USER MANUAL VERSION 2.0 October 2011
Metal Panel PC Hardware System
Copyright 2011 All Rights Reserved Manual Version 2.0 Part Number: The information contained in this document is subject to change without notice. We make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. We shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without the prior written consent of the manufacturer.
TRADEMARK Intel®, Pentium® and MMX are registered trademarks of Intel® Corporation. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. Other trademarks mentioned herein are the property of their respective owners.
Safety IMPORTANT SAFETY INSTRUCTIONS
111 To disconnect the machine from the electrical power supply, turn off the power switch and remove the power cord plug from the wall socket. The wall socket must be easily accessible and in close proximity to the machine. 222 Read these instructions carefully. Save these instructions for future reference. 333 Follow all warnings and instructions marked on the product. 444 Do not use this product near water. 555 Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious damage to the product. 666 Slots and openings in the cabinet and the back or bottom are provided for ventilation to ensure reliable operation of the product and to protect it from overheating. These openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or heat register or in a built-in installation unless proper ventilation is provided. 777 This product should be operated from the type of power indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company. 888 Do not allow anything to rest on the power cord. Do not locate this product where persons will walk on the cord. 999 Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product.
ii
CE MARK
This device complies with the requirements of the EEC directive 2004/108/EC with regard to “Electromagnetic compatibility” and 2006/95/EC “Low Voltage Directive”.
FCC
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.
CAUTION ON LITHIUM BATTERIES There is a danger of explosion if the battery is replaced incorrectly. Replace only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s instructions.
Battery Caution
Risk of explosion if battery is replaced by an incorrectly type. Dispose of used battery according to the local disposal instructions.
Safety Caution
Note: To comply with IEC60950-1 Clause 2.5 (limited power sources, L.P.S) related legislation, peripherals shall be 4.7.3.2 “Materials for fire enclosure” compliant. 4.7.3.2 Materials for fi re enclosures For MOVABLE EQUIPMENT having a total mass not exceeding 18kg.the material of a FIRE ENCLOSURE, in the thinnest significant wall thickness used, shall be of V-1 CLASS MATERIAL or shall pass the test of Clause A.2. For MOVABLE EQUIPMENT having a total mass exceeding 18kg and for all STATIONARY EQUIPMENT, the material of a FIRE ENCLOSURE, in the thinnest significant wall thickness used, shall be of 5VB CLASS MATERIAL or shall pass the test of Clause A.1
iii
LEGISLATION AND WEEE SYMBOL 2002/96/EC Waste Electrical and Electronic Equipment Directive on the treatment, collection, recycling and disposal of electric and electronic devices and their components.
The crossed dust bin symbol on the device means that it should not be disposed of with other household wastes at the end of its working life. Instead, the device should be taken to the waste collection centers for activation of the treatment, collection, recycling and disposal procedure. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.
iv
Revision History Changes to the original user manual are listed below:
Revision Description 1.0
1.1
•• •• •• •• ••
Initial release Cover page. photo update I/O view photo update chapter4. reorganized and photo updated chapter5. CPU support, Brightness, Touch Screen Type, Environment, Dimension, Mounting info updated •• 2nd VGA added •• Chapter8. photo updated •• •• •• •• ••
1.3
1.4 1.5 2.0
•• ••
B78 MB upgraded from v1.1 to B78 V2.2 B98 MB V1.0 added Drivers upgraded 2nd Fan added for B98 Specification changed (B98 MB added, HDD changed from PATA to SATA) Driver CD photo updated to v1.9 I/O changed from Line-in, Line-out to MIC-In, Line-Out Jumper Settings upgraded Photo of rear cover of system changed
•• •• •• •• •• ••
B68 motherboard added Jumper setting updated Jumper setting updated Safety message updated B78 motherboard removed C48 motherboard added
•• ••
Date
May 2007
October 2007
February 2009
February 2010 October 2010 October 2011
v
Table of Contents 1. Packing List............................... 1 1-1. Standard Accessories...............................................1 1-2. Optional Accessories................................................1
2. System View.............................. 2 2-1. Front View................................................................2 2-2. Rear View.................................................................2 2-3. I/O Ports View...........................................................3 2-4. Dimensions...............................................................4
3. System Assembly..................... 6 3-1. HDD Replacement....................................................6 3-2. RAM Replacement...................................................7 3-3. Power Adapter Replacement....................................8
4. Peripheral Installation.............. 9
4-1. MSR Installation.......................................................9 4-2. Wall Mount Kit Assembly..........................................9 4-3. Desktop Stand Assembly.........................................10 4-4. Wireless LAN Installation......................................... 11 4-5. CF Card Module Installation....................................12 4-5-1 For system with vent..............................................12 4-5-2. For ventless system..............................................13 4-6. Cash Drawer Installation.........................................14
vi
5. Specification............................ 16 5-1. B98 motherboard Specification...............................16 5-2. B68 motherboard Specification...............................18 5-3. C48 motherboard Specification...............................19 5-4. B98 Motherboard.....................................................20 5-4-1. Motherboard Layout................................................. 20 5-4-2. Connectors & Functions........................................... 21 5-4-3. Jumper Setting......................................................... 22
5-5. B68 Motherboard.....................................................26 5-5-1. Motherboard Layout................................................. 26 5-5-2. Connectors & Functions........................................... 27 5-5-3. Jumper Setting......................................................... 29
5-6. C48 Motherboard.....................................................33 5-6-1. Motherboard Layout................................................. 33 5-6-2. Connectors & Functions........................................... 35 5-6-3. Jumper & BIOS/Utility Setting.................................. 36
Appendix: Drivers Installation..... 43
vii
The page is intentionally left blank. viii
1. Packing List 11111 Standard Accessories a.
c.
