Preview only show first 10 pages with watermark. For full document please download

Kele Lighting Controls

   EMBED


Share

Transcript

MOTOR CONTROLS HUMIDITY MOTOR CONTROLS Kele Has Soft Starters and VFDs to Extend the Life of Your Motor and Help Save Energy and Maintenance Costs. Core VFD Series | p. 695 PSR Series | p. 681 FCXLS/NFCXLS | p. 692 MOTOR CONTROLS Products manufactured in the United States Products that are new to the catalog MODEL/SERIES PAGE Motor Disconnects ABB EOT Series — Enclosed Non-Fused Disconnect Switch. . . . . . . . . . . . . 689 BCXLS Series — Breaker Combination Motor Starters. . . . . . . . . . . . . . . . . . 690 FCXLS, NFCXLS Series — Fusible and Non-Fusible Motor Starters . . . . . . . 692 Motor Starters PSR Series — Softstarters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 681 A Series — ABB 3 Phase Motor Starter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 683 TEC Compact Starters — 3 Phase Motor Starters. . . . . . . . . . . . . . . . . . . . . 687 MOTOR CONTROLS A Series | p. 683 TEC Compact | p. 687 Starters Smart VFD | p. 704 HVAC kele.com Variable Frequency Drives (VFD) and Bypasses CORE VFD — Honeywell Variable Frequency Drives. . . . . . . . . . . . . . . . . . . . CORE VFD With Bypass — Honeywell Variable Frequency Drives. . . . . . . . . SmartDrive Compact VFD — Honeywell Compact Variable Frequency Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SMARTVFD HVAC — Honeywell All Purpose Variable Frequency Drives. . . . SMARTVFD HVAC With Bypass Assembly — Variable Frequency Drives with Bypass. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 695 698 702 704 707 NEW! MOTOR CONTROLS SOFTSTARTERS PSR SERIES DESCRIPTION Constant-speed AC motors are used to drive HVAC fans and pumps. During start and stop, both mechanical and electrical stresses are high, causing undesirable load peaks each time the motors are started. An ABB Softstarter eliminates many of these problems. The voltage is smoothly applied to, and removed from, the motor. Both the torque and the current consequently behave in the same way. The result is that mechanical and electrical stresses are significantly lower than with conventional starting methods. The PSR series Compact Softstarters range covers motor currents from 3 to 46A. All sizes include a Run signal relay. The 25A and above are also provided with an output signal for TOR (Top Of Ramp, i.e. full voltage). With standard performance the PSR Softstarters handle ten starts per hour. When an auxiliary cooling fan is added, the starting capacity is increased to 20 starts per hour. FEATURES PSR16-600-70 • • • • • Compact size • Easy to install and adjust • DIN rail or screw mounting PSR30-600-70 PSR45-600-70 Run signal relay 25A and above includes "Top Of Ramp" output signal Motor ratings up to 600 VAC and 40Hp Seperate Acceleration/ Deceleration times SPECIFICATIONS 100/ 240 V, 24 VDC 208 to 600 VAC 3.9A Starting capacity 15.6A for 6s 6.8A Starting capacity 27.2A for 6s 9A Starting capacity 36A for 6s 12A Starting capacity 48A for 6s 16A Starting capacity 64A for 6s 25A Starting capacity 100A for 6s 30A Starting capacity 120A for 6s 37A Starting capacity 148A for 6s 46A Starting capacity 180A for 6s Based on rated Voltage and FLA Acceleration Time Deceleration Time Altitude Limits Protection Rating LED Indication 1-10 seconds 0-20 seconds 13,123 ft. (4000 m) Main circuit IP20 Control Circuit IP20 On/ Ready Green On/ Ready Green Run/ Top of Ramp Green Run/ Top of Ramp Green Operating Temperature -13° to 140°F (-25° to 60°C) Storage Temperature -40° to 158°F (-40° to 70°C) Number of Starts/ hr 10 standard; 20 with Aux. Fan Approvals UL ListedFile E161428 Warranty 12 months from installation, maximum 18 months from factory WIRING Fuse (customer supplied) Circuit protection by customer Circuit protection by customer PSR Fuse (customer supplied) PSR Note: verify motor nameplate voltage and horsepower rating for soft starter selection Note: verify motor nameplate voltage and horsepower rating for soft starter selection March 2014 N/C COM L/+ N/C Supply Voltage Model PSR25 - 45 with MCCB COM L/+ Supply Voltage Model PSR3 - 16 with MCCB 12 MOTOR CONTROLS Supply Voltage Motor Voltage Rating Current Rating PSR3 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 Horsepower WE MAKE IT EASY. kele.com 888-397-5353 USA 681 NEW! MOTOR CONTROLS SOFTSTARTERS PSR SERIES ORDERING INFORMATION MOTOR CONTROLS 12 Model Control Supply Voltage Full Circuit Horsepower Load Breaker Fuse Size Amps 208V 240V 480V 600V Max. PSR3-600-70 100/ 240 V 3.4 .5 0.75 2 2 PSR6-600-70 100/ 240 V 6.1 1 1.5 3 PSR9-600-70 100/ 240 V 9 2 2 PSR12-600-70 100/ 240 V 11 3 PSR16-600-70 100/ 240 V 15.2 PSR25-600-70 100/ 240 V PSR30-600-70 Dimensions Weight 50 A 40 A J-Type 5.51" x 1.77" x 4.47" (140mm x 45mm x 113.5mm) 0.99 lbs. (0.45 kg) 5 50 A 40 A J-Type 5.51" x 1.77" x 4.47" (140mm x 45mm x 113.5mm) 0.99 lbs. (0.45 kg) 5 7.5 50 A 40 A J-Type 5.51" x 1.77" x 4.47" (140mm x 45mm x 113.5mm) 0.99 lbs. (0.45 kg) 3 7.5 10 50 A 40 A J-Type 5.51" x 1.77" x 4.47" (140mm x 45mm x 113.5mm) 0.99 lbs. (0.45 kg) 3 3 10 10 50 A 40 A J-Type 5.51" x 1.77" x 4.47" (140mm x 45mm x 113.5mm) 0.99 lbs. (0.45 kg) 24.2 7.5 7.5 15 20 50 A 40 A J-Type 6.30" x 1.77" x 5.04" (160mm x 45mm x 128mm) 1.43 lbs. (0.65 kg) 100/ 240 V 28 7.5 7.5 20 25 50 A 40 A J-Type 6.30" x 1.77" x 5.04" (160mm x 45mm x 128mm) 1.43 lbs. (0.65 kg) PSR37-600-70 100/ 240 V 34 10 10 25 30 50 A 40 A J-Type 7.36" x 1.77" x 6.02" (187mm x 45mm x 153mm) 2.20 lbs. (1.00 kg) PSR45-600-70 100/ 240 V 46.2 15 15 30 40 50 A 40 A J-Type 7.36" x 1.77" x 6.02" (187mm x 45mm x 153mm) 2.20 lbs. (1.00 kg) PSR3-600-81 24 VDC 3.4 .5 .5 2 2 50 A 40 A J-Type 5.51" x 1.77" x 4.47" (140mm x 45mm x 113.5mm) 2.20 lbs. (1.00 kg) PSR6-600-81 24 VDC 6.1 1 1 3 5 50 A 40 A J-Type 5.51" x 1.77" x 4.47" (140mm x 45mm x 113.5mm) 0.99 lbs. (0.45 kg) PSR9-600-81 24 VDC 9 2 2 5 7.5 50 A 40 A J-Type 5.51" x 1.77" x 4.47" (140mm x 45mm x 113.5mm) 0.99 lbs. (0.45 kg) PSR12-600-81 24 VDC 11 3 3 7.5 10 50 A 40 A J-Type 5.51" x 1.77" x 4.47" (140mm x 45mm x 113.5mm) 0.99 lbs. (0.45 kg) PSR16-600-81 24 VDC 15.2 3 3 10 10 50 A 40 A J-Type 5.51" x 1.77" x 4.47" (140mm x 45mm x 113.5mm) 0.99 lbs. (0.45 kg) PSR25-600-81 24 VDC 24.2 7.5 7.5 15 20 100 A 60 A J- Type 6.30" x 1.77" x 5.04" (160mm x 45mm x 128mm) 1.43 lbs. (0.65 kg) PSR30-600-81 24 VDC 28 7.5 10 20 25 100 A 70 A J- Type 6.30" x 1.77" x 5.04" (160mm x 45mm x 128mm) 1.43 lbs. (0.65 kg) PSR37-600-81 24 VDC 34 10 10 25 30 150 A 100 A J- Type 7.36" x 1.77" x 6.02" (187mm x 45mm x 153mm) 2.20 lbs. (1.00 kg) PSR45-600-81 24 VDC 46.2 15 15 30 40 150 A 100 A J- Type 7.36" x 1.77" x 6.02" (187mm x 45mm x 153mm) 2.20 lbs. (1.00 kg) PSR-FAN 682 888-397-5353 USA ACCESSORIES Cooling Fan for increased starting capacity (field-installable) kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS ABB 3 PHASE MOTOR STARTER A SERIES DESCRIPTION The A Series ABB starter line offers motor start/stop and protection. The double-break contacts allow stopping a motor with minimal conact wear. The thermal overloads are sized for the motor FLA and keep motor windings from over-heating during overload conditions. We offer these starters in open, enclosed, enclosed with fusible disconnect, and enclosed with circuit breaker. Auxiliary contacts are available for field installation. FEATURES • • • • • • • NEMA sizes 00 thru 5 UL508A panel program, file #E105450 Compact space-saving design Auxiliary contacts available Coil operates 85 to 110% of rated voltage Solid-state adjustable overload relays standard Conventional bimetallic overloads available A50NSF1-84A6B A9NS1-81E DIMENSIONS 12 Enclosed Starters in (cm) MODEL SIZE A9, A16, A26 A50, A75 A260 NEMA 1 fused 14"H x 12"W x 8"D (35.6 x 30.5 x 20.3 cm) 20"H x 16"W x 8"D (50.8 x 40.6 x 20.3 cm) 30"H x 24"W x 12"D (76.2 x 61.0 x 30.5 cm) 36"H x 30"W x 12"D (91.4 x 76.2 x 30.5 cm) NEMA 1 circuit breaker 14"H x 12"W x 8"D (35.6 x 30.5 x 20.3 cm) 14"H x 12"W x 8"D (35.6 x 30.5 x 20.3cm) 24"H x 20"W x 8"D (61.0 x 50.8 x 20.3 cm) 30"H x 24"W x 12"D (76.2 x 61.0 x 30.5 cm) Open Frame Starters in (cm) MODEL SIZE A9, A16 A26 A50, A75 A145 A260 March 2014 5.3"H x 1.7"W x 3.7"D (13.3 x 4.4 x 9.5 cm) 5.8"H x 2.1"W x 4.3"D (9.0 x 2.1 x 11.0 cm) 6.9"H x 2.8"W x 4.4"D (17.7 x 7.0 x 11.3 cm) 12.9"H x 4.1"W x 6.3"D (32.9 x 10.5 x 16.0 cm) 17.5"H x 5.5"W x 7.1"D (44.4 x 14 x 18.1 cm) WE MAKE IT EASY. kele.com 888-397-5353 USA MOTOR CONTROLS A145 NEMA 1 11"H x 6"W x 5"D (27.9 x 15.2 x 12.7 cm) 13"H x 9"W x 7"D (33.0 x 22.9 x 17.8 cm) 30"H x 24"W x 12"D (76.2 x 61.0 x 30.5 cm) 30"H x 24"W x 12"D (76.2 x 61.0 x 30.5 cm) 683 NEW! MOTOR CONTROLS ABB 3 PHASE MOTOR STARTER A SERIES WIRING Non-reversing, reversing AF09 - AF750, AFN00 - AFN4 L1 Incoming Lines L1 L2 L3 Disconnect 1 3 5 2 4 6 Fuse Disconnect 3 1 External Control Supply Standard 120 VAC Breaker CX2 CX1 5 2-1 1-1 X1 X2 2 L1 M T1 1-2 2-2 L2 L3 T2 T3 4 6 OL 97 OL 95 3-1 98 96 3-7 3-2 3-2 3-6 JUMPER OL T1 3-3 14 M A2 15 3-4 3-4 T3 T2 1 12 A1 OL 2 * MOTOR Disconnect MOTOR CONTROLS Incoming Lines L1 L2 L3 Remote Contact Customer 1 3 5 2 4 6 Fuse Disconnect 1 3 Breaker 5 External Control Supply Standard 120 VAC CX1 2 4 CX2 6 2-1 1-1 1-2 2-2 3-7 X2 X1 L1 L2 L3 L1 L2 3-6 L3 R T2 T3 T1 T2 F 3-2 3-2 JUMPER F T1 R T3 14 3-5 01 21 13 R 3-3 14 01 21 F 01 22 A1 F A2 01 22 A1 R A2 13 3-4 3-4 OL T1 T2 T3 3 1 2 4 * F MOTOR * R All units ship with a NO and NC contacts. Additional contacts can be added in the field. 