Preview only show first 10 pages with watermark. For full document please download

Key Notes: Seismic Notes - Peck Ormsby Construction

   EMBED


Share

Transcript

R O F I C I E N P T 3 2 5 4 7 6 8 9 peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com R J H H 6 G RTU-1 F.9 6 ISSUED FOR CONSTRUCTION 4 ISSUE / REVISIONS: 3 DATE RTU-3 7 2 DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID 2 7 7 (ON ROOF) 4 2 2 4 (SEE KITCHEN SHEETS M400 - M404) 4 4 4 SEAL: 02.07.2014 F RTU-2 4 D.9 RTU-4 3 7 2 E 1 4 4 4 4 7 7 4 6 4 2 R PROJECT NAME & ADDRESS 2 D C B 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH 5 6 B A 1 2 3 4 5 7 6 1 M100 FLOOR PLAN KEY NOTES: 8 9 SEISMIC NOTES: PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: 1/4" = 1'-0" 1 THERMOSTATS SHALL BE LOCATED IN OFFICE WITH LOCK OUT SCREEN. LABEL THERMOSTAT WITH CORRESPONDING RTU TAG. WIRE TO REMOTE SENSORS. 2 UNDERCUT DOOR 3/4" 3 BY-PASS SA DUCT. BALANCE BY-PASS CFM PER RTU SCHEDULE. HVAC DUCTS ARE EXEMPT BECAUSE THEY HAVE A CROSS-SECTIONAL AREA OF LESS THAN 6 SQ. FT. UNLESS OTHERWISE OVERRULED BY LOCAL SEISMIC REQUIREMENTS. 4 FLY FAN MOUNTED ABOVE DOOR ON EXTERIOR WALL. CONTROLLED BY DOOR SWITCH. MARS AIR DOOR STD 36-1. ROOFTOP UNITS SHALL HAVE VIBRATION ISOLATION SUPPORTS AND USE FLEXIBLE DUCT/PIPING CONNECTIONS. SEE DETAIL AND SPECIFICATIONS ON SHEET M301. 5 ELECTRIC WALL HEATER. 175 CFM, 1,000 W, INTEGRAL T'STAT TO MAINTAIN 45 F (ADJ.), SEE ELECTRICAL DRAWING FOR POWER, BASIS OF DESIGN: MARKEL (APPROVED EQUIVALENTS MAY BE ACCEPTED) 6 DIFFUSER TO BE MINIMUM 11'-0" ABOVE FINISHED FLOOR. 7 INSULATED DOUBLE WALL SPIRAL PIPE HVAC SYSTEM SHALL BE INSTALLED IN STRICT ACCORDANCE WITH ASCE 7-05 CHAPTER 13 AND ALL LOCAL SEISMIC REQUIREMENTS. HVAC COMPONENTS ON THIS PROJECT SHALL BE ASSIGNED AN IMPORTANCE FACTOR (IP) OF 1.0. FLOOR PLAN PROJECT #: 14-820.00 M100 R O F I C I E N P T peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com R ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID DIFFUSER, GRILLE, AND REGISTER SCHEDULE FACE SIZE (IN) INLET SIZE (IN) NOISE CRITERIA @ MAX CFM MODEL QUANTITY EC0606 EGGCRATE GRILL 6x6 6x6 25 TITUS 50F 3 RC2424 EGGCRATE GRILL 24x24 24x24 25 TITUS 50F 2 SC0804 DOUBLE DEFLECTION REGISTER 10x6 8x4 25 TITUS 300FS 5 SCL06 LOUVERED FACE SUPPLY 24x24 25 TITUS TMS 3 SCL08 LOUVERED FACE SUPPLY 24x24 25 TITUS TMS 3 SCL10 LOUVERED FACE SUPPLY 24x24 25 TITUS TMS 4 SS1206 DOUBLE DEFLECTION SUPPLY 14x8 25 TITUS 300FS 16 12x6 SEAL: 02.07.2014 PROJECT NAME & ADDRESS R DESCRIPTION 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH CALLOUT PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: SCHEDULES PROJECT #: 14-820.00 M200 R NO SCALE NO SCALE REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL CEILING MOUNTED EQUIPMENT. ROOF EXHAUST FANS SHALL BE CENTRIFUGAL DIRECT DRIVE TYPE. THE FAN WHEEL SHALL BE CENTRIFUGAL BACKWARD INCLINED, CONSTRUCTED OF ALUMINUM AND SHALL INCLUDE A WHEEL CONE CAREFULLY MATCHED TO THE INLET CONE FOR PRECISE RUNNING TOLERANCES. WHEELS SHALL BE STATICALLY AND DYNAMICALLY BALANCED. THE FAN HOUSING AND SHROUD SHALL BE CONSTRUCTED OF HEAVY GAUGE ALUMINUM AND SHALL INCLUDE A WHEEL CONE CAREFULLY MATCHED TO THE INLET CONE FOR PRECISE RUNNING TOLERANCES. WHEELS SHALL BE STATICALLY AND DYNAMICALLY BALANCED. PORTIONS OF DUCTWORK OR PIPING VISIBLE THROUGH GRILLES AND REGISTERS IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. PAINT BLACK BEHIND ALL GRILLES. ALL FIRE SEPARATIONS MUST BE PROTECTED WHEN APPLICABLE. TEST AND BALANCE: COORDINATE ROOF OPENING SIZE WITH ARCHITECT & STRUCTURAL ROUTE POWER CONN. INSIDE CURB BACKDRAFT DAMPER THE CONTRACTOR SHALL RETAIN THE SERVICES OF AN INDEPENDENT TEST AND BALANCE AGENCY THAT IS INDEPENDENT OF ANY CONTRACTOR, SUB-CONTRACTOR, OR MANUFACTURER TO PERFORM THE TESTING AND BALANCING AND PREPARE REPORTS TO THE GENERAL CONTRACTOR. THE INDEPENDENT TEST AND BALANCE AGENCY SHALL BE A CERTIFIED MEMBER OF THE ASSOCIATED AIR BALANCE COUNCIL OR THE NATIONAL ENVIRONMENTAL BALANCING BUREAU. TEST AND BALANCE SHALL ALSO PROVIDE QUOTE TO PERFORM BALANCING FOR COMFORT SIX MONTHS AFTER THE SPACE IS OCCUPIED. SEE CONNECTION OPTIONS BELOW DUCTWORK SEE FLOOR PLANS. CL DUCTWORK AND ACCESSORIES: INDUSTRY STANDARDS: COMPLY WITH SMACNA (SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION) HVAC DUCT CONSTRUCTION STANDARDS, RECOMMENDATIONS FOR FABRICATION, GAUGES, CONSTRUCTION AND DETAILS, AND INSTALLATION PROCEDURES, EXCEPT AS OTHERWISE INDICATED. COMPLY WITH ASHRAE (AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR CONDITIONING ENGINEERS) FUNDAMENTALS HANDBOOK RECOMMENDATIONS, EXCEPT AS OTHERWISE INDICATED. CONDENSATE TRAP (DRAW THROUGH UNIT) DUCTWORK METAL AND GAUGES: EXCEPT AS OTHERWISE INDICATED, FABRICATE DUCTWORK FROM GALVANIZED SHEET STEEL COMPLYING WITH ASTM A527, LOCKFORMING QUALITY, WITH ASTM A525 G90 ZINC COATING, MILL PHOSPHATIZED. GAUGES TO COMPLY WITH SMACNA STANDARDS. NO SCALE DUCT SEALANT: NON-HARDENING, NON-MIGRATING MASTIC OR LIQUID ELASTIC SEALANT (TYPE APPLICABLE FOR THE FABRICATION/INSTALLATION DETAIL) AS COMPOUNDED AND RECOMMENDED BY THE MANUFACTURER SPECIFICALLY FOR SEALING JOINTS AND SEAMS IN DUCTWORK. DUCTWORK SUPPORT MATERIALS: EXCEPT AS OTHERWISE INDICATED, PROVIDE UPPER ATTACHMENT, HANGERS OF GALVANIZED STEEL STRAPS, OR STEEL RODS AND LOWER ATTACHMENT FOR SUPPORT OF DUCTWORK. HANGING/SUPPORT SYSTEMS SHALL BE IN ACCORDANCE WITH SMACNA REQUIREMENTS. CLEANOUT CAP, CLOSED DURING UNIT OPERATION TANSITION DUCT TO FULL SIZE OF ROOFTOP OPENING. EXPOSED DUCTWORK SHALL BE INSULATED DOUBLE WALL SPIRAL PIPE UNLESS OTHERWISE NOTED OR SUBSTITUTION APPROVED BY OWNER. PIPE FULL SIZE AIR UNIT DRAIN CONNECTION, MINIMUM SEE FLOOR PLANS FOR SIZES AIR UNIT CASING OPEN END PIPE (EXTERIOR) CAPPED (INTERIOR) INSTALL CARBON STEEL OF MINIMUM 16 GAUGE OR STAINLESS STEEL MINIMUM 18 GAGE IN STRICT ACCORDANCE WITH NFPA-96. THE ENTIRE DUCT SYSTEM, FROM HOOD OUTLETS TO FAN INLET, SHALL BE WRAPPED WITH ASTM-814 CERTIFIED DUCT WRAP FOR ZERO CLEARANCE TO COMBUSTIBLES. FOLLOW DUCT WRAP MANUFACTURERS INSTRUCTIONS FOR INSTALLATION AND THROUGH WALL PENETRATIONS. DUCT INSULATION: FLOW X3 MINIMUM MINIMUM MINIMUM MINIMUM X2 X1 =1" PLUS MAXIMUM NEGATIVE STATIC PRESSURE X2 =HALF OF X1 X3 = NOTES 1. LOCATE TRAPS SO AS TO BE ACCESSIBLE FOR CLEANING. EXTEND FULL SIZE OF ROOFTOP RA OPENING AND PROVIDE DUCT CONNECTION PER FLOOR PLANS DIFFUSER TAKE-OFF DETAIL EXTEND DUCTS FULL SIZE ROOFTOP OPENING AND PROVIDE DUCT CONNECTION PER FLOOR PLANS REFER TO FLOOR PLANS TO DETERMINE WHICH CONNECTION SHALL BE INSTALLED. 2. COORDINATE EXACT LOCATION OF ROOF OPENING WITH ARCHITECT AND STRUCTURAL. 3. WHERE SUPPLY AIR BY-PASS IS SCHEDULED, PROVIDE BY-PASS IN ROOF CURB WITH MANUAL VOLUME DAMPER ACCESSIBLE FROM ROOF. SUPPLY AIR DUCT INSULATION SUPPLY AND RETURN AIR DUCT INSULATION IN UNCONDITIONED SPACES SUPPLY AND RETURN AIR DUCT INSULATION OUTSIDE THE BUILDING INSULATION BETWEEN DUCTS AND THE BUILDING EXTERIOR WHEN DUCTS ARE PART OF A BUILDING ASSEMBLY ROOF EXHAUST FANS SHALL BE UPBLAST CENTRIFUGAL BELT DRIVEN TYPE. THE FAN WHEEL SHALL BE CENTRIFUGAL BACKWARD INCLINED, CONSTRUCTED OF ALUMINUM AND SHALL INCLUDE A WHEEL CONE CAREFULLY MATCHED TO THE INLET CONE FOR PRECISE RUNNING TOLERANCES. WHEELS SHALL BE STATICALLY AND DYNAMICALLY BALANCED. THE FAN HOUSING SHALL BE CONSTRUCTED OF HEAVY GAUGE ALUMINUM WITH A RIGID INTERNAL SUPPORT STRUCTURE. WINDBANDS SHALL HAVE A ROLLED BEAD FOR ADDED STRENGTH AND SHALL BE JOINED TO CURBCAPS WITH A LEAKPROOF, CONTINUOUSLY WELDED SEAM. MOTORS SHALL BE HEAVY DUTY BALL BEARING TYPE, CAREFULLY MATCHED TO THE FAN LOAD, AND FURNISHED AT THE SPECIFIED VOLTAGE, PHASE AND ENCLOSURE. MOTORS AND DRIVES SHALL BE MOUNTED ON VIBRATION ISOLATORS, OUT OF THE AIRSTREAM. FRESH AIR FOR MOTOR COOLING SHALL BE DRAWN INTO THE MOTOR COMPARTMENT FROM AN AREA FREE OF DISCHARGE CONTAMINANTS. MOTORS SHALL BE READILY ACCESSIBLE FOR MAINTENANCE. DRIVE FRAME ASSEMBLIES SHALL BE CONSTRUCTED OF HEAVY GAUGE STEEL AND MOUNTED ON VIBRATION ISOLATORS. PRECISION GROUND AND POLISHED FAN SHAFTS SHALL BE MOUNTED IN PERMANENTLY SEALED, LUBRICATED PILLOW BLOCK BALL BEARINGS. BEARINGS SHALL BE SELECTED FOR A MINIMUM (L10) LIFE IN EXCESS OF 100,000 HOURS AT MAXIMUM CATALOGED OPERATING SPEED. DRIVES SHALL BE SIZED FOR A MINIMUM OF 150%%% OF DRIVEN HORSEPOWER. PULLEYS SHALL BE OF THE FULLY MACHINED CAST IRON TYPE, KEYED AND SECURELY ATTACHED TO THE WHEEL AND MOTOR SHAFTS. NO SCALE 1. R-5 R-5 R-8 R-8 KITCHEN EXHAUST FAN WHERE: NOTES: GREASE EXHAUST DUCTWORK SHALL BE FACTORY FABRICATED EQUAL TO SELKIRK METALBESTOS ZEROCLEAR MODEL IPS-Z3. INSTALL DUCTWORK IN ACCORDANCE WITH UL 1978 AND UL 2221 INSTALLATION INSTRUCTIONS. COMPLETE SYSTEM, FROM HOOD OUTLETS TO FAN INLET SHALL, INCLUDE TRANSITIONS TO HOOD OUTLETS, ADJUSTABLE PIPE LENGTHS, SUPPORT PLATES, GUIDE RINGS, ACCESS DOORS, AND THRU WALL FIRE STOP PENETRATIONS. MODEL IPS-C1 OR MODEL G MAY BE USED WHERE CLEARANCES PERMIT. VOLUNTARY ALTERNATE GREASE DUCT AND WRAP SYSTEM: X1 EXTEND FULL SIZE OF SA OPENING AND PROVIDE DUCT CONNECTION PER FLOOR PLANS GREASE DUCT SYSTEM: NYLON TIE ON EXTERIOR INSULATION NYLON TIE ON INTERNAL LINER INTERIOR LINER MOTOR PULLEYS SHALL BE ADJUSTABLE FOR FINAL SYSTEM BALANCING. A DISCONNECT SWITCH SHALL BE FACTORY INSTALLED AND WIRED FROM THE FAN MOTOR TO A JUNCTION BOX INSTALLED WITHIN THE MOTOR COMPARTMENT. A CONDUIT CHASE SHALL BE PROVIDED THROUGH THE CURB CAP TO THE MOTOR COMPARTMENT FOR EASE OF ELECTRICAL WIRING. FANS SHALL BE MANUFACTURED BY CAPTIVEAIR OR APPROVED EQUIVALENT. PREINSULATED FLEXIBLE DUCTWORK. SEE SPECIFICATIONS. LENGTH SHALL NOT EXCEED 8'-0". PROVIDE SUPPORT PER SMACNA STANDARDS. INSTALL FREE OF KINKS & SAGS. ROUND SHEET METAL DUCT DIAMETER AS INDICATED ON PLANS. DAMPER HERE FOR INACCESSIBLE CEILINGS (I.E. HARD CEILINGS) BRANCH DUCT SPIN-IN FITTING WITH SCOOP DAMPER HERE FOR ACCESSIBLE CEILINGS NOTE: CONNECT FLEX DUCT ENDS TO SHEET METAL DUCT AND DIFFUSER NECK WITH NYLON TIES. INTERIOR LINER AND EXTERIOR INSULATION OF FLEX DUCT TO BE TIED INDIVIDUALLY. INSTALL USING TENSIONING TOOL AS PER MANUFACTURER'S RECOMMENDATIONS. CEILING SEE ARCH. ROOF MAKE-UP AIR FAN ROOF MOUNTED, FILTERED, MAKE-UP AIR UNITS SHALL BE OF THE BELT-DRIVEN, DOUBLE WIDTH/DOUBLE INLET, FORWARD CURVED, CENTRIFUGAL BLOWER TYPE. THE HOOD SHALL BE CONSTRUCTED OF HEAVY GAUGE GALVANIZED STEEL AND ADEQUATELY SIZED TO PREVENT RAIN AND SNOW FROM ENTERING THE BUILDING. THE COVER SHALL BE CONSTRUCTED OF HEAVY GAUGE GALVANIZED STEEL, REMOVABLE FOR SERVICE. HOOD BASES SHALL HAVE PREPUNCHED MOUNTING HOLES. PERMANENT WASHABLE 1 IN ALUMINUM FILTERS SHALL BE PROVIDED. FAN WHEELS SHALL BE OF THE FORWARD CURVED TYPE, CONSTRUCTED OF HEAVY GAUGE STEEL, AND STATICALLY AND DYNAMICALLY BALANCED TO ENSURE SMOOTH, VIBRATION FREE OPERATION. MOTORS SHALL BE PERMANENTLY LUBRICATED, HEAVY DUTY, BALL BEARING TYPE CAREFULLY MATCHED TO THE FAN LOAD AND FURNISHED AT THE SPECIFIED VOLTAGE, PHASE AND ENCLOSURE. SUPPLY DIFFUSER THE FAN SHAFT SHALL BE GROUND AND POLISHED STEEL MOUNTED IN HEAVY DUTY, SEALED BALL BEARINGS. BEARINGS SHALL BE SELECTED FOR A MINIMUM (L50) LIFE IN EXCESS OF 200,000 HOURS AT MAXIMUM CATALOGED OPERATING SPEEDS. PULLEYS SHALL BE OF THE FULLY MACHINED CAST IRON TYPE, KEYED AND SECURELY ATTACHED TO THE WHEEL AND MOTOR SHAFTS. MOTOR SHEAVES SHALL BE ADJUSTABLE FOR FINAL SYSTEM BALANCING. DRIVES SHALL BE SIZED FOR A MINIMUM OF 150%%% OF DRIVEN HORSEPOWER. THE ENTIRE FAN AND MOTOR ASSEMBLY SHALL BE MOUNTED ON VIBRATION ISOLATORS TO PREVENT NOISE TRANSMISSION. THE MAKE-UP AIR UNITS SHALL BEAR THE AMCA CERTIFIED RATINGS SEAL FOR AIR AND SOUND PERFORMANCE. FANS SHALL BE CAPTIVEAIRE OR APPROVED EQUIVALENT. G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 THE FAN HOUSING AND SHROUD SHALL BE CONSTRUCTED OF HEAVY GAUGE ALUMINUM WITH A RIGID INTERNAL SUPPORT STRUCTURE. THE FAN SHROUD SHALL HAVE A ROLLED BEAD FOR ADDED STRENGTH. MOTORS SHALL BE MOUNTED OUT OF THE AIRSTREAM ON VIBRATION ISOLATORS. FRESH AIR FOR MOTOR COOLING SHALL BE DRAWN INTO THE MOTOR COMPARTMENT FROM AN AREA FREE OF DISCHARGE CONTAMINANTS. MOTORS SHALL BE READILY ACCESSIBLE FOR MAINTENANCE. A DISCONNECT SWITCH SHALL BE FACTORY INSTALLED AND WIRED FROM THE MOTOR COMPARTMENT FOR EASE OF ELECTRICAL WIRING. p 404.330.9798 www.peiatl.com R ALL FANS SHALL BEAR THE AMCA CERTIFIED RATINGS SEAL FOR SOUND AND AIR PERFORMANCE. EACH FAN SHALL BEAR A PERMANENTLY AFFIXED MANUFACTURER'S NAMEPLATE CONTAINING THE MODEL NUMBER AND INDIVIDUAL SERIAL NUMBER FOR FUTURE IDENTIFICATION. ROOFTOP UNITS: GENERAL OUTDOOR, ROOFTOP MOUNTED, ELECTRICALLY CONTROLLED, HEATING AND COOLING UNIT UTILIZING A FULLY HERMETIC SCROLL COMPRESSOR(S) FOR COOLING DUTY AND GAS COMBUSTION FOR HEATING DUTY. FACTORY ASSEMBLED, SINGLE-PIECE HEATING AND COOLING ROOFTOP UNIT. CONTAINED WITHIN THE UNIT ENCLOSURE SHALL BE ALL FACTORY WIRING, PIPING, CONTROLS, AND SPECIAL FEATURES REQUIRED PRIOR TO FIELD START-UP. UNIT SHALL USE ENVIRONMENTALLY SOUND, PURON REFRIGERANT. UNIT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. UNIT MUST BE SELECTED AND INSTALLED IN COMPLIANCE WITH LOCAL, STATE, AND FEDERAL CODES. UNIT CABINET UNIT CABINET SHALL BE CONSTRUCTED OF GALVANIZED STEEL, AND SHALL BE BONDERIZED AND COATED WITH A PRE-PAINTED BAKED ENAMEL FINISH ON ALL EXTERNALLY EXPOSED SURFACES. ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: STANDARD HEAT EXCHANGER CONSTRUCTION HEAT EXCHANGER SHALL BE OF THE TUBULAR-SECTION TYPE CONSTRUCTED OF A MINIMUM OF 20-GAUGE STEEL COATED WITH A NOMINAL 1.2 MIL ALUMINUM-SILICONE ALLOY FOR CORROSION RESISTANCE. BURNERS SHALL BE OF THE IN-SHOT TYPE CONSTRUCTED OF ALUMINUM-COATED STEEL. BURNERS SHALL INCORPORATE ORIFICES FOR RATED HEAT OUTPUT UP TO 2000 FT (610M) ELEVATION. ADDITIONAL ACCESSORY KITS MAY BE REQUIRED FOR APPLICATIONS ABOVE 2000 FT (610M) ELEVATION, DEPENDING ON LOCAL GAS SUPPLY CONDITIONS. EACH HEAT EXCHANGER TUBE SHALL CONTAIN MULTIPLE DIMPLES FOR INCREASED HEATING EFFECTIVENESS. DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID STANDARD ALUMINUM/COPPER COILS: STANDARD EVAPORATOR AND CONDENSER COILS SHALL HAVE ALUMINUM LANCED PLATE FINS MECHANICALLY BONDED TO SEAMLESS INTERNALLY GROOVED COPPER TUBES WITH ALL JOINTS BRAZED. EVAPORATOR COILS SHALL BE LEAK TESTED TO 150 PSIG, PRESSURE TESTED TO 450 PSIG, AND QUALIFIED TO UL 1995 BURST TEST AT 1775 PSIG. CONDENSER COILS SHALL BE LEAK TESTED TO 150 PSIG, PRESSURE TESTED TO 650 PSIG, AND QUALIFIED TO UL 1995 BURST TEST AT 1980 PSIG. COMPRESSORS UNIT SHALL USE FULLY HERMETIC, SCROLL COMPRESSOR FOR EACH INDEPENDENT REFRIGERATION CIRCUIT. FILTER SECTION FILTERS ACCESS IS SPECIFIED IN THE UNIT CABINET SECTION OF THIS SPECIFICATION. FILTERS SHALL BE HELD IN PLACE BY A PIVOTING FILTER TRAY, FACILITATING EASY REMOVAL AND INSTALLATION. SHALL CONSIST OF FACTORY-INSTALLED, LOW VELOCITY, THROW-AWAY 2-IN. THICK FIBERGLASS FILTERS. FILTERS SHALL BE STANDARD, COMMERCIALLY AVAILABLE SIZES. EVAPORATOR FAN AND MOTOR EVAPORATOR FAN MOTOR: SHALL HAVE PERMANENTLY LUBRICATED BEARINGS. SHALL HAVE INHERENT AUTOMATIC-RESET THERMAL OVERLOAD PROTECTION OR CIRCUIT BREAKER. SHALL HAVE A MAXIMUM CONTINUOUS BHP RATING FOR CONTINUOUS DUTY OPERATION; NO SAFETY FACTORS ABOVE THAT RATING SHALL BE REQUIRED. BELT-DRIVEN EVAPORATOR FAN: BELT DRIVE SHALL INCLUDE AN ADJUSTABLE-PITCH MOTOR PULLEY. SHALL USE SEALED, PERMANENTLY LUBRICATED BALL-BEARING TYPE. BLOWER FAN SHALL BE DOUBLE-INLET TYPE WITH FORWARD-CURVED BLADES. SHALL BE CONSTRUCTED FROM STEEL WITH A CORROSION RESISTANT FINISH AND DYNAMICALLY BALANCED. CONDENSER FANS AND MOTORS CONDENSER FAN MOTORS: SHALL BE A TOTALLY ENCLOSED MOTOR. SHALL USE PERMANENTLY LUBRICATED BEARINGS. SHALL HAVE INHERENT THERMAL OVERLOAD PROTECTION WITH AN AUTOMATIC RESET FEATURE. SHALL USE A SHAFT-DOWN DESIGN ON 04 TO 12 MODELS AND SHAFT-UP ON 14 SIZE WITH RAIN SHIELD. CONDENSER FANS: SHALL BE A DIRECT-DRIVEN PROPELLER TYPE FAN. SHALL HAVE ALUMINUM BLADES RIVETED TO CORROSION-RESISTANT STEEL SPIDERS AND SHALL BE DYNAMICALLY BALANCED. ACCESSORIES MANUAL DAMPER MANUAL DAMPER PACKAGE SHALL CONSIST OF DAMPER, AIR INLET SCREEN, AND RAIN HOOD WHICH CAN BE PRESET TO ADMIT UP TO 25 OR 50% OUTDOOR AIR FOR YEAR ROUND VENTILATION. CONVENIENCE OUTLET: POWERED CONVENIENCE OUTLET. ROOF CURBS (VERTICAL): FULL PERIMETER ROOF CURB WITH EXHAUST CAPABILITY PROVIDING SEPARATE AIR STREAMS FOR ENERGY RECOVERY FROM THE EXHAUST AIR WITHOUT SUPPLY AIR CONTAMINATION. FORMED GALVANIZED STEEL WITH WOOD NAILER STRIP AND SHALL BE CAPABLE OF SUPPORTING ENTIRE UNIT WEIGHT. PERMITS INSTALLATION AND SECURING OF DUCTWORK TO CURB PRIOR TO MOUNTING UNIT ON THE CURB. SMOKE DETECTORS: SHALL BE A FOUR-WIRE CONTROLLER AND DETECTOR. SHALL BE ENVIRONMENTAL COMPENSATED WITH DIFFERENTIAL SENSING FOR RELIABLE, STABLE, AND DRIFT-FREE SENSITIVITY. SHALL USE MAGNET-ACTIVATED TEST/RESET SENSOR SWITCHES. SHALL HAVE TOOL-LESS CONNECTION TERMINAL ACCESS. SHALL HAVE A RECESSED MOMENTARY SWITCH FOR TESTING AND RESETTING THE DETECTOR. CONTROLLER SHALL INCLUDE: (1.) ONE SET OF NORMALLY OPEN ALARM INITIATION CONTACTS FOR CONNECTION TO AN INITIATING DEVICE CIRCUIT ON A FIRE ALARM CONTROL PANEL. (2.) TWO FORM-C AUXILIARY ALARM RELAYS FOR INTERFACE WITH ROOFTOP UNIT OR OTHER EQUIPMENT. (3.) ONE FORM-C SUPERVISION (TROUBLE) RELAY TO CONTROL THE OPERATION OF THE TROUBLE LED ON A REMOTE TEST/RESET STATION. (4.) CAPABLE OF DIRECT CONNECTION TO TWO INDIVIDUAL DETECTOR MODULES. (5.) CAN BE WIRED TO UP TO 14 OTHER DUCT SMOKE DETECTORS FOR MULTIPLE FAN SHUTDOWN APPLICATIONS THERMOSTATS: ELECTRIC, SOLID-STATE, MICROCOMPUTER-BASED THERMOSTAT WITH REMOTE ROOM SENSOR. AUTOMATIC SWITCHING FROM HEATING TO COOLING. PREFERENTIAL RATE CONTROL TO MINIMIZE OVERSHOOT AND DEVIATION FROM SET POINT. SET UP FOR FOUR SEPARATE TEMPERATURES PER DAY. INSTANT OVERRIDE OF SET POINT FOR CONTINUOUS OR TIMED PERIOD FROM 1 HOUR TO 31 DAYS. SHORT-CYCLE PROTECTION. PROGRAMMING BASED ON EVERY DAY OF WEEK. ON-AUTO. BATTERY REPLACEMENT WITHOUT PROGRAM LOSS. THERMOSTAT DISPLAY FEATURES INCLUDE THE FOLLOWING: TIME OF DAY. ACTUAL ROOM TEMPERATURE. PROGRAMMED TEMPERATURE. PROGRAMMED TIME. DURATION OF TIMED OVERRIDE. DAY OF WEEK. SYSTEM MODE INDICATIONS INCLUDE "HEATING," "OFF," "FAN AUTO," AND "FAN ON." SEAL: 02.07.2014 PROJECT NAME & ADDRESS R MOUNTING FRAME OF CEILING MOUNTED AIR DISTRIBUTION DEVICES SHALL BE COMPATIBLE WITH CEILING TYPE. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPE. ROOF FLASHING SOUND INSULATION (TYP.) N ALL WIRING IN THE CEILING PLENUM SHALL BE PLENUM RATED CABLE. FACTORY FABRICATED ROOF HOOD PER FAN MANUFACTURER ROOF & STRUCTURE BY OTHERS SUPPLY/RETURN DUCT CONNECTIONS FULL SIZE OF ROOFTOP UNIT OPENINGS peiatl.com G ROOF CENTRIFUGAL EXHAUST FAN: 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH 14" HIGH FACTORY CURB WITH FLASHING & COUNTER-FLASHING BIRDSCREEN GENERAL NOTES: E CONDENSATE DRAIN & TRAP. SPECIFICATIONS (CONTINUED) OUTSIDE AIR DAMPER WITH MANUAL VOLUME DAMPER (MOTOR OPERATED IF SCHEDULE) SET TO SCHEDULED OUTSIDE AIR ROOFTOP UNIT SPECIFICATIONS N P ROOF CENTRIFUGAL EXHAUST FAN DETAIL F I C I E T ROOFTOP UNIT DETAIL O PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: SPECIFICATIONS & DETAILS PROJECT #: 14-820.00 M300 R N P FLAT ROOF CURBS ROOF CURBS FOR FLAT ROOFS WITH STANDARD DUCT SUPPORT ARE SPECIFIED ON THE DRAWINGS. SEE ROOF CURB DETAIL FOR MORE INFORMATION. ALL OTHER CURB TYPES ARE NOT DESCRIBED IN THIS SECTION. A. CONSTRUCTION: a. peiatl.com N G E COMMON) b. DOWN-TURNED TOP FLANGE TO ACCEPT PT 1X4 NAILER, ROOFING AND FIELD SUPPLIED COUNTER FLASHING. c. CORNERS SHALL BE FULLY MITERED AND WELDED. d. ALL WELDS COATED WITH ZINC-RICH PRIMER: SSPC-PAINT 20 TYPE II. F I C I E T CURB SPECIFICATION O G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 B. MATERIALS: MINIMUM 18 GAUGE G90 GALVANIZED STEEL, WATERTIGHT GASKETS, AND FACTORY INSTALLED PT 1X4 WOOD NAILER, COMPLYING WITH NRCA STANDARDS. www.peiatl.com OPTIONAL INSULATION 1. CURB INSULATION AND ADHESIVE: COMPLY WITH NFPA 90A OR NFPA 90B. a. MATERIALS: ASTM C 1071, TYPE I OR II. b. THICKNESS: 1 INCH OR GREATER. 2. INSULATION APPLICATION: FACTORY APPLIED WITH ADHESIVE AND MECHANICAL FASTENERS TO THE INTERNAL SURFACE OF CURB. a. LINER ADHESIVE: COMPLY WITH ASTM C 916, TYPE I. b. MECHANICAL FASTENERS: GALVANIZED STEEL, SUITABLE FOR ADHESIVE ATTACHMENT, MECHANICAL ATTACHMENT, OR WELDING ATTACHMENT TO DUCT WITHOUT DAMAGING LINER WHEN APPLIED AS RECOMMENDED BY MANUFACTURER AND WITHOUT CAUSING LEAKAGE IN CABINET. c. LINER MATERIALS APPLIED IN THIS LOCATION SHALL HAVE AIR-STREAM SURFACE COATED WITH A TEMPERATURE-RESISTANT COATING OR FACED WITH A PLAIN OR COATED FIBROUS MAT OR FABRIC DEPENDING ON SURFACE AIR VELOCITY. R ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID SEAL: 02.07.2014 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH R PROJECT NAME & ADDRESS PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: SEISMIC DETAILS PROJECT #: 14-820.00 M301 R O F I C I E N P T peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com 495 BUCKHURST DR., KERNERSVILLE, NC, 27284 PHONE: (336) 996-8484 FAX: (336) 996-0418 EMAIL: [email protected] PIEDMONT AREA OFFICE R ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID SEAL: 02.07.2014 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH R PROJECT NAME & ADDRESS PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: KITCHEN HOOD DRAWING MASTER DRAWING PROJECT #: 14-820.00 M400 R O F I C I E N P T peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com 495 BUCKHURST DR., KERNERSVILLE, NC, 27284 PHONE: (336) 996-8484 FAX: (336) 996-0418 EMAIL: [email protected] PIEDMONT AREA OFFICE R ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID SEAL: 02.07.2014 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH R PROJECT NAME & ADDRESS PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: KITCHEN HOOD DRAWING MASTER DRAWING PROJECT #: 14-820.00 M401 R O F I C I E N P T peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com 495 BUCKHURST DR., KERNERSVILLE, NC, 27284 PHONE: (336) 996-8484 FAX: (336) 996-0418 EMAIL: [email protected] PIEDMONT AREA OFFICE R ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID SEAL: 02.07.2014 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH R PROJECT NAME & ADDRESS PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: KITCHEN HOOD DRAWING MASTER DRAWING PROJECT #: 14-820.00 M402 R O F I C I E N P T peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com 495 BUCKHURST DR., KERNERSVILLE, NC, 27284 PHONE: (336) 996-8484 FAX: (336) 996-0418 EMAIL: [email protected] PIEDMONT AREA OFFICE R ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID SEAL: 02.07.2014 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH R PROJECT NAME & ADDRESS PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: KITCHEN HOOD DRAWING MASTER DRAWING PROJECT #: 14-820.00 M403 R O F I C I E N P T peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com 495 BUCKHURST DR., KERNERSVILLE, NC, 27284 PHONE: (336) 996-8484 FAX: (336) 996-0418 EMAIL: [email protected] PIEDMONT AREA OFFICE R ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID SEAL: 02.07.2014 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH R PROJECT NAME & ADDRESS PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: KITCHEN HOOD DRAWING MASTER DRAWING PROJECT #: 14-820.00 M404 SPECIFICATIONS (CONTINUED) ELECTRICAL LEGEND SYMBOLS CONDUCTORS: GROUNDING AND BONDING CONTRACTOR SHALL REFER TO ALL RELATED DOCUMENTS, ARCHITECTURAL, STRUCTURAL, CIVIL AND MEP DRAWINGS, AND FULLY UNDERSTAND THE SCOPE OF WORK AND CONDITION OF CONSTRUCTION. COPPER CONDUCTORS #10 AND SMALLER: ALL GROUNDING AND BONDING SHALL CONFORM TO NEC ARTICLE 250. LABELED PER UL 83, TYPE THHN/THWN, SOLID COPPER 600 VOLT INSULATION, UNIFORM COLOR CODED JACKET WITH JACKET DATA. METAL CLAD (TYPE MC) CABLE WHERE INSTALLED IN ACCORDANCE WITH NEC ARTICLE 334. COPPER WIRE OR CABLE INSULATED FOR 600V UNLESS REQUIRED BY APPLICABLE CODE OR AUTHORITIES HAVING JURISDICTION. ALL WORK SHALL BE COMPLETED TO THE SATISFACTION OF THE OWNER. IF ANY PORTION OF THE WORK IS FOUND UNSATISFACTORY BY THE OWNER, IT SHALL BE REMOVED AND REINSTALLED WITHOUT DELAY AT NO COST TO THE OWNER. COPPER CONDUCTORS #8 OR LARGER: LABELED PER UL 83, TYPE THHN/THWN, STRANDED COPPER, 600VOLT INSULATION, UNIFORM COLOR CODED JACKET WITH JACKET DATA. THE WORK INCLUDES, BUT NOT LIMITED TO: THE COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. ROUGH-IN AND FINAL CONNECTIONS TO ALL DEVICES REQUIRING ELECTRICAL POWER, INCLUDING OWNER PROVIDED EQUIPMENT. LIGHTING CONROL LIGHTING FIXTURES EACH CONTRACTOR SHALL OBTAIN ALL PERMITS AND INSPECTIONS REQUIRED BY THE REGULATORY AUTHORITIES. ALL FEES RELATED TO OBTAINING PERMITS AND INSPECTION SHALL BE PAID FOR BY EACH CONTRACTOR IN HIS TRADE. CONTRACTOR MAY USE ALUMINUM CONDUCTORS FOR #4 AWG OR LARGER IN THE PLACE OF COPPER CONDUCTORS. CONTRACTOR SHALL REFER TO NEC TABLE 310-16 FOR EQUIVALENT AMPACITY AND SHALL COMPENSATE FOR VOLTAGE DROP. ANY DIFFERENCES IN ABOVE MENTIONED REQUIREMENTS, THE MOST STERN SHALL OVERRULE ALL OTHERS. IN ADDITION TO ABOVE MENTIONED CODES AND SPECIFICATIONS, THE FOLLOWING INDUSTRY STANDARDS SHALL BE COMPLIED IF THEY ARE MORE STRINGENT. IEEE IES IECC 2009 ASHRAE 90.1 NFPA NEMA UL ADA THE MANUFACTURER'S PUBLISHED DIRECTIONS SHALL BE FOLLOWED IN THE DELIVERY, STORAGE, PROTECTION, INSTALLATION AND WIRING OF ALL EQUIPMENT AND MATERIAL. THE DRAWINGS SHOW DIAGRAMMATICALLY THE LOCATIONS OF THE VARIOUS LINES, CONDUITS, FIXTURES, AND EQUIPMENT AND THE METHOD OF CONNECTING AND CONTROLLING THEM. IT IS NOT INTENDED TO SHOW EVERY CONNECTION IN DETAIL AND ALL FITTINGS REQUIRED FOR A COMPLETE SYSTEM. THE SYSTEMS SHALL INCLUDE BUT ARE