Temperature Probes 7040 / 7140 Fe-CuNi, NiCr-Ni / Pt 100, Pt 500, Pt 1000 Technical Data Sheet grounded insulated 8 mm 10 mm installation length (EL) in mm G 1/4 G 3/8 G 1/2 insert length in mm Æ Æ FK-J NC e i 8 10 e.g. 90 43 44 82 e.g. 3000 A e.g. 400 measuring point 7040 1 Fe-CuNi type L number of thermocouples type kind of element 2 FK-L protecting tube cable length socket max. temperature in °C NiCr-Ni type K multicore cable ends temperature Fe-CuNi type J order index - thermocouple 7040 example: 7040.1.FK-L.e.8.90.44.3000.A.400 °C The small temperature probes type 7040 / 7140 are mainly used for the measuring of plastics processing machinery temperatures, pipe conduit temperatures, container temperatures, boiler temperatures etc. The thimble facilitates the change of probes when cables and containers are filled. These probes are available with one or two thermocouples / resistances. A compression spring is used as stretch equalizer. Maximum temperature is 400° C. cable length Description: Ø14 18 available types (7040): Fe-CuNi type L DIN 43710 (not for new installations) Fe-CuNi type J DIN EN 60584 NiCr-Ni type K DIN EN 60584 materials: protecting tube high-grade steel bayonet cap brass nickel-plated / brass nickel-plated socket brass nickel-plated spring high-grade steel (7040) cable with flexible fiberglass insulation and high-grade steel wire brading (7140) connecting cable with flexible fiberglass insulation and highgrade steel wire brading Ø 8-10 up to shaft (EL + 10) thread EL available types (7140): Pt 100 Kl. B DIN EN 60751 Pt 500 Kl. B DIN EN 60751 Pt 1000 Kl. B DIN EN 60751 (other tolerance classes on demand) (subject to technical alterations) Ø 6-8 G 3/8 G 1/2 insert length in mm multicore cable ends 8 10 e.g. 90 43 44 82 e.g. 3000 A e.g. 400 protecting tube cable length socket max. temperature in °C G 1/4 4-L installation length (EL) in mm 3-L 10 mm indicate only for 3- or 4-cable conduit indicate only for Pt 500 or Pt 1000 e.g. Pt 500 Æ 2 8 mm 1 temperature Æ 7140 number of resistances type order index – resistance thermometer 7140 example: 7140.1.10.90.44.3000.A.400 °C Please state diverging measures in plain text. For different connecting possibilities see ‘accessories’. Please indicate operating temperature and cable length! Gräff GmbH s Bonner Strasse 54 s D - 53842 Troisdorf s Tel: +49(0)2241-4907-0 s Fax: +49(0)2241-4907-77 Internet: http://www.graeff-gmbh.com E-Mail: [email protected]