684 888-397-5353 USA kele.com Remote Contact Customer WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS ABB 3 PHASE MOTOR STARTER A SERIES WIRING 2 speed, 1 winding; 2 speed, 2 winding AF09 - AF75 Disconnect Incoming Lines L1 L2 L3 1 3 5 2 4 6 Fuse Disconnect 1 3 5 2 4 6 Breaker External Control Supply Standard 120VAC CX1 CX2 2-1 1-1 1-2 2-2 3-7 SOL FOL X2 L1 L3 L1 X1 L2 L3 T2 T3 T1 T2 T3 S T1 95 96 95 96 3-6 3-2 3-2 F S 3-9 14 3-5 Jumper L2 F 01 21 13 F 3-3 14 01 22 A1 01 22 A1 S 01 21 S A2 F A2 13 3-4 3-4 FOL SOL T1 T2 T3 T1 T2 3 T2 * 12 T3 1 2 4 * S T13 T12 T1 MOTOR T11 * F Disconnect 3 5 2 4 6 1 3 Remote Contact Customer Breaker External Control Supply Standard 120VAC 5 CX1 2 4 MOTOR CONTROLS 1 Fuse Disconnect CX2 6 1-2 2-2 2-1 1-1 SOL FOL 95 96 95 96 3-7 3-2 3-2 1F 3-6 S Jumper 3-9 3-5 14 01 21 13 2F 3-3 14 S 01 21 13 1 01 22 21 22 A1 13 A1 1F 14 S A2 2F A2 1F A2 A1 3-4 3-4 3 01 22 2F 2 4 * S All units ship with a NO and NC contacts. Additional contacts can be added in the field. March 2014 * F Remote Contact Customer WE MAKE IT EASY. kele.com 888-397-5353 USA 685 NEW! MOTOR CONTROLS ABB 3 PHASE MOTOR STARTER A SERIES WIRING Non-reversing, single phase AF09 - AF110, AFN00 - AFN2 L1 Incoming Lines L1 L2 X1 Disconnect 1 3 5 2 4 6 Fuse Disconnect 1 3 External Control Supply Standard 120 VAC Breaker 2-1 1-1 OL X2 97 2 L1 T1 4 6 L3 T2 3-1 98 OL 95 96 1-2 2-2 3-7 3-2 3-2 3-6 JUMPER M L2 CX2 CX1 5 T3 A1 OL 3-3 14 M A2 15 3-4 3-4 OL T1 T2 1 T3 2 * All units ship with a NO and NC contacts. Additional contacts can be added in the field. MOTOR 12 Remote Contact Customer ORDERING INFORMATION MOTOR CONTROLS NEMA SIZE 00 0 1 2 3 4 5 MOTOR HORSEPOWER 3-PHASE, 1800 RPM** 200V 230V 460V – – 1/4 – 1/4 1/3, 1/2 – 1/3 3/4 1/3, 1/4 1/2 1 1/2 – – 3/4 3/4 1.5, 2 – 1 – 1 1.5 – 1.5 – – – – 3 2 2 5 3 3 – – – 7.5 5 5 10 7.5 7.5 – – – 15 – 10 20 10 15 25 – – – 15 – 30 20 20 40 25 25, 30 50 – – – – – 60 30 40 75 40 50 100 50 – – 60 60 125 – 100 200 575V 1/2 – 3/4 1 1.5, 2 – – – – 5 – – 10 – – 20 25 – 30 40 50 – 60 75 100 – 125 150 – OVERLOAD RELAY MODEL SETTING OPEN STYLE RANGE A9N00S-*E 0.63 - 1.0 A9N00S-*F 1.0 - 1.4 A9N00S-*G 1.3 - 1.6 A9N00S-*H 1.7 - 2.4 A9N00S-*J 2.2 - 3.1 A9N00S-*K 2.8 - 4.0 A9N00S-*L 3.5 - 5.0 A9N00S-*M 4.5 - 6.5 A9N00S-*N 6.0 - 8.5 A16N0S-*M 4.5 - 6.5 A16N0S-*N 6.0 - 8.5 A16N0S-*P 7.5 - 11 A26N1S-*Q 10 - 14 A26N1S-*R 13 - 19 A26N1S-*S 18 - 25 A50N2S-*A 18 - 25 A50N2S-*B 22 - 32 A50N2S-*C 29 - 42 A75N3S-*C 29 - 42 A75N3S-*D 36 - 52 A75N3S-*E 45 - 63 A75N3S-*F 60 - 80 A145N4S-*R 65 - 90 A145N4S-*A 65 - 90 A145N4S-*B 65 - 90 A145N4S-*C 65 - 90 A260N5S-*T 110 - 150 A260N5S-*A 130 - 185 A260N5S-*C 220 - 310 MODEL NEMA 1 ENCLOSED A9NS1-*E A9NS1-*F A9NS1-*G A9NS1-*H A9NS1-*J A9NS1-*K A9NS1-*L A9NS1-*M A9NS1-*N A16NS1-*M A16NS1-*N A16NS1-*P A26NS1-*Q A26NS1-*R A26NS1-*S A50NS1-*A A50NS1-*B A50NS1-*C A75NS1-*C A75NS1-*D A75NS1-*E A75NS1-*F A145NS1-*R A145NS1-*A A145NS1-*B A145NS1-*C A260NS1-*T A260NS1-*A A260NS1-*C MODEL NEMA 1 ENCL. FUSIBLE DISCONNECT A9NSF1-*E6A A9NSF1-*F6A A9NSF1-*G6A A9NSF1-*H6A A9NSF1-*J6A A9NSF1-*K6A A9NSF1-*L6A A9NSF1-*M6A A9NSF1-*N6A A16NSF1-*M6A A16NSF1-*N6A A16NSF1-*P6A A26NSF1-*Q6A A26NSF1-*R6A A26NSF1-*S6A A50NSF1-*A6B A50NSF1-*B6B A50NSF1-*C6B A75NSF1-*C6C A75NSF1-*D6C A75NSF1-*E6C A75NSF1-*F6C A145NSF1-*R6E A145NSF1-*A6E A145NSF1-*B6E A145NSF1-*C6E A260NSF1-*T6E A260NSF1-*A6E A260NSF1-*C6E FUSE CLIP SIZE CLASS J 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 60A 60A 60A 100A 100A 100A 100A 400A 400A 400A 400A 400A 400A 400A MODEL NEMA 1 ENCL. W/CIRCUIT BREAKER A9NSM1-*E4A A9NSM1-*F4A A9NSM1-*G4A A9NSM1-*H4A A9NSM1-*J4B A9NSM1-*K4B A9NSM1-*L4C A9NSM1-*M4C A9NSM1-*N4C A16NSM1-*M4C A16NSM1-*N4C A16NSM1-*P4D A26NSM1-*Q4D A26NSM1-*R4D A26NSM1-*S4E A50NSM1-*A4E A50NSM1-*B4E A50NSM1-*C4E A75NSM1-*C4E A75NSM1-*D4F A75NSM1-*E4F A75NSM1-*F4F A145NSM1-*R4F A145NSM1-*A4F A145NSM1-*B4F A145NSM1-*C4F A260NSM1-*T4H A260NSM1-*A4H A260NSM1-*C4J CIRCUIT BREAKER RATING (480 V MAX) 3 3 3 3 5 5 10 10 10 10 10 25 25 25 50 50 50 50 50 100 100 100 100 100 100 100 250 250 400 *Insert code 84 for 120 VAC 60Hz, code 80 for 240 VAC, code 81 for 24 VAC 50/60 Hz **Check full load amp rating on motor nameplate to ensure proper overload protection Note - for additional auxiliary contacts add suffix 10 for 1 N.O., 20 for 2 N.O., 01 for 1 N.C., 02 for 2 N.C., 11 for 1 N.O. & 1 N.C. Example: A50N2S-84A-20 Open frame style, 10 HP, 120 VAC coil, 2 N.O. auxiliary contacts 686 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS 3 PHASE MOTOR STARTERS TEC COMPACT STARTERS DESCRIPTION TEC Compact Starters are compact 3 phase motor starters. They have an enameled copper wire coil and have fingersafe contacts.These starters are UL 508SB rated. There is an external window indicator that shows contact wear. FEATURES • • • • • • Compact design cULus, CE, and UL508 approved Available with reset or start stop NEMA 4X enclosed Single or three phase Class 10 overloads TEC18-AKSS3-18A SPECIFICATIONS HORSE POWER - 3PHASE Part Number TEC12-A4XR-8A 200V 2 230V 2.5 480V 5 600V 7.5 Coil Voltage 120V Enclosure NEMA Rating 4X Control Type/ Version Reset only Overload Amp Weight Range lbs (kg) 5.5 - 8A 2.3 (1.04) TEC12-G4XR-8A 2 2.5 5 7.5 24V 4X Reset only 5.5 - 8A 2.3 (1.04) TEC12-AKSS3-8A 2 2.5 5 7.5 120V 4X Start/stop 5.5 - 8A 2.3 (1.04) TEC12-GKSS3-8A 2 2.5 5 7.5 24V 4X Start/stop 5.5 - 8A 2.3 (1.04) TEC12-A4XR-13A 3 3 7.5 10 120V 4X Reset only 9 - 13A 2.3 (1.04) TEC12-G4XR-13A 3 3 7.5 10 24V 4X Reset only 9 - 13A 2.3 (1.04) TEC12-AKSS3-13A 3 3 7.5 10 120V 4X Start/stop 9 - 13A 2.3 (1.04) TEC12-GKSS3-13A 3 3 7.5 10 24V 4X Start/stop 9 - 13A 2.3 (1.04) TEC18-A4XR-18A 5 5 10 15 120V 4X Reset only 7 - 10A 2.3 (1.04) 5 5 10 15 24V 4X Reset only 7 - 10A 2.3 (1.04) 5 5 10 15 120V 4X Start/stop 7 - 10A 2.3 (1.04) TEC18-GKSS3-18A 5 5 10 15 24V 4X Start/stop 7 - 10A 2.3 (1.04) TEC25-A4XR-25A 5 7.5 15 20 120V 4X Reset only 17- 25A 2.7 (1.22) TEC25-G4XR-25A 5 7.5 15 20 24V 4X Reset only 17- 25A 2.7 (1.22) TEC25-AKSS3-25A 5 7.5 15 20 120V 4X Start/stop 17- 25A 2.7 (1.22) TEC25-GKSS3-25A 5 7.5 15 20 24V 4X Start/stop 17- 25A 2.7 (1.22) Other options and models available from manufacturer. DIMENSIONS A B C D E TEC12, TEC18 Starters 4.72" (11.98 cm) 5.51" (18.99 cm) 6.54" (16.61 cm) 5.9" (14.98 cm) 3.46" (8.78 cm) TEC25 Starter 5.31" (13.48 cm) 6.1" (15.49 cm) 7.28" (18.49 cm) 6.5" (16.51 cm) 3.98" (10.10 cm) E B March 2014 D C A WE MAKE IT EASY. MOTOR CONTROLS TEC18-G4XR-18A TEC18-AKSS3-18A 12 kele.com 888-397-5353 USA 687 NEW! MOTOR CONTROLS 3 PHASE MOTOR STARTERS TEC COMPACT STARTERS WIRING STOP L1(X1) 13 M A1 14 (A) M A2 (B) START 95 96 OL RESET 17 18 START-STOP PUSHBUTTONS Series TEC…KSS3…* STOP L1(X1) 13 M 14 A1 (A) START M A2 (B) 95 L2(X2) L2 L1 L1 L3 L1 L2 L1 L2 L2 M M 13 14 Aux. NO L2(X2) 96 OL T1 OL RESET 17 18 REMOTE START-STOP PUSHBUTTONS Series TEC…4XR… (Reset only)* * L2 on control circuit should be connected to neutral for 120V control voltage. Dashed lines indicate field connection. T2 T3 OL T1 T2 MTR MTR THREE-PHASE* SINGLE-PHASE* ORDERING INFORMATION MOTOR CONTROLS 12 MODEL TEC12-A4XR-8A TEC12-G4XR-8A TEC12-AKSS3-8A TEC12-GKSS3-8A TEC12-A4XR-13A TEC12-G4XR-13A TEC12-AKSS3-13A TEC12-GKSS3-13A TEC18-A4XR-18A TEC18-G4XR-18A TEC18-AKSS3-18A TEC18-GKSS3-18A TEC25-A4XR-25A TEC25-G4XR-25A TEC25-AKSS3-25A TEC25-GKSS3-25A DESCRIPTION Compact starter, 3 phase, 120 VAC, with reset and overload,5.5 to 8 Amps Compact starter, 3 phase, 24 VAC, with reset and overload, 5.5 to 8 Amps Compact starter, 3 phase, 120 VAC, start/stop and overload, 5.5 to 8 Amps Compact starter, 3 phase, 24 VAC, start/stop and overload, 5.5 to 8 Amps Compact starter, 3 phase, 120 VAC, with reset and overload, 9 to 13 Amps Compact starter, 3 phase, 24 VAC, with reset and overload, 9 to 13 Amps Compact starter, 3 phase, 120 VAC, start/stop and overload, 9 to 13 Amps Compact starter, 3 phase, 24 VAC, start/stop and overload, 9 to 13 Amps Compact starter, 3 phase, 120 VAC, with reset and overload, 12 to 18 Amps Compact starter, 3 phase, 24 VAC, with reset and overload, 12 to 18 Amps Compact starter, 3 phase, 120 VAC, start/stop and overload, 12 to 18 Amps Compact starter, 3 phase, 24 VAC, start/stop and overload, 12 to 18 Amps Compact starter, 3 phase, 120 VAC, with reset and overload, 17 to 25 Amps Compact starter, 3 phase, 24 VAC, with reset and overload, 17 to 25 Amps Compact starter, 3 phase, 120 VAC, start/stop and overload, 17 to 25 Amps Compact starter, 3 phase, 24 VAC, start/stop and overload, 17 to 25 Amps ACCESSORIES EEC0.63-1A Overload relay TEC Series/0.63-1 Amps EEC1-1.6A Overload relay TEC Series/1-1.6 Amps EEC1.6-2.5A Overload relay TEC Series/1.6-2.5 Amps EEC2.5-4A Overload relay TEC Series/2.5-4 Amps EEC4-6A Overload relay TEC Series/4-6 Amps EEC5.5-8A Overload relay TEC Series/5.5-8 Amps EEC7-10A Overload relay TEC Series/7-10 Amps EEC9-13A Overload relay TEC Series/9-13 Amps EEC12-18A Overload relay TEC Series/12-18 Amps EEC17-25A Overload relay TEC Series/17-25 Amps 688 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS ENCLOSED NON-FUSED DISCONNECT SWITCH ABB EOT SERIES DESCRIPTION The EOT Series of enclosed manual motor controllers are rotary operated, 3 pole, 600V Hp rated switches, housed in thermoplastic/polycarbonate enclosures suitable for wet and corrosive environments. These NEMA 3R/12 models are equipped with selector style handles. They are compact in size have touch safe operation. cUL/IEC-47-3 approvals and UL508 listed. FEATURES • • • • • • • • Suitable as motor disconnect Horsepower rated Touch safe construction Positive operation Clear position indication Self lifting tunnel terminals Extremely compact size Accessories include 4th Power Pole & Snap-on auxiliary contacts • OSHA Lock Out/Tag Out Selector switch style WIRING SPECIFICATIONS Supply Voltage 600V MAX Enclosure Rating NEMA 3R/12 Auxiliary Contacts (optional) Maximum number allowed: 2NO + 1NC Meets ARRA or BAA Yes Dimensions, Including Handle EOT16 & EOT32 6.36"H x 3.94"W x 4.55"D (16.2 x 10 x 11.6 cm) EOT45 7.87"H x 5.75"W x 5.43"D (19.8 x 14.6 x 18.8 cm) EOT63 11.81"H x 8.27"W x 7.12"D (30 x 21 x 181 cm) Approvals UL Listed E63822, IEC947-3, UL 508 Note: Only 1 additional pole per switch allowed MODEL EOT16U3P3-S EOT16U3P3-1S EOT16U3P3-S1 EOT16U3P3-1S1 EOT32U3P3-S EOT32U3P3-1S EOT32U3P3-S1 EOT32U3P3-1S1 EOT45U3P3-S EOT45U3P3-1S EOT45U3P3-S1 EOT45U3P3-1S1 EOT63U3P3-P EOT63U3P3-1P EOT63U3P3-P1 EOT63U3P3-1P1 March 2014 DESCRIPTION Black selector handle; 16 Amp rating Black selector handle; 16 Amp rating; 1 NO auxiliary contact Red/Yellow selector handle; 16 Amp rating Red/Yellow selector handle; 16 Amp rating; 1 NO auxiliary contact Black selector handle; 40 Amp rating Black selector handle; 40 Amp rating; 1 NO auxiliary contact Red/Yellow selector handle; 40 Amp rating Red/Yellow selector handle; 40 Amp rating; 1 NO auxiliary contact Black selector handle; 60 Amp rating Black selector handle; 60 Amp rating; 1 NO auxiliarycontact Red/Yellow selector handle; 60 Amp rating Red/Yellow selector handle; 60 Amp rating; 1 NO auxiliary contact Black pistol handle; 80 Amp rating Black pistol handle; 80 Amp rating; 1 NO auxiliary contact Red/Yellow pistol handle; 80 Amp rating Red/Yellow pistol handle; 80 Amp rating; 1 NO auxiliary contact Short Circuit protective device Controller 12 Overload protection EOT Motor disconnect EOT products are properly installed on the load side of a branch circuit protective device and are suitable for use as motor disconnects as illustrated above. HORSEPOWER RATINGS Model Series eOT16 Three Phase Max HP 200-208V 3 240V 6 480V 10 600V 10 Single Phase Max HP 120V 1 240V 2 eOT32 eOT45 eOT63 10 10 20 25 15 