Preview only show first 10 pages with watermark. For full document please download

Kestrel Range Polyester Enclosures

   EMBED


Share

Transcript

Kestrel Range Polyester Enclosures KE 1-12 Kestrel Range Polyester Enclosure The kestrel range of glass reinforced polyester enclosures available in seventeen sizes in black, grey, red + blue, provide a high quality maintenance free solution for intermediate electrical junctions. Where corrosion resistance, impact strength or ingress protection are key factors the kestrel range is highly recommended. Black - Kestrel Grey - Kestrel Blue - Kestrel Red - Kestrel "KE" range "POK range "BE" range "RE" range Specifications Material Surface resistance Finish Gasket Lid fixing Box mounting Equipment mounting Ingress protection Temperature range Impact resistance Toxicity Deluge Test: Factory options Assembly Earthing EMC POK, BE, RE, KE Type KE Type POK Type BE Type RE Sizes 1, 2, 3, 31 Sizes 32 Sizes 71, 91 All other sizes Sizes 1, 2, 3, 31, 32 All other sizes Sizes 1 + 2 Sizes 3, 31, 32 All other sizes All sizes All sizes Glassfibre reinforced polyester (GRP) >1 GΩ <1 GΩ Black, similar to RAL 9001 Grey, similar to RAL 7001 Blue, similar to RAL 5012 Red, similar to RAL 2002 Silicone rubber 4 x M4 captive stainless steel screws 6 x M4 captive stainless steel screws 6 x M6 captive stainless steel screws 4 x M6 captive stainless steel screws 4 x fixing holes for M4 screws 4 x fixing holes for M6 screws. Brass mounting studs for M3 screws Brass mounting studs for M4 screws Brass mounting studs for M6 screws IP68 to IEC 529 (EN 60529) (1.5 m / 1 hour) -40°C to +130 °C -20°C to +55°C (ambient) 7 Nm Halogens and cadmium free Spec. No. ATS01 (excluding size 71 and 91) Terminals and cable glands fitted to specification One piece or single brass continuity plate M6/M10 internal/external earth stud. The KE range can be treated to provide shielding against electromagnetic interference. Approvals T 48 KE (black) and POK (grey) Sizes: 1, 2, 4, 5, 51, 6, 7, 8, 9, 91, 10. Enclosure with terminals EEx'e' IIT6 to EN 50019 Certificate of Conformity KE: 94C.102.961 POK: 94C.102.962X Empty enclosure EEx'e' II to EN 50019 Component Certificate KE: 93C.102.959U POK: 93C.102.960U Other enclosures: Industrial applications Kestrel range Size 1 Size 2 Height Width Depth Weight Height Width Depth Weight A A = Top B = Bottom C = Left hand side D = Right hand side E = Base C E D B Black-Kestrel "KE" range Grey-Kestrel "POK" range Blue-Kestrel "BE" range Red-Kestrel "RE" range All dimensions in mm Ordering data Supplied with Black (GPR) Grey (GPR) Blue (GPR Red (GPR) 75 80 60 0.35 kg Type KE 1 POK 1 BE 1 RE 1 Guide to gland entries Max. glanding area dimensions through wall of enclosure. Gland sizes (mm) per side Brass glands with locknuts Gland sizes (P.G) per side Plastic glands with locknuts Accessories Mounting rail Sides A+B C+D 16 20 25 32 40 50 7 9 11 13.5 16 21 29 36 42 TS 15 TS 32 TS 35 U Y W Terminal selection guide Terminal selection guide for terminals of a specific type which can be mounted within these enclosures. Cat. No. 951021 127720 951073 951460 Size 50 x 32 29 x 27 75 110 60 0.40 kg Type KE 2 POK 2 BE 2 RE 2 Cat. No. 951022 127730 951074 951461 Size 80 x 32 29 x 27 Sides A+B C+D Side A + B 1 Side C + D Side A + B 2 Side C + D 2 2 1 1 1 1 4 3 2 2 1 1 Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 64 60 52 Vert. Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 94 90 82 Vert. Type (TH) mm Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. Type (TH) mm Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. 1x4 1x4 1 x 10 1x8 Approvals T EEx'e' IIT6 to EN 50019 Certificate of Conformity KE: 94C.102.961, POK: 94C.102.962X Component Certificate KE: 93C.102.959U, POK: 93C.102.960U EEx'e' IIT6 to EN 50019 Certificate of Conformity KE: 94C.102.961, POK: 94C.102.962X Component Certificate KE: 93C.102.959U, POK: 93C.102.960U 49 Kestrel range Size 3 Size 31 Height Width Depth Weight Height Width Depth Weight A A = Top B = Bottom C = Left hand side D = Right hand side E = Base C E D B Black-Kestrel "KE" range Grey-Kestrel "POK" range Blue-Kestrel "BE" range Red-Kestrel "RE" range All dimensions in mm Ordering data Supplied with Black (GPR) Grey (GPR) Blue (GPR Red (GPR) 75 160 60 497 kg Type KE 3 POK 3 BE 3 RE 3 Guide to gland entries Max. glanding area dimensions through wall of enclosure. Gland sizes (mm) per side Brass glands with locknuts Gland sizes (P.G) per side Plastic glands with locknuts Accessories Mounting rail Sides A+B C+D 16 20 25 32 40 50 7 9 11 13.5 16 21 29 36 42 TS 15 TS 32 TS 35 U Y W Terminal selection guide Terminal selection guide for terminals of a specific type which can be mounted within these enclosures. Cat. No. 951032 127740 951075 951462 Size 130 x 32 29 x 27 75 190 60 535 kg Type KE 31 POK 31 BE 31 RE 31 Cat. No. 951033 156540 951076 951463 Size 160 x 30 29 x 27 Sides A+B C+D Side A + B 4 Side C + D Side A + B 5 Side C + D 6 5 4 4 1 1 8 6 5 5 1 1 Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 145 139 131 Vert. Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 174 168 160 Vert. Type (TH) mm Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. Type (TH) mm Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. 1 x 20 1 x 16 1 x 26 1 x 21 Approvals EEx'e' Harzardous Area Certification Pending T 50 EEx'e' Harzardous Area Certification Pending Size 32 Size 4 Size 5 Height Width Depth Weight Height Width Depth Weight Height Width Depth Weight 75 230 60 580 gm Type KE 32 POK 32 BE 32 RE 32 Cat. No. 951034 951051 951077 951464 Size 2 x 91 x 35 29 x 27 Sides A+B C+D 120 125 90 0.68 kg Type KE 4 POK 4 BE 4 RE 4 Cat. No. 951023 127750 951078 951465 Size 88 x 54 60 x 46 Sides A+B C+D 120 220 95 1.06 kg Type KE 5 POK 5 BE 5 RE 5 Cat. No. 951024 127760 951079 951466 Size 182 x 58 60 x 52 Sides A+B C+D Side A + B 6 Side C + D Side A + B 5 2 1 1 Side C + D 2 1 1 Side A + B 12 7 4 3 Side C + D 3 2 1 10 8 6 4 1 1 9 6 4 3 2 2 1 6 3 2 1 1 1 1 20 14 12 7 6 4 3 6 4 3 2 2 1 1 Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 213 209 201 Vert. Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 105 98 90 Vert. - Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 200 193 185 Vert. - Type (TH) mm Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. Type (TH) mm Mounting rail TS 35 WDU 1.5 (5) WDU 2.5 (5) WDU 4 (6) Mounting rail TS 32 SAK 2.5 (6) SAK 4 (6.5) SAK 6N (8) Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. Type (TH) mm Mounting rail TS 35 WDU 1.5 (5) WDU 2.5 (5) WDU 4 (6) Mounting rail TS 32 SAK 2.5 (6) SAK 4 (6.5) SAK 6N (8) Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. 1 x 33 1 x 28 EEx'e' Harzardous Area Certification Pending EEx'e' IIT6 to EN 50019 Certificate of Conformity KE: 94C.102.961, POK: 94C.102.962X Component Certificate KE: 93C.102.959U, POK: 93C.102.960U 1 x 12 1 x 12 1 x 11 1 x 11 1 x 10 1x8 1 x 12 1 x 11 1 x 31 1 x 31 1 x 26 1 x 26 1 x 24 1 x 20 1 x 31 1 x 26 EEx'e' IIT6 to EN 50019 Certificate of Conformity KE: 94C.102.961, POK: 94C.102.962X Component Certificate KE: 93C.102.959U, POK: 93C.102.960U 51 Kestrel range Size 51 Size 6 Height Width Depth Weight Height Width Depth Weight A A = Top B = Bottom C = Left hand side D = Right hand side E = Base C E D B Black-Kestrel "KE" range Grey-Kestrel "POK" range Blue-Kestrel "BE" range Red-Kestrel "RE" range Ordering data Supplied with Black (GPR) Grey (GPR) Blue (GPR Red (GPR) 160 160 95 1.31 kg Type KE 51 POK 51 BE 51 RE 51 Guide to gland entries Max. glanding area dimensions through wall of enclosure. Gland sizes (mm) per side Brass glands with locknuts Gland sizes (P.G) per side Plastic glands with locknuts Accessories Mounting rail 16 20 25 32 40 50 7 9 11 13.5 16 21 29 36 42 TS 15 TS 32 TS 35 U Y W Terminal selection guide Terminal selection guide for terminals of a specific type which can be mounted within these enclosures. Sides A+B C+D Cat. No. 951025 156541 951080 951467 Size 114 x 60 84 x 54 Side A + B 7 3 2 2 15 9 8 5 3 3 1 160 260 95 1.71 kg Type KE 6 POK 6 BE 6 RE 6 Sides A+B C+D Cat. No. 951026 127770 951081 951468 Size 214 x 60 84 x 54 Side C + D 4 2 1 1 Side A + B 14 6 5 3 Side C + D 4 2 1 1 9 6 4 3 2 1 1 30 15 14 9 7 5 3 9 6 4 3 2 1 1 Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 139 132 124 Vert. - Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 239 232 224 Vert. - Type (TH) mm Mounting rail TS 35 WDU 1.5 (5) WDU 2.5 (5) WDU 4 (6) WDU 6 (8) Mounting rail TS 32 SAK 2.5 (6) SAK 4 (6.5) SAK 6N (8) SAK 10 (10) Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. Type (TH) mm Mounting rail TS 35 WDU 1.5 (5) WDU 2.5 (5) WDU 4 (6) WDU 6 (8) Mounting rail TS 32 SAK 2.5 (6) SAK 4 (6.5) SAK 6N (8) SAK 10 (10) Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. 1 1 1 1 x x x x 19 19 16 12 1 1 1 1 x x x x 16 15 12 10 1 x 19 1 x 16 Approvals T 52 EEx'e' IIT6 to EN 50019 Certificate of Conformity KE: 94C.102.961, POK: 94C.102.962X Component Certificate KE: 93C.102.959U, POK: 93C.102.960U EEx'e' IIT6 to EN 50019 Certificate of Conformity KE: 94C.102.961, POK: 94C.102.962X Component Certificate KE: 93C.102.959U, POK: 93C.102.960U 1 1 1 1 x x x x 39 39 32 24 1 1 1 1 x x x x 32 30 24 19 1 x 38 1 x 32 Size 7 Size 71 Size 8 Height Width Depth Weight Height Width Depth Weight Height Width Depth Weight 160 360 95 