Transcript
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0
LM-79-08 Test Report For
MAXLITE INC (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006
Parking Garage Luminaires Representative (Tested) Model: CD60UT550xxxxx
Model Different: N/A Test & Report By:
Review By:
Johnson Sun Engineer: Johnson Sun
Manager: Tommy Liang
Date: July.07,2015 Update:Sep.22,2015
Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
1 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 U.S. Department of Energy
Lighting FactsTM Uniform LM-79 Reporting Template Laboratory Information: Name of Test Laboratory
Standard-Tech Co., Ltd.
Date of Test Report
July.07,2015
Test Report No.
STD150606NB-B3-P
Laboratory Contact Name
Tommy Liang
Product Information: Organization Name
MAXLITE INC
Brand Name
N/A
Model Number
CD60UT550xxxxx
SKU (if available)
N/A
Type of Luminaire (for integral lamps, list base type and lamp type)
Parking Garage Luminaires
Luminaire Aperture (for downlights)
--
in.
Luminaire Length
--
mm
Luminaires Width
--
mm
Number of Units (modular products)
N/A
s
Integrating Sphere
Goniophotometer
Output
Output
Electrical Measurements: Input Wattage
60.13
W
Input Current
0.5093
A
Input Voltage (ac)
120.0
V
Power Factor
0.9839
Off-State Power
0
W
Total Initial Lumen Output
6112.3
lm
Initial Lumen Efficacy
101.66
lm/w K
Photometric Characteristics
Correlated color temperature / CCT
5075
--
Color rendering index / CRI
84.6
--
22
--
0.0014
--
R9 Value Duv Luminous Intensity Distribution Center beam candlepower (if applicable)
589
cd
158.1
°
55.4
%
43
%
Zonal lumens in the 90°-120°zone
1.5
%
Zonal lumens in the 120°-180°zone
0.1
%
Beam angle (if applicable) Zonal lumens in the 0°-60°zone
-----
Zonal lumens in the 60°-90°zone
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
2 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 Test Specifications: Date of Receipt
: Jun.27,2015
Date of Test
: July.07,2015
Test item
: Total Luminous Flux, Luminous Distribution Intensity, Luminous Efficacy, Correlated Color Temperature, Color Rendering Index, Chromaticity Coordinate, Electrical parameters
Reference Standard
IES LM-79-2008 Electrical and Photometric Measurements of Solid-State Lighting Products ANSI C78.377-2008 Specifications for the Chromaticity of Solid State Lighting Products CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering Properties of Light Sources CIE 15-2004 Technical Report Colorimetry IESNA LM-16-93 Practical Guide to Colorimetry of Light Source IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED) Sources and Systems
Reference Work
QD25
Instruction
Test Methods 1. Photometric and Electrical measurements – Light Distribution Method: Photometric parameters were measured using the goniophotometer and software. The ambient temperature shall be maintained at 25°C ±1°C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 Volts AC, 60Hz. It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 1°vertical intervals and 22.5°horizontal intervals. 2. Photometric and Electrical Measurements – Integrating Sphere Method: Photometric parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25ºC ±1ºC. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral radiant flux measurements taken at least 5 nm intervals over the range of 380 to 780 nm.
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
3 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0
1. Product Information: Brand Name
N/A
Model Number
CD60UT550xxxxx
Luminaire Type
Parking Garage Luminaires
Rated Voltage / Frequency
120~ 277Vac, 50/60Hz
Nominal Power
60W
Rated Initial Lamp Lumen
--
Declared CCT
5000K
LED Manufacturer
Cree,Inc.
Sample Receipt Date
Jun.27,2015
Sample Number
STD150606NB-B2(5000K) Photo
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
4 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0
2.1 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25)
IES LM-79 2008
Test date
2015-06-27
Test Ambient:
25.2 ºC
Test Orientation
As intended
Stabilization Time (min)
90
Model Number
CD60UT550xxxxx
Electrical Measurement: Sample No.