15 30 30 20 20 40 40 2 5 2 7.5 2 10 MOTOR CONTROLS ORDERING INFORMATION Disconnect means ACCESSORIES OA1G01 Auxiliary contact NC, mounts on left side of switch only OA1G10 Auxiliary contact, NO mounts on right side of switch only OTPL40FP 4th Pole, late-break/early-make function (eOT16 & eOT32) OTPL80FP 4th Pole, late-break/early-make function (eOT45 & eOT63) OTPS40FP 4th Pole (EOT16 & eOT32) OTPS80FP 4th Pole (EOT45 & eOT63) WE MAKE IT EASY. kele.com 888-397-5353 USA 689 NEW! MOTOR CONTROLS BREAKER COMBINATION MOTOR STARTERS BCXLS SERIES DESCRIPTION Breaker combnation motor starters are UL508. They include 600 Volt internatinally accepted industrial control breakers with instantaneous and thermal trip. They all have door handle safety interlocks and pilot lights. Magnetic starters with percision and consisten overload protection and different single phasing protection. FEATURES • • • • • • • • Breakers with instantaneous and thermal trip NEMA 1 or NEMA 12/4 enclosure Space and drilling for fused control circuit transformer HOA switch Pilot light Door safety interlocks 24V or 120V coil voltage UL File #E90628 BCXLS11K-1G-0N-M01-H0A-PL WIRING TRANSFORMER PILOT LIGHTS H1(L1) ON PL H4(L2) R A1 H3 H2 L1 12 21 X1 M OFF PL 22 G FU X1 A2 BREAKER COMBINATION L2 X2 L1 X2 L2 L3 CONTROL CIRCUIT L1 MOTOR CONTROLS X1 HAND OFF AUTO 13 14 23 24 A1 A2 M OL 95 96 L2 L2 X2 A1 H1 H4 13 M 2 1 14 Aux. NO REMOTE SWITCH L1 X1 STOP 21 22 START A1 13 14 A2 M OL 95 X2 A1 M A2 95 96 L2 OL 96 OL X2 T1 T2 T3 AUX 13 14 MTR OFF ON L1 A1 X1 13 14 A2 M OL 95 96 L2 X2 FUSIBLE CONTROL TRANSFORMERS Model B050MBT713RK B100MBT713RK B150MBT713RK B200MBT713RK B250MBT713RK B300MBT713RK B350MBT713RK 690 Primary Volts 208V, 230V, 460V 208V, 230V, 460V 208V, 230V, 460V 208V, 230V, 460V 208V, 230V, 460V 208V, 230V, 460V 208V, 230V, 460V 888-397-5353 USA Secondary Volts Continuous VA 115V, 24V 50VA 115V, 24V 100VA 115V, 24V 150VA 115V, 24V 200VA 115V, 24V 250VA 115V, 24V 300VA 115V, 24V 350VA kele.com Contactors to use with LS07,4,7,17,27,37, LS05,4K,7K,11K,18K LS47,57,77,87,107 ,LS22K,30K,37K,45K, LS55K LS177, LS75K LS90K(3P) LS247 LS110K, 132K, 160K LS220K, 280K, 375K LS450K Height 3.25" (83 mm) 3.62"(92 mm) 4.37" (111 mm) 4.5" (114 mm) 5.25" (133 mm) 5.12" (130 mm) 5.37" (137 mm) WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. Width 3.0" (76 mm) 3.75" (95 mm) 3.75" (95 mm) 4.5" (114 mm) 4.5" (114 mm) 5.25" (133 mm) 5.25" (133 mm) Depth 3.93" (100 mm) 4.55" (76 mm) 4.55" (76 mm) 5.18" (132 mm) 5.18" (132 mm) 6.12" (155 mm) 6.12" (155 mm) March 2014 NEW! MOTOR CONTROLS BREAKER COMBINATION MOTOR STARTERS BCXLS SERIES ORDERING INFORMATION/SPECIFICATIONS Part Number March 2014 Voltage 5 200/230 Coil Voltage 24 VAC 120 VAC 24 VAC 10 460 120 VAC 24 VAC 7.5 230 120 VAC 24 VAC 15 460 120 VAC 24 VAC 10 200 120 VAC 24 VAC 10 230 120 VAC 24 VAC 20 460 120 VAC 24 VAC 15 200/230 120 VAC 24 VAC 30 460 120 VAC 24 VAC 20/25 200/230 120 VAC 24 VAC 50 460 120 VAC 24 VAC 25/30 200/230 120 VAC 24 VAC 60 460 120 VAC 24 VAC 40 230 120 VAC 75 460 40/50 200/230 24 VAC 24 VAC 120 VAC 24 VAC 100 460 120 VAC Enclosure Coil NEMA Rating Inrush 1 12/4 45 VA 1 12/4 1 12/4 45 VA 1 12/4 1 12/4 88 VA 1 12/4 1 12/4 88 VA 1 12/4 1 12/4 88 VA 1 12/4 1 12/4 88 VA 1 12/4 1 12/4 88 VA 1 12/4 1 12/4 191 VA 1 12/4 1 12/4 191 VA 1 12/4 1 12/4 191 VA 1 12/4 1 12/4 191 VA 1 12/4 1 12/4 191 VA 1 12/4 1 12/4 191 VA 1 12/4 1 12/4 191 VA 1 12/4 1 12/4 191 VA 1 12/4 1 12/4 400 VA 1 12/4 1 12/4 400 VA 1 12/4 Coil Holding Current Overload Breaker Range Rating Dimensions in (lb) Weight lb (kg) 6 VA 14.5-18 Amps 30A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 31 (14.1) 6 VA 14.5-18 Amps 30A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 31 (14.1) 9 VA 21-26 Amps 50A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 32 (14.5) 9 VA 21-26 Amps 50A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 32 (14.5) 9 VA 30-40 Amps 80A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 33 (15) 9 VA 30-40 Amps 80A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 33 (15) 9 VA 30-40 Amps 80A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 33 (15) 17 VA 54-65 Amps 125A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 45 (20.4) 17 VA 42-55 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 45 (20.4) 17 VA 64-82 Amps 150A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 47 (21.3) 17 VA 64-82 Amps 150A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 47 (21.3) 17 VA 78-97 Amps 150A 24" x 20" x 8" (61 x 50.8 x 20.3) 61 (27.7) 17 VA 78-97 Amps 150A 24" x 20" x 8" (61 x 50.8 x 20.3) 61 (27.7) 17 VA 90-110 Amps 175A 24" x 20" x 8" (61 x 50.8 x 20.3) 63 (28.6) 17 VA 90-110 Amps 175A 24" x 20" x 8" (61 x 50.8 x 20.3) 63 (28.6) 32 VA 140-190 Amps 225A 30" x 24" x 8" (76.2 x 61 x 20.3) 97 (44) 32 VA 140-190 Amps 225A 30" x 24" x 8" (76.2 x 61 x 20.3) 97 (44) WE MAKE IT EASY. kele.com 888-397-5353 USA 12 MOTOR CONTROLS BCXLS7K-1G-O-M01-HOA-PL BCXLS7K-1G-O-M4-HOA-PL BCXLS7K-1A-O-M01-HOA-PL BCXLS7K-1A-O-M4-HOA-PL BCXLS7K-2G-O-M01-HOA-PL BCXLS7K-2G-O-M4-HOA-PL BCXLS7K-2A-O-M01-HOA-PL BCXLS7K-2A-O-M4-HOA-PL BCXLS11K-1G-ON-M01-HOA-PL BCXLS11K-1G-ON-M4-HOA-PL BCXLS11K-1A-ON-M01-HOA-PL BCXLS11K-1A-ON-M4-HOA-PL BCXLS11K-2G-ON-M01-HOA-PL BCXLS11K-2G-ON-M4-HOA-PL BCXLS11K-2A-ON-M01-HOA-PL BCXLS11K-2A-ON-M4-HOA-PL BCXLS15K-1G-Q-M01-HOA-PL BCXLS15K-1G-Q-M4-HOA-PL BCXLS15K-1A-Q-M01-HOA-PL BCXLS15K-1A-Q-M4-HOA-PL BCXLS15K-2G-Q-M01-HOA-PL BCXLS15K-2G-Q-M4-HOA-PL BCXLS15K-2A-Q-M01-HOA-PL BCXLS15K-2A-Q-M4-HOA-PL BCXLS15K-3G-Q-M01-HOA-PL BCXLS15K-3G-Q-M4-HOA-PL BCXLS15K-3A-Q-M01-HOA-PL BCXLS15K-3A-Q-M4-HOA-PL BCXLS22K-1G-RN-M01-HOA-PL BCXLS22K-1G-RN-M4-HOA-PL BCXLS22K-1A-RN-M01-HOA-PL BCXLS22K-1A-RN-M4-HOA-PL BCXLS22K-2G-QN-M01-HOA-PL BCXLS22K-2G-QN-M4-HOA-PL BCXLS22K-2A-QN-M01-HOA-PL BCXLS22K-2A-QN-M4-HOA-PL BCXLS37K-1G-SN-M01-HOA-PL BCXLS37K-1G-SN-M4-HOA-PL BCXLS37K-1A-SN-M01-HOA-PL BCXLS37K-1A-SN-M4-HOA-PL BCXLS37K-2G-SN-M01-HOA-PL BCXLS37K-2G-SN-M4-HOA-PL BCXLS37K-2A-SN-M01-HOA-PL BCXLS37K-2A-SN-M4-HOA-PL BCXLS45K-1G-TM-M01-HOA-PL BCXLS45K-1G-TM-M4-HOA-PL BCXLS45K-1A-TM-M01-HOA-PL BCXLS45K-1A-TM-M4-HOA-PL BCXLS45K-2G-TM-M01-HOA-PL BCXLS45K-2G-TM-M4-HOA-PL BCXLS45K-2A-TM-M01-HOA-PL BCXLS45K-2A-TM-M4-HOA-PL BCXLS55K-1G-TN-M01-HOA-PL BCXLS55K-1G-TN-M4-HOA-PL BCXLS55K-1A-TN-M01-HOA-PL BCXLS55K-1A-TN-M4-HOA-PL BCXLS55K-2G-TN-M01-HOA-PL BCXLS55K-2G-TN-M4-HOA-PL BCXLS55K-2A-TN-M01-HOA-PL BCXLS55K-2A-TN-M4-HOA-PL BCXLS75K-1G-TT-M01-HOA-PL BCXLS75K-1G-TT-M4-HOA-PL BCXLS75K-1A-TT-M01-HOA-PL BCXLS75K-1A-TT-M4-HOA-PL BCXLS75K-2G-TT-M01-HOA-PL BCXLS75K-2G-TT-M4-HOA-PL BCXLS75K-2A-TT-M01-HOA-PL BCXLS75K-2A-TT-M4-HOA-PL HP 691 NEW! MOTOR CONTROLS FUSIBLE AND NON-FUSIBLE MOTOR STARTERS FCXLS, NFCXLS SERIES DESCRIPTION Fusible and Non-Fusible combination controls for your motor. These have UL/CSA manual motor disconnects with door safety interlocks. Industrial controls disconnects are load make, load break, UL listed for motor load switching duty. Starter and overload relay complete with precision ambient compensated heaters and differential single phasing protection. FEATURES • • • • • • • NEMA 1 or NEMA 12/4 enclosure Space and drilling for fused control circuit transformer HOA switch Pilot light Door safety interlocks 24V or 120V coil voltage UL File #E90628 FCXLS7K-2A-0-M4-HOA-PL WIRING TRANSFORMER PILOT LIGHTS H1(L1) H4(L2) ON PL R A1 H3 H2 L1 FU 12 21 X1 X1 M OFF PL 22 G A2 L2 FUSIBLE COMBINATION X2 L1 X2 L2 L3 CONTROL CIRCUIT L1 X1 HAND OFF 13 AUTO A1 14 M A2 OL 95 96 L2 L2 X2 A1 MOTOR CONTROLS H1 23 24 1 H4 2 M REMOTE SWITCH L1 X1 STOP 21 22 A1 A2 OL 95 96 M L2 95 X2 M T1 A1 X1 96 T2 T3 MTR OFF ON L1 OL OL 14 AUX 13 14 13 A1 A2 START 13 X2 14 M A2 OL 95 96 L2 X2 FUSIBLE CONTROL TRANSFORMERS Model B050MBT713RK B100MBT713RK B150MBT713RK B200MBT713RK B250MBT713RK B300MBT713RK B350MBT713RK 692 Primary Volts 208V, 230V, 460V 888-397-5353 USA Secondary Volts Continuous VA Contactors to use with 50VA LS07,4,7,17,27,37, LS05,4K,7K,11K,18K 100VA LS47,57,77,87,107 ,LS22K,30K,37K,45K, LS55K 150VA LS177, LS75K LS90K(3P) 115V, 24V 200VA LS247 LS110K, 132K, 160K 250VA LS220K, 280K, 375K 300VA LS450K 350VA kele.com Height Width 3.25" (83mm) 3.0" (76mm) 3.62"(92mm) 3.75" (95mm) 4.37" (111mm) 3.75" (95mm) 4.5" (114mm) 4.5" (114mm) 5.25" (133mm) 4.5" (114mm) 5.12" (130mm) 5.25" (133mm) 5.37" (137mm) 5.25" (133mm) WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. Depth 3.93" (100mm 4.55" (76mm) 4.55" (76mm) 5.18" (132mm) 5.18" (132mm) 6.12" (155mm) 6.12" (155mm) March 2014 NEW! MOTOR CONTROLS FUSIBLE AND NON-FUSIBLE MOTOR STARTERS FCXLS, NFCXLS SERIES ORDERING INFORMATION - FCXLS Part Number FCXLS7K-1G-O-M01-HOA-PL FCXLS7K-1G-O-M4-HOA-PL FCXLS7K-1A-O-M01-HOA-PL FCXLS7K-1A-O-M4-HOA-PL FCXLS7K-2G-O-M01-HOA-PL FCXLS7K-2G-O-M4-HOA-PL FCXLS7K-2A-O-M01-HOA-PL FCXLS7K-2A-O-M4-HOA-PL FCXLS11K-1G-ON-M01-HOA-PL FCXLS11K-1G-ON-M4-HOA-PL FCXLS11K-1A-ON-M01-HOA-PL FCXLS11K-1A-ON-M4-HOA-PL FCXLS11K-2G-ON-M01-HOA-PL FCXLS11K-2G-ON-M4-HOA-PL FCXLS11K-2A-ON-M01-HOA-PL FCXLS11K-2A-ON-M4-HOA-PL FCXLS15K-1G-Q-M01-HOA-PL FCXLS15K-1G-Q-M4-HOA-PL FCXLS15K-1A-Q-M01-HOA-PL FCXLS15K-1A-Q-M4-HOA-PL FCXLS15K-2G-Q-M01-HOA-PL FCXLS15K-2G-Q-M4-HOA-PL FCXLS15K-2A-Q-M01-HOA-PL FCXLS15K-2A-Q-M4-HOA-PL FCXLS15K-3G-Q-M01-HOA-PL FCXLS15K-3G-Q-M4-HOA-PL March 2014 Voltage 5 200/230 10 460 Coil Enclosure Coil Coil Holding Overload Fuse Block Voltage NEMA Rating Inrush Current Range Rating 24 VAC 120 VAC 24 VAC 120 VAC 7.5 230 15 460 10 200 10 230 20 460 15 200/230 30 460 20/25 200/230 50 460 25/30 200/230 60 460 40 230 75 460 40/50 200/230 100 460 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 24 VAC 120 VAC 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 1 12/4 14.5-18 Dimensions in (cm) Weight lb (kg) 30A 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.16) 30A 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.16) 45 VA 6 VA 45 VA 6 VA 88 VA 9 VA 21-26 Amps 60A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 18 (8.16) 88 VA 9 VA 21-26 Amps 30A 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.16) 18 (8.16) 18 (8.16) 18 (8.16) 88 VA 9 VA 30-40 Amps 60A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2) 88 VA 9 VA 30-40 Amps 60A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2) 88 VA 9 VA 30-40 Amps 60A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2) 191 VA 17 VA 54-65 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 41 (18.6) 191 VA 17 VA 42-55 Amps 60A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 41 (18.6) 191 VA 17 VA 64-82 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 42 (19.1) 191 VA 