2.15 kg Type KE 7 POK 7 BE 7 RE 7 Sides A+B C+D Cat. No. 951027 127780 951082 951469 Size 314 x 60 84 x 55 Side A + B 20 9 7 5 35 22 20 15 11 8 5 160 560 95 3.713 kg Type KE 71 POK 71 BE 71 RE 71 Sides A+B C+D Cat. No. 951035 951052 951083 951470 Size 2 x (239 x 60) 84 x 54 Side C + D 4 2 1 1 Side A + B 28 16 10 8 9 6 4 3 2 1 1 46 32 32 20 18 12 8 250 255 125 2.65 kg Type KE 8 POK 8 BE 8 RE 8 Sides A+B C+D Cat. No. 951028 156542 951084 951471 Size 209 x 86 174 x 81 Side C + D 4 2 1 1 Side A + B 18 11 7 4 3 2 Side C + D 14 8 5 3 2 2 9 6 4 3 2 1 1 40 24 17 17 13 9 5 3 3 32 18 14 11 8 7 3 2 2 Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 339 332 324 Vert. - Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 539 532 524 Vert. - Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 234 227 219 Vert. - Type (TH) mm Mounting rail TS 35 WDU 1.5 (5) WDU 2.5 (5) WDU 4 (6) WDU 6 (8) Mounting rail TS 32 SAK 2.5 (6) SAK 4 (6.5) SAK 6N (8) SAK 10 (10) Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. Type (TH) mm Mounting rail TS 35 WDU 1.5 (5) WDU 2.5 (5) WDU 4 (6) WDU 6 (8) Mounting rail TS 32 SAK 2.5 (6) SAK 4 (6.5) SAK 6N (8) SAK 10 (10) Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. Type (TH) mm Mounting rail TS 35 WDU 1.5 (5) WDU 2.5 (5) WDU 4 (6) WDU 6 (8) Mounting rail TS 32 SAK 2.5 (6) SAK 4 (6.5) SAK 6N (8) SAK 10 (10) Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. EEx'e' IIT6 to EN 50019 Certificate of Conformity KE: 94C.102.961, POK: 94C.102.962X Component Certificate KE: 93C.102.959U, POK: 93C.102.960U 1 1 1 1 x x x x 58 58 49 37 1 1 1 1 x x x x 49 45 37 29 1 x 58 1 x 49 1 1 1 1 x x x x 98 98 82 62 1 1 1 1 x x x x 82 76 62 49 1 x 98 1 x 82 EEx'e' Harzardous Area Certification Pending 2 2 2 2 x x x x 38 38 32 24 2 2 2 2 x x x x 32 29 24 19 2 x 37 2 x 31 EEx'e' IIT6 to EN 50019 Certificate of Conformity KE: 94C.102.961, POK: 94C.102.962X Component Certificate KE: 93C.102.959U, POK: 93C.102.960U 53 Kestrel range Size 9 Size 91 Height Width Depth Weight Height Width Depth Weight A A = Top B = Bottom C = Left hand side D = Right hand side E = Base C E D B Black-Kestrel "KE" range Grey-Kestrel "POK" range Blue-Kestrel "BE" range Red-Kestrel "RE" range Ordering data Supplied with Black (GPR) Grey (GPR) Blue (GPR Red (GPR) 250 400 125 4.50 kg Type KE 9 POK 9 BE 9 RE 9 Guide to gland entries Max. glanding area dimensions through wall of enclosure. Gland sizes (mm) per side Brass glands with locknuts Gland sizes (P.G) per side Plastic glands with locknuts Accessories Mounting rail 16 20 25 32 40 50 7 9 11 13.5 16 21 29 36 42 TS 15 TS 32 TS 35 U Y W Terminal selection guide Terminal selection guide for terminals of a specific type which can be mounted within these enclosures. Sides A+B C+D Cat. No. 951029 156543 951085 951472 Size 354 x 86 174 x 81 Side A + B 32 18 14 7 5 4 64 39 36 32 22 17 8 6 5 250 600 125 5.83 kg Type KE 91 POK 91 BE 91 RE 91 Sides A+B C+D Cat. No. 951030 951047 951086 951473 Size 2 x (262 x 86) 172 x 81 Side C + D 14 8 5 3 2 2 Side A + B 46 26 20 10 6 6 Side C + D 14 8 5 3 2 2 32 18 14 11 8 7 3 2 2 96 60 46 38 28 22 10 8 6 32 18 14 11 8 7 3 2 2 Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 379 372 364 Vert. Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 577 570 562 Vert. Type (TH) mm Mounting rail TS 35 WDU 1.5 (5) WDU 2.5 (5) WDU 4 (6) WDU 6 (8) Mounting rail TS 32 SAK 2.5 (6) SAK 4 (6.5) SAK 6N (8) SAK 10 (10) Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. Type (TH) mm Mounting rail TS 35 WDU 1.5 (5) WDU 2.5 (5) WDU 4 (6) WDU 6 (8) Mounting rail TS 32 SAK 2.5 (6) SAK 4 (6.5) SAK 6N (8) SAK 10 (10) Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. 2 2 1 1 x x x x 67 67 56 42 2 2 2 2 x x x x 56 51 42 33 2 x 66 2 x 55 Approvals T 54 EEx'e' IIT6 to EN 50019 Certificate of Conformity KE: 94C.102.961, POK: 94C.102.962X Component Certificate KE: 93C.102.959U, POK: 93C.102.960U EEx'e' IIT6 to EN 50019 Certificate of Conformity KE: 94C.102.961, POK: 94C.102.962X Component Certificate KE: 93C.102.959U, POK: 93C.102.960U 2 x 108 2 x 108 1 x 90 1 x 67 2 2 2 2 x x x x 90 83 67 54 2 x 106 2 x 89 Size 10 Size 11 Size 12 Height Width Depth Weight Height Width Depth Weight Height Width Depth Weight 405 400 125 5.58 kg Type KE 10 POK 10 BE 10 RE 10 Sides A+B C+D Cat. No. 951031 156544 951087 951474 Size 354 x 86 329 x 81 Side A + B 32 18 14 7 5 4 64 39 36 32 22 17 8 6 5 250 255 165 3.92 kg Type KE 11 POK 11 BE 11 RE 11 Sides A+B C+D Cat. No. 951036 951053 951088 951475 Size 209 x 86 174 x 81 Side C + D 24 16 9 6 4 4 Side A + B 18 11 7 4 3 2 45 36 26 23 19 15 7 5 4 40 24 17 17 13 9 5 3 3 250 400 165 5.056 kg Type KE 12 POK 12 BE 12 RE 12 Sides A+B C+D Cat. No. 951037 951054 951089 951476 Size 354 x 86 174 x 81 Side C + D 14 8 5 3 2 2 Side A + B 32 18 14 7 5 4 Side C + D 14 8 5 3 2 2 32 18 14 11 8 7 3 2 2 64 39 36 32 22 17 8 6 5 32 18 14 11 8 7 3 2 2 Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 379 372 364 Vert. - Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 234 227 219 Vert. - Rail Overall length (mm) Fixing centres (mm) Assembly length (mm) between centres Horiz. 379 372 364 Vert. - Type (TH) mm Mounting rail TS 35 WDU 1.5 (5) WDU 2.5 (5) WDU 4 (6) WDU 6 (8) Mounting rail TS 32 SAK 2.5 (6) SAK 4 (6.5) SAK 6N (8) SAK 10 (10) Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. Type (TH) mm Mounting rail TS 35 WDU 1.5 (5) WDU 2.5 (5) WDU 4 (6) WDU 6 (8) Mounting rail TS 32 SAK 2.5 (6) SAK 4 (6.5) SAK 6N (8) SAK 10 (10) Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. Type (TH) mm Mounting rail TS 35 WDU 1.5 (5) WDU 2.5 (5) WDU 4 (6) WDU 6 (8) Mounting rail TS 32 SAK 2.5 (6) SAK 4 (6.5) SAK 6N (8) SAK 10 (10) Mounting rail TS 15 AKZ 2.5 (5) AKZ 4 (6) Horiz. Vert. EEx'e' IIT6 to EN 50019 Certificate of Conformity KE: 94C.102.961, POK: 94C.102.962X Component Certificate KE: 93C.102.95U, POK: 93C.102.960U 3 3 2 2 x x x x 67 67 56 42 3 3 3 3 x x x x 56 51 42 33 3 x 66 3 x 55 2 2 2 2 x x x x 38 38 32 24 2 2 2 2 x x x x 32 29 24 19 2 x 37 2 x 32 EEx'e' Harzardous Area Certification Pending 2 2 1 1 x x x x 67 67 56 42 2 2 2 2 x x x x 56 51 42 33 2 x 67 2 x 56 EEx'e' Harzardous Area Certification Pending 55 Accessories Mounting plates Mounting plates