Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 LM-79-08 Test Report For MAXLITE INC (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006 Parking Garage Luminaires Representative (Tested) Model: CD60UT550xxxxx Model Different: N/A Test & Report By: Review By: Johnson Sun Engineer: Johnson Sun Manager: Tommy Liang Date: July.07,2015 Update:Sep.22,2015 Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 1 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 U.S. Department of Energy Lighting FactsTM Uniform LM-79 Reporting Template Laboratory Information: Name of Test Laboratory Standard-Tech Co., Ltd. Date of Test Report July.07,2015 Test Report No. STD150606NB-B3-P Laboratory Contact Name Tommy Liang Product Information: Organization Name MAXLITE INC Brand Name N/A Model Number CD60UT550xxxxx SKU (if available) N/A Type of Luminaire (for integral lamps, list base type and lamp type) Parking Garage Luminaires Luminaire Aperture (for downlights) -- in. Luminaire Length -- mm Luminaires Width -- mm Number of Units (modular products) N/A s Integrating Sphere Goniophotometer Output Output Electrical Measurements: Input Wattage 60.13 W Input Current 0.5093 A Input Voltage (ac) 120.0 V Power Factor 0.9839 Off-State Power 0 W Total Initial Lumen Output 6112.3 lm Initial Lumen Efficacy 101.66 lm/w K Photometric Characteristics Correlated color temperature / CCT 5075 -- Color rendering index / CRI 84.6 -- 22 -- 0.0014 -- R9 Value Duv Luminous Intensity Distribution Center beam candlepower (if applicable) 589 cd 158.1 ° 55.4 % 43 % Zonal lumens in the 90°-120°zone 1.5 % Zonal lumens in the 120°-180°zone 0.1 % Beam angle (if applicable) Zonal lumens in the 0°-60°zone ----- Zonal lumens in the 60°-90°zone Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 2 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 Test Specifications: Date of Receipt : Jun.27,2015 Date of Test : July.07,2015 Test item : Total Luminous Flux, Luminous Distribution Intensity, Luminous Efficacy, Correlated Color Temperature, Color Rendering Index, Chromaticity Coordinate, Electrical parameters Reference Standard IES LM-79-2008 Electrical and Photometric Measurements of Solid-State Lighting Products ANSI C78.377-2008 Specifications for the Chromaticity of Solid State Lighting Products CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering Properties of Light Sources CIE 15-2004 Technical Report Colorimetry IESNA LM-16-93 Practical Guide to Colorimetry of Light Source IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED) Sources and Systems Reference Work QD25 Instruction Test Methods 1. Photometric and Electrical measurements – Light Distribution Method: Photometric parameters were measured using the goniophotometer and software. The ambient temperature shall be maintained at 25°C ±1°C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 Volts AC, 60Hz. It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 1°vertical intervals and 22.5°horizontal intervals. 2. Photometric and Electrical Measurements – Integrating Sphere Method: Photometric parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25ºC ±1ºC. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral radiant flux measurements taken at least 5 nm intervals over the range of 380 to 780 nm. Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 3 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 1. Product Information: Brand Name N/A Model Number CD60UT550xxxxx Luminaire Type Parking Garage Luminaires Rated Voltage / Frequency 120~ 277Vac, 50/60Hz Nominal Power 60W Rated Initial Lamp Lumen -- Declared CCT 5000K LED Manufacturer Cree,Inc. Sample Receipt Date Jun.27,2015 Sample Number STD150606NB-B2(5000K) Photo Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 4 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 2.1 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) IES LM-79 2008 Test date 2015-06-27 Test Ambient: 25.2 ºC Test Orientation As intended Stabilization Time (min) 90 Model Number CD60UT550xxxxx Electrical Measurement: Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % STD150606 120.0 60 0.5093 60.13 0.9839 16.34 NB-B2 277.0 60 0.2385 61.20 0.9262 18.15 Sphere-Spectroradiometer Method: Parameter Result Test Voltage (V) 120.0 R1 84 R9 22 Frequency (Hz) 60 R2 88 R10 71 84.6 R3 91 R11 85 22 R4 86 R12 64 5075 R5 85 R13 85 Color Rendering Index (CRI) R9 CCT (K) Chromaticity (x, y) Chromaticity (u’, v’) Special Color Rendering Indices x=0.3433 y=0.3529 R6 84 R14 95 u’,=0.2097 v’=0.4850 R7 88 R15 80 R8 73 -- -- Duv 0.0014 Goniophotometer Method: Parameter Result Test Voltage (V) 120.0 Frequency (Hz) 60 Total Luminous (lm) 6112.3 Luminous Efficacy (lm/W) 101.66 Beam Angle° 158.1 Center Beam Candle Power (cd) 589 S/MH(C0/180) 2.54 S/MH(C90/270) 2.47 Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 5 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 Spectral Power Distribution & Chromaticity Diagram Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 6 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 Zonal Lumen Tabulation Zonal Lumen Summary Zone Lumens % Luminaire 0-30 618.6 10.1% 0-40 1,212.5 19.8% 0-60 3,387.6 55.4% 60-90 2,629.9 43% 70-100 1,332.7 21.8% 90-120 0-90 90.3 1.5% 6,017.5 98.5% 94.6 1.5% 6,112.1 100% 90-180 0-180 Lumens Per Zone Zone Lumens % Total Zone Lumens % Total 0-10 58.7 1.0% 90-100 52.1 0.9% 10-20 192.0 3.1% 100-110 33.1 0.5% 20-30 367.9 6.0% 110-120 5.2 0.1% 30-40 594.0 9.7% 120-130 1.5 0% 40-50 914.2 15.0% 130-140 1.1 0% 50-60 1,260.9 20.6% 140-150 0.8 0% 60-70 1,349.3 22.1% 150-160 0.5 0% 70-80 978.2 16.0% 160-170 0.3 0% 80-90 302.4 4.9% 170-180 0.1 0% Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 7 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 Photometric Data Illuminance Plots Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 8 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 ISOCANDELA DIAGRAM ISOLUX DIAGRAM Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 9 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 Candela Table - Type C 0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360 0 589 589 589 589 589 589 589 589 589 589 589 589 589 589 589 589 589 1 590 587 584 582 586 585 585 588 590 593 594 597 597 596 597 595 590 2 593 587 583 579 589 585 587 591 594 596 599 603 606 606 605 601 593 3 594 590 587 582 595 591 594 596 595 596 602 611 615 612 608 604 594 4 599 596 595 588 602 601 601 600 599 595 603 613 621 615 609 607 599 5 605 604 604 595 612 612 610 606 602 597 604 614 627 617 611 611 605 6 610 613 614 603 624 618 617 610 602 596 603 613 630 622 615 615 610 7 614 624 622 609 631 625 621 609 604 596 603 616 631 625 619 616 614 8 618 627 626 615 635 630 626 610 605 601 609 619 634 631 622 615 618 9 621 630 629 618 637 632 632 614 604 606 618 626 639 641 623 612 621 10 627 631 631 622 641 634 636 616 603 616 627 635 650 653 627 615 627 11 636 634 631 622 643 638 640 624 607 629 639 641 660 667 638 623 636 12 647 638 633 625 646 645 645 637 615 639 653 648 668 680 651 636 647 13 658 646 640 627 650 651 651 650 624 653 665 658 678 694 658 647 658 14 672 653 648 629 656 664 658 662 633 664 676 667 683 701 662 654 672 15 688 662 659 635 660 678 668 675 641 675 689 675 694 706 664 661 688 16 702 670 676 644 672 689 684 685 644 683 699 687 703 705 670 669 702 17 716 675 690 655 686 701 698 696 652 690 708 702 711 709 679 678 716 18 724 682 699 667 701 715 705 707 662 694 717 718 724 713 690 688 724 19 728 687 711 676 710 729 710 711 671 704 731 733 738 724 705 700 728 20 736 692 724 688 717 743 717 716 685 718 741 751 754 738 726 717 736 21 741 705 