17 VA 64-82 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 42 (19.1) 191 VA 17 VA 78-97 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 44 (20) 191 VA 17 VA 78-97 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 44 (20) 191 VA 17 VA 90-110 Amps 200A 30" x 24" x 8" (76.2 x 61 x 20.3) 88 (40) 191 VA 17 VA 90-110 Amps 200A 30" x 24" x 8" (76.2 x 61 x 20.3) 88 (40) 400 VA 32 VA 140-190 Amps 200A 36" x 24" x 10" (91.4 x 61 x 25.4) 124 (56.2) 400 VA 32 VA 140-190 Amps 200A 36" x 24" x 10" (91.4 x 61 x 25.4) 124 (56.2) 14.5-18 Amps WE MAKE IT EASY. kele.com 888-397-5353 USA 12 MOTOR CONTROLS FCXLS15K-3A-Q-M01-HOA-PL FCXLS15K-3A-Q-M4-HOA-PL FCXLS22K-1G-RN-M01-HOA-PL FCXLS22K-1G-RN-M4-HOA-PL FCXLS22K-1A-RN-M01-HOA-PL FCXLS22K-1A-RN-M4-HOA-PL FCXLS22K-2G-QN-M01-HOA-PL FCXLS22K-2G-QN-M4-HOA-PL FCXLS22K-2A-QN-M01-HOA-PL FCXLS22K-2A-QN-M4-HOA-PL FCXLS37K-1G-SN-M01-HOA-PL FCXLS37K-1G-SN-M4-HOA-PL FCXLS37K-1A-SN-M01-HOA-PL FCXLS37K-1A-SN-M4-HOA-PL FCXLS37K-2G-SN-M01-HOA-PL FCXLS37K-2G-SN-M4-HOA-PL FCXLS37K-2A-SN-M01-HOA-PL FCXLS37K-2A-SN-M4-HOA-PL FCXLS45K-1G-TM-M01-HOA-PL FCXLS45K-1G-TM-M4-HOA-PL FCXLS45K-1A-TM-M01-HOA-PL FCXLS45K-1A-TM-M4-HOA-PL FCXLS45K-2G-TM-M01-HOA-PL FCXLS45K-2G-TM-M4-HOA-PL FCXLS45K-2A-TM-M01-HOA-PL FCXLS45K-2A-TM-M4-HOA-PL FCXLS55K-1G-TN-M01-HOA-PL FCXLS55K-1G-TN-M4-HOA-PL FCXLS55K-1A-TN-M01-HOA-PL FCXLS55K-1A-TN-M4-HOA-PL FCXLS55K-2G-TN-M01-HOA-PL FCXLS55K-2G-TN-M4-HOA-PL FCXLS55K-2A-TN-M01-HOA-PL FCXLS55K-2A-TN-M4-HOA-PL FCXLS75K-1G-TT-M01-HOA-PL FCXLS75K-1G-TT-M4-HOA-PL FCXLS75K-1A-TT-M01-HOA-PL FCXLS75K-1A-TT-M4-HOA-PL FCXLS75K-2G-TT-M01-HOA-PL FCXLS75K-2G-TT-M4-HOA-PL FCXLS75K-2A-TT-M01-HOA-PL FCXLS75K-2A-TT-M4-HOA-PL HP 693 NEW! MOTOR CONTROLS FUSIBLE AND NON-FUSIBLE MOTOR STARTERS FCXLS, NFCXLS SERIES ORDERING INFORMATION - NFCXLS Part Number MOTOR CONTROLS 12 NFCXLS7K-1G-O-M01-HOA-PL NFCXLS7K-1G-O-M4-HOA-PL NFCXLS7K-1A-O-M01-HOA-PL NFCXLS7K-1A-O-M4-HOA-PL NFCXLS7K-2G-O-M01-HOA-PL NFCXLS7K-2G-O-M4-HOA-PL NFCXLS7K-2A-O-M01-HOA-PL NFCXLS7K-2A-O-M4-HOA-PL NFCXLS11K-1G-ON-M01-HOA-PL NFCXLS11K-1G-ON-M4-HOA-PL NFCXLS11K-1A-ON-M01-HOA-PL NFCXLS11K-1A-ON-M4-HOA-PL NFCXLS11K-2G-ON-M01-HOA-PL NFCXLS11K-2G-ON-M4-HOA-PL NFCXLS11K-2A-ON-M01-HOA-PL NFCXLS11K-2A-ON-M4-HOA-PL NFCXLS15K-1G-Q-M01-HOA-PL NFCXLS15K-1G-Q-M4-HOA-PL NFCXLS15K-1A-Q-M01-HOA-PL NFCXLS15K-1A-Q-M4-HOA-PL NFCXLS15K-2G-Q-M01-HOA-PL NFCXLS15K-2G-Q-M4-HOA-PL NFCXLS15K-2A-Q-M01-HOA-PL NFCXLS15K-2A-Q-M4-HOA-PL NFCXLS15K-3G-Q-M01-HOA-PL NFCXLS15K-3G-Q-M4-HOA-PL NFCXLS15K-3A-Q-M01-HOA-PL NFCXLS15K-3A-Q-M4-HOA-PL NFCXLS22K-1G-RN-M01-HOA-PL NFCXLS22K-1G-RN-M4-HOA-PL NFCXLS22K-1A-RN-M01-HOA-PL NFCXLS22K-1A-RN-M4-HOA-PL NFCXLS22K-2G-QN-M01-HOA-PL NFCXLS22K-2G-QN-M4-HOA-PL NFCXLS22K-2A-QN-M01-HOA-PL NFCXLS22K-2A-QN-M4-HOA-PL NFCXLS37K-1G-SN-M01-HOA-PL NFCXLS37K-1G-SN-M4-HOA-PL NFCXLS37K-1A-SN-M01-HOA-PL NFCXLS37K-1A-SN-M4-HOA-PL NFCXLS37K-2G-SN-M01-HOA-PL NFCXLS37K-2G-SN-M4-HOA-PL NFCXLS37K-2A-SN-M01-HOA-PL NFCXLS37K-2A-SN-M4-HOA-PL NFCXLS45K-1G-TM-M01-HOA-PL NFCXLS45K-1G-TM-M4-HOA-PL NFCXLS45K-1A-TM-M01-HOA-PL NFCXLS45K-1A-TM-M4-HOA-PL NFCXLS45K-2G-TM-M01-HOA-PL NFCXLS45K-2G-TM-M4-HOA-PL NFCXLS45K-2A-TM-M01-HOA-PL NFCXLS45K-2A-TM-M4-HOA-PL NFCXLS55K-1G-TN-M01-HOA-PL NFCXLS55K-1G-TN-M4-HOA-PL NFCXLS55K-1A-TN-M01-HOA-PL NFCXLS55K-1A-TN-M4-HOA-PL NFCXLS55K-2G-TN-M01-HOA-PL NFCXLS55K-2G-TN-M4-HOA-PL NFCXLS55K-2A-TN-M01-HOA-PL NFCXLS55K-2A-TN-M4-HOA-PL NFCXLS75K-1G-TT-M01-HOA-PL NFCXLS75K-1G-TT-M4-HOA-PL NFCXLS75K-1A-TT-M01-HOA-PL NFCXLS75K-1A-TT-M4-HOA-PL NFCXLS75K-2G-TT-M01-HOA-PL NFCXLS75K-2G-TT-M4-HOA-PL NFCXLS75K-2A-TT-M01-HOA-PL NFCXLS75K-2A-TT-M4-HOA-PL 694 HP Voltage 5 200/230 10 460 7.5 230 15 460 10 200 10 230 20 460 15 200/230 30 460 20/25 200/230 50 460 25/30 200/230 60 460 40 230 75 460 40/50 200/230 100 460 888-397-5353 USA kele.com Coil Enclosure Coil Voltage NEMA Rating Inrush 1 24 VAC 12/4 45 VA 1 120 VAC 12/4 1 24 VAC 12/4 45 VA 1 120 VAC 12/4 1 24 VAC 12/4 88 VA 1 120 VAC 12/4 1 24 VAC 12/4 88 VA 1 120 VAC 12/4 1 24 VAC 12/4 88 VA 1 120 VAC 12/4 1 24 VAC 12/4 88 VA 1 120 VAC 12/4 1 24 VAC 12/4 88 VA 1 120 VAC 12/4 1 24 VAC 12/4 191 VA 1 120 VAC 12/4 1 24 VAC 12/4 191 VA 1 120 VAC 12/4 1 24 VAC 12/4 191 VA 1 120 VAC 12/4 1 24 VAC 12/4 191 VA 1 120 VAC 12/4 1 12/4 24 VAC 191 VA 120 VAC 1 12/4 1 24 VAC 12/4 191 VA 1 120 VAC 12/4 1 24 VAC 12/4 191 VA 1 120 VAC 12/4 1 24 VAC 12/4 191 VA 1 120 VAC 12/4 1 24 VAC 12/4 400 VA 1 120 VAC 12/4 1 24 VAC 12/4 400 VA 1 120 VAC 12/4 Coil Holding Current Overload Range Dimensions in (cm) Weight lb (kg) 6 VA 14.5-18 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 17 (7.7) 6 VA 14.5-18 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 17 (7.7) 9 VA 21-26 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 17 (7.7) 9 VA 21-26 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 17 (7.7) 9 VA 30-40 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.2) 9 VA 30-40 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.2) 9 VA 30-40 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.2) 17 VA 54-65 Amps 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2) 17 VA 42-55 Amps 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2) 17 VA 64-82 Amps 16" x 12" x 8" (40.6 x 30.5 x 20.3) 28 (12.7) 17 VA 64-82 Amps 16" x 12" x 8" (40.6 x 30.5 x 20.3) 28 (12.7) 17 VA 78-97 Amps 20" x 16" x 8" (50.8 x 40.6 x 20.3) 38 (17.2) 17 VA 78-97 Amps 20" x 16" x 8" (50.8 x 40.6 x 20.3) 38 (17.2) 17 VA 90-110 Amps 20" x 16" x 8" (50.8 x 40.6 x 20.3) 40 (18.1) 17 VA 90-110 Amps 20" x 16" x 8" (50.8 x 40.6 x 20.3) 40 (18.1) 32 VA 140-190 Amps 24" x 20" x 8" (60.1 x 50.8 x 20.3) 65 (29.4) 32 VA 140-190 Amps 24" x 20" x 8" (60.1 x 50.8 x 20.3) 65 (29.4) WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS HONEYWELL VARIABLE FREQUENCY DRIVES CORE VFD DESCRIPTION CORE VFDs are an economical option drive option with easy to set up functionality. The firmware includes special features that make start-up and commissioning of HVAC applications especially easy. The Wizard consists of critical commissioning questions to intuitively guide users through parameter setup process, which covers nearly all your commercial heating, ventilation and air conditioning (HVAC) applications. Additionally, the VFD CORE is rated for constant torque for industrial applications. The CORE VFD line is also available with a bypass option which is also easy to integrate. The by-pass comes with a control transformer, time delay fuses, 3 contactors, primary and secondary fuses. The CORE line of VFDs is a time saver as well as an energy saver. FEATURES • • • • • Intuitive commissioning Start-up wizard Real-time clock Detachable keypad PID with sleep control HCRDA005DA1000T SPECIFICATIONS Supply Voltage Relay Outputs Filter Type 2; SPDT 8A at 24VDC or 250 VAC 0.4A at 125 VDC minimum load 10mA at 5 VAC/VDC 5% DC choke (Frame D and E standard; 3% built in) -- Optional for frames A, B, C Class 2 GMC/ RFI EMC Complies with EN50082-1, -2 EN61800-3 Communication Protocol RS485 MODBUS, BACnet Operating Humidity 0 to 90% RH, non-condensing Operating Temperature 14° to 104°F (-10° to 40°C) Approvals UL Listed File E190898, CE, RoHS Eco Friendly Yes Warranty 3 years DIMENSIONS AND WEIGHTS Frame 208/230 VAC 460 VAC A B B C C C D D E E E 1.0 - 7.5 HP 10 - 15 HP 20 HP 25 - 40 HP 1.0 - 10 HP 15 HP 20 - 25 HP March 2014 50 - 60 HP 75 HP 100 HP 125 HP 30 - 40 HP 50 HP 60 - 75 HP 100 - 125 HP Enclosure NEMA type NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 Width in (cm) 5.12 (13.0) 7.48 (19.0) 7.48 (19.0) 9.84 (25.0) 9.84 (25.0) 9.84 (25.0) 12.99 (33.0) 12.99 (33.0) 14.57 (37.0) 14.57 (37.0) 14.57 (37.0) Height in (cm) 9.84 (25.0) 12.6 (32.0) 12.6 (32.0) 15.75 (40.0) 15.75 (40.0) 15.75 (40.0) 27.10 (68.83) 27.10 (68.83) 28.18 (71.58) 28.18 (71.58) 28.18 (71.58) WE MAKE IT EASY. kele.com Depth in (cm) 6.69 (17.0) 7.48 (19.0) 7.48 (19.0) 8.27 (21.0) 8.27 (21.0) 8.27 (21.0) 10.83 (27.5) 10.83 (27.5) 11.81 (30.0) 11.81 (30.0) 11.81 (30.0) 888-397-5353 USA 12 MOTOR CONTROLS Model specific, 3 phase, 60 Hz, 380-480 VAC or 200-240 VAC Motor Rating 0.75 to 250 Hp Frequency Range 0-320 Hz Acceleration Time 0.1 - 3000 seconds Deceleration Time 0.1 - 3000 seconds Digital Input 6 logical, 24 VDC= on, 0 VDC= off, all configurable Analog Input 2; 0-010v or 4-20 mA voltage Input impedance 200Ω k Current impedance 250Ω Digital Output Open collector, max. load 48V/ 50 mA Analog Output 1; 0-10 VDC or 4-20 mA programmable 500Ω maximum load Weight lb (kg) 6.17 (2.8) 10.14 (4.6) 12.35 (5.6) 23.15 (10.5) 19.18 (8.7) 20.72 (9.4) 78.26 (35.5) 89.29 (40.5) 100.75 (45.7) 101.85 (46.2) 120.59 (54.7) 695 NEW! MOTOR CONTROLS HONEYWELL VARIABLE FREQUENCY DRIVES CORE VFD WIRING DC CHOKE (OPTIONAL) 3-PHASE POWER IS PROVIDED JUMPER BREAKING RESISTOR (OPTIONAL) FUSE/NO FUSE BREAKER R(L1) NFB R(L1) U(T1) S(L2) S(L2) V(T2) T(L3) T(L3) W(T3) 3-PHASE POWER IS PROVIDED MOTOR +1/DC+ FRAME E IM 3~ R r S s -/DC+ U(T1) MOTOR IM 3~ V(T2) W(T3) FUSE/NO FUSE BREAKER R(L1) NFB FACTORY SETTING: PNP SOURCE RA1 (RELAY OUT 1): RUN RA2 (RELAY OUT 2): FAULT RA3 (RELAY OUT 3): READY DCM COM FACTORY SETTING +24V +24V FWD/STOP REV/STOP PRESET SPD 1 PRESET SPD 2 PRESET SPD3 PRESET SPD 4 EXT FAULT FAULT RESET NA NA FWD REV MI1 MI2 MI3 MI4 MI5 MI6 MI7 MI8 DIGITAL SIGNAL COMMON TERMINAL WHILE USING INTERNAL POWER TO RUN SINK MODE POWER REMOVAL SAFETY FUNCTION FOR EMERGENCY STOP DIGITAL SIGNAL COMMON TERMINAL +10V/20mA 12 3 5KΩ 2 1 0~10V/0~20mA 0-20mA/0~10V 0~+10V ANALOG SIGNAL COMMON TERMINAL MAIN CIRCUIT (POWER) TERMINALS MODBUS RS-485 CONTROL SG+ PIN 1~2, 7, 8: TERMINALS RESERVED SGSHIELDED PIN 3, 6: GND LEADS & PIN 4: SGCABLES PIN 5: SG+ MOTOR CONTROLS MULTI-FUNCTION OUTPUT TERMINALS RA1 RB1 RC1 RA2 RC2 RA3 DCM S1 RC3 S(L2) T(L3) T(L3) FACTORY SETTING: PNP SOURCE DCM 250VAC/6A 30VDC/6A FACTORY SETTING MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A 30VDC/5A MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A R(L1) S(L2) COM +24V +24V FWD REV MI1 MI2 MI3 MI4 MI5 MI6 MI7 MI8 FWD/STOP REV/STOP PRESET SPD 1 PRESET SPD 2 PRESET SPD 3 PRESET SPD 4 EXT FAULT FAULT RESET NA NA DIGITAL SIGNAL COMMON TERMINAL WHILE USING INTERNAL POWER TO RUN SINK MODE 30VDC/5A POWER REMOVAL SAFETY FUNCTION FOR EMERGENCY STOP DIGITAL SIGNAL COMMON TERMINAL SCM +10V AVI1 AFM1 ACI ACM AVI2 ACM AFM2 8 1 8 1 +10V/20mA ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA 5KΩ ANALOG SIGNAL COMMON TERMINAL 3 2 1 0~10V/0~20mA 0-20mA/0~10V ANALOG SIGNAL COMMON TERMINAL OPTION SLOT 1 COMMUNICATION EXTENSION CARD OPTION SLOT 3 I/O & RELAY EXTENSION CARD MAIN CIRCUIT (POWER) TERMINALS CONTROL TERMINALS MI: MULTIFUNCTION