b.
d. e.
aaa bbb ccc ddd eee
System Driver bank Power adapter (90W) Power cord RJ45-DB9 cable (x2)
11111 Optional Accessories a.
d.
b.
e. CF Card
c. aaa bbb ccc ddd eee
AN
WL
CF bride board
CF bracket
Card
Desktop Stand Kit Module Wall-mount Kit Wireless LAN Card + External Antenna MSR Module CF Card Module 1
2. System View 22222 Front View 1
22222 Rear View
3
2 5 4
Item No. 1 2 3 4 5 6 7 2
6
Description Touch screen External antenna installation hole (Optional) Speaker holes MSR module installation place (Optional) Hard drive disk door VESA mounting screw holes Ventilation holes
7
22222 I/O Ports View 12" System
j
a
b
c
d
e f g h
c
d
e f g h
i
15", 17", 19" System
a
Item No. a b c d e f g h i j
b
i
j
Description Power Switch Parallel USB x 4 COM 1, 2, 3, 4 (from right to left) Line-out MIC-in Cash Drawer (support 12V/24V cash drawer) LAN DC-In VGA Port
3
22222 Dimensions 12" System 40
56
115
100
100
189 265
83
38
331 251
Unit: mm
15" System 143
100
104
61
100
37
37
234 307
386 312
uint: mm
4
17” System
155
61
34
100
345 274
100
122
35
411 342
unit: mm
19” System 175
61
100
100
137
35
35
304 374
449 379
unit: mm
5
3. System Assembly 33333 HDD Replacement
111 Turn to the rear side of the system. 222 Unscrew the screw (x1) securing the HDD door and the rear cover of the system.
333 Disconnect the SATA cable from the drive.
6
33333 RAM Replacement Please open the rear cover first then remove and replace the RAM module. You can refer to the motherboard layout to find the memory compartment. (See Chapter 6-1, Chapter 6-2 or Chapter 6-3 for different motherboard)
Opening the Rear Cover 111 Remove the HDD (see Chapter 3-1) and unscrew the screws (x15) on the rear cover to access the motherboard.
Removing a RAM Module 222 Use both fingers to pull the ejector clips out of the sides of the module. 333 Slide the memory module out of the memory slot.
Installing a RAM Module 444 Slide the memory module into the memory slot and press down until the ejector clips click in place.
7
3-3.
Power Adapter Replacement If your system is equipped with a stand, please replace the power adapter by following the steps below. 1. Disconnect the power cable from the I/O panel. 2. Route the power cable through the cable management hole on the stand as the direction of the arrow shows.
3. Disconnect the power cord from the power adapter which is fixed in the power adapter bracket preinstalled in the stand.
4. Loosen the screws (x2) to remove the power adapter bracket. 5. Gently pull the power adapter out of the cable management hole of the stand. 6. Replace the power adapter by reversing the procedure of above steps.
8
4. Peripheral Installation 44444 MSR Installation 111 Turn the system to the rear side. 222 Attach the MSR module into the right position of the system and fasten the screws (x2). 333 Connect the MSR cable to the COM-RJ45 convertible connector on the I/O panel. Note: Please set up the power setting for COM3 or COM4 with 5V, see Chapter 6 - Jumper Setting (page 22 for B78 motherboard, page 28 for B98 motherboard and page 34 for B68 motherboard)
44444 Wall Mount Kit Assembly 111 Fix the wall-mount bracket onto the wall. 222 Place the VESA bracket onto the VESA mounting holes on the system and fasten the screws (x4). 333 Align the VESA bracket with the system into the wall-mount brakcet and make sure they are well fixed.
VESA bracket Wall-mount bracket
9
44444 Desktop Stand Assembly Accessories items
a. VESA bracket b. Stand bracket c. Stand d. Hinge cover x2 e. Screws for both sides of stand x6 f. Screws for VESA bracket x 4 111 Align the guide slot of the stand bracket into the hinge shaft of the stand and fix them with the screws (x6). 222 Align the hinge cover (x2) into the right position of the stand bracket and fix it until you hear a click sound.
333 Align the VESA bracket onto the VESA mounting holes of the system and fasten the screws (x4).
444 Align the VESA bracket with the system to the stand bracket and the stand, make sure they are well secured to each other.