731 698 721 752 729 722 703 733 749 772 773 751 744 733 741 22 752 721 737 703 729 762 745 731 723 747 760 792 786 762 762 750 752 23 766 742 744 713 744 772 764 747 745 763 771 811 799 773 782 762 766 24 778 764 754 730 762 784 785 762 767 775 781 829 811 786 801 772 778 25 794 782 763 746 780 796 805 776 785 791 788 849 822 800 815 782 794 26 804 804 772 765 794 805 824 789 803 801 798 869 836 810 829 795 804 27 815 824 779 784 803 814 843 799 814 813 808 888 852 819 848 807 815 28 826 841 788 801 815 824 861 813 823 825 824 899 861 830 862 818 826 29 837 858 798 815 827 837 880 824 833 833 839 905 874 846 876 828 837 Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 10 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 30 844 869 809 826 838 847 897 833 841 841 855 911 885 861 882 842 844 31 857 888 818 844 853 858 914 838 844 852 875 922 899 879 891 856 857 32 872 910 823 856 865 872 929 848 849 863 899 932 917 899 894 871 872 33 889 922 835 868 878 886 947 862 855 874 916 948 939 920 905 889 889 34 910 929 850 879 898 901 966 875 864 886 931 961 964 941 919 907 910 35 932 941 865 891 917 916 975 893 878 903 948 983 987 958 928 931 932 36 949 950 883 906 937 943 989 913 901 932 966 1048 1000 978 947 953 949 37 965 960 906 921 963 969 997 933 924 966 990 1140 1013 1005 998 971 965 38 990 977 924 946 995 995 1007 954 954 991 1019 1229 1019 1038 1094 990 990 39 1007 997 941 977 1030 1016 1016 981 994 1018 1056 1266 1024 1069 1176 1006 1007 40 1028 1033 963 1009 1062 1043 1032 1013 1040 1052 1103 1249 1038 1099 1227 1022 1028 41 1054 1102 987 1037 1089 1074 1076 1048 1081 1080 1158 1190 1064 1127 1250 1045 1054 42 1078 1168 1017 1062 1109 1101 1176 1084 1115 1092 1202 1139 1089 1169 1230 1073 1078 43 1097 1212 1059 1092 1116 1129 1272 1117 1124 1101 1236 1123 1117 1216 1173 1107 1097 44 1123 1237 1106 1114 1120 1155 1294 1153 1128 1128 1265 1148 1140 1272 1121 1138 1123 45 1146 1260 1154 1145 1124 1184 1297 1188 1147 1163 1284 1194 1152 1315 1101 1169 1146 46 1165 1233 1196 1173 1130 1219 1283 1223 1172 1179 1304 1232 1167 1342 1133 1201 1165 47 1188 1178 1224 1182 1153 1257 1236 1260 1184 1173 1317 1246 1180 1360 1204 1233 1188 48 1217 1133 1245 1180 1181 1291 1183 1286 1192 1151 1325 1242 1199 1368 1256 1258 1217 49 1245 1114 1284 1178 1202 1329 1155 1313 1180 1129 1332 1253 1223 1398 1257 1277 1245 50 1268 1155 1323 1186 1216 1362 1190 1337 1168 1135 1357 1294 1253 1446 1255 1296 1268 51 1276 1225 1335 1195 1236 1386 1257 1365 1181 1189 1393 1349 1291 1508 1287 1342 1276 52 1286 1270 1344 1184 1245 1395 1309 1393 1218 1281 1438 1405 1326 1561 1333 1387 1286 53 1301 1276 1361 1168 1259 1403 1305 1434 1272 1357 1470 1448 1354 1592 1356 1417 1301 54 1334 1291 1388 1151 1288 1432 1304 1499 1317 1441 1491 1483 1374 1614 1346 1440 1334 55 1354 1330 1434 1144 1325 1482 1376 1562 1358 1525 1514 1493 1387 1613 1311 1455 1354 56 1381 1352 1507 1184 1354 1526 1447 1602 1403 1585 1528 1477 1402 1590 1276 1496 1381 57 1406 1372 1589 1260 1372 1542 1469 1611 1440 1609 1522 1454 1409 1584 1255 1535 1406 58 1431 1373 1638 1343 1394 1556 1436 1586 1467 1583 1524 1434 1400 1623 1252 1561 1431 59 1445 1348 1623 1433 1424 1577 1371 1585 1466 1539 1548 1407 1377 1676 1268 1580 1445 60 1454 1316 1597 1496 1454 1587 1319 1590 1438 1486 1570 1355 1339 1677 1290 1608 1454 61 1467 1304 1581 1541 1490 1600 1295 1628 1396 1437 1535 1333 1354 1608 1293 1617 1467 Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 11 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 62 1468 1323 1567 1564 1509 1631 1308 1661 1344 1412 1444 1354 1375 1518 1266 1590 1468 63 1472 1336 1564 1555 1504 1648 1327 1638 1319 1403 1343 1324 1387 1426 1220 1562 1472 64 1484 1314 1553 1513 1463 1648 1334 1582 1332 1370 1256 1289 1394 1325 1179 1537 1484 65 1513 1276 1539 1449 1415 1643 