INPUT AVI: ANALOG VOLTAGE INPUT ACI: ANALOG CURRENT INPUT MULTI-FUNCTION OUTPUT TERMINALS RA1 RB1 MODBUS RS-485 SG+ PIN 1~2, 7, 8: RESERVED SGPIN 3, 6: GND PIN 4: SGPIN 5: SG+ 30VDC/6A RA2 250VAC/5A RC2 RA3 DCM S1 RC3 AVI1 MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 30VDC/5A AFM1 ACI ACM AVI2 ACM AFM2 30VDC/5A MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A SCM 8 1 8 1 250VAC/6A RC1 +10V 0~+10V ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA RA1 (RELAY OUT 1): RUN RA2 (RELAY OUT 2): FAULT RA3 (RELAY OUT 3): READY ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA ANALOG SIGNAL COMMON TERMINAL ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA OPTION SLOT 1 COMMUNICATION EXTENSION CARD OPTION SLOT 3 I/O & RELAY EXTENSION CARD SHIELDED LEADS & CABLES MI: MULTIFUNCTION INPUT AVI: ANALOG VOLTAGE INPUT ACI: ANALOG CURRENT INPUT Frame Sizes D and E Frame Sizes A, B, and C M1 M2 M8 DCM COM +24V INTERNAL CIRCUIT Source Mode with internal power (+24 VDC) 696 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS HONEYWELL VARIABLE FREQUENCY DRIVES CORE VFD ORDERING INFORMATION March 2014 DESCRIPTION Core VFD 230 V, 2 HP, NEMA 1 Core VFD 230 V, 3 HP, NEMA 1 Core VFD 230 V, 5 HP, NEMA 1 Core VFD 230 V, 7.5 HP, NEMA 1 Core VFD 230 V, 10 HP, NEMA 1 Core VFD 230 V, 15 HP, NEMA 1 Core VFD 230 V, 20 HP, NEMA 1 Core VFD 230 V, 25 HP, NEMA 1 Core VFD 230 V, 30 HP, NEMA 1 Core VFD 230 V, 40 HP, NEMA 1 Core VFD 230 V, 50 HP, NEMA 1 Core VFD 230 V, 60 HP, NEMA 1 Core VFD 230 V, 75 HP, NEMA 1 Core VFD 230 V, 100 HP, NEMA 1 Core VFD 230 V, 125 HP, NEMA 1 Core VFD 460 V, 1 HP, NEMA 1 Core VFD 460 V, 2 HP, NEMA 1 Core VFD 460 V, 3 HP, NEMA 1 Core VFD 460 V, 5 HP, NEMA 1 Core VFD 460 V, 7.5 HP, NEMA 1 Core VFD 460 V, 10 HP, NEMA 1 Core VFD 460 V, 15 HP, NEMA 1 Core VFD 460 V, 20 HP, NEMA 1 Core VFD 460 V, 25 HP, NEMA 1 Core VFD 460 V, 30 HP, NEMA 1 Core VFD 460 V, 40 HP, NEMA 1 Core VFD 460 V, 50 HP, NEMA 1 Core VFD 460 V, 60 HP, NEMA 1 Core VFD 460 V, 75 HP, NEMA 1 Core VFD 460 V, 100 HP, NEMA 1 Core VFD 460 V, 125 HP, NEMA 1 Core VFD 230 V, 1 HP, NEMA 1 WE MAKE IT EASY. kele.com 12 MOTOR CONTROLS MODEL HCRDA0020A1000T HCRDA0030A1000T HCRDA0050A1000T HCRDA0075A1000T HCRDA0100B1000T HCRDA0150B1000T HCRDA0200B1000T HCRDA0250C1000T HCRDA0300C1000T HCRDA0400C1000T HCRDA0500D1000T HCRDA0600D1000T HCRDA0750E1000T HCRDA1000E1000T HCRDA1250E1000T HCRDC0010A1000T HCRDC0020A1000T HCRDC0030A1000T HCRDC0050A1000T HCRDC0075A1000T HCRDC0100A1000T HCRDC0150B1000T HCRDC0200B1000T HCRDC0250B1000T HCRDC0300C1000T HCRDC0400C1000T HCRDC0500C1000T HCRDC0600D1000T HCRDC0750D1000T HCRDC1000D1000T HCRDC1250D1000T HCRDA0010A1000T 888-397-5353 USA 697 NEW! MOTOR CONTROLS HONEYWELL VARIABLE FREQUENCY DRIVES CORE VFD WITH BYPASS DESCRIPTION The CORE VFD with a bypass option comes with a control transformer, time delay fuses, three contactors, primary and secondary fuses. CORE VFDs are an economical option drive option with easy to set up functionality. The firmware includes special features that make start-up and commissioning of HVAC applications especially easy. The Wizard consists of critical commissioning questions to intuitively guide users through a parameter setup process, which covers nearly all your commercial heating, ventilation and air conditioning (HVAC) applications. Additionally, the VFD CORE is rated for constant torque for industrial applications. The CORE line of VFDs is a time saver as well as an energy saver. FEATURES • • • • • Intuitive commissioning Start-up wizard Real-time clock Detachable keypad PID with sleep control Core VFD with Bypass MOTOR CONTROLS 12 SPECIFICATIONS Supply Voltage Model specific, 3 phase, 60 Hz, 380480 VAC or 200-240 VAC Motor Rating 0.75 to 250 Hp Frequency Range 0-320 Hz Acceleration Time 0.1 - 3000 seconds Deceleration Time 0.1 - 3000 seconds Digital Inputs 6 logical, 24 VDC = on, 0 VDC = off, all configurable Analog Input 2; 0-010V or 4-20 mA voltage Input Impedance 200Ω k Current Impedance 250Ω Digital Output Open collector, max. load 48V/ 50 mA Analog Output 1; 0-10 VDC or 4-20 mA programmable 500Ω maximum load Relay Outputs Filter Type 2; SPDT 8A at 24VDC or 250 VAC 0.4A at 125 VDC minimum load 10mA at 5 VAC/VDC 5% DC choke optional on frames A, B, and C Class 2 GMC/ RFI EMC Complies with EN50082-1, -2 EN61800-3 Communication Protocol RS485 MODBUS, BACnet Operating Humidity 0 to 90% RH, non-condensing Operating Temperature 14° to 104°F (-10° to 40°C) Approvals UL Listed File #E190898, CE, RoHS Eco Friendly Yes Warranty 3 years DIMENSIONS AND WEIGHTS Frame 208/230 VAC 460 VAC Enclosure NEMA type Width in (cm) Height in (cm) Depth in (cm) Weight lb (kg) A 1.0 - 7.5 HP 1.0 - 10 HP NEMA 1 8.9 (22.7) 22.0 (55.9) 9.3 (23.6) 37.0 (16.78) 698 B 10 - 20 HP 15 - 25 HP NEMA 1 12.4 (31.6) 48.0 (121.9) 9.66 (24.5) 67.0(30.39) C 25 - 40 hp 30 - 50 HP NEMA 1 12.4 (31.6) 48.0 (121.9) 9.66 (24.5) 83.0 (37.65) D 50 - 60 HP 60 - 125 HP NEMA 1 19.5 (49.7) 53.5 (135.9) 11.4 (29.1) 193.0 (87.54) E 75 - 125 HP NEMA 1 23.0 (48.3) 66.5 (168.9) 14.4 (36.7) 225 (102.06) 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS HONEYWELL VARIABLE FREQUENCY DRIVES CORE VFD WITH BYPASS WIRING DC CHOKE (OPTIONAL) 3-PHASE POWER IS PROVIDED JUMPER BREAKING RESISTOR (OPTIONAL) FUSE/NO FUSE BREAKER R(L1) NFB R(L1) MOTOR U(T1) S(L2) S(L2) V(T2) T(L3) T(L3) W(T3) IM 3~ FACTORY SETTING: PNP SOURCE RA1 (RELAY OUT 1): RUN RA2 (RELAY OUT 2): FAULT RA3 (RELAY OUT 3): READY DCM COM FACTORY SETTING +24V +24V FWD/STOP REV/STOP PRESET SPD 1 PRESET SPD 2 PRESET SPD3 PRESET SPD 4 EXT FAULT FAULT RESET NA NA FWD REV MI1 MI2 MI3 MI4 MI5 MI6 MI7 MI8 DIGITAL SIGNAL COMMON TERMINAL WHILE USING INTERNAL POWER TO RUN SINK MODE +10V/20mA 3 2 1 0~10V/0~20mA 0-20mA/0~10V 0~+10V ANALOG SIGNAL COMMON TERMINAL MAIN CIRCUIT (POWER) TERMINALS MODBUS RS-485 CONTROL SG+ PIN 1~2, 7, 8: TERMINALS RESERVED SGSHIELDED PIN 3, 6: GND LEADS & PIN 4: SGCABLES PIN 5: SG+ RA1 250VAC/6A RB1 30VDC/6A RC1 RA2 MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A RC2 30VDC/5A RA3 DCM S1 MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A RC3 30VDC/5A SCM +10V AVI1 ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA AFM1 ACI ACM AVI2 ACM AFM2 8 1 8 1 12 ANALOG SIGNAL COMMON TERMINAL ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA OPTION SLOT 1 COMMUNICATION EXTENSION CARD OPTION SLOT 3 I/O & RELAY EXTENSION CARD MOTOR CONTROLS POWER REMOVAL SAFETY FUNCTION FOR EMERGENCY STOP DIGITAL SIGNAL COMMON TERMINAL 5KΩ MULTI-FUNCTION OUTPUT TERMINALS MI: MULTIFUNCTION INPUT AVI: ANALOG VOLTAGE INPUT ACI: ANALOG CURRENT INPUT Frame Sizes A, B, and C March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 699 NEW! MOTOR CONTROLS HONEYWELL VARIABLE FREQUENCY DRIVES CORE VFD WITH BYPASS WIRING (continued) 3-PHASE POWER IS PROVIDED +1/DC+ FRAME E R r S s FUSE/NO FUSE BREAKER R(L1) NFB S(L2) T(L3) T(L3) COM +24V +24V FWD REV MI1 MI2 MI3 MI4 MI5 MI6 MI7 MI8 FWD/STOP REV/STOP PRESET SPD 1 PRESET SPD 2 PRESET SPD 3 PRESET SPD 4 EXT FAULT FAULT RESET NA NA MOTOR CONTROLS DIGITAL SIGNAL COMMON TERMINAL WHILE USING INTERNAL POWER TO RUN SINK MODE POWER REMOVAL SAFETY FUNCTION FOR EMERGENCY STOP DIGITAL SIGNAL COMMON TERMINAL +10V/20mA 3 5KΩ 2 1 0-20mA/0~10V ANALOG SIGNAL COMMON TERMINAL CONTROL TERMINALS RA1 (RELAY OUT 1): RUN RA2 (RELAY OUT 2): FAULT RA3 (RELAY OUT 3): READY DCM S1 MULTI-FUNCTION OUTPUT TERMINALS RA1 RB1 30VDC/6A RA2 250VAC/5A RC2 RA3 RC3 MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 30VDC/5A MODBUS RS-485 SG+ PIN 1~2, 7, 8: RESERVED SGPIN 3, 6: GND PIN 4: SGPIN 5: SG+ AFM1 ACI ACM AVI2 ACM AFM2 8 1 8 1 30VDC/5A MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A SCM AVI1 250VAC/6A RC1 +10V 0~10V/0~20mA 0~+10V MAIN CIRCUIT (POWER) TERMINALS IM 3~ V(T2) W(T3) DCM FACTORY SETTING: PNP SOURCE 12 MOTOR R(L1) S(L2) FACTORY SETTING -/DC+ U(T1) ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA ANALOG SIGNAL COMMON TERMINAL ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA OPTION SLOT 1 COMMUNICATION EXTENSION CARD OPTION SLOT 3 I/O & RELAY EXTENSION CARD SHIELDED LEADS & CABLES MI: MULTIFUNCTION INPUT AVI: ANALOG VOLTAGE INPUT ACI: ANALOG CURRENT INPUT Frame Sizes D and E 700 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS HONEYWELL VARIABLE FREQUENCY DRIVES CORE VFD WITH BYPASS WIRING (continued) BC-3 L1 L2 L3 HVFDSB3 L1 L2 L3 U V W Main Disconnect Three bypass contactors shown (BC-1, BC-2, BC-3). BC-3 not supplied in a two contactor bypass BC-1 M BC-2 Transformer To factory wired bypass controls (switches, coils, etc.) Note: Typical wiring shown. Refer to product installation manual for electrical wiring connections and requirements. ORDERING INFORMATION March 2014 DESCRIPTION CORE VFD W/BYPASS/208V/1 HP/NEMA 1 CORE VFD W/BYPASS/208V/2HP/NEMA 1/FRA CORE VFD W/BYPASS/208V/3HP/NEMA 1/FRA CORE VFD W/BYPASS/208V/5HP/NEMA 1/FRA CORE VFD W/BYPASS/208V/7.5HP/NEMA 1/FRA CORE VFD W/BYPASS/208V/10HP/NEMA 1/FRB CORE VFD W/BYPASS/208V/15HP/NEMA 1/FRB CORE VFD W/BYPASS/208V/20HP/NEMA 1/FRB CORE VFD W/BYPASS/208V/25HP/NEMA 1/FRC CORE VFD W/BYPASS/208V/30HP/NEMA 1/FRC CORE VFD W/BYPASS/208V/40HP/NEMA 1/FRC CORE VFD W/BYPASS/208V/50HP/NEMA 1/FRD CORE VFD W/BYPASS/208V/60HP/NEMA 1/FRD CORE VFD W/BYPASS/208V/75HP/NEMA 1/FRE CORE VFD W/BYPASS/208V/100HP/NEMA 1/FRE CORE VFD W/BYPASS/208V/125HP/NEMA 1/FRE CORE VFD W/BYPASS/230V/1HP/NEMA 1/FRA CORE VFD W/BYPASS/230V/2HP/NEMA 1/FRA CORE VFD W/BYPASS/230V/3HP/NEMA 1/FRA CORE VFD W/BYPASS/230V/5HP/NEMA 1/FRA CORE VFD W/BYPASS/230V/7.5HP/NEMA 1/FRA CORE VFD W/BYPASS/230V/10HP/NEMA 1/FRB CORE VFD W/BYPASS/230V/15HP/NEMA 1/FRB CORE VFD W/BYPASS/230V/20HP/NEMA 1/FRB MODEL HCRBB0250C1300T HCRBB0300C1300T HCRBB0400C1300T HCRBB0500D1300T HCRBB0600D1300T HCRBB0750E1300T HCRBB1000E1300T HCRBB1250E1300T HCRBC0010A1300T HCRBC0020A1300T HCRBC0030A1300T HCRBC0050A1300T HCRBC0075A1300T HCRBC0100A1300T HCRBC0150B1300T HCRBC0200B1300T HCRBC0250B1300T HCRBC0300C1300T HCRBC0400C1300T HCRBC0500C1300T HCRBC0600D1300T HCRBC0750D1300T HCRBC1000D1300T HCRBC1250D1300T WE MAKE IT EASY. DESCRIPTION CORE VFD W/BYPASS/230V/25HP/NEMA 1/FRC CORE VFD W/BYPASS/230V/30HP/NEMA 1/FRC CORE VFD W/BYPASS/230V/40HP/NEMA 1/FRC CORE VFD W/BYPASS/230V/50HP/NEMA 1/FRD CORE VFD W/BYPASS/230V/60HP/NEMA 1/FRD CORE VFD W/BYPASS/230V/75HP/NEMA 1/FRE CORE VFD W/BYPASS/230V/100HP/NEMA 1/FRE CORE VFD W/BYPASS/230V/125HP/NEMA 1/FRE CORE VFD W/BYPASS/460V/1HP/NEMA 1/FRA CORE VFD W/BYPASS/460V/2HP/NEMA 1/FRA CORE VFD W/BYPASS/460V/3HP/NEMA 1/FRA CORE VFD W/BYPASS/460V/5HP/NEMA 1/FRA CORE VFD W/BYPASS/460V/7.5HP/NEMA 1/FRA CORE VFD