10
a
b
c
d
e
f
44444 Wireless LAN Installation
111 Disconnect the HDD cable from the system first (see Chapter 3-1).
To external antenna
222 Unscrew the screws (x15) to remove the rear cover. 333 Assemble the antenna cable and bracket by fasten the nut, washer and the coaxial cable as picture instructs. 444 Insert the WLAN card to the WLAN socket on the motherboard and press it downward until the ejector clips lock it in place. 555 Connect the antenna cable to the “main connector” on the WLAN card. 666 Cover the rear cover by reversing the step 2. 777 The pre-drilled hole for the external antenna installation is on the rear cover of the system. Rotate the external antenna clockwise to fix it to the connector of the internal antenna cable.
11
44444 CF Card Module Installation 4-5-1 For system with vent 111 Turn over the system to access the HDD door. 222 Unfasten the screw (x1) to remove the HDD door.
CF CARD
333 Assemble the CF bridge board onto the HDD bay with the screws (x3).
444 Replace the CF card by sliding it into or outward from the slot of CF bridge board. 555 Reverse the step 1 to cover the HDD door. CF CARD
12
4-5-2. For ventless system 111 Turn over the system. 222 Open the rear cover by unfastening the screws (x15) to access the CF installaing place inside of the enclosure. 333 Place the CF bracket onto the bosses (x4) fixed on the LCD chassis with the screws (x4). 444 Assemble the CF bridge board and the CF bracket with the screws (x3) provided. 555 Slide the CF card into the slot of CF bridge board. 666 Reverse the steps by step 1 to cover the rear cover.
a
b
13
44444 Cash Drawer Installation You can install a cash drawer through the cash drawer port. Please verify the pin assignment before installation.
Cash Drawer Pin Assignment
6
Pin 1 2 3 4 5 6
1
Signal GND DOUT bit0 DIN bit0 12V / 24V DOUT bit1 GND
Cash Drawer Controller Register
The Cash Drawer Controller use one I/O addresses to control the Cash Drawer. Register Location: 48Ch Attribute: Read / Write Size: 8bit BIT BIT7 Attribute Reserved
BIT6 Read
BIT5 BIT4 Reserved
BIT3
BIT2 Write
BIT1 BIT0 Reserved
7 6 5 4 3 2 1 0 X X X X X Reserved Cash Drawer “DOUT bit0” pin output control Cash Drawer “DOUT bit1” pin output control Reserved Cash Drawer “DIN bit0” pin input status Reserved
14
Bit 7: Reserved Bit 6: Cash Drawer “DIN bit0” pin input status. = 1: the Cash Drawer closed or no Cash Drawer = 0: the Cash Drawer opened Bit 5: Reserved Bit 4: Reserved Bit 3: Cash Drawer “DOUT bit1” pin output control. = 1: Opening the Cash Drawer = 0: Allow close the Cash Drawer Bit 2: Cash Drawer “DOUT bit0” pin output control. = 1: Opening the Cash Drawer = 0: Allow close the Cash Drawer Bit 1: Reserved Bit 0: Reserved Note: Please follow the Cash Drawer control signal design to control the Cash Drawer.
Cash Drawer Control Command Example Use Debug.EXE program under DOS or Windows98 Command Cash Drawer O 48C 04 Opening O 48C 00 Allow to close ►► Set the I/O address 48Ch bit2 =1 for opening Cash Drawer by “DOUT bit0” pin control. ►► Set the I/O address 48Ch bit2 = 0 for allow close Cash Drawer.
Command Cash Drawer I 48C Check status ►► The I/O address 48Ch bit6 =1 mean the Cash Drawer is opened or not exist. ►► The I/O address 48Ch bit6 =0 mean the Cash Drawer is closed.
15
5. Specification 55555
B98 motherboard Specification
Motherboard
CPU Supports Chipset System Memory Graphic Memory
LCD / Touch Panel Model Name LCD Size Brightness Maximal Resolution Touch Screen Type
Storage
B98
