Transcript
DEEP CYCLE BATTERY KD12-100
FEATURES
12V100AH
APPLICATION
Low self-discharge and long shelf life Non-Spillable construction Safety valve installation for explosion proof Exceptional deep discharge recovery performance
Solar system
99.7% pure lead calcium grids and A recognized Component of U.L
Emergency Power System
Telecommunications 4WD Dual Battery system Caravan, Motorhome systems
SPECIFICATIONS Nominal Voltage
12V
Nominal Capacity
100Ah@20 hour rate F.V.(1.75V/cell)
Approx. Weight
25.5Kg (56.22lbs.)
Terminals
B3 (Fitting M6 bolt & nut) I2 is optional
Internal Resistance
≤Ω 5m
Max. Discharge Current
1000A (5 sec) 25A
Max. Charge Current
ISO 9001 ISO9000
(Fully Charged)
Charge: -10oC~40 oC (14 oF~104 oF) o o o o Discharge: -20 C~50 C (-4 F~122 F) o o o o Storage : -20 C~40 C (-4 F~104 F)
Operating Temperature Range
IEC 60896.2 JIS C 8704.2 GB/T 19638.2
o
Self Discharge
3% of capacity declined per month at (25 C)
DIMENSION(mm/inch)
TERMINAL TYPE
OUTER DIMENSIONS
Length 306±2.0mm (12.07 ±0.08inch)
Width
306mm(12.05inch)
169mm(6.65inch)
15mm (0.59inch)
210±2.0mm (8.27±0.08inch)
4mm (0.16inch)
210mm(8.27inch)
Container Height
215mm(8.46inch)
169±2.0mm (6.65±0.08inch)
M6mm (0.24inch)
Total Height Terminal Dimensions
Constant power discharge characteristics at 25°C/77°F
Unit:W
F.V/Time
5MIN
10MIN
15MIN
30MIN
1HR
3HR
5HR
10HR
20HR
Charge Voltage
1.60V 1.65V 1.70V 1.75V 1.80V 1.85V
519 492 460 428 384 286
358 354 345 322 300 230
279 276 272 256 240 192
178 175 170 166 160 132
117 113 110 109 107 94.4
47.2 47.0 46.7 46.4 45.8 42.5
32.9 32.9 32.8 32.5 32.0 28.8
19.1 18.8 18.7 18.3 18.0 17.3
9.49 9.45 9.44 9.41 9.08 8.86
Max. Current Cycle use
215±2.0mm (8.46±0.08inch)
Constant current discharge characteristics at 25°C/77°F
14.4-14.7V (±4mV)
25.0A
Unit:A
F.V/Time
5MIN
10MIN
15MIN
30MIN
1HR
3HR
5HR
10HR
20HR
1.60V 1.65V 1.70V 1.75V 1.80V 1.85V
315 284 269 239 216 182
216 197 190 176 163 149
158 153 148 140 133 128
94.5 91.8 90.0 88.2 85.5 81.4
59.4 59.3 59.1 58.5 57.8 56.2
24.6 24.5 24.5 24.3 24.2 23.8
17.2 17.1 17.0 16.9 16.8 16.2
9.55 9.41 9.35 9.19 9.03 8.88
5.11 5.08 5.05 5.00 4.94 4.86
VISIT US AT WWW.KICKASSPRODUCTS.COM.AU
Float Use
13.6-13.8V (±3mV)
DEEP CYCLE BATTERY KD12-100
Charge Characteristic
0.20
2.60
120
0.17
2.40
100
0.14
10
80 60 40 20
0.11 0.08 0.05 0.02
Charge Vo ltage (V/Cell)
140
Charge Capacity (%)
100
Charge Current (CA)
Trickle(or Float) Service Life
Design Life (Years)
12V100AH
Charge Voltage
2.20 Charge Capacity
2.00
.
1 Discharge 100%(0.05CA×20H) 50%(0.05CA×10H)
1.80
.
2 Charge
1.60 1.40
.
Charge Voltage 13.65V (2.275V/Cell) Charge Current 0.1CA o
Charge Current
0 10
20
30
40
50
0
60
0
0
0
o
8
4
Temperature ( C)
16
12
20
24
Charge Time (Hour)
Discharge Characteristic
Cycle Service Life
o
Terminal Voltage(V)
80
Cycle Life
60
40
20
o
25 C(77 F) 20oC(68oF)
13
100
Depth of Discharge (%)
o
3 Temperature 25 C(77 F)
12 11 0.17C 0.09C 0.05C
10
0.25C 0.6C
9 8 3C
2C
1C
0
0
500
1000
1500
2000
2500
3000
3500
0
4000
1
2
3
5
10
20 30
60
2
3
5
Min
Number of Cycle (Times)
10
20 30
Hour
Discharge Time (Hour)
Capacity Factors With Different Temperature Battery Type
-20o C
-10o C
0oC
5oC
10oC
20o C
25o C
30oC
40oC
45o C
GEL Battery
6V&12V
55%
75%
85%
88%
90%
98%
100%
102%
104%
105%
2V
65%
80%
88%
90%
92%
99%
100%
103%
105%
106%
AGM Battery
6V&12V
46%
66%
76%
83%
90%
98%
100%
103%
107%
109%
2V
55%
70%
80%
85%
92%
99%
100%
104%
108%
110%