W/BYPASS/460V/10HP/NEMA 1/FRA CORE VFD W/BYPASS/460V/15HP/NEMA 1/FRB CORE VFD W/BYPASS/460V/20HP/NEMA 1/FRB CORE VFD W/BYPASS/460V/25HP/NEMA 1/FRB CORE VFD W/BYPASS/460V/30HP/NEMA 1/FRC CORE VFD W/BYPASS/460V/40HP/NEMA 1/FRC CORE VFD W/BYPASS/460V/50HP/NEMA 1/FRC CORE VFD W/BYPASS/460V/60HP/NEMA 1/FRD CORE VFD W/BYPASS/460V/75HP/NEMA 1/FRD CORE VFD W/BYPASS/460V/100HP/NEMA 1/FRD CORE VFD W/BYPASS/460V/125HP/NEMA 1/FRD kele.com 888-397-5353 USA 12 MOTOR CONTROLS MODEL HCRBA0010A1300T HCRBA0020A1300T HCRBA0030A1300T HCRBA0050A1300T HCRBA0075A1300T HCRBA0100B1300T HCRBA0150B1300T HCRBA0200B1300T HCRBA0250C1300T HCRBA0300C1300T HCRBA0400C1300T HCRBA0500D1300T HCRBA0600D1300T HCRBA0750E1300T HCRBA1000E1300T HCRBA1250E1300T HCRBB0010A1300T HCRBB0020A1300T HCRBB0030A1300T HCRBB0050A1300T HCRBB0075A1300T HCRBB0100B1300T HCRBB0150B1300T HCRBB0200B1300T 701 NEW! MOTOR CONTROLS HONEYWELL COMPACT VARIABLE FREQUENCY DRIVE SMARTDRIVE COMPACT VFD DESCRIPTION This compact VFD is a true micro drive, which saves space in the equipment cabinet and makes installation easy. The SmartDrive architecture allows for ease and speed in drive configuration. The intuitive user interface makes commissioning a breeze. The SmartDrive Compact VFD provides a standard PI Controller. Choose options to fit any application. Interface type, filter, enclosure, inputs, and outputs are available in a wide array of combinations. For wall mounting, a frame kit is recommended. Frame kits are not necessary for installation inside a panel. FEATURES • Small, compact micro drive design • PI controller standard • No main power supply required for programming • Intuitive user interface • DIN rail or screw mounting • Flexible options include inputs, outputs, field bus, and filtering • Application interface "touch wheel" makes programming easy CONTROL I/O SPECIFICATIONS Supply Voltage MOTOR CONTROLS 12 Motor Rating Acceleration Time Deceleration Time Frequency Range Digital Switch Inputs Analog Inputs Digital Outputs Analog Output Relay Outputs 208 to 230 VAC, 1 phase input - 3 phase output 380 to 480 VAC, 3 phase input/ output 0.25 - 7.5 hp 0.1- 3000 seconds 0.1 - 3000 seconds 30 - 320 Hz 6; 0 - 30 VDC programmable 2; (1) 0-10 VDC, (1) 0-20 mA or 4-20 mA 1 Open Collector, max. load 48V/ 50mA 1, 0-20 mA or 4-20 mA, RL=500Ω 2; (1) SPST N.O. (1) SPDT 250 VAC/2A, 250 VDC/0.4A Filter Type RFI Communication Protocol RS485 (Modbus protocol), Serial Operating Humidity 0 to 90% RH (non-condensing) Operating Temperature 14° to 122°F (-10° to 50°C) Frame Size MI1, MI2, MI3 Dimensions Frame sizes MI1 6.1"H x 2.6"W x 3.9"D (15.5 x 6.6 x 9.9 cm) MI2 7.7"H x 3.5"W x 4.0"D (19.6 x 8.9 x 10.2 cm) MI3 10.3"D x3.9"W x 4.3"D (26.2 x 9.9 x 10.9 cm) Weights MI1 1.20 lb (0.55 kg) MI2 1.50 lb (0.65 kg) MI3 2.18 lb (0.99 kg) Approvals CE, UL, cUL FILE #E190898 Warranty 3 years 702 API FULL Signal Terminal 1 +10Vre Ref. voltage out Analog signal in 1 2 AI1 888-397-5353 USA kele.com mA 3 6 GND 24Vout I/O signal ground 24V output for DI's 7 8 GND DI1 I/O signal ground Digital input 1 9 10 A B 4 DI2 Digital input 2 DI3 Digital input 3 A B AI2 RS485 signal A RS485 signal B Analog signal in 2 5 13 14 15 16 18 GND GND DI4 I/O signal ground I/O signal ground Digital input 4 DI5 Digital input 5 DI6 Digital input 6 AO 20 DO 22 RO 11 23 RO 12 24 RO 21 25 RO 22 26 RO 23 Digital signal out Relay out 1 Factory preset Freq. reference P) Description Maximum load 10 mA 0 - +10 V Ri = 200 kΩ (min) ±20%, max. load 50 mA Start forward P) Start reverse P) 0 - +30 V Ri = 12 kΩ min Preset speed B0 P) FB Communication FB Communication PI actual value P) 0(4) - 20 mA, Ri = 200Ω Preset speed B1P) 0 - +30 V Ri = 12 kΩ (min) Fault reset P) Disable PI contr. P) Output frequency P) Active = READY P) Active = RUN P) Relay out 2 Active = FAULT P) 0(4) - 20 mA, RL = 500Ω Open collector, max. load 48V/50mA Max. switching load: 250 VAC/2A or 250 VDC/ 0.4A Max. switching load: 250 VAC/2A or 250 VDC/ 0.4A P) = Programmable function, see parameter lists and descriptions in installation manual. Note: NEMA 1 frame kits include the top protection from vertically dripping water with additional physical contact protection over the wiring terminals. Recommended for nonenclosed VFD mounting. WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS HONEYWELL COMPACT VARIABLE FREQUENCY DRIVE SMARTDRIVE COMPACT VFD ORDERING INFORMATION Limited IO Model Supply Voltage Current Rating Horsepower EMC Frame Size HVFDCD1B0003F00 HVFDCD1B0003L00 208 to 230 VAC, 1 phase input - 3 phase output 1.7A 0.25 NO MI1 HVFDCD1B0003F01 HVFDCD1B0003L01 208 to 230 VAC, 1 phase input - 3 phase output 1.7A 0.25 YES MI1 HVFDCD1B0005F00 HVFDCD1B0005L00 208 to 230 VAC, 1 phase input - 3 phase output 2.4A 0.5 NO MI1 HVFDCD1B0005F01 HVFDCD1B0005L01 208 to 230 VAC, 1 phase input - 3 phase output 2.4A 0.5 YES MI1 HVFDCD1B0007F00 HVFDCD1B0007L00 208 to 230 VAC, 1 phase input - 3 phase output 2.8A 0.75 NO MI1 HVFDCD1B0007F01 HVFDCD1B0007L01 208 to 230 VAC, 1 phase input - 3 phase output 2.8A 0.75 YES MI1 HVFDCD1B0010F00 HVFDCD1B0010L00 208 to 230 VAC, 1 phase input - 3 phase output 3.7A 1 NO MI1 HVFDCD1B0010F01 HVFDCD1B0010L01 208 to 230 VAC, 1 phase input - 3 phase output 3.7A 1 YES MI1 HVFDCD1B0015F00 HVFDCD1B0015L00 208 to 230 VAC, 1 phase input - 3 phase output 4.8A 1.5 NO MI2 HVFDCD1B0015F01 HVFDCD1B0015L01 208 to 230 VAC, 1 phase input - 3 phase output 4.8A 1.5 YES MI2 HVFDCD1B0020F00 HVFDCD1B0020L00 208 to 230 VAC, 1 phase input - 3 phase output 7.0A 2 NO MI2 HVFDCD1B0020F01 HVFDCD1B0020L01 208 to 230 VAC, 1 phase input - 3 phase output 7.0A 2 YES MI2 HVFDCD1B0030F00 HVFDCD1B0030L00 208 to 230 VAC, 1 phase input - 3 phase output 11.0A 3 NO MI3 HVFDCD1B0030F01 HVFDCD1B0030L01 208 to 230 VAC, 1 phase input - 3 phase output 11.0A 3 YES MI3 HVFDCD3C0005F00 HVFDCD3C0005L00 380 to 480 VAC, 3 phase input/ output 1.3A 0.5 NO MI1 HVFDCD3C0005F01 HVFDCD3C0005L01 380 to 480 VAC, 3 phase input/ output 1.3A 0.5 YES MI1 HVFDCD3C0007F00 HVFDCD3C0007L00 380 to 480 VAC, 3 phase input/ output 1.9A 0.75 NO MI1 HVFDCD3C0007F01 HVFDCD3C0007L01 380 to 480 VAC, 3 phase input/ output 1.9A 0.75 YES MI1 HVFDCD3C0010F00 HVFDCD3C0010L00 380 to 480 VAC, 3 phase input/ output 2.4A 1 NO MI1 HVFDCD3C0010F01 HVFDCD3C0010L01 380 to 480 VAC, 3 phase input/ output 2.4A 1 YES MI1 HVFDCD3C0015F00 HVFDCD3C0015L00 380 to 480 VAC, 3 phase input/ output 3.3A 1.5 NO MI1 HVFDCD3C0015F01 HVFDCD3C0015L01 380 to 480 VAC, 3 phase input/ output 3.3A 1.5 YES MI1 HVFDCD3C0020F00 HVFDCD3C0020L00 380 to 480 VAC, 3 phase input/ output 4.3A 2 NO MI2 HVFDCD3C0020F01 HVFDCD3C0020L01 380 to 480 VAC, 3 phase input/ output 4.3A 2 YES MI2 HVFDCD3C0030F00 HVFDCD3C0030L00 380 to 480 VAC, 3 phase input/ output 5.6A 3 NO MI2 HVFDCD3C0030F01 HVFDCD3C0030L01 380 to 480 VAC, 3 phase input/ output 5.6A 3 YES MI2 HVFDCD3C0040F00 HVFDCD3C0040L00 380 to 480 VAC, 3 phase input/ output 7.6A 4 NO MI3 HVFDCD3C0040F01 HVFDCD3C0040L01 460 to 480 VAC, 3 phase input/ output 7.6A 4 YES MI3 HVFDCD3C0050F00 HVFDCD3C0050L00 460 to 480 VAC, 3 phase input/ output 9.0A 5 NO MI3 HVFDCD3C0050F01 HVFDCD3C0050L01 460 to 480 VAC, 3 phase input/ output 9.0A 5 YES MI3 HVFDCD3C0075F00 HVFDCD3C0075L00 460 to 480 VAC, 3 phase input/ output 12.0A 7.5 NO MI3 HVFDCD3C0075F01 HVFDCD3C0075L01 460 to 480 VAC, 3 phase input/ output 12.0A 7.5 YES MI3 March 2014 12 MOTOR CONTROLS Full IO Model ACCESSORIES HVFDCABLE HVFDCDMCA HVFDCDMCAKIT HVFDCDNEMA1FR1 HVFDCDNEMA1FR2 HVFDCDNEMA1FR3 Commissioning cable and USB adaptor VFD commissioning device Commisioning kit Enclosure upgrade Nema 1 kit frame size1 Enclosure upgrade Nema 1 kit frame size2 Enclosure upgrade Nema 1 kit frame size3 WE MAKE IT EASY. kele.com 888-397-5353 USA 703 NEW! MOTOR CONTROLS HONEYWELL ALL PURPOSE VARIABLE FREQUENCY DRIVES SMARTVFD HVAC DESCRIPTION SmartVFD HVAC drives are all-purpose, and can handle both constant-torque and variable-torque loads. The firmware includes special features that make start-up and commissioning of HVAC applications especially easy. Application-specific startup wizards for pumps and fans, combined with the simple and intuitive user interface, make the SmartVFD a pleasure rather than a chore. Integration is a snap with the SmartVFD. It includes both Ethernet and RS485 connections, and will talk BACnet, Modbus, and JCI N2. Take the complexity out of drive selection, installation, and startup - choose SmartVFD for your HVAC projects and start saving time, money, and manpower as well as energy. FEATURES • • • • • • • MOTOR CONTROLS 12 Intuitive commissioning High resolution graphic interface User manual included in firmware Simple start-up wizard - pump or fan Fire mode 2 PID controllers Real-time clock STANDARD I/O BOARD SPECIFICATIONS Supply Voltage Model specific, 3 phase, 60 Hz, 380-480 VAC or 200-240 VAC Motor Rating 0.75 to 250 Hp Frequency Range 0-320 Hz Acceleration Time 0.1 - 3000 seconds Deceleration Time 0.1 - 3000 seconds Digital Inputs 6 logical, 24 VDC= on, 0 VDC= off, all configurable Analog Input 2; 0-10V or 4-20 mA voltage input impedance 200Ω k current impedance 250Ω Digital Output Open collector, max. load 48V/ 50 mA Analog Output 1; 0-10 VDC or 4-20 mA programmable 500Ω maximum load Relay Outputs 2; SPDT 8A at 24 VDC or 250 VAC 0.4A at 125 VDC minimum load 10mA at 5 VAC/VDC Filter Type 5% DC choke Class 2 GMC/ RFI EMC Complies with EN50082-1, -2 EN61800-3 Communication Protocol RS485 JCI N2, MODBUS, BACnet MS/TP Ethernet BACnet/ IP, Modbus/TCP Operating Humidity 0 to 95% RH (non-condensing) Operating Temperature 14° to 104°F (-10° to 40°C) Approvals UL Listed File E190898 CE RoHS Eco Friendly Yes Warranty 3 years 704 888-397-5353 USA kele.com Terminal Signal 1 Reference output +10 VDC, +3%; Maximum current 10 mA 2 Analog input, voltage or current Analog input channel 1; Short-circuited protected 0- +10VDC (Ri = 200 kΩ) 4-20 mA (Ri = 250 Ω) Resolution 0.1%, accuracy ±1% Selection V/mA with dip-switches 3 Analog input common (current) Differential input if not connected to ground; Allows ±20V differential mode voltage to GND 4 Analog input voltage or current Analog input channel 2; Short-circuited protected Default: 4-20 mA (Ri =250 Ω) 0-10 VDC (Ri = 200kΩ) Resolution 0.1%, accuracy ±1% Selection V/mA with dip-switches 5 Analog input common (current) Differential input if not connected to ground; Allows 20V differential mode voltage to GND 6 +24 VDC, ±10%, max volt. ripple < 100mVrms; max. 250mA 24VDC aux. voltage Dimensioning: max. 1000mA/control unit. Short-circuit protected 7 I/O ground 8 Digital input 1 9 Digital input 2 10 Digital input 3 11 Common A for DIN1-DIN6 12 Technical information Ground for reference and controls (connected internally to frame earth through 1MΩ) Positive or negative logic Ri = min. 5kΩ 0...5VDC = “0” 15…30VDC = “1” Digital inputs can be disconnected from ground +24 VDC, ±10%, max volt. ripple < 100mVrms; max. 250mA 24 VDC aux. voltage Dimensioning: max. 1000mA/control unit. Short-circuit protected 13 I/O ground 14 Digital input 4 15 Digital input 5 16 Digital input 6 17 Common A for DIN1-DIN6 18 Analog signal (+output) 19 Analog output common 30 24 VDC auxiliary input voltage A RS485 B RS485 Ground for reference and controls (connected internally to frame earth through 1MΩ) Positive or negative logic Ri = min. 5kΩ 0...5VDC = “0” 15…30VDC = “1” Digital inputs can be isolated from ground. Analog output channel 1, selection 0 -20mA, load <500Ω Default: 0-20 mA/0-10 VDC Resolution 0.1%, accuracy ±2% Selection V/mA with dip-switches Short-circuited protected. Can be used as external power backup for the control unit Differential receiver/transmitter Set bus termination with dip switches WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS HONEYWELL ALL PURPOSE VARIABLE FREQUENCY DRIVES SMARTVFD HVAC RELAY BOARD TECHNICAL INFORMATION Relay board with two change-over contact (SPDT) relays and one relay Relay with normally-open (NO or SPST) board contact. 