Celeron M 1.86GHz;Core Due 2.0GHz;Core 2 Due 1.66GHz/2.16GHz Intel 945GME+ ICH7M FSB 533MHz 2 x DDRII SO-DIMM slot, up to 4 GB Share system memory max 224MB K792 12" TFT LCD 370nits 800 x 600 Resistive touch
K795 K797 K799 15" TFT LCD 17" TFT LCD 19" TFT LCD 350nits 300nits 300nits 1024 x 768 1280 x 1024 Resistive type / SAW Touch / IR Touch
HDD Flash Memory
2.5" Slim HDD bay, SATA HDD 1 Optional Compact Flash memory (without HDD)
mini-PCI Slot
x1 (support 802.11 a/b/g WLAN card )
Expansion
External I / O Ports USB 2.0
Serial / COM Parallel LAN (10 / 100/1000) Cash Drawer DC Jack Audio Jack 2nd VGA
Internal Interface USB 2.0 Audio Speaker
Power Power Adapter Environment
EMC & Safety Operating Temperature Storage Temperature Operating Humidity Storage Humidity Dust & Water Proof
16
4 x USB Type A RJ-45 (COM1 standard RS-232; COM2 RS-232 / 422 / 485 selectable by jumper; COM3 & COM4 pin 9 with 5V or 12V power by jumper) 1 x D-sub 25F 1 x RJ-45 1 x RJ-11 (12V or 24V) 1 x Latch Type 1 x Mic-in, 1 x Line-out 1 x DB 15F 2 1 x 3W Speaker
2 x 3W Speakers DC 19V / 90W FCC Class A, CE, LVD 0°C ~ 40°C (32°F ~ 104°F) -20° ~ 60°C (-4°F ~ 140°F) 5% - 95% RH non-condensing 5% - 95% RH non-condensing NEMA 4 / IP 65 (front)
Motherboard Dimension (W x D x Weight (N.W.) Mounting OS Support
B98
331 x 265 x 55 mm 386 x 308 x 60 mm 411 x 345 x 60 mm 449 x 374 x 60 mm H) 13" x 10.5" x 2.2" 15.2"x 12.1"x 2.4" 16.2" x 13.6" x 2.4" 17.7" x 14.7" x 2.4" 4.7kgs / 10.4 lbs 5.8 kgs / 12.8 lbs 7.6 kgs / 16.7 lbs 9 kgs / 19.8 lbs 100mm x 100mm Standard VESA / Panel Mount Windows® XP Professional, Windows Embedded POSReady 2009, Windows XP Embedded, Windows XP Professional for Embedded, Windows 7, Linux
17
55555
B68 motherboard Specification
Motherboard
CPU Supports Chipset System Memory Graphic Memory
LCD / Touch Panel Model Name LCD Size Brightness Maximal Resolution Touch Screen Type
Storage
B68
Intel Atom N270 processor 1.6GHz L2 512K Intel 945GSE Express + ICH7M FSB 533MHz 2 x DDRII SO-DIMM slot, up to 2GB Share system memory max 224MB K792 12" TFT LCD 370nits 800 x 600 Resistive touch
K795 K797 K799 15" TFT LCD 17" TFT LCD 19" TFT LCD 350nits 300nits 300nits 1024 x 768 1280 x 1024 Resistive type / SAW touch / IR Touch
HDD Flash Memory
2.5" Slim HDD bay, SATA HDD 1 Optional Compact Flash memory (without HDD)
mini-PCI-E Slot
x1 (support 802.11 a/b/g WLAN card)
Expansion
External I / O Ports USB 2.0
Serial / COM Parallel LAN (10 / 100/1000) Cash Drawer DC Jack Audio Jack 2nd VGA
Internal Interface
4 x USB Type A RJ-45 (COM1 standard RS-232; COM2 RS-232 / 422 / 485 selectable by jumper; COM3 & COM4 pin 9 with 5V or 12V power by jumper) 1 x D-sub 25F 1 x RJ-45 1 x RJ-11 (12V or 24V) 1 x Latch Type 1 x Mic-in, 1 x Line-out 1 x DB 15F
USB 2.0
Audio
Speaker
Power
Power Adapter
Environment
EMC & Safety Operating Temperature Storage Temperature Operating Humidity Storage Humidity Dust & Water Proof
Dimension (W x D x Weight (N.W.) Mounting OS Support
18
2 1 x 3W Speaker
2 x 3W Speakers DC 19V / 90W
FCC Class A, CE, LVD 0°C ~ 40°C (32°F ~ 104°F) -20° ~ 60°C (-4°F ~ 140°F) 5% - 95% RH non-condensing 5% - 95% RH non-condensing NEMA 4 / IP 65 (front) 331 x 265 x 55 mm 386 x 308 x 60 mm 411 x 345 x 60 mm 449 x 374 x 60 mm H) 13" x 10.5" x 2.2" 15.2"x 12.1"x 2.4" 16.2" x 13.6" x 2.4" 17.7" x 14.7"x 2.4" 4.7kgs / 10.4 lbs 5.8 kgs / 12.8 lbs 7.6 kgs / 16.7 lbs 9 kgs / 19.8 lbs 100mm x 100mm Standard VESA / Panel Mount Windows® XP Professional, Windows Embedded POSReady 2009, Windows XP Embedded, Windows XP Professional for Embedded, WinCE, Windows 7, Linux
55555
C48 motherboard Specification
