Transcript
MED(EU Marine Equipment Directive) Certificate Number QQ-MED-07/03-01
Stable Speed Display in Dual Frequency Modes
The JLN-550 Doppler Sonar is designed to provide ship speed information with higher stability in the dual frequency modes; one using a lower ultrasonic frequency that is adequate to measure the ship’ s speed against the ground up to larger depths and the other using a higher ultrasonic frequency that allows the ship’ s speed against the water to be measured even in water with tiny bubbles. The transducer is designed for dual-frequency transmission, but its size is smaller than the conventional models. This equipment is designed to comply with the following standards:
(19) IMO A. 824 Revised MSC.96(72), IMO A.694 (1 7), IEC61023 : 1999, IEC60945 : 2002 and IEC61162-1 : 2000
FEATURES Ship speed measurement is insensible to bubbles generated in high-speed navigation, ensuring stable speed display. The transducer is substantially downsized, allowing it to be installed on the bow side that is little affected by bubbles. An underwater-mateable connector is adopted for the transducer, so that a transducer can be replaced at a quay even in case of its failure. The equipment is provided with an additional function of indicating the ship’ s fore and aft speeds and port and starboard speeds by entering GPS information. The ship’ s port and starboard speeds at its arbitrary position can be indicated by entering ROT information. An optimal Doppler sonar system can be configured by combining a variety of options. On-line maintenance (option) allows any failure to be detected during navigation.
SPECIFICATIONS Operating system
2-axis 4-beam pulse Doppler sonar or ROT-combined 3-axis 4-beam pulse Doppler sonar (ROT: option)
Operating frequencies
2 4 0kHz (BT: for speed against the ground) 2MHz (WT: for speed against the water)
Speed range
0.0 0 to +4 0.0 0 kts B T F o r e / A f t : −1 9 9 to +9. 9 9 kts Port/Stb.: −9. 9 9 to +9. 9 9 kts (with optional ROT) Stern P/S: −9. 0. 0 0 to +4 0. 0 0 kts WT F o r e / A f t : −1
Distance run range
0 to 9 9 9 9 9. 9 9nm
Depth range
B T : 2 to 250m (below hull bottom) depending upon sea bottom conditions WT: 3m or more (below hull bottom)
Speed measuring accuracy
±1% or ±0. 1 kts whichever is greater
Total distance run accuracy
±1% or ±0. 1 nm whichever is greater
Ship speed indication
XX.XX 4-digit indicator (in kts or m/s) (P/S: 3-digit) Analog indication (in kts)
IEC6 1 1 6 2-1 inputs
ROT (Stern P/S speed) **ROT (excl. GPROT) GPS (GPS ship speed) GGA, RMC, RMA, GLL, VTG GYRO (GPS ship speed) HDT, HDG
(NMEA0 1 83) Data outputs
IEC6 1 1 6 2-1: 2 0 0 0 outputs: 5 circuits VBW, VLW, DPT, DBT DC voltage output:
Power supply
2 circuits (for analog indicator)
Opto coupler signal:
8 circuits (2 0 0 pulses/nm)
Relay closure signal:
1 circuit (2 0 0 pulses/nm)
Relay closure signal:
1 circuit (Power fail alarm)
1 0 0/1 1 0/1 1 5/2 2 0/2 3 0VAC ±1 0%、 5 0/6 0Hz, single-phase
Power consumption