5.5 mm isolation between channels. 21 22 23 24 25 26 28 29 RELAY CONNECTIONS From Standard I/O board From term. #12 Relay Board From term. #13 RUN Terminal 21 RO1/1 Signal Relay output 1 22 RO1/2 23 RO1/3 Switching capacity 2 4VDC/8A 250 VAC/8A Relay Output 1* 125 VDC/0.4A Min.switching load 5V/10mA 24 RO2/1 Relay output 2 25 RO2/2 26 RO2/3 Switching capacity 24 VDC/8A 250 VAC/8A Relay Output 2* 125 VDC/0.4A Min.switching load 5V/10mA 28 TI1+ 29 TI1- Thermistor input Thermistor Rtrip = 4.7 kΩ (PTC); Input Measuring voltage 3.5V * If 230VAC is used as control voltage from the output relays, the control circuitry must be powered with a separate isolation transformer to limit short circuit current and ovrvoltage spikes. This is to prevent welding on the relay contacts. Refer to standard EN 60204-1, section 7.2.9 12 DIMENSIONS AND WEIGHTS 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 March 2014 208/ 230 VAC 460 VAC Enclosure NEMA type Width in. (cm) Height in. (cm) Depth in. (cm) Weight lb (kg) 0.75-4 HP 0.75-4 HP 0.75-4 HP 5-10 Hp 5-10 Hp 5-10 Hp 15-20 Hp 15-20 Hp 15-20 Hp 25-40 Hp 25-40 Hp 25-40 Hp 50-75 Hp 50-75 Hp 50-75 Hp 100-125 Hp 100-125 Hp 1.5-7.5 HP 1.5-7.5 HP 1.5-7.5 HP 10-20 Hp 10-20 Hp 10-20 Hp 25-40 Hp 25-40 Hp 25-40 Hp 50-75 Hp 50-75 Hp 50-75 Hp 100-150 Hp 100-150 Hp 100-150 Hp 200-250 Hp 200-250 Hp 1 12 3 1 12 3 1 12 3 1 12 3 1 12 3 1 12 5 (12.7) 5 (12.7) 20.5 (52.07) 5.7 (14.48) 5.7 (14.48) 20.5 (52.07) 7.7 (19.56) 7.7 (19.56) 28.5 (72.39) 9.3 (23.62) 9.3 (23.62) 28.8 (73.15) 11.4 (28.96) 11.4 (28.96) 11.4 (28.96) 18.9 (48.00) 18.9 (48.00) 12.9 (32.77) 12.9 (32.77) 20 (50.8) 16.5 (41.91) 16.5 (41.91) 24 (60.96) 21.9 (55.63) 21.9 (55.63) 36 (88.9) 25.4 (64.51) 25.4 (64.51) 48 (121.92) 38 (96.52) 38 (96.52) 38 (96.52) 45.3 (115.06) 45.3 (115.06) 7.5 (19.05) 7.5 (19.05) 10 (25.4) 8.4 (21.34) 8.4 (21.34) 10 (25.4) 9 (22.86) 9 (22.86) 10 (25.4) 10.2 (25.91) 10.2 (25.91) 12 (30.48) 13.5 (34.29) 13.5 (34.29) 13.5 (34.29) 14.4 (36.58) 14.4 (36.58) 13.0 (5.9) 13.0 (5.9) 13.0 (5.9) 22.0 (10.0) 22.0 (10.0) 22.0 (10.0) 44.0 (20.0) 44.0 (20.0) 44.0 (20.0) 83.0 (37.7) 83.0 (37.7) 83.0 (37.7) 154.0 (70.0) 154.0 (70.0) 154.0 (70.0) 238.0 (108.2) 238.0 (108.2) WE MAKE IT EASY. kele.com 888-397-5353 USA MOTOR CONTROLS Frame 705 NEW! MOTOR CONTROLS HONEYWELL ALL PURPOSE VARIABLE FREQUENCY DRIVES SMARTVFD HVAC ORDERING INFORMATION HP MOTOR CONTROLS 12 Amps 460 VAC 3.4 1.5 4.8 2 5.6 3 8 4 9.6 5 12 7.5 16 10 23 15 31 20 38 25 46 30 61 40 72 50 87 60 105 75 140 100 170 125 205 150 261 200 310 250 208/ 230 VAC 3.7 0.75 4.8 1 6.6 1.5 8 2 11 3 18 5 24 7.5 31 10 48 15 62 20 75 25 88 30 105 40 140 50 170 60 205 75 261 100 310 125 Frame NEMA 1 4 HVFDSD3C0015G100 4 HVFDSD3C0020G100 4 HVFDSD3C0030G100 4 HVFDSD3C0040G100 4 4 NEMA 12 NEMA3R HVFDSD3C0015G200 HVFDSD3C0015G300 HVFDSD3C0020G200 HVFDSD3C0020G300 HVFDSD3C0030G200 HVFDSD3C0030G300 HVFDSD3C0040G200 HVFDSD3C0040G300 HVFDSD3C0050G100 HVFDSD3C0050G200 HVFDSD3C0050G300 HVFDSD3C0075G100 HVFDSD3C0075G200 HVFDSD3C0075G300 5 HVFDSD3C0100G100 HVFDSD3C0100G200 HVFDSD3C0100G300 5 HVFDSD3C0150G100 HVFDSD3C0150G200 HVFDSD3C0150G300 5 HVFDSD3C0200G100 HVFDSD3C0200G200 HVFDSD3C0200G300 6 HVFDSD3C0250G100 HVFDSD3C0250G200 HVFDSD3C0250G300 6 HVFDSD3C0300G100 HVFDSD3C0300G200 HVFDSD3C0300G300 6 HVFDSD3C0400G100 HVFDSD3C0400G200 HVFDSD3C0400G300 7 HVFDSD3C0500G100 HVFDSD3C0500G200 HVFDSD3C0500G300 7 HVFDSD3C0600G100 HVFDSD3C0600G200 HVFDSD3C0600G300 7 HVFDSD3C0750G100 HVFDSD3C0750G200 HVFDSD3C0750G300 8 HVFDSD3C1000G100 HVFDSD3C1000G200 HVFDSD3C1000G300 8 HVFDSD3C1250G100 HVFDSD3C1250G200 HVFDSD3C1250G300 8 HVFDSD3C1500G100 HVFDSD3C1500G200 HVFDSD3C1500G300 9 HVFDSD3C2000G100 HVFDSD3C2000G200 - 9 HVFDSD3C2500G100 HVFDSD3C2500G200 - 4 HVFDSD3A0007G100 HVFDSD3A0007G200 HVFDSD3A0007G300 4 HVFDSD3A0010G100 HVFDSD3A0010G200 HVFDSD3A0010G300 4 HVFDSD3A0015G100 HVFDSD3A0015G200 HVFDSD3A0015G300 4 HVFDSD3A0020G100 HVFDSD3A0020G200 HVFDSD3A0020G300 4 HVFDSD3A0030G100 HVFDSD3A0030G200 HVFDSD3A0030G300 5 HVFDSD3A0050G100 HVFDSD3A0050G200 HVFDSD3A0050G300 5 HVFDSD3A0075G100 HVFDSD3A0075G200 HVFDSD3A0075G300 5 HVFDSD3A0100G100 HVFDSD3A0100G200 HVFDSD3A0100G300 6 HVFDSD3A0150G100 HVFDSD3A0150G200 HVFDSD3A0150G300 6 HVFDSD3A0200G100 HVFDSD3A0200G200 HVFDSD3A0200G300 7 HVFDSD3A0250G100 HVFDSD3A0250G200 HVFDSD3A0250G300 7 HVFDSD3A0300G100 HVFDSD3A0300G200 HVFDSD3A0300G300 7 HVFDSD3A0400G100 HVFDSD3A0400G200 HVFDSD3A0400G300 8 HVFDSD3A0500G100 HVFDSD3A0500G200 HVFDSD3A0500G300 8 HVFDSD3A0600G100 HVFDSD3A0600G200 HVFDSD3A0600G300 8 HVFDSD3A0750G100 HVFDSD3A0750G200 HVFDSD3A0750G300 9 HVFDSD3A1000G100 HVFDSD3A1000G200 - 9 HVFDSD3A1250G100 HVFDSD3A1250G200 - Drives are typically sized to match the horsepower rating of the motor, which will be accurate 95 percent of the time. For greatest accuracy, drives should be sized based upon the Full Load Amps or current draw of the motor. The VFD must have a slightly larger current rating maximum. 32006630-001 HVFDCABLE 706 888-397-5353 USA kele.com ACCESSORIES LON communication card Commissioning cable and USB adaptor WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS HONEYWELL VARIABLE FREQUENCY DRIVE WITH BYPASS SMARTVFD HVAC WITH BYPASS ASSEMBLY DESCRIPTION Honeywell’s integral bypass and disconnect system make applying the SmartVFD drive a snap. Available with a simple fused disconnect switch, a 2-contactor bypass assembly, or a 3-contactor bypass assembly, it simplifies installation. All the features of the SmartVFD are included -- a wide array of configurable inputs and outputs, and all the most popular network protocols, and the super easy startup wizards that speed commissioning. All drives feature Hand-Off-Auto operation as a is fully integrated keypad function. Make the SmartVFD choice for your variable speed drive needs. FEATURES • • • • • • • • • Disconnect, 2-, or 3-contactor bypass Fused disconnect Auto bypass available Available in NEMA 1, 12, or 3R enclosure types Compact size SmartVFD wizard for pump or fan control Intuitive commissioning High resolution graphic interface User manual built in to firmware SPECIFICATIONS Analog Output 208 VAC, 3 phase, 60 Hz 230 VAC, 3 phase, 60 Hz 480 VAC, 3 phase, 60Hz 1.0 to 250 Hp 0 - 320 Hz 0.1 - 3000 seconds 0.1 - 3000 seconds 6 factory preset 2; 0-10V or 4-20 mA programmable Open collector, max. load 48V / 50 mA 1; 4-20 mA Relay Outputs 2 each SPDT 8A at 24 VDC or 250 VAC 0.4A at 125 VDC Minimum load 10Ma at 5 VAC/VDC Filter Type 5% DC choke , and class 2 GMC/RFI EMC Complies with EN50082-1, -2 Communication Protocol RS485 BACnet MS/TP, N2, Modbus Ethernet BACnet/ IP, Modbus/TCP Operating Humidity 0 to 95% RH (non-condensing) Operating Temperature 14° to 104°F (-10° to 40°C) Approvals UL Listed File #E190898 cUL CE RoHS Eco Friendly Yes Warranty 3 years WIRING BC-3 L1 L2 L3 L1 L2 L3 Main Disconnect Three bypass contactors shown (BC-1, BC-2, BC-3). BC-3 not supplied in a two contactor bypass HVFDSB3 12 MOTOR CONTROLS Supply Voltage Motor Rating Frequency Range Acceleration Time Deceleration Time Digital Inputs Analog Input Digital Output BC-1 U V W M BC-2 Transformer To factory wired bypass controls (switches, coils, etc.) Note: Typical wiring shown. Refer to product installation manual for electrical wiring connections and requirements. March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 707 NEW! MOTOR CONTROLS HONEYWELL VARIABLE FREQUENCY DRIVE WITH BYPASS SMARTVFD HVAC WITH BYPASS ASSEMBLY DIMENSIONS - IN (CM) Horsepower and Voltage Frame 208/ 230 460 VAC Size VAC 4 5 6 7 0.75-4 Hp 5-10Hp NEMA 1 Configuration Width Height Disconnect 8.9 (22.6) 8.9 (22.6) 2-Contactor 8.9 (22.6) 8.9 (22.6) 3-Contactor, 3-Contactor w/ Auto- Bypass 8.9 (22.6) Disconnect 1.5-7.5 Hp 10-20 Hp 15-20Hp 25-40 Hp 25-40Hp 50-75 Hp 12 MOTOR CONTROLS 8 50-75 Hp 100-150 Hp NEMA 12 NEMA 3 R Depth Width Height Depth Width Height Depth 10.7 (26.2) 12.0 (29.4) 36.0 (88.2) 8.8 (21.6) 20.5 (50.2) 20.0 (49.0) 10.0 (24.5) 10.7 (26.2) 16.0 (39.2) 36.0 (88.2) 8.8 (21.6) 24.5 (60.0) 24.0 (58.8) 10.0 (24.5) 8.9 (22.6) 10.7 (26.2) 16.0 (39.2) 36.0 (88.2) 8.8 (21.6) 24.5 (60.0) 24.0 (58.8) 10.0 (24.5) 8.9 (22.6) 34.5 (84.5) 10.7 (26.2) 12.0 (29.4) 40.0 (98) 8.8 (21.6) 24.5 (60.0) 24.0 (58.8) 10.0 (24.5) 2-Contactor 8.9 (22.6) 34.5 (84.5) 10.7 (26.2) 16.0 (39.2) 44.0 (107.8) 8.8 (21.6) 28.5 (69.8) 30.0 (73.5) 10.0 (24.5) 3-Contactor, 3-Contactor w/ Auto- Bypass 8.9 (22.6) 41.5 (101.7) 10.7 (26.2) 16.0 (39.2) 44.0 (107.8) 8.8 (21.6) 28.5 (69.8) 30.0 (73.5) 10.0 (24.5) Disconnect 12.4 (30.4) 45.0 (110.3) 12.6 (30.9) 16.0 (39.2) 46.0 (112.7) 10.8 (26.5) 28.5 (69.8) 36.0 (88.2) 10.0 (24.5) 2-Contactor 12.4 (30.4) 45.0 (110.3) 12.6 (30.9) 20.0 (49.0) 54.0 (132.3) 10.8 (26.5) 34.5 (84.5) 36.0 (88.2) 10.0 (24.5) 3-Contactor, 3-Contactor w/ Auto- Bypass 12.4 (30.4) 55.0 (134.8) 12.6 (30.9) 20.0 (49.0) 54.0 (132.3) 10.8 (26.5) 34.5 (84.5) 36.0 (88.2) 10.0 (24.5) Disconnect 20.84 (51.1) 51.5 (126.2) 11.4 (27.9) 16.0 (39.2) 50.0 (122.5) 11.8 (28.9) 28.5 (69.8) 48.0 (117.6) 12.0 (29.4) 2-Contactor 20.84 (51.1) 51.5 (126.2) 11.4 (27.9) 24.0 (58.8) 64.0 (156.8) 13.6 (33.3) 40.4 (98.9) 48.0 (117.6) 12.0 (29.4) 3-Contactor, 3-Contactor w/ Auto- Bypass 20.84 (51.1) 59.0 (144.6) 11.4 (27.9) 24.0 (58.8) 64.0 (156.8) 13.6 (33.3) 40.4 (98.9) 