Motherboard
C48
CPU Supports Chipset System Memory Graphic Memory
LCD / Touch Panel Model Name LCD Size Brightness Maximal Resolution Touch Screen Type
Storage
Intel® Pineview Dual Core D525 1.8G Intel® Pineview CPU processor + ICH8M 2 x DDR3 SO-DIMM slot, up to 4GB Share system memory max 256MB K792 12" TFT LCD 370nits 800 x 600 Resistive touch
K795 K797 K799 15" TFT LCD 17" TFT LCD 19" TFT LCD 350nits 300nits 300nits 1024 x 768 1280 x 1024 Resistive type / SAW touch / IR Touch
HDD Flash Memory
2.5" Slim HDD bay, SATA HDD 1 Optional Compact Flash memory (without HDD)
mini-PCI-E Slot
x1 (support 802.11 a/b/g WLAN card)
Expansion
External I / O Ports USB 2.0
Serial / COM Parallel LAN (10 / 100/1000) Cash Drawer DC Jack Audio Jack 2nd VGA
Internal Interface
4 x USB Type A RJ-45 (COM1 standard RS-232; COM2 RS-232 / 422 / 485 selectable by jumper; COM3 & COM4 pin 9 with 5V or 12V power by jumper) 1 x D-sub 25F 1 x RJ-45 1 x RJ-11 (12V or 24V) 1 x Latch Type 1 x Mic-in, 1 x Line-out 1 x DB 15F
USB 2.0
Audio
Speaker
Power
Power Adapter
Environment
EMC & Safety Operating Temperature Storage Temperature Operating Humidity Storage Humidity Dust & Water Proof
Dimension (W x D x Weight (N.W.) Mounting OS Support
2 1 x 3W Speaker
2 x 3W Speakers DC 19V / 90W
FCC Class A, CE, LVD 0°C ~ 40°C (32°F ~ 104°F) -20° ~ 60°C (-4°F ~ 140°F) 5% - 95% RH non-condensing 5% - 95% RH non-condensing NEMA 4 / IP 65 (front) 331 x 265 x 55 mm 386 x 308 x 60 mm 411 x 345 x 60 mm 449 x 374 x 60 mm H) 13" x 10.5" x 2.2" 15.2"x 12.1"x 2.4" 16.2" x 13.6" x 2.4" 17.7" x 14.7"x 2.4" 4.7kgs / 10.4 lbs 5.8 kgs / 12.8 lbs 7.6 kgs / 16.7 lbs 9 kgs / 19.8 lbs 100mm x 100mm Standard VESA / Panel Mount Windows® XP Professional, Windows Embedded POSReady 2009, Windows XP Embedded, Windows XP Professional for Embedded, WinCE, Windows 7, Linux
19
5-4.
B98 Motherboard 5-4-1. Motherboard Layout
JP3 JP12 JP11
JP4 JP6 JP5
JP7 JP8
Version: B98 v1.1 20
5-4-2. Connectors & Functions Connector BAT3 CN3 CN4 CN5 CN8 CN9 CN11 CN12 CN13 CN14 CN15 CN16 CN18 CN19 CN20 CN21 CN22 DDR2_A1 DDR2_B1 FAN_CPU3 FAN_SYS3 MINI_PCIE3 PCI3 PRN3 PWR3 RJ11_3 RJ45_3 RJ45_4 SATA1 SATA2 SKT1 SW3 USB3 USB4 JP3 JP4/JP6 JP5 JP7 JP8 JP9 JP13 JP11
Purpose CMOS Battery Base (Use CR2023) Audio Line Out MIC In Internal Power On Switch Connector Speaker & MIC Connector Internal LAN LED CD-IN / Line-In Connector LCD Interface Connector IrDA Connector Inverter Connector COM5 for Touch Power Connector For HDD USB5 Card Reader Connector Reserved Internal Input Power Connector Hardware Reset DDR2 SO-DIMM DDR2 SO-DIMM CPU FAN Connector System FAN Connector Mini PCI-E Socket Mini PCI Socket Parallel Port +19V Power Adaptor Cash Drawer Connector LAN (On Board) COM1, COM2, COM3, COM4 SATA Connector SATA Connector SPI ROM Power On Button USB1, USB2 USB3, USB4 Power Option for Cash Drawer COM2 RS232/485/422 Setting Power Option for COM3/COM4 CMOS Operation Mode LCD ID Setting VGA Port VGA Power / DDC AT/ATX Setting
21
5-4-3. Jumper Setting
COM2 RS232/485/422 Setting Function
JP6
JP4
▲RS232
1 3 5 7 9 11 2 4 6 8 10 12
1 3 5 7 9 2 4 6 8 10
RS485
1 3 5 7 9 11 2 4 6 8 10 12
1 3 5 7 9 2 4 6 8 10
RS422
1 3 5 7 9 11 2 4 6 8 10 12
1 3 5 7 9 2 4 6 8 10
COM3 & COM4 Power Setting Function
COM3 Pin10
COM4 Pin10
JP5 ▲RI
1 3 5 7 9 11 2 4 6 8 10 12
+5V
1 3 5 7 9 11 2 4 6 8 10 12
+12V
1 3 5 7 9 11 2 4 6 8 10 12
▲RI
1 3 5 7 9 11 2 4 6 8 10 12
+5V
1 3 5 7 9 11 2 4 6 8 10 12
+12V
1 3 5 7 9 11 2 4 6 8 10 12
▲ = Manufacturer Default Setting Note: Please see pin definition of COM3 and COM4 connector as next page.