Voltage (Vac)
Frequency (Hz )
Current (A)
Power (W)
Power Factor
THD %
STD150606
120.0
60
0.5093
60.13
0.9839
16.34
NB-B2
277.0
60
0.2385
61.20
0.9262
18.15
Sphere-Spectroradiometer Method: Parameter
Result
Test Voltage (V)
120.0
R1
84
R9
22
Frequency (Hz)
60
R2
88
R10
71
84.6
R3
91
R11
85
22
R4
86
R12
64
5075
R5
85
R13
85
Color Rendering Index (CRI) R9 CCT (K) Chromaticity (x, y) Chromaticity (u’, v’)
Special Color Rendering Indices
x=0.3433
y=0.3529
R6
84
R14
95
u’,=0.2097
v’=0.4850
R7
88
R15
80
R8
73
--
--
Duv
0.0014
Goniophotometer Method: Parameter
Result
Test Voltage (V)
120.0
Frequency (Hz)
60
Total Luminous (lm)
6112.3
Luminous Efficacy (lm/W)
101.66
Beam Angle°
158.1
Center Beam Candle Power (cd)
589
S/MH(C0/180)
2.54
S/MH(C90/270)
2.47
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
5 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0
Spectral Power Distribution & Chromaticity Diagram
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
6 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0
Zonal Lumen Tabulation Zonal Lumen Summary Zone
Lumens % Luminaire
0-30
618.6
10.1%
0-40
1,212.5
19.8%
0-60
3,387.6
55.4%
60-90
2,629.9
43%
70-100 1,332.7
21.8%
90-120 0-90
90.3
1.5%
6,017.5
98.5%
94.6
1.5%
6,112.1
100%
90-180 0-180
Lumens Per Zone Zone Lumens % Total Zone
Lumens % Total
0-10
58.7
1.0% 90-100
52.1
0.9%
10-20
192.0
3.1% 100-110
33.1
0.5%
20-30
367.9
6.0% 110-120
5.2
0.1%
30-40
594.0
9.7% 120-130
1.5
0%
40-50
914.2
15.0% 130-140
1.1
0%
50-60 1,260.9
20.6% 140-150
0.8
0%
60-70 1,349.3
22.1% 150-160
0.5
0%
70-80
978.2
16.0% 160-170
0.3
0%
80-90
302.4
4.9% 170-180
0.1
0%
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
7 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0
Photometric Data
Illuminance Plots
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
8 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0
ISOCANDELA DIAGRAM
ISOLUX DIAGRAM
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
9 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 Candela Table - Type C 0
22.5
45
67.5
90
112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360
0
589
589
589
589
589
589
589
589
589
589
589
589
589
589
589
589
589
1
590
587
584
582
586
585
585
588
590
593
594
597
597
596
597
595
590
2
593
587
583
579
589
585
587
591
594
596
599
603
606
606
605
601
593
3
594
590
587
582
595
591
594
596
595
596
602
611
615
612
608
604
594
4
599
596
595
588
602
601
601
600
599
595
603
613
621
615
609
607
599
5
605
604
604
595
612
612
610
606
602
597
604
614
627
617
611
611
605
6
610
613
614
603
624
618
617
610
602
596
603
613
630
622
615
615
610
7
614
624
622
609
631
625
621
609
604
596
603
616
631
625
619
616
614
8
618
627
626
615
635
630
626
610
605
601
609
619
634
631
622
615
618
9
621
630
629
618
637
632
632
614
604
606
618
626
639
641
623
612
621
10
627
631
631
622
641
634
636
616
603
616
627
635
650
653
627
615
627
11
636
634
631
622
643
638
640
624
607
629
639
641
660
667
638
623
636
12
647
638
633
625
646
645
645
637
615
639
653
648
668
680
651
636
647
13
658
646
640
627
650
651
651
650
624
653
665
658
678
694
658
647
658
14
672
653
648
629
656
664
658
662
633
664
676
667
683
701
662
654
672
15
688
662
659
635
660
678
668
675
641
675
689
675
694
706
664
661
688
16
702
670
676
644
672
689
684
685
644
683
699
687
703
705
670
669
702
17
716
675
690
655
686
701
698
696
652
690
708
702
711
709
679
678
716
18
724
682
699
667
701
715
705
707
662
694
717
718
724
713
690
688
724
19
728
687
711
676
710
729
710
711
671
704
731
733
738
724
705
700
728
20
736
692
724
688
717
743
717
716
685
718
741
751
754
738
726
717
736
21
741
705
731
698
721
752
729
722
703
733
749
772
773
751
744
733
741
22
752
721
737
703
729
762
745
731
723
747
760
792
786
762
762
750
752