1323 1517 1342 1340 1189 1250 1362 1258 1124 1507 1513 66 1511 1220 1501 1393 1390 1607 1298 1441 1339 1312 1144 1163 1348 1212 1082 1482 1511 67 1475 1167 1439 1349 1392 1509 1288 1392 1321 1258 1125 1091 1352 1185 1038 1428 1475 68 1400 1139 1355 1330 1402 1430 1230 1349 1303 1196 1130 1036 1338 1196 990 1373 1400 69 1340 1104 1269 1316 1375 1358 1205 1302 1308 1147 1132 1001 1322 1172 958 1303 1340 70 1306 1083 1204 1271 1365 1305 1145 1252 1326 1112 1120 965 1268 1108 924 1241 1306 71 1293 1062 1164 1225 1337 1266 1076 1213 1315 1098 1081 943 1209 1100 887 1182 1293 72 1282 1032 1141 1180 1336 1241 1032 1175 1225 1071 1020 900 1119 1074 867 1124 1282 73 1225 996 1109 1121 1375 1219 987 1145 1138 990 951 842 1006 1011 873 1091 1225 74 1148 949 1067 1067 1418 1155 933 1118 1068 884 868 772 909 932 871 1065 1148 75 1092 915 1050 1000 1334 1121 918 1085 1003 818 771 683 807 831 857 1027 1092 76 1045 906 1053 953 1216 1111 938 1038 934 758 669 578 686 711 801 950 1045 77 976 908 1035 951 1131 1088 910 954 827 665 554 469 568 598 695 827 976 78 865 884 986 948 1058 1020 853 829 681 548 446 381 470 489 573 695 865 79 729 817 914 904 974 924 794 690 546 442 373 323 390 399 485 567 729 80 594 712 824 838 862 789 680 571 449 370 323 280 333 340 406 458 594 81 488 591 696 747 724 660 560 470 375 322 284 245 289 299 343 382 488 82 404 479 573 639 602 554 469 392 325 285 249 214 253 260 294 330 404 83 343 396 469 535 506 463 395 340 287 252 217 186 218 224 251 287 343 84 295 340 391 446 423 391 342 298 252 223 188 160 189 193 218 248 295 85 254 295 338 373 362 337 300 261 223 197 162 140 165 167 191 213 254 86 219 255 295 320 312 292 261 228 195 173 140 124 143 145 167 184 219 87 188 218 254 278 268 249 228 196 168 149 125 111 126 127 144 160 188 88 162 189 216 240 231 213 197 167 145 130 115 102 113 114 124 140 162 89 140 163 184 205 195 179 167 140 128 114 106 99 105 104 108 122 140 90 121 141 157 174 163 149 137 106 103 93 96 97 102 100 97 106 121 91 101 116 129 145 136 125 110 45 68 59 92 92 104 99 88 89 101 92 83 89 108 120 112 98 65 3 9 4 79 94 101 94 81 73 83 93 42 33 83 97 85 67 18 3 2 2 40 88 103 95 76 18 42 Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 12 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 94 1 2 41 69 52 30 2 24 6 10 7 64 104 92 52 1 1 95 1 1 5 36 17 4 3 89 54 78 2 25 88 71 17 1 1 96 11 24 1 6 2 2 3 88 100 92 2 3 51 32 1 44 11 97 79 69 1 1 2 3 7 72 92 74 3 2 10 5 1 93 79 98 88 63 2 1 3 10 9 50 73 48 3 2 1 8 1 87 88 99 78 49 5 9 12 14 5 30 48 23 3 4 2 11 2 66 78 100 60 32 3 14 17 30 4 15 26 8 4 11 3 14 1 40 60 101 37 18 3 24 32 71 6 6 10 2 5 30 4 17 1 16 37 102 18 7 5 60 71 118 11 2 9 2 7 57 5 20 1 4 18 103 5 2 9 105 118 139 19 2 9 2 11 72 6 49 3 1 5 104 1 1 15 126 139 144 28 2 9 2 15 67 27 73 6 1 1 105 1 1 25 128 138 144 37 2 8 2 17 49 47 77 9 1 1 106 1 1 37 126 134 139 43 2 8 2 17 32 47 60 10 1 1 107 1 1 48 122 125 126 46 2 7 2 13 18 29 39 10 1 1 108 1 1 53 111 110 108 43 2 7 2 6 7 14 20 8 1 1 109 1 1 50 96 89 84 35 2 6 2 2 2 3 7 5 1 1 110 1 2 43 76 67 63 27 2 6 2 2 2 2 3 3 1 1 111 1 2 35 56 46 42 21 2 5 2 2 2 2 3 2 2 1 112 1 2 26 37 26 23 10 2 5 2 2 2 2 3 2 2 1 113 1 2 14 21 12 8 4 2 4 2 2 2 2 3 2 2 1 114 1 2 5 10 4 3 2 2 4 2 2 2 2 3 2 2 1 115 1 2 2 3 2 3 2 2 4 2 2 2 2 3 2 2 1 116 2 2 2 2 2 3 2 2 3 2 2 2 2 3 2 2 2 117 2 2 2 2 2 3 2 2 3 2 2 2 2 3 2 2 2 118 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 119 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 120 2 2 1 2 2 2 2 2 2 2 1 2 2 2 2 2 2 121 2 2 1 2 2 2 2 2 2 2 1 2 2 2 2 2 2 122 2 2 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 123 2 2 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 124 2 2 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 125 2 2 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 13 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 