22
RJ45-DB9F serial cable 6
1
PIN1
P2 9
P1 PIN10
5
Pin Definition RJ45 pin 2 4 6 8 9 3 5 7 10 1
RS_232 DCD# RX# TX# DTR# GND DSR# RTS# CTS# RI# ---
RS_485 RS485_TXRXRS485_TXRX+ NC NC GND NC NC NC NC NC
RS_422 RS422_TXRS422_TX+ RS422_RX+ RS422_RXGND NC NC NC NC NC
DB9 pin 1 2 3 4 5 6 7 8 9 ---
23
Cash Drawer Power Setting Function +12V ▲+19V (for 24V Cash Drawer)
JP3 1 3 5 2 4 6 1 3 5 2 4 6
Power Mode Setting Function
JP11
▲ATX Power
1 2
AT Power
1 2
CMOS Operation Mode Function
JP7
▲CMOS Normal
1 2
CMOS Reset
1 2
▲ = Manufacturer Default Setting
24
LCD ID Setting
LVDS Output Channel Interface
Panel#
Resolution
1
1366 x 768
24
Single
LVDS Panel
1 3 5 7 2 4 6 8
2
1440 x 900
24
Dual
LVDS Panel
1 3 5 7 2 4 6 8
4
1920 x 1080
24
Dual
LVDS Panel
1 3 5 7 2 4 6 8
5
1024 x 768
24
Single
LVDS Panel
1 3 5 7 2 4 6 8
6
1280 x 1024
24
Dual
LVDS Panel
1 3 5 7 2 4 6 8
7
800 x 600
24
Single
LVDS Panel
1 3 5 7 2 4 6 8
9
1024 x 768
18
Single
LVDS Panel
1 3 5 7 2 4 6 8
11
800 x 600
18
Single
LVDS Panel
1 3 5 7 2 4 6 8
12
800 x 600
18
Single
LVDS Panel
1 3 5 7 2 4 6 8
CRT
1 3 5 7 2 4 6 8
Bits
JP8
Remark: Panel ID#12 is specialized for Sharp 12.1" LQ121S1LG41 / LQ121S1LG42 panel .
1 2
Jumper open
1 2
Jumper short
25
SW1
26 U12
CPU1
SATA1
CN4
CN21/JP2
JP1
JP6
CN5
CN6
JP4
JP3 JP5
RJ45-1
JP6 JP5 JP3
CN2
FAN_CPU1
USB2
CN8 SATA2
CN7
CN10
JP7
BAT1
CN9
JP8
CN13
CN14 CN15
CN12
CN3
U37
SKT1
CN11
JP8
DRR2_A1
CN22
USB1
JP9
CN17
JP10 CN16
CN20
CN19
BZ1
MINI_PCIE1
RJ45-2
CN18
JP11
RJ11-1
JP11
CN23
CN1
PRN1
JP12
PWR1
55555 B68 Motherboard 5-5-1. Motherboard Layout
JP9
JP7
JP4
Version: B68 v1.0
5-5-2. Connectors & Functions Connector BAT1 CN1 CN2 CN3 CN4 CN5 CN6 CN7 CN8 CN9 CN10 CN11 CN12 CN13 CN14 CN15 CN17 CN18 CN19 CN20 CN21 CN22 CN23 DDR2_A1 DDR2_A2 PRN1 PWR1 RJ11_1 RJ45_1 RJ45_2 SATA1 SATA2
Purpose CMOS Battery Base ( Use CR2023) Power On Button Touch Sensor Power LED SATA1 HDD Power Connector SATA2 HDD Power Connector LCD Interface Connector IrDA Connector For External Touch Connector Inverter Connector Card Reader Connector Line Out LED Power MIC In Speaker & MIC CONN CD-IN CONN LAN LED USB5 DC-Jack PS2 KEYBOARD For Bedside Terminal LPT Interface for Touch For LPT Touch Reset DDR2 SO-DIMM1 DDR2 SO-DIMM2 Parallel Port +19V Power Adaptor Cash Drawer Connector COM1, COM2, COM3, COM4 LAN SATA Connector SATA Connector
27
Connector SKT1 USB1 USB2 SW1 JP1 JP2 JP3 JP4 JP5 JP6 JP7 JP8 JP9 JP11 JP12
28
Purpose SPI ROM USB1, USB2 USB3, USB4 Power On Bottom CRT Connector CRT Power/I2C Connector Power Option for COM3/COM4 2nd Display Power COM2 Connector COM2(RS232/422/485) Setting LCD ID Setting RTC Reset AT Function Cash Drawer Power Setting (+12V,+24V) Hardware Reset
5-5-3. Jumper Setting
COM2 RS232/485/422 Setting Function
JP6
JP5
▲RS232
1 3 5 7 9 2 4 6 8 10
1 3 5 7 9 11 2 4 6 8 10 12
RS485
1 3 5 7 9 2 4 6 8 10
1 3 5 7 9 11 2 4 6 8 10 12
RS422
1 3 5 7 9 2 4 6 8 10
1 3 5 7 9 11 2 4 6 8 10 12
COM3 & COM4 Power Setting Function
COM3 Pin10
COM4 Pin10
JP3
▲RI
1 3 5 7 9 11 2 4 6 8 10 12
+5V
1 3 5 7 9 11 2 4 6 8 10 12
+12V
1 3 5 7 9 11 2 4 6 8 10 12
▲RI
1 3 5 7 9 11 2 4 6 8 10 12
+5V
1 3 5 7 9 11 2 4 6 8 10 12
+12V
1 3 5 7 9 11 2 4 6 8 10 12
▲ = Manufacturer Default Setting
Note: Please see pin definition of COM3 and COM4 connector as next page.