23
766
742
744
713
744
772
764
747
745
763
771
811
799
773
782
762
766
24
778
764
754
730
762
784
785
762
767
775
781
829
811
786
801
772
778
25
794
782
763
746
780
796
805
776
785
791
788
849
822
800
815
782
794
26
804
804
772
765
794
805
824
789
803
801
798
869
836
810
829
795
804
27
815
824
779
784
803
814
843
799
814
813
808
888
852
819
848
807
815
28
826
841
788
801
815
824
861
813
823
825
824
899
861
830
862
818
826
29
837
858
798
815
827
837
880
824
833
833
839
905
874
846
876
828
837
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
10 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 30
844
869
809
826
838
847
897
833
841
841
855
911
885
861
882
842
844
31
857
888
818
844
853
858
914
838
844
852
875
922
899
879
891
856
857
32
872
910
823
856
865
872
929
848
849
863
899
932
917
899
894
871
872
33
889
922
835
868
878
886
947
862
855
874
916
948
939
920
905
889
889
34
910
929
850
879
898
901
966
875
864
886
931
961
964
941
919
907
910
35
932
941
865
891
917
916
975
893
878
903
948
983
987
958
928
931
932
36
949
950
883
906
937
943
989
913
901
932
966 1048 1000
978
947
953
949
37
965
960
906
921
963
969
997
933
924
966
990 1140 1013 1005
998
971
965
38
990
977
924
946
995
995 1007
954
954
991 1019 1229 1019 1038 1094
990
990
39 1007
997
941
977 1030 1016 1016
981
994 1018 1056 1266 1024 1069 1176 1006 1007
40 1028 1033
963 1009 1062 1043 1032 1013 1040 1052 1103 1249 1038 1099 1227 1022 1028
41 1054 1102
987 1037 1089 1074 1076 1048 1081 1080 1158 1190 1064 1127 1250 1045 1054
42 1078 1168 1017 1062 1109 1101 1176 1084 1115 1092 1202 1139 1089 1169 1230 1073 1078 43 1097 1212 1059 1092 1116 1129 1272 1117 1124 1101 1236 1123 1117 1216 1173 1107 1097 44 1123 1237 1106 1114 1120 1155 1294 1153 1128 1128 1265 1148 1140 1272 1121 1138 1123 45 1146 1260 1154 1145 1124 1184 1297 1188 1147 1163 1284 1194 1152 1315 1101 1169 1146 46 1165 1233 1196 1173 1130 1219 1283 1223 1172 1179 1304 1232 1167 1342 1133 1201 1165 47 1188 1178 1224 1182 1153 1257 1236 1260 1184 1173 1317 1246 1180 1360 1204 1233 1188 48 1217 1133 1245 1180 1181 1291 1183 1286 1192 1151 1325 1242 1199 1368 1256 1258 1217 49 1245 1114 1284 1178 1202 1329 1155 1313 1180 1129 1332 1253 1223 1398 1257 1277 1245 50 1268 1155 1323 1186 1216 1362 1190 1337 1168 1135 1357 1294 1253 1446 1255 1296 1268 51 1276 1225 1335 1195 1236 1386 1257 1365 1181 1189 1393 1349 1291 1508 1287 1342 1276 52 1286 1270 1344 1184 1245 1395 1309 1393 1218 1281 1438 1405 1326 1561 1333 1387 1286 53 1301 1276 1361 1168 1259 1403 1305 1434 1272 1357 1470 1448 1354 1592 1356 1417 1301 54 1334 1291 1388 1151 1288 1432 1304 1499 1317 1441 1491 1483 1374 1614 1346 1440 1334 55 1354 1330 1434 1144 1325 1482 1376 1562 1358 1525 1514 1493 1387 1613 1311 1455 1354 56 1381 1352 1507 1184 1354 1526 1447 1602 1403 1585 1528 1477 1402 1590 1276 1496 1381 57 1406 1372 1589 1260 1372 1542 1469 1611 1440 1609 1522 1454 1409 1584 1255 1535 1406 58 1431 1373 1638 1343 1394 1556 1436 1586 1467 1583 1524 1434 1400 1623 1252 1561 1431 59 1445 1348 1623 1433 1424 1577 1371 1585 1466 1539 1548 1407 1377 1676 1268 1580 1445 60 1454 1316 1597 1496 1454 1587 1319 1590 1438 1486 1570 1355 1339 1677 1290 1608 1454 61 1467 1304 1581 1541 1490 1600 1295 1628 1396 1437 1535 1333 1354 1608 1293 1617 1467
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
11 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 62 1468 1323 1567 1564 1509 1631 1308 1661 1344 1412 1444 1354 1375 1518 1266 1590 1468 63 1472 1336 1564 1555 1504 1648 1327 1638 1319 1403 1343 1324 1387 1426 1220 1562 1472 64 1484 1314 1553 1513 1463 1648 1334 1582 1332 1370 1256 1289 1394 1325 1179 1537 1484 65 1513 1276 1539 1449 1415 1643 1323 1517 1342 1340 1189 1250 1362 1258 1124 1507 1513 66 1511 1220 1501 1393 1390 1607 1298 1441 1339 1312 1144 1163 1348 1212 1082 1482 1511 67 1475 1167 1439 1349 1392 1509 1288 1392 1321 1258 1125 1091 1352 1185 1038 1428 1475 68 1400 1139 1355 1330 1402 1430 1230 1349 1303 1196 1130 1036 1338 1196