126 2 2 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 127 2 2 2 2 2 2 2 2 2 2 1 2 1 2 2 2 2 128 2 2 2 2 2 2 1 2 2 2 1 2 1 2 2 2 2 129 2 2 2 2 2 2 1 2 2 2 1 2 1 2 2 2 2 130 2 2 2 2 2 2 1 2 2 2 1 1 1 2 2 2 2 131 2 2 2 2 2 2 1 2 2 2 1 1 1 2 1 2 2 132 1 2 2 2 2 2 1 2 2 2 1 1 1 2 1 2 1 133 1 2 2 2 2 2 1 2 2 2 1 1 1 1 1 1 1 134 1 2 1 2 2 1 1 2 2 2 1 1 1 1 1 2 1 135 1 1 1 2 2 1 1 1 2 2 1 1 1 1 1 1 1 136 1 1 1 2 2 1 1 1 2 2 1 1 1 1 1 1 1 137 1 1 1 2 2 1 1 1 2 2 1 1 1 1 1 1 1 138 1 1 1 2 2 1 1 1 2 2 1 1 1 1 1 1 1 139 1 1 1 1 2 1 1 1 2 2 1 1 1 1 1 1 1 140 1 1 1 1 2 1 1 1 2 2 1 1 1 1 1 1 1 141 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 142 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 143 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 144 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 145 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 146 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 147 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 148 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 149 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 150 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 151 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 152 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 153 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 154 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 155 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 156 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 157 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 14 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 158 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 159 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 160 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 161 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 162 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 163 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 164 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 165 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 166 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 167 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 168 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 169 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 170 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 171 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 172 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 173 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 174 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 175 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 176 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 177 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 178 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 179 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 180 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 15 / 16 Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 3. Test Equipment Equipment ID Equipment Name Last Calibration Date Next Calibration Date ST-R-336 2 meter Integrating Sphere 2015-07-01 2016-06-30 ST-R-331 Spectral analysis system HAAS-2000 2015-07-01 2016-06-30 D204 Standard Lamp 2015-07-01 2016-06-30 PF2010 Power Meter for Integrating Sphere 2015-07-01 2016-06-30 EE-09 Goniophotometer system 2015-07-01 2016-06-30 D908S Standard Lamp 2015-07-01 2016-06-30 PF210 Power Meter for Goniophotometer 2015-07-01 2016-06-30 ST-R-181A Temperature Tester 2015-07-01 2016-06-30 Uncertainty Photometric Measurement (Sphere):1.74% Chromaticity Measurement(Sphere):14.3K Photometric Measurement(Goniophotometer):1.62% ****** END OF DATASHEET PACKAGE ****** Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 16 / 16