48.0 (117.6) 12.0 (29.4) Disconnect 25.0 (61.3) 60.0 (147.0) 16.2 (39.7) 20.0 (49.0) 64.0 (156.8) 15.1 (36.9) 40.4 (98.9) 48.0 (117.6) 12.0 (29.4) 2-Contactor 25.0 (61.3) 60.0 (147.0) 16.2 (39.7) 56.0 (137.2) 48.0 (117.6) 15.1 (36.9) 40.4 (98.9) 60.0 (147.0) 12.0 (29.4) 3-Contactor, 3-Contactor w/ Auto- Bypass 25.0 (61.3) 70.0 (171.5) 16.2 (39.7) 56.0 (137.2) 48.0 (117.6) 15.1 (36.9) 40.4 (98.9) 60.0 (147.0) 12.0 (29.4) SMART VFD BYPASS CONFIGURATIONS Our five configurations make it easy for you to select the right bypass to complete your drive package. All bundles are available in NEMA 1, NEMA 12 and ventilated NEMA 3R HOA (HAND OFF AUTO). SmartVFD Disconnect Only • Adds a fused disconnect to the VFD. SmartVFD 2-Contactor Bypass Provides an economical means of bypassing the VFD. • Freeze/Fire/Smoke Interlock SmartVFD 3-Contactor Bypass Commission, service or replace the VFD without affecting the operation of the motor. • Fused Disconnect • Freeze/Fire/Smoke Interlock • VFD is isolated from power with motor running in BYPASS mode • TEST position powers the VFD without sending power to the motor 708 888-397-5353 USA kele.com SmartVFD 3-Contactor Bypass with Auto-Bypass The package adds the control capabilities below to the standard three contactor bypass. • Any VFD fault will automatically send the bypass to BYPASS mode • A contact closure sends the bypass to BYPASS mode • Dry contacts indicate when the bypass is in BYPASS mode, alerting the building management system WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS HONEYWELL VARIABLE FREQUENCY DRIVE WITH BYPASS SMARTVFD HVAC WITH BYPASS ASSEMBLY ORDERING INFORMATION HVFDSB3 Honeywell SmartVFD HVAC A 208 VAC - up to 75 Hp B 230 VAC - up to 75 Hp C 480 VAC - up to 150 Hp Motor Horsepower 0007 .75 Hp 208, 230 & 480 VAC 0010 1 Hp 208, 230 & 480 VAC 0015 1.5 Hp 208, 230 & 480 VAC 0020 2 Hp 208, 230 & 480 VAC 0030 3 Hp 208, 230 & 480 VAC 0040 4 Hp 208, 230 & 480 VAC 0050 5 Hp 208, 230 & 480 VAC 0075 7.5 Hp 208, 230 & 480 VAC 0100 10 Hp 208, 230 & 480 VAC 0150 15 Hp 208, 230 & 480 VAC 0200 20 Hp 208, 230 & 480 VAC 0250 25 Hp 208, 230 & 480 VAC 0300 30 Hp 208, 230 & 480 VAC 0400 40 Hp 208, 230 & 480 VAC 0500 50 Hp 208, 230 & 480 VAC 0600 60 Hp 208, 230 & 480 VAC 0750 75 Hp 208, 230 & 480 VAC 1000 100 Hp 480 VAC 1250 125 Hp 480 VAC 1500 150 Hp 480 VAC 12 User Interface Graphic User Interface MOTOR CONTROLS G Enclosure 1 NEMA 1 2 NEMA 12 3 NEMA 3R Options HVFDSB3 C 0400 32006630-001 HVFDCABLE March 2014 G 1 10 Disconnect only 20 Drive with 2 contractor BYPASS 30 Drive with 3 contactor BYPASS 31 Drive with 3 contactor BYPASS, w/ Fused disconnect and Auto-bypass 30 Example: HVDSB3C0400G130 480 VAC, 40 Hp, Smart VFD NEMA 1 with graphic keypad display, 3 contractor bypass ACCESSORIES PAGE LON communication card Commissioning cable and USB adaptor WE MAKE IT EASY. kele.com 888-397-5353 USA 709 NEW! MOTOR CONTROLS MOTOR CONTROL ACRONYMS, CALCULATIONS & CONVERSION FORMULAS IGBT = insulated gate bi-thermal thyristor AC = alternating current ANSI = American National Standards Institute LCI = load-commutated inverter ASD = adjustable speed drive NEMA = National Electrical Manufacturers Association BHP = brake horsepower CFM = cubic feet per minute MOTOR CONTROLS 12 IEEE = Institute of Electrical and Electronics Engineers NPV = net present value CSA = Canadian Standards Association PAM = pulse amplitude modulation CSI = current source inverter PLC = programmable logic controller DC = direct current PWM = pulse width modulated (inverter) DSP = digital signal processor SCR = silicon-controlled rectifier ECC = eddy current coupling SR = switched reluctance FPM = feet per minute THD = total harmonic distortion GPM = gallon per minute V = voltage GTO = gate turnoff (thyristor) VSI = variable source inverter HDF = harmonic distortion factor VVI = variable voltage inverter Calculating the Horsepower Requirement of a Load The mechanical load required by the driven equipment is known as the Brake Horsepower (BHP). The BHP value can be calculated by the following: BHP = T x N (required HP) 5,250 Where: HP = horsepower supplied by the motor T = Torque (lb-ft) force x radius N = base speed of motor (rpm) Once the machine BHP (speed times torque) requirement is determined, horsepower (HP) can be calculated: Rated motor HP = Motor Efficiency (%) / 100 = available HP If the calculated horsepower falls between standard available motor ratings, select the higher available horsepower rating. It is good practice to allow some margin when selecting the motor horsepower. 710 888-397-5353 USA kele.com CONVERSION FORMULAS/FACTORS Multiply By To Obtain Meters 3.281 Feet Meters 39.37 Inches Inches 0.025 Meters Feet 0.305 Meters Torque Newton-Meters 0.738 lb-ft lb-ft 1.356 Newton-Meters lb-in 0.083 lb-ft lb-ft 12.00 lb-in Rotation RPM 6.00 Degrees per second RPM 0.105 Radius per second Degrees per second 0.167 RPM Radius per second 9.549 RPM Power Watts 0.001 HP lb-ft per minute 0.000 HP HP 746 Watts HP 30300 lb-ft/min Temperature Degrees C = (Degrees F-32) x 5/9 Degrees F = (Degrees C x 9/5) + 32 Length WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! MOTOR CONTROLS GLOSSARY OF COMMON TERMS Alternating Current: The flow of electricity which changes direction on a regular continuous cycle reaching a maximum in one direction, decreasing to zero, then reversing to reach a maximum in the opposite direction. Air Gap: The space between the rotating and stationary part of an electric motor. Magnetic energy is transferred across this gap. Ambient: The air which surrounds a motor for air cooled machines. Ampere: A unit of current which is a measure of the rate of electron flow. It is often abbreviated as Amp. The unit of current flow is the amp. Breakdown Torque: The maximum torque that a motor can develop at rated voltage without stalling or an abrupt drop in speed. Brush: A current carrying material which is in contact with an armature or slip ring assembly to provide an electrical connection between rotating and stationary components of a motor. Capacitor: A device which can store electrical charge. In an AC circuit, a capacitor causes the voltage to lead the current. The unit of capacitance is the Farad. Commutator: An assembly which is mounted on the shaft of a DC motor to provide the switching functions between the armature coils and the power supply. Conductor: Any material which offers little resistance to the flow of electricity such as copper. Duty Cycle: The relationship between the operating time and the resting time of an electric motor. Eddy Current: Localized currents in electrical steels that are caused by alternating magnetic flux resulting in losses and heating. 12 Efficiency: The ratio of mechanical output to the electrical input power of a motor. Field: The term used to describe the stationary part of a DC machine. The field provides the magnetic flux which interacts with the armature. Flux: The magnetic field which is established around a current carrying conductor or a permanent magnet. Frequency: The rate at which alternating current reverses its direction of flow. The unit of frequency is either Hertz or cycles per second. MOTOR CONTROLS Electromotive Force (emf): A synonym for voltage usually used to describe induced or generated voltages in an electric circuit. Full Load Current: The current that a motor draws at rated voltage, frequency and load. Full Load Slip: The difference between the synchronous speed of a motor and full load speed. It is often expressed as a ratio of the synchronous speed to full load speed in percent. Full Load Speed: The speed of the motor at rated voltage, frequency and load. Full Load Torque: The torque that is necessary to produce rated horsepower at full load speed. Horsepower: A measurement of power used to rate electric motors. The unit of power rating in motors is either horsepower or kilowatts. One horsepower is equal to 746 watts. March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 711 NEW! MOTOR CONTROLS GLOSSARY OF COMMON TERMS Impedance: The total opposition a circuit offers to the flow of alternating current. It is the vector sum of resistance and reactance. Inductance: The property of an electrical circuit which opposes a change in current due to the magnetic field induced by that current. Inertia: Inertia is the resistance an object has to a change in its state of motion. It is determined by the weight of the object multiplied by the square of the radius of gyration (k). Rotating parts do not operate at the same speed, therefore calculating the inertia for each moving part allows rotating parts to be considered as a single unit working together. Line Voltage: The voltage supplied to the input terminals of an electric device. Magnetomotive Force (mmf): The magnetic energy supplied in the establishment of magnetic flux. It is analogous to the electromotive force in an electric circuit. Phase: A term used to describe the spatial relationship of windings in an electric motor or voltages and currents in an electric circuit. Power Factor: A measurement of the difference in phase between voltage and current in an electric circuit. Most electrical devices cause the current to lag the voltage because of inductance. The voltage leads the current in capacitive circuits. Reactance (inductive): The property of a magnetic circuit which causes the voltage to lag the current. 12 Resistance: The property of an electrical conductor which impedes the flow of electricity. The unit of resistance is the ohm. MOTOR CONTROLS Rotor: The rotating member of an electric motor. Service Factor: The service factor of an AC motor is a multiplier which when applied to the rated horsepower indicates the permissible loading which may be carried under the conditions specified for the service factor. Slip: The ratio between the synchronous speed and the operating speed of an induction motor, often expressed as a percent. Stator: The stationary part of an AC motor housing the steel laminations and the windings. Temperature Rise: The difference between the temperature of the windings of an operating motor and the ambient temperature. Torque: The turning force applied to a shaft, usually expressed as pound-feet (English) or Newton-meters (metric). Voltage: The standard unit of electromotive force which produces a flow of current in a conductor. The unit of electromotive force is the volt. Watt: A measurement of power in an electrical circuit which is equal to one joule of energy being expended in one second. 712 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014