NOT LIMITED TO THE ITEMS SHOWN ON THE DRAWINGS. EXACT LOCATIONS OF THESE ITEMS SHALL BE DETERMINED BY REFERENCE TO THE GENERAL PLANS AND MEASUREMENTS AT THE BUILDING AND IN COOPERATION WITH THE OTHER SUBCONTRACTORS, AND IN ALL CASES, SHALL BE SUBJECT TO THE APPROVAL OF THE OWNER. THE OWNER RESERVES THE RIGHT TO MAKE ANY REASONABLE CHANGE IN THE LOCATION OF ANY PART OF THIS WORK WITHOUT ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL SEEK APPROVAL FROM THE OWNER FOR ANY CHANGES TO THE SPECIFICATIONS OR CONTRACT DOCUMENTS. INSTALL SOLID CONDUCTOR FOR #8 AWG AND SMALLER AND STRANDED CONDUCTORS FOR #6 OR LARGER. SUBMITTALS: PROVIDE PRODUCT DATA FOR EACH TRANSFORMER. INDICATE DIMENSIONS AND WEIGHTS. Atlanta, Georgia 30340 DUPLEX RECEPTACLE, 120V, 20A, NEMA 5-20R FLUSH WITH FINISHED FLOOR www.peiatl.com DUPLEX RECEPTACLE, 120V, 20A, NEMA 5-20R IN CEILING N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 p 404.330.9798 R SPECIAL RECEPTACLE, CONFIGURATION AND ELECTRICAL CHARACTERISTIC AS NOTED ON DWG 18" AFF INSULATION CLASS: 220 DEG C, UL COMPONENT RECOGNIZED INSULATION SYSTEM WITH MAXIMUM OF 150 DEG C RISE ABOVE 40 DEG C AMBIENT TEMPERATURE. J JUNCTION BOX FLUSH IN FINSHED FLOOR WITH COVER. SIZE PER NEC. FLUSH WITH FINISHED FLOOR COMPLY WITH NEMA TP1, CLASS 1 EFFICIENCY LEVELS AND TESTED ACCORDING TO NEMA TP2. S SWITCH 48" AFF TESTING AND INSPECTION: PERFORM VISUAL AND MECHANICAL INSPECTION AND ELECTRICAL TEST STATED IN NETA ACCEPTANCE TESTING SPECIFICATION. CERTIFY COMPLIANCE WITH TEST PARAMETERS. S3 SWITCH - 3 WAY 48" AFF S OS SWITCH - WALL MTD, INTEGRAL OCCUPANCY SENSOR 48" AFF S LV SWITCH - WALL MTD, LOW VOLTAGE, PILOT LIGHT 48" AFF SWITCH - CEILING MOUNTED OCCUPANCY SENSOR IN CEILING TV OUTLET 18" AFF MOLDED CASE CIRCUIT BREAKER: INCLUDE SCHEDULE OF ALL FUSES, RATINGS, TIME COORDINATION DATA, MANUFACTURER'S STANDARD DATA AND TIME-CURRENT CURVES. ALL DATA SHALL BE BASED ON TEST OF STANDARD PRODUCTS. APPROVED MANUFACTURERS: GENERAL ELECTRIC CUTLER HAMMER SQUARE D SIEMENS THERMAL-MAGNETIC BOLT-IN TYPE CIRCUIT BREAKERS WITH QUICK-MAKE, QUICK-BREAK CONTACTS; TRIP-FREE OPERATION WITH OVER-THE-CENTER TOGGLE HANDLE OR NON-REMOVABLE MONOLITHIC TIE-HANDLE. PERFORM AN INFRARED SCAN OF TRANSFORMER CONNECTIONS TWO MONTHS AFTER SUBSTANTIAL COMPLETION, PLUS 2 FOLLOW UP SCANS. ONE AT 4 MONTHS AND THE OTHER AT 11 MONTHS. PROVIDE CERTIFIED REPORT. ELECTRICAL GENERAL NOTES MULTI-POLE BREAKERS SHALL HAVE INTERNAL COMMON TRIP AND COMMON RESET WITH A SINGLE TOGGLE HANDLE OR NON-REMOVABLE MONOLITHIC TIE-HANDLE. 18" AFF TELEPHONE OUTLET. SUBSCRIPT: F - FIREMAN'S PHONE, H - HOUSE PHONE, P - PAY PHONE 48" AFF OR 6" ABOVE COUNTER TOP TELEPHONE / DATA COMBINATION OUTLET 18" AFF TELEPHONE / DATA COMBINATION OUTLET 48" AFF OR 6" ABOVE COUNTER TOP DATA OUTLET 18" AFF TRIP RATINGS SHALL BE MOLDED ON THE HANDLE OR FACE OF BREAKER. BREAKER TERMINALS SHALL BE RATED TO ACCOMMODATE A MINIMUM OF 75 DEGREE C. CONDUCTORS. 2. FIXTURE TYPE INDICATED BY UPPER CASE CHARACTERS, SWITCHING AND GROUPING DESIGNATED BY LOWER CASE LETTER AND CIRCUIT BY NUMBER (WHERE APPLICABLE). BREAKER SHALL BE RATED FOR MOUNTING AND OPERATION IN ANY POSITION; SHALL ACCOMMODATE AND MATCH THE TYPE OF TERMINATIONS REQUIRED. 3. WHEN CONDUCTOR OR CONDUIT SIZE IS INDICATED FOR BRANCH CIRCUIT HOME RUN, THE CONDUCTOR AND CONDUIT SIZE INDICATED SHALL BE USED FOR THE COMPLETE CIRCUIT. DATA OUTLET 48" AFF OR 6" ABOVE COUNTER TOP DISCONNECT SWITCH. SUBSCRIPT: AMP / # OF POLES / ENCLOSURE AS INDICATED ON DWG 4. REFER TO THE ARCHITECTURAL/INTERIORS DOCUMENTS FOR ACTUAL DEVICE LOCATIONS AND DIMENSIONS. FUSED DISCONNECT SWITCH. SUBSCRIPT: AMP / # OF POLES / ENCLOSURE / FUSE AS INDICATED ON DWG 5. REFER TO THE APPROPRIATE DRAWINGS FOR THE EXACT LOCATION OF EQUIPMENT INSTALLED UNDER OTHER DIVISIONS OF THE DOCUMENTS, WHICH REQUIRE ELECTRICAL SERVICE. ELECTRICAL PANELBOARD. REFER TO PANELBOARD SCHEDULE. SURFACE MOUNTED ON WALL EQUIPMENT AS NOTED ON DRAWING. SURFACE MOUNTED ON WALL SINGLE POLE BREAKERS RATED 15 AND 20 AMPERES SHALL BE UL LABELED AS "SWITCHING BREAKERS" AT THE APPLIED CIRCUIT VOLTAGE. MULTI-POLE BREAKERS RATED 100 AMPERES AND LARGER SHALL BE MOLDED CASE THERMAL-MAGNETIC BOLT-IN TYPE BREAKER WITH ADJUSTABLE INSTANTANEOUS TRIP. SUBMITTAL: ALL EXIT SIGNS, NIGHT LIGHTS AND EMERGENCY BALLAST CHARGING CIRCUITS SHALL BE CONNECTED TO UNSWITCHED PORTION OF LIGHTING CIRCUIT SHOWN. TELEPHONE OUTLET 1. PROVIDE LAMPS FOR EACH FIXTURE OF QUANTITY, TYPE AND COLOR AS LISTED IN LIGHTING FIXTURE SCHEDULE. GE, SYLVANIA OR PHILIPS ARE ACCEPTABLE. 9. ALL RACEWAY AND EQUIPMENT SUPPORTS AND HANGERS SHALL BE FULLY COORDINATED WITH STRUCTURAL DRAWINGS. THE LINES INDICATING BRANCH CIRCUITS DO NOT REPRESENT THE ROUTING OF ELECTRICAL CONDUITS. THEY INDICATE THE LAYOUT AND CONTROL OF CIRCUITS. EACH LIGHTING FIXTURE SHALL BE UL LABELED FOR PROPER OPERATION IN THE TYPE OF CEILING CONSTRUCTION AND FOR THE MOUNTING ARRANGEMENT ON/IN WHICH IT IS INSTALLED. PRODUCTS AND WORK FIELD VERIFY ACTUAL CEILING SLOPE FOR FIXTURES INSTALLED IN SAME AND ACTUAL FIELD DIMENSIONS AND ANGLES OF CONSTRUCTION FOR ANY FIXTURE CONFORMING THE SHAPE AND LENGTH OF SAME, FOR COORDINATION OF FIXTURE CONSTRUCTION. SCHEDULE BY TYPE DESIGNATION ALL LIGHTING FIXTURES, EACH COMPLETE WITH DATA SHEET WITH COMPLETE PHYSICAL, ELECTRICAL AND LIGHTING CHARACTERISTICS, LAMP TYPE AND LAMP DATA. 10. M XX-# LIGHTING CONTROL MANUFACTURERS: SQUARE D, B-LINE, ALLIED TUBE & CONDUIT, HOFFMAN, CARLON ELECTRICAL, WIREMOLD. TIME SWITCHES: ALLOW CONNECTION OF A PHOTOELECTRIC RELAY AS SUBSTITUTE FOR ON-OFF FUNCTION OF A PROGRAM ISSUED FOR BID SEAL: 02.07.2014 PROJECT NAME & ADDRESS IG ISOLATED GROUND REFER TO THE ARCHITECTURAL/INTERIORS DOCUMENTS FOR ACTUAL DEVICE LOCATIONS AND DIMENSIONS. FIELD VERIFY LAYOUT WITH EXISTING CONDITIONS AND STRUCTURE PRIOR TO BEGINNING INSTALLATION. AF AMP FUSE ISC SHORT CIRCUIT CURRENT 12. SEE HVAC DRAWINGS FOR LOCATIONS OF EQUIPMENT TO BE POWERED. AFF ABOVE FINISHED FLOOR LTG LIGHTING 13. COORDINATE WITH EQUIPMENT CUTSHEETS AND PROVIDE ADDITIONAL CONTROL CIRCUITS IF REQUIRED BY MANUFACTURER. AL ALUMINUM MTD MOUNTED 14. GENERAL DIAGRAMMATIC RACEWAY INTERCONNECTIONS OF EQUIPMENT, FIXTURES AND DEVICES ARE INDICATED ON FLOOR AND REFLECTED CEILING PLANS, REFER TO STRUCTURAL AND ARCHITECTURAL PLANS FOR ELEVATION CHANGES AND RACEWAY ROUTES. BFC BELOW FINISHED CEILING N NEUTRAL BKR BREAKER NL NIGHT LIGHT CND CONDUIT NEC NATIONAL ELECTRICAL CODE CONN CONNECTED OR CONNECTION PNL PANEL CTB CABLE TV TERMINAL BACKBOARD RECPT RECEPTACLE CU COPPER TEL TELEPHONE DN DOWN TTB TELEPHONE TERMINAL BOARD EC EMPTY CONDUIT TV TELEVISION ELEC ELECTRICAL TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR FACP FIRE ALARM CONTROL PANEL TYP TYPICAL PROTOTYPE SERIES FAA FIRE ALARM ANNUNCIATOR PANEL XFMR TRANSFORMER 70 SL (C) - SDT G OR GRND GROUND UG UNDERGROUND SHEET TITLE: GFCI OR GF GROUND FAULT CIRCUIT INTERRUPTER WP WEATHERPROOF 11. 15. PROVIDE SURGE PROTECTION FOR ELECTRICAL AND TELEPHONE SERVICES. 16. EACH PENETRATION OF A FIRE RESISTANT RATED ASSEMBLY BY A PIPE, TUBE WIRE OR CONDUIT SHALL BE PROTECTED BY A THROUGH PENETRATION FIRE STOP SYSTEM THAT HAS BEEN TESTED ACCORDING TO ASTM E814 OR E199. 17. ELECTRIC RECEPTACLES, SWITCHES, OUTLETS, ETC. SHALL NOT BE INSTALLED BACK TO BACK ON FIRE RESISTANCE RATED WALLS. THEY SHALL BE AT LEAST 24-INCHES APART. SOLID STATE, PROGRAMMABLE, WITH ALPHANUMERIC DISPLAY; COMPLYING WITH UL 917. 20-A BALLAST LOAD, 120/240VAC. TWO ON-OFF SET POINTS ON A 24-HOUR SCHEDULE AND ANNUAL HOLIDAY SCHDULE THAT OVERRIDES THE WEEKLY OPERATION ON HOLIDAYS. ISSUED FOR PERMIT 02-07-14 6" ABOVE COUNTER SPACE OR 42" AFF ALL JUNCTION BOXES SHALL BE LABELED WITH PANEL AND CIRCUIT DESIGNATION. APPROVED MANUFACTURERS: GENERAL ELECTRIC CUTLER HAMMER SQUARE D SIEMENS DESCRIPTION: 02-07-14 AC LABELED PER UL #67 AND #50, CONFORM WITH NEMA #250 AND PB1, NFPA #70-384 AND 70-373. PROVIDE TYPED CIRCUIT DIRECTORY WITH EACH CIRCUIT SERVING DEVICES AND AREA IT'S SERVING. ISSUE / REVISIONS: DATE HOME RUN WITH WIRE TICKS. XX - PANEL DESIGNATION, # - CIRCUIT DESIGNATION. WIRE TICKS - (1) NEUTRAL , (3) HOT & (1) GROUND SUBMITTAL: INCLUDE SCHEDULE OF EACH PANELBOARD WITH ALL DEVICES AND COMPLETE WITH PHYSICAL AND ELECTRICAL DATA AND WITH RATINGS FOR EACH COMPONENT INCLUDING BREAKER/FUSE OVERLAY CURVES. ISSUED FOR CONSTRUCTION MOTOR ABBREVIATIONS REFER TO THE ARCHITECTURAL/INTERIORS REFLECTED CEILING PLANS FOR EXACT FIXTURE PLACEMENT AND DIMENSIONS. PANELBOARD CONDUITS AND RACEWAYS: OUTDOORS EXPOSED: RIGID STEEL. OUTDOORS CONCEALED ABOVE GROUND: RIGID STEEL. OUTDOORS UNDERGROUND: TYPE EPC-40-PVC OUTDOORS CONNECTION TO VIBRATING EQUIPMENT (INCLUDING TRANSFORMERS AND MOTOR DRIVEN EQUIPMENT): LFMC. BOXES AND ENCLOSURES ABOVE GROUND: NEMA 3R UNLESS NOTED OTHERWISE ON PLANS. INDOORS EXPOSED NOT SUBJECT TO PHYSICAL DAMAGE: EMT. INDOORS EXPOSED NOT SUBJECT TO SEVERE PHYSICAL DAMAGE: EMT. INDOORS EXPOSED SUBJECT TO SEVERE PHYSICAL DAMAGE: RIGID STEEL CONDUIT. INDOORS CONCEALED IN CEILINGS AND INTERIOR WALLS AND PARTITIONS: EMT. INDOORS CONNECTION TO VIBRATING EQUIPMENT: FMC, EXCEPT USE LFMC IN DAMP OR WET LOCATIONS. INDOORS DAMP OR WET LOCATIONS: IMC. INDOORS LOW-VOLTAGE CABLES: EMT. 48" AFF OR 6" ABOVE COUNTER TOP IN CEILING WALL SWITCHES CONTROLLING CIRCUITS OF OPPOSITE PHASES SHALL NOT BE INSTALLED IN COMMON BOX UNLESS PERMANENT BARRIER IS PROVIDED. COORDINATE THE WORK UNDER THIS SECTION WITH ALL OTHER TRADES. QUADRAPLEX RECEPTACLE, 120V, 20A, NEMA 5-20R JUNCTION BOX FLUSH IN CEILING WITH COVER. SIZE PER NEC. 8. ALL HORIZONTAL RUNS OF CONDUITS SHALL BE SUPPORTED BY MEANS OF APPROVED HANGER FROM THE STRUCTURAL CEILING. 18" AFF J ELECTRICAL DEVICES ARE INDICATED ON DRAWINGS AT APPROXIMATE LOCATIONS. THE OWNER RESERVE THE RIGHT TO MAKE REASONABLE CHANGES IN LOCATIONS WITHOUT ADDITIONAL COSTS. COMPLETE CATALOGUE ILLUSTRATION AND DESCRIPTIONS OF ALL EQUIPMENT SHALL BE SUBMITTED TO THE OWNER PRIOR TO ORDERING ANY EQUIPMENT. QUADRAPLEX RECEPTACLE, 120V, 20A, NEMA 5-20R MANUFACTURERS: CUTLER-HAMMER, SIEMENS, GE AND SQUARE D. REFER TO THE "LIGHTING FIXTURE SCHEDULE" \IN THE DRAWINGS FOR INDIVIDUAL FIXTURE DESCRIPTIONS AND MANUFACTURER TYPES. CONTRACTOR SHALL MAKE CERTAIN THAT ALL EQUIPMENT FIT IN THE SPACE DESIGNATED AND DESIGNED FOR THE SURROUNDINGS IT OCCUPIES. 48" AFF OR 6" ABOVE COUNTER TOP 18" AFF EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSTALLED IN ALL RACEWAYS. CONTRACTOR SHALL NOT INTERPRET THAT THE LISTED MANUFACTURERS IN SPECIFICATIONS OR DRAWINGS TO EXCLUDE ALL OTHER MANUFACTURERS DUPLEX RECEPTACLE, 120V, 20A, NEMA 5-20R JUNCTION BOX FLUSH IN WALL WITH COVER. SIZE PER NEC. 7. LISTED MANUFACTURERS, MODELS, OR CATALOGUE NUMBERS IN PART OR ALL SHALL ENTAIL TO INCLUDE THE PUBLISHED MANUFACTURER'S DESCRIPTION AND SPECIFICATION. 18" AFF J REFER TO APPROPRIATE DRAWINGS AND MANUFACTURER'S INSTALLATION MANUAL TO PROVIDE ALL SUPPLEMENTARY AND CONTROL CIRCUITS TO BRING EQUIPMENT TO FULL WORKING CONDITION. MATERIALS FURNISHED SHALL BE NEW AND BY STANDARD MANUFACTURERS AND MUST CONFORM TO THE NATIONAL BOARD OF FIRE UNDERWRITER'S REQUIREMENTS AND BEAR THE UNDERWRITER'S LABORATORIES' SEAL OF APPROVAL. DUPLEX RECEPTACLE, 120V, 20A, NEMA 5-20R PROVIDE CERTIFICATION THAT TRANSFORMERS, ACCESSORIES, AND COMPONENTS WILL WITHSTAND SEISMIC FORCES. 6. CONTRACTOR SHALL COORDINATE AND VERIFY THE WORK WITH EXISTING CONDITIONS AND THE WORK OF OTHER TRADE PRIOR TO ANY FABRICATIONS OR INSTALLATION. IF THE LAYOUT OF THE DEVICES ON DRAWINGS ARE IMPRACTICAL TO THE CONDITION IN FIELD, CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY PRIOR TO ANY FABRICATION OR INSTALLATION. AC INSTALL INSULATED EQUIPMENT GROUNDING CONDUCTORS FOR ALL EQUIPMENT. LIGHTING FIXTURE ANY EXCEPTIONS, INCONSISTENCIES AND CONFLICTS IN CONTRACT DOCUMENTS, SPECIFICATIONS AND CONTRACT DOCUMENTS BY OTHER TRADE SHALL BE BROUGHT TO ATTENTION TO THE OWNER PRIOR TO BID. peiatl.com LOW VOLTAGE TRANSFORMERS ACCEPTABLE MANUFACTURERS OF CONDUCTORS: PIRELLIE SOUTHWIRE AETNA REPUBLIC AFC ENCORE WIRE KERITE ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH LOCAL, COUNTY, STATE, AND NATIONAL ELECTRICAL CODE 2011, SPECIFICATIONS, UTILITY COMPANY REQUIREMENTS AND ALL INDUSTRY STANDARDS. MOUNTING R ALL INSTALLATION OF DEVICES AND CONNECTION OF CONDUCTORS SHALL BE PERFORMED BY LICENSED AND SKILLED ELECTRICIAN OR JOURNEYMAN. DESCRIPTION SEISMIC NOTES 1. ALL ELECTRICAL DISTRIBUTION EQUIPMENT ARE RATED IMPORTANCE FACTOR OF 1.0. BATTERY BACKUP FOR NOT LESS THAN SEVEN DAYS RESERVE TO MAINTAIN SCHEDULES AND TIME CLOCK. 2. ALL EQUIPMENT MOUNTED BELOW 4'-0" AFF IS EXEMPT FROM SEISMIC REQUIREMENT PER ASCE 13.1.4. INDOOR OCCUPANCY SENSORS: 3. SEISMIC LATERAL FORCE OF ALL DISTRIBUTION EQUIPMENT MOUNTED ABOVE 4'-0" AFF SHALL BE DETERMINED FROM FINAL WEIGHT OF EACH EQUIPMENT MULTIPLIED BY 0.34 AND CONFIRM WITH THE MANUFACTURER THE INTEGRITY OF EACH EQUIPMENT SHALL MEET THE REQUIREMENT. THE MOUNTING OF EACH EQUIPMENT SHALL MEET MINIMUM SEISMIC LATERAL FORCE REQUIREMENT. 