Preview only show first 10 pages with watermark. For full document please download

Kcg562hae-dxxx

   EMBED


Share

Transcript

Emerson Climate Technologies (India) Limited COMPRESSOR MODEL KCG562HAE-DXXX BILL OF MATERIALS D511, D512, D513 Emerson Climate Technologies (India) Limited Karad Dhebewadi Road Karad - 415 110 INDIA Note – Sales compressor drawing number and compressor model name are the same. Prepared by Checked by Verified by Approved by 01 F25-1206-0591 Current EN No. A1 11.12.2006 Page No. --Last EN No. REV. No. DATE PED-QSP-ORG-02/09 Emerson Climate Technologies (India) Limited PRODUCT SPECIFICATION MODEL – KCG562HAE-DXXX A ) MODEL DESCRIPTION Model Name Compressor Type Application Group Evaporating Temperature Range Refrigerant Rated Voltage Compressor Cooling Typical Application Certifications & Approvals KCG562HAE-DXXX Reciprocating ,Connecting Rod Type High Temperature (HBP) -6.7°C To 12.8°C ( 20 °F To 55°F ) R - 22 400 V, 50 Hz, 3 Phase FAN : 420 ft3/ minute Air Conditioning ISI, EN60335-2-34 B ) PERFORMANCE SPECIFICATION @ RATED CONDITION Specification Unit Btu / h kcal / h W Nominal HP W Cooling Capacity Input Power Input Current Cooling Capacity EER = Input Power ASRE/T 52000 13100 15236 5.20 5250 8.5 ARI 50700 12775 14855 5.07 5250 Btu / W-h 9.9 9.66 kcal / W-h 2.50 2.43 A 8.5 S P E C I F I C A T I O N 2.90 W/W 2.83 Note – Above performance parameters are nominal values & subject to ± 5% variation C ) RATING CONDITIONS Parameter Evaporating Temperature Condensing Temperature Ambient Temperature Sub cooled Liquid Temp. Return Gas Temperature Test Voltage Prepared by Checked by Unit °C ( °F ) °C ( °F ) °C ( °F ) °C ( °F ) °C ( °F ) V Verified by ASRE/T 7.2 (45) 54.4 (130) 35 (95) 46.1 (115) 35 (95) 400 Approved by ARI 7.2 (45) 54.4 (130) 35 (95) 46.1 (115) 18.3 (65) 400 02 F44-0608-0323 Current EN No. A2 15.06.2008 Page No. F25-1206-0591 Last EN No. REV. No. DATE PED-QSP-ORG-02/09 Emerson Climate Technologies (India) Limited PRODUCT SPECIFICATION MODEL – KCG562HAE-DXXX D) MECHANICAL SPECIFICATION Parameter Unit Value Number of Cylinders Displacement Net Weight Number(s) cm3 / (inch3) / rev kg kg cm3 ( Oz ) Refrigeration Grade kg / cm2 ( psig ) W@V Three (3) 117.65 (7.18) 50.7 (111.54) 54.0 (118.8) 2250 (76) Mineral Approximate Shipping Weight Oil Charge Oil Type IPRV (Pressure Differential) Crank Case Heater 28.12 / 35.15 (400 / 500) 40 To 55 / 240 E ) ELECTRICAL SPECIFICATION Parameter Unit Value Operating Voltage Range Motor Circuit Electrical Accessories ¾ Start Capacitor ¾ Run Capacitor ¾ Relay ¾ Over Load Protector Lock Rotor Ampere ( LRA ) Maximum Continuous Current ( MCC ) Motor Insulation High Potential Test V ----- 360 To 460 3 Phase µF @ VAC µF @ VAC N/A N/A N/A ----A 49 A 14.3 --(kV/second/mA) B Class 2.3 / 1 / 5.5 Internal F ) OPERATING ENVELOPE @ 400 V, 50 Hz, 3 Phase Condensing Temp °F 150 140 130 120 110 100 90 10 20 30 40 50 60 Evaporating Temp °F SC1 Prepared by Checked by Verified by Approved by S P E C I F I C A T I O N 03 F44-0608-0323 Current EN No. A2 15.06.2008 Page No. F25-1206-0591 Last EN No. REV. No. DATE PED-QSP-ORG-02/09 Emerson Climate Technologies (India) Limited PRODUCT SPECIFICATION MODEL – KCG562HAE-DXXX PERFORMANCE TABLES Super heating Liquid Sub cooling Ambient temp. 11°C (20°F) 400V, 3Ph, 50Hz Voltage Compressor Cooling - 8.3°C (15°F) 35°C (95°F) 420 ft3 / minute A ) COOLING CAPACITY ( Btu / h ) Condensing Temperature °C 37.8 43.3 48.9 54.4 60.0 °F 100 110 120 130 140 Evaporating Temperature -6.7 20 37800 32300 27400 22900 --- -1.1 30 50700 45100 39900 34900 30100 4.4 40 63100 57200 51400 45800 40100 7.2 45 70300 64100 58100 50700 45800 10 50 78800 72300 65900 59400 52600 12.8 55 89000 82300 75400 66400 61100 B ) INPUT POWER ( W ) Condensing