990 1373 1400
69 1340 1104 1269 1316 1375 1358 1205 1302 1308 1147 1132 1001 1322 1172
958 1303 1340
70 1306 1083 1204 1271 1365 1305 1145 1252 1326 1112 1120
965 1268 1108
924 1241 1306
71 1293 1062 1164 1225 1337 1266 1076 1213 1315 1098 1081
943 1209 1100
887 1182 1293
72 1282 1032 1141 1180 1336 1241 1032 1175 1225 1071 1020
900 1119 1074
867 1124 1282
73 1225
996 1109 1121 1375 1219
987 1145 1138
990
951
842 1006 1011
873 1091 1225
74 1148
949 1067 1067 1418 1155
933 1118 1068
884
868
772
909
932
871 1065 1148
75 1092
915 1050 1000 1334 1121
918 1085 1003
818
771
683
807
831
857 1027 1092
76 1045
906 1053
953 1216 1111
938 1038
934
758
669
578
686
711
801
950 1045
77
976
908 1035
951 1131 1088
910
954
827
665
554
469
568
598
695
827
976
78
865
884
986
948 1058 1020
853
829
681
548
446
381
470
489
573
695
865
79
729
817
914
904
974
924
794
690
546
442
373
323
390
399
485
567
729
80
594
712
824
838
862
789
680
571
449
370
323
280
333
340
406
458
594
81
488
591
696
747
724
660
560
470
375
322
284
245
289
299
343
382
488
82
404
479
573
639
602
554
469
392
325
285
249
214
253
260
294
330
404
83
343
396
469
535
506
463
395
340
287
252
217
186
218
224
251
287
343
84
295
340
391
446
423
391
342
298
252
223
188
160
189
193
218
248
295
85
254
295
338
373
362
337
300
261
223
197
162
140
165
167
191
213
254
86
219
255
295
320
312
292
261
228
195
173
140
124
143
145
167
184
219
87
188
218
254
278
268
249
228
196
168
149
125
111
126
127
144
160
188
88
162
189
216
240
231
213
197
167
145
130
115
102
113
114
124
140
162
89
140
163
184
205
195
179
167
140
128
114
106
99
105
104
108
122
140
90
121
141
157
174
163
149
137
106
103
93
96
97
102
100
97
106
121
91
101
116
129
145
136
125
110
45
68
59
92
92
104
99
88
89
101
92
83
89
108
120
112
98
65
3
9
4
79
94
101
94
81
73
83
93
42
33
83
97
85
67
18
3
2
2
40
88
103
95
76
18
42
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
12 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 94
1
2
41
69
52
30
2
24
6
10
7
64
104
92
52
1
1
95
1
1
5
36
17
4
3
89
54
78
2
25
88
71
17
1
1
96
11
24
1
6
2
2
3
88
100
92
2
3
51
32
1
44
11
97
79
69
1
1
2
3
7
72
92
74
3
2
10
5
1
93
79
98
88
63
2
1
3
10
9
50
73
48
3
2
1
8
1
87
88
99
78
49
5
9
12
14
5
30
48
23
3
4
2
11
2
66
78
100
60
32
3
14
17
30
4
15
26
8
4
11
3
14
1
40
60
101
37
18
3
24
32
71
6
6
10
2
5
30
4
17
1
16
37
102
18
7
5
60
71
118
11
2
9
2
7
57
5
20
1
4
18
103
5
2
9
105
118
139
19
2
9
2
11
72
6
49
3
1
5
104
1
1
15
126
139
144
28
2
9
2
15
67
27
73
6
1
1
105
1
1
25
128
138
144
37
2
8
2
17
49
47
77
9
1
1
106
1
1
37
126
134
139
43
2
8
2
17
32
47
60
10
1
1
107
1
1
48
122
125
126
46
2
7
2
13
18
29
39
10
1
1
108
1
1
53
111
110
108
43
2
7
2
6
7
14
20
8
1
1
109
1
1
50
96
89
84
35
2
6
2
2
2
3
7
5
1
1
110
1
2
43
76
67
63
27
2
6
2
2
2
2
3
3
1
1
111
1
2
35
56
46
42
21
2
5
2
2
2
2
3
2
2
1
112
1
2
26
37
26
23
10
2
5
2
2
2
2
3
2
2
1
113
1
2
14
21
12
8
4
2
4
2
2
2
2
3
2
2
1
114
1
2
5
10
4
3
2
2
4
2
2
2
2
3
2
2
1
115
1
2
2
3
2
3
2
2
4
2
2
2
2
3
2
2
1
116
2
2
2
2
2
3
2
2
3
2
2
2
2
3
2
2
2
117
2
2
2
2
2
3
2
2
3
2
2
2
2
3
2
2
2
118
2
2
2
2
2
2
2
2
2
2
2
2
2
3
2
2
2
119
2
2
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
120
2
2
1
2
2
2
2
2
2
2
1
2
2
2
2
2
2
121
2
2
1
2
2
2
2
2
2
2
1
2
2
2
2
2
2
122
2
2
2
2
2
2
2
2
2
2
1
2
2
2
2
2
2
123
2
2
2
2
2
2
2
2
2
2
1
2
2
2
2
2
2
124
2
2
2
2
2
2
2
2
2
2
1
2
2
2
2
2
2
125
2
2
2
2
2
2
2
2
2
2
1
2
2
2
2
2
2
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
13 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 126
2
2
2
2
2
2
2
2
2
2