4. LIGHTING FIXTURES ARE EXEMPT FROM SEISMIC REQUIRED ANCHORAGE PRESCRIBE IN ASCE 13.4, PROVIDED FINAL DESIGN LOAD IS EQUAL TO 1.4 TIMES THE OPERATING WEIGHT ACTING DOWN WITH A SIMULTANEOUS HORIZONTAL LOAD EUAL TO 1.4 TIMES THE OPERATING WEIGHT. HORIZONTAL LOAD SHALL BE APPLIED IN THE DIRECTION AT RESULTS IN THE MOST CRITICAL LOADING FOR DESIGN. WALL OR CEILING MOUNTED SOLID-STATE INDOOR OCCUPANCY SENSORS WITH A SEPARATE POWER PACK 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH THE WORK UNDER THIS SPECIFICATIONS AND DRAWINGS SHALL INCLUDE ALL LABOR. N E GENERAL R G (CONTINUED) P SPECIFICATIONS F I C I E T SPECIFICATIONS O SPECIFICATIONS, NOTES, ABBREAVIATIONS & SYMBOLS ADJUSTABLE TIME-DELAY OVER A RANGE OF 1 TO 30 MINUTES. SENSOR OUTPUT: CONTACTS RATED TO OPERATE THE CONNECTED RELAY, COMPLYING WITH UL773A. SENSOR IS POWERED FROM POWER PACK. POWER PACK: DRY CONTACTS RATED FOR 20-A BALLAST LOAD AT 120 OR 277 VAC. AUTOMATIC LIGHT-LEVEL SENSOR: ADJUSTABLE FROM 2 TO 200 FC (21.5 TO 2152 LUX); TURN LIGHTS OFF WHEN SELECTED LIGHTING LEVEL IS PRESENT. 5. DUAL SENSOR TYPE: DETECT OCCUPANCY AREA USING PIR (PASSIVE INFRA-RED) AND ULTRASONIC DETECTION METHOD. 6. PROJECT #: 14-820.00 WHEN INSTALLING LIGHTING FIXTURES, SEISMIC INTERACTION EFFECTS SHALL BE CONSIDERED IN ACCORDANCE WITH ASCE 13.2.3. IN THE HORIZONTAL PLANE. E000 R O F I C I E N P T FUSED SERVICE DISCONNECT SWITCH KITCHEN EQUIPMENT SCHEDULE WIRE CALLOUT DISCONNECT DESCRIPTION 1 CASH REGISTER 120V 1P 2W 0.18 PV-1 1/2"C,1#10,#10N,#10G,#10IG GFCI NEMA 5-20R 45" AFF 1 CASH REGISTER 120V 1P 2W 0.18 PV-1 1/2"C,1#12,#12N,#12G,#12IG GFCI NEMA 5-20R 45" AFF 1 CASH REGISTER 120V 1P 2W 0.18 PV-3 1/2"C,1#12,#12N,#12G,#12IG GFCI NEMA 5-20R 45" AFF 1 CASH REGISTER 120V 1P 2W 0.18 PV-3 1/2"C,1#12,#12N,#12G,#12IG GFCI NEMA 5-20R 45" AFF 1 CASH REGISTER 120V 1P 2W 0.18 PV-3 1/2"C,1#12,#12N,#12G,#12IG GFCI NEMA 5-20R 45" AFF 2 HOLDING/PROOF CABINET 120V 1P 2W 2.23 B-5 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 24" AFF 4 SODA DISPENSOR - DINING RM 120V 1P 2W 1.44 B-24 1/2"C,1#10,#10N,#10G GFCI NEMA 5-20R 66" AFF 4 SODA DISPENSOR - DRIVE THRU 120V 1P 2W 1.44 B-26 1/2"C,1#10,#10N,#10G GFCI NEMA 5-20R 48" AFF 4F SODA DISPENSOR - DINING RM 120V 1P 2W 1.44 B-28 1/2"C,1#10,#10N,#10G GFCI NEMA 5-20R 66" AFF 8 REACH-IN FREEZER 120V 1P 2W 1.08 B-30 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R CEILING MOUNTED 9 SAND TOP REFRIG COUNTER 120V 1P 2W 0.84 LOAD CENTER 9 SAND TOP REFRIG COUNTER 120V 1P 2W 0.84 LOAD CENTER 9.1 CENTERLINE TABLE 208V 3P 4W 36.03 MDP-6 1-1/4"C,3#2,#2N,#8G BREAKER IN LOADCENTER 10 PIZZA PREP REFRIGERATOR 120V 1P 2W 1.2 B-3 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 30" AFF 11 DEEP FAT FRYER (PITCO) 120V 1P 2W 0.08 C-3 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 30" AFF 120V 1P 2W 0.08 C-3 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 30" AFF 11 DEEP FAT FRYER (PITCO) 120V 1P 2W 0.08 C-3 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 30" AFF DEEP FAT FRYER (PITCO) 120V 1P 2W 0.08 C-3 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 30" AFF 11 DEEP FAT FRYER (PITCO) 120V 1P 2W 0.08 C-3 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 30" AFF 11 DEEP FAT FRYER (PITCO) 120V 1P 2W 0.08 C-3 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 30" AFF 11.4 ELECTRONIC TIMER 120V 1P 2W 0.01 C-5 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 11.4 ELECTRONIC TIMER 120V 1P 2W 0.01 C-5 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 11.4 ELECTRONIC TIMER 120V 1P 2W 0.01 C-5 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 12 DOUBLE SIDED GRILL (STAR) 208V 2P 2W 2.7 C-21,23 1/2"C,2#12,#12G GFCI NEMA 6-20R 30" AFF 12 DOUBLE SIDED GRILL (STAR) 208V 2P 2W 2.7 C-25,27 1/2"C,2#12,#12G GFCI NEMA 6-20R 30" AFF 13 REFRIGERATED COUNTER 120V 1P 2W 2.08 C-15,17,19 1-1/4"C,3#4,#4N,#8G GFCI NEMA 5-20R 30" AFF 14 GRIDDLE 208V 3P 3W 18.48 C-15,17,19 1-1/4"C,3#4,#4N,#8G 30A/3P/NEMA1 30" AFF 17 SODA SYSTEM 120V 1P 2W 0.84 B-41 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 48" AFF 17 SODA SYSTEM 120V 1P 2W 0.84 B-41 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 48" AFF 20.1 ICE MAKER 208/120V 2P 3W 1.68 B-34,36 1/2"C,2#10,#10N,#10G 30A/2P/NEMA 1 78" AFF 20.1F ICE MAKER 208/120V 2P 3W 1.68 B-38,40 1/2"C,2#10,#10N,#10G 30A/2P/NEMA 1 78" AFF 20.2 ICE MAKER 208/120V 2P 3W 1.68 B-10,12 1/2"C,2#12,#12N,#12G 30A/2P/NEMA 1 78" AFF 20.2 ICE MAKER 208/120V 2P 3W 1.68 B-14,16 1/2"C,2#12,#12N,#12G 30A/2P/NEMA 1 78" AFF 20.4 REMOTE CONDENSER 208/120V 2P 3W 0.1 D-16,18 1/2"C,2#10,#10N,#10G 30A/2P/NEMA3R/15AF 20.4 REMOTE CONDENSER 208/120V 2P 3W 0.1 D-20,22 1/2"C,2#12,#12N,#12G C D POWERVAR UPS 1.5 KVA T 1.66 D-24,26,28 1/2"C,3#12,#12G 30A/1P/NEMA3R 23B KEF-2 208V 3P 3W 1.66 D-30,32,34 1/2"C,3#12,#12G 30A/1P/NEMA3R 26 FIRE SUPPRESSION SYSTEM 120V 1P 2W 0.5 B-1 1/2"C,1#12,#12N,#12G 34 AIR CURTAIN 120V 1P 2W 0.9 B-39 1/2"C,1#12,#12N,#12G 40 HOLDING BIN 120V 1P 2W 1 BREAKER IN LOADCENTER 40.2 DROP IN - HEATED SHELF 120V 1P 2W 1 BREAKER IN LOADCENTER 40.3 OVERHEAD FOOD WARMER 120V 1P 2W 1 BREAKER IN LOADCENTER 40.3 OVERHEAD FOOD WARMER 120V 1P 2W 1 BREAKER IN LOADCENTER 40.4 REMOTE CONTROL SWITCH ENCLOSURE 120V 1P 2W 1 BREAKER IN LOADCENTER 40.4 REMOTE CONTROL SWITCH ENCLOSURE 120V 1P 2W 1 BREAKER IN LOADCENTER 42 ICE TEA MAKER 120V 1P 2W 1.92 B-6 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 45" AFF 42 ICE TEA MAKER 120V 1P 2W 1.92 B-8 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 45" AFF 44 OTIS SPUNK COOKIE HEATER 120V 1P 2W 1.36 B-4 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 45" AFF 49 WALK-IN COOLER (LTS & DOOR HTR) 120V 1P 2W 0.72 B-35 1/2"C,1#12,#12N,#12G (2) SWITCHES 49A WALK-IN COOLER CONDENSER 208V 3P 4W 5.22 B-23,25,27 1/2"C,3#12,#12N,#12G 30A/3P/NEMA3R/15AF 49B WALK-IN COOLER EVAPORATOR 208V 3P 3W 0.36 B-7,9,11 1/2"C,3#12,#12G DISCONNECT VIA 49A 50 WALK-IN FREEZER (LTS & DOOR HTR) 120V 1P 2W 0.72 B-37 1/2"C,1#12,#12N,#12G (2) SWITCHES 50A WALK-IN FREEZER CONDENSER 208V 3P 4W 10.38 B-29,31,33 1/2"C,3#10,#10N,#10G 60A/3P/NEMA3R/30AF 50B WALK-IN FREEZER EVAPORATOR 208V 3P 3W 0.36 B-13,15,17 1/2"C,3#12,#12G DISCONNECT VIA 50A SEE ONE-LINE DIAGRAM ON THIS SHEET AND FAULT CURRENT SCHEDULE ON E003 FOR AIC RATING. (1) 1-1/4" EMPTY CONDUITS W/PULLWIRE FOR LIFT STATION PROVIDED BY OTHERS. COORDINATE EXACT LOCATION WITH CIVIL PLANS. RISER DIAGRAM N.T.S. BUILDING SPRINKLER CONNECTION, IF REQ'D. (NOT IN F.S.E.C. CONTRACT) ISSUED FOR CONSTRUCTION CONDUIT DOWN THRU WALK-IN TOP TO JUNCTION BOX ON EVAPORATOR COIL. PROVIDE DISCONNECT SWITCH (EXPOSED CONDUIT ACCEPTABLE FOR THIS CONDITION) ISSUE / REVISIONS: GENERAL NOTES CONDUIT DOWN WITH OUTLET FOR DRAINLINE HEATER OR MAINTENANCE OUTLET EXPOSED CONDUIT FOR THIS CONDITION IS ACCEPTABLE) DATE FOR 2/E001 ONLY ELECTRICAL CONTRACTOR SHALL MOUNT LIGHT FIXTURES, RUN CONDUIT DOWN THRU WALK-IN TOP INTO FIXTURE(S), SEE ELECTRICAL ROUGH-IN PLAN FOR THE NUMBER AND LOCATION OF REQUIRED LIGHT FIXTURES 1. ALL INTERCONNECTING CONDUIT SHALL BE RUN ABOVE WALK-IN OR BUILT-IN THE WALL PANELS, EXPOSED CONDUIT WILL NOT BE ACCEPTABLE EXCEPT FOR THE CONDITIONS SHOWN AND NOTED IN THE ABOVE ILLUSTRATION 2. SEAL ALL PENETRATIONS THRU WALK-IN TOP, WALL PANELS AND INSIDE ELECTRICAL CONDUIT WITH THERMAL MASTIC 3. PROVIDE HOLE FOR SPRINKLER HEAD (IF REQUIRED) AND AFTER INSTALLATION SEAL WITH THERMAL MASTIC ELECTRICAL CONTRACTOR SHALL WIRE ALL WALK-IN ELECTRICAL COMPONENTS EXCEPT BLOWER COILS TO THIS JUNCTION BOX PROJECT NAME & ADDRESS WALK-IN COOLER DETAIL N.T.S. UTILITY TRANSFORMER (2)4"C, 4#500kcmil M UTILITY METER SERVICE DISCONNECT: DSC 208Y/120V 3P 4W FRAME: 800 FUSE: 800 AMPS FAULT: 30,190 AMPS AIC: 100,000 AMPS (2)4"C, 3#500kcmil, #500kcmil N, #2/0G ST PANEL: MDP 208Y/120V 3P 4W BUS AMP: 800 MAIN: MLO FAULT: 27,423 AMPS DEMAND LOAD: 165 KVA AIC: 42,000 AMPS PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: UNDERCOUNTER FREEZER 120V 1P 2W 0.7 B-20 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 24" AFF 52 FROZEN DESSERT MACHINE 120V 1P 2W 0.31 B-18 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 48" AFF 52 FROZEN DESSERT MACHINE 120V 1P 2W 0.31 B-22 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 48" AFF 54F CONVECTION OVEN (FUTURE) 208/120V 2P 3W 5.62 C-7,9 1/2"C,2#10,#10N,#10G 60A/2P/NEMA1 30" AFF 54F CONVECTION OVEN (FUTURE) 208/120V 2P 3W 5.62 C-11,13 1/2"C,2#10,#10N,#10G 60A/2P/NEMA1 30" AFF 56 GREASE RECOVERY SYSTEM 120V 1P 2W 1.44 B-2 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R 48" AFF 120V 1P 2W 1.14 B-42 1/2"C,1#12,#12N,#12G GFCI NEMA 5-20R ISSUED FOR BID JUNCTION BOX AND CONDUIT BUILT IN WALL PANEL FOR DOOR HEATER TIME CLOCK FOR ELECTRICAL DEFROST OF FREEZER BLOWER COILS AND OFF-CYCLE DEFROST OF REFRIGERATOR BLOWER COILS (MOUNT IN EASILY ACCESSIBLE LOCATION) 90" AFF 51 REACH-IN REFRIGERATOR ISSUED FOR PERMIT 02-07-14 SEAL: 02.07.2014 ELECTRICAL CONTRACTOR SHALL INTERWIRE TIME CLOCK AND EVAPORATOR BLOWER COILS THRU THIS JUNCTION BOX 3"C, 3#500kcmil, #500kcmil N, #2G 58 DESCRIPTION: 02-07-14 JUNCTION BOXES AND CONDUIT BUILT IN WALL PANEL FOR LIGHT SWITCH AND THERMOMETER E001 208V 3P 3W p 404.330.9798 www.peiatl.com TO PV CIRCUITS 2 KEF-1 Suite 140 R HEATED PRESSURE RELIEF PORT ON FREEZERS 23A N I N E E R I Atlanta, Georgia 30340 FOR 1/E001 ONLY 1. G 3600 Dekalb Technology Pkwy GENERAL NOTES POWERVAR LAPC 30A/2P/NEMA3R/15AF SWITCH B N E001 DEEP FAT FRYER (PITCO) A POWER COMPANY METER AND CT CAN. UTILITY POWER CO. TRANSFORMER 1 11 11 MDP NOTE 1 G CIRCUIT R KVA VOLTS 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH CUSTOM PANEL DESCRIPTION E CALLOUT peiatl.com CEILING MOUNTED 2-1/2"C, 3#4/0, #4/0N, #4G ONE-LINE & RISER DIAGRAM 1-1/4"C, 3#2, #2N, #8G 1/2"C, 1#8, #8N, #10G PANEL: A 208Y/120V 3P 4W BUS AMP: 225 MAIN: MLO FAULT: 23,981 AMPS DEMAND LOAD: 49.7 KVA AIC: 42,000 AMPS UPS: PV 120V 1P 2W DEMAIND LOAD: 2.34 PANEL: D 208Y/120V 3P 4W BUS AMP: 100 MAIN: MLO FAULT: 16,617 AMPS DEMAND LOAD: 14.1 KVA AIC: 22,000 AMPS PANEL: B 208Y/120V 3P 4W BUS AMP: 100 MAIN: MLO FAULT: 20,022 AMPS DEMAND LOAD: 29.9 KVA AIC: 22,000 AMPS PANEL: C 208Y/120V 3P 4W BUS AMP: 400 MAIN: MLO FAULT: 23,949 AMPS DEMAND LOAD: 26 KVA AIC: 42,000 AMPS PROJECT #: 14-820.00 1-1/4"C, 3#2, #2N, #8G 3 E001 ONE-LINE DIAGRAM N.T.S. E001 B ROOM VOLTS MOUNTING SURFACE BUS AMPS FED FROM NEUTRAL MDP 208Y/120V 3P 4W AIC 42,000 225 MAIN BKR 100% LUGS MLO FEEDTHRU NOTE R VOLTS MOUNTING SURFACE BUS AMPS FED FROM NEUTRAL MDP 208Y/120V 3P 4W AIC 22,000 100 MAIN BKR 100% LUGS MLO peiatl.com STANDARD NOTE 1.0 LIGHTING SIGNAGE UPS PV LIGHTING LIGHTING LIGHTING LIGHTING RECEPTACLE CEILING FAN LIGHTING LIGHTING LIGHTING HOOD LIGHT SIGNAGE DRIVE THRU MENU LIGHTING 1.2 2.3 0.3 0.1 0.7 0.2 0.2 0.4 0.2 0.1 0.6 1.0 1.2 1.2 0.3 0.3 0.6 LIGHTING 0.6 1.2 SIGNAGE SIGNAGE 1.2 LUG LOAD: PANEL D 5.9 CONN. KVA LIGHTING LARGEST MOTOR OTHER MOTORS RECEPTACLES 15.3 7.7 6.5 10.8 4.1 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 30/3 | | 20/3 | | 15/1 20/2 | 20/1 20/2 | 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/2 | C 2.6 MAU-COND1 2.6 2.6 1.3 MAU-COND2 1.3 1.3 MAU-CTR LIGHTING 0.6 SIGNAGE LIGHTING 1.2 0.6 0.6 0.4 0.4 0.0 SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 5.1 TOTAL CONNECTED KVA BY PHASE CALC. KVA 19.1 9.6 6.5 10.4 A CIRCUIT DESCRIPTION KVA LOAD B N CONN. KVA (125%) (125%) (100%) (50%>10) CONTINUOUS HEATING NONCONTINUOUS KITCHEN EQUIP NONCOIN/DIVERSE TOTAL KVA 13.3 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 0.0 0.0 1.8 2.3 0.0 49.7 0.5 FIRE SUPPRESSION SYSTEM PIZZA PREP REFRIGERATOR HOLDING/PROOF CABINET WALK-IN COOLER EVAPORATOR 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 1.2 2.2 0.1 0.1 0.1 0.1 WALK-IN FREEZER EVAPORATOR 0.1 0.1 0.0 SPACE DOOR CHIME WALK-IN COOLER CONDENSER 0.2 1.7 1.7 1.7 3.5 WALK-IN FREEZER CONDENSER 3.5 3.5 0.7 WALK-IN COOLER (LTS & DOOR HTR) WALK-IN FREEZER (LTS & DOOR HTR) AIR CURTAIN SODA SYSTEM 0.7 0.9 1.7 A CIRCUIT DESCRIPTION 20/1 20/1 20/1 20/1 20/2 | 20/2 | 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/2 | 20/2 | 20/1 GREASE RECOVERY SYSTEM OTIS SPUNK COOKIE HEATER ICE TEA MAKER ICE TEA MAKER ICE MAKER 1.4 ICE MAKER 0.8 CONN. KVA (125%) (100%) (100%) LIGHTING LARGEST MOTOR OTHER MOTORS RECEPTACLES (65%) (N/A) 0.0 0.0 0.0 0.2 G N I N E E R I C 3600 Dekalb Technology Pkwy Suite 140 1.4 Atlanta, Georgia 30340 1.9 p 404.330.9798 1.9 www.peiatl.com 0.8 0.8 R 0.3 FROZEN DESSERT MACHINE UNDERCOUNTER FREEZER FROZEN DESSERT MACHINE SODA DISPENSOR - DINING RM SODA DISPENSOR - DRIVE THRU SODA DISPENSOR - DINING RM REACH-IN FREEZER RECEPTACLE ICE MAKER 0.7 0.3 1.4 1.4 1.4 1.1 0.2 0.8 0.8 0.8 ICE MAKER 0.8 1.1 REACH-IN REFRIGERATOR CONN. KVA (125%) (125%) (100%) (50%>10) CONTINUOUS HEATING NONCONTINUOUS KITCHEN EQUIP NONCOIN/DIVERSE TOTAL KVA 138.0 G 0.8 CALC. KVA 0.0 0.0 0.0 0.2 KVA LOAD B 14.2 17.6 CALC. KVA 0.0 0.0 0.2 45.5 0.0 45.9 BALANCED THREE PHASE AMPS 14 0.0 0.0 0.2 29.6 0.0 29.9 ISSUED FOR CONSTRUCTION (125%) (100%) (100%) ISSUE / REVISIONS: DATE (65%) (N/A) DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID 83.1 D ROOM VOLTS MOUNTING SURFACE BUS AMPS FED FROM NEUTRAL 20/1 20/1 20/1 30/2 | 30/2 | 70/3 | | 20/2 | 20/2 | 20/1 20/1 20/1 20/1 20/1 20/1 20/1 C CKT CKT # BKR TOTAL CONNECTED KVA BY PHASE MDP 208Y/120V 3P 4W AIC 42,000 400 MAIN BKR 100% LUGS MLO STANDARD NOTE 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 20/1 20/1 20/1 20/3 | | 20/3 | | 20/1 20/1 20/3 | | 30/3 | | 20/1 20/1 20/1 20/1 KVA LOAD B 17.1 C CKT CKT # BKR A CIRCUIT DESCRIPTION CALC. KVA 0.0 0.0 1.8 3.5 0.0 45.6 BALANCED THREE PHASE AMPS 15.2 CKT CKT # BKR ROOM VOLTS MOUNTING SURFACE BUS AMPS FED FROM NEUTRAL A 208Y/120V 3P 4W AIC 22,000 100 MAIN BKR 100% LUGS MLO STANDARD NOTE A CIRCUIT DESCRIPTION KVA LOAD B C 0.2 RECEPTACLE DEEP FAT FRYER (PITCO) HOOD LIGHTS, ELECTRONIC TIMER CONVECTION OVEN (FUTURE) 0.5 1.0 2.8 2.8 2.8 CONVECTION OVEN (FUTURE) 2.8 8.2 GRIDDLE, REFRIGERATED COUNTER 6.2 6.2 1.4 DOUBLE SIDED GRILL (STAR) 1.4 1.4 DOUBLE SIDED GRILL (STAR) 1.4 0.0 SPACE SPACE SPACE SPACE SPACE SPACE SPACE 0.0 0.0 0.0 0.0 0.0 0.0 CKT CKT # BKR 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 A CIRCUIT DESCRIPTION 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 LIGHTING LARGEST MOTOR OTHER MOTORS RECEPTACLES 1.