .394 Coil 2-4.5±0.1 dia. 2-.177±.004 dia. N.O. COM R2.25 R.088 N.O. Faston 250 COM 39.5 1.555 8 15 .315 .591 9.9 .390 17.6 2 .693 .079 6.35 .250 2.15 .085 0.8 .031 1.5 .059 6.8 .268 Faston 250 Faston 187 1.85 .073 0.5 .020 8.2 .323 16.8 .661 0.6 .024 General tolerance: ±0.4 ±.016 Slim TMP type External dimensions CAD Data 12.9 .508 Schematic FASTON 250 6.35 .250 11 .433 PC board pattern (Copper-side view) 10.0 .394 N.O. 26.0 1.024 0.5 .020 12.0 10.0 .472 .394 27.6 30.4 1.087 1.197 3 N.O. 1 4 COM 2 26.0 1.024 1.8 .071 COM PC board side 12.0 .472 16.0 .630 4.0 .157 27.6±0.1 .0 2. 1.087±.004 79 0± ±. 0. 13.8±0.1 00 1 4 dia .543±.004 di . a. a. a. di di 1 04 . 0 0 0± ±. 2. 79 .0 12.0±0.1 .472±.004 1 . .07 .8±0 dia . .1 ia 1 . ±0 04 d12.0±0.1 10.0±0.1 ±.0 1 dia 8 . 1 ±.0 .472±.004 .394±.004 04 . dia 1 7 . .0 Tolerance: ±0.1 ±.004 6.0 .236 General tolerance: ±0.4 ±.016 Slim PCB type External dimensions CAD Data Schematic N.O. 26.0 1.024 0.5 .020 12.0 10.0 .472 .394 27.6 30.4 1.087 1.197 3 N.O. 1 4 COM 2 26.0 1.024 1.8 .071 12.0 .472 16.0 .630 PC board pattern (Copper-side view) COM PC board side 27.6±0.1 .0 2. 1.087±.004 79 0± ±. 0. 13.8±0.1 00 1 4 dia .543±.004 di . a. a. a. di di 1 04 . 0 0 0± ±. 2. 79 .0 12.0±0.1 .472±.004 1 . .07 .8±0 dia . .1 ia 1 . ±0 04 d12.0±0.1 10.0±0.1 ±.0 1 dia 8 . 1 ±.0 .472±.004 .394±.004 04 . dia 1 7 . .0 4.0 .157 Tolerance: ±0.1 ±.004 6.0 .236 General tolerance: ±0.4 ±.016 SAFETY STANDARDS Item File No. E43028 Slim type E43028 Flat type UL/C-UL (Recognized) Contact rating 20A 125V AC 20A 250V AC 11/2HP 125V AC 1HP 250V AC 20A 125V AC 20A 250V AC 11/2HP 125V AC 1HP 250V AC File No. LR26550 LR26550 CSA (Certified) Contact rating 20A 125V AC 20A 250V AC 11/2HP 125V AC 1HP 250V AC 20A 125V AC 20A 250V AC 11/2HP 125V AC 1HP 250V AC File No. 40014275 40014275 VDE (Certified) Contact rating 20A 250V AC (cosφ =1.0) 12A 220V AC (cosφ =0.4) 20A 250V AC (cosφ =1.0) 12A 230V AC (cosφ =0.4) For Cautions for Use. –4– ASCTB184E 201509-T