SUBMITTAL AQN18VFUAGM / AQX18VFUAGM
www.Quietside.com
AQN18VFUAGM Max, wall mounted evaporator, single zone split system
Job Name Purchaser Submitted to Unit Designation
Location Engineer Reference Schedule #
Approval
Construction
Specifications Nominal Capacity
Performance
Cooling (Btu/h) Heating (Btu/h) Cooling (Btu/h) Capacity Range Heating (Btu/h) SEER / EER HSPF Condensate (pints/hour)
Power
Voltage (ø/V/Hz) Working Voltage Range (VAC) Rated Current Cooling (A) (Low/Std./Max.) Heating (A) Max. Breaker (A) Min. Circuit Ampacity (A) WXHXD (inches)
Indoor Unit Outdoor Unit Indoor Unit Weight (lbs.) Outdoor Unit Condensate Connection
Dimensions
Indoor & Outdoor Unit
Heat Exchanger
Type FPI Pipe Diameter
Indoor Unit Outdoor Unit Sound Pressure Level (dB) Operating Temperatures (ͼF)
Pipe Connections
Refrigerant
Compressor
Indoor Unit Outdoor Unit Outdoor Indoor Indoor & Outdoor
Cooling Heating Cooling Heating
Aluminum Fin - Copper Tube 18 1/4 inch 2 row / 16 step 2 row / 24 step 30 / 40 53 14 T 115 5 T 75 61 T 90 T 80 1/4" 1/2" 98 / 10 50
High side (flare) Low side (flare)
Type Control Method Factory Charge (oz.) Charged for Additional Refrigerant
R410A Electronic Expansion Valve 45.8 25 ft. 0.16 oz./ft. over 25 ft.
Manufacturer Type RLA (A)
Samsung DC, Inverter Driven, Rotary 6.2 Cooling (Hz)
15 / 72 / 82
Heating (Hz)
15 / 76 / 93
Evaporator Fan
Condenser Fan
Motor Output FLA
W Amps
Condensate pump Wired Controller Accessories
Standard Premium
Interface module for central control Wall bracket (for outdoor unit) Line sets - insulated and flared, interconnect cables included Certifications
Warranty
41 15/16 X 11 3/4 X 8 5/8 31 1/8 X 21 9/16 X 11 1/4 25 85 11/16" OD
Maximum / Minimum Line Set Length (ft.) Maximum Vertical Separation (ft.)
Operating Frequency (Low/Std./Max.)
Devices
AQN18VFUAGM
1 / 208-230 / 60 176 - 254 (max. 3% deviation from each) 2.2 / 8.9 / 9.5 2.0 / 8.8 / 10.5 15 9.0
(L/H) High
Type Air Volume (max. CFM) W Consumption Operating Current (A)
Safety
18,000 20,500 4,405 - 21,00 2,800 - 25,511 16.0 / 10.0 8.0 5.28
BLDC motor with cross-flow fan (1) 460 27 0.12 BLDC motor with axial fan (1) 39 0.17 ASP-MO-UNIV 110-250 AQN-WRS (includes sub-PCB and MWR-WH00 wired controller)
AQN-WRP (includes sub-PCB and MWR-WE10 wired controller with scheduling) MIM-B13D CKN-250 25' - ILS2507 50' - ILS5007 ETL & ETLc
PCB fuses, indoor unit terminal block thermal fuse, current transformer, overvoltage protection, crankcase heating, temperature limit protection logic, compressor overload sensing
AQX18VFUAGM • Low ambient control built in • Outdoor unit shall provide 208/230V power to indoor unit via 14 AWG X 3 interconnect power cable • Electro-static, washable, HD (high density) main filter as standard Construction Indoor unit chassis shall be UL94 V0 with a galvanized steel mounting bracket The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube Refrigerant System The compressor shall be hermetically sealed, inverter controlled, Twin BLDC Rotary Refrigerant flow shall be controlled by EEV (electronic expansion valve) at outdoor unit Indoor Fan The indoor fan shall be a single, antibacterial cross-flow type Three fan speed settings and auto setting Controls Control signal shall be DDC type signal Interconnect control wiring shall be 16 AWG X 2 shielded wire between outdoor and indoor units Unit shall be operated via wireless controller (included) Optional wired control available Contact Quietside for details regarding central control applications, capabilities, and limitations Convenience • Auto restart • Turbo mode (during cooling operation only) • Auto changeover • 24 hour timer • Good'sleep mode • Quiet mode • Dry mode
5 Years compressor, 3 Year Parts, 120 Day limited labor Nominal cooling capacities are based on: Indoor temperature: 80ͼF DB, 67ͼF WB. Outdoor temperature: 95ͼF DB, 75ͼF WB. Nominal heating capacities are based on: Indoor temperature: 70ͼF DB, 60ͼF WB. Outdoor temperature: 47ͼF DB, 43ͼF WB. Quietside maintains a policy of ongoing development, specifications are subject to change without notice. Refer to www.AHRIdirectory.org for current reference numbers.
www.Quietside.com
QS-RAC-A
Page 2 of 3
SUBMITTAL AQNVFUAGM / AQXVFUAGM
www.Quietside.com
AQNVFUA Max, wall mounted evaporator, single zone split system
Page of 3
SUBMITTAL AQNVFUAGM / AQXVFUAGM
www.Quietside.com
AQNVFUA Max, wall mounted evaporator, single zone split system
For reference only. Always refer to installation manual for complete details.
Indoor Unit
Minimum clearance from walls and ceiling 11 3/4" minimum
L1 5" minimum
L2
F1
F2
L1 L2
F1
F2
5" minimum
24" minimum 12" minimum 12" minimum
F1
F2 L1
Minimum clearance from nearby obstructions
L2
Communication
24" minimum
Main Power
Outdoor Unit