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 CALC. KVA 1.3 0.0 0.0 0.2 CONN. KVA (125%) (125%) (100%) (50%>10) C 0.0 SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE TOTAL CONNECTED KVA BY PHASE CONN. KVA KVA LOAD B CONTINUOUS HEATING NONCONTINUOUS KITCHEN EQUIP NONCOIN/DIVERSE TOTAL KVA BALANCED THREE PHASE AMPS 13.3 14.3 CKT CKT # BKR 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 0.0 0.0 0.0 37.7 0.0 38.9 0.0 0.0 0.0 24.5 0.0 26.0 KVA LOAD B C 0.2 HVAC CONTROL PANEL RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE SPACE SPACE TEL BACKBOARD RECEPTACLE WH-2 CONTROL, WH-1 CONTROL WHRP-1 SPACE SPACE SPACE EF-1 SPACE CKT CKT # BKR 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 0.7 0.5 0.4 0.5 0.5 0.7 0.7 1.1 0.9 0.0 0.0 1.0 0.2 1.1 0.5 0.0 0.0 0.0 0.5 0.0 A CIRCUIT DESCRIPTION 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/2 | 20/2 | 20/3 | | 20/3 | | 20/1 20/1 20/1 20/1 RECEPTACLE RECEPTACLE RECEPTACLE SPACE SPACE RECEPTACLE RECEPTACLE REMOTE CONDENSER 0.4 REMOTE CONDENSER 0.1 (125%) (100%) (100%) LIGHTING LARGEST MOTOR OTHER MOTORS RECEPTACLES (65%) (N/A) 0.0 1.1 1.1 8.3 0.4 0.0 0.4 0.7 0.1 0.1 0.6 0.6 0.6 0.6 KEF-2 PROJECT NAME & ADDRESS 0.6 0.6 0.0 SPACE SPACE SPACE SPACE 0.0 0.0 0.0 CONN. KVA (125%) (125%) (100%) (50%>10) CONTINUOUS HEATING NONCONTINUOUS KITCHEN EQUIP NONCOIN/DIVERSE TOTAL KVA 72.1 SEAL: 02.07.2014 0.0 KEF-1 CALC. KVA 0.0 1.3 1.1 8.3 C 0.2 TOTAL CONNECTED KVA BY PHASE CONN. KVA KVA LOAD B 0.1 11.4 CALC. KVA BALANCED THREE PHASE AMPS PV 5.94 4.07 5.09 CALC. KVA 0.0 0.0 1.2 3.5 0.0 15.1 0.0 0.0 1.2 2.3 0.0 14.1 (125%) (100%) (100%) (65%) (N/A) 39.2 MDP ROOM VOLTS MOUNTING FLUSH BUS AMPS FED FROM NEUTRAL A 120V 1P 2W AIC 22,000 MAIN BKR 100% LUGS MLO STANDARD NOTE ROOM VOLTS MOUNTING SURFACE BUS AMPS FED FROM NEUTRAL DSC 208Y/120V 3P 4W AIC 42,000 800 MAIN BKR 100% LUGS MLO STANDARD NOTE KVA BREAKER LOAD A TRIP/POLES CKT # CIRCUIT DESCRIPTION 1 2 3 4 A CIRCUIT DESCRIPTION R 20/1 20/1 40/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/2 | 20/2 | 20/1 20/1 C CKT CKT # BKR 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 A CIRCUIT DESCRIPTION KVA LOAD B N P ROOM E CKT CKT # BKR F I C I E T A O 0.5 0.2 0.5 1.1 RECEPTACLE, CASH REGISTER RECEPTACLE CASH REGISTER RECEPTACLE TOTAL CONNECTED KVA BY PHASE CONN. KVA LIGHTING LARGEST MOTOR OTHER MOTORS RECEPTACLES 0.0 0.0 0.0 2.3 20/1 20/1 20/1 20/1 CKT # CIRCUIT DESCRIPTION COND. CU CU CU CU FEEDER RACEWAY AND CONDUCTORS 1/2"C,1#10,#10N,#10G,#10IG 1/2"C,1#12,#12N,#12G,#12IG 1/2"C,1#12,#12N,#12G,#12IG 1/2"C,1#12,#12N,#12G 2.34 CALC. KVA 0.0 0.0 0.0 2.3 (125%) (125%) (100%) (50%>10) CONN. KVA CONTINUOUS HEATING NONCONTINUOUS KITCHEN EQUIP NONCOIN/DIVERSE TOTAL KVA CALC. KVA 0.0 0.0 0.0 0.0 0.0 2.3 0.0 0.0 0.0 0.0 0.0 2.3 PHASE AMPS 19.5 (125%) (100%) (100%) (N/A) (N/A) 1 2 3 4 5 6 7 8 9 10 11 12 A SPACE PANEL A PANEL B PANEL C SHUNT TRIP ASSEMBLY CENTERLINE TABLE RTU-1 RTU-2 RTU-3 RTU-4 SPACE SPACE TOTAL CONNECTED KVA BY PHASE CONN. KVA LIGHTING LARGEST MOTOR OTHER MOTORS RECEPTACLES 16.3 9.3 40.5 11.2 KVA LOAD B C 0.0 15.2 14.0 13.3 0.0 12.0 3.1 3.1 2.8 2.8 0.0 0.0 0.0 13.3 14.2 14.3 0.0 12.0 3.1 3.1 2.8 2.8 0.0 0.0 0.0 17.1 17.6 11.4 0.0 12.0 3.1 3.1 2.8 2.8 0.0 0.0 66.4 65.7 70 BREAKER TRIP/POLES 20/3 225/3 100/3 400/3 /3 100/3 30/3 30/3 30/3 30/3 20/3 20/3 COND. CU CU CU CU CU CU CU CU CU CU CU CU CALC. KVA 20.3 11.7 40.5 10.6 (125%) (125%) (100%) (50%>10) FEEDER RACEWAY AND CONDUCTORS 2-1/2"C,3#4/0,#4/0N,#4G 1-1/4"C,3#2,#2N,#8G 3"C,3#500kcmil,#500kcmil N,#2G 1-1/4"C,3#2,#2N,#8G 1/2"C,3#10,#10N,#10G 1/2"C,3#10,#10N,#10G 1/2"C,3#10,#10N,#10G 1/2"C,3#10,#10N,#10G CONN. KVA CONTINUOUS HEATING NONCONTINUOUS KITCHEN EQUIP NONCOIN/DIVERSE TOTAL KVA 0.0 0.0 2.0 122.8 0.0 202.0 BALANCED THREE PHASE AMPS CALC. KVA 0.0 0.0 2.0 79.8 0.0 164.9 (125%) (100%) (100%) (65%) (N/A) 457.6 PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: SCHEDULES PROJECT #: 14-820.00 E002 R DEVICE FAULT AIC RATING F I C I E N P T FAULT CURRENT SCHEDULE O UTILITY L-N VOLTS FAULT FEEDER FED FROM X R FAULT DEVICE X SIZE R X / 1000' R / 1000' X LENGTH R TOTAL MOTOR DIRECTLY CONNECTED MOTOR LOAD KVA FAULT X peiatl.com R FAULT UTILITY 42,208 UTILITY 120V 41,659 0.002825 0.0005649 DSC 30,190 100,000 120V 29,638 0.003844 0.001271 UTILITY 41,659 0.002825 0.0005649 (2)#500kcmil 0.0195 0.0135 52'-3" 0.001 0.0007 552 MDP 27,423 42,000 120V 26,870 0.0042 0.001517 DSC 29,638 0.003844 0.001271 (2)#500kcmil 0.0195 0.0135 18'-3" 0.0004 0.0002 553 35.6 395 0.2946 0.07364 A 23,981 42,000 120V 23,521 0.004623 0.002157 MDP 26,870 0.0042 0.001517 #4/0 0.041 0.062 10'-4" 0.0004 0.0006 460 12.1 135 0.8634 0.2158 16,617 22,000 120V 16,391 0.005307 0.005044 A 23,521 0.004623 0.002157 #2 0.045 0.19 15'-2" 0.0007 0.0029 226 2.11 23 4.965 1.241 B 20,022 22,000 120V 19,733 0.004742 0.003807 MDP 26,870 0.0042 0.001517 #2 0.045 0.19 12'-1" 0.0005 0.0023 289 C 23,949 42,000 120V 23,527 0.004738 0.001889 MDP 26,870 0.0042 0.001517 #500kcmil 0.039 0.027 13'-9" 0.0005 0.0004 422 549 G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 VOLTAGE DROP SCHEDULE FEEDER DEVICE UTILITY WIRE SIZE TOTAL VOLTAGE DROP MAX VOLTAGE DROP CALLOUT WIRE SIZE EF-1 VOLTS KVA CIRCUIT WIRE CALLOUT DISCONNECT DESCRIPTION 120V 1P 2W 0.53 D-39 1/2"C,1#12,#12N,#12G 30A/1P/NEMA1 0% - - - 0% MAU-COND1 208V 3P 3W 7.71 A-2,4,6 1/2"C,3#10,#10G 30A/3P/NEMA3R 0.43% (2)#500kcmil - - 0.43% MAU-COND2 208V 3P 3W 4.04 A-8,10,12 1/2"C,3#12,#12G 30A/3P/NEMA3R MDP 0.59% (2)#500kcmil - - 0.59% MAU-CTR 120V 1P 2W 0.58 A-14 1/2"C,1#12,#12N,#12G 30A/1P/NEMA3R A 0.67% #4/0 2.38% (CKT 20) #10 3.06% RTU-1 208V 3P 4W 9.33 MDP-7 1/2"C,3#10,#10N,#10G 30A/3P/NEMA3R DSC 0.77% #2 1.58% (CKT 17) #10 2.34% RTU-2 B 0.74% #2 0.17% (CKT 21) #12 0.9% RTU-3 208V 3P 4W 8.47 MDP-9 1/2"C,3#10,#10N,#10G 30A/3P/NEMA3R C 0.62% #500kcmil 0.14% (CKT 1) #12 0.77% RTU-4 208V 3P 4W 8.47 MDP-10 1/2"C,3#10,#10N,#10G 30A/3P/NEMA3R WH-1 CONTROL 120V 1P 2W 0.53 D-29 1/2"C,1#12,#12N,#12G 30A/1P/NEMA1 WH-2 CONTROL 120V 1P 2W 0.53 D-29 1/2"C,1#12,#12N,#12G 30A/1P/NEMA1 WHRP-1 120V 1P 2W 0.53 D-31 1/2"C,1#12,#12N,#12G 30A/1P/NEMA1 D ONLY THE BRANCH CIRCUIT WITH THE MAXIMUM VOLTAGE DROP IN EACH PANEL IS SHOWN ON THIS SCHEDULE 208V 3P 4W 9.33 MDP-8 1/2"C,3#10,#10N,#10G 30A/3P/NEMA3R ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID SEAL: 02.07.2014 PROJECT NAME & ADDRESS R 1. HVAC & PLUMBING EQUIPMENT SCHEDULE BRANCH CIRCUIT VOLTAGE DROP R 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH D www.peiatl.com PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: 1. 2. 3. 4. 5. 6. 7. 8. ALL FLUORESCENT FIXTURES TO HAVE ELECTRONIC BALLASTS. (T.H.D. <10%) ALL BATTERY BACKED FLUORESCENT BALLASTS TO BE RATED FOR MINIMUM 1100 LUMENS. ALL PRISMATIC LENSES FOR LAY-IN FIXTURES TO BE .125" THICK, PATTERN 12. ALL FLUORESCENT AND PL LAMPS TO BE 4.1K MIN CR1 OF 80, UNLESS NOTED OTHERWISE. ALL FIXTURES AND BALLASTS TO BE LISTED AND CERTIFIED WITH THE CEC DIRECTORY. COORDINATE FIXTURE MOUNTING HEIGHT AND LOCATION REQUIREMENTS W/ARCHITECTURAL DRAWINGS/ DETAILS/ELEVATIONS PRIOR TO ROUGH-IN. SUPPORT FIXTURES TO STRUCTUE, NOT CEILING GRID. ALL FIXTURES LOCATED OVER TABLES ARE TO BE SECURED. SIMPLE GATHERING AND TIE WRAPPING IS NOT SUFFICIENT. PROVIDE WITH REMOTE CAPACITY FOR FIXTURES LOCATED ON EXTERIOR DOORS. SCHEDULES PROJECT #: 14-820.00 E003 3 2 5 4 7 6 8 9 R O F I C I E N P T peiatl.com A-27 #10 7 SIGN 31 J WP 11 11 11 11 4 45" 8 81" 35 2 1 4 PV-4 40.4 24x60 MAU-COND2 1 A-2,4,6 1/2"C,3#10,#10G 24x60 24x60 24x60 D 2A FE 26 J 39 J D-14 J D-7 48" J 96" IG 18" PV-2 D-15 WP GF D 96" 48"/30" 90" 48" 90" 2 C WH-1 CONTROL GF WP D-2 A-3 #10 24x48 24x72 24x72 2 2-3/4"C W/PULLWIRE FROM OUTLET RUN CONDUIT TO 6" ABOVE CEILING. 3 4 5 ALL 120V, 1P, RECEPTACLES IN THE KITCHEN SHALL BE GFI PER NEC 210.8(B). MOUNT AT 30" UNO. 14 POWERVAR LAPC "LOCAL AREA POWER CENTER" BY CPI PANELS. SEE DETAIL 4, DWG.E102. MOUNT 8'-6" AFF. TIE TO CIRCUIT PV-4. 6 PROVIDE INTERCONNECTIONS BETWEEN PIECES OF EQUIPMENT AS REQUIRED. 7 WP J-BOX FOR STOREFRONT SIGN. COORDINATE LOCATION W/SIGN INSTALLER. PROVIDE FINAL CONNECTIONS FROM J-BOX TO SIGN THRU WP TOGGLE SWITCH. 15 16 2' X 2' X 3/4" PLYWOOD, TELEPHONE BACKBOARD WITH FIRE RETARDANT PAINT AND MOUNT BOTTOM OF PLYWOOD AT 5'-0" AFF. MATCH PAINT COLOR TO WALL COLOR. PROVIDE #6 G FROM TELEPHONE BACKBOARD TO SERVICE ENTRANCE GROUND. PROVIDE 3"C W/PULLWIRE FOR TELEPHONE SERVICE. STUB-UP CONDUIT AT 6" AFF W/CAP UNDER BACKBOARD AND EXTEND CONDUIT TO TELEPHONE POINT OF SERVICE AT PROPERTY LINE. COORDINATE LOCATION AND ALL TELEPHONE REQUIREMENTS W/LOCAL TELEPHONE CO. KEYNOTES 23 PROVIDE 2"C W/PULLWIRE TO ROOF FOR SATELLITE DISH. COORDINATE LOCATION W/OWNER. 24 J-BOX FOR CABLE TV. PROVIDE 1"C W/PULLWIRE FROM J-BOX TO 6" ABOVE CEILING. 25 PATCH PANEL. LOCATE 6" FROM CORNER. PROVIDE 2-1"C W/PULLWIRE FROM PATCH PANEL TO 6" ABOVE CEILING. 26 J-BOX ABOVE CEILING FOR RTU CONTROL INTERFACE PANEL. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. FOR SECURITY CAMERAS. COORDINATE LOCATION WITH OWNER FOR IRRIGATION CONTROL PANEL. COORDINATE LOCATION OF PANEL W/IRRIGATION SYSTEM INSTALLER/OWNER. RECEPTACLE MOUNTED AT 48" AFF. 17 PROVIDE 2-PHONE OUTLETS AND DUPLEX RECEPTACLE FOR SECURITY SYSTEM (BY OTHERS). 8 MOUNT IN CEILING FOR TV COORDINATE EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. COORDINATE LOW VOLTAGE REQUIREMENTS WITH LV CONSULTANT. 18 GFI SERVICE RECEPTACLE PROVIDED AND POWERED BY AC UNIT. COORDINATE REQUIREMENTS WITH EQUIPMENT INSTALLED. 9 PROVIDE 2#12, #12G, 3/4"C FROM ICE MAKER TO REMOTE CONDENSER, LOCATED ON ROOF ABOVE ICE MAKER. 19 SEE DETAIL 2, DWG. E102. 20 J-BOX FOR HOOD SUPPRESSION SYSTEM. PROVIDE FINAL CONNECTION FROM J-BOX TO SUPPRESSION SYSTEM. MAKE-UP AIR FAN SHALL SHUT DOWN WHEN SUPPRESSION SYSTEM IS ACTIVATED. 27 28 10 COOLER/FREEZER COMPRESSOR, MOUNTED ON ROOF. 11 PROVIDE CONNECTION TO COOLER MOUNTED, PREWIRED COOLER J-BOX FOR EVAPORATIVE COIL. PROVIDE CONDUIT SEALS AS REQUIRED. 12 PROVIDE CONNECTION TO FREEZER/COOLER PREWIRED LIGHTS & DOOR HEATERS. PROVIDE CONDUIT SEALS AS REQUIRED. 21 PUSH BUTTONS. COORDINATE REQUIREMENTS WITH OWNER. MOUNT J-BOX AT 48" AFF. 22 DOOR CHIME W/TRANSFORMER (PROVIDED BY OWNER-INSTALLED BY ELECTRICAL CONTRACTOR). PROVIDE LOW VOLTAGE WIRING FROM PUSH BUTTONS TO DOOR CHIME. PROVIDE 2-4"X4" 1900 BPX J-BOXES W/1-GANG PLASTER COVER. LOCATE ONE J-BOX @7'-0" AFF & ONE J-BOX @ 4'-0" AFF. PROVIDE 3/4"C W/PULLWIRE BETWEEN J-BOXES AND FROM TOP J-BOX TO 6" ABOVE CEILING FOR AUDIO ONLY. (NO POWER IN THESE CONDUITS) MOUNT J-BOXES 16" WINDOW'S EDGE. PROVIDE 3/4"C W/PULLWIRE FROM BOTTOM J-BOX TO D/T MENU BOARD WEATHERPROOF J-BOX FOR D/T AUDIO. PROVIDE J-BOX UNDER EACH SERVICE WINDOW (CASHIER AND PICK UP). THE PREFABRICATED VEHICLE LOOPS SHALL BE PLACED AND POSITIONED WITH THE BACKEDGE AT 24" PAST CENTERLINE OF EACH SERVICE WINDOW. THE LEAD-IN WIRE SHALL BE FACING IN THE DIRECTION OF EACH SERVICE WINDOW AND J-BOX, APPROXIMATELY 12" FROM THE CURB. THIS SHALL PLACE THE LOOP APPROXIMATELY UNDER THE FRONT AXLE OF THE VEHICLE, WHEN IT IS STOPPED AT EITHER SERVICE WINDOW. THE GROUND LOOP SHALL BE INSTALLED 11/2" TO 2" BELOW THE SURFACE OF THE PAVEMENT. 