for the KE, POK, BE +RE range of enclosures manufactured from 2 mm sheet steel with "zinctec" finish. Type 1 2 3 31 32 4 5 51 6 Cat. No. 951057 951058 951068 951069 951070 951059 951060 951061 951062 Weight 0.056 0.087 0.133 0.160 0.195 0.163 0.314 0.301 0.524 Type 7 71 8 9 91 10 11 12 Cat. No. 951063 951071 951064 951065 951066 951067 951064 951065 Weight 0.764 1.177 0.830 1.373 2.073 2.332 0.830 1.373 Earth continuity plates Internal continuity plates manufactured from 1.2 mm brass. May be used for bonding cable glands in any of the four enclosure faces. Type 1 2 3 31 32 4 5 51 6 Cat. No. 951099 951100 951101 951102 951103 951104 951105 951106 951107 Weight 0.071 0.104 0.151 0.192 0.221 0.230 0.450 0.389 0.645 Type 7 71 8 9 91 10 11 12 Cat. No. 951108 951109 951110 951111 951112 951113 951110 951111 Weight 0.904 1.351 1.144 1.776 2.494 2.611 1.144 1.776 3 mm single brass earth plates Manufactured from 3 mm brass for fitting along sides of enclosure. Type (long side) 4 5 6 7 8/11 9/12 10 51 71 (4 off per box) 91 (4 off per box) Cat. No. 306713 306978 306711 307222 307224 306708 306708 307226 307228 307230 Weight 0.096 0.244 0.285 0.422 0.411 0.717 0.717 0.155 0.316 0.533 Type (short side) 4 5 6 7 8/11 9/12 10 51 71 91 Cat. No. 306714 306979 306712 307223 307225 306710 306709 307227 307229 307231 Weight 0.067 0.076 0.110 0.100 0.330 0.328 0.624 0.102 0.099 0.325 Earth bar Type (Horiz. bar) Cat. No. No. of Poles 4 6 6 8 8 8 8 12 12 12 8 12 12 x 2 mm zinc plated steel bar complete with cable clamps having locking tongue which locates in the bar. Bars are secured to base of enclosure either directly to the brass inserts or pillars fitted to brass inserts. 4 5 51 6 7 71 8 9 91 10 11 12 951120 951121 951122 951123 951124 951125 951126 951127 951128 951127 951126 951127 Stand off pilars Plated mild steel, supplied in packs of 2. Not suitable for enclosure sizes 1, 2, 3, 31 or 32. Type HR 15 HR 30 Cat. No. 389610 389630 Earth pillar kit Brass nickeld plated earthing kits comprising of 1 earth bar and 2 pillars. Provide additional earthing facilities within enclosure. Suitable for enclosure sizes 1, 2, 31 + 32 only. Type Cat. No. 157010 Earth studs Mounting feet Supplied in sets of 4. Complete with fixing screws. 56 Height 15 mm 30 mm Type M6 Brass M6 Stainless steel M10 Brass M10 Stainless steel Cat. No. 950270 950524 950271 950087 Type MF5 MF6 Cat. No. Size 951090 Small size 1, 2, 3, 31, 32 951091 Large, all other sizes 18.6 19.9 87.9 85.9 Weight grams grams grams grams (Vert. bar) Cat. No. 951116 951116 951117 951117 951117 951117 951118 951118 951118 951119 951118 951118 No. of Poles 2 2 4 4 4 4 6 6 6 8 6 6 Terminal selection guide Glanding Area´s with 3mm brass plates or earth continuity plates fitted The tables shown under each enclosure type are given as a guide only, allowances have been made for the fitting of one end section and two end brackets on each rail. The number of terminals must be reduced if partitions or extra end sections are requiered. Clearance between banks and between terminal bank and enclosure wall has been based on following table, if