1
2
2
2
2
2
2
127
2
2
2
2
2
2
2
2
2
2
1
2
1
2
2
2
2
128
2
2
2
2
2
2
1
2
2
2
1
2
1
2
2
2
2
129
2
2
2
2
2
2
1
2
2
2
1
2
1
2
2
2
2
130
2
2
2
2
2
2
1
2
2
2
1
1
1
2
2
2
2
131
2
2
2
2
2
2
1
2
2
2
1
1
1
2
1
2
2
132
1
2
2
2
2
2
1
2
2
2
1
1
1
2
1
2
1
133
1
2
2
2
2
2
1
2
2
2
1
1
1
1
1
1
1
134
1
2
1
2
2
1
1
2
2
2
1
1
1
1
1
2
1
135
1
1
1
2
2
1
1
1
2
2
1
1
1
1
1
1
1
136
1
1
1
2
2
1
1
1
2
2
1
1
1
1
1
1
1
137
1
1
1
2
2
1
1
1
2
2
1
1
1
1
1
1
1
138
1
1
1
2
2
1
1
1
2
2
1
1
1
1
1
1
1
139
1
1
1
1
2
1
1
1
2
2
1
1
1
1
1
1
1
140
1
1
1
1
2
1
1
1
2
2
1
1
1
1
1
1
1
141
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
142
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
143
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
144
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
145
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
146
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
147
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
148
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
149
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
150
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
151
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
152
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
153
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
154
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
155
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
156
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
157
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
14 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0 158
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
159
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
160
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
161
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
162
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
163
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
164
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
165
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
166
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
167
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
168
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
169
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
170
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
171
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
172
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
173
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
174
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
175
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
176
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
177
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
178
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
179
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
180
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
15 / 16
Report No.: STD150606NB-B3-P NVLAP LAB CODE 201011-0
3. Test Equipment Equipment ID
Equipment Name
Last Calibration Date
Next Calibration Date
ST-R-336
2 meter Integrating Sphere
2015-07-01
2016-06-30
ST-R-331
Spectral analysis system HAAS-2000
2015-07-01
2016-06-30
D204
Standard Lamp
2015-07-01
2016-06-30
PF2010
Power Meter for Integrating Sphere
2015-07-01
2016-06-30
EE-09
Goniophotometer system
2015-07-01
2016-06-30
D908S
Standard Lamp
2015-07-01
2016-06-30
PF210
Power Meter for Goniophotometer
2015-07-01
2016-06-30
ST-R-181A
Temperature Tester
2015-07-01
2016-06-30
Uncertainty Photometric Measurement (Sphere):1.74% Chromaticity Measurement(Sphere):14.3K Photometric Measurement(Goniophotometer):1.62%
****** END OF DATASHEET PACKAGE ******
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
16 / 16