29 3/4"C W/PULLWIRE FROM CEILING TO ROOF W/WEATHERHEAD OR 90 DEGREE EL AT ROOF. LOCATE NEAR OFFICE FOR "DBS" MUSIC COAX AND FUTURE USE. 30 WP/GFCI RECEPTACLE ON ROOF CURB. 18x48 DUNNAGE CO2 FLOOR PLAN - POWER E100 13 J 40 WHRP-1 1 SEE ARCHITECTURAL ELEVATION DRAWINGS. D-27 B 30 KEYNOTES PROJECT NAME & ADDRESS 56 A 1 13 14 17 SIGN KEYNOTES 18x48 DUNNAGE 16 17 J WP B D-25 WH-2 CONTROL EF-1 34 SEAL: 02.07.2014 R 2 WP GF E D-3 25 29 48" J 21 D-5 4 24 33 96" 4 34 21 J J J 4 FE 37 RTU-4 4 6 1 MDP A D-12 D-1 20.2 18 WP B J2A 18 D-4 A-20 #10 C 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH SIGN 50 14x60 7 ISSUED FOR BID 22 RTU-2 4 ISSUED FOR PERMIT 02-07-14 12 42 8 4 DESCRIPTION: 02-07-14 DSC 17 78" 4 24x48 DUNNAGE 12 2 B-21 8 ISSUE / REVISIONS: DATE 49 20.2 D.9 ISSUED FOR CONSTRUCTION S HB F 6 10 15 S 14x48 4 HB 42 24" 18x48 4 15 A-8,10,12 D-19 4 18 24x60 MAU-CTR 23 58 32 B-42 RTU-3 A-14 24x60 50A 35 45" 24" WP GF 41 40.2 2 2 4 8 32 MAU-COND1 44 6 10 48" 40.3 24" 49A B-32 24" (TYP) D-11 D-9 42" WH 2 40 9.1 38 18x48 DUNNAGE 18x48 81" 81" 81" 81" 81" 2 TYPE K FE 18x48 DUNNAGE 81" 2 1 C-1 IP 8 D-6 45" RTU-1 D-17 30" 36 J 24x36 DUNNAGE 78" 18 11.4 9 19 J 4 40.4 54F R 21X60 51 11.4 40.3 9 23B D-30,32,34 11.4 14 19 6 p 404.330.9798 www.peiatl.com 24x48 DUNNAGE 24X36 35 24x48 DUNNAGE 3 24x48 35 52 F.9 54F 13 DUNNAGE 23A D-24,26,28 TYPE K FE 1 48" 52 11 24X60 24" G 11 12 12 1 31 20.1 26 11 H 78" 9 50B 11 14x60 9 20.4 49B 14x60 20.4 31 48" 20 18X48 GF WP D-2 27 28 10 J 18X48 H J Atlanta, Georgia 30340 18X48 20.1F 30 N I N E E R I Suite 140 D-13 14x60 J G 3600 Dekalb Technology Pkwy 48 IG 4F 4 78" 18X48 60" G E 4 N PV-1 #10 1/4" = 1'-0" KEYNOTES GENERAL NOTES 31 3-RECEPTACLES FOR BATTERY TRANSFORMER(S). 1. SEE SHEET E000 FOR SYMBOLS AND ABBREVIATIONS. 32 EQUIPMENT FED FROM CEILING-MOUNTED RECEPTACLE. REFER TO 1/E102 FOR ADDITIONAL DETAILS. 2. FOR ALL KITCHEN EQUIPMENT, SEE EQUIPMENT SCHEDULE ON SHEET E001 FOR ELECTRICAL CONNECTION INFORMATION, MOUNTING HEIGHTS AND OTHER GENERAL INFORMATION. PROTOTYPE SERIES 33 FOR OFFICE ELEVATIONS AND DIMENSIONS, SEE DWG A114. 3. FOR HVAC & PLUMBING EQUIPMENT, SEE EQUIPMENT SCHEDULE ON SHEET E003 FOR ADDITIONAL ELECTRICAL INFORMATION. 70 SL (C) - SDT 34 EXHAUST FAN ON ROOF TO BE CONTROLLED WITH RTU-2. COORDINATE CONTROL WITH HVAC CONTRACTOR. 35 FOR KITCHEN AND SERVICE ELEVATIONS, SEE DWGS A114 & A116. 36 DEEP 4"x4" JUNCTION BOX FOR ANSUL PULL STATION WITH 3/4"C. STUBBED TO ACCESSIBLE CEILING. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH FIRE SUPPRESSION SYSTEM INSTALLED. 37 (2) DEEP 4"x4" JUNCTION BOXES FOR SMOKE DETECTOR ANNUNCIATORS WITH 3/4"C. STUBBED TO ACCESSIBLE CEILING. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH MECHANICAL CONTRACTOR. 38 RECEPTACLE FOR MOBILE FRYER FILTER. 39 J-BOX FOR CAMERA. STUB 3/4"C. TO ACCESSIBLE CEILING. 40 ROUTE (1) 1"C. TO PANEL MDP FOR FUTURE EQUIPMENT. J-BOX TO BE MOUNTED AT 30" AFF. 41 ROUTE CONDUIT IN SLAB TO CENTERLINE TABLE MAIN CONNECTION. COORDINATE EXACT ROUGH IN LOCATION WITH EQUIPMENT CUTSHEET AND MANUFACTURER'S WIRING INSTRUCTION. SEE KITCHEN EQUIPMENT SCHEDULE ON SHEET E001 FOR FEEDER INFORMATION. SHEET TITLE: FLOOR PLAN POWER PROJECT #: 14-820.00 E100 3 2 5 4 7 6 8 9 R O F I C I E N P T (TYP. OF ALL C1) 8 peiatl.com C1 C1 C1 G E N G N I N E E R I 3600 Dekalb Technology Pkwy 11 Suite 140 Atlanta, Georgia 30340 J p 404.330.9798 EM G G H EM2 G G H A-29 6 12 X G www.peiatl.com AV1 AC TYPE K FE 'Sc' 5 5 J J J R J 5 D f G G 5 C-5 X K D f TYPE K FE 4 2 1 F.9 F 6 G 2 A-23 #10 D g 4 F EM AV1 C3 AV2 D1 D1 g B1 D1 g g H AV2 H D f 2 ISSUED FOR CONSTRUCTION 2 ISSUE / REVISIONS: AC EM F P 7 A-13 DATE 'Sa' 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID P C3 4 D AV1 g g AV1 2 2 4 D D g D g 2 1 2 A-1 #10 G DE f C3 D1 AC 4 4 2A FE 'Se' F DE D g D.9 AV1 AC AC 4 g C1 A-7 'Sb' F D D D g C1 g K A C1 F C1 AC A-9 #10 2 F X 9'-0" AFF C1 F PROJECT NAME & ADDRESS EM G C1 C1 K C G X AC D1 g C1 D 9'-0" AFF D g L g EM C1 EM2 B SEAL: 02.07.2014 R 2 E os AV2 10 A-21 #10 os AV1 4 EM2 f g 2A FE AV2 4 X EM 'Sd' F g g X A-11 #10 6 DE WP 4 AV1 g D1 4 EM D A-19 #10 3 AC EM 4 g 13 A-17 #10 4 D1 g G C1 G G B 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH F F DESCRIPTION: G A G G 1 E101 FLOOR PLAN - LIGHTING 1/4" = 1'-0" GENERAL NOTES KEYNOTES TO EMERGENCY LIGHTS TO NON-EMERG. LIGHTS CONTACTOR 1. PROVIDE UNSWITCHED HOT TO ALL EMERGENCY AND EXIT LIGHTING. SEE DETAIL 2/E101 FOR ADDITIONAL DETAILS. 1 ALL FLUORESCENT FIXTURES IN KITCHEN/SERVING AREAS SHALL BE PROVIDED WITH GASKETED LENS OR SHATTERPROOF LAMPS. 2. LIGHTING CONTROLS SHALL BE DONE VIA LIGHTING CONTACTOR WITH PROGRAMMABLE TIMECLOCK AND EXTERIOR MOUNTED PHOTOCELL. 2 LIGHT FIXTURE AND SWITCH, SUPPLIED W/COOLER/FREEZER, ARE PREWIRED TO COOLER/FREEZER J-BOX. SEE DWG. E100 FOR POWER CONNECTION TO J-BOX. 3 SWITCHBANK, SEE DETAIL 3, DWG. E102. 4 MOUNT TRACK W/REMOTE TRANSFORMER ABOVE CEILING. CONNECT 120V CIRCUIT TO PRIMARY OF TRANSFORMER AND MAKE FINAL CONNECTIONS FROM SECONDARY OF TRANSFORMER TO TRACK. NIPPLE PROTOTYPE SERIES TAP WIREWAY NIPPLE 5 BREAKER IN PANEL PANEL NOTE: DETAIL APPLIES TO EMERGENCY LIGHTING CONNECTED TO CIRCUITS CONTROLLED BY A LIGHTING CONTACTOR. 2 E101 WIRING DETAIL NOT TO SCALE HOOD LIGHT FIXTURES AND SWITCH, SUPPLIED W/HOOD, ARE PREWIRED TO HOOD J-BOX. PROVIDE CONNECTION TO J-BOX, BETWEEN J-BOXES AND CIRCUIT, AS INDICATED. SEE ARCHITECTURAL DEAIL. 6 TO RECEPTACLE FOR FRYER TIMER. SEE DWG. E100. 7 ROUTE CIRCUIT (CONDUIT & CONDUCTORS) INSIDE SHORT WALL. 8 MOUNT IN SOFFIT. 9 J-BOX FOR BUG LIGHT. COORDINATE LOCATION W/BUG LIGHT INSTALLER/ OWNER. 10 SWITCH TO TURN ON FIXTURE IN CAN-WASH AREA ONLY. 11 3/4" CW/2#12, 1#12G TO J-BOX AT ZAXBY'S DRIVE THRU MENU SIGN. 12 OVERRIDE SWITCH TO SHUTOFF POWER TO DRIVE THRU MENU SIGN. 13 LIGHTING CONTACTOR PANEL. 70 SL (C) - SDT SHEET TITLE: FLOOR PLAN LIGHTING PROJECT #: 14-820.00 E101 R O F I C I E N P T HOOD FANS SUPPLIED BY KITCHEN EQUIP. SUPPLIER RECESSED JUNCTION BOX. SUPPORT FROM STRUCTURE CONDUIT CEILING TILE peiatl.com TO HOOD PANEL TO HOOD PANEL CABLE STRAIN RELIEF KEF-2 (ON ROOF) G N I N E E R I 3600 Dekalb Technology Pkwy KEF-1 (ON ROOF) S S S S S S Sf a b c d f g e Suite 140 Atlanta, Georgia 30340 HEAVY-DUTY SO CORD INSUL-GRIP PLUG BY HUBBELL OR EQUAL. G E N p 404.330.9798 www.peiatl.com HOOD #1 R 1 E102 KITCHEN DROP DETAIL NOTE: SWITCHES SHALL BE INSTALLED BETWEEN STUDS. MAKE (2) ROWS IF NECESSARY. DO NOT CUT STUDS TO ACCOMMODATE A SINGLE ROW OF SWITCHES. DISCONNECT PROVIDED W/FAN (TYPICAL) N.T.S. 1. HOODS ARE PROVIDED WITH PANEL (LOCATED ON HOOD #2) TO CONNECT CIRCUITS FOR EXHAUST FANS,LIGHTS & TIMER. ELECTRICAL CONTRACTOR SHALL MAKE CONNECTIONS TO HOOD J-BOX & FANS. (SWITCHES FOR FANS & LIGHTS ARE PROVIDED WITH HOOD). 3 E102 2 DRIVE-THRU (ABOVE WINDOW) E102 MAC VICTOR POWER STRIP (MVPS-515-12) FURNISHED BY CPI PANELS DRIVE-THRU SWITCH BANK DETAIL N.T.S. HOOD WIRING DETAIL N.T.S. ISSUED FOR CONSTRUCTION IG RECEPTACLES FOR POS (PV-4) INPUT POWER CONDUIT FROM CIRCUIT BREAKER, A-14. PROVIDE ISOLATED GROUND CONDUCTOR. 78" 78" 78" GFI RECEPTACLES PREP AREA (PV-3) ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID POWERVAR UPM POWER CONDITIONER & BATTERY OFFICE COMPUTER MAXIMUM DEPTH = 10.5" INDICATOR LIGHTS POWERVAR LAPC CIRCUIT (PV-4) NOTES: INPUT WIRING FROM CIRCUIT BREAKER MUST BE IN A SEPARATE CONDUIT OR MC CABLE FROM ALL OUTPUT WIRING. 2. CONDUIT ENTRY IS NOT ALLOWED ON THE RIGHT HAND SIDE, WHICH IS DEDICATED FOR THE UPM POWER RECEPTACLE. 3. NUMBER OF PRE-PUNCHED 1/2" EMT KNOCKOUTS PROVIDED: TOP BOTTOM LEFT SIDE INPUT POWER CONDUIT 1 1 OUTPUT POW CONDUITS 2 2 3 UPM POWER OFF CONDUIT 1 - 4. B NORMAL/BYPASS ROTARY SWITCH SERVING LINE IG RECEPTACLES SERVING, COUNTER (PV-1) ALL CONDUITS ENTERING OR EXITING THE TOP OF THE ENCLOSURE ARE ROUTED BEHIND THE POWERVAR UPM WHICH IS OFFSET FROM THE WALL BY 1.5" BY THE SHELF. 4 E102 POWERVAR LAPC DETAIL N.T.S. CONTACT: CPI PANELS Bryan Stryker ([email protected]) PHONE: 704-364-9029 FAX: 704-367-1215 PROJECT NAME & ADDRESS R 5. SEAL: 02.07.2014 STARTER/ CONTROLLER EXHAUST FAN(S) LEGEND TO POWER SOURCE TO POWER SOURCE POWER 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH 1. N CONTROL STARTER/ CONTROLLER S SUPPLY FAN VALVE SHUNT TRIP OR SOLENOID UNDER HOOD SPRAY NOZZLE HOOD LIGHT SERVICE DISCONNECT SWITCH BUILDING STEEL INTERSYSTEM BONDING TERMINATION #4 CU #2/0 CU #2/0 CU #2/0 CU #4 CU EXHAUST HOOD #6 CU S S TO CATV REMOTE PULL STATION S TO TELEPHONE TERMINAL BOARD F FIRE SUPPRESSION PANEL POWER PANEL TO BUILDING FIRE ALARM SYSTEM TO GAS SUPPLY TO POWER SOURCE NOTES 2&3 3/4" x 10' GROUND ROD (MIN. 6' APART) GROUNDING CLAMP JUMPER REBAR ENCASED IN BUILDING FOOTING MIN 1/2" x 20' SERVICE ENTRANCE CONDUIT METAL WATER SERVICE PROTOTYPE SERIES S 70 SL (C) - SDT ELECTRIC EQUIPMENT SHEET TITLE: NOTES: GAS EQUIPMENT 1. PROVIDE LOCAL DISCONNECT WHEN NOT INTEGRAL WITH FAN(S). 2. GROUP WALL MOUNTED START-STOP STATIONS WITH RED RUN LIGHT AND LABEL EQUIPMENT CONTROLLED (WHEN NOT HOOD MOUNTED). 3. REFER TO KITCHEN DOCUMENTS FOR SPECIFIC REQUIREMENTS AND SWITCH LOCATIONS - WALL OR HOOD MOUNTED. 4. REFERENCE MECHANICAL AND KITCHEN DOCUMENTS FOR LOGIC, METHOD AND SEQUENCE OF CONTROL (BMS, HARDWIRED, ETC.). 5. CONTRACTOR SHALL INSTALL BOTH POWER AND CONTROLS TO MAKE SYSTEMS FULLY OPERATIONAL. 6. PROVIDE SHUNT TRIP DEVICES FOR EACH ELECTRICAL CIRCUIT SERVING HEAT PRODUCING EQUIPMENT UNDER EXHAUST HOOD. 7. ALL GAS AND ELECTRIC HEAT PRODUCING EQUIPMENT, THAT IS PROTECTED BY A FIRE-EXTINGUISHING SYSTEM FOR A COOKING OPERATION, MUST AUTOMATICALLY SHUT OFF UPON ACTIVATION OF THE FIRE EXTINGUISHING SYSTEM. 5 E102 HOOD FIRE SUPPRESSION SYSTEM N.T.S. DETAILS 6 E102 GROUNDING AND BONDING DETAIL N.T.S. PROJECT #: 14-820.00 E102 R O F I C I E N P T peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com UTILITY A-39 1"C,1#8,#8N,#10G A-31,33 #10 T 1 R WP J SB 3 SC E.J. 1 PYLON SIGN A-41 2 J E.J. WP DRIVE THRU MENU KEYNOTES 1. EC SHALL PROVIDE AND INSTALL CONCRETE POLE BASES AS INDICATED PER DETAIL #3 ON THIS DRAWING. EC SHALL FIELD COORDINATE THE EXACT POLE BASE SIZE WITH THE ACTUAL FIXTURES AND POLES PURCHASED UTILIZING THE APPROVED MANUFACTURER TEMPLATE. 2. THE MINIMUM SIZE CONDUIT FOR THE SITE LIGHTING SHALL BE 1" SCHEDULE 40 PVC CONDUIT WITH RGS TYPE ELBOWS AND STUB-UPS. ALL CONDUIT SHALL BE INSTALLED A MINIMUM OF 24" BELOW GRADE. THE MINIMUM WIRE SIZE FOR THE SITE LIGHTING BRANCH CIRCUITS SHALL BE #10 (HOT, NEUTRAL, AND GROUND). 1 IN 1" PVC C. 2 TO J-BOX AT DRIVE-THRU WINDOW, SEE DRAWING E101. 3 PROVIDE 30/1/3R/NF DISCONNECT FOR SIGNAGE. 4 PROVIDE LIGHT DUTY PEDESTRIAN GRADE PULL BOX, CHRISTY OR CARSON OR APPROVED EQUAL. MAY BE CIRCULAR OR RECTAGULAR IN SHAPE. SHALL BE MINIMUM 12" DEEP. ROUTE (2) 1"C SPARES STUBBED AT 6" ABOVE FINISHED FLOOR BELOW PANEL A TO THE PULL BOX. PROVIDE WATERPROOF LAMINATED TAGS AT BOTH ENDS. 3. ALL EXTERIOR SITE, PARKING, AND BUILDING PERIMETER LIGHT FIXTURES SHALL BE CONTROLLED PER THE STANDARD ZAXBY'S LIGHTING MANAGER AS SHOWN ON DRAWING E-001. PROVIDE WEATHERPROOF/GFCI SWITCHED DUPLEX RECEPTACLE AT DUMPSTER. SEE ARCHITECTURAL SHEET A118 FOR EXACT LOCATION. COORDINATE WITH TENANT FOR LOCATION OF THE SWITCH. 4. THE EC SHALL NOT DEVIATE FROM THE WIRING INDICATED. VOLTAGE DROP CALCULATIONS HAVE BEEN PERFORMED AND FACTORED IN FOR THIS LAYOUT, LOADS, AND WIRING SPECIFIED. 5. REFER TO DRAWING E-003 FOR LIGHTING FIXTURE SCHEDULE. 