Temperature °C 37.8 43.3 48.9 54.4 60.0 °F 100 110 120 130 140 Evaporating Temperature -6.7 20 3500 3650 3730 3820 --- -1.1 30 3750 3860 3980 4100 4220 4.4 40 4420 4570 4720 4870 5010 7.2 45 4800 4960 5130 5250 5440 10 50 5130 5310 5490 5660 5810 12.8 55 5360 5550 4740 5910 6080 C ) INPUT CURRENT ( A ) Condensing Temperature °C 37.8 43.3 48.9 54.4 60.0 °F 100 110 120 130 140 Evaporating Temperature -6.7 20 6.0 6.1 6.2 6.4 --- -1.1 30 6.5 6.8 7.1 7.3 7.6 4.4 40 7.1 7.4 7.7 8.0 8.3 7.2 45 7.5 7.8 8.2 8.5 8.8 10 50 8.0 8.4 8.8 9.1 9.4 12.8 55 8.7 9.1 9.5 9.9 10.2 Note – 1. Nominal performance values (± 5%) based on 24 hours running. Subject to change without notice. 2. Compressor is intended to be operated in the range of condensing & evaporating temperature where performance values are specified in above tables. Prepared by Checked by Verified by Approved by S P E C I F I C A T I O N 04 F25-1206-0591 Current EN No. A1 11.12.2006 Page No. --Last EN No. REV. No. DATE PED-QSP-ORG-02/09 Emerson Climate Technologies (India) Limited DESIGN SPECIFICATION MODEL – KCG562HAE-DXXX A ) MECHANICAL SPECIFICATION Parameter Unit Value Cylinder Bore Diameter Crank Shaft Eccentricity Crank Shaft Stroke Approximate Internal Free Volume (without oil) Maximum Residual Moisture Maximum Internal Solid Residue / Impurities cm ( inch ) cm ( inch ) cm ( inch ) 4.526 (1.7822) 1.1798 (0.4645) 2.4356(0.959) cm3 ( inch3 ) 11750 (717.03) mg 200 mg 150 B ) ELECTRICAL SPECIFICATION Parameter Unit Value Motor Type Nominal Motor Speed --rpm 2 Pole, Induction, Three phase 2850 Nominal Motor Winding Resistance (@25°C) Ω 2.79 To 3.21 Nominal Motor Output Power Maximum Allowable Motor Winding Temperature Relay, Recommended Overload Relay Range Relay Setting Contactor Over Load Protector Type Part Number Disc Opening Temp. Disc Closing Temp. 1st cycle trip Current 1st cycle trip On time Terminal Fused Cluster Copper Wire Material kW 4.60 °F(°C) 266 (130) A A V AC 10 – 16 14.5 32 A, 220 coil ----°F (°C) °F (°C) A second ------- Internal 34HM-239-6 239 To 257 (115 To 125) 126 To 158 (52 To 70) 37 2 to 10 ¼” Quick Connect --- Base Coat – 65-75% of Polyster Imide Top Coat – 25-35 % of Polyamide Imide Copper Wire Enamel Designation Copper Wire Enamel Construction Prepared by Checked by Verified by Hermetic Grade Round Enameled H Class Approved by S P E C I F I C A T I O N 05 F25-1206-0591 Current EN No. A1 11.12.2006 Page No. --Last EN No. REV. No. DATE PED-QSP-ORG-02/09 Emerson Climate Technologies (India) Limited DESIGN SPECIFICATION MODEL – KCG562HAE-DXXX C ) PERFORMANCE SPECIFICATION Parameter Unit Value Bare Compressor Sound Bare Compressor Vibration Compressor Discharge Pulse dBA µm psi ------- D ) TEST CONDITIONS Parameter Voltage Unit Test Overload (High Load) Blocked Fan Low Voltage Start : Equalised Low Voltage Run V 400 --- Suction Pressure kg/cm2 (psig) 6.3 (90) --- Discharge Pressure kg/cm2 (psig) 28.1 (400) --- Top Shell Temperature Ambient Temperature °C ( °F ) °C (°F) 65 (149) -- 46 (115) -- 360 11.9 (169) 11.9 (169) 55 (131) 46 (115) 360 6.3 (90) 28.1 (400) 65 (149) 46 (115) Note – Above test conditions are only for orientation and not for customer product qualification E ) REFERENCE APPLICATION DETAILS Parameter Maximum Allowable Ambient Temperature Maximum Permissible Transient discharge Pressure Stabilised Maximum Discharge Line Temp. Maximum Return Gas Temperature Unit Value ° C (°F) 46 (115) kg / cm2 ( psig ) 29.5 (420) 28.1 (400) 130 (266) 27 (80) ° C (°F) ° C (°F) Note – Application Details are the guidelines for safe operation of Compressor. Prepared by Checked by Verified by Approved by S P E C I F I C A T I O N 06 F25-1206-0591 Current EN No. A1 11.12.2006 Page No. --Last EN No. REV. No. DATE PED-QSP-ORG-02/09