29
RJ45-DB9F serial cable 6
1
PIN1
P2 9
P1 PIN10
5
Pin Definition RJ45 pin 2 4 6 8 9 3 5 7 10 1
30
RS_232 DCD# RX# TX# DTR# GND DSR# RTS# CTS# RI# ---
RS_485 RS485_TXRXRS485_TXRX+ NC NC GND NC NC NC NC NC
RS_422 RS422_TXRS422_TX+ RS422_RX+ RS422_RXGND NC NC NC NC NC
DB9 pin 1 2 3 4 5 6 7 8 9 ---
Cash Drawer Power Setting Function +12V ▲+19V (for 24V Cash Drawer)
Power Mode Setting
JP11 1 3 2 4 1 3 2 4
Function
JP9
▲ATX Power
1 2
AT Power
CMOS Operation Mode
1 2
Function
JP8
▲CMOS Normal
1 2
CMOS Reset
1 2
VGA Power Setting Function
JP4
▲No Power
1 2
+12V
1 2
▲ = Manufacturer Default Setting 31
LCD ID Setting
LVDS Output Channel Interface
Panel#
Resolution
1
1366 x 768
24
Single
LVDS Panel
1 3 5 7 2 4 6 8
2
1440 x 900
24
Dual
LVDS Panel
1 3 5 7 2 4 6 8
4
1920 x 1080
24
Dual
LVDS Panel
1 3 5 7 2 4 6 8
5
1024 x 768
24
Single
LVDS Panel
1 3 5 7 2 4 6 8
6
1280 x 1024
24
Dual
LVDS Panel
1 3 5 7 2 4 6 8
7
800 x 600
24
Single
LVDS Panel
1 3 5 7 2 4 6 8
9
1024 x 768
18
Single
LVDS Panel
1 3 5 7 2 4 6 8
11
800 x 600
18
Single
LVDS Panel
1 3 5 7 2 4 6 8
12
800 x 600
18
Single
LVDS Panel
1 3 5 7 2 4 6 8
CRT
1 3 5 7 2 4 6 8
Bits
JP7
Remark: Panel ID#12 is specialized for Sharp 12.1" LQ121S1LG41 / LQ121S1LG42 panel.
1 2
32
Jumper open
1 2
Jumper short
55555 C48 Motherboard
15
2
18
PWR1
16
17
5-6-1. Motherboard Layout
MINI_PCIE
CN24
JP12
JP12
CN23
RJ45_2
CN22
CN17
CN18
SKT1
CN16
CN15
CN20 CN19
CN13
AJ
JP8
JP9
11
CN21
AG AE AC AA AH AF AD AB Y W V U T R P N M L K J H G F E D C B A
27 25 23 21 19 17 15 13 11 9 8 7 5 3 1 18 16 14 12 6 4 2 28 26 24 22 20 10
RJ11_1
CN14
JP10
JP10
JP19
29
JP19
CN27
JP8 JP6 JP18
RJ45_1
CN8
CN31
SATA2
JP20 JP6
JP20
JP5
CN7
JP4 JP4
JP14
CN5
JP18 JP5
JP14
JP9
CN11
JP3
JP3
CN26 SATA1
USB2
JP1
CN29
USB1
JP1
A B DC E F G H J K L M N PR T VU W YAA AB AC AD AE AF AG AH AJ AK AL
2 4 6 8 10 12 141618 20 22 24 26 28 30 1 3 5 7 9 111315 171921 23 25 27 29 31
PRN1
FAN_CPU1
DDR3_A1
CN4 CN1
SW1
JP21 CN3
JP21
CN25 CN28
C48 V2.1 TOP LAYER
33
DDR3_A2
C48 V2.1 BOTTOM LAYER
34
5-6-2. Connectors & Functions Connector CN1 CN3 CN4 CN5/8 CN11 CN13 CN14 CN15 CN16 CN18 CN20/JP10 CN22 CN23 CN26 CN27 CN29 DDR3_A1 DDR3_A2
Purpose Power Button Connector Printer Port Reset Printer Port HDD Power COM5 For Touch Card Reader Connector Line out HDD LED Speaker & MIC MIC IN System Indicator USB Port PS2 KEYBOARD LVDS Inverter Connector System Fan DDR3 SO-DIMM1 DDR3 SO-DIMM2
PRN1 PWR1 RJ11_1 RJ45_1 RJ45_2 SATA1 SATA2 USB1 USB2 SW1 JP1 JP3/6 JP4/5 JP8 JP9 JP12 JP14 JP18 JP19
Parallel Port +19V DC Jack Cash Drawer Connector COM1, COM2, COM3, COM4 LAN SATA Connector SATA Connector USB1, USB2 USB3, USB4 Power Button CMOS Operation Mode VGA Port COM2 RS232/485/422 Setting LCD ID Setting Power Mode Setting System Reset Inverter Selection COM3/4 Power Setting Cash Drawer Power Setting
35
5-6-3. Jumper & BIOS/Utility Setting COM2 RS232/485/422 Setting Function JP5
JP4
▲RS232
1 3 5 7 9 2 4 6 8 10
1 3 5 7 9 11 2 4 6 8 10 12
RS485
1 3 5 7 9 2 4 6 8 10
1 3 5 7 9 11 2 4 6 8 10 12
RS422
1 3 5 7 9 2 4 6 8 10
1 3 5 7 9 11 2 4 6 8 10 12
COM3 & COM4 Power Setting COM3 and COM4 can be set to provide power to your serial device. The voltage can be set to +5V or 12V by setting jumper JP18 on the motherboard. When enabled, the power is available on pin 10 of the RJ45 serial connector.. If you use the serial RJ45 to DB9 adapter cable, the power is on pin 9 of the DB9 connector. By default, the power option is disabled in the BIOS.
