Transcript
JTGB-UF-7609/X Triple Spectral Infrared (IR)) Flame Detectors (Explosion-proof type)
Model JTGB-UF-7609/X Triple spectral infrared (IR)) flame detectors (Explosion-proof type)
JTGB-UF-7609/X
General Description The JTGB-UF-7609/X is a multiple spectral infrared (IR) flame detector which is using three infrared sensors of different wave bands to real-time sampling outside signals. The main sensor responses to the central band of the flame while the reference sensors correspond to the peripheral band. Three sensors that have different response characteristics towards heat sources such as flame, heavy smoke, sunlight and artificial light source provide original foundation of fire behavior judging. Its reliable performance also can distinguish flame at early stage even in complicated environment. It has a preferable immunity of radiation source, for instance, sunlight, artificial light source and other heat elements. The waterproof and explosion-proof design makes JTGB-UF-7609/X suitable for both indoor and outdoor use.
Features · · · · · · · · · · ·
Sample mode: Triple spectral IR Criterion construction: Both time domain and frequency domain Self-checking :Sensitivity self-checking; Electrical performance self-checking Assist-function: Auto-defrosting; Incident record Sensitivity level: Adjustable level 1-3 Detecting angle: Maximum 100° Signal output:RS-485, Standard 4~20mA Relay output:Fire alarm; Fault Explosion-proof rating: ExdIICT6 /DIP A20 TA, T6 Protection rating: IP66 Detection range: Apply to detecting combustion flame caused by carbonaceous materials, not for those caused by certain carbon-free materials, such as hydrogen, sulphur, metal.
Specifications · · · · ·
Operational voltage:
24VDC (Standard) 15~ 35VDC is available Maximum detecting angle:100° Normal standby current: 15mA ~25mA Fire alarm current: 28mA ~40mA Power on time: 24sec.(system self-check)
· · · ·
Heat current:
130mA ~220mA (activating defrosting function ) Operational temperature: -40℃~+75℃ Storage temperature: -40℃~+85℃ Humidity: 0~95%RH,non-condensing
Agency List
Schematic Diagram
Sensitivity Setup JTGB-UF-7609/X has three sensitivity levels which can be adjusted by user. The original set is in level 2. The correspondence of sensitivity and detecting distance is as follows:
Sensitivity Level level 1 level 2 level 3
Detecting Distance 45m 30m 15m
Testing
Testing fuel
33*33*5cm steel basin
Ethanol(2kg), N-heptane (650g), Gasoline(500g), Diesel(500g)
Level 2 sensitivity (original set) should be used in common operational scene; Level 1 sensitivity should be used in location where requires higher detecting intensity; Level 3 sensitivity should be used in special location where has severe interference. Manual setup: move the dial switch of sensitivity levels and setting. Control panel setup: move the dial switch to 00 and then setup by MODBUS instruction. (Refer to communication part of Triple spectral infrared (IR)) flame detectors (Explosion-proof type) Operation and maintainence instruction)
Ordering Information Order type
General description
Unit
JTGB-UF-7609/X Triple spectral infrared (IR)) flame detectors (Explosion-proof type) pcs
System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 630-377-6580 Fx: 630-377-6495 Free Phone: 800-736-7672 Web: www.systemsensor.com
System Sensor China 28 Tuan Jie South Road, Hi-Tech Development Zone Xi'an, 710075, China Ph: +86 29 85387800 Fx: +86 29 88895930 Web: www.systemsensor.com.cn
System Sensor Canada System Sensor Italy Ph: 905-812-0767 Ph: 39 040 949 0111 Fx: 905-812-0771 Fx: 39 040 382 137
System Sensor Far East Ltd System Sensor India Ph: 91 124 2371770-270 Ph: 852 21919003 Fx: 91 124 2373118 Fx: 852 27366580
System Sensor Europe System Sensor Mexico System Sensor Singapore Ph: 44 (0) 1527 406700 Ph: 54 11 4324-1909 Ph: 65 6273 2230 Fx: 44 (0) 1527 406699 Fx: 54 11 4324-5999
Copyright by Xi'an System Sensor Electronics LTD.
System Sensor Australia Ph: 61-3-5428 1142 Fx: 61-3-5428 1172