6. THE EC SHALL COORDINATE NEW ELECTRICAL INSTALLATION WITH ALL NEW AND EXISTING UTILITIES. EC SHALL CONFIRM LOCATION OF ALL EXISTING UTILITIES BEFORE DIGGING/TRENCHING. C.J. C.J. E.J. GENERAL NOTES E.J. 3 SC E.J. E.J. C.J. C.J. E.J. E.J. E.J. C.J. C.J. C.J. C.J. C.J. C.J. E.J. A-22,24 #10 E.J. E.J. C.J. C.J. C.J. E.J. SC SC Maple Loop Drive 5 A-35,37 #10 A-16,18 #10 SA SC 4 SA Label SA SB SC Description AP2-250PS-QT-3H AP2-250PS-QT-2H-HSS AP2-250PS-QT-FT Watts 292 292 292 ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID SEAL: 02.07.2014 J R PROJECT NAME & ADDRESS 25'-0" SA SA SA 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH 4 SC J Luminaire Schedule Qty Symbol 5 1 7 ISSUED FOR CONSTRUCTION SC 2'-5" SEE STRUCTURAL DRAWING FOR TYPICAL POLE BASE DETAIL A-15 #10 1 2 E103 SITE LIGHTING POLE DETAIL NOT TO SCALE PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: 1 E103 SITE LIGHTING PLAN SITE POWER ELECTRICAL 1" = 20'-0" PROJECT #: 14-820.00 E103 R PLUMBING SPECIFICATIONS N P PLUMBING SPECIFICATIONS F I C I E T PLUMBING ABBREVIATIONS O (CONTINUED) peiatl.com A/F ABOVE FLOOR HD HUB DRAIN AFF ABOVE FINISHED FLOOR HW HOT WATER AFG ABOVE FINISHED GRADE HWR HOT WATER RETURN AP ACCESS PANEL IMB ICE MACHINE BOX B/F BELOW FLOOR IE INVERT ELEVATION BFP BACKFLOW PREVENTER IW INDIRECT WASTE L / LAV LAVATORY BOP BOTTOM OF PIPE MBH 1000 BTU/HR C L CENTER LINE MS MOP SINK CD CONDENSATE DRAIN MV MIXING VALVE CO CLEANOUT O/H OVERHEAD CONN CONNECTION G NATURAL GAS CONT CONTINUATION PRV PRESSURE REDUCING VALVE CFH CUBIC FEET PER HOUR S / SAN SANITARY CW COLD WATER SK SINK DOWN TP TRAP PRIMER EL ELEVATION T&P TEMPERATURE & PRESSURE ELECTRIC WATER COOLER TYP TYPICAL FCO FLOOR CLEANOUT UR URINAL FD FLOOR DRAIN V VENT FF FINISHED FLOOR VTR VENT THROUGH ROOF FFE FINISHED FLOOR ELEVATION WC WATER CLOSET FS FLOOR SINK W.C. WATER COLUMN FWH FREEZEPROOF WALL HYDRANT WCO WALL CLEANOUT SYMBOL DESCRIPTION COLD WATER PIPE MIXING VALVE HOT WATER PIPE BACKFLOW PREVENTER ASSEMBLY HOT WATER RETURN PIPE T&P RELIEF VALVE G NATURAL GAS PIPE SOLENOID VALVE S SANITARY PIPE (BELOW FLOOR) HOSE BIBB S SANITARY PIPE (ABOVE FLOOR) WALL HYDRANT GW GREASE WASTE PIPE (BELOW FLOOR) WATER HAMMER ARRESTOR GW GREASE WASTE PIPE (ABOVE FLOOR) GAS COCK VENT PIPE THERMOMETER CONDENSATE DRAINAGE PIPE VACUUM RELIEF VALVE CD PIPE UP P UNION PIPE TEE FROM TOP STRAINER SLEEVES ARE NOT REQUIRED AT INDIVIDUAL PLUMBING FIXTURES OR IN CONCRETE FLOOR SLABS ON GRADE. WALL SLEEVES SHALL BE FULL THICKNESS OF WALLS. SLEEVES MAY BE OMITTED WHEN OPENINGS ARE CORE DRILLED FOR CONCEALED VERTICAL AND HORIZONTAL PIPING. MAKE SLEEVES THROUGH OUTSIDE WALLS WATERTIGHT. CAULK BETWEEN PLUMBING PIPE AND SLEEVE. PACK WITH FIBERGLASS AND CAULK, 1" DEEP AT EACH FACE WITH NON-HARDENING SEALANT BETWEEN PIPE AND SLEEVE. SIZE SLEEVES FOR INSULATED PIPES TO ALLOW FULL THICKNESS INSULATION. PIPES PENETRATING WALLS BELOW GRADE SHALL BE SEALED WITH A WATERPROOF, MODULAR, MECHANICAL EXPANSION SEAL CONSISTING OF INTERLOCKING SYNTHETIC RUBBER LINKS SHAPED TO CONTINUOUSLY FILL THE ANNULAR SPACE BETWEEN THE PIPE AND WALL OPENING. SIZING OF LINKS AND WALL SLEEVE SHALL BE DETERMINED BY THE MANUFACTURER. SANITARY PIPING AND VENT PIPING ABOVE GROUND SHALL BE PVC SCHEDULE 40 TYPE DWV WITH SOLVENT WELD JOINTS. SOLVENT WELD JOINTS SHALL MEET ASTM D-2665. DATE THE CONTRACTOR SHALL OBTAIN EXACT WALL, FIXTURE, AND LAYOUT DIMENSIONS FROM THE ARCHITECTURAL DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ROUGH-IN AND INSTALLATION DRAWINGS FOR ALL PLUMBING FIXTURES, KITCHEN EQUIPMENT AND OWNER FURNISHED EQUIPMENT (AS APPLICABLE), AND SHALL COORDINATE THE PLUMBING INSTALLATION PRIOR TO COMMENCING THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL NECESSARY VALVES, CONNECTIONS, TRAPS, ACCESS PANELS, UNIONS, ESCUTCHEONS, WATER HAMMER ARRESTORS, VACUUM BREAKERS, RELIEF VALVES, PIPE INSULATION, AND EQUIPMENT SPECIALTY DEVICES AS REQUIRED TO FACILITATE COMPLETE AND OPERATIONAL CONDITIONS WHICH ARE IN STRICT COMPLIANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. SUBMITTALS FURNISH SHOP DRAWINGS FOR MANUFACTURED PRODUCTS. ALL ITEMS MUST BE MARKED TO INDICATE WHICH FIXTURE, EQUIPMENT, OR DEVICE THE SUBMITTAL SHEET IS MEANT TO REPRESENT. THESE MARKS MUST MATCH THOSE ON THE DRAWINGS. ALL ITEMS MUST COME TOGETHER IN ONE PACKAGE AT THE SAME TIME, SEPARATE SUBMITTALS FOR FIXTURES AND EQUIPMENT ARE NOT ACCEPTABLE. SUBMITTALS SHALL BE SUBMITTED IN ELECTRONIC PDF FORMAT. WASTE AND VENT PIPING SHALL BE TESTED IN ACCORDANCE WITH THE GOVERNING CODES. AT A MINIMUM, WASTE PIPING SHALL BE TESTED WITH AT LEAST 10 FOOT OF WATER HEAD PRESSURE APPLIED. TESTING WITH AIR IS NOT ALLOWED. SERVICE PIPING BELOW GRADE (UP TO 3" IN SIZE): TYPE 'K' COPPER TUBING, ASTM B88-1988A WITH 95-5 SOLDERED JOINTS AND WROUGHT COPPER, ANSI B16.22-1988A, OR CAST BRONZE, ANSI 95-5 B16.18-1988A, SOCKET FITTINGS. EXTEND TO A POINT 1'-" ABOVE FINISHED FLOOR. BURIED DOMESTIC WATER PIPING SHALL BE WRAPPED WITH "TAPE COAT 20," "REPUBLIC X-TRU-COAT" OR APPROVED PVC JACKETING. DOMESTIC WATER PIPING SHALL BE PURGED OF DELETERIOUS MATTER AND DISINFECTED PRIOR TO UTILIZATION. PIPING TO BE FLUSHED AND STERILIZED IN ACCORDANCE WITH IPC 610.1 AND ALL APPLICABLE LOCAL AND STATE HEALTH DEPARTMENT STANDARDS. FOR CPVC COLD WATER PIPING, INSULATE ALL HORIZONTAL PIPING 112" AND OVER LOCATED ABOVE CEILING. THE INSULATION SHALL BE 1" THICK. WHERE SEVERAL PIPES 212" AND SMALLER RUN PARALLEL AND IN THE SAME PLANE, THEY MAY BE SUPPORTED ON GANG OR MULTIPLE HANGERS. LARGER PIPING SHALL BE INDEPENDENTLY HUNG, RUN PARALLEL AND BE EQUALLY SPACED. NATURAL GAS SYSTEMS AND ACCESSORIES ALL GAS PIPING SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE INTERNATIONAL FUEL GAS CODE AND NFPA 54. THE PRIMARY SPECIFICATION FOR NATURAL GAS PIPING SHALL BE AS FOLLOWS: SUPPORT EACH HORIZONTAL LENGTH OF SANITARY, WASTE AND VENT PIPE. MAXIMUM DISTANCE BETWEEN HANGERS SHALL BE 5'. TRAP PRIMER GATE VALVE FLOOR CLEANOUT / GRADE CLEANOUT VERTICAL PIPE SUBJECT TO MOVEMENT SHALL BE SUPPORTED FROM THE WALL BY MEANS OF A PIPE CLAMP. SUPPORT DOMESTIC WATER PIPING IN SPACES BEHIND PLUMBING FIXTURES BY BRACKETS AND U-BOLTS SECURED TO WASTE AND VENT STACKS. SIZE U-BOLTS TO BEAR ON THE PIPING. CHECK VALVE VENT THROUGH ROOF HANGERS SHALL BE COMPLETE WITH RODS AND SUPPORTS PROPORTIONED TO THE SIZE OF PIPE TO BE SUPPORTED, IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. PRESSURE REDUCING VALVE PIPE CLEANOUT / WALL CLEANOUT DO NOT PIERCE WATERPROOFING WITH SUPPORT BOLTS. SIZE HANGERS FOR INSULATED PIPING TO BEAR ON OUTSIDE OF INSULATION. PROVIDE INSULATION PROTECTORS AT HANGERS BEARING ON THE OUTSIDE OF INSULATION. PROVIDE A RIGID INSERT OR RIGID INSULATION AT EACH INSULATION PROTECTOR. SEISMIC NOTES PLUMBING SYSTEM SHALL BE INSTALLED IN STRICT ACCORDANCE WITH ASCE 7-05 CHAPTER 13 AND ALL LOCAL SEISMIC REQUIREMENTS. COMPONENTS SHALL BE ASSIGNED AN IMPORTANCE FACTOR (IP) OF 1.0, WITH THE EXCEPTION OF NATURAL GAS AND SPRINKLER PIPING, BOTH OF WHICH SHALL HAVE THE IP VALUE OF 1.5. COMPONENTS OF THE PLUMBING SYSTEM AND THEIR SUPPORTS SHALL MEET THE REQUIREMENTS OF SECTION 13.6. ATTACHMENTS BETWEEN COMPONENTS AND SUPPORTS SHALL MEET THE REQUIREMENTS OF SECTION 13.4. STEEL PIPE: ASTM A 53/A 53M, BLACK STEEL, SCHEDULE 40, TYPE E OR S, GRADE B. MALLEABLE-IRON THREADED FITTINGS: ASME B16.3, CLASS 150, STANDARD PATTERN. WROUGHT-STEEL WELDING FITTINGS: ASTM A 234/A 234M FOR BUTT WELDING AND SOCKET WELDING. UNIONS: ASME B16.39, CLASS 150, MALLEABLE IRON WITH BRASS-TO-IRON SEAT, GROUND JOINT, AND THREADED ENDS. PROTOTYPE SERIES JOINING MATERIALS: JOINT COMPOUND AND TAPE: SUITABLE FOR NATURAL GAS. 70 SL (C) - SDT WELDING FILLER METALS: COMPLY WITH AWS D10.12/D10.12M FOR WELDING MATERIALS APPROPRIATE FOR WALL THICKNESS AND CHEMICAL ANALYSIS OF STEEL PIPE BEING WELDED. BRAZING FILLER METALS: ALLOY WITH MELTING POINT GREATER THAN 1000 DEG. F. COMPLYING WITH AWS A5.8/A5.8M. BRAZING ALLOYS CONTAINING MORE THAN O.O5 PERCENT PHOSPHORUS ARE PROHIBITED. SHEET TITLE: GENERAL INFO & SPECIFICATIONS PLUMBING BALL VALVES: THREE PIECE BODY, FULL PORT, CHROME PLATED BALL, BLOWOUT PROOF STEM, TFE SEATS, UL LISTED FOR FLAMMABLE LIQUIDS, 600 PSI WOG, THREADED ENDS. AFTER HANGER RODS ARE INSTALLED IN FINISHED CONCRETE CEILING, FILL THE REMAINING OPENING WITH CEMENT SO THAT NO HOLE SHOWS AT THE CEILING. PRESSURE REGULATOR VALVE: SINGLE STAGE AND SUITABLE FOR NATURAL GAS, STEEL JACKET AND CORROSION RESISTANT COMPONENTS, THREADED FRO REGULATORS NPS 2 AND SMALLER. WHERE COPPER PIPING IS USED, NONFERROUS METAL SUPPORT(S) OR PROPER ISOLATION BETWEEN DISSIMILAR MATERIALS SHALL BE PROVIDED. INSTALL MANUAL GAS SHUTOFF VALVE FOR EACH GAS APPLIANCE AHEAD OF CORRUGATED STAINLESS STEEL TUBING OR COPPER CONNECTOR. PIPE HANGERS AND SUPPORTS SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH RECOMMENDATIONS SET FORTH IN MANUFACTURER'S STANDARDIZATION SOCIETY STANDARD PRACTICES NO. SP-69 AND SP-58. INSTALL UNIONS IN PIPES NPS 2 AND SMALLER, ADJACENT TO EACH VALVE, AT FINAL CONNECTION TO EACH PIECE OF EQUIPMENT. HANGERS AND SUPPORTS SHALL BE MANUFACTURED BY F&S, GRINNELL, MICHIGAN OR APPROVED EQUAL. PROJECT NAME & ADDRESS CERTIFICATIONS SHALL BE PROVIDED INDICATING THAT ALL BACKFLOW PREVENTERS HAVE BEEN TESTED AND APPROVED. FOR COPPER COLD WATER PIPING, INSULATE ALL HORIZONTAL PIPING LOCATED ABOVE CEILING AND ALL VERTICAL PIPING LOCATED IN AN EXTERIOR WALL. PIPE UP TO 1": 12" THICK. PIPING 114" AND OVER: 1" THICK INSULATION P-TRAP SEAL: 02.07.2014 DOMESTIC WATER PIPING SHALL BE TESTED IN ACCORDANCE WITH ALL GOVERNING CODES. HANGERS AND SUPPORTS UNDERGROUND PLUMBING PIPING SHALL BE FIRMLY BEDDED ON SOLID GROUND ON THE BODY OF THE PIPE. PIPE CONTINUATION ISSUED FOR BID WATER PIPING ABOVE FLOOR: HOT AND COLD WATER PIPING ABOVE GROUND SHALL BE CPVC (CHLORINATED POLYVINYL CHLORIDE) SCHEDULE 40 WITH SOLVENT WELD JOINTS WHEN APPROVED BY THE AUTHORITY HAVING JURISDICTION. PIPING SHALL MEET ASTM D 2848 AND SHALL BE CERTIFIED BY THE NSF INTERNATIONAL FOR USE WITH POTABLE WATER SYSTEMS. SOLVENT CEMENTS FOR CPVC PLASTIC PIPING SHALL MEET ASTM F437, ASTM F438 AND ASTM F439. WHERE RECIRCULATED HOT WATER IS SHOWN, INSULATE ALL HOT WATER AND RECIRCULATION PIPING WITH 1" THICK INSULATION PER CHAPTER 5 OF IECC. FOR NON-RECIRCULATED HOT WATER SYSTEMS, INSULATION THICKNESS SHALL BE AS FOLLOWS: PIPE UP TO 1": 12" THICK INSULATION. PIPE 114" TO 2": 1" THICK INSULATION FLOOR SINK ISSUED FOR PERMIT 02-07-14 SERVICE PIPING BELOW GRADE: CPVC (CHLORINATED POLYVINYL CHLORIDE) SCHEDULE 40 WHEN APPROVED BY THE AUTHORITY HAVING JURISDICTION. SHALL MEET ASTM D2846 AND ASTM F 441. ELECTRICAL DATA FOR POWERED EQUIPMENT MUST BE INDICATED ON THE SUBMITTAL SHEET FOR THAT ITEM. PIPE CAP DESCRIPTION: 02-07-14 DOMESTIC WATER SYSTEMS AND ACCESSORIES THE PRIMARY SPECIFICATION FOR DOMESTIC WATER PIPING SHALL BE AS FOLLOWS: INSULATION INSULATE ALL DOMESTIC HOT WATER PIPING REGARDLESS OF MATERIAL. THE INSULATION SHALL SUBMITTAL REVIEW IS CONSIDERED AS GENERAL ACCEPTANCE OF THE BASIC APPLICABILITY OF THE EQUIPMENT. CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION AND/OR ALTERNATE ARRANGEMENT OF THE EQUIPMENT WITHIN A GIVEN SPACE. WHEN THE CONTRACTOR DESIRES TO USE SUBSTITUTED EQUIPMENT, HE SHALL BE RESPONSIBLE FOR ANY COORDINATION OR ADDITIONAL COST BROUGHT ON BY THE USE OF THIS EQUIPMENT. ISSUE / REVISIONS: ALL VENTS THROUGH ROOF SHALL BE LOCATED AT LEAST 10'-0" AWAY FROM ANY AIR INTAKE, EVAPORATIVE COOLER, OR ANY OTHER DEVICE THAT WOULD DRAW AIR FROM THE VENT. FLASH AROUND ALL PIPES PENETRATING THROUGH ROOF WITH STANDARD MANUFACTURED FLASHINGS. FLASHING SHALL BE SHEET METAL WITH RUBBER GASKETS AND SHALL EXTEND INTO ROOFING AND UP PIPE DISTANCES IN ACCORDANCE WITH THE LOCAL CODE. ALL OPTIONS AND/OR FINISHES MUST BE CLEARLY MARKED ON THE SUBMITTAL SHEET. A MODEL NUMBER LISTING ON A COVER SHEET IS NOT AN ACCEPTABLE SUBSTITUTE FOR MARKING THE ACTUAL SUBMITTAL SHEET. FLOOR DRAIN BALL VALVE R THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE ARCHITECTURAL DRAWINGS TO ENSURE THERE IS ADEQUATE WALL THICKNESS SUCH THAT ALL WATER PIPING, SANITARY PIPING, VENT PIPING, WALL CLEANOUTS, HOSE BIBBS, NON FREEZE WALL HYDRANTS, AND RECESSED ACCESS PANELS WILL FIT IN WALL SPACE. CONTRACTOR SHALL NOTIFY THE ARCHITECT IF WALL SPACE IS INADEQUATE PRIOR TO COMMENCING WORK. PIPE TEE FROM BOTTOM HUB DRAIN p 404.330.9798 www.peiatl.com ISSUED FOR CONSTRUCTION THE SPACING OF SUPPORTS SHALL BE AS FOLLOWS: METAL (STEEL AND COPPER PIPES): 1" AND SMALLER, SUPPORT SPACING SHALL NOT EXCEED 8' APART. 114" AND LARGER, SUPPORT SPACING SHALL NOT EXCEED 8' APART. PLASTIC PIPES: 1" AND SMALLER, SUPPORT SPACING SHALL NOT EXCEED 3' APART. 114" TO 2", SUPPORT SPACING SHALL NOT EXCEED 4' APART. 2" AND LARGER, SPACING SHALL NOT EXCEED 6' APART. IN ALL CASES, PIPES SHALL BE SUPPORTED WITHIN 1' OF EACH ELBOW. DIRECTIONAL FLOW ARROW Suite 140 Atlanta, Georgia 30340 PRESSURE GAUGE WITH GAUGE COCK PIPE DOWN 3600 Dekalb Technology Pkwy WASTE AND VENT PIPING SYSTEMS AND ACCESSORIES SANITARY PIPING BELOW GROUND SHALL BE PVC SCHEDULE 40 TYPE DWV WITH SOLVENT WELD JOINTS. SOLVENT WELD JOINTS SHALL MEET ASTM T-702.3 AND ASTM D-2665. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH THE REQUIREMENTS OF THE COUNTY HEALTH DEPARTMENT AND OTHER LOCAL AUTHORITIES HAVING JURISDICTION REGARDING CROSS CONNECTION CONTROL OR OBTAINING A FOOD SERVICE PERMIT (AS APPLICABLE). REPORT ANY OBSERVED DISCREPANCIES TO THE A/E PRIOR TO COMMENCING WITH THE WORK. DESCRIPTION N I N E E R I ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE BEST RECOGNIZED PRACTICE IN THE FIELD CONCERNED. MANUFACTURED ITEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED DIRECTIONS, SPECIFICATIONS AND RECOMMENDATIONS. PIPE PENETRATIONS THROUGH FIRE RATED WALLS OR FLOORS SHALL HAVE EQUIVALENTLY RATED SLEEVES AND SHALL BE SEALED AND FIRE CAULKED WITH A U.L. LISTED FIRE STOPPING SYSTEM INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S LISTED DETAILS AND SPECIFICATIONS. PLUMBING LEGEND G SLEEVES FOR ALL PIPING PENETRATING FIRE RATED WALLS AND FLOORS SHALL BE PROVIDED WITH 3M PIPE BARRIER NO. CP-25 FIRE PROOFING CAULKING, OR EQUAL, IN ANNULAR SPACE BETWEEN SLEEVE AND PIPING. DOMESTIC WATER PIPING SHALL BE PURGED OF DELETERIOUS MATTER AND DISINFECTED PRIOR TO UTILIZATION. PIPING TO BE FLUSHED AND STERILIZED IN ACCORDANCE WITH IPC 610.1 AND ALL APPLICABLE LOCAL AND STATE HEALTH DEPARTMENT STANDARDS. WATER HAMMER ARRESTER N SLEEVES SHALL BE STANDARD WEIGHT STEEL IN CONCRETE AND MASONRY CONSTRUCTION. COORDINATE THE ELECTRICAL REQUIREMENTS AND CHARACTERISTICS OF ALL PLUMBING EQUIPMENT WITH THE ELECTRICAL CONTRACTOR PRIOR TO PURCHASING EQUIPMENT. UNLESS NOTED OTHERWISE, ALL DRAINAGE PIPING SHALL BE SLOPED AT A MINIMUM OF 18" PER FOOT. 2" SANITARY PIPING AND ALL GREASE WASTE PIPING SHALL BE SLOPED AT 14" PER FOOT. EWC SYMBOL SLEEVES THROUGH INTERIOR DRYWALL CONSTRUCTION SHALL BE 26 GAUGE GALVANIZED SHEET METAL. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LOCATIONS FOR EQUIPMENT INSTALLATION PRIOR TO THE SUBMITTAL OF SHOP DRAWINGS. ALL EQUIPMENT AND DEVICES SHALL BE INSTALLED SUCH THAT THEY ARE EASILY ACCESSIBLE AND SERVICABLE. THIS EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO: PLUMBING FIXTURES, WATER HEATERS, VALVES, CLEANOUTS, THERMOMETERS, GAUGES, STRAINERS AND TRAP PRIMERS. DN WHA THESE DRAWINGS ARE DIAGRAMMATIC AND DO NOT REFLECT ALL POSSIBLE PHYSICAL CONDITIONS. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS AND EXACT LOCATIONS OF EQUIPMENT AND FIXTURES. CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS AND SHALL BE FAMILIAR WITH THE SCOPE AND REQUIREMENTS OF THIS PROJECT. ANY DISCREPANCIES OR LACK OF CLARITY IN THE DOCUMENTS SHALL BE IDENTIFIED TO THE A/E PRIOR TO THE SUBMISSION OF PRICING BIDS. WITH A SUBMITTED BID, CONTRACTOR IS ACCEPTING THESE DOCUMENTS AS SUFFICIENT DEFINITION OF THE SCOPE OF WORK, AND ANY ADDITIONAL COSTS BASED ON UNCLARITY OF CONTRACT DOCUMENTS WILL NOT BE CONSIDERED. BELOW GRADE GRADE CLEANOUT SLEEVES SLEEVES SHALL BE PROVIDED WHERE PIPES PASS THROUGH WALLS, FLOORS AND ROOFS. THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE ARCHITECTURAL, STRUCTURAL, CIVIL, MECHANICAL & ELECTRICAL DRAWINGS (AS APPLICABLE) TO ENSURE ALL PLUMBING WORK IS IS COORDINATED WITH PHYSICAL CONDITIONS. PROVIDE NECESSARY OFFSETS, RISES, AND PIPING TO COORDINATE WITH THE BUILDING STRUCTURE, WORK OF OTHER TRADES, AND CONNECT POINTS TO SITE UTILITIES (AS APPLICABLE). B/G GCO GENERAL ALL WORK SHALL COMPLY WITH ALL STATE, CITY AND LOCAL CODES, RULES AND REGULATIONS. CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS AND INSPECTIONS ASSOCIATED WITH THIS WORK, AND SHALL PAY ALL COSTS AND FEES INVOLVED. G HOSE BIBB R HB 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH ABOVE CEILING E A/C GAS PIPING RUN ON ROOF SURFACES SHALL BE ELEVATED NO LESS THAN 312" INCHES ABOVE ROOF SURFACE. PROJECT #: 14-820.00 P000 R O F I C I E N P T peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com R ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID SEAL: 02.07.2014 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH R PROJECT NAME & ADDRESS PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: SCHEDULES PLUMBING PROJECT #: 14-820.00 P001 R O F I C I E N P T 3 2 5 4 7 6 8 peiatl.com 9 G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com R 3 HD-1 22 FCO FD-2 FCO 1 G 18X48 GW 26 FD-2 18x48 4 2 HD-1 2 2 24x60 FD-2 24x60 2 24x60 ISSUED FOR BID TD-1 24x60 S 24x60 ISSUED FOR PERMIT 02-07-14 HB 2 2 2 2 4 24x60 24X60 4 DESCRIPTION: 02-07-14 21X60 FD-2 FD-2 18X48 2 2 ISSUE / REVISIONS: DATE 18x48 DUNNAGE GW 18X48 1 24x48 6 ISSUED FOR CONSTRUCTION DUNNAGE 18X48 6 F.9 18x48 DUNNAGE CD 18x48 DUNNAGE HD-1 H HD-1 20.4 24 18x48 DUNNAGE HD-1 24 24x48 DUNNAGE H 23 24x48 DUNNAGE 1 24x36 DUNNAGE 2 24X36 1 24x48 DUNNAGE J 26 4 18x48 HB 4 4 FCO HD-1 F SEAL: 02.07.2014 14x48 4 GW 2 6"GCO 2A FE GW FCO FD-2 D.9 1 E 4 4 L-1 4 14x60 4 17 9 10 12 UR-1 18 HD-1 S WC-2 8 4 FD-2 FD-1 7 FCO 18 9 22 24x48 B WC-2 24x72 R GW FS-1 WC-1 27 19 C 8 7 25 21 6"GCO FD-2 S CO2 25 24x72 B L-1 25 15 A 5 20 13 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH D 7 WH FD-1 IP 15 2 WH-1 2 FD-2 WH-2 4 FD-2 14x60 4 14x60 6 6 FS-1 14x60 PROJECT NAME & ADDRESS L-1 14 1 P100 1 2 3 FLOOR PLAN - WASTE & VENT 5 4 GI-1 1/4" = 1'-0" 7 6 8 9 PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: KEYNOTES 1 FLOOR PLAN - WASTE & VENT - PLUMBING (THIS PLAN ONLY) 3" HUB DRAIN HD-1 W/3" GW B/F. ROUTE INDIRECT WASTE FROM NEARBY FIXTURE(S) FULL SIZE A/F & DISCHARGE INTO DRAIN W/AIR GAP 2 112" GW A/F TO 2" GW DN & B/F, 2" V UP & A/C 3 112" GW A/F TO 3" GW DN & B/F, 3" V UP & A/C 4 3" P-TRAP B/F AT FIXTURE 5 3" GW B/F TO 3" GW DN, 2" V UP & A/C 6 3" V A/C & DN INTO 3" GW B/F 7 2" V A/C & DN INTO 3" GW B/F 8 3" FLOOR SINK FS-1 W/3" GW B/F. ROUTE INDIRECT WASTE FROM NEARBY FIXTURE(S) FULL SIZE A/F & DISCHARGE INTO DRAIN W/AIR GAP 9 3" V UP TO 3" VTR 10 3" GREASE INTERCEPTOR VENT B/G, UP IN BUILDING & A/C 11 4" V UP TO 4" VTR 12 3" V B/G TO GREASE INTERCEPTOR GI-1 13 6" GW B/G TO 1500 GALLON PRECAST CONCRETE GREASE INTERCEPTOR GI-1 (SEE DETAIL). EXACT LOCATION OF GREASE INTERCEPTOR SHALL BE CLOSELY COORDINATED WITH CIVIL DRAWINGS AND HARDSCAPE. 14 6" S B/G TO SANITARY SEWER, SEE CIVIL DWG FOR CONT 15 4" S B/F TO 4" S DN, 2" V UP & A/C 16 112" S A/F TO 2" S DN & B/F, 2" V UP & A/C 17 (2) 112" S A/F TO 2" S DN & B/F, 2" V UP & A/C 18 3" FLOOR DRAIN FD-1 W/3" S B/F & 12" TP LINE B/F & UP TO TP-'L' 19 2" S A/F TO 2" S DN & B/F, 2" V UP & A/C 20 3" S B/F TO 3" S DN, 2" V UP & A/C 21 3" FLOOR DRAIN FD-2 W/3" S B/F & 12" TP LINE B/F & UP TO TP-'A' (SEE P101 FOR CONT) 22 2" V UP TO 2" VTR 23 1" CONDENSATE DN & DISCHARGE INTO HUB DRAIN W/AIR GAP 24 FULL SIZE CONDENSATE CONNECTION TO FREEZER/COOLER REFRIGERATION EQUIPMENT 25 ROUTE 3" PVC COMBUSTION AIR INTAKE & 3" PVC EXHAUST VENT UP TO WATER HEATER MANUFACTURER'S CONCENTRIC VENT KIT. INSTALL VENT PIPING IN STRICT ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS 28 PROJECT #: 14-820.00 26 A/C RUN VENT A/C AS INDICATED AND NOT A/F IN WALL (TO 27 AVOID CONFLICT WITH PAPER TOWEL DISPENSER). 28 6" S B/G THROUGH SAMPLING MANHOLE TO SITE UTILITY (SEE CIVIL DWG FOR MANHOLE & CONTINUATION) P100 R O F I C I E N P T 3 2 5 4 7 6 8 9 peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com R 22 J 2 BFP-1 7 FWH-1 1 MV-1 22 17 BFP-1 2 17 17 H H 4" 4" 3 3 2 2 4" 4 24x60 24x60 24x60 2 2 24x60 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID HB 15 MV-1,HB-1 28 FW DESCRIPTION: 02-07-14 G 2 2 4 24x60 24X60 1" ISSUE / REVISIONS: DATE 21X60 1" 18X48 2 2 4" ISSUED FOR CONSTRUCTION 18x48 DUNNAGE MV-1 1 24x48 4 18X48 6 18x48 F.9 DUNNAGE 18X48 BFP-1 2 18x48 DUNNAGE 3 16 18x48 DUNNAGE 4" 18x48 DUNNAGE 3 G 3 1" 24x48 DUNNAGE 1" 24x36 DUNNAGE 4" 24x48 DUNNAGE 3 18X48 1 " 2 24X36 20.4 24x48 DUNNAGE G 24x60 1 MV-1 3 HB 3 114" BFP-1 2 4 4 2" FW 1" 2" 4 E 1 " 2 L-1 4 4 (2) MV-1 2" 6 1" CW-1 5 2 WC-1 3 1" 4" 1" 114" C 18 WHA-'B' 19 114" 3 28 3 UR-1 D 2" 3 4" 1" 18 WHA-'B' 4" 1" 9 4" 2" 2" B 12 25 3 2" 4" G 27 WH-1 24x48 7 FWH-1 HWRP-1 3 WC-2 14 TP-'A' 112" 4" 114" 19 5 IP 2 26 WH-1 4 PROJECT NAME & ADDRESS WH-2 4 14x60 6 6 112" 14x60 5 14x60 1" G L-1 R D.9 114" 7 24x72 24x72 CO2 WH-2 23 WC-2 FWH-1 A 3 MV-1 20 13 BFP-1 8 3 10 4" P101 24 2" 11 1 B 21 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH 1" 4" 1 " 2 WH 2 BFP-1 1" SEAL: 02.07.2014 2A FE 14x60 F 28 FW 4 14x48 4 1 " 2 18x48 4 4" FLOOR PLAN - WATER & GAS 1/4" = 1'-0" PROTOTYPE SERIES 1 2 3 4 5 7 6 8 9 70 SL (C) - SDT SHEET TITLE: KEYNOTES 1 1 " 2 2 1 " 2 3 3 4 (THIS PLAN ONLY) CW & 12 MV-1. ROUTE 12" CW & 12 FW A/C & DN TO FIXTURE, PROVIDE BACKFLOW PREVENTER BFP-1 AT FIXTURE CONNECTION CW & 12 MV-1. ROUTE 12" CW & 12 3 4" CW & 12 VALVE MV-1, ONE AT EACH LAV. ROUTE 12" CW & 4" 1 2 5 1 " 2 6 3 7 CW & 12 1 " CW & 1 " CW & 3 4 2 2 HW TO SINK & 3 4" CW & 3 4" HW TO CAN WASH 3 " CW A/C & DN TO FREEZEPROOF WALL HYDRANT 4 FWH-1 @ 2'-0" AFG 4" FLOOR PLAN - WATER & GAS - PLUMBING 8 3 " FW A/C & DN TO BAG-IN-BOX, PROVIDE 4 BACKFLOW PREVENTER BFP-1 AT FIXTURE CONNECTION 9 1" CW INLET & 1" FW OUTLET TO WATER FILTER 10 3 11 3 4 YH-1 AT 4 DUMPSTER PAD (SEE DETAIL). 3 4" CW TO YARD HYDRANT ROUTED DIRECTLY FROM SITE WATER MAIN (SEE CIVIL DWG), FIELD COORDINATE WITH CIVIL. 3 12 112" CW, 112 4 HEATER WH-1,2 (SEE DETAIL) 13 2" GAS DN & A/F TO WALL HUNG INSTANTANEOUS GAS WATER HEATERS, SEE DETAIL 14 1 " 2 CW O/H TO TRAP PRIMER TP-'A', 12" TP LINE DN & B/F 15 3 " CW & 1 2 4 MV-1. ROUTE 12" CW & 12 & 3 4" CW TO HB-1. 16 112" GAS TO MANUAL BALL VALVE AND SOLENOID OPERATED SHUTOFF VALVE. SOLENOID VALVE SHALL BE INTERLOCKED WITH HOOD FIRE SUPPRESSION SYSTEM TO CLOSE WHEN ACTIVATED. 17 3 4" VALVED FLEXIBLE GAS CONNECTION TO GAS FIRED APPLIANCE (SEE DETAIL) 18 1" CW A/F TO WATER HAMMER ARRESTOR IN WALL 19 114" CW A/C, DN & A/F 20 2" CW B/F & UP TO DOMESTIC WATER SERVICE ENTRANCE RISER (SEE DETAIL) 21 2" DOMESTIC WATER SERVICE B/G, SEE CIVIL DWG FOR CONT 22 SCH 40 PVC CONDUIT FROM BAG-IN-BOX. SEE DETAIL 23 NATURAL GAS SERVICE B/G TO SITE UTILITY (SEE CIVIL DWG FOR CONT) 24 NATURAL GAS SERVICE B/G & UP TO GAS METER/PRV INSTALLATION (COORDINATE WITH NATURAL GAS SUPPLIER). REFER TO RISER DIAGRAM FOR DESIGN INFORMATION. 25 NATURAL GAS THROUGH WALL, UP & HOLD TIGHT TO SLOPED ROOF STRUCTURE ABOVE 26 NATURAL GAS UP THROUGH ROOF WITH WATERPROOF PENETRATION (SEE P102 FOR CONT) PROJECT #: 14-820.00 27 SCH 40 PVC CONDUIT TO BEV. DISPENSER (SEE KEYNOTES 22 FOR LOCATIONS) 28 1 " 2 CW A/C W/DOUBLE-CHECK BACKFLOW PREVENTER BFP-2 TO 3-WAY EVAP COOLER VALVE (LOCATED ABOVE CEILING, PROVIDED WITH MAU), FIELD COORDINATE EXACT LOCATION. ROUTE 12" DISCHARGE A/C & DROP IN MOP SINK P101 R O F I C I E N P T peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com R ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID RTU-1 M.A.U. RTU-3 SEAL: 02.07.2014 RTU-4 NATURAL GAS DN THROUGH ROOF WITH WATERPROOF PENETRATION, SEE KEYNOTE 26 ON P101 FOR CONT. 114" GAS ON ROOF TO MAKEUP AIR UNIT (SEE DETAIL) RTU-2 PROJECT NAME & ADDRESS R 3" VTR G G 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH CONCENTRIC VENT KIT FOR WATER HEATER INTAKE/EXHAUST (SEE KEYNOTE 25 ON P100) CONCENTRIC VENT KIT FOR WATER HEATER INTAKE/EXHAUST (SEE KEYNOTE 25 ON P100) 1 P102 ROOF PLAN 1/4" = 1'-0" PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: ROOF PLAN PLUMBING PROJECT #: KEYNOTES 1 3 4" (THIS PLAN ONLY) 14-820.00 GAS ON ROOF TO ROOFTOP UNIT (SEE DETAIL) 2 1" CONDENSATE CONNECTION TO ROOFTOP UNIT WITH P-TRAP & VENT, CONDENSATE DRAIN SPILL TO ROOF P102 R O F I C I E N P T peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com R ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID SEAL: 02.07.2014 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH R PROJECT NAME & ADDRESS PROTOTYPE SERIES 70 SL (C) - SDT SHEET TITLE: DETAILS - PLUMBING PROJECT #: 14-820.00 P200 R O F I C I E N P T peiatl.com G E N G N I N E E R I 3600 Dekalb Technology Pkwy Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com R ISSUED FOR CONSTRUCTION ISSUE / REVISIONS: DATE DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID SEAL: 02.07.2014 SUPPORT FROM STRUCTURE THERMOWELL & THERMOMETER 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH R PROJECT NAME & ADDRESS BALL VALVE PROTOTYPE SERIES AQUASTAT CHECK VALVE STRAINER BALANCING VALVE PRESSURE GAUGE 70 SL (C) - SDT SHEET TITLE: DETAILS - PLUMBING TO WATER HEATER DIELECTRIC UNION ON BOTH SIDES OF PUMP SUPPORT CHANNEL BALL VALVE RECIRCULATED HOT WATER FROM DISTRIBUTION LOOP INLINE HOT WATER RECIRCULATION PUMP, SEE SCHEDULE FOR CAPACITY PROJECT #: 14-820.00 P201 R O F I C I E N P T peiatl.com WASTE/VENT ISOMETRIC NO SCALE G E N G N I N E E R I 3600 Dekalb Technology Pkwy 2"VTR Suite 140 Atlanta, Georgia 30340 p 404.330.9798 www.peiatl.com 2" R 4"VTR TD 2" SK 4" 3" 3" 3" HD 3" 3" 2" FD 3" 3" 3" 3" 2" FD 3" 3" 4" LAV 3"VTR ISSUE / REVISIONS: 4" 2" 6" 3" 6" FCO HD 3" DATE 6"GCO 3" SAMPLING MANHOLE (SEE CIVIL) 6" 3" DESCRIPTION: 02-07-14 ISSUED FOR PERMIT 02-07-14 ISSUED FOR BID FD 6" MS 3" 3" FCO FD 3" 3" 4" 4" FD 2" 3" 2" 3" 2" 2" LAV 4" 2" 4" 2" 2" SK ISSUED FOR CONSTRUCTION 3" 3" 3" 4" 3" 2" 3" 3" 3" 4" 6"GCO 3" FS 3" 4" 3" FD SK 3" HD 3" GREASE INTERCEPTOR 3" 3" 4" FD FD 3" 3" 3" HD SEAL: 02.07.2014 3" WC 2" 4" 4" WC 4" 4" 4" FD 4" 4" 4" UR PROJECT NAME & ADDRESS 2" R 3" FD 3" 3" 2" 3" 2" 3" HD 3" FD 3" 3" 3" 2" 4" 4" HD 2" 3" 2" FCO 2" 4" WC NATURAL GAS RISER DIAGRAM NO SCALE 3 4" RTU (72 MBTU) 3 4" RTU (72 MBTU) 114" (144) 3 4" 114" (72) MAU (179 MBTU) 3 4" RTU (72 MBTU) 3 4" RTU (72 MBTU) 112" (467) 112" (323) 2" (977) 3" (1737) 3 1" (144) 4" (72) ROOF 70 MODEL 2931 WEST MAPLE LOOP DRIVE LEHI, UTAH 3" 2"VTR 3" 3" 3" 2" 3" 3" 3" 3" 3" 2" 3" FD 3" 3"VTR FD 3" 6" 4" 2" 3" SK 2" 2" (510) 2" PROTOTYPE SERIES WH-1 (380 MBTU) 70 SL (C) - SDT WH-2 (380 MBTU) 3 2" (760) 112" (380) 3" 2" (510) 4" FRYER (170 MBTU) 112" (340) 3 4" FRYER (170 MBTU) 114" (170) 3 4" SHEET TITLE: FRYER (170 MBTU) ISOMETRICS & RISERS - PLUMBING GROUND LEVEL GAS METER INSTALLATION: DELIVERY PRESSURE = 10"W.C., TOTAL CONNECTED LOAD = 1737 MBTU. SIZING BASED ON IFGC TABLE 402.4(2) - SCHEDULE 40 METALLIC PIPE, INLET PRESSURE LESS THAN 2PSI, PRESSURE DROP OF 0.5"W.C., 125' T.D.L. PROJECT #: 14-820.00 P300