clearance larger than those described are required number of terminals must be reduced. The number of terminals per enclosure can be increased to maximum by countersunk drilling of the assembly rail and the use of countersunk fixing screws. Terminals may then be fitted over screw head after assembly rail is fitted in the enclosure. Clearance Dimension Table Conductor Size mm2 2.5 4 6 10 16 25 35 Dim 'A' mm 20 25 30 40 50 60 75 Dim 'B' mm 40 50 60 80 100 120 150 3 mm plates Enclosure Type 1 2 3 31 32 4 5 51 6 7 71 8 9 91 10 11 12 continuity plates Side A+B Side C+D 85 x 45 178 x 50 212 x 53 310 x 53 206 x 80 237 x 52* 206 x 80 352 x 80 260 x 80* 352 x 80 206 x 80 352 x 80 60 x 45 60 x 50 82 x 48 82 x 48 170 x 75 82 x 47 170 x 75 172 x 75 170 x 75 327 x 75 170 x 75 172 x 75 Side A+B 43 x 26 73 x 26 123 x 22 154 x 24 83 x 27* 83 x 46 177 x 51 111 x 54 211 x 53 311 x 53 237 x 52* 206 x 80 351 x 81 259 x 80 351 x 80 206 x 80 351 x 81 Side C+D 26 x 26 26 x 26 26 x 22 26 x 24 26 x 27 55 x 46 55 x 51 81 x 54 81 x 53 81 x 53 81 x 52 171 x 80 171 x 81 168 x 80 326 x 80 171 x 80 171 x 81 * Two area´s each side A + B The number of terminals which can be fitted to a certified enclosure is limited by the certification criterion, for assistance call the "Weidmüller" representative. 57 Terminal Content Guide depending on the cable size and permitted current In this area you can add as many terminals as physically possible KE 1 / POK 1 KE 2 / POK 2 Conductor Size (mm2) Conductor Size (mm2) 1,5 2,5 4 6 KE 4 / POK 4 10 16 1,5 C u r r e n t 8 28 10 14 12 21 (A) 14 12 C u r r e n t 16 5 (A) 8 30 10 14 2,5 12 22 14 13 16 9 4 Conductor Size (mm2) 6 10 16 1,5 37 19 6 44 C u r r e n t 10 21 (A) 10 2,5 12 32 14 19 16 14 19 4 1,5 8 48 10 23 2,5 C u r r e n t 12 35 14 21 16 15 (A) 19 4 6 16 61 20 22 1,5 8 51 10 25 2,5 4 6 10 40 16 16 17 (A) 19 C u r r e n t 24 16 (A) 25 34 28 24 64 16 22 13 28 12 KE 8 / POK 8 Conductor Size (mm2) 10 27 12 41 C u r r e n t 14 25 16 18 (A) 25 47 28 36 19 16 70 23 22 37 1,5 8 73 10 35 69 23 22 25 45 36 50 17 55 12 KE 9 / POK 9 2,5 4 6 Conductor Size (mm2) 10 12 54 C u r r e n t 14 32 16 23 (A) 25 58 28 46 19 16 92 31 22 48 1,5 8 79 10 38 2,5 4 6 10 12 58 C u r r e n t 14 35 16 25 (A) 25 95 28 82 19 22 16 100 33 60 45 37 45 49 45 53 50 18 50 23 50 25 55 12 55 16 55 18 KE 91 / POK 91 KE 10 / POK 10 Conductor Size (mm2) 1,5 8 81 10 39 2,5 4 6 Conductor Size (mm2) 10 16 1,5 8 90 10 46 2,5 4/6 6 10 12 60 12 70 C u r r e n t 14 36 42 16 26 C u r r e n t 14 16 31 (A) 25 142 (A) 40 82 28 130 45 63 19 22 102 34 61 19 22 25 120 40 123 45 54 63 50 50 26 68 33 55 18 70 25 Different types of terminals can be used together by utilising the tabular values proportionally: Example (KE7/POK7) Conductor Size (mm2) Current (Amps) 1.5 10 2.5 16 58 19 Conductor Size (mm2) 10 6 14 19 56 26 4 22 28 8 10 2,5 14 23 6 55 12 25 4 8 37 30 2,5 1,5 16 12 25 1,5 16 8 C u r r e n t 20 KE 7 / POK 7 10 10 Conductor Size (mm2) Conductor Size (mm2) 10 16 KE 6 / POK 6 KE 51 / POK 51 Conductor Size (mm2) 10 55 22 KE 5 / POK 5 6 Number 16 (of 27) 6 (of 18) Load ≤ 100 = 59.30 = 33.30 92.60 % % % %