BIOS/Utility setup 111 Press key to enter BIOS SETUP UTILITY when system boot up. 222 Find tab "Advanced". 333 Select "Power Configuration COM/VGA Ports" and press to go to sub screen.
36
4. To switch on the power, select "Power". Please save the change before exiting BIOS so as to go for physical jumper adjustment.
COM3/COM4 Jumper setup Function
JP18
▲+5V
1 3 5 7 2 4 6 8
+12V
1 3 5 7 2 4 6 8
+5V
1 3 5 7 2 4 6 8
COM3
COM4 ▲+12V
1 3 5 7 2 4 6 8
Function
JP1
▲CMOS Normal
1 2
CMOS Reset
1 2
▲ = Manufacturer Default Setting
37
Cash Drawer Power Setting Function
JP19
+19V
1 3 2 4
▲+12V
1 3 2 4
Power Mode Setting Function ▲ATX Power AT Power
JP9 1 2 1 2
System Indicator Function
JP10
▲Disable
1 3 5 7 2 4 6 8
Enable
1 3 5 7 2 4 6 8
Inverter Selection Function ▲ CCFL
1 3 5 2 4 6
LED
1 3 5 2 4 6
▲ = Manufacturer Default Setting
38
JP14
CMOS Operation Mode CMOS Reset
To clear the CMOS, 1. Remove the power cable from the system. 2. Open the system, and set the ‘CMOS Operation jumper’ from ‘CMOS Normal’ to ‘CMOS Reset’. (refer to the jumper shown below) 3. Connect the power cable to the system, and power on the system: in ATX mode: press the power button and it will fail power on in AT mode: turn on system power 4. Remove the power cable from the system. 5. Return the "CMOS Operation mode" jumper setting from "CMOS Reset" to "CMOS normal". 6. Connect the power cable and power on the system. Function
JP1
▲CMOS Normal
1 2
CMOS Reset
1 2
▲ = Manufacturer Default Setting
39
LCD ID Setting Several configurations are applied to different sizes of panel. Please refer to the followings to complete relevant settings. Resolution
Bits
LVDS Channel
Output Interface
JP8
800 x 600
24
Single
1 3 5 7 2 4 6 8
*1024 x 768
24
Single
1 3 5 7 2 4 6 8
1366 x 768
24
Single
1 3 5 7 2 4 6 8
800 x 600
18
Single
800 x 600
18
Single
1 3 5 7 2 4 6 8
1024 x 768
18
Single
1 3 5 7 2 4 6 8
1280 x 1024
24
Dual
1st: LCD Panel 2nd: VGA port
1st: VGA port
1 3 5 7 2 4 6 8
1 3 5 7 2 4 6 8
*remark: specialized for Sharp 12.1” LQ121S1LG41/LQ121S1LG42 panel. 1 2
Jumper open
1 2
Jumper short
2nd VGA Power Setting VGA port power must be on through BIOS/Utility for default is “No Power“.
BIOS/Utility setup 111 Press key to enter BIOS SETUP UTILITY when system boot up. 222 Find tab "Advanced". 333 Select "Power Configuration COM/VGA Ports" and press to go to sub screen.
40
4. To switch on the power, select "+12V". Please save the change before exiting BIOS to avoid data lost.
LCD Brightness Control Setting Please note Brightness Control can only be set by setting jumper JP14 for CCFL on the motherboard C48 V2.1. By default, the inverter is CCFL on the motherboard jumper setting.
111 Power on the system, and press the key when the system is booting up to enter the BIOS Setup utility. 222 Select the Advanced tab. 333 Select Power Configuration COM/VGA Ports and press to go to display the available options.
4. To change the brightness, select “Brightness Control” and press . Choose the desired brightness level (0~7) press . Save the change by pressing F10. NOTE: the new brightness will take effect after the system has restarted.
41
Intel Graphics Driver Setting 111 Right click Desktop. Find "Graphics Properties" and enter the manu.
2. Make sure the Display Device is same as follows.
42
No.
Output Interface
Connector & Jumper
Intel Graphics Driver Device Name
1st
LCD Panel
CN26
Notebook
2nd
VGA Port
JP3/6
Monitor
Appendix: Drivers Installation The shipping package includes a Driver CD in which you can find every individual driver and utility that enables you to install the drivers on the system. Please insert the Driver CD into the drive and double click on the “index.htm” to select the models. You can refer to the drivers installation guide for each driver in the “Driver/Manual List”.