Preview only show first 10 pages with watermark. For full document please download

Kd12 100

   EMBED


Share

Transcript

DEEP CYCLE BATTERY KD12-100 FEATURES 12V100AH APPLICATION Low self-discharge and long shelf life Non-Spillable construction Safety valve installation for explosion proof Exceptional deep discharge recovery performance Solar system 99.7% pure lead calcium grids and A recognized Component of U.L Emergency Power System Telecommunications 4WD Dual Battery system Caravan, Motorhome systems SPECIFICATIONS Nominal Voltage 12V Nominal Capacity 100Ah@20 hour rate F.V.(1.75V/cell) Approx. Weight 25.5Kg (56.22lbs.) Terminals B3 (Fitting M6 bolt & nut) I2 is optional Internal Resistance ≤Ω 5m Max. Discharge Current 1000A (5 sec) 25A Max. Charge Current ISO 9001 ISO9000 (Fully Charged) Charge: -10oC~40 oC (14 oF~104 oF) o o o o Discharge: -20 C~50 C (-4 F~122 F) o o o o Storage : -20 C~40 C (-4 F~104 F) Operating Temperature Range IEC 60896.2 JIS C 8704.2 GB/T 19638.2 o Self Discharge 3% of capacity declined per month at (25 C) DIMENSION(mm/inch) TERMINAL TYPE OUTER DIMENSIONS Length 306±2.0mm (12.07 ±0.08inch) Width 306mm(12.05inch) 169mm(6.65inch) 15mm (0.59inch) 210±2.0mm (8.27±0.08inch) 4mm (0.16inch) 210mm(8.27inch) Container Height 215mm(8.46inch) 169±2.0mm (6.65±0.08inch) M6mm (0.24inch) Total Height Terminal Dimensions Constant power discharge characteristics at 25°C/77°F Unit:W F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 3HR 5HR 10HR 20HR Charge Voltage 1.60V 1.65V 1.70V 1.75V 1.80V 1.85V 519 492 460 428 384 286 358 354 345 322 300 230 279 276 272 256 240 192 178 175 170 166 160 132 117 113 110 109 107 94.4 47.2 47.0 46.7 46.4 45.8 42.5 32.9 32.9 32.8 32.5 32.0 28.8 19.1 18.8 18.7 18.3 18.0 17.3 9.49 9.45 9.44 9.41 9.08 8.86 Max. Current Cycle use 215±2.0mm (8.46±0.08inch) Constant current discharge characteristics at 25°C/77°F 14.4-14.7V (±4mV) 25.0A Unit:A F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 3HR 5HR 10HR 20HR 1.60V 1.65V 1.70V 1.75V 1.80V 1.85V 315 284 269 239 216 182 216 197 190 176 163 149 158 153 148 140 133 128 94.5 91.8 90.0 88.2 85.5 81.4 59.4 59.3 59.1 58.5 57.8 56.2 24.6 24.5 24.5 24.3 24.2 23.8 17.2 17.1 17.0 16.9 16.8 16.2 9.55 9.41 9.35 9.19 9.03 8.88 5.11 5.08 5.05 5.00 4.94 4.86 VISIT US AT WWW.KICKASSPRODUCTS.COM.AU Float Use 13.6-13.8V (±3mV) DEEP CYCLE BATTERY KD12-100 Charge Characteristic 0.20 2.60 120 0.17 2.40 100 0.14 10 80 60 40 20 0.11 0.08 0.05 0.02 Charge Vo ltage (V/Cell) 140 Charge Capacity (%) 100 Charge Current (CA) Trickle(or Float) Service Life Design Life (Years) 12V100AH Charge Voltage 2.20 Charge Capacity 2.00 . 1 Discharge 100%(0.05CA×20H) 50%(0.05CA×10H) 1.80 . 2 Charge 1.60 1.40 . Charge Voltage 13.65V (2.275V/Cell) Charge Current 0.1CA o Charge Current 0 10 20 30 40 50 0 60 0 0 0 o 8 4 Temperature ( C) 16 12 20 24 Charge Time (Hour) Discharge Characteristic Cycle Service Life o Terminal Voltage(V) 80 Cycle Life 60 40 20 o 25 C(77 F) 20oC(68oF) 13 100 Depth of Discharge (%) o 3 Temperature 25 C(77 F) 12 11 0.17C 0.09C 0.05C 10 0.25C 0.6C 9 8 3C 2C 1C 0 0 500 1000 1500 2000 2500 3000 3500 0 4000 1 2 3 5 10 20 30 60 2 3 5 Min Number of Cycle (Times) 10 20 30 Hour Discharge Time (Hour) Capacity Factors With Different Temperature Battery Type -20o C -10o C 0oC 5oC 10oC 20o C 25o C 30oC 40oC 45o C GEL Battery 6V&12V 55% 75% 85% 88% 90% 98% 100% 102% 104% 105% 2V 65% 80% 88% 90% 92% 99% 100% 103% 105% 106% AGM Battery 6V&12V 46% 66% 76% 83% 90% 98% 100% 103% 107% 109% 2V 55% 70% 80% 85% 92% 99% 100% 104% 108% 110%