3 0 0VA or less
Operating temperature
−1 5 to +5 5℃
Wing Display NWW-61D/T (OPTION)
Remote Display NWW-24 / 25 / 26
Wing Display NWW-61D/T
Main Display NWW-60D/T
(OPTION)
(OPTION)
250V−TTYCS−4 (YARD MAX. 100m)
2ch. Max
Signal Processor NJC-24
R.O.T
250V−TTYCS−1 (YARD MAX. 100m)
(YARD) or (OPTION)
250V−TTYC−4S (YARD MAX. 100m) 250V−TTYC−7S (YARD MAX. 100m) 250V−TTYC−4S (YARD MAX. 100m)
GPS Gyro Echo Sounder Wind
Signal Distributor NQA-3012
250V−TTYC−7S (YARD MAX. 500m) Extension Cable ( JRC MAX. 40m)
Ship's Main Transducer NKF-770
100/110/115/220/230 VAC 50/60Hz 1 PHASE
24 VDC (for Alarm)
0.6/1kV DPYC−1.5 (YARD)
IEC61162-1:2000 .1 IEC61162-1:2000 .2 IEC61162-1:2000 .3 IEC61162-1:2000 .4 IEC61162-1:2000 .5 200 Pulse .1 200 Pulse .2 200 Pulse .3 200 Pulse .4 200 Pulse .5 200 Pulse .6 200 Pulse .7 200 Pulse .8
250V-TTYCS-1 or 250V-DPYCS-1 (YARD MAX.100m)
On line maintenance
0.6/1kV DPYC−1.5 (YARD)
Alarm
CONNECTION DIAGRAM
STANDARD COMPONENTS Description
Model
Main Display
NWW-60DB
Quantity 1
Remarks DB: 2-axis flush mount type (standard) DA: 2-axis wall mount type T B: 3-axis flush mount type T A: 3-axis wall mount type
Signal Distributor
NQA-3012
1
Signal Processor
NJC-24
1
Transducer
NKF-770
1
Spare Parts
7ZXBS0018
1
Instruction Manual
7ZPBS2802
1
IP55 With underwater-mateable connector and max. 40m cable English
OPTIONS Component
Model
Wing Display
NWW-61D
Quantity 2
Remarks D: 2-axis, IP56 T : 3-axis
Remote Display
NWW-24
Remote Display
NWW-25
Remote Display
NWW-26
Distance Counter
NWW-7B
1
Flush-mount type
Gyro Sensor
NJZ-1080
1
ROT
Operator Unit
NWZ-120GA
1
ROT, GA: Wall-mount type GB: Flush-mount type
Rectifier
NBA-3263
1
ROT
Dimmer Unit
NCM-227
1
For NWW-60 Main Display Unit
Dimmer Unit
NCM-329H
1
For NWW-24/25/26 Remote Display Unit
Transducer
NKF-770W
1
Inner demountable type
Transducer
NKF-772
1
Gate valve type
Analog Flush-mount type 2 max.
Analog wall mount type Analog Flush-mount type
DIMENSIONS & WEIGHT Main Display Unit
NWW-60DA
NWW-60DB
NWW-60TA
NWW-60TB
219
220
95
74.8
Weight : 3kg
219
220
95
Weight : 2kg
NJC-24
Signal Processor Unit
320
384
320
384
Unit : mm
74.8
Weight : 3kg
Signal Distributor Unit
Weight : 2kg
NQA-3012 Unit : mm
604
520
553
435
210 357
480
160
Weight : 10kg
Weight : 15kg
Wing Display Unit
NWW-61D(option)
NWW-61T(option) 138.5
225
225
MAX370
Transducer Unit
Unit : mm
292
292
138.5
MAX370
Weight : 5kg
NKF-770
Weight : 5kg
NKF-772(option) Unit : mm
φ155
φ375
355
φ315
532
922
7 φ25
Weight : 250kg
Weight : 120kg φ300
●
Specifications and appearance may be subject to change without notice .
φ232
For further information, contact:
URL
Since 1915
Main Office: Nittochi Nishi-Shinjuku bldg. 10-1, Nishi-Shinjuku 6-chome Shinjuku-ku, Tokyo 160-8328, Japan Telephone: +81-3-3348-4099 Facsimile: +81-3-3348-4139 Overseas Branches : Seattle, Amsterdam Liaison Offices : Taipei, Manila, Jakarta, Singapore, Hanoi, New York, Piraeus ISO9001,ISO14001 Certified
23EM 2003.7
'03.12
CAT.No.Y14-191(No.735-2-5)D